PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624



Similar documents
PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

RY2 miniature industrial relays

650W Single Output Power Supply

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

HERZ-Thermal Actuators

ACS-30-EU-EMDR-10-MOD

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Digital input modules

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

HM-W536 Install Guide

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Power Supplies 3. SDN-P DIN Rail Series

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ADM1TE 5/30A DIN rail single phase two wire energy meter

Cross-beam scanning system to detect slim objects. 100 mm in

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Single Output Switching Power Supply

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Radiant Temperature Sensor TY7321

User s Manual Before using the inverter, you need to read and save the safety instructions.

Absolute Rotary Encoder E6CP

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Power supply unit Model: PAC-SC50KUA

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Quick Connect. quick - simple - efficient.

Emergency lighting units EM powerled

Modular I/O System Analog and Digital Interface Modules

is then retained absolutely without interruption.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

DALI RC BASIC SO. Control unit Operating instructions

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

MCR1900 Media Converter 19-Slot Chassis

Telephone- and leased line modem for industrial applications TD-36

BITMAIN. APW PSU Series User Guide

DCS Input/Output Relay Card Series

Datasheet. Arrant-Light Oy. 120W DR Series

WD-AMX Water Detection Controllers

INSTALLATION INSTRUCTIONS

Telefon (+45) Telefax (+45) Installation and operating manual

ICON Server box installation manual Rev. 1.1

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ST Series POWER SUPPLIES USER INSTRUCTIONS

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

AIS750 Series Alarm Annunciator

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Thyristor-controlled power supplies and battery chargers

CompactLogix Power Supplies Specifications


CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Digital Keypad Use s Manual

RRV934. Multi-controller. Synco living

SKR - industry relay

TrueAlarm Fire Alarm Systems

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Charge Regulator SCR 12 Marine

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

PCS0100en Persy Control Services B.V. Netherlands

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Section D..General Auto Electrical Corporation

Product and functional description

Solid-State Timer H3G

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HMI display Installation Guide

Online UPS. PowerWalker VFI 1000R/1U

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

TX OPEN RS232/485 module

SYSTEM 4C. C R H Electronics Design

Water Leak Detection System

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Thermistor motor protection

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Adjustment functions for both span and shift have been incorporated

TIG INVERTER INSTRUCTION MANUAL

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Transcription:

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009

CONTENTS: 1. Technical description. 1.1. General description 1.2. Block diagram 1.3. Description of elements and power supply connectors 1.4. Technical parameters 2. Installation. 2.1. Requirements 2.2. Installation procedure 3. Monitoring of the power supply operation. 3.1. Optical signaling 3.2. Technical output 4. Service and operation. 4.1. Overload or short-circuit protection 4.2 Maintenance 1. Technical description. 1.1. General description. AC/AC PSAC 0624 power supply is used for supplying devices which require stabilized voltage of 24V (U1= 24,0VAC/ U2= 27,0VAC) and of total current efficiency equal to 6A@24Vac (150VA). The basic features of the power supply include: 10 outputs protected independently by fuses, any failure (short-circuit) in a circuit of any output causes burning of a fuse-element and isolation of circuit from DC supply. regulation of output voltage: in case of installation, when significant voltage drops at the resistance of power cables of receivers occur, it is possible to change a voltage value by U1/U2 jumper, independently for every AUX output. optical signaling of operation informing about the state of any output and/or any failure. AW technical output informing about any output failure (activation of SCP) used for remote control of operation protections: short-circuit (SCP), overload (OLP), overheat (OHP), metal casing (RAL 9003 color) with signaling panel and microswitch (TAMPER) indicating door (front) opening Information about additional equipment for PSAC 0624 power-supply: - AC/DC power supply module in the ABS casing, MSC 1512 (MSC 12V/1,5A or 24V/1A power supply, switched voltage) allows building 24Vac and 12Vdc/24 supply system. Information about types: Model PSAC 0424 PSU-U-24V/AC-4A/5/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSACH 0424 PSU-U-24V/AC-4A/5/FTA-TR-HC Description AC/AC 24V AC power-supply unit, with the total current capacity 4A@24V and switched output voltage 24,0V/27,0V. Equipped with the indication panel of AUX outputs status. Metal casing IP20 with an indication panel equipped with the TAMPER microswitch. AC/AC 24V AC power-supply unit, with the total current capacity 6A@24V and switched output voltage 24,0V/27,0V. Equipped with the indication panel of AUX outputs status. Metal casing IP20 with an indication panel equipped with the TAMPER microswitch. AC/AC 24V AC power-supply unit, with the total current capacity 4A@24V and switched output voltage 24,0V/27,0V. Equipped with the indication panel of AUX outputs status. ABS IP65 casing with equipped with the TAMPER microswitch. 2

1.2. Block diagram (fig.1). Fig.1. The block diagram of the power supply. 3

1.3. Description of elements and power supply connectors (tab.1, tab.2, fig.2). Table 1. Element no. [Fig. 2] Description [1] Isolating transformer [2] [3] LB5-A, LB5-B fuse block (tab 2) [4] TAMPER, contact of antisabotage protection (NC) [5] F switch in the power supply circuit (230V/AC) [6] L-N power-supply connector 230V/AC, PE protection connector Tab.1. The elements of the power-supply unit. Table 2. [3] Description of LB5-A and LB5-B elements COM-U1-U2 AC supply input (transformer isolation required) AUX1 AUX5 COM AC supply output, U1 or U2 Common contact (COM) AW GND failure technical output - NC (0V), OC type ground contact of AW output L1 L5 LED diodes (green) indicating L1=AUX1 output status etc. L AW F1 F5 LED diode (red) indicating failure of min. one output (fuse failure) Fuses in AUX circuits, F1=AUX1 etc. Jumper of AUX output voltage change (for each output separately): U1-U2 U2 dip switch installed, output voltage AUXx= U2 U1 dip switch installed, output voltage AUXx= U1 Tab.2. Contact and elements of LB5. 4

Fig.2. The view of the power supply 5

1.4. Technical parameters: - electrical parameters (tab.3) - mechanical parameters (tab.4) - operation safety (tab.5) - operation parameters (tab.6) Electrical parameters (tab. 3). Supply voltage 230V/AC (-15%/+10%) Supply frequency 50Hz (47 53Hz) PSU power P 150VA max. Current consumption 0,75 A max. (8,0 A cold boot ) Output voltage U1 : 23,0V 28,0V AC (100% load 0% load) U2 : 25,5V 31,5 AC (100% load 0% load) Voltage setting range U1/U2 (abrupt change) Voltage adjustment range no adjustment Output current 10x 0,6A for F1A fuses 5x 1,2A for F1,5A fuses Σ6,0A@24Vac max. or 5,5A@27Vac max. 2A max. for single AUX (F2A) 10x F1,0A fuse or 5x F1,5A fuse (fuse replacement from the set, only three SCP short-circuit protection AUX outputs used) - fuse failure fuse element replacement required 10x F1,0A or 5x F1,5A AC 24V circuit OLP overload protection 1x T3,15A AC 230V circuit Technical outputs: - AW LB5 output indicating the failure of one AUX output (fuse failure) - TAMPER output indicating opening of the power-supply casing Optical indication: LED L1 L5 diodes (green) LED LAW diodes (red) F fuse F1 F5 fuse - OC type, 50mA max. normal status: level hi-z, failure status: level L (0V) - microswitch, NC contacts (close casing), 0,5A@50V DC (max.) - outputs statusaux1 AUX5 Normal status = illumination Failure status = no illumination - Failure indication of min. one AUX output Normal status = no illumination Failure status = illumination T 1A/250V F1A/ 250V or F1,5A/250V Mechanical parameters (tab.4). Casing dimensions 215 x 230 x 63 (WxHxD) [mm] (+/- 2) Fixation 185 x 195 x Φ 6 x4pcs (WxH) Net/gross weight 2,8 kg/2,90 kg Casing color RAL 9003 Closing Cheese screw x 1 (at the front) Connectors Power-supply: Φ0,63-2,50 (AWG 22-10) Outputs: Ф0,41 1,63 (AWG 26-14) TAMPER output: wires, 30cm Notes The casing is distant from the assembly surface so that cables can be installed Operation safety (tab.5). Protection class PN-EN 60950-1:2004 Protection class PN-EN 60529: 2002 (U) Electrical strength of insulation: - between input (network) circuit and output circuits of power-supply (I/P-O/P) - between input circuit and PE protection circuit (I/P-FG) - between output circuit and PE protection circuit (O/P-FG)) 6 I (first) IP20 3000 V/AC min. 1500 V/AC min. 500 V/AC min.

Insulation resistance: - between input circuit and output or protection circuit 100 MΩ, 500V/DC Operation parameters (tab.6). Operation temperature Storage temperature Relative humidity Vibrations during operation Impulse waves during operation Direct isolation Vibrations and impulse waves during transport -10ºC...+40ºC +5ºC...+40ºC 30%...90%, without condensation Unacceptable Unacceptable Unacceptable According to PN-83/T-42106 2. Installation. 2.1 Requirements. The buffer power-supply shall be mounted by the qualified installer having appropriate (required and necessary for a given country) permissions and qualifications for connecting (operating) 230V/AC installations and low-voltage installations. The device shall be mounted in closed rooms, according to the environment class II, of the normal air humidity (RH=90% max. without condensation) and the temperature within the range from -10 C to +40 C. The power-supply shall operate in a vertical position so that free and convectional air flow through ventilating holes of the casing is guaranteed. Before installation is started, the balance of the power-supply load shall be performed. During the normal operation, the sum of currents collected by receivers shall not exceed I=6,0A@24Vac. It is acceptable to change values of fuses to other than original, if not all outputs of power supply of LB5 block are used and S= 150VA max. is not exceeded. (Σ6,0A@24Vacmax and current of single 2A/AUX output). As the power-supply is designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection in the power supply circuit shall be guaranteed. Moreover, the user shall be informed about the method of isolation of the power supply from the power voltage (usually through assignment and marking of an appropriate fuse in the fuse-box). The electrical system shall be made in accordance with valid standards and regulations. 2.2 Installation procedure. 1. Before installation is started, the voltage in the 230V power-supply circuit shall be isolated. 2. The power-supply shall be mounted in a selected location and connection cords shall be lead. 3. The power cables (~230Vac) shall be connected to L-N terminals of the power supply. The earth conductor shall be connected to the terminal marked by the earth symbol. The connection shall be made by means of a three-core cable (with a yellow and green PE protection wire). The power cables shall be lead to appropriate terminals of the connection board through bushing. The circuit of the shock protection shall be performed with a particular care, i.e. the yellow and green protection wire of the power cable shall be connected from one side to the terminal marked by the symbol of in the casing of the power-supply. Operation of the power-supply without the properly made and fully operational circuit of the shock protection is UNACCEPTABLE! It can result in failure of devices and electric shock. 7

4. Connect the receivers wires to connects: a) AUXx-COM LB5-A and LB5-B if 10x 0,6A are used (F 1A fuse). b) AUXx-COM LB5-A if 5x 1,2A are used (F1 fuse, 5A, LB5-B bloch should be left unused). 5. If necessary, connect the conductors from the equipment to the technical outputs: - AW LB5 signalization of fuse failure (LB5 block output) - TAMPER signalization of power-supply unit opening 6. As there are significant voltage drops at the resistance of power cables of receivers during installation, it is possible to adjust a voltage value by (abrupt) correction of voltage value by U1/U2 dip switches. Output voltage value change is independent for every AUX output. 7. Activate the ~230V/AC supply 8. Check optical indication of power supply operation: LED L1-L5 (green) diodes shall light continuously. 9. Once the tests and control operation have been completed, lock the casing. 3. Monitoring of the power-supply operation. The power-supply is equipped with the optical signaling of operation modes. Voltage at the outputs of the power supply is indicated by lighting of green LEDs at the front panel of the device. A failure is indicated by the red LED [!] AW. The power supply mode can be remotely controlled by AW technical output [2]. 3.1 Optical signaling (fig.3.). Green LED s 1.5 indicate the power-supply mode at AUX1..AUX5 outputs. If power supply is lost at an output (fuse blow), a correspondent LED stops lighting (L1 for AUX1, L2 for AUX2, etc.). The red LED [!] AW indicates any failure of at least one AUX output (the number of the output is indicated by a green LED). Fig.3. The view of PSAC 0624 panel. 3.2 Technical outputs: The power supply is equipped with indication outputs which enable passing information about failure or sabotage. AW output indicates fuse failure (LB5 block outputs). The AW technical output is isolated from frame (GND) during proper operation of LB5, and if any fuse is damaged, the output is shorted to frame. Such state is indicated by a red LED on LB5 block. TAMPER: output indicates opening the power-supply unit, output as volt-free contacts which indicate power-supply unit door status, unit closed: NC, unit opened: NO. 8

4. Service and operation. 4.1 Procedure in case of short-circuit (activation of SCP) of the power supply output. The AUX1 AUX5 outputs have short-circuit protection through application of fuses (fuse-elements). If a failure occurs, the fuse shall be replaced (the same as the original). It is acceptable to change values of fuses to other than original, if not all outputs of power supply of LB5 block are used and S= 150VA max. is not exceeded. (Σ6,0A@24Vacmax and current of single 2A/AUX output). If the power-supply is overloaded by the current exceeding Σ6,0A@24Vac (110% 150% P), F fuse in the 230Vac is damaged and/or F1-F5 fuses. In case of the failure the fuse shall be replaced (the same as original). 4.2 Maintenance. All maintenance operations can be performed after the power supply is disconnected from the power network. As for the power supply, it is not necessary to perform any special maintenance operations, but if the power supply interior is significantly dusty, it shall be vacuum-cleaned by compressed air. In case of fuse replacement, the spare parts shall be the same as original ones. 9

Pulsar K.Bogusz Sp.J. Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsarspj.com.pl, sales@pulsarspj.com.pl http:// www.pulsarspj.com.pl WEEE MARK The waste electric and electronic equipment shall not be discarded together with common home waste materials. According to the WEEE valid in EU, particular methods of utilization shall be applied for the waste electric and electronic equipment. WARRANTY 24 months since the sale date, 36 months since the production date. THE WARRANTY IS VALID ONLY after presenting the invoice of the sale to which the claim refers. 10