LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

Similar documents
Application Note. An introduction to using the Touchpoint Pro PC Configuration Software

Touchpoint Pro. Flexible Gas Control System

Industrial Strength Leak Detection

WD-AMX Water Detection Controllers

API Marine. BMS Presentation. Ballast Measurement Systems

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

N4385A / N4386A Distributed Temperature System (DTS)

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Regards from the Team at Rheology Solutions.

STAR PIPE Polska S.A ul. Gdyńska Czerwonak tel fax

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

TMS TANK MANAGEMENT SYSTEM

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Inductive Proximity Sensors

Stove Guard Kit User Manual

AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM

Liquid Leakage Sensor Amplifier

Duct Humidity Transmitter

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

Quick Connect. quick - simple - efficient.

Manual for Fire Suppression & Methane Detection System

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Honeywell Analytics Lines of Business

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

Temperature & Humidity SMS Alert Controller

ALARMLINE ANALOGUE Linear Heat Detection System

site monitoring Kit Site Monitoring Kit User Manual we prove it.

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

FAAST. Fire Alarm Aspiration Sensing Technology

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

S-series Mass Connection Solutions

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

The Ambient Air Monitoring System

SMART SENSOR COLLECTION

+ A B V B NO NC V COM PV PV

Process Alarm Solutions

HCE80/HCC80/HCE80R/HCC80R

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Dew-Point Measurement Solutions

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Electronic Control Devices The European Product Catalogue 2007

T7079A,B Solid State Remote Temperature Controllers

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Combi B Alarm box. Mounting instructions

Phase Modular Finally the benefits of Modular ups are for all

Power & Environmental Monitoring

GSM Voice Auto Dialer & SMS Sender JC-999

SC100 Series Seismic Vibration Sensors. The Best Way to Protect High-Risk Commercial Assets

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Energy Management Solutions

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

AXIS PS12 Outdoor Power Supply. Installation Guide

Operating Instructions

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Optical fiber intrusion detection fence sensor

How To Use An Irius Pid Detector

Inductive sensor NI10-M18-Y1X-H1141

How To Use A Ds340 (Dsp)

and in environments up to 80º F (27º C). Introducing Millivision s Next-Generation Low Cost Passive Millimeter X350 Scanning System.

Electronic Control Devices The European Product Catalogue 2007

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

*.ppt 11/2/ :48 PM 1

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

ENAiKOON ultrasonic fuel-level sensor

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Battery Powered Thermal Mass Flow Meters for Gases

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Ground Resistance Clamp On Tester

DUCT SMOKE DETECTOR D4120

Y7230A CO 2 Alarm System

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

User's Guide. True RMS Industrial Multimeter

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

T0118 T2118 T3118. Instruction Manual

EGSTON Standard E2xFxWx 12W

Arc Terminator Active Arc-Resistant Switchgear

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Fire & Security DETECTORS

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

Cisco Nexus 7000 Series Power Supply Modules

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

T5000 T000 LCD Digital Fan Coil Thermostat

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Transcription:

LeakFilm Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

LeakFilm The most reliable, durable, cost-effective solution Unlike some other forms of liquid leak detection, LeakFilm stands up to the challenges of your facility: Durable and flexible. You can walk on it, roll carts over it, wrap it around pipes, and subject it to varying levels of temperature, humidity and dust with no false alarms. Fast response. When LeakFilm senses a liquid leak, the LeakFilm controller immediately notifies you so you can address the situation without delay. Additionally, certain LeakFilm configurations can measure the distance from the leak point to the controller giving you increased visibility to the location of the leak. Long life. Unlike sensing cables, which may need to be replaced after exposure to some liquids, LeakFilm withstands water and conductive liquids*. In the event of exposure, just wipe off the ribbon and reuse it no replacement costs. Easy to install and maintain. Use the adhesive backing and supplied connectors to install LeakFilm wherever you need it. And if it tears, simply cut and reconnect the film no need to replace the whole section. You can even write on the ribbon if needed. *NOTE: Conductive and Conductive_D are reusable. Chemical and hydrocarbon LeakFilm detection must be replaced at the spot of the leak after contact. What happens if a leak causes liquid to come into contact with the sensitive equipment in your semiconductor facility? Would you know about it? Would you have time to correct the problem, preventing damage and costly downtime? LeakFilm uses innovative technology to alert you to leaks of water, chemicals and hydrocarbons so you can take immediate action to protect your assets, manage costs and ensure constant uptime. In addition to protecting your equipment, LeakFilm helps you protect your people by monitoring for liquid leaks that cause life-safety hazards such as slips, falls and inhalation of dangerous vapors. Flexible applications for liquid leak detection LeakFilm is a liquid leak detection system that combines unique liquid-sensing film which can be networked into broader building alarm systems. When liquid comes into contact with the LeakFilm, your controller will alarm within a few seconds, allowing you address the situation without delay. LeakFilm sensors can detect water, conductive liquids, strong acids, and hydrocarbons. The sensor can easily be installed with the adhesive tape backing, and in the event a sensor needs to be replaced LeakFilm can be easily spliced using the available connectors allowing easy and cost efficient replacement of LeakFilm sensors. Thanks to its flexible form and adhesive backing, our patented LeakFilm is easy to install in numerous applications on floors, walls, pipes, equipment and other areas that could be susceptible to leaks of hazardous chemicals. Use LeakFilm to monitor for liquid leaks around: Wet benches Photolithography equipment Chemical storage rooms Gas cabinets Boilers Distribution boxes And if your facility has a computer room or communications room, use LeakFilm to monitor for one of the biggest threats water. Leaks can come from such sources as air conditioning systems, concealed piping and plumbing in adjacent rooms.

LeakFilm System Components LeakFilm Sensor LeakFilm Conductive Water and conductive liquids leak detection film sensor LeakFilm Conductive_D Water and conductive liquids leak detection film sensor with leak location detection Strong acid liquids leak detection film sensor with leak location detection LeakFilm Hydrocarbon Hydrocarbon liquids leak detection film sensor LeakFilm Controller LeakFilm Mini One channel mini conductive liquid leak detection controller with broken sensor detection LeakFilm 5 Five channels conductive liquid leak detection controller with broken sensor detection LeakFilm Pro One channel conductive and chemical liquid leak detection controller with leak location detection LeakFilm HC One channel hydrocarbon liquid leak detection controller with broken sensor detection LeakFilm MC Master liquid leak detection controller LeakFilm Connector Connects controller and sensor Connect the sensor and sensor Connect the sensor and sensor End Connector 4 Lines End connector to LeakFilm Conductive_D, LeakFilm Chemical and LeakFilm Hydrocarbon film sensor End Connector 2 Lines End connector to LeakFilm Conductive film sensor LeakFilm System How LeakFilm Works LeakFilm is a one-inch wide ribbon with tiny holes on top and a conductive solution inside. When liquid passes through the holes and touches the circuit film s wires, a change in the electrical resistivity will be detected by the LeakFilm controller s algorithm, and will signal a leak detection so you can protect your assets and prevent downtime. The perfect complement to your toxic gas monitoring system Monitoring for liquid leaks is another important way to prevent costly downtime and ensure life safety, and LeakFilm delivers the best combination of accuracy, flexibility and ease of use.

LeakFilm Specifications Specifications - Sensor Product Name LeakFilm Conductive LeakFilm Conductive_D LeakFilm Hydrocarbon Target Water and conductive liquid Water and conductive liquid Sulfuric acid, Hydrofluoric acid, Nitric acid Liquid organic solvent Material PET PET PET PET Circuit Thickness 5 to 10 μm 5 to 10 μm 5 to 10 μm 5 to 10 μm Film Thickness Connector Material PBT PBT PBT PBT Storage Temperature -10 to 80 C -10 to 80 C -10 to 80 C -10 to 60 C Operating Temperature -10 to 55 C -10 to 55 C -10 to 55 C -10 to 55 C Operating Humidity 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH Weight Under 20 g/m Under 20 g/m Under 20 g/m Under 20 g/m Response Time for Leakage* Under 4 sec Under 4 sec Under 10 sec Toluene: under 1min Benzene: under 1min Gasoline: under 1min Diesel: under 5min Kerosene: under 5min Chloroform: under 1min Response Time for Open Under 4 sec Under 10 sec Under 10 sec Under 17sec Leak Location Accuracy N/A ±1 m (above 10 m) ±1 m (above 10 m) N/A Length 0.5 m to 50 m 3 m to 200 m 3 m to 200 m 0.5 m to 50 m Specifications - Controller Product Name LeakFilm Mini LeakFilm 5 LeakFilm Pro LeakFilm HC LeakFilm MC Applicable Sensor LeakFilm Conductive LeakFilm Conductive LeakFilm Conductive_D LeakFilm Hydrocarbon N/A Applicable Controller N/A N/A N/A N/A LeakFilm Pro, LeakFilm 5, LeakFilm HC Display N/A N/A 8 X 2 Character LCD / LED back light 8 X 2 Character LCD / LED back light 20 X 4 Character LCD / LED back light Power 20 to 36 VDC 20 to 36 VDC 20 to 36 VDC 20 to 36 VDC 100 to 240VAC 50/60 Hz Power Consumption Max 1 Watt Max 4 Watt Max 4 Watt Max 4 Watt Max 10 Watt LED Indication Sound Level Over 80dB @ 10 cm Over 80dB @ 10 cm Over 80dB @ 10 cm Over 80dB @ 10 cm Over 80dB @ 10 cm Output Relay (NO) 30 VDC 5A, or 250VAC 5A Relay (NO) 30 VDC 5A, or 250VAC 5A * Typical response time at 20 C(68 F). ** To use the digital communication, please contact a Honeywell Analytics Representative for further details. Relay (NC, NO) 24VDC 2A or 120 VAC 1A (Max. Switching voltage 60VDC or 240VAC) Relay (NC, NO) 24VDC 2A or 120 VAC 1A (Max. Switching voltage 60VDC or 240VAC) Relay (NC, NO) 24VDC 2A or 120 VAC 1A (Max. Switching voltage 60VDC or 240VAC) LEAK Relay (NC, NO) BROKEN Relay (NC, NO) Com Err Relay (NC, NO) Communication N/A RS485 (**Modbus ) RS485 (**Modbus ) RS485 (**Modbus ) RS485 (**Modbus ) Communication Function N/A (Status Transmission) Leak Location Data Recording N/A N/A 9 event - year / month / day / hour / min / Leak location 9 event - year / month / day / hour / min / Leak or Broken message Leak Location Communication Error and Clearance 999 event - Detector ID / Leak and Leak location or Broken or Communication error/ year - month - day hour : min : sec / Storage Temperature -10 to 65 C -10 to 65 C -10 to 65 C -10 to 65 C -10 to 65 C Operating Temperature -10 to 55 C -10 to 55 C -10 to 55 C -10 to 55 C -10 to 55 C Operating Humidity 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH Leak Location Accuracy N/A N/A ±1 m (above 10 meter) N/A N/A ID Setting N/A 1 to 15 1 to 200 1 to 200 1 to 32 IP Rating IP20 IP20 IP20 IP20 IP43 EMC Directive 2004/108/EC EN61000-6-4/A1:2011, EN61000-6-2:2005, EN61000-3-2/A2:2009, EN61000-3-3:2008 Electrical Safety 1) Low Voltage Directive 2006/95/EC:EN 61010-1:2010 2) US:UL 61010-1 3rd Edition 3) Canada: CAN/CSA-C22.2 No.61010-1 3rd Edition

Order Information and Configuration Rules Order Information 1. LeakFilm Controller Part Number Product Name Description HLFC1MNN LeakFilm Mini 1 Channel Mini Conductive Controller with Broken Sensor Detection HLFC5CRN LeakFilm 5 5 Channel Conductive Controller with Broken Sensor Detection HLFC1HRN LeakFilm HC 1 Channel Hydrocarbon Controller with Broken Sensor Detection HLFC1DRD LeakFilm Pro 1 Channel Conductive & Chemical Controller with Leak Location Detection HLFCMSRD LeakFilm MC Master Controller with RS485 2. LeakFilm Sensor Part Number Product Name Description HLFSSCNN-100 HLFSSCNN-050 HLFSSCNN-001 HLFSSCND-100 HLFSSCND-050 HLFSSCND-001 HLFSSAND-100 HLFSSAND-050 HLFSSAND-001 HLFSSHNN-100 HLFSSHNN-050 HLFSSHNN-020 HLFSSHNN-001 LeakFilm Conductive LeakFilm Conductive_D LeakFilm Hydrocarbon 100 m Conductive Sensor 50 m Conductive Sensor Custom Length Conductive Sensor (per meter) 100 m Conductive Sensor with Leak Location Detection 50 m Conductive Sensor with Leak Location Detection Custom Length Conductive Sensor with Leak Location Detection (per meter) 100 m Chemical Sensor with Leak Location Detection 50 m Chemical Sensor with Leak Location Detection Custom Length Chemical Sensor with Leak Location Detection (per meter) 100 m Hydrocarbon Sensor 50 m Hydrocarbon Sensor 20 m Hydrocarbon Sensor Custom Length Hydrocarbon Sensor (per meter) 3. LeakFilm Connector Part Number Product Name Description HLFNCSND-005 with 5 meters Lead Wire HLFNCJND-000 with 15 cm Lead Wire HLFNCJND-001 with 1 meter Lead Wire HLFNCLND-000 HLFNCEND-000 End Connector 4 Lines End Connector 4 Lines with Leak Location Detection HLFNCENN-000 End Connector 2 Lines End Connector 2 Lines Configuration Rules Master Controller LeakFilm MC Leak Film MC Leak Film MC Controller LeakFilm Pro LeakFilm HC LeakFilm 5 LeakFilm Mini Sensor LeakFilm Conductive_D LeakFilm Hydrocarbon LeakFilm Conductive LeakFilm Conductive End Connector End Connector 4 Lines End Connector 4 Lines End Connector 2 Lines End Connector 2 Lines Other Connectors

Honeywell Gas Detection Honeywell is able to provide gas detection solutions to meet the requirements of all applications and industries. Contact Honeywell in the following ways. Fixed and Portable Gas Detection Korea #701 Kolon Science Valley (1) 43 Digital-Ro 34-Gil, Guro-Gu Seoul 152-729 Korea Tel: +82 (0)2 6909 0300 Fax: +82 (0)2 2025 0329 Analytics.ap@honeywell.com Singapore Level 1, Honeywell Building, 17 Changi Business Park Central 1 Singapore 486073 Tel: +65-65803776 Fax: +65-65803663 Australia Unit 1B, 69 Dalton Road Thomastown, Victoria 3074 Tel: +61-3-94642770 Fax: +61-3-94642772 Japan New Pier Takeshiba South Tower 20F 1-6-1 Kaigan Minato-ku Tokyo 105-0022 Japan +81-3-6730-7320 +81-3-6730-7224 India Sec-36, Pace City-II, Gurgaon Haryana-122004, India Tel: +91-124 4752700 Fax: +91-124 4752750 honeywellanalytics.india@honeywell.com Technical Services AP: ha.ap.service@honeywell.com EMEAI: HAexpert@honeywell.com US: ha.us.service@honeywell.com www.honeywellanalytics.com www.raesystems.com Honeywell Analytics Experts in Gas Detection Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. 12892_H_Touchpoint 13390_H_LeakFilm_DS01146_V2_AP Pro_DS01107_V1_EN-AP 03/15 04/15 2015 Honeywell Analytics 2015 Honeywell Analytics