Split Controller. User Manual SM-SS-F 2009/01/04



Similar documents
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

1 General information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

WATER SOURCE / GEOTHERMAL COOLING HEAT PUMP

ELECTRIC CENTRAL HEATING FLOW BOILER

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Problem / Solution. The problem:

Failure code manual. content

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Technical data. Danfoss DHP-A

Smile. The All-In-One Heating Controller

HERZ-Thermal Actuators

Aerona Air Source Heat Pumps

ALL IN ONE. Heat Pump Water Heater

Contents. Introduction

RRV934. Multi-controller. Synco living

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Air conditioning, electrical testing

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Diesel Generating Set

Solar Hot Water Heaters

1. Safety information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Energy Communication Unit (ECU)

RAINCONTROL LCD Special

Electric Flow Boiler

Nexus FS Point of Use Installation Guide

Thermo Top - Troubleshooting Tree

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

NeoGate TA Series Quick Installation Guide

User manual. Atec. 086L0130 Rev. 1 EN

EK908FHL - Thermostat for floor heating

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

User manual. Solid (FR 98,),

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

Heating, air-conditioning, cooling

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

USER S MANUAL HSC-24A

T5000 T000 LCD Digital Fan Coil Thermostat

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Bubble King. User Manual

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Overheating limit control

NX Series Inverters. HVAC Pocket Programming Guide

Inductive Proximity Sensors

Electronic Pressure Switch EDS 300

Neuton Solar Power Diverter Quick Installation Guide

UM-X Field display for continous level sensors

Heating, cooling and irrigation system for a house. Control with two controllers TS-55T + 2 depending on the seasons. option 1 Functional scheme

HEAVY DUTY STORAGE GAS

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Contents. Operation manual of solar water controller SR868C8/SR868C8Q

COOLING HEAT PUMP. China Palm A/ C & Equipment Co., Installation and Operation Manual. -Close Loop Series

Energy Communication Unit (ECU)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Technical Information

Electronic Control Devices The European Product Catalogue 2007

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V

NeoGate TA Series Installation Guide

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

User manual. 086U6297 Rev. 9 EN

Operating Instructions

Controls for fan coil units and cassettes

Electro-Pneumatic Bus Door Control Mechanism

SWIMMING POOL HEAT PUMP Owners Manual

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Installation and Service Instructions for use by heating contractor SM1 SOLAR CONTROL MODULE IMPORTANT

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Data sheet ECC 12 and 22

evohome Wireless Radiator Zoning Kit Installation & User Guide

ALARMLINE ANALOGUE Linear Heat Detection System

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Mode Switch. Fan Switch Menu button Program button

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

ECOplus Solar Cylinder

Instruction manual for models:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Heating Controller. Building Technologies HVAC Products

IntelliTouch Remote Control & Monitor for Service Professionals. User s Guide. ScreenLogic Wireless Connection Kit Installation Guide

Heat Pump. Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175

Zenith Solar thermal 4.5m pump station Installation manual

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

GL-235 Solar Pool Controller

VFS24/32HDIP. Public Display IP Monitor User Manual

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Transcription:

Split Controller SM-SS-F User Manual 2009/01/04

Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed clamp. 4 4.2 Assemble the fixed clasp 5 5. Panel illustration 6 5.1 Controller....6 5.2 Screen....7 5.2.1 Normal screen.. 7 5.2.2 Menu screen.. 7 6. Function..8 6.1 Temp Query...8 6.1.1 Menu schematic diagram.8 6.1.2 Illustration of menu.. 8 6.2 System Set...9 6.2.1 Menu schematic diagram.9 6.2.2 Illustration of menu.. 9 6.3 TD Set.. 10 6.3.1 Menu schematic diagram.10 6.3.2 Illustration of menu.. 10 6.4 HWP Set...11 6.4.1 Menu schematic diagram....11 6.4.2 Illustration of menu... 11 6.5 Heating Set 12 6.5.1 Menu schematic diagram.....12 6.5.2 Illustration of menu...12 6.6 HT Set...13 6.6.1 Menu schematic diagram..13 6.6.2 Illustration of menu... 13 6.7 AF Set... 14 6.7.1 Menu schematic diagram..14 6.7.2 Illustration of menu...14 6.8 Ste Set..15 6.8.1 Menu schematic diagram..15 6.8.2 Illustration of menu...15 6.9 Function icon..16 7. Operation (An example).17 7.1 How to choose auto mode of heating function..17 7.2 How to set parameters of auto mode...18 7.3 How to change the important parameters.19 7.4 Convenient usage of button.20 7.5 Convenient usage of button.20

1. Parts illustration Name Figure Illustration Controller host For Controller Controller packing list For Controller For power cord Fixed clamp For sensor signal line Fixed clasp For controller Power cord P1 For solar pump Screw For fixed clamp For fixed clasp T1 For T1 Sensor T2 T3 For T2 For T3 T4 For T4 User manual For controller - 1 -

2. Electrical technical data NO. Name Specification 1 Size of controller 120mm 165mm 45mm 2 Ambient temperature of controller -20 ~50 3 Protection type of controller IP40 4 1 PT 1000 sensors of collector -20 ~200 (±1 ) (PVC cable) 5 2 NTC 5K sensor of tank -20 ~120 (±1 ) (PVC cable) 6 1 NTC 5K sensor of hot water pipe -20 ~120 (±1 ) (PVC cable) 4 Power supply of controller AC110V±10% AC220V±10% 60Hz 50Hz 8 Power consumption of controller 9 Power supply of solar pump 10 Power consumption of solar pump 2W (AC110V±10% 60Hz) 2W (AC220V±10% 50Hz) AC110V±10% 60Hz AC220V±10% 50Hz 250W (AC110V±10% 60Hz) 250W (AC220V±10% 50Hz) 11 Power supply of circulating pump AC110V±10% AC220V±10% 60Hz 50Hz 12 Power consumption of circulating pump 13 Power supply of electric heating device 14 Power consumption of electric heating device 250W (AC110V±10% 60Hz) 250W (AC220V±10% 50Hz) AC110V±10% 60Hz AC220V±10% 50Hz 2000W (AC110V±10% 60Hz) 3000W (AC220V±10% 50Hz) - 2 -

3. Electrical connection T1 T2 T3 T4 P2 P1 L1 N1 L N Symbol Specification Symbol Specification T1 Collector sensor L1 T2 Tank lower sensor N1 T3 Tank top sensor L T4 Hot water pipe sensor N Electric heating device Power supply P1 P2 Solar pump Circulating pump Earthing - 3 -

4. Assemble parts 4.1 Assemble the fixed clamp - 4 -

4.2 Assemble the fixed clasp - 5 -

5. Panel illustration 5.1 Controller 3 4 2 1 NO. Button Normal Screen Menu Screen 1 Into the menu screen Confirmation 2 Into the menu screen Return 3 Into the heating set 4 Into the system set Move up cursor Increase parameter value Move down cursor Decrease parameter value - 6 -

5.2 Screen 5.2.1 Normal screen 1 2 3 4 NO. Illustration 1 Time 2 System schematic diagram 3 Designated sensor temperature 4 Function icon 5.2.2 Menu screen Heating Set 1 / 3 Manu Mode Auto Mode 1 2 3 4 5 NO. Illustration 1 Main menu 2 Cursor 3 Sub menu 4 Selected function icon 5 Allowed operation icon - 7 -

6. Function 6.1 Temp Query 6.1.1 Menu schematic diagram T1:100 Good Temp Query T2: 80 Good T3:--- Short T4:--- Open 6.1.2 Illustration of menu Menu Description Temp Query Query the temperature and working state of sensors T1 Collector sensor temperature T2 Tank lower sensor temperature T3 Tank top sensor temperature (Factory setting: T3) T4 Pipe sensor temperature Good Sensor normal operation Short Sensor Short circuit Open Sensor open circuit Designated the sensor temperature will be shown in the normal screen When the sensor failure occurs, will be shown in the normal screen and flicker. - 8 -

6.2 System Set 6.2.1 Menu schematic diagram Language/ 语 言 中 文 English Time Set 00:00 System Set Brt Set 5 Set Restore SN 080010001 6.2.2 Illustration of menu Menu Description System Set Set the basic parameters of system Language/ 语 言 Choose English or Chinese (Factory setting: English) Time Set Set the time Brt Set Set the brightness contrast Range: 0~9 (Factory setting: 5) Set Restore All parameters returned to the factory setting SN Query the serial number - 9 -

6.3 TD Set 6.3.1 Menu schematic diagram ON ON Set:10 Set: 5 TD Set 6.3.2 Illustration of menu Menu Description TD Set Temperature difference circulation ON On temperature difference circulation function (Factory setting: ON) Off temperature difference circulation function ON Set Set the temperature difference for start solar pump (P1) Range: 6 ~20 (Factory setting: 10 ) Set Set the temperature difference for stop solar pump (P1) Range: 2 ~10 (Factory setting: 5 ) When the temperature difference circulation function is ON, will be shown in the normal screen. And when the solar pump is operated, will flicker. - 10 -

6.4 HWP Set 6.4.1 Menu schematic diagram Tank Top :40 Temp Set Pipe Upper:38 Temp Mode Pipe Lower:30 1 04:00-05:00 Time Set 2 HWP Set 3 17:00-22:00 Temp Set Tank Top :40 Time Mode * 6.4.2 Illustration of menu Menu Time Set 1 04:00-05:00 2 3 17:00-22:00 Description HWP Set Hot water pipe circulation Temp Mode Temperature control mode Time Mode Time control mode * hot water pipe circulation function (Factory setting: ) Temp Set Set the temperature for start or Stop circulating pump (P2) Time Set Set the time period for start or Stop circulating pump (P2) Tank Top Tank top sensor temperature Range: 20 ~60 (Factory setting: 40 ) Pipe Upper Pipe upper limit temperature Range: 20 ~45 (Factory setting: 38 ) Pipe Lower Pipe lower limit temperature Range: 20 ~45 (Factory setting: 30 ) 1 04:00 05:00 2 3 17:00 22:00 Three time period of user defined. The time period will be, if they are the same. (e.g. 08:00 08:00 ) When the Temp Mode is chosen, will be shown in the normal screen. And when the circulating pump is operated, will flicker. When the Time Mode is chosen, will be shown in the normal screen. And when the circulating pump is operated, will flicker. - 11 -

6.5 Heating Set 6.5.1 Menu schematic diagram Manu Mode Temp Set Temp:60 Temp Set ON Temp:40 Temp:60 Heating Set Auto Mode 24H ON 24H Time Set 1 04:00-05:00 User: 2 3 17:00-23:00 * 6.5.2 Illustration of menu Menu Description Heating Set Electric heating Manu Mode Manual control mode Auto Mode Automatic control mode * electric heating function (Factory setting: ) Temp Set Set the temperature for start or Stop electric heating device Time Set Set the time period for start or Stop electric heating device ON Temp Set the temperature for start electric heating device Range: 0 ~50 (Factory setting: 40 ) Temp Set the temperature for Stop electric heating device Range: 45 ~90 (Factory setting: 60 ) 24H ON All day on electric heating function 24H All day off electric heating function User User defined the time period for start or Stop electric heating device 1 04:00-05:00 2 3 17:00-23:00 Three time period of user defined. The time period will be, If they are the same. (e.g. 08:00 08:00 ) When the Manu Mode is chosen, will be shown in the normal screen. And when the electric heating device is operated, will flicker. When the Auto Mode is chosen, will be shown in the normal screen. And when the electric heating device is operated, will flicker. - 12 -

6.6 HT Set 6.6.1 Menu schematic diagram Tank Set Temp:75 HT Set ON Col Set ON Temp:115 Temp: 95 Sys Set Temp:140 6.6.2 Illustration of menu Menu Description HT Set High temperature protection ON ON high temperature protection function (Factory setting: ON) high temperature protection function Tank Set Tank protection Col Set Collector protection Sys Set System protection ON Temp (Col Set) Set the temperature for on collector protection Range: 100 ~130 (Factory setting: 115 ) Temp (Col Set) Query the temperature for off collector protection Value : 95 (Factory setting: 95 ) Temp (Tank Set) Set the temperature for off tank protection Range: 50 ~90 (Factory setting: 75 ) Temp (Sys Set) Query the temperature for off system protection Value : 140 (Factory setting: 140 ) When the High temperature protection function is ON, will be shown in the normal screen. And when the tank protection is operated, will be shown in the normal screen. And when the collector protection is operated, will be shown in the normal screen. And when the system protection is operated, will be shown in the normal screen. - 13 -

6.7 AF Set 6.7.1 Menu schematic diagram ON ON Set:10 Set:15 AF Set 6.7.2 Illustration of menu Menu Description AF Set Anti-freeze protection ON On anti-freeze function Off anti-freeze function (Factory setting: ) ON Set Set the temperature for open solar pump (P1) Range: -10 ~30 (Factory setting: 10 ) Set Set the temperature for stop solar pump (P1) Range: -10 ~30 (Factory setting: 15 ) When the Anti-freeze function is ON, will be shown in the normal screen. And when the solar pump is operated, will flicker. - 14 -

6.8 Ste Set 6.8.1 Menu schematic diagram ON ON Time:23:00 Temp:70 Ste Set 6.8.2 Illustration of menu Menu Description Ste Set Sterilization protection ON On sterilization protection function Off sterilization protection function (Factory setting: ) ON Time Temp Query the time for start electric heater Value : 23:00 04:00 (Factory setting: 23:00 04:00) Query the temperature for stop electric heater Value : 70 (Factory setting: 70 ) When the Sterilization protection function is ON, will be shown in the normal screen. And when the electric heating device is operated, will flicker. In the case of ON electric heating and ON sterilization protection function, when the water temperature in the tank is below 70 for 7 days, the electric heating device will be operated at 23:00 of the 7 th day, heating the water to 70, at which time the electric heating device will switch off. If the water temperature in the tank is still below 70 at 4:00 of the 8 th day, the electric heating device will switch off. If the tank protection temperature is set below 70, the electric heating device will only heat the water to the tank protection temperature, then switch off. - 15 -

6.9 Function icon Icon Illustration Sensor failure Temperature difference circulation Temp Mode of hot water pipe circulation Time Mode of hot water pipe circulation Manu Mode of electric heating Auto Mode of electric heating High temperature protection Tank Set of high temperature protection Col Set of high temperature protection Sys Set of high temperature protection Anti-freeze protection Sterilization protection - 16 -

7. Operation (An example) Before carrying out the operation,press any button to illuminate the screen. 7.1 How to choose auto mode of heating function : Main Menu 1 / 8 Temp Query System Set TD Set HWP Set OR Main Menu 5 / 8 Heating Set HT Set AF Set Ste Set OR Heating Set 1 / 3 Manu Mode Auto Mode Heating Set 2 / 3 Manu Mode Auto Mode OR Heating Set 2 / 3 Manu Mode Auto Mode - 17 -

7.2 How to set parameters of auto mode Heating Set 2 / 3 Manu Mode Auto Mode Auto Mode 1 / 2 Temp Set Time Set Auto Mode 2 / 2 Temp Set Time Set OR Time Set 3 / 3 24H ON 24H User User 1 / 3 1. 04:00 05:00 2. 3. 17:00 23:00 1 2 3 User 1 / 3. 03:00 05:00. 12:00 12:00. 17:00 23:00-18 -

7.3 How to change the important parameters System Set 4 / 5 Language/ 语 言 Time Set Brt Set Set Restore! YES Change? NO OR! YES Change? NO System Set 4 / 5 Language/ 语 言 Time Set Brt Set Set Restore - 19 -

7.4 Convenient usage of button : Heating Set 1 / 3 Manu Mode Auto Mode 7.5 Convenient usage of button : System Set 4 / 5 Language/ 语 言 Time Set Brt Set Set Restore - 20 -