APE T CFRP Aslan 500

Similar documents
Strengthening of a Bridge Using Two FRP Technologies. Paolo Casadei, Nestore Galati, Renato Parretti and Antonio Nanni

Technical Notes 3B - Brick Masonry Section Properties May 1993

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

In-situ Load Testing to Evaluate New Repair Techniques

The Original Carbon Fiber Reinforced Polymer System

Fiberglass Rebar (GFRP Rebar)

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

USE OF CFRP LAMINATES FOR STRENGTHENING OF REINFORCED CONCRETE CORBELS

STRENGTHENING AND LOAD TESTING OF THREE BRIDGES IN BOONE COUNTY, MO

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

BEHAVIOR OF SHORT CONCRETE COLUMNS REINFORCED BY CFRP BARS AND SUBJECTED TO ECCENTRIC LOAD

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Numerical modelling of shear connection between concrete slab and sheeting deck

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

MATERIALS AND MECHANICS OF BENDING

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

Shear Strengthening. Sika CarboDur Composite Systems

Section 5A: Guide to Designing with AAC

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...

CFRP STRENGTHENING OF CIRCULAR CONCRETE SLAB WITH AND WITHOUT OPENINGS

CA-48 TECHNICAL SPECIFICATION

Chapter 8. Flexural Analysis of T-Beams

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Detailing of Reinforcment in Concrete Structures

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

PC-Concrete Injectable Concrete Anchoring and Repair System

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

Dowel-Bar Retrofit Using Polyester Polymer Concrete

Bridge Structural Rehabilitation Using FRP Laminates

ABSTRACT 1. INTRODUCTION 2. DESCRIPTION OF THE SEGMENTAL BEAM

Overview of Topics. Stress-Strain Behavior in Concrete. Elastic Behavior. Non-Linear Inelastic Behavior. Stress Distribution.

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

SECTION 3 DESIGN OF POST- TENSIONED COMPONENTS FOR FLEXURE

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Solid Mechanics. Stress. What you ll learn: Motivation

INTRODUCTION TO BEAMS

Series 4000 Fiberglass Pipe and Fittings

Hardened Concrete. Lecture No. 14

A Decade of Performance of FRP-Repaired Concrete Structures

Seismic Retrofit of Reinforced Concrete Beam- Column T-Joints in Bridge Piers with FRP Composite Jackets

Reinforced Concrete Design

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR FLEXURE

Green Thread Product Data

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.

Strengthening and Repair of Reinforced Concrete Structures. Ian Wienholt Business Development Manager

Condition assessment and repair of antenna towers concrete foundations

CARBON/DYNEEMA INTRALAMINAR HYBRIDS: NEW STRATEGY TO INCREASE IMPACT RESISTANCE OR DECREASE MASS OF CARBON FIBER COMPOSITES

Structural Integrity Analysis

Bonding Agents: The Good, the Bad, and What Works. Bond with Your Concrete

Design, Construction, and Field-Testing of an RC Box Culvert Bridge Reinforced with GFRP Bars

SEISMIC RETROFITTING OF EARTHQUAKE-DAMAGED CONCRETE COLUMNS BY LATERAL PRE-TENSIONING OF FRP BELTS. K. Nasrollahzadeh Nesheli 1 and K.

DETERMINATION OF TIME-TEMPERATURE SHIFT FACTOR FOR LONG-TERM LIFE PREDICTION OF POLYMER COMPOSITES

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing

Repair of Fatigued Steel Bridge Girders with Carbon Fiber Strips

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

bi directional loading). Prototype ten story

Structural Retrofitting Process and Techniques

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

September 1, 2003 CONCRETE MANUAL CONCRETE PAVEMENT REHABILITATION

Reinforced Concrete Slab Design Using the Empirical Method

FLEXURAL BEHAVIOUR OF HYBRID FRP-UHPC GIRDERS UNDER STATIC LOADING

Phosphoric Acid Anodized Aluminum Honeycomb

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Basics of Reinforced Concrete Design

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Embedded Parts Introduction - Anchors

The Strength of Concrete

Solution for Homework #1

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Chapter - 3 Design of Rectangular Beams and One-way Slabs

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Tyfo Fibrwrap Blast Panels. Prefabricated Blast Wall System

Prestressed Concrete Pipe Fitness for Service and Repair

Activity 2.3b Engineering Problem Solving Answer Key

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Stress Strain Relationships

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading

Incorporating Innovative Materials for Seismic Resilient Bridge Columns

PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Glass Fibers Reinforced Composits (GFRP) for TUNNELLING

Transcription:

Carbon Fiber Reinforced Polymer (CFRP) Tape is used for structural strengthening of concrete, masonry or timber elements using the technique known as Near Surface Mount or NSM strengthening. Use of CFRP Tape in the NSM technique is licensed under US Patent #5,894,003. Benefits of CFRP Tape The Benefits of using CFRP Tape for structural strengthening using the Near Surface Mounted technique include: Better bond with the substrate compared with externally bonded FRP systems, means greater utilization of the FRP. CFRP Tape arrives with guaranteed physical & mechanical properties. Surface preparation issues are minimized. After installation, NSM tape is protected from mechanical damage and offers better fire performance than externally bonded systems. Strengthening results are superior to externally bonded systems. Installation of NSM CFRP Tape is faster and can be done in more diverse weather conditions. can be used to remove posted limits on bridges. Features of CFRP Tape is a 2mm X 16mm tape designed specifically for NSM strengthening. It is made from 700ksi, 33Msi carbon fiber, 60% by volume in a Bisphenol Epoxy Vinyl ester resin matrix. A surface treatment is applied to the wide faces of the CFRP Tape to enhance the bond characteristics when used with structural epoxy adhesives or cementitious latex modified grouts. The nominal diameter or cross sectional area of is the same as a #2 or 1/4 diameter rod. is dispensed in 250ft lengths similar to a tape measure. It is furnished in continuous lengths in spools that are 250ft (76m) long.

Physical Properties Cross Sectional Tensile Tensile Modulus of Ultimate Designation Width Thickness Area Strength* of Elasticity Strain mm # mm in mm in mm 2 in 2 MPa ksi Gpa psi10 6 % 6 mm #2 16 0.63 2.079 31.2 0.49 2068 300 124 18 0.017 10 mm #3 16 0.63 4.5.177 71.3.1104 1965 285 124 18 0.015 Hughes Brothers reserves the right to make improvements in the product and/or process which may result in benefits or changes to some physical-mechanical characteristics. Please refer to our web site at www.hughesbros.com for the most current values. The data contained herein is considered representative of current production and is believed to be reliable and to represent the best available characterization of the product as of December 2002. Tensile strengths shown are the average minus three standard deviations. Per ACI440, this value is f* fu, the guaranteed tensile strength. Tensile Modulus of Elasticity values are the average of a population of test specimens as per ACI440 guidelines. CFRP tape being tested Valid Failure Coefficient of Thermal Expansion: Transverse Direction... Longitudinal Direction... 41 to 58 X 10-6 /F (74 to 104 X 10-6 /C) 4 to 0.0 X 10-6 /F (-9 to 0.0 X 10-6 /C) Barcol Hardness: 48-55 per ASTM D2583

Unlike steel materials, the stress-strain curve of FRP materials is linear elastic to failure. NSM Design Structural strengthening using is based on the principles of ACI440.2R-02 Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures and ACI440.1R-01 Guide for the Design and Construction of Concrete Reinforced with FRP Bars. As of this writing, ACI committee 440 has not yet addressed the new and novel techniques described by researchers involved in NSM strengthening. A companion document to this product literature, Guide to Flexural and Shear Strengthening of RC members using Near Surface Mounted FRP Composites describes proposals under consideration but not yet adopted by committee 440. (Oct 2002). In addition to the proposed design guideline, design software is available at no charge that implements the design philosophy described in the companion document for both CFRP Tape and Aslan 200 CFRP bars. The program requires the user to provide geometry, material properties and loading configurations. The ultimate flexural strength and shear strength are evaluated by separate software routines. The software was developed by CoForce International Consultants. The software modules are based in MathCad. The programs are intended for use only by structural and analysis professionals and do not, nor are intend to, replace formal training with respect to the design, construction, repair or strengthening of concrete structures. While every attempt has been made to verify and validate the accuracy and contents of this program, no guarantee or warranty either expressed or implied, is offered regarding the universal adoption of the results of the program. It is the responsibility of the structural design and analysis professionals to substantiate their conclusions drawn from the results of the program. The authors and Hughes Brothers, Inc will not be held responsible for the conclusions, interpretations, recommendations or analyses of others using this program. Design guidelines published in the companion document are adapted from a paper to be published in the Journal of Structural Engineering, ASCE by Parretti and Nanni. The role of Hughes Brothers is simply as manufacturer of the materials used in these techniques and to assist the practitioner in the adoption and use of the materials produced.

NSM Design Example BASEMENT WALL STRENGTHENING The following example shows the strengthening of a basement wall subjected to a maxium of 305 lbs per square foot of earth pressure. In this instance, since the earth force will be sustained against the basement wall, the use of CFRP Tape is desirable. Objective The design specifications are in compliance with ACI 440.1R-01, hereafter referred to as ACI 440 and ACI 530-02/ASCE 5-02/TMS 402-02, hereafter referred to as ACI 530 reported by the Masonry Standard Joint Committee, and Masonry Designerʼs Guide (MDG) Materials Table 1 presents the properties of concrete masonry, and carbon (CFRP) tapes. Table 1 Engineering Properties of Concrete Masonry and FRP Reinforcement Material Masonry Guaranteed Guaranteed Compressive Strength Tensile Strength Modulus of Elasticity f ' m [psi] f* fu [ksi] E f [ksi] Masonry 2,000 - - CFRP Tape - 300 20,000 Design Considerations The design of the strengthening follows Allowable Stress Design (ASD). Thus, according to ACI 530 and MDG, the following parameters were computed for the masonry: f b = 1 3 f 1 m = 0.7 ksi f v = f 'm = 44.7 psi (1) E m = 900 f 'm = 1800 ksi where F b, F v and E m represent allowable compressive strength, shear strength and modulus of elasticity of the masonry, respectively. The design properties used for the FRP reinforcement are expressed as follow: F fu = C E f* fu F f_all = k f fu (2) December 2002 Hughes Brothers, Inc. 210 N. 13 th Street Seward, NE 68434 Phone: 800-869-0359 402-643-2991 Fax: 402-643-2149 www.hughesbros.com Email: doug@hughesbros.com 5

where f fu and f f-all are the ultimate design strength and allowable design strength of FRP reinforcement, CE is the environmental reduction factor as reported in ACI 440 (Table 7.1), and k gives the percentage of the ultimate to define the allowable stress of the FRP reinforcement. A value of k equal to 0.3 is used in the case of the CFRP tape in order to avoid premature modes of failure. Design modulus of elasticity of FRP is taken as indicated by the Hughes Brothers. Table 2 summarizes the assumed design properties for FRP. Table 2 Design Properties of the FRP Reinforcement Material C E K f fu (ksi) f f-all (ksi) CFRP Tape 0.9 0.3 270 81 External Loads The pressure exerted to the wall by the earth is considered to have a triangular distribution, with the maximum pressure w=305 psf at the bottom of the wall. Analysis The structural analysis is carried out considering that the wall is simply supported (see Fig 1). Figure 1 Simply Supported Beam Used in the Design. Maximum bending moment is expressed as (Eq. (3)): M 1 = wl 2 9 3 (3) Maximum shear force due to the applied load is expressed as (Eq.(4)): V 2 = wl 3 (4) The amount of FRP needed to satisfy the load demand is one CFRP Tape every 24 in. This spacing of 24 in. does not exceed the maximum spacing recommended by MDG (four times the wall thickness). 6

Table 3 Design of FRP Reinforcement. Description (1 CFRP Tape@24 ) Sec. 1 Sec. 2 Width of the wall, b [in] 12 12 Thickness of the wall, h [in] 10 10 FRP Maximum Tensile Stress, f f [ksi] 64.83 - Max. Masonry Compressive Stress, f b [ksi] 0.421 - Max. Masonry Shear Stress, f v [psi] - 7.592(*) *) Calculated with the maximum shear force (Eq. (2-19), ACI 530) A sketch of the reinforcement placed into the masonry blocks is depicted: Figure 2 - CFRP Reinforcement Location Detail. Installation After assessment of the condition of the existing structure and design by a competent professional, installation of the CFRP Tape is performed according to the following general outline. 1. Using a diamond blade concrete saw or grinder, a groove of 1/4 X 7/8 is cut. The use of two diamond blades on the arbor may be necessary to make the 1/4 width cut. 2. The groove is thoroughly cleaned using a vacuum and/or compressed air. 3. The slot is masked to prevent excess adhesive from marring surface. 4. Structural adhesive Gel is filled in the slot. Care should be made to avoid entrapped air voids. 5. The CFRP Tape is seated on edge in the groove. 6. General clean up and removal of any masking. Recommended Structural Adhesives include: Master Builders Concresive 1420 Saw Kerf is cut into element. Filling groove with structural adhesive. (Installation photos courtesy of Univ of Missouri Rolla) December 2002 Hughes Brothers, Inc. 210 N. 13 th Street Seward, NE 68434 Phone: 800-869-0359 402-643-2991 Fax: 402-643-2149 www.hughesbros.com Email: doug@hughesbros.com 7

Installation (con't.) Inserting CFRP Tape on edge. Strengthened installation with clean appearance. Strengthening Applications suitable for structural strengthening using CFRP Tape include: Increasing flexural capacity of beams Shear Strengthening of beams Flexural Strengthening of slabs Strengthening of Concrete, Masonry or Timber During the summer of 2002, the Martin Spring Bridge near Rolla Missouri was strengthened using CFRP Tape. Load testing of the bridge verified the effectiveness of the NSM methods and bridge posting limits were removed. (upper right) Concrete beam without shear stirrups, designed to fail in shear was strengthened with as part of undergraduate reinforced concrete design coursework. The resulting failure mode after strengthening was yielding of the longitudinal reinforcing steel. (right) 8 2002 Hughes Brothers, Inc. 210 North 13th Street Seward, Nebraska 68434 Phone 800.869.0359 or 402.643.2991 / Fax 402.643.2149 www.hughesbros.com