Installation and User Manual GENEREX RCCMD AS400-Client

Similar documents
Installation and User Manual GENEREX RCCMD AS400-Client

CREATE!FORM SERVER FOR ISERIES V6R1 INSTALLATION

Textura CMS Interface Setup Manual. Version 1.1

Installation of TMKSVR as part of the SAPINST environment

Digital Certificate Manager Setup

Users Guide. FTP/400 File Transfer API and Remote Command Server Version By RJS Software Systems, Inc.


Installation guideline. ConTool

UPS SNMP Watch User manual

Table of contents Introduction. 11-About it. 12-Prerequisites. 13-Installation

Remote Software Facility

TANDBERG MANAGEMENT SUITE 10.0

LogLogic IBM i5/os Collector Guide

Restoring KeyesMail from a CD or Save File onto your iseries or AS/400

Manual Password Depot Server 8

Installation and Administration Guide

Setting Up Specify to use a Shared Workstation as a Database Server

HP ProLiant ML150 System Monitor User Guide

UPS MONITORING SOFTWARE USER MANUAL

Setting Up the Device and Domain Administration

AXIGEN Mail Server. Quick Installation and Configuration Guide. Product version: 6.1 Document version: 1.0

VTLBackup4i. Backup your IBM i data to remote location automatically. Quick Reference and Tutorial. Version 02.00

RCCMD Multiple Server Shutdown Software

SequeLink Server Installation Instructions for the iseries

You re probably already familiar with using a File Transfer Protocol (FTP)

Setup, Management & Troubleshooting Version V6R1M0

Create a New Account Contents

Installation Instruction STATISTICA Enterprise Server

How to export a spool file from an AS/400 and export to a Windows PC

Backup & Restore Guide

Application Note: FTP Server Setup on computers running Windows-7 For use with 2500P-ACP1

TIBCO MFT Platform Server for IBM i User Guide. Software Release April 2013

Kollaborate Server Installation Guide!! 1. Kollaborate Server! Installation Guide!

BestSync Tutorial. Synchronize with a FTP Server. This tutorial demonstrates how to setup a task to synchronize with a folder in FTP server.

XStream Remote Control: Configuring DCOM Connectivity

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Quick Installation and Setup for WinPower Software

Tera Term Telnet. Introduction

Installation Guide for WebSphere Application Server (WAS) and its Fix Packs on AIX V5.3L

Installation and Administration Guide

GWAVA 5. Migration Guide for Netware GWAVA 4 to Linux GWAVA 5

µtasker Document FTP Client

RCCMD Multiple Server Shutdown Software

S OF T WAR E. DirectClock. Keeping the right time on your iseries and PCs with DirectClock (FunkUhr) User Manual

Software Version: 9.8

STIDistrict Server Replacement

How To Set Up Dataprotect

Technical Support Information

DISASTER STRIKES. Are you ready?

Symantec ESM agent for IBM AS/400

Acronis Backup & Recovery 11.5 Quick Start Guide

EZblue BusinessServer The All - In - One Server For Your Home And Business

+27O.557+! RM Auditor Additions - Web Monitor. Contents

Senomix Timesheets for Mac OS X

ilaw Installation Procedure

DBMoto 7 Setup Guide for IBM DB2 for i Transactional Replications

10 STEPS TO YOUR FIRST QNX PROGRAM. QUICKSTART GUIDE Second Edition

Browser Client 2.0 Admin Guide

Installation Instruction STATISTICA Enterprise Small Business

How To Install And Run Cesview Iii (For New Users)

Using Symantec NetBackup with Symantec Security Information Manager 4.5

How to install Magellan 6

- 1 - SmartStor Cloud Web Admin Manual

Quick Start Guide for VMware and Windows 7

How to output SpoolFlex files directly to your Windows server

Configure your ewon using FTP

Training module 2 Installing VMware View

Install / Users Guide

Moxa Device Manager 2.3 User s Manual

Customer Tips. How to Upgrade, Patch or Clone Xerox Multifunction Devices. for the user. Purpose. Upgrade / Patch / Clone Process Overview

Quick Installation and Setup for WinPower Software

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Q N X S O F T W A R E D E V E L O P M E N T P L A T F O R M v Steps to Developing a QNX Program Quickstart Guide

CONNECTING TO DEPARTMENT OF COMPUTER SCIENCE SERVERS BOTH FROM ON AND OFF CAMPUS USING TUNNELING, PuTTY, AND VNC Client Utilities

Bitrix Site Manager ASP.NET. Installation Guide

F-SECURE MESSAGING SECURITY GATEWAY

Level 2 systemsoperationssuite v4.2

Local Caching Servers (LCS): User Manual

Remote Client Program Web Client... 39

UPS Management Software

Kaseya 2. Installation guide. Version 7.0. English

NS Series Programmable Terminal FTP Function

Question: 1 Which associated object must be restored on the system prior to restoring a logical file?

Setting Up Scan to SMB on TaskALFA series MFP s.

Configuring Virtual Blades

For keyboard and touchscreen BlackBerry devices User manual

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

Web Service for Observer. Installation Manual. Part No Revision A

Changing Your Cameleon Server IP

NETWORK ADMINISTRATION

Print/Scan System (U)

EMC Data Domain Management Center

HowTo. Planning table online

System Operator s Guide. MaddenCo Inc. Revised August Copyright 2003 by MaddenCo, Inc All rights reserved.

Quick Start Guide for Parallels Virtuozzo

GUARD1 PLUS SE Administrator's Manual

Installing LearningBay Enterprise Part 2

System Management. What are my options for deploying System Management on remote computers?

Installation of IEXL

Customer Control Panel Manual

Transcription:

GENEREX, Author Bodo Radtke Page 1 - November 28, 2006 - Rel. 1.07 Installation and User Manual GENEREX RCCMD AS400-Client Contents INSTALLATION AND USER MANUAL... 1 GENEREX RCCMD AS400-CLIENT... 1 CONTENTS... 1 DESCRIPTION... 2 A. GENERAL INFORMATION... 2 B. MODULES... 2 C. STEP-BY-STEP INSTALLATION INSTRUCTIONS... 3

GENEREX, Author Bodo Radtke Page 2 - November 28, 2006 - Rel. 1.07 I. Description A. General Information The RCCMD AS400 client is part of the UPSMAN UPS management system that allows the iseries-as400 to act as a client in an UPSMAN managed network. The UPSMAN management module will run on a number of other operating systems (http://www.generex.de/wwwfiles/dokus/1/supp_os/german/pdf/cdversionen.pdf) or on most of the GENEREX standalone network UPS and facility management devices (www.generex.de). Emergency and routine controlled system shutdowns are executed via the network when an authorized UPSMAN manager sends and RCCMD shutdown command to the AS400 running the RCCMD client. The customer defines the shutdown conditions and authorized UPSMAN managers during the setup of the UPS management system. B. Modules 1. Configuration Configuring the AS400 RCCMD client involves setting up a number of parameters which are stored in configuration files. The following file contains the AS400 RCCMD client configuration. a) Configuration file communication 1 rccmdcfg1 This file should hold the IP address of the AS400 which secures the identification of the AS400. This entry must match the entry posted in the IP address found in the configuration of the AS400 if this is not the case see section I.B.2. This entry must also hold the definition of the port that will be used for this program. The default ports is 6003 and if this is not the case please refer to section I.B.2 Default value formation. b) Configuration file communication 2 rccmdcfg2 This file contains information in the form of IP addresses matching the RCCMD senders, that is to say UPSMAN managers or CS121 which manage your UPS. This defines which UPSMAN managers are allowed to send RCCMD messages to the RCCMD AS400 client. These entries act as a filter key for defining authorized UPSMAN managers and should this entry contain no IP addresses see section I.B.2. Default-value formation *all. c) Configuration file SHUTDOWN shutcmd This file contains a predefined shutdown sequence of commands that is enacted when the AS400 RCCMD client receives a valid RCCMD shutdown command. The initial default shutdown file that is written into the system is

GENEREX, Author Bodo Radtke Page 3 - November 28, 2006 - Rel. 1.07 empty. It is the duty of the administrator to define the operations that are to be executed in this file. This may or may not contain actions that are to precede a shutdown such as executing commands, sending messages and safely terminating other processes. (Important: Please see also subject 7! ) The following management program/on-line dialogues for viewing, input, changing and deleting from data records are available: d) Administrative configuration file Communication 1 e) Administrative configuration file Communication 2 f) Administrative configuration file SHUTDOWN C. Step-by-step installation instructions 1. Save/copy the SAVF file from the data media (Email or CD ROM). Following we describe this way using FTP. PC FTP commands for use with the iseries: 1. Login in to the iseries as (QSECOFR!!!) 2. Make SAVF file in QGPL: CRTSAVF FILE(QGPL/RCCMD) 3. Backup the SAVF file from mail / CD in the root directory of the hard drive (we recommend to use root C:\!!) 4. On the PC - START->EXECUTE and type in "CMD" and hit ENTER to open a commandshell. 5. Go into the directory containing SAVF (CD \) 6. Start FTP by the following command : "FTP <xxx.xxx.xxx.xxx - IP adress of your iseries> 7. Then enter the following. User (xxx.xxx.x.x:(none)): as400user 31 Enter password. Password: ******** 230 as400user logged on. ftp> binary 200 Representation type is binary IMAGE. ftp> quote site namefmt 1 250 Now using naming format "1". ftp> put rccmd.savf /qsys.lib/qgpl.lib/rccmd.savf 200 PORT subcommand request successful. 150 Sending file to member RCCMD in file RCCMD in library QGPL. 250 File transfer completed successfully. ftp: 1567104 bytes sent in 2.43Seconds 643.84Kbytes/sec. ftp> quit C:\exit 8. Please backup the files at your iseries library: (At the CD ROM at Directory "OS400/RCCMD") RSTLIB SAVLIB(RCCMD) DEV(*SAVF) SAVF(QGPL/RCCMD) OPTION(*ALL) MBROPT(*ALL) ALWOBJDIF(*ALL)

GENEREX, Author Bodo Radtke Page 4 - November 28, 2006 - Rel. 1.07 INSTALLATION WIZZARD: Please us for the further installation and configuration process the SETUP tool, coming with this software. All following steps described in this documentation are handled through this tool. Start the Setuptool as follows: call xxx/setupmnu, where xxx is the name of the library in which you have saved RCCMD. We recommend to use the name "RCCMD". You may go through all the installation parts step by step, or you may start the installation as complete installation routine. As completet routine use F10 to get to the next step. Follow the instructions on the screen until you get the messge: 'Installation complete'. Finish.'

GENEREX, Author Bodo Radtke Page 5 - November 28, 2006 - Rel. 1.07 9. make sure that the programm SHUTDWN has the right to execute a shutdown call : CHGOBJOWN OBJ(RCCMD/SHUTDWN) OBJTYPE(*PGM) NEWOWN(QSECOFR) CUROWNAUT(*REVOKE) 2. Enter JOB DESCRIPTION : NOTE: If you have backuped the RCCMD system into any other library than RCCMD (not recommended), you have to change the jobdescription accordingly: CHGJOBD XXX/RCCMD INLLIBL(XXX QGPL QTEMP QUSRSYS) where "XXX" represents the name of the library where you have installed RCCMD. 3. Enter CFGTCP : Selection 1 please note your IP Adress. Here has to be an entry (IP adress) - if this is not the case please check your Networkconfiguration with your Administrator. Mit TCP/IP-Schnittstellen arbeiten System: JCBOCS Auswahl eingeben und Eingabetaste drücken. 1=Hinzufügen 2=Ändern 4=Entfernen 5=Anzeigen 9=Starten 10=Beenden Aus- Internetwahl Adresse Teilnetzmaske Leitungsbeschreibung Leitungsart 127.0.0.1 255.0.0.0 *LOOPBACK *NONE 192.168.2.2 255.255.255.0 JCBLIN *ELAN Ende F3=Verlassen F5=Aktualisieren F6=Liste drucken F11=Schnittstellenstatus anzeigen F12=Abbrechen F17=Anfang F18=Ende

GENEREX, Author Bodo Radtke Page 6 - November 28, 2006 - Rel. 1.07 Selection 10 note the hostname which is linked to your IP adress. Add your noted IP adress (if not already present) and choose a hostname. Mit TCP/IP-Host-Tabelleneinträgen arbeiten System: JCBOCS Auswahl eingeben und Eingabetaste drücken. 1=Hinzufügen 2=Ändern 4=Entfernen 5=Anzeigen 7=Umbenennen Aus- Internetwahl Adresse Host-Name 84.142.141.175 BODO.NET 127.0.0.1 LOOPBACK LOCALHOST 192.168.2.2 JCBOCSSERVER 195.186.18.142 MAIL.BLUEWIN.CH 212.227.15.180 MAIL.BODO AUTH.MAIL.ONLINEHOME.DE Ende F3=Verlassen F5=Aktualisieren F6=Liste drucken F12=Abbrechen F17=Listenanfang bei Selection 12 enter/add (if not already present) the hostname to the Domainname TCP/IP-Domäne ändern (CHGTCPDMN) Auswahl eingeben und Eingabetaste drücken. Host-Name........... 'JCBOCSSERVER' Domänenname.......... 'JCBOCS.NET' Domänensuchliste........ *DFT Suchpriorität für Host-Name.. *LOCAL *REMOTE, *LOCAL, *SAME Domain Name Server: Internet-Adresse....... *NONE Ende F3=Verlassen F4=Bedienerf. F5=Aktualisieren F10=Zusätzl. Parameter F12=Abbrechen F13=Verwendung der Anzeige F24=Weitere Tasten

GENEREX, Author Bodo Radtke Page 7 - November 28, 2006 - Rel. 1.07 If there should be already an entry and your Domainname differs from your hostname, please do not change anything here. 4. Enter ADDLIBLE XXX - where XXX represents the name of the RCCMD library 5. Call the programm RCCMDCFG1 (CALL RCCMDCFG1) Enter, if not already present, your IP adress here. Enter the port number 6003 (default). If you do not not want to use the default port, please change to any other available port and change also the CS121/UPSMAN sender accordingly. Enter here you RCCMD Licensekeycode (see your AS 400 Licensedocument for "RCCMD AS 400 Licensekey")). Finish you setting by pressing F2 and save your settings. Leave the Program with F3. )For deleting your entries use F23.) JCBOCS Kommunikationsdatei Verwalten 27.11.05 RCCMDCFG1 00:05:51 Eigene IP Addresse: 192.168.2.2 Lokale Portnummer : 6.003 Sicherheitscode : 77METRO-PARIS011461 F2=Akzeptiern F3=Verlassen F23=Löschen ATTENTION: If there is no Adress here, so you may add this adress as follows: 1. Enter at CommandLine AS400: UPDDTA RCCMD/RCCMDCFG1 2. Enter your IP 3. Return 4. F3 and Return

GENEREX, Author Bodo Radtke Page 8 - November 28, 2006 - Rel. 1.07 6. (Alternatively 7.) Call the program RCCMDCFG2 (CALL RCCMDCFG2). Enter here one or more remote IP adresses of your RCCMD server (CS121 or UPSMAN). Every Adress which you enter here has the permisson to transmit an RCCMD shutdown signal, other adresses, not listed here will be refused to send shutdown signals. Please check youre Firewall so that those RCCMD senders can use the Port 6003 to transmit their signal. NOTE: If you do not enter any IP adress here, all RCCMD senders in your network are allowed to send an RCCMD shutdown signal! We recommend to use this feature only while testing, at normal operation we recommend to restrict the number of RCCMD senders. JCBOCS Kommunikationsdatei Verwalten 27.11.05 RCCMDCFG2 00:09:13 Ferner IP... : 12.21.12.22 F2=Akzeptiern F3=Verlassen F7=Vorwärts F8=rückwärts F23=Löschen After this please press F2 to save your settings. Leave the program with F3. (Using F23 you can delete youre entries, F7/F8 is to scroll through the page.) 7). (Alternatively 6.) Call the program SHUTCMD (CALL SHUTCMD parm' ') Enter the commands you want to execute when an RCCMD Signal arrives. (your shutdown script). The syntax and commands should be tested before manually so that a simple call of this SHUTCMD has the desired reaction - shutting down your ISeries. The command CALL SHUTCMD parm opens a new screen where you can configure the AS 400 Shutdown Sequence (see page 11, Example to test RCCMD transmission without PWRDWNSYS ). The command CALL SHUTCMD parm can be used without any risk, it does NOT execute any shutdown, it just opens a new configuration screen. Note: If you do not enter anything here, the RCCMD will use per default the command PWRDWNSYS (Power Down System) of your system. If this is the case, please check if the option *cntrld or *immed is active.

GENEREX, Author Bodo Radtke Page 9 - November 28, 2006 - Rel. 1.07 If you want to use any other additional call before the shutdown, please enter as last command PWRDWNSYS *immed - otherwise your System will not do any shutdown! Plesae note that without the *immed parameter the shutdown may take quite long. Tip: You can test your installation without risking a shutdown if you enter here any other comman - without the pwrdwnsys. So the moment you enter any command here which is not pwrdwnsys, you can use this for testing the transmission. Youre CS121 or UPSMAN have in the EVENTS configuration menue "testbutton" to transmit an RCCMD shutdownsignal without making the UPS switch to battery. Picture : UPSMAN Windows Configuration EVENT OVERVIEW Picture: UPSMAN Windows INSERT EVENT RCCMD Shutdown Picture : UPSMAN Windows Configuration RCCMD TEST Button Picture : CS121 EVENTS/ALARMS CONFIGURATION OVERVIEW

GENEREX, Author Bodo Radtke Page 10 - November 28, 2006 - Rel. 1.07 Picture : CS121 EVENTS/ALARMS ADD NEW JOB- SEND RCCMD SHUTDOWN - Test Button If this test is successfull, you can be sure that also a real Shutdown call will also work. In the field "sequence" enter the number of the priority of your commands, eg. 1 for the first command, 2 for the seconds, etc. After you have finished your settings enter F2. Now leave the program with F3. Example to test RCCMD transmission without PWRDWNSYS: Use the following testsequence to check your installation without a real OS 400 shutdown. The test consist of 3 entries: All actions will result in a textmessage to QSECOFR aund QSYSOPR. So to check the successfull transmissions of RCCMD signals, read the logfileentries in the system operator message queue (display message queue SYSOPR). After a successfull test continue with subject 8 (start of RCCMDAS400-Client). Eample ShutDown: JCBOCS Shutdownbefehlsverwaltung 27.11.05 SHUTCMD 00:12:02

GENEREX, Author Bodo Radtke Page 11 - November 28, 2006 - Rel. 1.07 Sequence 1 Befehl SNDMSG MSG('FOLLOWING MESSAGES ARE TESTMESSAGES FROM RCCMDAS400-CLIENT') TOUSR(QSYSOPR) F2=Akzeptiern F3=Verlassen F7=Vorwärts F8=Rückwärts F23=Löschen Press F7, now a new Menue opens: JCBOCS Shutdownbefehlsverwaltung 27.11.05 SHUTCMD 00:12:02 Sequence 2 Befehl CALL SETUPTEST1 F2=Akzeptiern F3=Verlassen F7=Vorwärts F8=Rückwärts F23=Löschen etc.... You may also remove the existing entries or add extra entries to this sequence. Please take care that the sequence numbers do not overwrite existing entries. You are still logged in as QSECORF : Enter : CHGMSGQ *USRPRF *break, after this enter : call shutcmd 1st Command to enter: Sequence: 1 Befehl: SNDMSG 'TestShutDownBefehl received' QSECOFR Accept this by F2 and page forward using F7 for te next entry. Return 2nd Comand to enter:

GENEREX, Author Bodo Radtke Page 12 - November 28, 2006 - Rel. 1.07 Sequence: 2 Befehl: SNDMSG 'TEST-RCCMD has been sended' QSYSOPR Accept this by F2 and page forward using F7 for te next entry - or use F8 to return to your previous menue - or use F23 to delete your entries. More entries: Like before, use F3 to leave the program. Here an example with PWRDWNSYS - ideal for testing if you are not allowed to do a real shutdown test of your AS 400.: call shutcmd 1st Command to enter: Sequence: 1 Befehl: SNDMSG 'ShutDownCommand received : System shuts down in 10 Minutesr' QSECOFR Accept this command by F2, page down using F7 for the next command: 2nd Command to enter: Sequence: 2 Befehl: SNDMSG 'RCCMD has been sended, Batterie close to low level' QSYSOPR Accept this command by F2, page down using F7 for another command or go back with F8. To delete your previous entries use F23. 3rd Command to enter: Sequence: 99 Befehl: PWRDWNSYS *IMMED command by F2, or leave the program with F3 In the menue Sequence you define by the sequence number the priority of the commandprocessing. The smallest number has the highest priority and will be executed first. Eg. if you have the sequences 3, 5,1,7,2, than RCCMD will execute your commands in the sequence 1,2,3,5,7. The above shown examples may differ from your system. Please check if the programmed actions are complete to shutdown your AS 400 system, otherwise add extra commands to this sequence. If you have questions please call our hotline service for AS 400 or send us an email with your questions. Tip: Use one or more CL-Programs for your individual sequence control

GENEREX, Author Bodo Radtke Page 13 - November 28, 2006 - Rel. 1.07 8. Start of the AS/400-RCCMD-Client 1. Manual start of the AS/400-RCCMD-Client The Lib RCCMD has to be in the liblist when you start the job. (enter dsplibl). If not present, enter : addlible RCCMD Enter : SBMJOB CMD(CALL PGM(STARTRCCMD) PARM('RCCMD')) JOB(RCCMD) JOBD(RCCMD/SOCKSERV) USER(*JOBD) SYSLIBL(*SYSVAL) CURLIB(*CRTDFT) INLLIBL(*JOBD) And check this by enter: WRKACTJOB JOB(RCCMD) The should be listed now, if not than there might be an error in your installation. Work with active jobs JCBOCS 28.11.05 00:24:36 CPU %: 0,0 Abgelaufene Zeit: 00:00:00 Aktive Jobs: 163 Auswahl eingeben und Eingabetaste drücken. 2=Ändern 3=Anhalten 4=Beenden 5=Arbeiten mit 6=Freigeben 7=Nachricht anzeigen 8=Mit Spool-Dateien arbeiten 13=Unterbrechen Ausw. Subsystem/Job Benutzer Art CPU % Funktion Status RCCMD BCRADTKE BCH 0,0 PGM-SOCKSERV TIMW Ende Parameter oder Befehl ===> F3=Verlassen F5=Aktualisieren F10=Neubeginn F11=Aufgelaufene Daten F12=Abbrechen F23=Weitere Angaben F24=Weitere Tasten Note. The library RCCMD is the name of the saved library in your As 400. At a restore into any other library, please use this new name accordingly. 2. Automatic programstart at IPL Enter the following command: ADDAJE SBSD(QUSRWRK) JOB(RCCMD) JOBD(RCCMD/SOCKSERV) ** This commands makes RCCMD to start automatically at every System reboot ** At the next Systemstart : please check the autostart entry by entering: WRKACTJOB JOB(RCCMD), the job should be listet now, if not than the installation is incorrect.

GENEREX, Author Bodo Radtke Page 14 - November 28, 2006 - Rel. 1.07 The rccmd-comand is always inside the saved library RCCMD. By entering the librarylist in the jobdescription (see subject 2) you do not need any entry in other jobs or menues. (not needed in systemvalue QUSRLIBL, no need to change manually by "addlibl" or "chglibl"). This is only needed during the installation and the manual start of RCCMD, not at the automatic start) You may also use a differen way to autostart RCCMD: Autostart via subsystem in QSTRUP (SystemstartProgramm from IBM): You may also use the IBM scheduler to start RCCMD. Check if the Objekt library is present in the Liblist. A helpfunction is available for the parameter USER in the command smbjob and/or chgjobd. ** This product is compatible with OS/400-Releases V4R5M0 through V5R3M0 **