Advanced Intelligent Modules. Overview. Description

Similar documents
Fire detection equipment

D287/D288/D292/D293A/D293E

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

conventional system operation

Fire Detection Product Range

VEGA Analogue Addressable Control Panels

Triple Waveband Infra-Red Flame Detection

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

FIREDEX Conventional Fire Panels

AlarmSense 2-wire detection and alarm system. Product Guide

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Fire Alarm System Accessories

DUCT SMOKE DETECTOR D4120

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

WD-AMX Water Detection Controllers

MSL1000 Monitored Serial Link Interface Manual V1.01

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

TrueAlarm Fire Alarm Systems

MINERVA MX MX Virtual Multi-Sensor Detectors

Conventional Fire Detection and Extinguishant Control System Specification

EQUIPMENT SPECIFICATIONS

Rosemount 333 HART Tri-Loop

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Life Alarm Fire Alarm Controls

8900 EMR (WITH DETECTOR)

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

SECTION DETECTION AND ALARM

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

SILENT KNIGHT MODEL 5207

INSTALLATION MANUAL PC2525. Version 1.1

Global System Technology(UK) PLC The Intelligent Solution

INTERFACING SECURITY SYSTEMS TO HOMEVISION

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

RY2 miniature industrial relays


A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Rosemount 333 HART Tri-Loop

GAE953 Electrical Alarm Unit 19" with Indicator

Solid-State Timer H3G

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

OPAL TM Detector range

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

Fire. The Fire Installers Mate. A guide to fire alarm systems design

FX 3NET + SLC FIRE ALARM SYSTEM Part 1: General Rules

IO-RM3 3-Stage Relay Module

General Purpose Relays Accessories. Accessories Miniature Relay PT

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Concierge. Outdoor panels

ATS - Automatic Changeover

Passive Infrared Motion Detector 5420/90. Installation Instructions

Control/Communicator Installation Manual

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

PowerCode Wireless. Fully supervised wireless system. Features

Combi B Alarm box. Mounting instructions

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SMART SENSOR COLLECTION

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

CB200W Water Leak Detection Panel Application Guide

Model: DC-A2IO Advanced HVAC Controller

HERZ-Thermal Actuators

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

IO-DIM6 6-Channel, Digital to Analogue Converters

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

EMF/EMR. Holder/Release Devices with Integral Door Closers

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

DLP-PU/E Instruction Manual

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Fire Detection System. for Wind Power Plant

HM-W536 Install Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Process Alarm Solutions

Busch-Watchdog Presence EIB Type:

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

C2O CALL 2 OPEN USING YOUR CELL PHONE. Operation. Features Ready to operate Straight from the Box! O/P Changeover Contact 1.2KW

Control and Indicating Equipment

Transcription:

Overview Features M200XE Short Circuit Isolator Module M201E Single Output Module M210E Single Input Module M210E CZ Conventional Zone Module M220E Dual Input Module M221E Dual Input Single Output Module Common mechanical platform for box, panel and DIN rail mount versions Tri-colour LEDs Built-in short circuit isolators Decade address switches visible and selectable in two planes Wide angle LED visibility LPCB Approved VdS Approved BOSEC Approved:TCC2 K 466 GEA GEI 1 1-082 and CEA GEI 1-084 Approved Designed to meet VdS 2489 199r/01 199q/01 G202137 199q/02 199q/03 G202139 199q/04 199q/05 G202140 199q/06 G202141 Description The new family of input/output modules form part of Advanced Intelligent family. Single and multi-way models are available within the same mechanical package, reducing both the cost of installation and the mounting space required. Their unique mechanical design allows each module to be mounted in either a wall box, on a DIN rail or within any type of enclosure. Irrespective of the mounting methods chosen, the address switch is both visible and accessible for selection. To facilitate the interconnection of DIN rail mounted modules, packs of pre-cut and stripped lengths of wire are available. The part number for these packs of wire is M200-LWP. Each module has built-in short circuit protection for the communications loop; however, to increase application flexibility, the isolators can be selected/ deselected on an individual module basis. To help technicians in the maintenance and faultfinding process, both the LEDs and the switches can be viewed without having to remove the cover of the surface mounting box. The LEDs, being multi-colour, provide diagnostic information regarding the status of each individual input/output. For ease of installation, testing and maintenance, the field wiring terminals are of plug-in design.

M200 Series Input/Output Modules M210E Single Input Module, M220E Dual Input Module and M221E Dual Input Single Output Module The M210E and M220E provide supervision of one or two input circuits respectively from external devices; the M221E also provides an unmonitored single pole volt-free changeover contact for external devices. All modules feature a built-in short circuit isolator. Input channels are capable of both latched and analogue supervision: there are three separate latched states, normal, open circuit and combined alarm/short. The analogue supervision continuously monitors the supervised circuit, returning a signal proportional to the circuit resisitance. 15 to 30VDC M210E Maximum Standby Current 310μA at 24VDC, no communications 510μA at 24VDC, One communication each 5 seconds with LED blink enabled M220E Maximum Standby Current 340μA at 24VDC, no communications 600μA at 24VDC, One communication every 5 seconds with LED blink enabled M221E Maximum Standby Current 340μA at 24VDC, no communications 60μA at 24VDC, One communication every 5 seconds with LED blink enabled M221E Output Rating 2A at 30VDC, resistive load. 5 to 95% Relative M210E 100g M220E and M221E 110g

M210E-CZ Conventional Zone Module The M210E-CZ provides an interface between a zone of conventional detectors and an intelligent signalling loop. The module is fitted with in-built short circuit isolation, so that if a short circuit fault in the conventional zone occurs, it will be isolated from the loop. When the line voltage rises above the fixed threshold, the isolator module will detect the removal of the fault condition and automatically restore power to the isolated group of devices. The module uses a capacitive EOL to monitor the conven-tion zone and transmits the zone state (normal, open or short fault and alarm) to the panel. 15 to 30VDC (18 to 30VDC if the conventional zone is loop powered) Maximum Standby Current external powered zone 288μA at 24VDC, No communications 500μA at 24VDC, One communication each 5s Maximum Standby Current, loop powered zone 1.5mA at 24VDC, One communication each 5s 5 to 95% Relative 110g

M200 Series Input/Output Modules M200XE Short Circuit Isolator Module The M200XE is intended to be spaced between groups of devices on a communication line to protect the line if a short circuit fault occurs. It automatically opens when the voltage in the communication line falls below a fixed threshold. If a short circuit fault occurs, the two isolators located around the device group where the fault occurred will sense the line voltage drop, open their switches and remove the devices from the rest of the line. When the line voltage rises above the fixed threshold, the isolator module will detect the removal of the fault condition and automatically restore power to the isolated group of devices. 15 to 30VDC Maximum Standby Current 200μA at 24VDC Fault Detection Delay 100 to 400ms Maximum On Resistance 0.13 at 15V 5 to 95% Relative 62g

M201E Single Output Module The M201E optionally supervises the wiring to the load devices and, upon command from the control panel, switches an external power supply to operate these devices. It also has built-in short circuit isolation capability. In normal supervised mode, the device switches out the load supervision and switches in the external power supply through a double pole relay. The external power supply is monitored and raises an unlatched fault condition if the voltage falls below the fixed threshold. In the unsupervised mode, the device provides neither load nor power supply supervision and can be used to switch a single form C set of changeover contacts. A field selectable DIL switch allows the module to be used to fully meet the VdS 2489 requirements (subject to panel support). Note: selecting this option imposes an additional restriction on the load that can be switched. 15 to 30VDC Maximum Standby Current 310μA at 24VDC no communications 510μA at 24VDC, one communication each 5 seconds with LED blink enabled Relay Specifications Normal and unsupervised form C ratings 2A at 30VDC, resistive load 5 to 95% Relative 62g

Advanced Intelligent Modules Input/Output Modules Bulkhead and DIN Rail Mounting Brackets 24mm 134mm 40mm 139mm List of Accessories M200E SMB M200E SMB KO M200 DIN M200 PMB M200 LWP Surface Mounting Box Surface Mount Box with 20mm knockouts DIN Rail Mounting Clip Panel Mounting Clip Pack of 200 pre-stripped wire links Other Modules in the range (see separate datasheets) M201E 240 M201E 240 DIN SC 6 SR 6 CZ 6 Mains Switching Output Module DIN rail mount 240V Mains Switching Output Module Supervised Control Output 6-way Relay Output 6-way Conventional Zone 6-way ADEVA LTD. Fire Alarm Systems Guldeste Sok. No:24 Yakacik Kartal / Istanbul / Turkey Tel: +90 (0)216 5982800 Fax: +90 (0)216 5982899 Email: info@adevafire.com www.adevafire.com Copyright 2009 ADEVA. All rights reserved. All technical data is correct at time of publication and is subject to change without notice. All trademarks acknowledged. Installation information: in order to ensure full functionality, refer to the installation M200-09