GOSN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits



Similar documents
GOSB. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection. Ordering Information. Applications. Features & Benefits

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

Fibre Optic Indoor/Outdoor Cable

144Fibre SM (G.652) Loose Tube Micro Lite Duct Optical Fibre Cable PRODUCT INFORMATION

Optical Fibers Fiber Optic Cables Indoor/Outdoor

FIBER-OPTIC CABLES LWL-KABEL

Fibre optic cables MDIC LSZH

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

Discontinued. Volition. Fiber Optic Cable. 3Innovation

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

ESPECIFICACIÓN DE PRODUCTO

OPTICAL FIBER CABLES

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Industry solutions: Broad cast

home site map help ECMS Project: Standard / Federal Oversight Advertised

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Fibre Optic Cable. Catalogue.

ALL-DIELECTRIC LOOSE TUBE FIBER OPTIC CABLE

CAVEL VS80205 MADE IN ITALY 1000 V

SINGLE MODE OPTICAL FIBER FTTH CABLE

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

P URCHASING D IVISION

CHARACTERISTICS AND ADVANTAGES OF OPTICAL FIBER CABLES

Microbend evaluation of selected G652D & G657 fibers and ribbons before cabling

P URCHASING D IVISION

Fiber Optic Specifications

FIBER OPTIC Cables. Cable for Indoor and Outdoor & Hybrid & Marine fiber optic cables

Fiber Optic Cable

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

Design of Ultra-High-Density 2000-Optical Fiber Cable with Pliable 8-fiber Ribbons for Underground Deployment

COAX Cables Radio Frequency Cables

DATA SHEET SERVO LK SMS FX8PLUS SIGNAL

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

with coloured cores and overall copper screen UL/CSA... 17

Quality Reliability Innovation. ISO 9001 : 2000 CERTIFIED BY AFAQ No. QUAL / 1997 / 7034 a COPPER TELECOMMUNICATION CABLES

Plug & Play Universal Systems

Fiber Optic Cordage. Interconnect A Furukawa Company. Product Description. Why OFS Interconnect Cordage?

Optocore Guideline for Fiber Optical Cabling in Permanent Installations

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

The Quality Connection. GigaLine Fiber optic cabling systems for DataCenter Office Industry

part number number Description B96551 M96551 Tactical, All Dielectric Cable, Tight Buffer, Oudoor, Multimode OM1, 62.5 µm, 4 fibers B96566 M96566

Installation Guide OPTICAL FIBRE CABLE

INTERNATIONAL TELECOMMUNICATION UNION #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

7.4 3M No Polish Connector

Reliable, Consistent, Quality

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

FIBER-OPTIC CABLES LWL-KABEL

Polymer Coated Fiber Cable (PCF)

RLH 2 Wire Digital Phone Fiber Link Card System

Commercial Coaxial Cable

MacArtney Underwater Cables - In stock

What are Fibre Optics?

The Quality Connection. Cable Solutions for Mobile Networks Business Unit Telecom

BELFLOW SERIESS FIBER DISTRIBUTION FIBER DISTRIBUTION BELFLOW IS A BOF (BLOWING OF FIBER) SYSTEM DEVELOPED FROM BELCONN.

UC FIBRE Optical Fibre Cable CABLE SOLUTIONS FOR NETWORKS TO LAST

Communication, Signal & Data Cables

Outside Telephone Cable

Fiber Optic Cable Products. Leading Solution

RF cables. Edition 2015

RF & Microwave cable assemblies C291

ETHERLINE Ethernet Cable, Connectors & Tools

FIBER OPTIC CABLE PLANT DOCUMENTATION

Broadcast and Commercial AV Cabling MASTER CATALOG

MV CABLE TYPE C

APR 2016 Rev M

B05: Cable protection and sheathing

Chemical resistance Accidental

EXAMPLE OF RELEVANT STANDARDS

Lecture 3: Fibre Optics

HARTING Ethernet Cabling 8-poles Overview

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

QuickSpecs. Models HP X132 10G SFP+ LC ER Transceiver. HP SFP+ Transceivers (SR, LRM, LR and ER) Overview

Single sub-base valve

The following terms are defined within the context of the fiber optic industry

288 Fiber Ultra-High Fiber Density Micro-Duct Cable with Extreme Operating Performance

Specifying an IT Cabling System

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Gulf Cable & Electrical Ind. Co.

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

SINGLE MODE OPTICAL FIBER CABLE

fiberopt Whirlwind Fiber Optic Solutions product guide Ling Rd. Rochester, NY whirlwindusa. com

VIPERFLEX ELECTRIC CABLE

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools

Panduit 28 AWG Patch Cords Installation Guideline

SECTION FIBER OPTIC CABLE AND ACCESSORIES

Removal of EP SP High Voltage Cable

Flygt flexible cables

Procedure for Cutting and Respooling Fiber Optic Cable

UC FUTURE the solution for data centre cabling. A dependable, fast and always available part of. Draka Datacom Solution

QuickSpecs. HPE OfficeConnect 1410 Switch Series. Overview. HPE OfficeConnect 1410 Switch Series. Models. Key features.

Flexible cables for submersible products

ULTIMATE SNAP-N-SEAL

Plastic Optical Fiber for In-Home communication systems

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Transcription:

GOSN Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1 GOSN102 GOSN104 GOSN106 GOSN108 GOSN112 GOSN116 GOSN124 -OM2 BW GOSN202 GOSN204 GOSN206 GOSN208 GOSN212 GOSN216 GOSN224 -OM3 GOSN302 GOSN304 GOSN306 GOSN308 GOSN312 GOSN316 GOSN324 -OM2e GOSN402 GOSN404 GOSN406 GOSN408 GOSN412 GOSN416 GOSN424 -OM2 BW 500/500 GOSN502 GOSN504 GOSN506 GOSN508 GOSN512 GOSN516 GOSN524 -OM4 GOSN602 GOSN604 GOSN606 GOSN608 GOSN612 GOSN616 GOSN624 9/125 ITU G.655 GOSN702 GOSN704 GOSN706 GOSN708 GOSN712 GOSN716 GOSN724 9/125 ITU G.652D-OS2 GOSN802 GOSN804 GOSN806 GOSN808 GOSN812 GOSN816 GOSN824 Std. plywood reel (non-returnable) Std. delivery length Ø800*475mm 7.65 kg Ø1000*530mm 18.0 kg 2100m ± 100m 4100m ± 100m Applications For outdoor use in structured (data) wiring systems (campus backbone) For outdoor use in networks for telecom, cable TV and/or broadcast. Suitable for direct burial. Easy to install in ducts, tunnels and trenches. Features & Benefits A simple cable construction and consequently more cost-effective up to 24 fibres then multi-tube cables. With standard or improved rodent protection. Predicted lifetime > 30 years. These cables are all dielectric and therefore immune to lightning and electromagnetic interference (EMC-safe), spark-free and require no earthing.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794) 1. Primary coated optical fibres: Ø 250 ± 15 um. 2. Central tube, jelly filled (non-dripping and silicon-free) with up to 24 fibres. Individually colour coded optical fibres: 1 12: red natural yellow blue green violet brown black orange - turquoise pink and white. 13 24: red natural yellow blue green violet brown grey orange turquoise pink and white with rings. 3. Swellable yarns as strength members and for the longitudinal watertightness. 4. Black UV resistant PE outer jacket. Identification: BELDEN OFC cable type number x type of fibre + date-, meter- and P/N marking. Mechanical Data No. of fibres Max. 24 Ø Central tube (mm) 3.3 nom./max. (mm) 5.8 / 6.1 Energy of flame (kj/m) 762 Weight (kg/km) 28 2

Optical Characteristics Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU. European Partnumber Coding, Position 5 Fibre-Type Mode- Field /Cladding Diameter (um) Attenuation average/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off 8 9/125 G.652D OS2 9.2 ± 0.4 125 ± 0.7 1310 1 0.32 / 0.40 0.21 / 0.30 3.5 18 0.2 1260 7 9/125 G.655 8.4 ± 0.6 1 0.25 / 0.30 3.5 8.5 < 0.1 A 1260 Note A- Link design value Characteristics (cabled) Multi-Mode Graded-Index optical fibres according to IEC 60793 European Partnumber Coding, Position 5 Fibre- Type Mode-Field Diameter (um) Attenuati on average/ max. (db/km) Bandwidt h (MHzkm) Ethernet Performance (m) 1GBE 10 GBE Num. Apert. (µm) Refr. Index 1 62.5/125 OM1 62.5 ± 2.5 2.7 / 3.2 0.6 / 1.1 200 275 33 0.275 ± 1.495 1.490 5 OM2 2.4 / 3.0 0.7 / 1.0 82 1.481 1.476 2 OM2 2.3 / 2.8 0.6 / 0.9 1200 82 1.481 1.476 4 OM2e 50 ± 2,5 2,3 / 2,8 0,6 / 0,9 1200 750 2000 110 na 1,481 1,476 3 OM3 2.5 / 3.0 0.5 / 1.0 1500 900 300 1.482 1.477 6 OM4 2.5 / 3.0 0.5 / 1.0 0 900 1.482 1.477 A test report (attenuation) is supplied with each delivery. 3

Mechanical, Physical and/or Environmental Characteristics Requirements Temperature range according to IEC 60794-1-2-F1 Tansport/storage Installation Operation Pulling tension according to IEC 60794-1-2-E1 Long term Short term Bending radii for fibres and tubes Installation/operation Watertightness according to IEC 60794-1-2-F5 Crush resistance according to IEC 60794-1-2-E3 Central tube and cable Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6-30 to + 70 C -5 to + 50 C -30 to + 70 C 700 N 1500 N >25 mm Yes 15000 N/m 10 x ø 15 x ø Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Universal (halogen-free) cables for outdoor and/or indoor use. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 4

Revision Rev. Description Date Init. 02 OM3+ changed to OM4 12/10/09 JW 03 OS2 added 25/11/09 JW 04 Crush resistance increased 29/03/10 SN 05 Diam. Tube changed to 3.3mm 28/10/10 SN Date: 17/02/09 Page 1 of 1 Part Number: Orig.: SN Review: GOSN 5