Commercial Coil Cleaning:



Similar documents
1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

Terms of Reference Air Handling Unit (HVAC System) Cleaning

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Introducing an All New Line of Cleaning Chemicals

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

Innovent LASER Packaged Fresh Air Conditioning Units

Air Conditioner Maintenance

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Water Incursion Standard Operating Procedure

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

IEQ-15 Air Distribution System

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Basics of HVAC Cleaning

WATER DAMAGE/MOLD INVESTIGATION. Massachusetts Department of Developmental Services 68 North Main Street Carver, Massachusetts

HVAC Design Requirements

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Energy Efficiency. Energy Efficient Home Cooling:

By Tom Brooke PE, CEM

Mechanical Systems Proposal revised

HVAC Schedule. Contract # GS-07F-9452S Contract # GS-06F-0091S 2008 NCH CORPORATION 2009 NCH CORPORATION

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Your Guide to Buying an Energy-Efficient Central Air Conditioner

UI Procedures for Asbestos Management

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Containment Challenges & Engineering Solutions for Low Containment. National Centers for Animal Health Ames, Iowa Dennis Jones, Facility Engineer

NYU Safety Policy Manual

NIOSH Interim Recommendations for the Cleaning and Remediation of Flood-Contaminated HVAC Systems: A Guide for Building Owners and Managers

Data Center and Computer Room Services Specialty Services Data Center and Computer Room Products Sub-Floor Cleaning

Specifications for Removal and Replacement of Water Damaged/Mold Impacted Materials

ORIENTAL COCKROACH PREVENTION & CONTROL

Corrosivity of Water Supplies

Dehumidification Frequently Asked Questions

NORMI Professional Guidance for DIY Projects

HVAC Checklist - Long Form

EACO DOP / PAO TESTING GUIDELINE 2013

NADCA White Paper: Restoring Energy Efficiency Through HVAC Air Distribution System Cleaning

Quick wins for energy savings in buildings

Glossary of Heating, Ventilation and Air Conditioning Terms

Evaporative Cooling System for Aquacultural Production 1

The Importance of Clean Coils In Commercial Equipment

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM

ASBESTOS MANAGEMENT PROGRAM

ENHANCED LABORATORY HVAC SYSTEM

Daimer s All-About Guide to Carpet Cleaners

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Specifications For Rehabilitation Hudson #1A Hudson #2 Foster Island Well #41

SUCCESS STORY ENERGY TO CARE UF HEALTH SHANDS VISTA REHAB & UF HEALTH SHANDS CANCER HOSPITAL (SOUTH TOWER)

Enclosed Football Stadium Design History and Lessons Learned

WATER DAMAGE INVESTIGATION. Massachusetts Gaming Commission 101 Federal Street Boston, Massachusetts

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

Radford University. Indoor Air Quality Management Plan

SECTION 810 SEWER LINE CLEANING

ASBESTOS SCIENCE TECHNOLOGIES, INC.

Why is my air conditioner dripping on my customers?

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:

Remediation of Mold Contaminated Ductwork

CLEANING MANUAL. Warranty updated on 4/21/11. Supersedes all previous versions. Check website for updates.

CARPET CARE PROGRAM. Dustbane Products Limited

HUMIDIFICATION SYSTEMS: A COST AND EFFICIENCY COMPARISON

How To Calculate Cost Of An Eco-Friendly Building

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Trane s Position on UV-C Lights

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Printing and Publishing Energy Savings Guide

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

CLEANING AND SANITIZING

AIR CONDITIONING MAINTENANCE

Coil Cleaning Program

Electrical Classification

Mold Management Plan Operations & Maintenance

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Element D Services Plumbing

White rust on galvanized and galvanized pre-painted steel. Technical Information

Guidelines for Mold Remediation (Removal)

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Optimizing Tank Cleaning Operations

Construction Drawings and Terminology for the Infection Prevention Professional. Objectives. Disclaimer

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

Water Storage Tanks. (Cisterns) Drinking water and your health. Water Hauling. Rainwater Collection. Construction Material

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High

Automobile Air Conditioning Primer

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Transcription:

18 Commercial Coil Cleaning:

by Barry Harris, PH.D., ASCS 1, Lindell F. Killian, ASCS 2, and Nicolaus P. Neumann, P.E. 3 A Case History Facility managers and HVAC engineering supervisors have limited budgets to handle all maintenance and repair needs. As a result, some Air Handler Units (AHUs) containing coil systems 6 to 12 inches thick or greater can become severely blocked. As an alternative to expensive coil replacement, we have developed methodologies that can restore original airflow and pressure drop characteristics. This paper examines a case study of 20 AHUs in a research facility located in St. Louis, Missouri. An article entitled Coil Cleaning: Myths and Misrepresentation appeared in the 2003 September/October issue of DucTales, questioning the validity of coil cleaning methodologies for AHUs containing 6-inch thick (or greater) coil surfaces exhibiting pressure drops exceeding 1.5 to 3 times their original specifications. While we agree with the authors recommendation for an aggressive preventative maintenance program including coil cleaning on an annual basis, we take exception to their conclusion that when actual pressure-drops nearly double their original specifications it is time to change out the impacted coil. Methodologies do exist that significantly reduce pressure-drops, increase airflow, and efficiently remove impacted materials from the core of 6-inch, 12-inch, or greater sized coils. In addition, there could be significant savings on utility expenses to the building owner. Professional Abatement Remediation Technologies (PART), a member of NADCA with three ASCS certified project leaders on staff, provides HVAC system cleaning (including ductwork) to commercial clients and specializes in serving healthcare, food and drug manufacturers, and research-oriented facilities. Based on our years of experience, association with other NADCA member companies, and the guidelines and procedures recommended by the NADCA ACR 2005 we typically clean coils using a high pressure (1000 psi) approach. Three years ago, Washington University School of Medicine (WUSM) hired PART to clean several 12-inch thick coils experiencing pressure drops 2 to 3 times their original specifications. When an independent engineering firm observed little-to-no improvement in pressure drops after a standard high pressure treatment, we modified our procedures to a low pressure, high volume approach, resulting in measured pressure-drops characteristic of their original specifications. Effective coil cleaning and a redesign of the AHUs serving this building resulted in a 30 to 40 percent savings on utility bills for WUSM. 1 General Manager, Professional Abatement & Remediation Technologies, St. Louis, MO 2 Operations Manager, Professional Abatement & Remediation Technologies, St. Louis, MO 3 Principal, Professional Abatement & Remediation Technologies, St. Louis, MO 19

B A C K G R O U N D Many of PART s clients include healthcare facilities and research institutions where indoor air quality (IAQ) requirements are given a significantly higher priority than in most other commercial environments. However, they also experience budgetary constraints and personnel shortages that handicap their ability to handle all preventative maintenance program requirements for all their facilities and equipment. One of our more proactive clients is WUSM in St. Louis, Missouri. Their Clinical Science Research Building (CSRB) is a 10-story facility, housing medical research laboratories, offices, and animal facilities; it was built approximately 20 years ago. From an HVAC perspective, the building is divided in half (A and B sides) with a different AHU serving each side of the floor. Each AHU is designed to provide approximately 20,000 CFM of conditioned air to a space containing a volume of approximately 80,000 cubic feet, thus creating 15 air exchanges per hour or a fresh air turnover every four minutes. The dimensions of a typical CSRB AHU are 25 feet long, 10 feet wide, and 8 feet high (shown in Figure 1). Each AHU contains three distinct coils (reclaim, heat, and cooling) and is compartmentalized as designated in Figure 1: Air Handler Unit Each AHU is designed to provide approximately 20,000 CFM of conditioned air to a space containing a volume of approximately 80,000 cubic feet, thus creating 15 air exchanges per hour or a fresh air turnover every four minutes. Figure 2. A 12-inch thick reclaim coil is positioned between a pre-filter compartment composed of 2-inch pleated sheet filters (MERV 6) and a bank of high-efficiency filters. With only a 2-inch pleated filter between the reclaim coil and fresh air, significant amounts of particulate deposits accumulate on the upstream side of the reclaim coil. About four years ago, WUSM s engineering and HVAC departments were facing a serious air pressure/ ventilation problem in the CSRB building. An independent engineering firm was hired to measure pressure drops and airflow across each coil within all 20 AHUs. Their analysis, taken during the summer of 2000, indicated the second and third coils in the airflow sequence (see Figure 2), the heat coil and cooling coil, respectively, were operating at levels similar to those at the time of installation. However, 16 of the 20 AHUs (80 percent) demonstrated a pressure-drop increase of greater than or equal to 1.5 times the original designed pressure-drop (0.8 1.0 inches) across the reclaim coils. Furthermore, five of the reclaim coils (25%) exhibited pressure- Figure 2: Air Handler Unit Flow Diagram 20

drops greater than 2.0 times their originally designed pressure-drop. In the fall of 2001, WUSM contracted PART to clean the reclaim coil of AHU 3B. The pressure drop across this coil was remeasured and the resultant pressure drop was reduced from 2.68 inches to 2.16 inches as shown in Table 1 Airflow and Pressure- Drop. This pressure variation is almost within the limits of statistical accuracy of the monitoring equipment and suggests that standard operating procedures for coil cleaning, using high pressure High Pressure Coil Cleaning Step Procedure Step washing methods, were not effectively removing the particulate residue blocking airflow within this 12-inch thick coil matrix. P R O C E D U R E S Hundreds of variations of Coil Cleaning exist, varying in temperatures, pressures, and chemicals used; however, the following main steps are involved: O B S E R V A T I O N S On October 8 and 9, 2001, we recleaned the reclaim coil on AHU Note: For a typical 12-inch thick coil, this procedure usually requires 4 to 6 hours for a 2-person crew to complete. Step Procedure 1 HEPA vacuum coil surfaces on both sides until all visible debris is removed. 2 3 4 5 Procedure 1 HEPA vacuum coil surfaces on both sides until all visible debris is removed. 2 Pre-wet coil with a high pressure stream of water and apply coil cleaner. 3 4 5 Allow a 10- to 15-minute dwell time for the cleaner to break down particulate aggregates. Power wash and rinse with pressures up to 1000 psi until no further debris is released. Water temperatures used varied from room temperature to 55 C. Repeat steps 3 and 4 from both sides of the coil until no visible debris or black particulate sludge is being released from the coil. Low Pressure/High Volume Coil Cleaning Step Procedure Pre-wet coil from both sides using a standard 3 4-inch garden hose and nozzle (set to a straight stream approximately 100 psi). Apply water (predominantly from the downstream side of coil) until a stream is observed coming through the opposite side (approximately 20 to 30 minutes). Apply cleaner to both sides of coil and allow a 10- to 15-minute dwell time. We prefer a KOH concentrate manufactured by PUMA Chemical Company. Dilute one part of the cleaner with four parts water and apply 2.5 gallons to each side of the coil with a Hudson sprayer. A thorough pre-wetting enhances the cleaner s ability to penetrate and be distributed more efficiently within the matrix of the coil. Using a garden hose, rinse until water released from opposite side is clear. Always begin rinsing from the downstream side; assuming the upstream side of the coil contains a higher concentration of particulate located closer to the surface. Repeat steps 3 and 4 until the full volume of water released in the flushing step con Note: For a typical 12-inch thick coil, this procedure usually requires 8 to 16 hours for a 2-person crew to complete. 3B using the low pressure/high volume procedure listed below. Our staff observed the release of large amounts of black and rust colored particulate sludge during the first several hours. We continued this process from each side of the coil until no further debris was released. At this point, we observed that water flowed through the entire coil with minimal loss of pressure and exited the coil almost directly across from the point of application. Approximately one week later, the same engineering company was brought in to remeasure the pressure-drop and airflow across the reclaim coil of AHU 3B (results shown in Table 1, Column 3). Their results indicated that airflow dynamics across this coil had been restored to specifications similar to those originally achieved after initial installation of the air handler unit. A few weeks later, this process was repeated for AHUs 9A and 9B, resulting in similar improvements to airflow and pressure drops (Table 1). When using the High Pressure method, our staff observed that even at the end of our cleaning process, very little, if any, of the water applied by power sprayer to one side of a thick coil would even trickle out of the bottom of the opposite coil side. Most likely, the high-pressure approach may clean the first inch or so in from each side of the coil; however, particulate located in the central portion of the coil remained. Even worse, the high-pressure strategy may be compressing and packing the remaining particulate debris in the central core of the coil. Continued on next page 21

Table 1: Airflow and Pressure Drop Saves Time and Money Once a thorough "high volume" cleaning has been performed, preventative maintenance cleaning each year should require less time and cost Air Handler Unit 3B Pre-Cleaning High Pressure Cleaning Airflow NA 15,249 18,536 Pressure Drop 2.68 2.16 0.59 9A Airflow NA 20,699 Pressure Drop 3.24 1.46 Low Pressure/High Volume Cleaning 9B Airflow NA 17,375 Pressure Drop 1.54 0.96 Test results measured by McClure Engineering Associates, St. Louis, MO. H I G H V O L U M E / L O W P R E S S U R E C L E A N I N G B E N E F I T S We have mentioned some of the cost and performance benefits derived from an efficiently operating coil system and AHU; however, there are some additional benefits a well cleaned and rinsed coil system may provide. Since conventional High Pressure cleaning has been shown to leave a residue of sludge inside the coil matrix, we can assume deposits of chemical cleaning agents can also be trapped in this matrix sludge. Several types of cleaners (especially acidic formulations) can be abrasive to coils, causing damage to metal surfaces, rusting of Fe++/Fe+++ containing metals, and oxidation of aluminum fins. In addition, low pressure cleaning eliminates mechanical damage to the coil fins. Once a thorough High Volume cleaning has been performed, preventative maintenance cleaning each year should require less time and cost. C O N C L U S I O N Methodologies do exist to effectively clean severely restricted thick coils in commercial sized AHUs. Equipment requirements are minimal; however, labor requirements are significant. Compared to the cost of coil replacement, the savings are substantial. Based on our success with the reclaim coil in three of the AHUs, WUSM commissioned PART in the spring of 2002 to clean and disinfect all surfaces and coils inside each of the 20 AHUs. Following this work, WUSM retrofitted the control systems and balanced each AHU. A year later, in the spring of 2003, PART met with WUSM s power plant manager who informed us that as a result of our work and re-engineering of the 20 AHUs in the CSRB building, their use of steam for heating the building was significantly reduced. We are informed that savings from WUSM s utility bills will pay for PART s work and the engineering retrofit in just over three years. A C K N O W L E D G E M E N T S The authors wish to thank those individuals who have provided their time, information, and resources to support this project. This includes Tom Brandt, Randy Hensler, Jim Ide, and Jim Stueber (Washington University School of Medicine), as well as Erich Blaufuss (McClure Engineering Associates). Washington University School of Medicine in St. Louis does not endorse commercial products. 22