Safer.Smarter.Tyco. Watermist fire protection Technology you can trust



Similar documents
Mission-critical fire protection HI-FOG for data centres

- Save lives and reduce material damage

Fire Protection of Data Centres

- Save lives and reduce material damage

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Watermist fire suppression systems for commercial low hazard occupancies

For Data Center and Control Room Applications

For Data Center and Control Room Applications

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

How intelligent must an extinguishing solution be to keep fire virtual?

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

New Water Mist Solutions according to Annex B of CEN TS Guidelines for developing fire test procedures for Water Mist Systems

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

Mission-critical fire protection HI-FOG for large data centres

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

DATA CENTER FIRE PROTECTION

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications

Vehicle Fire Suppression Systems COPY ONLY

Alarm and Detection/Suppression

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

Dry Chemical Systems TWIN AGENT CAPABILITY

Morrison Bros. Co. General Product Specifications

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Automatic Fire Fighting Monitors

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Maintaining Fire Protection Systems

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Redefining Spray Technology

STEEL VESSELS UNDER 90 METERS (295 FEET) IN LENGTH 2012

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY

ANSUL. Restaurant Fire Suppression Systems ANSUL UL 300 ANSUL. LOW ph

Define Fire Stream. A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point

Challenges for Use of Fixed Fire Suppression Systems in Road Tunnel Fire Protection

Automatic fire-extinguishing systems for commercial cooking

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Total Solutions Providers for Fire & Security Systems

2014 Limited Plan Submittal Checklist

Transformer Deluge Systems

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

Fire Protection Pumps

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Inert Gas Extinguishing System Two Minute Discharge Study. Gene Hill, P.E. Brad Stilwell

Automation's Modular Containerized Datacenter Solutions

Certificate of Conformity Certificate num. Registration date Version Valid until

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

U l t i m a t e e f f i c i e n c y D re D ging

Pressure Vessels (Air Compressors) and LPG Tanks

All Products Brochure

Optimizing Tank Cleaning Operations

Alfa Laval PureBallast 3.1

Global Marine Solutions and Services from ship to shore Single source providers for Fire, Security, Life Safetynd Communications

ABSTRACT INTRODUCTION

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

mobile pipeline Bulk transportation and storage of energy gases

SPEEDROC D30. Surface Drill Rig for marble, granite, sandstone and limestone in the dimension stone industry.

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

HELI-DECKS & HELI-PORTS

H O M E F I R E S P R I N K L E R S S A V E L I V E S, M O N E Y A N D W A T E R A G U I D E F O R W A T E R P U R V E Y O R S

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Tailored Application Solutions

PERFORMANCE AT HAND. RED LINE Hand Portable Fire Extinguishers

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Data Center Solutions - The Containerized Evolution

THE SMARTER WAY RAIL SYSTEMS ENGLISH

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Fire Pump Plan Review March 2010

Transform your business. with gas-fuelled engines

HYDRA-GRENE - A Powerful Partner for the Industry

Notes. Material 1. Appropriate Flammable Liquids

Maximum uptime and optimum fire safety for your data center

Veenstra Group Your Partner

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

ENGINEERING SPECIFICATIONS

EFSN Training i Module Minutes

Together proudly facilitating the 2014 Storage Tank and Associated Facilities Fire Hazard Management Workshop. Date: JULY 2014

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Topics of the Presentation

Cost-effective solutions for all applications.

Transcription:

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

/ 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment safe with its high performance fire suppression products. The Tyco AquaMist systems are a versatile and highly efficient fire-fighting medium featuring unique nozzles which have been developed and approved for fire protection. When designing a fire protection system, the challenge is to select the right suppression system to match the risk. Tyco has the widest range of fire protection products on the market, including sprinklers, clean agent systems, watermist and others. We can help you make the right product choice to offer the best protection for the hazard at hand. Our AquaMist product range includes proven watermist solutions supported by over 100 years of expertise in fire protection. We offer three AquaMist options to suit different applications and better accommodate end users needs from industrial oil fryers, machinery spaces and cable tunnels to hospitals, commercial buildings and data centers. Our watermist systems safeguard lives and property, while saving water in usage. As part of a fire-protection toolbox, the AquaMist systems offer a simple and easy to use water-based fire suppression solution which is dependable, safe and carries comprehensive approvals. How the AquaMist systems work Through our expertize and knowledge, we can advise you on which system is best suited to the environment to be protected and the best specification to match the risk. We believe in customizing a solution to the application, not in a one-size-fitsall solution. Selecting the right watermist system is not only about extinguishing the fire, it is about caring for the contents of the building and minimizing water damage. It is also about optmizing budgets and protecting the reputation of the specifier. Ulf Fog

/ 4 / / 5 / Watermist Applications As part of your water protection armoury, the AquaMist range enables you to make the best choice and provide the most suitable protection. Because you have a choice, you can specify a solution where it is most applicable - with no compromise on performance or protection. AquaMist Application FM FM UL Performance based FM TS14972 FM VdS Mechanical Escalators IMO Performance Based FM FM Max Room Height 5 M 8 M 8 M N/A 4 M 5 M N/A 5 M 5 M 8 M Max Volume Unlimited 1280 m 3 1600 m 3 N/A Unlimited 260 m 3 N/A 2000 m 3 260 m 3 1040 m 3 Hotels Data Centers Heritage Buildings High Rise Buildings Hospitals Machinery spaces, total flooding Turbine Enclosures Special hazard Machinery spaces Stations Cable tunnel protection Library / Archives Rolling Stock Industrial Fryer Protection

/ 6 / / 7 / Ultra Low Flow Tyco International / 7 / Ulf MACHINERY PROTECTION CABLE TUNNEL HOSPITALS HOTELS The Ultra Low Flow system is a complete engineered solution which includes pumps, valves, discharge nozzles, pipes and fittings, all designed to function as one dedicated fire suppression solution. AquaMist ULF solution consists of: // A pump skid unit How it works The system operates at working pressures of 7 to 16 bar, producing droplets of water through an engineered discharge nozzle, with different nozzle types for different protected hazards. The fine mist generated following operation is designed to limit fire growth at an early stage, before the fire can fully develop. The benefits gained include up to a fivefold reduction in the water required, without any detrimental effect on fire fighting capability. Benefits Benefits can be found through lower water demands, translating into lower pressure loses, smaller diameter pipes and lower installation costs when compared to traditional sprinkler systems. As the system uses only water, it produces no adverse environmental impact. // Electrical control equipment // Discharge nozzles which are located around the protected area: AM4, AM24, AM27, AM29, AM30 // G-PRESS piping system // Optional FASTFLEX flexible hoses // Design & technical services // The ULF system is suitable for a variety of applications, for example machinery protection, heritage buildings and industrial fryers (also know as oil cookers) Quality and Safety Assured ULF AquaMist systems are supplied through authorized partners. Each partner is trained in the use of the SprinkCAD system software and in the design, installation and commissioning of systems. The ULF AquaMist training module enables system designs from risk assessment all the way through to material take offs. Authorized partners are fully supported by the Tyco technical services team and all Tyco Fire Protection Products are manufactured components and are of the highest quality. AM27 AM29

/ 8 / Fog / 9 / Fog MACHINERY PROTECTION ARCHIVE ESCALATORS ROLLING STOCK Tyco s FOG system reduces the consumption of water and pipe diameters whilst providing a fast and efficient method of fire protection for class A and B fires. AquaMist FOG solution consists of: // A pump skid unit and bank of cylinders // Electrical control equipment // Discharge nozzles which are located around the protected area // Design & technical services How it works The system operates at working pressures of 70 to 200 bar to produce droplets of small diameters at high speed. For each different protected hazard, optimized nozzles have been developed and tested. AquaMist FOG is based on principles of well established hydraulic technology. Spray heads are designed to discharge water in the form of watermist, with tiny drops creating a large effective cooling surface area of the fire and surrounding volume. The high speed of the droplets means that the mist can penetrate the hot fumes and reach the combustion area quickly. AquaMist FOG systems can be supplied with a standalone bank of cylinders, electric pumps and diesel pumps depending on the fire hazard and installation needs. Benefits AquaMist FOG systems are one of the best options when piping dimensions or pressure losses are critical, for example in applications such as older heritage buildings or libraries and archives, where excessive water damage and fragile infrastructure needs specialist care and attention. It gives outstanding fire suppression protection for turbine and transformer rooms, engine test cells, diesel engines and alternators, paint spray booths and mechanical escalators. It also provides fire control for computer rooms, occupied rooms and class A fires, archives, cable trays and telecommunication centers. Approved and Tested Solutions Our AquaMist FOG products are approved and certified so you know you are sourcing products which are approved and tested to the highest standards. Approvals are in place to prevent unsafe or risky products from entering the marketplace. Our solutions have been rigorously tested by a third-party, with on-going product auditing, to ensure standards are maintained. AquaMist FOG Nozzle AquaMist FOG Open Nozzle

/ 10 / / 11 / MACHINERY PROTECTION Tyco s AquaMist system is a revolution in Class B fire protection and features 100% machined stainless steel construction for superior strength, no internal moving parts for extreme dependability and multiple mounting options for ease of installation. AquaMist system consists of: // Bank of cylinders // Electrical control equipment // Discharge nozzles which are located around the protected area // Design & technical services How it works This system utilizes non-toxic and readily available extinguishing media (water and nitrogen). AquaMist s twin-fluid technology is safe for people and is environmentally-friendly and it is also inexpensive to recharge. The system provides a higher volume of smaller water droplets, spraying them further and is the high-performance fire suppression system specifically engineered to cover a wide range of industrial, commercial and institutional special hazard applications. It is constructed of industry-recognised, proven, components including an ASME/TPED approved stainless steel water storage tank. Capable of automatic detection and actuation and/or remote manual actuation, the system is installed and serviced by authorized distributors. Innovative solutions Just two supersonic atomizers create 1.5 trillion superfine water droplets per second, producing a combined surface area of 121 m2 (1302 ft2) per second. This is equivalent to the surface of an Olympic-size soccer field in one minute. Plus, the atomizers propel the droplets at high velocity throughout the combustion zone. The atomizer is the key to the effectiveness of the AquaMist system. Supersonic technology generates a high-velocity, low-pressure zone that draws a thin sheet of water into a primary atomization region. A conical supersonic wave then creates a zone of extreme acceleration and high shear-rate, breaking the sheet into atomized droplets. Benefits The system is faster with high-volume, high-velocity discharge which quickly fills spaces. It is also smarter and uses one-third the water of comparable highpressure systems. This system is listed and approved for the protection of flammable liquid hazards (FM) and extinguished all fire scenarios in the FM Protocol 5560. It is FM approved for spaces ranging from 4,591 to 36,727 cubic feet (130 to 1040 cubic meters). AquaMist Bank of Cylinders AquaMist Nozzle In terms of placement, the AquaMist system offers maximum flexibility. Atomizers can be mounted to the ceiling at heights from 3.0 to 8.0 meters (9.8 to 26.3 ft) and also to walls at heights from 2.0 to 5.0 meters (6.7 to 16.4 ft). Electrical or mechanical selector valve options allow protection of multiple hazards using a single system.

Safer.Smarter.Tyco. Global strength. Local expertise. At your service. WORLDWIDE HEADQUARTERS Tyco Fire Protection Products, 1400 Pennbrook Parkway, Lansdale, PA 19446, Tel: +1 215-362-0700, (Toll Free) Tel: +1 800-558-5236, Fax: +1 800-877-1295 www.tyco-fire.com Europe, Middle East & Africa Tyco Fire Protection Products Kopersteden 1, P.O. Box 198, 7500 AD Enschede, The Netherlands, Tel. +31 (0)53-428-4444 www.tfppemea.com Asia Pacific Tyco Fire Protection Products, 2 Serangoon North Avenue 5, #07-01, Singapore 554911 Tel. +65-6577-4360, Fax: +65-6481-8791 www.tyco-fire.com UNITED KINGDOM Tyco Fire Protection Products 5 Top Angel, Buckingham Industrial Park, Buckingham, UK MK18 1TH Tel: +44 1280 821229 www.tfppemea.com www.tyco-fire.com/aquamist Copyright 2013 Tyco Fire Products LP. All rights reserved