MSBA Guidelines for Science Labs



Similar documents
TURN-KEY LAB SPACE AVAILABLE

1/9/2015 P:\ \Project Management\Program\Ripon Space Program - 7 January 2015.xlsx

BUILDING NAMING RIGHTS

Clear Creek Business Center 187,865 Sq. Ft. OFFICE/FLEX/INDUSTRIAL

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Designing a Facility: Making It a Place Where Every Student Succeeds

COMPUTER LAB CLASSROOMS. A Planning Guide

FURNITURE and MODULAR OFFICE SYSTEMS

62% 40% 96% 90% 77% 40%

Office Space Guidelines and Allocation Standards

Part 2 Definitions for this Policy 2.1. ADA / TAS the Americans with Disabilities Act / Texas Accessibility Standards.

SECTION XI OPINION OF PROBABLE COST

Kitchen Planning Guidelines With Access Standards

You can do it all yourself. But you don t have to.

THE UNIVERSITY OF EDINBURGH. Number 5 Forrest Hill

Mequon - Thiensville School District Long Range Facilities Plan Monthly Project Schedule

HEALTH FACILITY CHECKLIST SECTION 1226 [OSHPD 3] CLINICS PRIMARY CARE CLINICS

Restaurant & café guide

The Art Institute of Houston Summer 2010 Instructor : Rhonda Jones. 1. Concept Statement 7. One Line Diagram. 2. Program 8. Preliminary Floor Plan

EXHIBIT DISPLAY GUIDELINES

designed delivered installed

Electrical. This section applies to the design and installation of building power distribution systems.

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Element Z General Design Requirements Owner Standards and other Requirements

Cleveland Clinic Room Templates

4 RECORDS STORAGE OPTIONS

OWASSO. Conference Center

Design Questionnaire. Design & Style

Proposed amendments and revisions to the Massachusetts School Building Authority s regulations, 963 CMR 2.00: SCHOOL BUILDING GRANT PROGRAM

School Science Lab Safety Guidelines

ARAPAHOE COMMUNITY COLLEGE

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

KITCHENS REMODELED Before and After

Work Space and Office Furniture Standards December 2014

LIONVILLE PHARMACY FIXTURES

Interior Design IV Gary Leivers AIA, RIBA, LEED AP

NATEF On-Site Evaluation Photo Album

College of Agriculture and Life Sciences Space Management Guidelines. College Space Assignments

SAFETY SELF-INSPECTION PROGRAM

17,280 square feet Overview:

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

RESOURCES. Telehealth. Provincial Health Services Authority. Telehealth & General Meeting Room Design Requirements

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

REQUEST FOR PROPOSALS

SQUARE FOOTAGE REQUIREMENTS FOR USE IN DEVELOPING THE LOCAL FACILITIES PLANS AND STATE CAPITAL OUTLAY APPLICATIONS FOR FUNDING

Laboratory Design & Construction Guidelines

Table of Contents. I Introduction 2. II Definitions & Area Calculation 2. III Room Numbering 7. IV Appendix A 9

Code Requirements for Existing Buildings

LABORATORY CASEWORK. Table of Contents. Laboratory Cabinetry and Specialties. ADVANTAGE laboratory. Series/Model Number Specification...

A1.5 Classroom Standards

One-Wall Kitchen. Ideal Layout For the Small Home

10' 16' Maximum. Backwall 5' 5'

Sample Pharmacy CLEANING AND SANITIZING PROCEDURE P-304.1

ELECTRONIC HEALTH RECORDS AND WRITING SURFACES

5703 South Sossaman Road Aviation Center

EXHIBITION DISPLAY RULES

Laboratory Safety and Environmental Health Assessment Program

BUILDING PERMIT RESIDENTIAL BASEMENT FINISH

Standard boxes plus stock moldings can transform any kitchen from dull and dreary to dazzling and delightful

Videoconferencing Room Guide

Restaurant and Café Risk Management Guide. Don t Risk It!

DESIGN GUIDELINES FOR SUBSTANTIAL REHABILITATION.

Design Development Quality Management Phase Checklist Project Phase Checklist Series

REQUIREMENTS FOR OBTAINING A THORNBURY TOWNSHIP, DELAWARE COUNTY PERMIT

Minimizing Occupational Exposure to Hazardous Chemicals in Animal Protocols

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

2880 International Circle Colorado Springs, CO Telephone Executive Summary Pikes Peak Regional Building Code Revisions

Kitchen planning guide.

EARTHQUAKE SAFETY IN THE WORK PLACE

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

RETAIL DESIGN NEWSLETTER BUILT ON THE BOARDS

New Jersey City University Gilligan Student Union Center

Transcription:

Massachusetts School Building Authority Steven Grossman Chairman, State Treasurer Katherine Craven Executive Director MSBA Guidelines for Science Labs May 26, 2010 www.massschoolbuildings.org

Introduction: Science Lab Task Force Participants MSBA Board members and staff, DESE staff, local architects, construction management consultants, science and technology consultants, science educators, science lab safety consultants Task Force Goals Obtain feedback from experts and practitioners on recent construction and designs Inform MSBA of optimal science classroom / lab design Make recommendations to update MSBA guidelines Massachusetts School Building Authority 2

Introduction: Science Lab Task Force Summary Themes Curriculum should drive design Rooms should be flexible to accommodate all science disciplines and reduce the cost of potential future renovations Create Science lab spaces that are designed to support a variety of science functions to optimize overall utilization Safety must be a top priority overcrowding must be limited Massachusetts School Building Authority 3

Introduction: Science Lab Task Force Discussions Combination lecture / lab classrooms are the norm Fixed demonstration tables limit flexibility and possibility for reconfiguration limit useful space Labs should allow students to work safely Students can easily observe teacher in lecture mode Teacher can monitor all students in lab mode Fixed perimeter with movable peninsulas provides flexibility A stated goal of 85% utilization for general classrooms may not be achievable for science labs Research indicates that the ratio of accidents to square foot per student greatly increase when there is less than 60 square feet per student, or more than 24 students per classroom* * Motz, Biehle and West, The NSTA Guide to Planning School Science Facilities, 2nd Edition, National Science Teachers Association 2007, http://www.ntsa.org Massachusetts School Building Authority 4

Introduction: Science Lab Task Force Recommended Regulation Changes High school space requirements updated Jan 2010: Minimum lab / classroom size updated from 1,200 nsf to 1,440 nsf (60 nsf x 24 students) Science prep rooms increase from 80 nsf to 200 nsf per lab (shared prep rooms, if possible, are preferable) Central chemical storage of 200 nsf added Provide fixed casework around the perimeter only, projecting peninsula / island work stations should be moveable. All utilities should be in the perimeter Massachusetts School Building Authority 5

Introduction: Science Lab Task Force Recommended Regulation Changes (continued) Show small tables with stools in the lecture part of the labs, not chairs with fixed tablets. Tables should match height and finish of perimeter counters The teacher s demonstration station should be moveable, not fixed to the floor All science labs should be provided with water and gas systems, not just the wet labs. (stub systems as required for potential future use) Every science lab should be capable of both lecture & lab arrangement Massachusetts School Building Authority 6

Introduction: Science Lab Task Force Fixed Demonstration Table Restricted area 217 nsf (15% of room) Room Size: 1,475 SF 24 Students / 1 Instructor 25 SF /student 1n Lab Area Image provided by James T. Biehle Inside Out Architecture Massachusetts School Building Authority 7

Introduction: Science Lab Task Force Typical Lecture / Lab Configuration Classroom Area Lab Area Room Size: 1,470 SF 24 Students / 1 Instructor 30 SF / student in Lab Area Image provided by James T. Biehle Inside Out Architecture Massachusetts School Building Authority 8

Prototype Design New York School Construction Authority http://www.nyc.gov/html/sca/home.html 27 6 46 2 28 4 28 4 Room Size: 779 SF 31 Students / 1 Instructor Room Size: 1,307 SF 24 Students / 1 Instructor 27 SF /student in Lab Area Massachusetts School Building Authority 9

Prototype Design New York School Construction Authority http://www.nyc.gov/html/sca/home.html 46 2 46 2 28 4 28 4 Room Size: 1,307 SF 34 Students / 1 Instructor 38 SF /student in Lab Area Room Size: 1,307 SF 40 Students / 1 Instructor 32 SF /student in Lab Area Massachusetts School Building Authority 10

Prototype Design Chicago Public Schools http://www.cps.edu Chicago Public Schools Capital Improvement Program Science classroom design guide 45 6 24 Perimeter counters are provided without base cabinets underneath The labs are smaller than MSBA (1,100 sf) and have more students (28 + one teacher, 39 SF per student) The Teachers demonstration table is fixed The student tables have adjustable height metal legs 3 Treatment Levels provide one fume hood per school, and gas in 25% of the labs. The remaining 75% of the labs get 3 sinks each Level Gas Distribution Fume Hood Student Work Sinks No. of Spaces Required at a High School 1 Yes Yes 7 1 Instructional Space 2 Yes No 7 25% of Total Spaces 3 No No 3 All Remaining Spaces Massachusetts School Building Authority 11

Notes Conclusion: MSBA Prototype Design The following diagrams are examples of table arrangements that can accommodate a wide variety of activities, groupings, and instructional configurations that are typical of laboratory work and instruction in small, medium, and whole-class groups. The intent is to design spaces with maximum flexibility for varied uses without extensive reconstruction. The following plans are to be considered standard template configurations; specific school designs may vary from these standards. The items described as "requirements" are mandatory, other items are MSBA recommendations are to be considered "best practices." Massachusetts School Building Authority 12

Conclusion: MSBA Prototype Design Requirements The MSBA allotment of 1,440 nsf for each science lab is based on 60 nsf per student (24 students). Smaller science classrooms may be considered if the class size is smaller, with a minimum of 60 nsf per student. The district and design team should provide for a science lab layout that allows as much flexibility and universality as practical, given the districts science department educational plan. Both lab and lecture configurations must be accommodated in every designated science lab room. Separate labs and lecture rooms are not permitted. No raised lab utilities, that may restrict flexibility, are to be provided in the central floor area of the science labs. Utilities from a grid suspended from the ceiling may be needed for some disciplines, but only if the peripheral utilities cannot accommodate most needs. No fixed casework is permitted in the central floor area. Massachusetts School Building Authority 13

Conclusion: MSBA Prototype Design Best Practices Sturdy, standing-height two-student tables should match the height of peripheral countertops so that students perform lab work standing (preferable) and "seat work" on stools. Two-student tables (not larger) are recommended so they can be moved into a variety of configurations. Adjustable-height tables are not recommended. Stub utilities where needed for potential future configurations. Sinks should be wide and deep enough to accommodate buckets and other large containers. Optional fume hoods and bio-safety cabinets should be accessible from both the prep room and the classroom. Provide full black-out window treatment in labs. Provide moveable teacher demonstration tables. (not fixed) Each lab prep room should include one refrigerator and one dishwasher. Massachusetts School Building Authority 14

Conclusion: MSBA Prototype Design Best Practices (continued) Provide visual access between labs and prep rooms / prep room doors. Shared spaces can be reduced in area, with saved areas reallocated elsewhere as needed. Prep rooms and chemical storage should be keyed in such a way to provide limited access, for required personnel only. At the districts discretion, chemical storage can be divided into satellite storage rooms, but chemical storage in prep rooms is discouraged. Safety equipment and information such as fire blankets, sterile eyeprotection, and material safety data sheets (MSDS) should be located in highly-visible and easily-accessed places, preferably near exits and other required safety equipment. Rather than green houses, consider designs that allow plants to be placed on shelves or moveable racks with access to light from classroom windows. At least two means of egress from each lab should be provided (the building code may require this, depending on area). Massachusetts School Building Authority 15

Conclusion: Prototype Design Scheme A Front Facing / Large Group Instruction / Teams of 2 Configuration Room Size: 1,440 SF 24 Students / 1 Instructor 60 SF /student in Lab Area Lab Configuration 1 Room Size: 1,440 SF 24 Students / 1 Instructor 60 SF /student in Lab Area Massachusetts School Building Authority 16

Conclusion: Prototype Design Scheme B Ramp / Motion Studies Configuration Lab Configuration 2 Room Size: 1,440 SF 24 Students / 1 Instructor 60 SF /student in Lab Area Room Size: 1,440 SF 24 Students / 1 Instructor 60 SF /student in Lab Area Massachusetts School Building Authority 17

Conclusion: Prototype Design Scheme C (showing chemical storage room) Mid-size group / Robotics Configuration 1 Mid-size group / Robotics Configuration 2 Room Size: 1,440 SF 24 Students / 1 Instructor 60 SF /student in Lab Area Room Size: 1,440 SF 24 Students / 1 Instructor 60 SF /student in Lab Area Massachusetts School Building Authority 18

Conclusion: Prototype Design Egress Calculation 1,258 NSF Movable Tables 1,097 NSF Fixed Demo Table and Peninsula Table 1004.1.1 educational occupancy (classrooms) assumes 20 SF of net floor area per occupant (that goes up to 50 SF per occupant for shops and other voc tech rooms).* Table 1015.1 educational occupancy max load of 49 occupants for rooms with one means of egress.* Therefore 2 means of egress is required for any classroom with greater than 980 SF of net area (exclusive of built-in casework, fixed equipment, etc). * 8 th Edition Massachusetts State Building Code Massachusetts School Building Authority 19