Arcus-EDS Product Description LCD-Color-Display



Similar documents
Functions module / Gateways. KNX-GW-RS232-RS485 Product Group 1

Inwall 4 Input / 4 Output Module

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

KNX Gateway RGK E-01

Inwall Room Temperature Unit

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

How To Use A Power Supply On A Powerline 2.2 (Ai)

Operating instructions. RCD flat 4-fold, 6-fold

Passion for Innovation

KNX/EIB Product documentation. Master Control. Issue: x. Order-No X Page 1 of 222

Push button 3gang standard flush-mounted xx

UM-X Field display for continous level sensors

Block 3 Size 0 KB 0 KB 16KB 32KB. Start Address N/A N/A F4000H F0000H. Start Address FA000H F8000H F8000H F8000H. Block 2 Size 8KB 16KB 16KB 16KB

IDDERO HCx-KNX TOUCH PANELS. Quick start guide

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Tebis application software

HERZ-Thermal Actuators

Busch-Watchdog Presence EIB Type:

Product and Application Description

Niko Home Control. Installation Manual

ABB STOTZ-KONTAKT GmbH. ABB i-bus KNX Weather Unit, Weather Sensor

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

ABB i-bus EIB Logic Module LM/S 1.1

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

User Manual. Humidity-Temperature Chart Recorder. Model RH520

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Electronic Control Devices The European Product Catalogue 2007

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

FLOOR INDICATORS CATALOGUE 2007

Wind Sensor W-RS485 with RS485 Interface

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

RRV934. Multi-controller. Synco living

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

FB-500A User s Manual

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

User's Guide. Integrating Sound Level Datalogger. Model Introduction

FLOOR INDICATORS CATALOGUE 2007

Workshop 7 PC Software - Tracker

ABB i-bus KNX i-bus Tool Product Information

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Quick Start Guide. From setup to gameplay. Basic Setup. Configuring Your System. Using Game Discs IMPORTANT INFORMATION

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Passion for KNX innovation

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Tiny Audio C3. English TINY AUDIO C3. Please read carefully before using this product

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Web:

Ash Capture Control User Guide

MODULAR JUNCTION BOX MJB WITH GATEWAY

L5354 ControlNet Communications Interface

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

User manual LCD 240-2xx

overview DyNet over RS485

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Eelectron srl, Via Magenta 77/22, I Rho (MI), Italia

KNX Panasonic Air Conditioners

OZS Web server. For LPB/BSB plants

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

VENTIsupport Version 1

Infrarot-Bewegungsmelder IP44

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

HyperAccess Access Control System

FLOOR INDICATORS CATALOGUE

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

PRODUCT MANUAL. InZennio Z38i. KNX Touch Panel ZN1VI-TP38i. Program version: 2.2 Manual edition: a

Quick Connect. quick - simple - efficient.

Lab Experiment 1: The LPC 2148 Education Board

PM1122 INT DIGITAL INTERFACE REMOTE

User and installation manual

Keep it Simple Timing

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

How To Use The Dc350 Document Camera

USER S MANUAL Kodiak Series Wireless Trail Camera

Scan2CRM for ACT! User Guide

VIDEO DOOR PHONE SYSTEM

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

PCAN-ISA. CAN Interface for ISA. User Manual

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

IntesisBox KNX LG Air Conditioning

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

KNX Interface. User Manual PM00A00IRI

MARTECH SPI Tools. MARTECH SPI Tools User Manual v1.0. User Manual

Light scene push button 8gang comfort flush-mounted xx

User Guide. Temperature and Humidity Datalogger. Model 42280

USB-500/600 Series Low-Cost Data Loggers and Accessories

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

Transcription:

Arcus-EDS Product Description 010

,, Article Nr: 200111xx (x: 0=without panel; 3=with V2A-panel) (x: 1=white; 2=anthracite) The LCD Display communicates with different devices of the modern electric installation via the KNX/EIB-bus. The LCD Display is used for operating, displaying, monitoring and reporting in EIB/KNX systems. anthracite with V2A panel The visualisation of the functions and the content of the pages can be configured completely free. So every installation can be arranged according to the customer s options. A rotary control button leads through the menu and allows not only to switch easily but also to set up analogue values as e.g. temperature, brightness or volume. Areas of application: white - Switching and Dimming of the lighting with V2A panel - Display of the switching status in the house - Recording and recalling of light scenes - Switch-on, and -off of various devices - Manipulation of jalousies, also with extensive functions - Alarm functions, acoustical and optical, with text indicator - Alarm display of motion detectors with text indicator - Display and setting up of the heating control - Title selection and volume adjustment in Multiroom-plants - Display of outdoor and indoor temperature, time and date. - Direct recalling and setup of the internal clock timer - Representation and recall of system-resident JPG-pictures, e.g. access control - Protection of pages with Pin-Code (e.g. for the heating control) - Display of the temperature run within the time using a diagram (Forth-program) - Metering and display of the cycle time of the electric devices in bus - Logical and/or functions The LCD Display is compatible with most series of switch programs with a frame of 55x55 mm. (e.g. Gira, Jung, Merten) and is mounted onto a standard box. No external electricity is needed. Start-up and parameterization with the graphic java-based softwaretool ArcSuite through a mini-usb cable. See actual project under www.arcus-eds.de/downloads or www.arcus-eds.de/forum. Technical Data: Software ArcSuite: - Java based PC-Software for projection of the, Download www.arcus-eds.de - LCD Display is programmable via USB-port -2-

Hardware: - LCD-Color Display: 160x128 Pixel, BxH 37 x 30mm, 48mm diagonal - 50 MHz Arm7-Processor (256kByte internal memory) for quick 32-Bit integer operations and 64-Bit floating point calculations - 128 kbyte memory size for use e.g. 24 JPG-images for one project - Piezo-signaler for alarm messages - Rotary control button with detent for input and navigation - Adjustable LED background-lighting Graphic and Software: - Free design of page contents - 32 elements can be defined free in size and position - The number of pages is limited only by the internal memory space (31kB), more then 20 sites are possible - Different character fonts, font sizes, editable fonts - Attachment of jpg-graphics as background picture for representation elements - Freely programmable surfaces and text elements - Assignment of pictures as value elements, assignment of text as value elements - Switch-key/push button, turning dimmer, value display, list display of values and text, horizontal and vertical value bars - Value bars adjustable turning the rotary button (number and size of steps adjustable) - Setting of system-values on the display (brightness, contrast, system-date, system-time, standby-time) - Pages directly callable by a button (compilation of the menu), hiding of pages - Setup of a freely definable Pin code to protect pages - Display of HVAC-Icons (Heating, ventilation and air-conditioning icons) Special applications: - With the additional programming language Forth can be generated independent elements - Programmable day-, and week-clock timer, KNX-datapoints and arrangements can be recalled by the clocktimer - Setup of a freely definable scene-generator with memory function in KNX-Modus, different KNX-datapoints can be recalled with a button with their respective values and be recorded - About user functions can be generated independent objects, which are not provided as e.g. special switches, logical functions or graphical applications (diagrams) - Extensive operating element (jalousie switch-key), every operating sequence can be associated to different group addresses - Integrated temperature and humidity recording (only with additional module in standard 55mm) - Alarms KNX-elements: - Up to 128 group addresses through polling with start - 17 EIS-types incl. 14byte ASCI-character string - Listening group addresses - Filtered acceptance of group addresses from the ETS - Direct dimming function with rotary control button, dimming through stop telegram - Buttons (1bit) as switch or key elements with stop telegram - System time/system date - Brightness, contrast and background lighting adjustable by KNX-object - All KNX-types callable as alarm function - Acoustic alarm freely programmable Affixing: - Connection and supply: directly on the KNX-bus, DC 24 V, ca. 10mA, no auxiliary supply necessary - No Bus-Coupling necessary - USB-port on the side (covered by the design frame) - Fittings to a standard flush-mounted box with a simple, or multiple frame of various switchprogram manufacturers (not included in delivery) - Environment temperature: Storage -5...+60 C, Operating -5...+55 C - Measurements: W x H x D, 55 x 55 x 22 mm without design frame - Protection: IP 20 - Colours available: white, anthracite, white with V2A-panel, anthracite with V2A-panel, on request also special colours possible - Delivery incl. supporting frame, USB-cable and ArcSuite Software - Start-up with the ArcSuite Projection-Software -3-

Application area: To bond further components and functions the is provided with a plug contact for the product relevant databus and the necessary software. To this plug contact can be connected various sensors of the Arcus-EDS program. This extension permits to combine economically to the display a temperature-humidity sensor and a dual binary interface. The main components of a simple room control system can be integrated in a triple switch combination. As an accessory module can be allocated the Temperature-Humidity Sensor SK03MV-TF-I in 55mm standard. This sensor will display a temperature and a humidity value to and send it as object to the bus. Programming and setting will be effected with ArcSuite. Connect the Temperature-Humidity Sensor SK03MV-TF-I with the provided 20 cm long ribbon cable. The does not include HVAC-Functions for heating control. You can generate these functions using the Forth-program in, or utilize the SK03-TFK-I as independent TH- Sensor with integrated HVAC and KNX-bus-coupling. Potential-free Contacts: Additional to the temperature-humidity measurement, the SK03MV- TFB2-I disposes of 2 binary ports to analyze switch settings (potential-free contacts). white with Gira frame glasprogram, Below: Lateral view -4-

SK03MV-TF-I, Temperature-Humidity-Sensor The SK03MV-TF-I is a temperature-humidity-sensor, connected to the by the product relevant bus. The high-grade sensor and its separated mounting from make it possible to obtain a high accuracy and short reaction-time. For the requested switch program the SK03MV-TF-I and the can be integrated both together in a double- or multiple-frame-combination. It is available in the colours white, or anthracite, with 55mm profile. The TF-Sensor SK03MV-TF-I connected with MicroVis II logic+ presents an economic variant for temperature and humidity recording. SK03MV-TF-I white The start-up is effected in using ArcSuite. The measured variables, temperature and humidity, are recorded and displayed as KNX-objects to the bus by. The allocation of group addresses and parameters are set with ArcSuite. As adjustment parameters you determine offset, the period of data transmission and transmission by value changes. The SK03MV-TF-I does not provide independent HVAC nor deduced values. Additional functions as Min/Max-Alarm, Continuous or HVAC can be generated using the Forth-program in. As a service can you purchase from Arcus-EDS Forthprograms, controllers or other elements customized for your application. SK03MV-TF-I anthracite with MicroVisII logic+ -5-

Installation MicroVis Installation MicroVis MicroVis, simple frame Gira E2, supporting frame, flush-mounted box The MicroVis is delivered with a supporting frame to fit on a 68 mm flush-mounted box, a USB-cable and a software-cd. The MicroVis can be integrated in every switch program with 55 mm profile. Make an optic test of the combination of your preferred frame model with our MicroVis before fitting. USB- and KNX- Connection Programming MicroVis via USB-Kabel (left), EIB-connection (right) The USB-cable is stuck from underneath directly on to the circuit board with a KNX-clamp. The display can then be clicked into the box with the suitable single frame. To connect the USB-cable, pull the display lightly out of the socket from the upper side. It is not necessary to interrupt the KNX-connection. -6-

Imprint: Publisher: Arcus-EDS GmbH, Rigaer Str. 88, 10247 Berlin Responsible for Content: Hjalmar Hevers, Reinhard Pegelow Reprints, including partial reprints, can be made only with expressed permission from Arcus-EDS GmbH. This information is the best to our knowledge and is without guarantee. We reserve the right to make any technical and price changes at any time. Liability: Selection and determining the appropriateness of the devices for a designated purpose is the customer s full responsibility. We offer no liability or guarantee for this. The data in the catalogue and data sheets is a result of experienced measurements and does not embody a guarantee of particular features. Arcus excludes responsibility for damage done on the part of the customer due to improper operation/projecting or malfunctions. On the contrary, the operator/projector must know that improper operation, and projection and malfunctions do not lead to any further damage. Safety Guidelines: Attention! Installing and assembling electrical devices must only be done by an electronics specialist. The customer should be aware of and adhere to the safety guidelines of VDE, TÜV and the appropriate energy provider. Our guarantee does not include defects and damage caused by improper use or noncompliance of operating instructions. Warranty: We provide a warranty as required by law. Please contact us in case of malfunction and send the device with a full description of the fault to the address below. Manufacturer: Registered Trademarks: The CE Trademark is an unofficial market trademark used exclusively by authorities and provides no warranty of properties. Registered Trademark of Konnex Association -7-