9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS



Similar documents
Chapter 3.4: HVAC & Refrigeration System

HVAC Efficiency Definitions

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Creating Efficient HVAC Systems

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

How to Build a Data Centre Cooling Budget. Ian Cathcart

REFRIGERATION & AIR CONDITIONING SYSTEM

Glossary of Heating, Ventilation and Air Conditioning Terms

Analysis of data centre cooling energy efficiency

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

MAC-120HE-01 Air-Cooled Chiller

3/29/2012 INTRODUCTION HVAC BASICS

HVAC Systems: Overview

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

2B.1 Chilled-Water Return (and Supply) Temperature B.3 Cooling-Water Supply Temperature / Flow

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Heating & Cooling Efficiency

UNIT 2 REFRIGERATION CYCLE

Characteristics of Evaporators

> Executive summary. Explanation of Cooling and Air Conditioning Terminology for IT Professionals. White Paper 11 Revision 2. Contents.

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Refrigeration Basics 101. By: Eric Nelson

Refrigeration and Air Conditioning with Psychrometry

THE PSYCHROMETRIC CHART: Theory and Application. Perry Peralta NC State University

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

SOLAR COOLING WITH ICE STORAGE

Wet Bulb Temperature and Its Impact on Building Performance

Regency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July Prepared by

Waste Heat Recovery through Air Conditioning System

4. HVAC AND REFRIGERATION SYSTEM

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

HVAC Basic Science - System Capacity

Schedule 3(A) Room Air Conditioners

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

How To Design A Building In New Delhi

Appendix C. Minimum Equipment Efficiency Standards

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

Heating, Ventilation & Air Conditioning Equipment

Design of Cold Storage Structure For Thousand Tonne Potatoes

Legacy Data Centres Upgrading the cooling capabilities What are the options?

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

DOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers

Research on the Air Conditioning Water Heater System

Testing methods applicable to refrigeration components and systems

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE

Central Air Conditioning Plants

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

Guidelines of how to instrument, measure and evaluate refrigeration systems in supermarkets PAU GIMÉNEZ GAVARRELL

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

HVAC and REFRIGERATION

Heat Recovery In Retail Refrigeration

Improving Data Center Energy Efficiency Through Environmental Optimization

WORKING DOCUMENT ON. Possible requirements for air heating products, cooling products and high temperature process chillers TRANSITIONAL METHODS

Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Thermal Energy Storage Strategies for Commercial HVAC Systems

FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate

The HVAC Service Assistant

Model-Based Approach for Optimizing a Data Center Centralized Cooling System

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

How To Design A Refrigeration System

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

STULZ Water-Side Economizer Solutions

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

The Second Law of Thermodynamics

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Defining Quality. Building Comfort. Precision. Air Conditioning

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Energy and Buildings

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

HVAC Calculations and Duct Sizing

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Large Energy Savings Per Installation VFDs for Large Chillers

Benefits of Water-Cooled Systems vs. Air-Cooled Systems for Air-Conditioning Applications

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Field test of a novel combined solar thermal and heat pump system with an ice store

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

SASO 2663 :2014 ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Evaporative Cooling System for Aquacultural Production 1

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Transcription:

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS 9.1 Introduction Air conditioning and refrigeration consume significant amount of energy in buildings and in process industries. The energy consumed in air conditioning and refrigeration systems is sensitive to load changes, seasonal variations, operation and maintenance, ambient conditions etc. Hence the performance evaluation will have to take into account to the extent possible all these factors. 9.2 Purpose of the Performance Test The purpose of performance assessment is to verify the performance of a refrigeration system by using field measurements. The test will measure net cooling capacity (tons of refrigeration) and energy requirements, at the actual operating conditions. The objective of the test is to estimate the energy consumption at actual load vis-à-vis design conditions. 9.3 Performance Terms and Definitions Tons of refrigeration (TR): One ton of refrigeration is the amount of cooling obtained by one ton of ice melting in one day: 3024 kcal/h, 12,000 Btu/h or 3.516 thermal kw. Net Refrigerating Capacity. A quantity defined as the mass flow rate of the evaporator water multiplied by the difference in enthalpy of water entering and leaving the cooler, expressed in kcal/h, tons of Refrigeration. kw/ton rating: Commonly referred to as efficiency, but actually power input to compressor motor divided by tons of cooling produced, or kilowatts per ton (kw/ton). Lower kw/ton indicates higher efficiency. Coefficient of Performance (COP): Chiller efficiency measured in Btu output (cooling) divided by Btu input (electric power). Energy Efficiency Ratio (EER): Performance of smaller chillers and rooftop units is frequently measured in EER rather than kw/ton. EER is calculated by dividing a chiller's cooling capacity (in Btu/h) by its power input (in watts) at full-load conditions. The higher the EER, the more efficient the unit. 9.4 Preparatory for Measurements After establishing that steady-state conditions, three sets of data shall be taken, at a minimum of five-minute intervals. To minimize the effects of transient conditions, test readings should be taken as nearly simultaneously. Bureau of Energy Efficiency 115

9.5 Procedure 9.5.1 To determine the net refrigeration capacity The test shall include a measurement of the net heat removed from the water as it passes through the evaporator by determination of the following: a. Water flow rate b. Temperature difference between entering and leaving water The heat removed from the chilled water is equal to the product of the chilled water flow rate, the water temperature difference, and the specific heat of the water is defined as follows The net refrigeration capacity in tons shall be obtained by the following equation: m x Cp x( t in t Net refrigeration Capacity (TR) 3024 Where m mass flow rate of chilled water, kg/hr c p - Specific heat, kcal/kg o C t in Chilled water temperature at evaporator inlet o C - Chilled water temperature at evaporator outlet o C t out The accurate temperature measurement is very vital in refrigeration and air conditioning and least count should be at least one decimal. Methods of measuring the flow In the absence of an on-line flow meter the chilled water flow can be measured by the following methods out In case where hot well and cold well are available, the flow can be measured from the tank level dip or rise by switching off the secondary pump. Non invasive method would require a well calibrated ultrasonic flow meter using which the flow can be measured without disturbing the system If the waterside pressure drops are close to the design values, it can be assumed that the water flow of pump is same as the design rated flow. 9.5.2 Measurement of compressor power The compressor power can be measured by a portable power analyser which would give reading directly in kw. If not, the ampere has to be measured by the available on-line ammeter or by using a tong tester. The power can then be calculated by assuming a power factor of 0.9 Power (kw) 3 x V x I x cosφ ) Bureau of Energy Efficiency 116

9.5.3 Performance calculations The energy efficiency of a chiller is commonly expressed in one of the three following ratios: 1.Coefficient of performance COP kw refrigeration effect kw input 2. Energy efficiency ratio 3. Power per Ton EER Btu/h refrigeration effect Watt input kw/ton kw input Tons refrigeration effect First calculate the kw/ton rating from the measured parameters. a) kw/ton rating Measuredcompressor power, kw Net refrigeration capacity (TR) Use this data to calculate other energy efficiency parameters with the following relations COP 0.293 EER EER 3.413 COP kw/ton 12 / EER EER 12 / (kw/ton) kw/ton 3.516 / COP COP 3.516 / (kw/ton) * Source : American Refrigeration Institute b) Coefficien t of performance(cop) 3.516 kw/ton rating c) Energy Efficiency Ratio( EER) 12 kw / ton rating 9.5.4 Performance evaluation of air conditioning systems For centralized air conditioning systems the air flow at the air handling unit (AHU) can be measured with an anemometer. The dry bulb and wet bulb temperatures can be measured at the AHU inlet and outlet. The data can be used along with a psychrometric chart (Figure 9.1) to determine the enthalpy (heat content of air at the AHU inelt and outlet) m x( hin hout ) Heat load ( TR) 4.18 x3024 m mass flow rate of air, kg/hr h in enthalpy of inlet air at AHU, kj/kg h out enthalpy of outlet air at AHU, kj/kg Bureau of Energy Efficiency 117

Heat load can also be calculated theoretically by estimating the various heat loads, both sensible and latent, in the air-conditioned room (refer standard air conditioning handbooks). The difference between these two indicates the losses by way of leakages, unwanted loads, heat ingress etc. 9.6 Measurements to be Recorded During the Test All instruments, including gauges and thermometers shall be calibrated over the range of test readings for the measurement of following parameters. Evaporator a. Temperature of water entering evaporator b. Temperature of water leaving evaporator c. Chilled water flow rates d. Evaporator water pressure drop (inlet to outlet) Compressor e. Power input to compressor electrical power, kw 9.7 Example In a brewery chilling system, ethylene glycol is used a secondary refrigerant. The designed capacity is 40 TR. A test was conducted to find out the operating capacity and energy performance ratios. The flow was measured by switching off the secondary pump and measuring the tank level difference in hot well. Measurements data: Temperature of ethylene glycol entering evaporator (-) 1 o C Temperature of ethylene glycol leaving evaporator (-) 4 o C Ethylene glycol flow rates 13200 kg/hr Evaporator ethylene glycol pressure drop (inlet to outlet) 0.7 kg/cm 2 Power input to compressor electrical power, kw 39.5 kw Specific heat capacity of ethylene glycol 2.34 kcal/kg o C Calculations m x Cp x( t Net refrigeration Capacity (TR) in t 3024 13200x 2.34 x( 1 ( 4)) Net refrigeration Capacity (TR) 3024 30.65 TR out ) Bureau of Energy Efficiency 118

Measured compressor power, kw kw/ton rating Net refrigeration capacity (TR) 39.5kW kw/ton rating 1.29kW /TR 30.65 TR 3.516 Coefficien t of performance(cop) kw/ton rating 3.516 1.29 2.73 Energy Efficiency Ratio( EER) 12 kw / ton rating 12 1.29 9.3 Bureau of Energy Efficiency 119

Figure 9.1 Psychrometric Chart Bureau of Energy Efficiency 120

QUESTIONS 1) What is meant by a ton of refrigeration? 2) Define the terms net refrigeration capacity, COP, energy efficiency ratio. 3) What is the relation between COP and kw/ton of refrigeration? 4) How would you calculate the heat load for a room to be air-conditioned? 5) If the power consumed by a refrigerating unit / ton of refrigeration is 2 kw then find energy efficiency ratio? REFERENCES 1. Refrigeration and Air Conditioning by Richard C.Jordan & Gayle B.Priester Prentice Hall of India pvt.ltd. 2. Modern Air Conditioning Practice by Norman C.Harris McGraw-Hill International Edition. Bureau of Energy Efficiency 121