Model Number Electrical Compatibility Module Connector Type. M250-60-2LL-S22 60 cell PV module MC-4 Type 2 Locking

Similar documents
Enphase M250 Microinverter

Engage Coupler. Engage Coupler Chase

Enphase Engage Cable and Accessories

Enphase M215 Microinverter

Enphase Microinverter Model M215

AC Module Installation Guide Content

Designing Multi-Tenant and Multi-Home Developments with Enphase Microinverters

Installation Guide Content for P250xV-240 microinverters

TECHNICAL BRIEF. Commercial PV in Australia and New Zealand Using the Enphase Microinverter System

Envoy Communications Gateway

AC Module Installation Guide Content

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Envoy Communications Gateway , Rev 05

Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance

Expedited Permit Process for PV Systems AC Module

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

User Manual. Replus-250 Replus-250A Replus-250B. U.S.A Add: 301 Howard St, Suite 850, San Francisco, CA T:

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Installation and Operations Manual. Siemens Microinverter Model SMIINV215R60XX

AC Unison Installation Guide

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

Safety and Installation Instructions for AC Modules

sunmax Residential Solar Solution sunmax Hardware sunmax Software

How To Install And Operate An Ecsecsys Power Supply

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Solar Panel Installations

Request for Proposals for Photovoltaic System Installation

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

CITY OF LOS ANGELES CALIFORNIA

Energy Communication Unit (ECU)

RESIDENTIAL PHOTOVOLTAIC SUBMITTAL REQUIREMENTS

Replacing Fuel With Solar Energy

Energy Communication Unit (ECU)

4KVA/5KVA Parallel Installation Guide

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

TruPower-Portable-500W. Solar Starter kit

Installation Guide Solar Connect-11

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

City of San Diego Residential Photovoltaic Systems Inspection Guidelines

How To Plan Out An Array Of Solar Panels

Solar monitoring gateway quick start guide

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Los Angeles Fire Department Requirement No. 96 SOLAR PHOTOVOLTAIC SYSTEM

Doe Residence kw DC Roof Mounted Photovoltaic System

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

User Manual of Grid Tie Inverter with Limiter

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

RAY-MAX Integrated Solar Power Strip

HP UPS R1500 Generation 3

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Submittal Requirements for Solar Photovoltaic Installations 10 kw or Less in One and Two Family (Duplex) Dwellings

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

AutoDome Easy II. VEZ Series. Mounting Manual

Solar Photovoltaic SPECIFICATION, CHECKLIST AND GUIDE. Renewable Energy Ready Home

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

Section III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS

LIEBERT VNSA Installation Sheet

Uninterruptible Power Supply

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Cable/Conduit Conversion

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Wireless Router Setup Manual

Solar Photovoltaic (PV) Systems

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

County of Riverside Building and Safety Department

E E V R E - R S - O S L O A L R

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

No Phone Line II-48 System

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

46120-F0 Solar Energy Training System

Protect your home and family with Advanced Technology from Cutler-Hammer

Extension Cord Safety Policy

AC and DC Drive System Installation Information

Distributing Power to Blade Servers

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Contractors Guide Central Inverter System Installation

HP R12000 and R18000 DirectFlow UPS User Guide

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

8 Ways Power Optimizers are Better by Design

Step 1: Application Instructions

Solar Kit. Complete solution to optimize your photovoltaic system

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Installation Guide. Sloped Roof Mounting System (60 Cell Modules) Version 2.5

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Transcription:

TECHNICAL BRIEF M250 Microinverter System Installation Planning The M250 Microinverter The Enphase M250 Microinverter is a powerful and efficient grid-tied microinverter. It is compatible with most 60-cell PV modules (to 300 Watts or higher) and installs quickly and easily. It works with both three-phase 208 VAC and single-phase 240 VAC services. A separate model is available for 230 VAC service in other regions. For detailed installation information, refer to the M250 Installation and Operations Manual or the M250 Quick Install Guide at http://www.enphase.com/support. Microinverter Compatibility The Enphase M250 is electrically compatible with all 60-cell modules. The PV module must also use PV (photovoltaic) Wire. To ensure mechanical compatibility, order PV modules with MC-4, Type 2 connectors. Model Number Electrical Compatibility Module Connector Type M250-60-2LL-S22 60 cell PV module MC-4 Type 2 Locking NOTE: Be sure to order the correct connector type for both microinverter and PV module from your distributor. As a rule, the electrically positive output of the PV module always connects to the positive input of the microinverter. However, PV modules come with a variety of labels. For more information, refer to Mating Microinverters with PV Modules for Correct Polarity at http://www.enphase.com/support. Branch Circuit Capacity Do not exceed the maximum number of microinverters in an AC branch circuit as listed in the following table. You must protect each microinverter AC branch circuit with a 20A maximum breaker. Maximum number of M250s per 20 amp AC Branch Circuit Service type Max M250s per AC branch 240V 16 208V 24 1

Installation Flow Every Enphase installation should include these basic steps. Plan to complete these steps in the order shown. 1. Register the System First-time installers: go to https://enlighten.enphaseenergy.com/users/new and complete the form. Your login credentials will be emailed to you. Existing installers and those with new credentials: Log into the Enphase Enlighten software. Click Add a New System in the Installation Status widget. 2. Install the Envoy Install the Envoy Communications Gateway as directed by the installation manual. Locate a dedicated AC outlet close to the load center. Place the Envoy so that its AC cord can reach this outlet. Plug the Envoy into the dedicated AC outlet and connect it to a broadband router. Wait for the Envoy to display "+Web". Allow 20 minutes in case a software upgrade is required. Do not unplug the Envoy during software upgrade! Set up the Grid Profile for your region, if required. 3. Install the PV Modules and the Enphase Microinverters Install the PV modules and microinverters as directed by the installation manuals. Use the Installer Toolkit to scan the microinverters. For more information, go to http://enphase.com/installer-toolkit/. As an alternative, you can manually build the map: Peel the removable serial number label from each microinverter and affix it to the respective location on the map. 4. Complete the Set Up Ensure at least 3 level bars and the correct number of microinverters are showing on the Envoy LCD screen. Once the Envoy has detected the microinverters, log in to Enlighten to use the Array Builder. For tips on how to use it, visit http://enphase.com/support/videos. 2

The Enphase Engage Cable The M250 has integrated DC and AC cables and connectors. The DC connectors attach to the PV module, while the AC connector attaches directly to the Engage Cable. No additional cabling is needed. The Engage Cable is a continuous length of 12 AWG, outdoor rated cable, with integrated connectors for microinverters. These connectors are preinstalled along the entire cable and spaced to accommodate either portrait and landscape PV module orientations. To install the cable, just roll out the desired length of cable and cut it to size. One end is wired directly into the junction box at the head of the branch circuit. The other end is sealed from the environment using an Engage Terminator. The M250 AC cable connectors are then plugged into the regularly spaced connectors as shown. The Engage Cable is available in two connector spacing options and two voltage types: 240 VAC and 208 VAC. To fit differing needs, the cabling is available in a variety of lengths. Connector Spacing Options The gap between connectors on the cable can be either 1.025 meters (40 ) or 1.7 meters (67 ). The 1.025 meter spacing is best suited for connecting PV modules installed in portrait mode, while the 1.7 meter gap is best suited to PV modules installed in landscape mode. 3

Voltage Types and Conductor Count The Engage Cable is available for either 240VAC split phase or 208VAC three phase (Separate models are available for 230 VAC service). All cable connectors bear labels indicating their cable voltage designation. Typically used for residential applications, 240VAC cabling includes four conductors. Threephase 208VAC cabling includes five conductors and is used for most commercial installations. Because Enphase microinverters output onto two phases, three phase cabling balances the phases by rotating the conductors from one microinverter to the next as shown in the following diagram. Cabling Length Options Engage Cabling is available in shorter lengths with 30 or 40 connectors, depending upon voltage type. Longer lengths can be ordered and cut to suit per order. Ordering options include: Model Number Voltage type/ conductor # Connector count Connector spacing PV module orientation Approx. weight ET10-240-40 ET17-240-40 ET10-208-30 ET17-208-30 ET10-240-BULK ET17-240-BULK ET10-208-BULK ET17-208-BULK 240VAC, 4 conductor 240VAC, 4 conductor 208VAC, 5 conductor 208VAC, 5 conductor 240VAC, 4 conductor 240VAC, 4 conductor 208VAC, 5 conductor 208VAC, 5 conductor 40 connectors 1.025 m (40 ) Portrait 18.1 kg (40 lbs) 40 connectors 1.7 m (67 ) Landscape 20.4 kg (45 lbs) 30 connectors 1.025 m (40 ) Portrait 13.6 kg (30 lbs) 30 connectors 1.7 m (67 ) Landscape 15.9 kg (35 lbs) 240 connectors 1.025 m (40 ) Portrait over 90 kg (200 lbs) 240 connectors 1.7 m (67 ) Landscape over 90 kg (200 lbs) 240 connectors 1.025 m (40 ) Portrait over 90 kg (200 lbs) 240 connectors 1.7 m (67 ) Landscape over 90 kg (200 lbs) 4

Planning for Cable Lengths and Type The Engage Cable is flexible enough to adapt to almost any solar design. To determine the length and cable type that you need, take into account the following considerations: Calculate the number of Enphase Microinverters to be installed on the AC branch. Be certain to allocate the correct number of connectors, including extra connectors for gaps and turns. Account for any additional length required to reach from the AC branch circuit junction box to the first microinverter. If greater than half a connector cable interval is needed, it may be necessary to include one (or more) unused connectors in order to span this distance. Unused connectors must be covered with Enphase sealing caps. Plan to minimize the number of unused connectors with three-phase systems. If cable connectors are left unused on a three-phase system, it creates a phase imbalance on the branch circuit. If multiple cable connectors are skipped over multiple branch circuits, the imbalance can multiply. You can avoid skipping Engage Cable connectors with the use of Engage Couplers. For instance, use the Engage Coupler to connect two Engage Cables or to connect Engage Cable to field cable. There are many possible scenarios for each type of connection, but they generally fall into four categories: Engage Cable to Engage Cable: 1. Make use of leftover lengths of Engage Cable 2. Transition between portrait and landscape Engage Cable Engage Cable to Field Cable (#12 TC-ER): 3. Transition between sub-arrays on the same circuit 4. Create wiring extensions for Engage Cable NOTE: The Engage Coupler only supports #12 TC-ER, which may not be sufficient for homerun wiring. Enphase Energy recommends maintaining less than 2% voltage drop across all wiring. In situations where you cannot use an Engage Coupler, you can use an electrical junction box to transition between cable types. You must account for all lengths of cable when calculating total VRise. Refer to the following documents (at http://www.enphase.com/support) for more information on the Engage Coupler and to maintain AC VRise at less than 2%: o Applications of the Engage Coupler o Circuit Calculations for the M250 Microinverter o Calculating AC Line Voltage Drop for M250 Microinverters with Engage Cables Plan for additional length to reach from one row of PV modules to the next. If the PV modules are laid out in multiple rows, plan for any additional cable needed to cover the distance from one row to the next. When planning cabling turns or loops, do not form loops smaller than 4.75 inches (12 cm). If needed, plan for multiple sub-arrays. The AC branch circuit may be composed of several smaller sub-arrays across more than one roof plane. In this case, cut the cable to service each smaller array, and connect the sub-arrays using appropriately rated runs of conduit. Accomplish the transition from cable to conduit by using an outdoor rated junction box, as required by the NEC and local code. You must cover unused connectors with Enphase sealing caps. Mixture of PV modules in both portrait and landscape installation. When PV modules are installed in mixed orientation (both portrait and landscape orientation), solutions include: 1. Using Engage Cable with 1.025 meter spacing between connectors results in cleanest install for the modules in portrait mode. For modules placed in landscape mode, plan for an unused 5

connector between each PV module to achieve the required additional distance. Unused connectors must be covered with Enphase watertight sealing caps. 2. Using Engage Cable with 1.7-meter spacing between connectors results in cleanest install for the modules in landscape mode, but requires that any additional cable length between PV modules in portrait mode be coiled and dressed so that cabling does not contact the roof. Again, unused connectors must be covered with Enphase sealing caps. 3. Another solution when PV modules are installed in mixed orientation is to transition between 1.025 and 1.7 meter spacing cable options using the Engage Coupler or an outdoor-rated junction box. This junction box can be installed to the PV racking. Refer to http://enphase.com/products/engage-coupler/ for information on the Engage Coupler. How it Fits Together In the following diagram, the M250 Microinverter and the Engage Cable are shown together with racking, grounding and PV modules. 6

Microinverter Installation Requirements Allow a minimum of 1.9 cm (0.75 inches) between the roof and the bottom of the microinverter. Allow 1.3 cm (0.50 inches) between the back of the PV module and the top of the microinverter. You must install the M250 under the module, out of rain and sun. Do not mount the microinverter in a position that allows long-term exposure to direct sunlight or in a vertical orientation that allows water to collect in the DC connector recess. Installing the microinverter black side up or vertically, with the DC connectors facing up, is not permitted. Racking Compatibility The M250 Microinverter and Engage Cabling are compatible with a variety of racking systems. For a list of approved PV racking types, refer to the Racking Compatibility document at http://www.enphase.com/support. Example Installation: Layout & Parts Needed, 208 VAC Commercial The following installation diagram shows an example with five branches. The 208V layout shows five center-fed branches with 24 microinverters each. The PV modules are in landscape orientation. Tables following the diagram list required and optional equipment. 7

Enphase Items Required Quantity Description Order Number 120 M250 Microinverter M250-60-2LL-S22 3 packs Cable clip (each pack contains 100 clips) ET-CLIP-100 1 pack Disconnect tool (each pack contains five tools) ET-DISC-05 1 pack Branch terminator (each pack contains 10 terminators) ET-TERM-10 1 1 pack 1 Engage Cable divided into ten lengths: Each length should be about 20.4 meters (67 feet) with 12 connectors. Watertight Sealing cap (each pack contains 10). Required only if there are any unused connectors; Unused connectors must be covered with this cap. Envoy Communications Gateway (monitors up to 600 microinverters) 1 Engage Coupler (each pack contains five Couplers). Used for splicing two AC power cables within an array. ET17-208-BULK ET-SEAL-10 ENV-120 ET-SPLK-05 Non-Enphase Items Required Quantity Description 120 60-cell PV module 5 Weather-proof (NEMA) junction box 5 Three-pole 20 amp circuit breaker 1 Three-pole 200 amp circuit breaker 1 200 amp load center 1 Lightning protection device (3-phase AC surge protector) Homerun conductors Torque wrench, sockets, wrenches for mounting hardware Adjustable wrench or open-ended wrench (for terminator caps) Inspection mirror (for viewing indicator lights on the undersides of the microinverters) 1 If installing a system of more than 600 microinverters, see the Commercial Design Guide at http://www.enphase.com/support. 8