Certificate of shape stability



Similar documents
YFS Automotive Systems, Inc. Supplier Packaging Guidelines

March 14, Installation of Bay, Bow and Garden Windows

SINTEF Building and Infrastructure. Contents

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

COIL PAC. Subec AB, Sprängarvägen 16, Saltsjö-Boo, Sweden, Tel.: , Fax: , info@subec.se

Rack installation instructions

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

2016 IDEERS Rules for Graduate Teams. The List of Rule Revisions

Sheet Metal Bending. By- Prem Mahendranathan

39HQ Airovision Air Handling Units

Technical handbook Panel Anchoring System

POLLUX TP-703VLM. Pallet

1. Kyle stacks 30 sheets of paper as shown to the right. Each sheet weighs about 5 g. How can you find the weight of the whole stack?

building applications copper - redefined

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Copyright Voluntary Interindustry Commerce Solutions Association. All rights reserved.

POLIMAT C series palletizers

0.3 mm Contact Pitch, 0.9 mm above the board, Flexible Printed Circuit ZIF Connectors.

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

SIGRAFLEX . Properties. Applications

For Components PIERBURG S.A.

B) 286 m C) 325 m D) 367 m Answer: B

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Grooved gaskets. Types of gaskets

Acceleration due to Gravity

Physics 2A, Sec B00: Mechanics -- Winter 2011 Instructor: B. Grinstein Final Exam

HORIZONTAL INSTALLATION

Detailing of Reinforcment in Concrete Structures

Guidance Note. Plant and Machinery. Relevant legislation. What is the legal definition of a pallet? A pallet is defined in BS ISO 445 as follows:

Installation Instructions

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Mounting Instructions for SP4 Power Modules

FALL PROTECTION- Part 2 SELF INSPECTION CHECKLIST

Natural Convection. Buoyancy force

Butt Fusion Welding of HDPE Pipes Work Procedure

3d space container challenge

Phys222 Winter 2012 Quiz 4 Chapters Name

Installation Manuals Version n. 01 of 14/06/2013

Roll Handling By Jeff Damour CONVERTER ACCESSORY CORPORATION Wind Gap, PA USA

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

bi directional loading). Prototype ten story

SPM FIS B-Net Assembly Instructions. Installation Recommendations. 2009, World Cup Supply, Inc SPM B-Net Assembly/Installation

FTC DIY Mountain Build Guide

General Allowances for Insulation & Cladding

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

PS6500 Storage Arrays Rack Mount Instructions

IPR Äspö Hard Rock Laboratory. International Progress Report. Temperature Buffer Test. Report for retaining plug and anchoring

HP Color LaserJet CM2320 MFP Series Paper and Print Media Guide

Super Slider ADJUSTABLE FROM Model #HD26229

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Physics: Principles and Applications, 6e Giancoli Chapter 4 Dynamics: Newton's Laws of Motion

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

PHYSICS 111 HOMEWORK SOLUTION #10. April 8, 2013

Contents. Cargo securing instructions

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Rear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003

42U/45U 28" Wide Rack Installation & Service Guide

VOLUME AND SURFACE AREAS OF SOLIDS

HOOKE S LAW AND OSCILLATIONS

ELASTFLEX TECHNICAL DATA. STADIUM Building height: 38mm Board: 14 x 215 x 2200mm Format: 3-Strip EDUCATION ARENA. boensport.com

EDUH SPORTS MECHANICS

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

MONDOATHENS BASKETBALL SET (Reference PK110)

PAAM COMMERCIAL PRIVATE LIMITED

2200 SERIES COMMON DRIVE PACKAGE Special Capabilities Specification Sheet

Liste der verwendeten Prüfmittel List of used test equipment

Physics 11 Assignment KEY Dynamics Chapters 4 & 5

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Introduction... 3 Setting the Combination... 4 Securing the DEFCON CL... 5 Locking the DEFCON CL to your Notebook Computer...

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

The load carrier system designed for professionals

Simple Machines. What are simple machines?

Rack Installation Instructions

Product and Package Testing Requirements for Transportation, Storage and Delivery

WATERPROOFING OF WET ROOMS

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

METHOD OF STATEMENT FOR STATIC LOADING TEST

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Fall Protection Susan Harwood Grant Training Program 2013 Fall Arrest. OSHA Susan Harwood Training - AGC

MERO Floor Systems - CleanRoom

Transformer oil cooler ALFA A02

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

OptiLedge Implementation Handbook

Lab 8: Ballistic Pendulum

Generative Drafting. Page DASSAULT SYSTEMES. IBM Product Lifecycle Management Solutions / Dassault Systemes

Portable Digitilt Tiltmeter

Lecture 17. Last time we saw that the rotational analog of Newton s 2nd Law is

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

ELEVATOR TRAVELING CABLE - DESIGN EVOLUTION

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

How to build a Pizza Oven in 4 days

MD5-26 Stacking Blocks Pages

POLE MOUNT SYSTEM-3 INSTALLATION

How To Test A Base Axe

Transcription:

1. 2. 3. 4. 5. 6. Ref. transp. packaging unit: Certificate of shape stability Ref. measuring report: Deltarack - 20120810002 Company: Deltarack Performed test: Acceleration test according to: Be RD of April 27th 2007, VCAT-40509:2010, Date: 10-08-2012 EN12195-1:2010 Description of the tested transport packaging unit Description: Deltarack 4BL - edge flange The load unit consists of a wooden rack type 4BL, containing two concrete blocks of 750kg. Two edge flanges are placed against the concrete blocks. The flanges and the blocks are joined with the rack by two diagonal straps. Two vertical straps are used to prevent tilting of the blocks. Primary packaging: Concrete plate Secundary packaging: Deltarack B4L Tertiary packaging: Stretch film: Stretch hood: Shrink hood: Straps: Add transport packaging: Anti slip up the pallet: Anti slip up on layer(s): Stacking pattern: / 2 vertical straps, 2 diagonal Straps Pallet_type: / # Layers: 0 Height [mm]: 1200 Weight[kg]: 1600 7. 8. Length - LP [mm]: 2000 Width - BP [mm]: 770 Name and signature responsible of the packaging: Test conditions: Relative humidity: 20% - Temperature: 65 C - Sliding of the pallet is prevented mechanically. 9. Picture in the BP-direction after the test. Picture in the LP-direction after the test. 10. Conclusions: No conclusions The tested load unit is shape stable in the LP-direction at 0.8g under the specified test conditions. 11. Name and signature responsable of the test: Ing. J. Dendauw ESTL nv - Wafelstraat 46-8540 Deerlijk - Belgium - T: +32 477/620 614 - F: +32 56/77 86 00 info@estl.be - http://www.estl.be - BE0818.634.666 - RPR Kortrijk

ESTL nv is a spin-off from: TEST REPORT of the ACCELERATION TEST based on RD of April 27th 2007, EN12195:2010, VCAT-40509:2010 Ref. transp. packaging unit: Deltarack 4BL - edge flange Ref. measuring report: Deltarack - 20120810002 ESTL nv - Wafelstraat 46-8540 Deerlijk - Belgium - T: +32 477/620 614 - F: +32 56/77 86 00 info@estl.be - http://www.estl.be - BE0818.634.666 - RPR Kortrijk

Specifications of the test Client Company: Deltarack Address: Lodewijk De Konincklaan 310 2320 Hoogstraten België Contact pers.: Jan Servaes Tel. nr.: 0032 477 59 56 70 Fax nr.: 0 Mob. nr.: 0 E-mail: info@deltarack.com Test details: Test facility: Test responsible: Test equipment: ESTL nv, wafelstraat 45, 8540 Deerlijk, België Ing. Jelle Dendauw VCAT/ Acceleration bench /090530 Test date: 10-08-2012 People attending: Jelle Dendauw (ESTL), Jan Servaes (Deltarack) Temperature [ C]: 65 Rel. humidity [%]: 20 Load conditions: Sliding of the load unit is prevented mechanically. Attached documents to the report: / Goal of the acceleration test According to the Belgian RD* of April 27th 2007 and the EN12195:2010, a load securing layout has to be capable of withstanding certain forces of inertia. These forces amount to 0,8g in forward direction, 0,5g in rearward direction and 0,5g in the sideward directions. The acceleration test allows for an unambiguous assessment of a certain load unit, secured in a specified manner, with the rules and regulations of the Belgian RD. A load unit is placed on a platform and is secured in the correct orientation and according to a specified securing layout. The platform is then accelerated at 0,8g to imitate the influence of the forces of inertia originating from the forward deceleration as prescribed in abovementioned RD. The stability of the load unit is then assessed. If the load unit is deemed stable, it is rotated 90 degrees, together with the securing layout. Next, the platform is accelerated at 0,5g to imitate the influence of the forces of inertia originating from the sideward acceleration prescribed in abovementioned RD. After this test the stability of the load unit is assessed once again.

Report specifications Report: 20120810-002 Date: 10-08-2012 Author: Dendauw Jelle Company: Deltarack Contact: Jan Servaes Pallet name: Deltarack 4BL - edge flange Conclusions Acceleration: 0.6 Direction: LP The pallet behaves stable? Type of deformation: The load unit is behaving shape stable at 0.6g in the LP-direction (The lashing is only a security feature and isn't supporting the rack.) Acceleration: 0.8 Direction: LP The pallet behaves stable? Type of deformation: The load unit is behaving shape stable at 0.8g in the LP-direction (The lashing is only a security feature and isn't supporting the rack.) 20120810-002 Deltarack Page 1 / 3

General remarks and conclusions Conclusion: - The pallet is behaving shape stable up to 0,8g in the LP-direction. Results acc dir B A R 0.6 LP 0 0 0.2 0.8 LP 0 0.6 0.6 Containment force short side [kg]: Top: Mid: Bottom: acc dir B A R 0.6 LP 0 0.2 0.2 0.8 LP 0-0.6 0.6 Containment force long side [kg]: Top: Mid: Bottom: acc dir B A R 0.6 LP 0 0 0.2 0.8 LP 0 0.6 0.6 Stretch foil specifications Stretch film: / Thickness [µm]: 0 Producer: / Pre-stretch[%]: 2nd Stretch[%]: Stretch wrapper: Weight (g): Practical stretch [%]: Pallet roping: Overlap when going up [%]: Overlap when going down [%]: Position of the roping [mm]: Foil overlap at the top [mm]: # Wrappings: The measurement protocol is available upon request. 20120810-002 Deltarack Page 2 / 3

Pallet specifications Name of the pallet: Deltarack 4BL - edge flange The load unit consists of a wooden rack type 4BL, containing two concrete blocks of 750kg. Two edge flanges are placed against the concrete blocks. The flanges and the blocks are joined with the rack by two diagonal straps. Two vertical straps are used to prevent tilting of the blocks. Pallet type: / Stacking pattern: / # Layers: 0 Cases per layer: 0 Tie sheet between load and pallet Tie sheet on top of layer(s): LP [mm]: 2000 BP[mm]: 770 Weight [kg]: 1600 Height [mm]: 1200 Primary packaging Name.: Type: / Concrete plate 813 1800 143 Secondary packaging Name: Deltarack B4L Theor. head space [mm]: Gross weight [kg]: 1527 Compression force [N]: Fluting type: / Prim units per sec. unit: 1 Additional packaging 2 vertical straps, 2 diagonal Straps 1200 770 2000 20120810-002 Deltarack Page 3 / 3

Guideline accompanying the measurement report or certificate General remark Some fields can be left blank, if they are irrelevant or if the described value was not measurable. List of used abbreviations Abbreviation Explanation BP When a pallet is loaded in the BP-direction on the platform of the acceleration bench, the long direction of the pallet is perpendicular to the acceleration direction. When a EUR pallet is placed on the acceleration bench, we get the following view, when looking sideways to the bench: LP When a pallet is loaded in the LP-direction on the platform of the acceleration bench, the long direction of the pallet is parallel with the acceleration direction. When a EUR pallet is placed on the acceleration bench, we get the following view, when looking sideways to the bench: acc dir B (Before) A (After) R (Result) LP [mm] BP [mm] The acceleration where the pallet was exposed to. (typically 0,5g or 0,8g). This value is expressed in 10-1 m/s². The direction of the load on the acceleration bench. This value is LP or BP. The distance between the load and the reference point (the pallet edge or a vertical line coincident with the pallet edge), measured before the test. The measurements are expressed in cm. The distance between the load and the reference point (the pallet edge or a vertical line coincident with the pallet edge), measured after the test. The measurements are expressed in cm. The difference between the B (before) and A (after) measurement, expressed in cm. The dimension of the load in the LP-direction The dimension of the load in the BP-direction

Measuring protocol of containment force. This measuring method is only applied on pallets with stretch film. A metal disk with a diameter of 15 cm is inserted between the load and the stretch film at the following positions: 20cm Top Mid Bottom BP 20cm LP Pull the disk 10cm away from the pallet surface. Use a hand balance with a measuring range of 50kg, to measure the force necessary to obtain a displacement of 10cm. Keep your hand steady for at least 4 seconds and read the measurement.

Measuring the deformation of the pallet. To measure the deformation of the pallet, measurements are taken at three different points before and after the test. The difference between those measurements is used to judge if the pallet behaves stable are not. If the load is inferior to the pallet edges, the value is marked as x. A positive value is used for an outboard conditions. The measurements are taken at the following points: Position 2 Position 3 Position 1 Judgment of the stability. A pallet is considered as stable by ESTL if: The pallet and its load form a unity. During the movement the pallet has to follow the motion of the load. If the plastic deformation (the R values) of the pallet after the test is limited to approx. 4% of the height. The integrity of the transport packaging is maintained. A pallet can be considered as stable if the check mark next to The pallet behaves stable, on the first page of the report is checked or if a certificate has been made. To have a stable pallet, the pallet needs to be stable in both directions.