INDUSTRIAL CABLE COUPLERS



Similar documents
25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

Directory chapter 04

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Generator DoCKInG StatIonS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

BIW Connector Systems. BIW Connector Systems. Electrical Feedthru Systems for Oil and Gas Wells. Electrical Feedthru Systems for Oil and Gas Wells

VOYAGER 570G. 744A Sprayer Control

Hook-Up and Lead Wire

Mini USB and USB 2.0-IP67 Connector System

General Purpose ph/orp Sensors

Cables. Accessories. For Force, Torque and Strain Sensors

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Series 8146/5-V37 and Series 8150/5-V37

A. Shop Drawing submittals shall include, but not be limited to, the following:

METHOD STATEMENT INSTALLATION OF INSULATING FLANGE KITS

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

EQUIPMENT RESTORATION AND REPAIR FROM WATER DAMAGE

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

EPIC CIRCON M23 Series Circular Signal Connectors

STANDARD MICRO-D CONNECTORS

picomax The Pluggable Connection System

D e s c r i p t i o n a n d De s i g n Fe a t u r e s

DRESSER TM PIPELINE SOLUTIONS

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

W1 Connector W1 Adapter W1 Termination

Scraper Passage Indicator. Electrical Indicator. Features

a Nexans company Catalogue 2014

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

400 Series Buccaneer BUCCANEER POWER. bulgin

COAXICON Contacts. RF Coax Connectors. Product Facts

Advantium 2 Plus Alarm

Thermal Adhesives Ther-O-Bond 1500

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Explosion proof enclosures

PowlVac Vacuum Integrity Tester

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

TAMPERS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

IEC Connectors. Introduction

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Ford Pipe Repair Products The Ford Meter Box Company, Inc.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

SMA Connectors. RF Coax Connectors. Product Facts

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

with installation dynafact boost GAUGE this manual is for use with systems

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Introducing an All New Line of Cleaning Chemicals

Series Hose Reels

CHEMICAL CLEANING UNIT Product number:

Rugged & Reliable Power Connections

UNITOR VACUUM cleaners

SMA Interface Mating Dimensions (Per MIL-STD-348)

A&C Solutions: please contact us.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Submersion/Insertion Toroidal Sensor

Toroidal Conductivity Sensor

DRAIN CLEANING MACHINES

Waterproof Connectors for Outdoor Use

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Co-location Interconnect Power Panel (CIPP) Installation Guide

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

SOURIAU s discrete wire sealing

DYNA RIDER FOOTBOARD KIT

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Operating Instructions

Plus ESG50GL Battery-powered, High-speed Cable Cutter

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Installation Instructions for EHD, EDB, EDS, ED, EDH, EDC, FDB, FD, HFD, FDC, HFDDC Circuit Breakers and Molded Case Switches

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

AKRAPOVIC SLIP-ON EXHAUST SYSTEM for the HONDA CB1000R

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

81000 Series Aluminum Gate Valve Installation and Repair Manual

ANTENNA PARTS CATALOG

Power Supply Cables and Connectors

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

DOUBLE CONTAINMENT DESIGN & INSTALLATION GUIDE

V47 Series Temperature Actuated Modulating Water Valves

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Transcription:

ADALET PLM INDUSTRIAL CABLE COUPLERS www.adalet.com/plm

Portable Cable Systems Couplers / Plugs-Receptacles Cable Couplers Identification & Application Couplers are utilized in underground, strip, and pit operations on every continent in the world. Adalet PLM Cable Couplers provide safe, convenient means for connecting portable cable rated up to 15,000 volt and up to 500 Amperes, copper or aluminum conductor to mining equipment, electric shovels, drag lines, loaders, barges, tunneling machines, portable substations, portable junction boxes, or for joining lengths of high voltage cables. PLM Cable Coupler Q P M L Q T B Blank MATING THREAD FORM Quik-Thread Double Start ACME Thread Quik-Turn Ramp Style Quik-Flip Bolt Style Standard 8-Pitch HOUSING S Socket P Plug CONTACTS M Male F Female MOUNTING G Gear/Equipment Mount L Line/Cable Mount APPLICATIONS Extending Portable Cables Mine Power Cables Electric Shovels, Drills, drag lines Tunneling Machines Transformer Connections Barge, Ship-Dock Applications Turbine Generators Motor Disconnect 600V-15kV to 500 Amp FEATURES Corrosion-resistant aluminum Rigid, non-breakable insulators 500 Amp contacts Portable cable mounting Switchgear or equipment mounting Standard cover, stress control kit instructions included 4801 West 150th Street Cleveland, Ohio 44135 216.267.9000 www.adalet.com/plm

To order, PROVIDE: 1. Conductor sizes of phase, ground wires, and ground check wire 2. Overall cable diameter. Contact Adalet sales representative or email info@adalet.com to place order. Selection Guide 415 A B Voltage class & End bell size ground check A One contact included AA Two contacts AAA Three contacts AAAA Four contacts 415 Accommodates cable diameter ranging from 1.50 to 3.50 515 Accommodates cable diameter ranging from 3.51 to 4.50 Added features B BB C E L N P R TF Z Interlock contacts in cover for plug Interlock contacts in cover for socket Kirklock sockets only Electrolytic copper contacts-female Insulation in plug mount Non-interchangeable amperage or voltage index Padlock provision socket Insulation in socket cover Teflon insulator Beryllium contacts BENEFITS Superior electrical and physical protection Fewer mating problems Quicker installation Quick connect - disconnect Versatile application COMPLIANCE Pennsylvania Bureau of Deep Mine Safety

415 / 515 Series Cable Couplers Standard EPDM Insulators 15kv, 500 Amp 415/515 Series Cable Couplers are suitable for use up to 15kV. Each coupler includes silver-plated copper contacts rated up to 500 amperes. PLM Couplers feature a durable, corrosion-resistant aluminum shell. Rigid, non-breakable, EPDM insulator tubes are supplied standard. 415/515 Series Couplers are available in line-mount (cable-mount) or gear-mount (equipment-mount) configurations. Select from four different connection options to provide the best solution for your application. Each coupler we ship includes a stress control kit and detailed installation instructions. Several options are available to customize each coupler to your specific requirements. FEATURES Corrosion-resistant aluminum Rigid, non-breakable EPDM insulators 500 amp contacts Portable cable mounting Switchgear or equipment mounting Standard cover, stress control kit instructions included BENEFITS Superior electrical and physical protection Fewer mating problems Quicker installation Quick connect-disconnect Versatile application Compound is not included and is not required up to 7,500 volts. Above 7,500 volts and when compound is required, use COLDPOUR Compound. Do not use asphalt compound with EPDM style couplers. Compound mandatory for 15kv. Standard Threads Acme Quik-Thread Quik-Turn Quik-Flip Description Ship Weight (lbs) SFG 415 A PMG 415 A QSFG 415 A QPMG 415 A TSFG 415 A TPMG 415 A BSFG 415 A BPMG 415 A Equipment-mounted couplers socket, female contacts plug, male contacts 34 SFL 415 A PML 415 A QSFL 415 A QPML 415 A TSGL 415 A TPML 415 A BSFL 415 A BPML 415 A Line-mounted couplers 1.50-3.50 O.D. cables socket, female contacts plug, male contacts 51 SFL 515 A PML 515 A QSFL 515 A QPML 515 A TSFL 415 A TPML 415 A BSFL 515 A BPML 515 A 3.50-4.50 O.D. cables socket, female contacts plug, male contacts 53 Options Available at Additional Cost 3 Suffix -A -AA -B -BB -C -E -L -N -P -R -Z -TF Ground check circuit contact (1) included Two ground check circuit contacts Cover interlock for plug Cover interlock for socket Kirk interlock (key-type)-sockets only Electrolytic copper contacts-female Cover/insulator assembly for plug Non-interchangeable amperage or voltage index Padlock provision-socket Cover / insulator assembly for socket Beryllium contacts-male Teflon Insulator QPLM415A 4801 West 150th Street Cleveland, Ohio 44135 216.267.9000 www.adalet.com/plm

415 / 515 Series Cable Couplers Teflon Insulators 15kv, 500 Amp Teflon tubes combine a non-tracking, easy-to-clean hydrophobic material with an internal o-ring seal between tubes. 415/515 Series Couplers are available in line-mount (cable-mount) or gear-mount (equipmentmount) configurations. Select from four different connection options to provide the best solution for your application. Each coupler we ship includes a stress control kit and detailed installation instructions. Several options are available to customize each coupler to your specific requirements. combining a non-tracking, easy-to-clean hydrophobic material with an internal o-ring seal between tubes. FEATURES Corrosion-resistant aluminum Rigid, non-breakable Teflon insulators 500 amp contacts Portable cable mounting Switchgear or equipment mounting Standard cover, stress control kit, instructions included Solid polyester fiberglass flange Teflon tubes O-ring sealed to flange Nylon lock nuts for positive seal BENEFITS Superior electrical and physical protection Fewer mating problems Quicker Installation Quick connect-disconnect Versatile application Teflon is a registered trademark of EJ. DuPont de Nemours and Company. Standard Threads Acme Quik-Thread Quik-Turn Quik-Flip Description Ship Weight (lbs) SFG 415 ATF PMG 415 ATF QSFG 415 ATF QPMG 415 ATF TSFG 415 ATF TPMG 415 ATF BSFG 415 ATF BPMG 415 ATF Equipment-mounted couplers socket, female contacts plug, male contacts 34 SFL 415 ATF PML 415 ATF QSFL 415 ATF QPML 415 ATF TSGL 415 ATF TPML 415 ATF BSFL 415 ATF BPML 415 ATF Line-mounted couplers 1.50-3.50 O.D. cables socket, female contacts plug, male contacts 51 SFL 515 ATF PML 515 ATF QSFL 515 ATF QPML 515 ATF TSFL 415 ATF TPML 415 ATF BSFL 515 ATF BPML 515 ATF 3.50-4.50 O.D. cables socket, female contacts plug, male contacts 53 4 Options Available at Additional Cost Suffix -A -AA -B -BB -C -E -L -N -P -R -Z Ground check circuit contact (1) included Two ground check circuit contacts Cover interlock for plug Cover interlock for socket Kirk interlock (key-type)-sockets only Electrolytic copper contacts-female Cover/insulator assembly for plug Non-interchangeable amperage or voltage index Padlock provision-socket Cover / insulator assembly for socket Beryllium contacts-male 4

415 / 515 Series Cable Couplers Standard EPDM Insulators 15kv, 500 Amp Electrical Characteristics Maximum voltage phase-to-ground 1 minute dry withstand AC 6 hour dry withstand DC 15 minute dry withstand DC Corona extinction level Basic impulse level No Compound With Compound 5.5 KV rms 8.7 KV rms 35.0 KV rms 45.0 KV rms 25.0 KV rms 35.0 KV rms 65.0 KV rms 75.0 KV rms 7.5 KV rms 11.0 KV rms 75.0 KV crest 95.0 KV crest All tests per IEEE Standard 48-1990 415 / 515 Series Cable Couplers Teflon Insulators 15kv, 500 Amp Electrical Characteristics Maximum voltage phase-to-ground 1 minute dry withstand AC 6 hour dry withstand DC 15 minute dry withstand DC Corona extinction level Basic impulse level No Compound With Compound 5.5 KV rms 8.7 KV rms 35.0 KV rms 45.0 KV rms 25.0 KV rms 35.0 KV rms 65.0 KV rms 75.0 KV rms 7.5 KV rms 11.0 KV rms 75.0 KV crest 95.0 KV crest All tests per IEEE Standard 48-1990 PLM Contact Pins 5 PLM s standard couplers include silver-plated, copper contact pins that provide excellent electrical connections. Phase and ground contacts are modified to your specific cable requirements. Simply specify the phase and ground conductor diameter and PLM will pre-drill the contact pins to meet your specifications and reduce installation time. 4801 West 150th Street Cleveland, Ohio 44135 216.267.9000 www.adalet.com/plm

Conversion Kits Any cable coupler, line mount or gear mount, may be converted to Quik-Thread, Quik-Turn, or Quik-Flip style. These style couplers will not mate with standard 8 pitch thread couplers; therefore, it is necessary to change the socket body, lock ring, and covers. Select the correct conversion plug or socket kit from the table below. Kits include only the thread parts which must be changed, plus new screw, and gaskets. Conversion kits should be applied to all couplers on any single cable system. Quik-Thread coupler rings are color-coded green to provide positive identification. Quik-Turn coupler rings are color-coded orange. All tests per IEEE Standard 48-1990 Catalog Number ACME Thread Parts Furnished Description QKP-8 TKP-8 BKP-8 Plug cover and lock ring Replacement for plug-style couplers. Includes plain cover (without drilling for pilot or ground contacts). QKP-M/F-8 TKP-M/F-8 QKP-M/F-15 TKP-M/F-15 Plug cover (drilled for pilot and ground contacts) and lock ring Plug cover (drilled for pilot and ground contacts and for cover insulator assembly) and lock ring Replacement for plug-style couplers. Includes cover drilled for ground contacts (male or female). Customer to use existing contacts. Replacement for plug-style couplers. Includes cover drilled for ground and pilot contacts (male or female) and for cover insulator assembly. Customer to use existing contacts and cover insulator assembly. 6 QKS-8 TKS-8 BKS-8 Socket cover and body Replacement for socket-style couplers. Includes plain cover (without drilling for pilot or ground contacts). QKP-M/F-8 TKP-M/F-8 Socket cover ring and socket body Replacement for socket-style couplers. Includes cover ring to be used with existing cover. Customer to use existing contacts. QKP-M/F-15 TKP-M/F-15 Socket cover ring and socket body Replacement for socket-style couplers. Includes cover ring to be used with existing cover and cover insulator assembly. Customer to use existing contacts.

Connection Options Quik-Flip Bolted Coupler Connection PLM s Quik-Flip connection option is ideal for harsh environments where excessive dirt and other contaminants can seize threads and cause coupler damage. The innovative flip-bolt design utilizes stainless steel bolts that provide a one-second time delay between ground check and phase contact disengagement. Quik-Flip EPDM Insulators Quik-Flip Teflon Insulators BSFG 415A BPMG 415A BSFL 415A BSFG 415ATF BPMG 415ATF BSFL 415ATF BPML 415A BPML 415ATF BSFL 515A BSFL 515ATF BPML 515A BPML 515ATF Other options available on 415/515 series couplers 8-pitch Thread (standard) A simple, cost effective solution for use in any application Quik-Turn Ramp Style Quarter-Turn Color-coded orange (use prefix T when ordering) Ideal for use in applications where frequent connection and disconnection is required. 7 Quik-Thread Double-Start ACME Thread Color-coded green (use prefix Q when ordering) Our most popular connection style, wide threads and Teflon coating make them easy to clean and maintain. 4801 West 150th Street Cleveland, Ohio 44135 216.267.9000 www.adalet.com/plm

Accessories Coupling and Contact Wrenches Standard Threads WR Description Ship Weight (lbs) Contact wrench for 415, 515 series 1 WR C-1008 C-1008-S Coupling wrench (aluminum) for 415, 515 series Coupling wrench (steel) for 415, 515 series 1 3 C-1008 COLDPOUR Compound Compound filling can prevent condensation and provide added protection in wet locations. Asphaltic compounds cannot be used with EPDM insulations. For those customers who wish to use compound, Adalet offers a COLDPOUR compound which does not require heating for installation or removal. Suitable for all couplers. No shrinkage or waste. Approximately 2-hour gel time. Shelf life 6 mos. Should be installed at normal room temperature and allowed to cure for 24 hours CP-40 CP-50 Description 1 5/8 gal. 2-part mix for one LINE mount or two GEAR mount couplers, series 415 coupler 1 7/8 gal. 2-part mix for one LINE mount, series 515 coupler Ship Weight (lbs) 13 14 8

Accessories Spare Parts PLM couplers and accessories are utilized in some of the world s most extreme environments. PLM offers a full line of spare parts for use in maintaining, rebuilding, or repairing used couplers. All individual coupler parts are available for purchase. Most are in stock and available for immediate shipment. Contact PLM or your local PLM distributor for price and availability information. PLM A KIT Coupler Contact Insulation Cleaning Kit Dirt contamination can cause electrical failures. The mating contact insulators can be efficiently cleaned with the PCK100 Cleaning Kit. The solvent used in our PCK-100 cleaning kit is an exceptional solvent degreaser formulated without chlorinated solvents or other hazardous ingredients. With its high flash point, the solvent provides an unprecedented degree of user safety. It is strong enough to remove grease, fuel oil, carbon and organic resins yet safe on most plastic and rubber surfaces. The PLM solvent degreaser: Contains no water Fully evaporative, leaves no residue No hazardous ingredients as defined by the EPA Not a flammable liquid (TCC flash point above 145 F) No surface leakage of current in immediate residue tests High dielectric strength (ASTM D-877 test procedures to 46,000 volts) 9 Description Ship Weight (lbs) PCK-100 Cleaning Kit 1.5 Kit consists of 12-oz. spray bottle of non-flammable electrical parts cleaner, bristle brush, two white wiping cloths and polyethylene glove. 4801 West 150th Street Cleveland, Ohio 44135 216.267.9000 www.adalet.com/plm

PLM was founded in 1951 by Francis Calvert, a cable engineer previously employed by General Electric. G. E. developed a line of interlocked armor cable, but there were no fittings available for terminations. Calvert manufactured the first fittings in his basement. Later that year, he sold the business to John Pescke, Quigg Lohr, and Carroll Miller, whose initials (PLM) formed the company name. Starting with fittings for armored cables, PLM soon developed splices, terminations, and other accessories for joining cables. In 1957, PLM developed the first coupler designed with a ground check interrupting circuit for safe disconnect, and the first coupler capable of handling 500 amperes at 7500 volts. In 1963, PLM and Adalet (high quality manufacturer of hazardous location enclosures and accessories) were acquired by the Scott Fetzer Company. The operations of Adalet and PLM merged in 1977.

ADALET HEADQUARTERS 4801 West 150th Street Cleveland, Ohio 44135 TEL 216.267.9000 FAX 216.267.1681 ADALET HOUSTON 4300 Windfern Road Suite 200 Houston, Texas 77041 TEL 713.996.7331 FAX 713.996.7368 NCAT111 info@adalet.com www.adalet.com/plm 2012 ADALET