NUM INFORMATION US N 111 1/9



Similar documents
OPERATOR INTERFACE PRODUCTS APPLICATION NOTE. Xycom 4800/2000 OIL (Operator Interface Language)- Series Terminals: Backup and Restore with ProComm

Maintaining the Content Server

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Memex Automation Inc. Fanuc CNC Backup Instruction Manual

PPM Users Manual Signature Software

Guide to Installing BBL Crystal MIND on Windows 7

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

#65 4GHGTGPEG")WKFG #FXCPEGF"6GTOKPCN"5QHVYCTG 8GTUKQP"502 HQT"%QPVTQNNGT/#% Catalog # Rev.02

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

PRN_LOAD :22

POS Integration. Prepared by: Binh Nguyen

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

DUKANE Intelligent Assembly Solutions

Centurion C4 Transfer Guide using C4 File Transfer Utility

V2.0 Attendance System Hardware Suite Guide Instructions Manual

Polycom CMA System Upgrade Guide

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

Communications Instructions for DOOSAN, FANUC Controls

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

LTM-1338B. Plus Communications Manual

Access Control Software Manual

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

TP- 051 GPS RECEIVER

3.1 Connecting to a Router and Basic Configuration

Korosi Monitoring System (KMS) Software Manual

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

Voice Over Internet Protocol (VoIP) Configuration

Read Me UNISTREAM AUTOMATION IDE

Keep it Simple Timing

64-Bit Compatibility with Micromeritics Applications

Remote PC Guide Series - Volume 2a

General Precautions The user must operate each product according to the performance specifications described in the operation manuals.

Fanuc O4P-C Parameter and Macro Program Back-up and Restore Procedure

Guide to SATA Hard Disks Installation and RAID Configuration

Single channel data transceiver module WIZ2-434

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Basic Router and Switch Instructions (Cisco Devices)

MTA Course: Windows Operating System Fundamentals Topic: Understand backup and recovery methods File name: 10753_WindowsOS_SA_6.

Memory Upgrade Fanuc 16 & 18 A/B/C Series CNCs

UPS Monitoring and Management Software

INF-USB2 and SI-USB Quick Start Guide

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

L Firmware And FPGA Configuration Upgrade

A MANUAL ON SIEMENS SOFTWARE AND CABLE CONFIGURATIONS THIS SOFTWARE COMES WITH ALL TOOLBOX VERSIONS OF 802D

Moxa Device Manager 2.0 User s Guide

Config software for D2 systems USER S MANUAL

Appendix A. This Appendix includes the following supplemental material:

To use your Brother machine in an ad hoc network, complete the steps listed below:

Introduction. Setting Up the Scanner. Performing Verification Sequence

Installing Remote Desktop Connection

airbackup installation and AdmiCash backup

History of Revisions. Ordering Information

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

Guide to SATA Hard Disks Installation and RAID Configuration

ATS Advanced Terminal Software Version 1.9 Reference Guide for Controller-A

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

QT-6000 FTP CLIENT SETUP

Server Manual. For Administrators of Cameleon Version 4

SCADAPack E ISaGRAF 3 User Manual

Guide to SATA Hard Disks Installation and RAID Configuration

1. Requirements for Network Installation on 840D

Important Notes for WinConnect Server VS Software Installation:

Instructions for transferring the SINUMERIK HMI to an external screen

PC Software for VAV compact and modular controllers

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

WinPFT File Transfer Utility (Catalog No ND7)

2013 Brother International Corporation (Canada) Ltd. 1, rue Hôtel de Ville, Dollarddes-Ormeaux,

Topaz Installation Sheet

Quick Installation and Setup for WinPower Software

AMT Implementation on a UTC RETAIL 3170 POS

Quick Installation and Setup for WinPower Software

4 Backing Up and Restoring System Software

Modbus Communications for PanelView Terminals

ProVisual AC-8000P. User Manual. For the optimal use and maintenance of the product, Please read the manual carefully before using it.

File Management Utility. T u t o r i a l

Global Monitoring + Support

ISHIDA BC Scale to Scale Communications

How-To Set Custom Scale Format for FedEx Ship Manager

Guide to SATA Hard Disks Installation and RAID Configuration

U90Ladder / VisiLogic /UniLogic and software utilities system requirements. Contents

Copley Camming User Guide

APNT#1168 Modbus - Establishing Communications Hints

User Manual. Thermo Scientific Orion

Lab Configuring Access Policies and DMZ Settings

VRX Company Inc. Application Note: DacEasy Point of Sale setup for Pole Display

educ Office Remove & create new Outlook profile

Cloning Utility for Rockwell Automation Industrial Computers

Upgrading LytecMD from to 9.4 on Windows Server Best Practices. Revision Date: 7/29/2010 PLEASE READ:

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

ScanShell.Net Install Guide

Intel Rapid Storage Technology

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Colorfly Tablet Upgrade Guide

Analysis Software AFF 20-60mn

PROGRAMMING SOFTWARE FOR ASYNCHRONOUS SERIAL ENCODERS AMS / ATS / AMM / ATM

WindO/I-NV2 Utility Pass-Through Tool

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Transcription:

US N 111 1/9 Procedure: 10xx Series CNC Backup/Restore Procedures using NUMCOM Scope: The NUM 10xx Series CNC system has essential application specific files stored in various locations within the system. (See US117 10xx Series System Memory Map.) It is important to periodically backup this system memory to prepare for data loss due to system failures. The purpose of this document is to provide the user with a detailed step-by-step procedure for setting up the RS-232 communication link from the PC to the CNC and downloading/uploading the individual files necessary for a backup/restoration of the CNC. ** NOTE** This software package requires user interface on both the CNC and the PC. Datum offsets (shifts), tool-wear offsets, and E8xxxx parameters are not supported by NUMCOM. NUMBackup is the only package to support backup of these files. 1. RS-232 cable diagrams: (See US112 Communication Cables for Use with NUM CNC s and NUMDrive products) 2. Set up communication link on CNC. a. Press F11 (Utility). b. Type 0 and <enter> for Access to utility programs. c. Type 7 and <enter> for PLC Ladder Programming (UTILITY 7) d. Type F and <enter> for File management. e. If top line says I- port is private to PLCTOOL, Type I and <enter> so line says V -Port is now set public. f. Press F11 to exit. g. Press CTRL-S to exit this screen.

US N 111 2/9 h. Press F11 to get to CN Utility Menu. i. Type 1 and <enter> for Serial Line Parameters (CN UTILITY 1). j. See Section 8.3 in the Operator Manual (938822 or 938821) for details on setting up protocol. Figure 1 - Serial Line Parameters Data k. Should be set to: Line number (based on port cable is hooked up to, see appendix Figure 2, for line numbers) Standard RS232 Input speed (based on communication rate you want to use usually 19200 or 9600.) Output speed (based on communication rate you want to use usually 19200 or 9600.) # start bits 1 # data bits 8 # stop bits 1 Parity None Protocol None Flow control RTS/CTS Logical name (whatever you want to put there) l. The CNC is now set up for communications.

US N 111 3/9 3. Set up communications on PC a. Run NUMCOM. *NOTE* If operating system is Windows 95/98 you may need to shut down into DOS for this to communicate properly. b. Press <enter> for Configuration c. Ensure proper active serial port on PC is selected. If it is, press <enter>. d. Select proper receive baudrate based on previously set output speed on CNC. Press <enter>. e. Select proper send baudrate based on previously set input speed on CNC. Press <enter>. f. Ensure handshake signal says yes. Press <enter>. g. Press <enter> until you reach the main menu. h. PC is now set up for communications. 4. Backup Procedures Following steps (4a.) through (4d.), will create a full NUMCOM system backup. As you create your backup files, it is also recommended that a readme.txt file be created for future reference to indicate your file names, type of data contained in the file, as well as method used to create the backup file. Steps (4e.) through (4f.) although not required, creates individual backups for data created in the binary archive file of section (4a.). a. Targeted Memory Area: (Machine Parameters, Software options, Axis calibrations, Macros Zone 1,2, &3) Method: Machine Backup Utility. File created : 1- Binary file. 1). On PC, press 3 and <enter> for Receive Binary File 2). On CNC a). Press F11 b). Press 3 and <enter> for Machine backup (CN UTILITY 3) c). Press 0 and <enter> for Backup d). Press Y and <enter> for question Storage Unit Ready? (Y/N) e). CNC will say RUNNING. f). When backup is completed, CNC will say UNLOAD COMPLETED. 3). After file is downloaded give it a name. Initially it will say RECORD.BIN. 4). After backing up software, it is advisable to do a compare. a). From Machine Backup menu on CNC, press 2 and <enter>. b). Press Y and <enter> for question Storage Unit Ready? (Y/N) c). CNC will say RUNNING d). On PC, press ESC key to return to main menu e). Press 5 and <enter> for Send Binary File

US N 111 4/9 e). Press arrow keys till file to be downloaded is highlighted and press <enter>. f). CNC will say VERIFY COMPLETED if OK or VERIFY ERROR if not OK. 5). For more information, see Operator Manual (938822 or 938821) Section (8.5) b. Targeted Memory Area: (Tool Offset table) Method: Unload Mode File created : 1- ASCII file. 1). On PC, press 2 and <enter> for Receive ASCII File. 2). On CNC: a). Select Unload Mode (Press Mode Key twice and Unload (F5) or for compact panel: press context key, press Mode softkey F2, press next key, which is F11, and Unload (F5)) b). Type 1 and <enter> for Tool Offset. c). Press <enter> one more time and watch for M02 at top of screen to change to INCYC. 3). When file transfer is completed, INCYC indicator will return to M02. 4). After file is downloaded give it a name. Initially it will say RECORD.LIS. 5). For more information, see Operator Manual (938822 or 938821) Section (5.6.2) c. Targeted Memory Area: (All part programs in user zone, [ZONE 0]) Method: Unload Mode Other Part Programs - File created : 1- ASCII file. 1). On PC, press 2 and <enter> for Receive ASCII File 2). On CNC: a). Select Unload Mode (Press Mode Key twice and Unload (F5) or for compact panel: press context key, press Mode softkey F2, press next key, which is F11, and Unload (F5)) b). Type 2 and <enter> for Other Program. c). Press <enter> one more time and watch for M02 at top of screen to change to INCYC. d). At prompt, type %% (for all programs) and press <enter>. 3). When file transfer is completed, INCYC indicator will return to M02. 4). After file is downloaded it may already be named, otherwise it will ask for the file to be named. Initially it will say RECORD.LIS. 5). For more information, see Operator Manual (938822 or 938821) Section (5.6.1.2).

US N 111 5/9 d. Targeted Memory Area: (All PLC Logic) Method: Utility 7 (or Utility 6) - PLC archive - File created : 1- Binary file. 1). On PC, press 3 and <enter> for Receive Binary File 2). On CNC: c). Type 7 and <enter> for PLC Ladder Programming (UTILITY 7) d). Type S and <enter> for Software Backup e). Type U and <enter> for Unload the software. f). Display will say UNLOADING IN PROGRESS with little curser twirling in lower R/H corner of screen. 3). After file is downloaded give it a name. Initially it will say RECORD.BIN. 4). After backing up software, it is advisable to verify the software. a). On CNC, type V and <enter> for verify the unload. CNC will say Waiting and then TESTING IN PROGRESS. b). On PC, press ESC key to return to main menu. c). Type 5 and <enter> for Send Binary File d). Press arrow keys till file to be downloaded is highlighted and press <enter>. e). When completed, CNC will say Test OK. f). On CNC press F11 to exit. g). Press CTRL-S or X-off softkey to exit to utility menu. 5). For more information, see PLC LADDER Programming Manual Section (18.2.6) e. Targeted Memory Area: (Machine parameter data) Method: Utility 5 Machine Parameter - File created : 1- ASCII file. 1). On PC, press 2 and <enter> for Receive ASCII File 2). On CNC c). Type 5 and <enter> for Machine setup data (UTILITY 5) d). A warning message may appear that says Warning! Machine Control Will Be Stopped When Changing Parameters OK? (Y/N) just type Y and <enter>. e). Type 3 and <enter> UNLOAD f). A question will be displayed: Ready?. Type Y and <enter> g). The affaire number will be displayed (ex. %11122200), press <enter>. h). After file is downloaded, file will name itself affaire.lis, ex. 111222.lis.

US N 111 6/9 i). Press CTRL-S or X-off softkey to exit to utility menu. 3). For more information, see Parameter Manual (section 13.2.4) f. Targeted Memory Area: (Protected Part Programs ZONE 1, ZONE 2, ZONE 3) Method: Utility 3 Protected Part Program Zones- Files created : 3- Binary files. 1). On PC, type 3 and <enter> for Receive Binary File. 2). On CNC c). Type 3 and <enter> for resident macros (UTILITY 3) d). Type 5 and <enter> Unload/Verify e). Select zone to be unloaded, 1,2, or 3. Type number and <enter>. f). Type % and <enter> to download all programs g). A question will be displayed: Unload (Y/N). Type Y and <enter> 3). After file is downloaded give it a name. Initially it will say RECORD.BIN. 4). A question will be displayed: Verify (Y/N). Type Y and <enter>. 5). On PC, press ESC key to return to main menu. 6). Type 5 and <enter> for Send Binary File 7). Press arrow keys till file to be downloaded is highlighted and press <enter>. 8). CNC will display Verification in process and when completed will display BACKUP OK. 9). For more information, see Operator Manual (938822 or 938821) Section (8.7.7) 5. Restore Procedure Follow steps (5a.) through (5d.), to recover the full NUMCOM system backup, created previously in steps (4a.) through (4d.). If partial recovery is desired skip to the specific section. Steps (5e.) through (5f.) although not required, allow individual recovery of data created in steps (4e.) through (4f.). a. Targeted Memory Area: (Machine Parameters, Software options, Axis calibrations, Macros Zone 1,2, &3) Method: Machine Backup Utility 1). On CNC a). Press F11 b). Press 3 and <enter> for Machine backup (CN UTILITY 3) c). Press 1 and <enter> for Restore. d). Press Y and <enter> for question Storage Unit Ready? (Y/N) e). CNC will say RUNNING.

US N 111 7/9 f). When completed CNC will say LOAD COMPLETED. 2). On PC, press 3 and <enter> for Send Binary File 4). For more information, see Operator Manual (938822 or 938821) Section (8.5) b. Targeted Memory Area: Tool Data Method: Load Mode 1). On CNC: a). Select Load Mode (Press Mode Key twice and Load (F4) or for compact panel: press context key, press Mode softkey F2, press next key, which is F11, and Load (F4)) b). Type 1 and <enter> for Tool Offset. c). Press <enter> one more time and watch for M02 at top of screen to change to INCYC. 2). On PC, type 4 and <enter> for Send ASCII File 4). When file transfer is completed, INCYC indicator will return to M02. 5). For more information, see Operator Manual (938822 or 938821) Section (5.6.2) c. Targeted Memory Area: Part Programs (Memory ZONE 0) Method: Load Mode 1). On CNC: a). Select Load Mode (Press Mode Key twice and Load (F4) or for compact panel: press context key, press Mode softkey F2, press next key, which is F11, and Load (F4)) b). Type 0 and <enter> for Programs. c). Press <enter> one more time and watch for M02 at top of screen to change to INCYC. 2). On PC, type 4 and <enter> for Send ASCII File 4). When file transfer is completed, INCYC indicator will return to M02. 5). For more information, see Operator Manual (938822 or 938821) Section (5.6.1.2). d. Targeted Memory Area: PLC Logic Method: Utility 7 (or Utility 6) 1). On CNC:

US N 111 8/9 c). Type 7 and <enter> for PLC Ladder Programming (UTILITY 7) d). Type S and <enter> for Software Backup e). Type L and <enter> for Load the software. f). Display will say LOADING IN PROGRESS with little curser twirling in lower R/H corner of screen. g). When unload is completed, CNC will display PROGRAM LOADING OK. 2). On PC, type 5 and <enter> for Send Binary File. 4). For more information, see PLC LADDER Programming Manual Section (18.2.6) e. Targeted Memory Area: Machine Parameters Method: Utility 5 - Machine Setup Data 1). On CNC c). Type 5 and <enter> for Machine setup data (UTILITY 5) d). A warning message may appear that says Warning! Machine Control Will Be Stopped When Changing Parameters OK? (Y/N) just type Y and <enter>. e). Type 2 and <enter> for LOAD f). A question will be displayed: Ready?. Type Y and <enter> 2). On PC, type 4 and <enter> for Send ASCII File. 3). When file load is complete CNC screen will revert to Utility 5 menu. 4). For more information, see Parameter Manual (13.2.4) f. Targeted Memory Area: ZONE 1, 2, & 3 Method: Utility 3 1). On CNC c). Type 3 and <enter> for resident macros (UTILITY 3) d). Type 4 and <enter> Unload/Verify e). A question will be displayed: Load WARNING! SHUT DOWN THE POWER READY? (Y,N). Type Y and <enter> f). While loading CNC will display WRITING IN PROGRESS and when completed will display BACKUP LOADED. 2). On PC, type 5 and <enter> for Send Binary File. 4). For more information, see Operator Manual (938822 or 938821) Section (8.7.7)

US N 111 9/9 Appendix - Figure 2-10xx Series CNC, Line Numbers