300 MY HOME Energy management



Similar documents
F454. Web Server. User Manual 05/12-01 PC

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ZigBee Wireless Sensor Networks

15 Series - Electronic step relay and dimmer. Features SERIE

Anti-blackout system for grid connected solar installations (Solsafe concept)

Failure code manual. content

Electronic Control Devices The European Product Catalogue 2007

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Integrated solutions for comfort, energy efficiency, safety, video door entry, and control

EQUIPMENT SPECIFICATIONS

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

HERZ-Thermal Actuators

F453. TiF453. User guide 10/11-01 PC

Conventional Fire Detection and Extinguishant Control System Specification

Electronic Control Devices The European Product Catalogue 2007

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Thermostat with display

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

Counter for Energy. We make energy measurable and secure your future.

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Off-grid solar and backup power installations

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

A project to optimise quality and energy efficiency must include metering

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100

How To Build A Home Automation System On A Tv Remote Control

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

2 WIRE video door entry system

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

SYSTEM MONITORING Locally and remotely

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Inverter / Charger Installation General Operations and AC and DC Connections

CO2 Alarm. Operation. Application

3-phase, bidirectional energy meter

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

MicroFIT Connection Application Guidelines

D45. SySTEm. ThE high-performance

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

StruxureWareTM for Buildings

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

How to read this guide

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Achieving the impossible

Applications. diris_826_a_1_gb_cat

Maximum Demand Control

T7560A,B,C Digital Wall Module

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Reverse-feed applications for circuit breakers

386 MY HOME Video door entry and home video surveillance system

Heating and Hot Water Services Controls General Technical Specification

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

HCE80/HCC80/HCE80R/HCC80R

Documentation. M-Bus 130-mbx

CONTENTS MY HOME - VIDEO DOOR ENTRY AND HOME VIDEO SURVEILLANCE SYSTEM

ABB i-bus KNX Fan Coil Controller FC/S 1.1

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

MP-4000 Alarm List (Software version or later)

Thyristor-controlled power supplies and battery chargers

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Current Monitoring Kit QUICK START GUIDE

Data Sheet. Electro-mechanical counters Hengstler 800 series

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Quick Connect. quick - simple - efficient.

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Current Monitoring Kit

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Aerona Air Source Heat Pumps

Electronically Controlled Clutchless or Variable Drive Compressors

Photovoltaic Solar Energy Unit EESFB

Automatic start of a generator

MasterINTERFACE 39 Series - Relay interface modules

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Installation and operating instructions

Neuton Solar Power Diverter Quick Installation Guide

Remote Monitoring and REC 501 Control Unit Product Guide

E-STOP relays, safety gate monitors

38 Series - Relay interface modules A

Transcription:

300 MY HOME

COTETS. MY HOME oad control management General features. 302 General rules for installation. 308 Configuration 311 Wiring diagrams. 314 MY HOME 301

GEERA FEATURES The end of the black-out The My Home load control management system manages the maximum power used, by automatically disconnecting the least important appliances in case of overload The system: Manages up to 63 loads Displays on the display interfaces (e g ocal Display,, Webserver) the instantaneous and cumulative consumption on hourly, daily, and monthly basis, of the controlled phase In addition, thanks to the actuator with sensor, it is possible to measure the actual consumption of the controlled load It gives the possibility of disabling or re-enabling, using the display interfaces, the priorities configured based on the changed needs of the customer It gives the possibility of checking on the display interfaces the correct operation of the load using the measurement of the earth leakage current absorbed by the same Its devices (central unit and actuators) only require the space of one DI module This ensure optimisation of spaces inside the distribution boards By configuring the actuators of the load control system in automation mode, it is possible to use display interfaces to set the time delays for the activation of the loads at set times Dedicated icon on the screen of the touch screen 302 MY HOME

Power consumption screen (instantaneous / cumulative) Monthly power consumption graph Controlled loads screen Controlled load consumption display screen (with item F522) Diagnostic icon Energy consumption display icon oad control management icon MY HOME 303

GEERA FEATURES Operation Using the external toroid, the central unit measures the power used by the loads connected and compares it with the value preselected during the installation (using the configurators it is possible to select powers between 1 5 and 18 kw, with tolerances up to +/- 20%) An actuator is associated to each appliance being controlled The actuator receives the information from the central unit and disconnects the load from the network in case of overload The disconnection sequence of the actuators is defined during the installation using a simple configuration operation to be carried out on the devices themselves The central unit gives the possibility of managing up to 63 priority levels, Power meter Electric distribution board and a number of devices depending on the available supply current In the example shown, the oven, the microwave oven, and the washing machine represent the loads controlled using actuators, while the refrigerator, which operation is imperative that is not interrupted, is connected to his socket without actuator In case of overload, the first device that disconnects is the one considered the least important by the user, in the example the oven, which actuator has configurator no 1 The microwave is on the other hand the most important device, and the corresponding actuator Central unit for load management has configurator no 3 This load therefore only disconnects after the oven and the washing machine The user can reactivate the disconnected device at any time using the actuator pushbutton or the touch screen In this case, if the overload condition still exists, the central unit will enable the operation of the selected load, but will disconnect the subsequent loads starting from the least important, until the overload situation is resolved The operating status of the loads is notified both by the actuators and the touch screens By configuring the actuators of the load control management system also in automation mode, it is possible to use the touch screen to set the time delays for the activation of the loads at set times BUS on-controlled socket Flush mounted actuator Flush mounted actuator Flush mounted actuator on-controlled load OTE: inside the electric distribution board it is installed the central unit for load management Controlled load with priority 1 Controlled load with priority 2 Controlled load with priority 3 304 MY HOME

DISPAY FUCTIO The central unit for load management is capable of measuring the consumption of the controlled line using the toroid supplied The information is displayed on the touch screens, local displays, and on the web pages of the web server and the energy data logger DIAGOSTIC FUCTIO Thanks to the actuator with probe (Item F522), it is possible to display, in addition to consumptions, also the diagnostic, using the additional toroid (item ) of the controlled load The processing and accounting functions are: instantaneous consumption of the controlled line; hourly, daily, monthly and last 12 months cumulative consumptions Controlled loads diagnostic display screen Diagnostic icon oad OK oad near the earth leakage disconnection limit oad problems (e.g. device earth connection problems) MY HOME 305

GEERA FEATURES Device selection criteria CETRA UIT FOR OAD MAAGEMET F521 The device is capable of measuring the input power from the electric system and to control the status of the actuators of the load management system, to prevent the risk of tripping of the power meter The central unit manages up to 63 appliances or electric loads per each phase, measures currents and voltages, and processes these data to provide energy and power information The processing and accounting functions are: instantaneous consumption of the controlled line; cumulative hourly consumptions for the last 12 months, daily consumptions for the last 2 years, monthly consumptions for the last 12 years The central unit is suitable for installation inside distribution boards and switchboards and requires the space of 1 DI module Actuator 16A with current probe connection ACTUATOR 16 A WITH CURRET PROBE - ITEM F522 The device is an actuator with an integrated current probe for the measurement of controlled load consumptions (instantaneous consumption and 2 independently resettable energy totalizers), and is capable of performing both EERGY MAAGEMET and automation functions When configured in EERGY MAAGEMET mode, it gives the possibility of measuring the load input power, the power and the earth leakage current (through the connection of an external toroid, item ) The actuator is suitable for installation inside distribution boards and switchboards and requires the space of 1 DI module Central unit for load management Device status ED oad forcing pushbutton 16A actuator connection Configurator socket door connection Device status ED oad forcing pushbutton Device status ED oad forcing pushbutton Configurator socket door /BUS connection Configurator socket door /BUS connection /BUS connection 306 MY HOME

ACTUATOR 16A F523 The device is an actuator capable of performing both energy management and automation functions The actuator is suitable for installation inside distribution boards and switchboards and requires the space of 1 DI module oad status red ED Device status two-colour ED FUSH MOUTED ACTUATOR 16 A ITEMHC/HS/HD///T4672 Actuator conceived for installation in iving, ight, ight Tech and Axolute flush mounted supports, intended for the automation and/or EERGY MAAGEMET functions The device has: a local load forcing pushbutton; a red/green two-colour ED for the notification of the status of the actuator; central unit for load management red disabling signalling ED ocal pushbutton for load forcing/local control OAD COTRO PAE HD/HC/HS///T4673 The load control panel is a device that enables displaying the status of the loads controlled by the load control central unit, item F521, and force their operation independently from the central unit itself It is therefore possible to: Force the priority of the load during normal operation In this case the central unit cannot disable the load for 4 hours Re-enable a load disabled by the central unit, the duration of this operation lasts for 4 hours, unless the disabling key is pressed manually The functions that can be performed by the load control panel can also be performed by ocal Display (HD/HC/HS///T4685) With ocal Display it is however possible to manage up to 20 loads Flush mounted 16 A actuator Forced load key oad/programming status notification ED ocal Display oad control panel MY HOME 307

GEERA RUES FOR ISTAATIO oad control management and consumption display BUIDIG AYOUT The BUS system layout for the installation of oad Control Management System and the Display of Consumptions System offers the following advantages: Both for new systems, and installation in existing electric systems, the BUS line can use the same conduits of the energy system used for the wiring of power sockets However, this is only possible when using the BUS cable, Item 4669, with insulation voltage 300/500 Vdc Depending on the needs of the user and the type of building, the load control actuators may be installed: 1. in DI distribution board, if it is not required to display and reactivate the load directly in the room where the load is located; 2. near each current socket for the load to be controlled, to ensure the possibility of controlling the status and/or forcing the load PHYSICA IMIT The maximum number of devices that can be connected to the BUS (central unit for load management, actuator, power meter, and pulse counter interface) depends on the total absorption of the same, and on the distance between the connection point and the power supply If the system uses the same cable as the Automation/temperature control system, the calculation of the maximum number of devices must be performed taking into account the general absorption of the same For the purpose of the above calculations, the table shows the current absorbed by each device MAXIMUM UMBER OF ACTUATORS The Central Unit for oad Management can control up to 63 actuators (appliances or electric loads) If the system is solely dedicated to oad Management, or if it shares the same BUS line of the Automation/ Temperature control system, the number of actuators shall depend on the limit of the available current ITEM DEVICE ABSORPTIO FROM BUS F521 Central unit for load management 28 ma F522 Actuator with probe 30 ma F523 Basic actuator 10 ma HD/HC/HS///T4672 Flush mounted actuator 10 ma H4684-4684 - AM5864 Touch screen 3.5 80 ma HD/HC/HS4690 Multimedia Touch screen 10 50 ma F520 Bus meter with toroids 35 ma Pulse counter interface 7.5 ma HD/HC/HS///T4673 oad control panel 7 ma HD/HC/HS///T4685 ocal Display 60 ma F524 Energy data logger 30 ma 308 MY HOME

1. The length of the connection between the power supply and the furthest device cannot exceed 250 m Actuator Junction box Home automation distribution board Furthest device 2. The total length of the connections must not exceed 500 m (extended cable) Actuator Junction box Home automation distribution board MY HOME 309

PRI PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma GEERA RUES FOR ISTAATIO oad control management and consumption display In order to ensure optimum distribution of the currents on the BUS line, it is recommended to position the power supply in an intermediate position A A B B With E46ADC power supply: A = 250 m max B = 250 m max A + B =500 m The maximum current supplied by the power supply is: 1200 ma With power supply: A = 250 m max B = 250 m max A + B =500 m The maximum current supplied by the power supply is: 600 ma OTE: If a UTP5 cable is used instead of a BUS 4669 cable, distances must halved. 310 MY HOME

COFIGURATIO oad control management and consumption display The load management control and consumption display systems must be correctly configured to ensure that they can operate correctly, and that each item can perform the desired function The mode of configuration must be the physical one The physical configuration entails interaction with the devices - pulse counter interface (Item ), bus meter with 3 inputs for toroids (Item F520), central unit for load management (Item F521), load control actuators (Item F522, F523, The products may be split in two //T/HC/HS/ HD4672) and classes: consists in physically connecting 1. Pulse counter interface (item the connection components, called ), Bus meter with 3 inputs for configurators to the appropriate toroids (item F520), Central unit for housings of the devices load management (item F521) All The configurators have different these devices have an address from numbers, letters, colours, or graphics 1 to 127 COFIGURATOR SOCKET COFIGURATORS USED A1 is the configurator indicating the hundreds 0, 1 A2 is the configurator indicating the tens From 0 to 9 A3 is the configurator indicating the units From 1 to 9 A3-Ta From 1 to 9 (a configurator must be in this housing) A3-Tb From 1 to 9 A3-Tc From 1 to 9 WARIG: The 0 configurator in A3-Tb, A3-Tc indicates that the toroid input is not being used. A3 or A3Ta cannot be equal to 0. In the case of the bus meter with 3 inputs for toroids, item F520, if only one toroid is used, this must be connected to A3-Ta. Configuration examples: For bus meter with three inputs for toroids, item F520, and pulse counter interface, item : VAUE OF COFIGURATORS ADDRESSES WARIG: The devices in this class must be a different address from each other: for example, there cannot be Bus meter with toroids A1 A2 A3-Ta A3-Tb A3-Tc A1 A2 A3-Ta A3-Tb A3-Tc 0 0 1 2 3 1 2 6 7 0 Toroid connected to Ta with address 001 Toroid connected to Tb with address 002 Toroid connected to Tc with address 003 Toroid connected to Ta with address 126 Toroid connected to Tb with address 127 o toroid connected to Tc a pulse counter interface and a bus meter with three inputs for toroids with the same address. Also two toroids cannot have the same address. In case two consumption/load control devices are installed on an automation or temperature control bus, the configured addresses are not in conflict with the other devices on the system: a temperature control probe configured with address 11 is not in conflict with a bus meter with 3 inputs for toroids with address 11. Pulse counter interface A1 A2 A3 G M SM 0 0 4 Pulse counter interface address 004 It is possible to manage up to 20 lines (toroids) maximum per power supply. Example: 6 meters for 3 lines plus 1 meter for 2 lines (total 20). MY HOME 311

COFIGURATIO oad control management and consumption display 2. oad control actuators: The actuators may be used both as automation actuators and EERGY MAAGEMET actuators The configuration in automation mode follows the same rules outlined in the automation guide (see the device TECHICA SHEETS); the configuration in Energy Management mode requires a progressive address programs in the touch screens, and from 1 to 63 define the disconnection priorities for These addresses are used in the the controlled load appropriate configuration software COFIGURATOR SOCKET COFIGURATORS USED P1 is the configurator indicating the tens From 0 to 6 P2 is the configurator indicating the units From 0 to 9 Configuration examples: For actuator 16 A with probe Item F522 and actuator 16 A Item F523: Actuator 16 A with probe Actuator 16A COSUMPTIO DISPAY COFIGURATIO After installing the devices (Pulse counter interface, item, bus meter with 3 inputs for toroids, Item F520, central unit for load management, Item F521), an address must be assigned using physical configurators (A1, A2, A3) This address will then be used in the software for the configuration of the user interfaces (e g software for the configuration of the 3 5 touch screen) For more information see the relevant product technical sheet 312 MY HOME VAUE OF COFIGURATORS A P M P1 P2 PF 0 1 A P M G P1 1 P2 0 ADDRESSES Address priority 01 Address priority 10 OAD COTRO SYSTEM COFIGURATIO After installing the devices and configuring the actuators, it is necessary that the central unit for load management acquires the actuators on the bus, and the corresponding priorities configured For more information see the technical sheet of the central unit for load management, item F521, and the TECHICA SHEET for the actuators WARIG: In the case of consumption display/ load control actuators installed on an automation or temperature control bus, and configured also in automation mode (A, P...), the load control actuator must not have the same address as another actuator on the automation bus. Example: if actuator F411/1 A = 1 P = 1, then actuator F522 cannot be configured with P=1. SYSTEM EXPASIOS The energy management system is a very flexible system, for the installation of the devices on the automation/ temperature control bus, or for creating a system solely dedicated to energy management, with dedicated power supply in general, all energy management devices may be installed on each bus branch and on each expansion, provided this is allowed by the absorption calculations The only exceptions are the actuators, which, when configured in automation mode, during system expansions follow the same rules of the automation bus (automation technical guide)

AVAIABE FUCTIOS DEVICES Power bus meter with 3 inputs for toroids Central unit for load management Actuator 16 A with current probe Actuator 16A Flush mounted Actuator 16 A Pulse counter interface oad management panel I A1 A2 A3 G M SM OUT Visualisation oad control Diagnostic 1) OTE 1) : in combination with additional toroid, item AVAIABE FUCTIOS DEVICES ocal display Touch screen 3,5 Touch screen 10 Energy data logger Webserver Visualisation oad control Diagnostic 1) MY HOME 313

PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma A1 A2 A3 G M SM A1 A2 A3 G M SM WIRIG DIAGRAMS Display of electricity, water and gas consumptions ITEM RCCD MCB1 F520 DESCRIPTIO General switch 4 A MCB switch Compact power supply Bus meter with three inputs for toroids Toroid 3.5 / Multimedia 10 Pulse counter interface WARIG The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 Each F520 is supplied as standard with one toroid, item To the other users The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended. IG MGT1 4A Modem Router/ Switch PRI F520 A3 TA = 1 A3 TB = 0 A3 TC = 0 F524 BUS/ Switchboard or distribution board I OUT A3 = 2 M = 1 SM = 0 I OUT A3 = 3 M = 3 SM = 0 Zener Barrier/Galvanic insulation Barrier 1) OTES: 1) the barrier must meet the Atex requirements and must be installed outside the Atex area. Gas meter with pulse output Water meter with pulse output 314 MY HOME

PRI PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma Display of electric consumptions on several lines ITEM F520 RCCD MCB1-5 MCB6 DESCRIPTIO Compact power supply Bus meter with three inputs for toroids Toroid 3.5 / Multimedia 10 General switch inear protection switch 4 A MCB switch WARIG The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended. IG MGT1 MGT2 MGT3 MGT4 MGT5 Socket line 1 Socket line 2 ine 3 lighting ine 4 appliances ine 5 Temperature control (hot and cold) MGT6 F881A/4 F520 A3 TA = 1 A3 TB = 2 A3 TC = 3 F520 A3 TA = 4 A3 TB = 5 A3 TC = 6 Switchboard or distribution board BUS/ To other devices if present MY HOME 315

PRI PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma A1 A2 A3 G M SM WIRIG DIAGRAMS Display of produced and consumed energy WARIG ITEM F520 RCCD MCB1-2 DESCRIPTIO Compact power supply Bus meter with three inputs for toroids Toroid Pulse counter interface 3.5 / Multimedia 10 General switch MCB protection switch If a photovoltaic system and a thermal solar system for the production of energy and hot water are installed, by using energy measurement devices and the pulse counter interface the user can display the energy produced, or the amount of heated water on the touch screen. The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item, for current reading Wh Photovoltaic generator string The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended. Input/output meter Wh MGT1 IG Inverter String distribution board + + MGT2 F520 F520 A3 TA = 1 A3 TB = 0 A3 TC = 0 BUS/ A3 TA = 2 A3 TB = 0 A3 TC = 0 To other devices if present A3 = 3 M = 3 SM = 0 I Water meter with pulse outout Storage battery OUT 316 MY HOME

PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma Display of produced and consumed energy in exchange mode on location WARIG ITEM F520 RCCD MCB1-3 DESCRIPTIO Compact power supply Bus meter with three inputs for toroids Toroid 3.5 / Multimedia 10 General switch MCB protection switch In the presence of a photovoltaic panels system configured for a delivery of energy in local exchange mode, the bus meter with 3 inputs for toroids can be installed as shown in the figure: one toroid measures the current produced by the photovoltaic panels, the other the home consumption. WARIG: avoid fitting the measuring toroid directly on the main bidirectional meter. The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item, for current reading The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended Wh Production meter Photovoltaic generator string Input/ output meter Wh MGT1 Inverter String distribution board MGT2 + + IG MGT3 F520 PRI A3 TA = 1 A3 TB = 2 A3 TC = 0 BUS To other devices if present MY HOME 317

-1 +2-1 +2-1 +2-1 +2 +3 +3 +3 +3-2 -2-2 -2-3 -3-3 -3 1 C C 2 3 4 18.0 C 13 : 38 Ven 07 Gen -1-1 +2 +2 +3 +3-2 -2-3 -3 OK 18.0 C 13 : 38 Ven 07 Gen OK 1 2 3 4 5 +3-3 +3-3 +3-3 A1 A2 A3 G M SM WIRIG DIAGRAMS Display of the consumption of thermal power / hot water by individual home ITEM E46ADC...4695...4692 F430/2 F430/4 DESCRIPTIO Power supply 4 zone central units probe with adjustment knob 2 relay DI actuator 4 relay DI actuator Pulse counter interface 3.5 / Multimedia Touch Screen 10 In an establishment with central heating, by connecting a Pulse counter interface to the pulse output of the meter of a My Home system, it is possible to display on the touch screen the data made available by the meter (water consumption of the individual home, thermal power). The meter must be have pulse outputs, and must be installed at the input of the distribution manifold. WARIG The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 The following 4 zone central units may be installed: - HC/HS4695 AXOUTE - //T4695 IVIG/IGHT/IGHTECH - AM5875 MATIX Home n ZOE 3 ZOE 2 +1 OFF 4692 4692 +1 OFF The following probes with knob may be installed: - HC/HS4692 AXOUTE - //T4692 IVIG/IGHT/IGHTECH - AM5872 MATIX 23.7 ZOE 4 ZOE 1 C +1 OFF 4692 4695 Home 2 ZOE 3 ZOE 2 +1 OFF 4692 4692 +1 OFF Solenoid valve Solenoid valve Solenoid valve Solenoid valve Home 1 ZOE 4 23.7 ZOE 1 C +1 OFF 4692 4695 Central boiler F430/2 F430/4 E46ADC...4695 M Mixing valve Meter Main solenoid valve Mixing valve management central unit 1 2 3 4 1 2 3 4 5 ART. F430/2 ART. F430/4 C1 C2 C1 C2 C3 C4 C OK BUS/ +1-1 +2-2 OFF...4692...4692...4692 +1-1 +2-2 OFF +1-1 +2-2 OFF A3 = 1 M = 2 SM = 0 I OUT OTE: the pulse counter interface is recommended (M=2) to detect the thermal power 318 MY HOME

PRI PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma oad control management with total consumption display ITEM DESCRIPTIO WARIG F521 F523 RCCD MCB1...4672 Compact power supply Central unit for load management 16 A 1 M DI basic actuator Toroid 3.5 / Multimedia Touch 10 General switch 4 A MCB switch Flush mounted actuator The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 The following 2 module flush mounted 16 A actuators may be installed - HC/HS/HD4672 AXOUTE - //T4672 IVIG/IGHT/IGHTECH General MCB switches must be selected depending on load absorption The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended MGT1 MGT2 Each F520 is supplied as standard with one toroid, item, for current reading IG oad oad oad...4672 Touch Screen A3 = 1 P = 0 TO = 5 F521 F523 F523 A = 0 P = 0 M = 0 P1 = 0 P2 = 2 A = 0 P = 0 M = 0 P1 = 0 P2 = 1 A = 0 P = 0 M = 0 P1 = 0 P2 = 3 BUS/ Switchboard or distribution board MY HOME 319

PRI PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma WIRIG DIAGRAMS oad control management with total display, of loads and diagnostics ITEM F521 F523 F522 RCCD MCB1 DESCRIPTIO Compact power supply Central unit for load management 16 A 1 M DI basic actuator Actuator 16 A with probe Toroid 3.5 / Multimedia 10 General switch 4 A MCB switch WARIG The following s may be installed: - H4684 AXOUTE - 4684 IVIG / IGHT / IGHT TECH - AM5864 MÀTIX - Multimedia HD/HC/HS4690 General MCB switches must be selected depending on load absorption Each F520 is supplied as standard with one toroid, item, for current reading MGT1 MGT2 The general switch RCCD must be selected depending on general absorption. For better safety and comfort, the installation of an additional STOP&GO device is also recommended F522 actuator 16 A with integrated current probe, capable of measuring the consumptions of the controlled load. By connecting a toroid, item to the device, it is possible to measure the earth leakage current and display the load status on the Touch screen. IG oad oad oad oad F521 F522 F523 F522 F522 A3 = 1 P = 0 TO = 5 A = 0 P = 0 M = 0 P1 = 0 P2 = 2 PF = 5 A = 0 P = 0 M = 0 P1 = 0 P2 = 1 A = 0 P = 0 M = 0 P1 = 0 P2 = 3 PF = 0 A = 0 P = 0 M = 0 P1 = 0 P2 = 4 PF = 0 BUS/ Switchboard or distribution board 320 MY HOME

PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma PRI: 220 240 V~ 185 175 ma 50/60 Hz : 27 Vdc 600 ma Three-phase and one-phase load control management ITEM F521 F523 MCB FC4A... 380 Vac R S T DESCRIPTIO Compact power supply Central unit for load management 16 A 1 M DI basic actuator Toroid MCB switch AC contactor WARIG General MCB switches must be selected depending on load absorption The contactor must be selected depending on the absorption of the load The three-phase line must be balanced R S T MGT1 MGT2 R Single-phase load PRI F521 A3 = 1 P = 1) TO = 1) F523 A = 0 P = 0 M = 0 P1 = 0 P2 = 1 F523 A = 0 P = 0 M = 0 P1 = 0 P2 = 2 BUS/ 1 F521 F523 PRI A3 = 1 P = 1) TO = 1) A = 0 P = 0 M = 0 P1 = 0 P2 = 1 R FC4A... BUS/ 2 F521 F523 PRI A3 = 1 P = 1) TO = 1) A = 0 P = 0 M = 0 P1 = 0 P2 = 1 BUS/ 3 Three-phase load OTE: 1) the configurators must be selected depending on the rated power MY HOME 321