Power-Zone 4 Arc Resistant Low Voltage Switchgear

Similar documents
Enhancing Personnel Safety with Arc Resistant Equipment

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Low Voltage Switchgear

Sample - No Commercial Use

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Arc Terminator Active Arc-Resistant Switchgear

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Electrical Distribution Services for Mining and Metals Industries

2008 Eaton Corporation. All rights reserved.

UL Validated Testing of Arc-Resistant Motor Control Centers

Choosing the Best Solution for Reducing Arc Energy

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

How to reduce exposure to arc flash hazards

Siemens tiastar TM Motor Control Center (MCC) Siemens All rights reserved.

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Secondary Unit Substations

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

APPLICATION FOR OSHPD SPECIAL SEISMIC CERTIFICATION PREAPPROVAL (OSP)

Contents. Description. Product Selection Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Switchgear and Metal-Enclosed Bus

Engineers Edge, LLC PDH & Professional Training

IR WINDOW CERTIFICATION GUIDEBOOK. Copyright CorDEX Instruments Ltd. ex.com. ID 4016 Rev A

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Defining the Needs of Modern Data Center Power Systems, Low Voltage Circuit Breaker Application

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Bypass transfer switch mechanisms

Instructions for Eaton 7.2kV AMPGARD Arc Resistant Motor Control Centers

Understanding the Standards Surrounding Arc Flash Hazards and Arc Resistant Equipment

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

What s up with Arc Flash?

Roadmap to Compliance with NFPA 70E Arc Flash Requirements

Extend the Life of Existing Switchgear

Unified requirements for systems with voltages above 1 kv up to 15 kv

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

FAQs-Main switchboard design criteria

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

The following components are common to most cubicles; this example is an ABB HK cubicle.

The Intelligent AX1 Switchgear for Medium Voltage

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Understanding Arc Flash

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

SECTION 16426C ARC RESISTANT DRAWOUT SWITCHGEAR (MAGNUM DS) LOW VOLTAGE

Addendum #2 Contract UK-11-13

Medium Voltage Motor Control Assemblies

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

Reliability requires consulting engineers and end users to grasp design, maintenance basics. By Reza Tajali, P.E. Square D Power Systems Engineering

Alternate Methods to Short Circuit Breaker Coordination

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Masterclad 5 15 kv Arc Resistant Metal-Clad Indoor Switchgear

Safety By Design. Strategies for Electrical Contractors

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Atlanta Chapter IEEE Industry Applications Society

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

8146/5 Series Breaker Panelboards

MCC Ratings. Voltage Rating

Installation Instructions for Alarm Module Kit A043F059

ELECTRICAL SAFETY RISK ASSESSMENT

NFPA 70E Updates Affect Your Most Valuable Assets

Vilter motor starter solutions The NEW industry standard in motor starter packages

Designing for Safety: ABB Medium Voltage Switchgear and MCC

Medium voltage VCP-W MR2 (integral racking)

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Arc Flash Energy Mitigation Techniques

Type GM-SG-AR 5 kv and 15 kv arc-resistant metal-clad switchgear instruction manual. Answers for energy.

Electrical Distribution Services from Schneider Electric

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

Safe and secure distribution of medium voltage with AX1

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

LVA Take Offs in Bid Manager

Session Four: Internal Arc Safety in New and Existing Switchgear

misconceptions about arc-flash hazard assessments

Application of Four-Pole Circuit Breakers within Data Centers

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Mitigation of Arc-Flash Hazards and Reduction of Costs by Selective Arc-Flash Protection

Transcription:

Power-Zone 4 Arc Resistant Low Voltage Switchgear with ArcBlok Technology Make the most of your energy SM

Workplace safety 2 I Power-Zone 4 Arc Resistant Low Voltage Switchgear

Five to ten arc flash explosions occur in electrical equipment every day in the United States, according to statistics compiled by CapSchell, Inc., a Chicagobased research and consulting firm that specializes in preventing workplace injuries and deaths. As regulations imposed by OSHA, through NFPA 70E, on end users regarding worker safety continue to become more stringent, the market is moving toward arc-resistant solutions. Dangerous electrical events such as an arc flash can cause injury or even death to personnel along with tremendous equipment damage that results in substantial financial consequences. Reducing the occurrence of these incidents, as well as containing the effects of an arc flash event once it occurs, is essential to reducing risk to personnel. With over 100 years of experience and a commitment to innovation, Schneider Electric has developed a full line of arcresistant solutions to create an advanced level of protection for personnel in the work environment. Power-Zone 4 Arc Resistant Low Voltage Switchgear I 3

ArcBlok Technology: An arc extinguishing solution The Power-Zone 4 Arc Resistant Low Voltage Switchgear with ArcBlok technology by Schneider Electric features the proven reliability and durability of Masterpact NW power circuit breakers with a new, unique combination of arc flash mitigation features and advanced arc flash containment. Masterpact NW with ArcBlok technology helps quench and transfer an arc before it propagates inside the breaker compartment. Our unique technology provides a superior level of protection from the consequences of internal arcing faults without increasing the footprint of the equipment. Arc flash energy containment occurs on the front, back, and sides, even when the instrument compartment door is open, complying with ANSI Type 2B rating. This simple, stand-alone circuit breaker solution is a space-saving design that offers an additional level of protection for personnel. Plus, Power-Zone 4 Switchgear with ArcBlok technology features simple installation and reduced maintenance and inspection requirements. Power-Zone 4 Arc Resistant Low Voltage Switchgear with ArcBlok technology Best-in-class arc fault containment 100 kair at 635 Vac UL tested and certified to ANSI Type 2B ArcBlok circuit breakers extinguish the arc in 5 to 15 msec when arc is in the rear of the breaker cell The ArcBlok design extinguishes the arc at the rear of the circuit breaker cell reducing the damage and eliminating the need for special seals on the cell door Formex insulating barriers provide phase-to-phase and phase-to-ground isolation ArcBlok offers positive seal and phase-to-phase and phase-to-ground isolation in all three racking positions (connected, test, and disconnect)* *Door should remain closed and latched to maintain arc containment rating ANSI Type 2B enclosure rating Arcing does not cause holes in the freely accessible front, sides, and rear of the enclosure or in the walls isolating the low voltage control or instrument compartment(s). 4 I Power-Zone 4 Arc Resistant Low Voltage Switchgear

Advanced technology Cluster shields Designed to prevent arcing events by enclosing the phases at the primary connections of the breaker and cradle. Cluster shields provide additional extinguishing if an arcing event occurs inside the circuit breaker compartment. The shields help minimize equipment damage. Cradle shields Corresponding and overlapping shields within the cradle provide phase-to-phase and phase-to-ground isolation in the connect, test, and disconnect positions with doors closed and latched. Arc ventilation The ArcBlok circuit breaker is engineered for maximum heat and arc transfer utilizing its chimney-like design. Power-Zone 4 Arc Resistant Low Voltage Switchgear I 5

Power-Zone 4: Enhanced arc flash containing features Enhanced internal design redirects arc flash gas and plasma away from personnel. The roof flaps, floor, and internal baffle assembly operate cohesively to provide equipment ventilation and improved arc flash protection. Exhaust designs Roof baffles and optional plenum Engineered and designed to provide advanced pressure relief through the top of the gear, channeling dangerous energy away from personnel. The roof flaps open to relieve pressure as plasma is channeled up and out the top of the equipment. Enhanced ventilation The innovative ventilation system allows for a dead-front design. The rear intake vents, combined with the spring-loaded floor dampener, channels air into the gear, optimizing the equipment s natural convection. The spring-loaded floor damper slams shut during an arcing event, creating a positive seal. Power-Zone 4 with integrated arc flash containment features 6 I Power-Zone 4 Arc Resistant Low Voltage Switchgear

Standard features Industry-leading withstand rating of 100 ka @ 635 Vac ArcBlok technology for superior arc flash protection NEMA Type 1 enclosure with ANSI Type 2B rating 60" deep and 22" wide design allows for the smallest footprint in the industry Complete line of Masterpact NW breakers available up to and including 5,000 A Field-interchangeable Micrologic trip units Bus ratings up to and including 5,000 A Enhanced ventilation system optimizes heat transfer Optional features Insulated copper bus Plenums Zone Selective Interlocking system High resistance grounding Energy reduction maintenance switch Breaker remote racking Overhead breaker lifter Standards UL certified and tested in accordance with ANSI C37.20.7 ANSI C37.20.1, ANSI C37.51 Certified to Canadian Standard C22.2, No. 31 UL 1558 ANSI C37.13, ANSI C37.16 ANSI C37.17, ANSI C37.50 UL 1066 Power-Zone 4 Arc Resistant Low Voltage Switchgear I 7

Sample guide form specification for Power-Zone 4 Arc Resistant Low Voltage Switchgear This section supplements Section 26.23.00.11 AR Low Voltage Switchgear, unless otherwise noted. Comply with requirements of latest revision of ANSI/IEEE C37.20.7 Guide for Testing Metal-Enclosed Switchgear Rated up to 38 kv for Internal Arcing Faults. Take the next step, advance the level of safety at your facility with the Power-Zone 4 Arc Resistant Switchgear. Whatever your requirements for switchgear are, we have a solution to meet your needs. For assistance or more information, contact www.schneider-electric.com/us or call at 888-778-2733. Schneider Electric USA 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7500 www.schneider-electric.com/us Document Number 6000BR1206 Arc Resistant Electrical Ratings: Nominal AC System Voltage: [600 Vac] [480 Vac] [240 Vac] [208 Vac] Maximum Design Voltage: 635 Vac Maximum Short-Circuit Current: 100 kair (@ 635 Vac) ANSI Type 2B rating Internal Arcing Short-Circuit Current: [100 Vac] [65 Vac] Arcing Duration: 500 msec Arc Resistant General Construction: Indoor NEMA 1 Enclosure Baffle Compartment Assembly [Plenum] Removable Rear Cover Panels Secured with Captive Screws [Hinged Doors] ArcBlok Technology Field-Interchangeable Micrologic Trip Units Schneider Electric Canada 5985 McLaughlin Road Mississauga, ON L5R 1B8 Tel: 1-800-565-6699 www.schneider-electric.com/ca Schneider Electric México Av. Javier Rojo Gómez 1121-A Col. Gpe. del Moral C.P. 09300 México D.F. Tel. 5804 5000 www.schneider-electric.com/mx May 2013 2013 Schneider Electric. All Rights Reserved. Schneider Electric, Power-Zone, ArcBlok, Masterpact, Micrologic, and Make the most of your energy are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. 998-1166437_US