TrueAlarm Fire Alarm Systems



Similar documents
TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

QuickSpecs. HP 200 G1 Microtower Business PC. HP 200 G1 Microtower Business PC. Overview

Chapter 5 Cubix XP4 Blade Server

DMS-10101, Computer Equipment

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Ultra Thin Client TC-401 TC-402. Users s Guide

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay


Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Cisco MCS 7825-H3 Unified Communications Manager Appliance

2100 POS System User Guide

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

Pano Device. Data Sheet. How It Works: Key Benefits:

Audiolog Turnkey Servers

QuickSpecs. HP 280 G1 Microtower Business PC. Overview

USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p

I/A Series HARDWARE Product Specifications

Cisco 7816-I5 Media Convergence Server

ACER INC. VERITON M200 QUICK SPEC

Minimum Hardware Specifications Upgrades

Fire Control Panels Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel

Job Aid Pre-Installation Information S8500 Media Server

v1 System Requirements 7/11/07

Scout 1U Rackmount Computer

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Application Server V240 Platform

Automation Motion Server

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

DCS Data and communication server

System x3650 Type 7979

Cisco MCS 7816-I3 Unified Communications Manager Appliance

USB 2.0 VGA ADAPTER USER MANUAL

HP Advanced Wireless Docking Station. User Guide

Cisco MCS 7825-H2 Unified CallManager Appliance

HQP-1072 Series System User Guide

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

Box PC Fanless. Box PC Performance

Display units With alphanumeric screen

Acer LCD Monitor Driver Installation Guide

LB-IPC. High Performance, Ultra Low Noise Low Power Consumption. Features. Applications

1. Desktop Systems: Given below is the clarification and suggested changes.

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

Network Projector Operation Guide

QuickSpecs. HP 285 Pro G1 Microtower Business PC. Overview

Foxboro Evo Process Automation System

New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

Product Specifications. Shuttle Barebone D10. Shuttle Mini-PC with 7" Touchscreen. Feature Highlight.

Dell Latitude E6320. Setup and Features Information. About Warnings. Front and Back View

System Configuration and Order-information Guide ECONEL 100 S2. March 2009

ViewLinker USB 2.0 Graphics Adapter

How To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X

HP Server Console Switch with Virtual Media Overview

Fusion III v3.6 DVR Series

SecureLinx Spider Duo Quick Start Guide

reflecta Super 8 Scanner

Light Industrial Panel PC

MedInformatix System Requirements

Sedao Ltd. SWEP HD Digital Signage Platform Introduction

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

User Guide USB 2.0 LAPTOP DOCKING STATION WITH VIDEO N2953

QuickSpecs. Models HP Server Console Switches

ZOTAC ZBOX nano User s Manual

LaCie 12big Rack Network

NEC EXPRESS5800/R320c-E4 Configuration Guide

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

Infinity C Reference Guide

Intel Core i processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

DeltaV Virtualization Hardware

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

The next generation of display wall processors has arrived.

CalDigit SuperSpeed PCI Express Card

New SurePOS 700 Front Service Cover features offer secure, reliable front access to the system unit

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

USB 2.0 to DVI External Video Adapter USB 2.0 to VGA External Video Adapter

SOFTWARE TECHNOLOGIES

USB to DVI-I Graphics Adapter CSV-2300D USER S MANUAL

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Monitor Wall 4.0. Installation and Operating Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Life Alarm Fire Alarm Controls

AXIS 262+ Network Video Recorder

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

QuickSpecs. HP IP Console Switches. Overview

Checking the Package Contents. Installing the Printer Software. Connecting. Unpacking the. the Printer. Printer. Attaching

Before You Begin Installing Your Scanner

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

Transcription:

TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control panel status annunciation: Personal computer based annunciator provides a convenient and intuitive maintenance/service interface to display system activity and query history logs Compatible with Simplex 4100ES, 4010ES, 4100U, and 4100 Series fire alarm control panels Computer can be used for other functions when access to the fire alarm control panel is not required (connection to fire alarm control panel is supervised; computer must be running with software active at all times) Agency listed systems are supplied with Windows 7 Professional 32-bit operating system Software compatible with Windows 7, Windows Vista, Windows XP, and Windows 2000 32-bit operating systems Listed to UL Standard 864 and ULC Standard S527* PC Annunciator installation options: Server with Local Client installs on computer connected directly to the host fire alarm panel Remote Clients connect to the server via LAN/WAN Ethernet connections; up to 8 can be simultaneously connected (Agency listing is not applicable for Remote Client operation) General annunciator features: Displays Alarm, Supervisory, Priority 2, and Trouble conditions with numerical tallies for each Displays first and last alarms; different event types have separate visible indicators with a common audible indicator Event logs can be searched and printed View and/or print TrueAlarm status reports and service reports (printing requires an available local or network printer) Ports are available for local printer connections Local Client system operations*: Connects to host panel s password protected login for protected features access; includes automatic logout with selectable logout timing Alarm Silence; System Reset; and Priority 2 Reset Global and individual point acknowledge Set system time and date; and clear event log Individual point access for control or point property revisions WALKTEST system test is supported for service convenience * Refer to page 2 for additional listing details. ULC listed applications provide annunciation only, operator actions are not available. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:195 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use City of New York Department of Buildings MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. PC Annunciator Server/Local Client LAN/WAN Connected Remote Clients LAN/WAN Typical System Event Screen Server PC connects to Ethernet via 4190-6010 Transient Suppressor, mounted on rear of PC RS-232 Connection Fire Alarm Control Panel PC Annunciator System Drawing (4100ES shown for reference) Selectable packaging: Computer is available for desktop or rack mounting and includes keyboard and mouse High resolution LCD monitors: 21.5 (546 mm) diagonal for desktop; 42 diagonal for horizontal wall mount applications; or 19 class 18.5 (470 mm) diagonal with touchscreen for 19 rack; Note: Refer to page 6 for important monitor mounting details Rack mount monitor with touchscreen allows cursor control similar to mouse; press and double press duplicates left mouse button click Description 4100ES/4100U/4100/4010ES Series Simplex fire alarm control panels process and store extensive system status, history, and individual point information for the connected devices. This information is accessible from the panel s information display. However, with the addition of a PC Annunciator connected to the host panel, the convenient and familiar Microsoft Windows operating system interface provides a more convenient and powerful access to this information for review, limited control, and report generation and printing. S4190-0013-26 12/2014

Connection Options Local Client. A Local Client application is configured on the same computer as the Server and provides a password protected feature set (ULC listed systems provide annunciator only (restricted) features without operator actions). The computer is directly connected to the host control panel. (Note: A computer configured as a Server only without a Local Client is for connection only to Remote Clients. The Server application alone does not provide PC Annunciator features.) Remote Client. 4190-5040 Remote Client applications provide standard annunciator operation (no control available). Connection Options (Continued) Connection Status Indications. Remote and Local Clients advise at their computer when connection to the Server is unavailable. Loss of communications to the Server is annunciated at the host panel. Additional Reference Description Applications Software 4190-5040 Document Installation 579-492 Operating 579-493 Quick Operation Reference, either software 579-880 LAN Connection Suppressor Installation Instr. 579-900 Product Selection (see below for additional listings requirements) Category Model Description 4190-8201 PC Annunciator with hardware; select Applications Software, computer, and monitor below System Type PC Annunciator software only (listings are not applicable with software only); computer 4190-8602 hardware and operating system supplied separately; select Applications Software below; Applications Software Select One per Local or Remote Client; includes dongle and dongle support software (Security Service) for One Client License (dongle is not required to operate Server function) Computer Type (select one) Transient Suppressor for LAN/WAN Connection 4190-5040 4190-7017 Desktop With 4190-8201, Pre-installed in Hardware; provides PC Annunciator Server and a Local Client with password protected features (Annunciator with Control for Local Client); see additional listings reference below; ULC listed Local Client is Annunciator only With 4190-8602, Software Only (listings are not applicable with software only); can be installed as one of the following: 1. PC Annunciator Server only (no dongle required). 2. or PC Annunciator Server with Local Client providing password protected features (annunciator with control), requires dongle. 3. or Remote Client Annunciator (restricted) features, requires dongle. 4190-7018 Rack Mount 4190-6010 Computer with Intel i7, 2.10 GHz CPU, 6MB Cache, 4GB RAM, (2) 1TB Hard Drives (minimum) with RAID 1 Controller, DVD R/W, integral audio and amplified speakers, onboard video for up to two displays (1) SVGA and (1) DVI, 2 RS232 Serial ports, 6 USB ports, 1 PS/2 port, dual Gigabit LAN, Passive backplane with (8) PCI, (3) PCIe x 1 and (1) PCIe x 16 slot, keyboard, and mouse; charcoal grey housing Computers are pre-installed with Windows 7 Professional (includes CD and license) and with PC Annunciator software. Required for agency listing per Listings Requirements below; recommended for each PC Annunciator Remote Client LAN/WAN computer connection; mounts on rear of PC frame LCD Color Monitor (select one) 4190-7131 21.5 (546 mm) diagonal for desktop applications; black housing 4190-7234 18.5 (470 mm) diagonal for 19 wide rack mount, with touchscreen; black housing; Note: Refer to page 6 for important monitor mounting details 4190-7114 42 (1049 mm) diagonal for horizontal wall mount applications; black housing Note: Equipment may vary due to computer design changes. Contact your local Simplex product supplier for exact equipment specifications. Listings Requirements System Type 4190-8201 with hardware Application Software 4190-5040 Listings* Software Installation* Equipment UL, ULC, CSFM, FM, & MEA As listed above* Computer and monitor selected from above; also requires 4190-6010 Suppressor for Server to LAN/WAN connection 4190-8602 software only 4190-5040 Not Applicable Compatible office quality computer and monitor (refer to computer specifications reference on page 4); select computer and monitor appropriately listed for business/consumer use * NOTE: For ULC Listed applications, the Local Client provides Annunciation Only, operator actions are not available (restricted features only). 2 S4190-0013-26 12/2014

System Screen Details (event window is shown reduced, it can be maximized if desired) Event Screen Details 3 S4190-0013-26 12/2014

Equipment Specifications Computers and Accessories (Please note that equipment and specifications may vary due to equipment design changes) Model* Description Dimensions AC Power Input* 4190-7017 Desktop Computer 4190-7018 Rack Mount Computer NA Rack Mount Keyboard Tray (included with computer) LCD Monitors** (see below and page 2 for additional details) 16 ⅞ W x 7 H x 17 ⅝ D (429 mm x 178 mm x 448 mm) 19 W x 7 H x 17 ⅝ D (483 mm x 178 mm x 448 mm) 19 W x 1 ¾ H x 12 ¾ D (483 mm x 44 mm x 324 mm) 2 A @ 120 VAC, 60 Hz (240 W) Operating Range: 95-132 VAC; 180-264 VAC, auto-range; 50/60 Hz Model* Description Dimensions AC Power Input* Supplied Video Cables 4190-7131 21.5 Desktop 4190-7234 4190-7114 18.5 Rack Mount with Touchscreen 42 Horizontal Wall Mount 20 3 16 W x 15 H x 6 ¾ D (513 mm x 381 mm x 171 mm) 17 ¾ W x 11 1 16 H x 2.022 D (451 mm x 281 mm x 51.4 mm) Note: Refer to page 6 for important monitor mounting details 41 5 16 W x 25 ¼ H x 5 D (1049 mm x 641 mm x 127 mm) 0.4 A @ 120 VAC, 60 Hz (48 W) Operating Range: 100-240 VAC, 50/60 Hz 1.5 A @ 120 VAC, 60 Hz Operating Range: 100-240 VAC, 50/60 Hz 2.02 A @ 120 VAC, 60 Hz (243 W) Operating Range: 100-240 VAC, 50/60 Hz NA (1) DVI and (1) SVGA, 6 ft (1.8 m) long (1) DVI and (1) SVGA, 15 ft (4.57 m) long * Computers and monitors are shipped with 120 VAC cord; NEMA 5-15P plug to IEC-320 C-13 connector. For use with other voltages, locally obtain a cord in compliance with local safety standards. 4190-7017 and 4190-7018 Computer Minimum Specifications Reference** Enclosure Computer Passive backplane with: 7 PCI slots, 2 ISA slots, and 1 CPU slot; security features: key lock reset switch; fan monitor card; locked door protecting access to the CD/DVD R/W drives and two front mounted USB ports Compatible with Microsoft Windows 7, Windows Vista, or Windows XP 32 bit operating system, 2.8 GHz CPU with 2 GB RAM (or Core 2 Duo 2.1 GHz CPU with 4 GB RAM), 40 GB minimum hard drive; 2 Serial ports, 1 Parallel port, 4 USB ports, dual Gigabit LAN, 1 PS/2 mouse port, 1 PS2 mouse & keyboard adapter cable; SVGA video output with 16 MB VRAM, CD/DVD R/W, 101 key keyboard, PS/2 mouse, PCI and ISA slots (as required) ** PLEASE NOTE: Simplex 4190 Series computers are Agency listed for use with PC Annunciator software. For applications where Agency listings are not required, PC Annunciator software should be compatible with most computers meeting the stated minimum specifications. However, due to computer manufacturers potentially using unique and/or proprietary drivers, hardware, or other software not tested with PC Annunciator software, there may be incompatibilities. If other computers are used, proper operation with PC Annunciator software may require technical adjustments by a qualified computer technician and would be the sole responsibility of the computer supplier and computer manufacturer. Computer Port Reference RS-232 Serial Ports USB Serial Ports Ethernet Ports Parallel Port Printable Information Printer Compatibility Two available; one is required to connect to Port B of the fire alarm control panel 4 total; 2 in the rear (one is used for Server Security Dongle), and 2 in the front behind the locked door Two available; one is required for Ethernet connection to Remote Clients One available Historical log reports, TrueAlarm Service Reports, and System Activity Reports Agency listed printer 4190-9013 is recommended (see data sheet S4190-0011); other serial or parallel port printers per operating system compatibility Environmental Specifications Operating Temperature 32 to 120 F (0 to 49 C) Operating Humidity up to 93% RH, non-condensing, at 90 F (32 C) 4 S4190-0013-26 12/2014

Desktop Hardware Reference 6-3/4" D (171 mm) 20-3/16" W (513 mm) 17-5/8" D (448 mm) 15" H (381 mm) 16-7/8" W (429 mm) 7" H (178 mm) PC Annunciator CPU 42 Wall Mount Monitor Reference 5" D (127 mm) 41-5/16" (1049 mm) 25-1/4" H (641 mm) 5 S4190-0013-26 12/2014

Rack Mount Hardware Reference with 18.5 Monitor Rack equipment is supplied separately 18.5" LCD Monitor with Touchscreen reference for monitor for 18.5" dimensions screen 1/4 turn fasteners PC Annunciator CPU 1/4 turn locking fasteners (right side only) Keyboard tray Monitor mounting plate Monitor Detailed Side View Monitor 12-7/32" (310 mm) Monitor extension from back of mounting plate = 2.022" (51.4 mm) NOTE: The monitor mounting plate attaches to the rack mounting rail and the monitor will extend 2.022" (51.4 mm) from the front of the mounting rail. Review the specified rack enclosure to determine actual monitor extension beyond the rack frame and to ensure that a rack door (if used) has adequate clearance. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Microsoft, Windows, and Vista are trademarks of Microsoft Corporation in the United States and/or other countries. Tyco Fire Protection Products Westminster, MA 01441-0001 USA S4191-0013-26 12/2014 www.simplexgrinnell.com 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.