STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES



Similar documents
STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Industrial Cable Solutions for Variable Frequency Drives

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Installation and Application Guide. for 600V Conductors

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

MANUFACTURER S CERTIFICATE OF COMPLIANCE

ADDENDUM 1. This Addendum forms part of and modifies Proposal Documents dated, December 10, 2015, with amendments and additions noted below.

STREETLIGHT SYSTEM GROUNDING AND BONDING

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Generator DoCKInG StatIonS

Type XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor

The MC Cable Revolution is Gaining Ground REMKE

100% EMI Emission Containment

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

Electrical Grounding. Appendix C

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

Building Cables and Wires

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

SECTION SIGNAL WIRE AND CABLE

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

Requirements for Electrical Installations

Short Circuit Current Calculations

Ontario Electrical Safety Code 25 th Edition/ 2012

Over land, over sea, overcoming solar, wind power transmission challenges

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Solar Water Heating and Photovoltaic Electrical Systems Installed on One or Two Family Dwellings

Gexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Electrical Design Training Class Ampacity WSDOT Winter 2008 BZA

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

SUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND

Contact Hueson Corporation for additional information or details Sutton Street Northbridge, MA

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Solar Power Solutions

Chapter 9. Bonding and Grounding

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

SECTION /600 VOLT CABLE, WIRE AND CONNECTORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

MESSENGERS FOR AERIAL CABLE

TABLE OF CONTENT

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Your Only Solution for All Variable Frequency Drive Applications

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

CHAPTER 2 EXAMPLES AND TABLES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Instrumentation Cable Power Cable Assembly Solutions...32

DIRECTCONNECT SERVICE

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

CITY OF LOS ANGELES CALIFORNIA

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Cable Installation Notes

ELECTRICAL: WIRE, CABLE, AND TERMINATIONS

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

A COMPARISON OF ALUMINUM VS. COPPER AS USED IN ELECTRICAL EQUIPMENT

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

RoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables

Electrical Code Regulation

Three-Phase Electric Power Distribution for Computer Data Centers

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

ALUMINUM ELECTRICAL WIRING

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

CCW Continuously Corrugated Welded Cable A RMORED CAB LE FO R HAZAR D O U S LOCATI O N S

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Hyperlinks are Inactive

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

Security & Control Cables

Lifeline Fire Protection Cable Systems. Cables

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

How To Plan Out An Array Of Solar Panels

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

MOBILE HOME SERVICE REQUIREMENTS GAS

City of Riverside Building & Safety Division Phone: (951)

3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation

Power. When and where you need it.

How To Wire Wire Wire For A Decoder System

NEC 2014 Code Changes

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

2012 CATALOG AEROSPACE VVIRE & CABLE INC. aerospacewire.com

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Heating Cable. Construction

How to Estimate the Cost of a Clean Room and Data Center Equipment Electrical Work. Section 2 Types of Methods of Measurements page 4

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Teledyne Cable Solutions

PHOTOVOLTAIC ARRAY WIRING HANDBOOK FOR STANDARD NOMINAL 6, 12, 24, AND 48 VOLT SYSTEMS. (for SX-60 series or smaller and MSX-120 solar modules)

Transcription:

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

Introduction General Cable understands that assisted living facilities require complex building designs that must address a wide range of systems and applications. That is why our STABILOY Brand aluminum alloy feeder cables are installed with confidence in a variety of elder care facilities in North America including: Independent Living Retirement Communities Continuing Care Retirement Communities (CCRC) Senior Housing / Apartments Memory Care Facilities Nursing Homes Hospice Facilities The STABILOY Brand of products includes MC Cable, FeederPlex HS XHHW-2 cable, and single conductor WIDESTRIPE HS XHHW-2 cable, which are designed to distribute power throughout the building. Each of these cable solutions provides significant cost savings and reliable performance. STABILOY Brand MC Cable offers a durable interlocked aluminum armor to protect the electrical conductors from damage, while allowing flexibility in construction and design. The all-in-one assembly of MC Cable makes it a cost-effective solution for electrical retrofits in existing buildings. STABILOY Brand single conductor WIDESTRIPE HS XHHW-2, a phase-identified, low coefficient of friction cable, can be used in EMT, PVC or other types of conduit. Our FeederPlex HS XHHW-2 cable is a factory-plexed assembly of XHHW-2 conductors that allows for fast and easy cable pulls while eliminating the need to pull multiple conductors from separate reels. So whether you are installing in conduit or not, STABILOY Brand aluminum alloy feeder cables offer you a safe, reliable and cost-effective solution for distribution feeder applications. Quality is never a question with STABILOY Brand cables. In fact, General Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Each STABILOY Brand single conductor and FeederPlex HS assembly is tested using state-of-the-art AC spark testing technology to ensure product quality. The superior performance of STABILOY Brand aluminum alloy cables has been validated by independent research. The Georgia Power Research Laboratory conducted a study comparing STABILOY Brand feeders to copper conductors. The results of the study show that connections installed on AA-8000 series aluminum alloy performed as well as or better than connections installed on copper conductors of equivalent ampacity in the current cycle submersion test. STABILOY Brand aluminum alloy is readily available, infinitely recyclable and is manufactured in an environmentally responsible manner. STABILOY Brand feeders contain no heavy metals and are RoHS* compliant, and the cable jackets are free of lead and cadmium stabilizers. There s no question: green construction is the building trend of the decade. However, in today s tough economy, it is crucial to cut costs while considering the environmental impact of our building material choices. By including STABILOY Brand MC Cable in your project specifications, the savings you realize can be used to defray the cost of energy-saving devices and accelerate the payback of your assisted living facility. For more information on General Cable, call toll-free at 855-720-2792.

APPLICATION STABILOY Brand conductors and cables are UL Listed and can be used for services, feeders and branch circuits. Service and feeder conductors to the main distribution center in a variety of buildings including: independent living retirement communities, continuing care retirement communities, assisted living, senior housing, memory care facilities and nursing homes. Feeder conductors for power distribution to the panel throughout a variety of building constructions including: wood stud, metal stud, concrete poured and cinder block. Feeder and branch circuits for a variety of specialized equipment and HVAC services. Temporary services and feeders for power throughout the construction phase. Our Metal Clad cable with PVC jacket can be used in exterior locations including wet locations and those exposed to sunlight. PROJECTS LIST Stayton Retirement Center Fort Worth TX Allegro At Willoughby Assisted Living Facilities Stuart FL Englefield Senior Housing Boise ID Solera Transitional Care Facility Houston TX Bel Air Health Care Center Milwaukee WI CC Young Overlook Independent Living Complex Dallas TX Little River Nursing And Rehabilitation Ashdown AR The Crescent Skilled Nursing Facility Sugar Land TX Coronado Continuing Care Center San Antonio TX SPECIFICATIONS Field Application Engineers are on staff to help you navigate the electrical specification process including takeoffs and voltage drop calculations. FAEs also serve as a resource for specification changes, value engineering proposals and technical questions. To gain the maximum value benefit on your project, specify STABILOY Brand 8000 Series aluminum alloy as an alternative in the Master Electrical Specification. A sample specification is included below for reference. 600-VOLT INSULATED CONDUCTORS A. All branch circuit conductors and feeder conductors 10 AWG and less shall be soft-drawn annealed copper with conductivity of not less than 98% IACS at 20 degrees C (68 degrees F). Conductors greater than 10 AWG copper may be converted to aluminum at the contractor s option. The contractor shall be responsible for increasing the conductor and conduit sizing, if necessary, when aluminum conductors are substituted for copper. The ampacity of the aluminum conductor shall be adequate for the load served and sized appropriately for the overcurrent device. The conduit fill shall not exceed NEC requirements. B. Conductors 10 AWG and smaller shall be solid and conductors 8 AWG and larger shall be stranded. Minimum wire size shall be 12 AWG unless otherwise noted on the drawings. C. All wire and cable shall be permanently marked to indicate size, voltage, type and temperature rating in accordance with NEC Article 310 and applicable product standards. D. Provide factory colored insulation for phase conductors 10 AWG and smaller. Larger insulated phase conductors may be factory identified with an approved field applied tape. E. Aluminum conductors shall be as follows: Type XHHW-2: For dry and wet locations, maximum operating temperature 90 C. The conductor shall be compact stranded AA-8000 series aluminum with black cross-linked polyethylene insulation. The cable shall meet the requirements of Federal Specification JC-30B. The conductor shall comply with ASTM Standards B800 and B801 or B836. ALUMINUM CONNECTORS AND TERMINATIONS A. All connectors and terminations shall be UL Listed for use with aluminum conductors. All connectors and terminations shall comply with UL Standard 486A-B and be marked "AL", ALCU, "AL7CU or AL9CU for 90 C circuits. B. All connections and terminations shall be made in accordance with the connector or equipment manufacturer s recommendations. C. Tighten electrical connectors and equipment, including screws and bolts, in accordance with manufacturer s published torque tightening values. Where manufacturer s torquing requirements are not indicated, tighten connectors and equipment to comply with tightening torques specified in NEC Annex I.

STABILOY Brand Aluminum Feeder Cable The Value of Aluminum: Superior Conductivity, Insulation & Termination Did YOU Know? STABILOY Brand aluminum feeder cables are the hardest working conductors on the market. Conductivity When it comes to conductivity, aluminum conductors carry twice the current per pound as copper conductors, giving STABILOY Brand aluminum alloy conductors a distinct performance advantage. Insulation STABILOY Brand aluminum alloy conductors feature a superior crosslinked polyethylene (XLPE) insulation that performs better in cold impact, wet locations and long-term aging tests compared to other types of conductors. This makes it a better insulation for every building wire application. Termination STABILOY Brand aluminum alloy conductors terminate safely with industry standard dual-rated aluminum alloy lugs. The similar metals connection eliminates thermal expansion mismatch, which translates into a safe and reliable termination. Quality It s a fact. General Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Because STABILOY Brand aluminum alloy feeder cable is 100% tested for quality its reliability, durability and safety are all guaranteed! Performance High-quality STABILOY Brand aluminum alloy features a unique composition of metals that is specially engineered for superior performance in building feeder applications. Confidence You can rest assured. If aluminum is the utility companies preferred choice for carrying power all the way from the generator to the grid, it s the right choice for the last 100 feet of power delivery feeder cable. Ease-Of-Use STABILOY Brand aluminum alloy feeder cable is much easier to install. Maintenance for STABILOY Brand and copper is equal. This makes it more time-efficient and more cost-effective as well. Value At twice the ampacity per pound, not only is aluminum more cost-effective than copper, but the price of aluminum is much more stable than the price of copper. Sustainability Aluminum alloy is readily available and infinitely recyclable. In addition, STABILOY Brand aluminum alloy conductors are manufactured in an environmentally responsible manner.

Products MC Cable An all-in-one XHHW-2 conductor assembly with phase-identified conductors and a bare equipment grounding conductor. The assembly is a no conduit solution that provides labor and material savings of up to 50% over copper in conduit. STABILOY Brand MC Cable is available with and without a PVC jacket. FeederPlex HS XHHW-2 Factory-plexed assembly of aluminum alloy XHHW-2 conductors with specially designed XLPE insulation that allows for fast and easy pulling. Designed with phase identification for safer connections and delivered on one reel to the job site. STABILOY Brand FeederPlex HS significantly reduces installation time and effort during the pull, and minimizes site management. WIDESTRIPE HS XHHW-2 A single conductor aluminum alloy feeder cable with a specially designed XLPE insulation that allows for fast and easy pulling. Phase identification on the conductor consists of three wide color stripes embedded within the surface of the insulation. The insulation on STABILOY Brand WIDESTRIPE HS (High Speed) XHHW-2 conductors reduces pull force by 42% compared to the installation of regular XHHW-2 using pull lube. STABILOY Brand XHHW-2 A single conductor feeder with cross-linked polyethylene (XLPE) insulation that provides better performance than THHN insulation in hot and cold weather conditions, wet locations, higher short circuit temperatures and long-term aging tests. CASE STUDIES Stayton Retirement Center Fort Worth, Texas Product: XHHW-2 Why STABILOY Brand? The Stayton is a new concept in retirement living: an urban village concept, offering four levels of health care for seniors. The Crescent Skilled Nursing Facility Sugar Land, Texas Product: XHHW-2 Why STABILOY Brand? This 112 bed skilled nursing facility cares for patients recovering from a serious illness or requiring advanced therapy services after a hospital stay. www.stabiloy.com

4 Tesseneer Drive, Highland Heights, Kentucky 41076-9753 GENERAL CABLE, STABILOY Brand, FeederPlex HS and WIDESTRIPE HS are trademarks of General Cable Technologies Corporation. NEC is a registered trademark of the National Fire Protection Association. 2014. General Cable Technologies Corporation. Highland Heights, KY 41076 All rights reserved. Printed in USA Phone: 855.720.2792 1.859.572.8000 Fax: 1.800.547.8249 www.stabiloy.com Form No. BW-0107-0514