1 Installation and Operations Manual Siemens Microinverter Model SMIINV215R60XX
2 Contact Information Siemens Industry, Inc. Infrastructure & Cities Sector Low and Medium Voltage 5400 Triangle Parkway Norcross, GA FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment. Other Information Product information is subject to change without notice. All trademarks are recognized as the property of their respective owners. For Siemens Microinverter Warranty Terms and Conditions, see the Appendix on page 28 of this manual Siemens Industry, Inc. All rights reserved. Page 2 Copyright 2011 Siemens Industry, Inc , Rev 01
3 Table of Contents Important Safety Information... 4 Read this First... 4 Symbol Legend... 4 Safety Instructions... 4 The Siemens Microinver System... 4 How the Microinverter Works... 6 System Monitoring... 6 Optimal Reliability... 6 Ease of Design... 6 Siemens Microinverter Installation... 7 Compatibility and Capacity... 7 Parts and Tools Required... 8 Lightning Surge Suppression... 8 Installation Procedure... 9 Step 1 Measure AC at Service Entrance Conductors... 9 Step 2 Install the AC Branch Circuit Junction Box Step 3 Position the Trunk and Drop Cabling Step 4 Attach the Microinverters to the Racking Step 5 Dress the Trunk and Drop Cable Step 7 Terminate the unused end of the Trunk and Drop Cable Step 8 Connect the Cable to Junction Box(es) Step 9 Ground the System Step 10 Complete the Installation Map Complete the Siemens Map Alternative: Create Your Own Map Step 11 Connect the PV Modules Step 12 Build the Virtual Array Commissioning and Operation Commissioning Operating Instructions Troubleshooting Status LED Indications and Error Reporting Startup LED Operation: Ground Fault Detection Indicator (GFDI) Fault: Other Faults: Troubleshooting an Inoperable Microinverter Disconnecting a Microinverter from the PV Module Installing a Replacement Microinverter Technical Data Technical Considerations Technical Specifications Siemens SMIINV215R60XX Microinverter Operating Parameters Appendix Limited Warranty Siemens Installation Map Sample Wiring Diagram SMIINV215R60XX, 240 Vac or 208 Vac Single Phase Sample Wiring Diagram SMIINV215R60XX, 208 Vac Page 3 Copyright 2011 Siemens Industry, Inc , Rev 01
4 Important Safety Information Read this First This manual contains important instructions for use during installation and maintenance of the Siemens SMIINV215R60XX Microinverter. Symbol Legend To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Siemens Microinverter, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. This indicates a situation where the present voltage could cause injury or death. Extreme caution is required when servicing or installing the equipment referenced. WARNING!! This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. NOTE: : This indicates information particularly important for optimal system operation. Follow instructions closely. Safety Instructions Perform all electrical installations in accordance with all local electrical codes and the National Electrical Code R (NEC), ANSI/NFPA 70. Be aware that only qualified personnel should install and/or replace Siemens Microinverters. Do not attempt to repair the Siemens Microinverter; it contains no user-serviceable serviceable parts. If it fails, please contact Siemens customer service to obtain an RMA number and start the replacement process. Tampering with or opening the Siemens Microinverter will void the warranty. Before installing or using the Siemens Microinverter, please read all instructions and cautionary markings in the technical description and on the Siemens Microinverter System and the Photovoltaic (PV) array. Connect the Siemens Microinverter to the electrical utility grid only after receiving prior approval from the utility company. Be aware that the body of the Siemens Microinverter is the heat sink and can reach a temperature of 80 C (176 F). To reduce risk of burns, do not touch. Do NOT disconnect the PV module from the Siemens Microinverter without first removing AC power. Disconnect AC power by disengaging the circuit breaker or disconnect before the first inverter connection. Page 4 Copyright 2011 Siemens Industry, Inc , Rev 01
5 The Siemens Microinverter System The Siemens Microinverter System is the world s most technologically advanced inverter system for use in utility-interactive applications. This manual details the safe installation and operation of the Siemens Microinverter. The three key elements of a Siemens Microinverter System are: the Siemens Microinverter the Envoy Communications Gateway the Enlighten web-based monitoring and analysis system This integrated system maximizes energy harvest, increases system reliability, and simplifies design, installation and management. Page 5 Copyright 2011 Siemens Industry, Inc , Rev 01
6 How the Microinverter Works The Siemens Microinverter maximizes energy production from your photovoltaic (PV) array. Each Siemens Microinverter is individually connected to one PV module in your array. This unique configuration means that an individual Maximum Power Point Tracker (MPPT) controls each PV module. This ensures that the maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array. That is, although individual PV modules in the array may be affected by shading, soiling, orientation, or module mismatch, the Siemens Microinverter insures top performance for its associated PV module. The result is maximum energy production from your PV system. System Monitoring Indoors, you can install the Envoy Communications Gateway by plugging it into any convenient 120Vac wall socket and providing an Ethernet connection to your broadband router or modem. After installation of the Envoy, the Siemens Microinverters automatically begin reporting to the Enlighten web server. The Enlighten software presents current and historical system performance trends, and it informs you when the PV system is not performing as expected. Optimal Reliability Microinverter systems are inherently more reliable than traditional inverters. The distributed nature of a microinverter system ensures that there is no single point of system failure in the PV system. Siemens Microinverters are designed to operate at full power at ambient temperatures as high as 65 C (150 F). The inverter housing is designed for outdoor installation and complies with the NEMA 6 environmental enclosure rating standard: NEMA 6 rating definition: Indoor or outdoor use primarily to provide a degree of protection against hose-directed water, and the entry of water during occasional temporary submersion at a limited depth, and damage from external ice formation. Ease of Design PV systems using Siemens Microinverters are very simple to design and install. You will not need string calculations, and you can install individual PV modules in any combination of module quantity, type, age and orientation. You won t need to install cumbersome centralized or string inverters. Each microinverter quickly mounts on the PV racking, directly beneath each PV module. Low voltage DC wires connect from the PV module directly to the co-located microinverter, eliminating the risk of personnel exposure to dangerous 600 Vdc power. Page 6 Copyright 2011 Siemens Industry, Inc , Rev 01
7 Siemens Microinverter Installation Follow the instructions in this section to install Siemens SMIINV215R60XX Microinverters. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Be aware that installation of this equipment includes risk of electric shock. Normally grounded conductors may be ungrounded and energized when a ground fault is indicated. WARNING: Before installing the Siemens Microinverter, read all instructions and cautionary markings in the user manual, on the Siemens Microinverter, and on the photovoltaic array. WARNING: Perform all electrical installations in accordance with all local electrical codes and the NEC R, ANSI/NFPA 70. WARNING: Connect the Siemens Microinverter to the electrical utility grid only after receiving prior approval from the utility company. WARNING: Be aware that only qualified personnel should connect the Siemens Microinverter to the electrical utility grid. Compatibility and Capacity The Siemens SMIINV215R60XX Microinverters are electrically compatible with most 60-cell PV modules. For more information, see Technical Data page 25 of this manual. Refer to the Siemens website ( for a list of electricallycompatible PV modules and approved PV module racking systems. To ensure mechanical compatibility, be sure to order the correct connector type for both microinverter and PV module from your distributor. Electrical Compatibility Model Number Works with PV Module Type Module Connector Type SMIINV215R60MC 60 cell MC-4 Type 2 Locking or Amphenol H4 Locking SMIINV215R60TY 60 cell Tyco Solarlock Locking Voltage and Capacity Maximum number of SMIINV215R60XXs per 20 amp AC Branch Circuit Service type Max SMIINV215R60XXs per branch Max PV modules per branch Single phase 240 V or 208 V Three phase 208 V Page 7 Copyright 2011 Siemens Industry, Inc , Rev 01
8 Parts and Tools Required In addition to the SMIINV215R60XX microinverters, PV modules, racking, and associated hardware, you will need the following items. Siemens equipment: Trunk and Drop cabling, as needed NOTE: Order the correct Trunk and Drop Cable type. Installers must order cable for either split phase 240 VAC, typical for residential applications, or three phase 208 VAC, typical for commercial installations. All drop connectors on the Trunk and Drop Cable bear labels indicating the cable voltage designation. Use split phase 240 VAC cable at sites with 208 single phase service. Grounding clips Drop connector seals, as needed (for any unused drops on Trunk and Drop Cabling) Terminator caps, as needed (for unused ends of Trunk and Drop Cabling) Trunk and Drop disconnect tool (a number 3 Phillips screwdriver can be substituted) Other items: Appropriate junction box Continuous grounding conductor, grounding washers Number 2 Phillips screwdriver Torque wrench, sockets, wrenches for mounting hardware Adjustable wrench or open-ended wrench (for terminator caps) Tool for PV module locking connectors Mechanics cs mirror (for viewing indicator lights on the undersides of the microinverters) Lightning Surge Suppression Lightning does not actually need to strike the equipment or building where the PV system is installed to cause damage. Often, a strike nearby will l induce voltage spikes in the electrical grid that can damage equipment. Siemens Microinverters have integral surge protection, greater than most traditional inverters. However, if the surge has sufficient energy, the protection built into the Microinverter can be exceeded, and the equipment can be damaged. As the Siemens Limited Warranty does not cover acts of God such as lightning strikes, and since lightning strikes can occur anywhere, it is best practice to install surge protection as part of any solar installation. We recommend the following protection devices. These have been tested to ensure that they do not interfere with power line communications. Install per vendor instructions. Vendor: Siemens, Part Number: TPS3 03 Application: : Residential 120/240V Split Phase where a Neutral to Ground (N-G) bond exists. Vendor: Siemens, Part Number: TPS3 12 Application: Commercial branch panel protection (See the vendor datasheet for these models at ). Page 8 Copyright 2011 Siemens Industry, Inc , Rev 01
9 Installation Procedure Installing the Siemens Microinverter System involves several key steps. Each step listed below is detailed in the following pages. Step 1 Measure VAC at Service Entrance Conductors Step 2 Install the AC Junction Box Step 3 Position the Trunk and Drop Cabling Step 4 Attach the Microinverters to the Racking Step 5 Dress the Trunk and Drop Cable Step 6 Connect the Microinverters Step 7 Terminate the unused end of the Trunk and Drop Cable Step 8 Connect the Cable to AC Junction Box(es) Step 9 Ground the System Step 10 Complete the Paper Map Step 11 Connect the PV Modules Step 12 Build the Virtual Array DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. DO NOT connect Siemens Microinverters to the utility grid until you have completed all of the installation procedures as described in the following sections. Step 1 Measure AC at Service Entrance Conductors Measure AC line voltage at the service entrance conductors to confirm AC service at the site. Acceptable ranges are shown in the following table. 120/240 VAC or 208Y/120 VAC Single Phase 208Y/120 VAC Three Phase L1 to L2 L1, L2 to neutral 211 to 264 Vac L1 to L2 to L3 106 to 132 Vac L1, L2, L3 to neutral 183 to 229 Vac 106 to 132 Vac Page 9 Copyright 2011 Siemens Industry, Inc , Rev 01
10 Step 2 Install the AC Branch Circuit Junction Box DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Do NOT exceed the maximum number of microinverters in an AC branch circuit as listed on page 27 of this manual. You must protect each microinverter AC branch circuit with a 20 A maximum breaker. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Size the AC wire gauge to account for voltage drop. All components of system wiring must be considered, including internal voltage drop within the length of Trunk and Drop cabling. WARNING! Only use electrical system components approved for wet locations. a. Size the AC wire gauge to account for voltage drop. Select the correct wire size based on the distance from the beginning of the microinverter AC branch circuit to the breaker in the load center. All components of system wiring must be considered, including internal voltage drop within the length of Trunk and Drop Cable. Typically, three wire sections and several wire terminations must be quantified. There is also some resistance associated with each circuit breaker. As all of these resistances are in series, they add together. Since the same current is flowing through each resistance, the total voltage drop is total current times the total resistance. For a single-phase system, the total resistance is equal to two times the one-way resistance. For a three-phase system, each of the three line currents and resistances must be calculated. Use the voltage drop charts at: to select the correct wire size. NEC 1 guidelines for voltage drop on feeder and branch circuit conductors will not be adequate for microinverter branch circuits that contain the maximum allowable microinverters. b. Install an appropriate junction box at a suitable location on the PV racking system. You can center feed the branch, or you can install the junction box at the end of a row of PV modules. c. Provide an AC connection from the junction box back to the utility interconnection using equipment and practices as required by the NEC R and local jurisdictions. 1 National Electrical Code is Registered Trademark of the National Fire Protection Association Page 10 Copyright 2011 Siemens Industry, Inc , Rev 01
11 Step 3 Position the Trunk and Drop Cabling The cabling is a continuous length of 12 AWG, outdoor rated cable with a connector for each microinverter placed each PV module width. The microinverters plug directly into the cable, and the cable is terminated into the junction box that feeds electricity back to the system AC disconnect. WARNING! Make sure you using the correct cable type. Installers must order Trunk and Drop Cable for either 240 VAC single phase, typical for residential applications, or 208 VAC three phase, typical for commercial installations. All drop connectors on the cable bear labels indicating the cable type. Installers can use 240 VAC cable at sites with 208 single phase service. a. Lay the Trunk and Drop cabling along the route it will travel, positioning the connectors so that they align with the PV modules. NOTE: Many modules have a central stiffening brace. In these cases, do not position the connector and microinverter at the exact center of the PV module. Instead position the drop connectors so that the connectors do not conflict with the braces b. Module widths vary by manufacturer. The connector cable spacing is designed for the widest PV modules compatible with Siemens Microinverters. If narrower modules are used, it may be necessary to account for excess cable by adding a loop of cable at suitable intervals. Page 11 Copyright 2011 Siemens Industry, Inc , Rev 01
12 Step 4 Attach the Microinverters to the Racking a. Mark the approximate centers of each PV module on the racking system. b. Evaluate the location of the microinverter with respect to the PV module junction box or any other obstructions. c. Ensure both that the microinverter does not interfere with the PV module frames or stiffening brace, and that the drop cable from the microinverter can easily reach the connector on the Trunk and Drop cable. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Do NOT exceed the maximum number of microinverters in an AC branch circuit as listed on page 27 of this manual. You must protect each microinverter AC branch circuit with a 20A maximum breaker. WARNING: : Allow a minimum of 1.9 cm (0.75 inches) between the roof and the bottom of the microinverter. Also allow 1.3 cm (0.50 inches) between the back of the PV module and the top of the inverter. Do not mount the microinverter in a location that allows longterm exposure to direct sunlight (i.e., it should be covered by the PV module). d. Ground the microinverters using either a continuous, unbroken grounding conductor or approved grounding washers. If using grounding washers (e.g., WEEB) to ground the microinverter chassis to the PV module racking, choose a grounding washer that is approved for the racking manufacturer. Install one grounding washer per microinverter. Torque the microinverter fasteners to the values below. 1/4 mounting hardware 45 lb-in minimum 5/16 mounting hardware 80 lb-in minimum NOTE: : Using a power screwdriver is not recommended due to risk of galling. Compatible grounding washer part numbers are included in the Racking Compatibility Application Note. Installation guidelines are included in the Grounding Washer Application Note. Refer to both documents at: e. With the silver side of the microinverter facing up and the black side facing down, mount one microinverter at each of these locations using suitable hardware. The indicator light on the underside of the microinverter will be facing the roof. Page 12 Copyright 2011 Siemens Industry, Inc , Rev 01
13 Step 5 Dress the Trunk and Drop Cable a. Attach the Trunk and Drop cabling to the rack using the recommended clips, or you may use tie wraps. The cable clips are designed so that the drop cable from the microinverter can also be dressed into the clip underneath the Trunk and Drop cable. NOTE: : There are two through-holes holes in the trunk connector. These are not for mounting, but are used to disconnect the connector. Keep these release holes clear and accessible. b. Dress any excess cabling in loops so that it does not contact the roof. Do not leave the cabling to rest on the roof. There are several ways to support the cable. One method is to place tie wraps or clips on either side of the Trunk and Drop Connector. Use one or two additional clips, tie wraps, or other support scheme to secure the cable between connectors. Page 13 Copyright 2011 Siemens Industry, Inc , Rev 01
14 Step 6 Connect the Microinverters a. Remove the temporary shipping cap from the Trunk and Drop Cable and connect the inverter. There are two latching mechanisms within the connectors. Listen for two clicks as the connectors engage. Ensure that both latching mechanisms have engaged. b. Repeat for all microinverters in the branch. c. Cover any unused connector with a sealing cap. Listen for two clicks as the connectors engage. Ensure that both latching mechanisms have engaged. Do not use the shipping cap to cover unused connectors. The shipping cap does not provide an adequate environmental seal. IP67-rated sealing caps are required for the system to be UL compliant and to protect against moisture ingress. NOTE: : Within the term IP67, IP indicates an Ingress Protection (IP) rating against dust and liquids. This specific rating of IP67 indicates that this connector protects against all dust particles and immersion in liquid. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Make sure protective IP67 sealing caps have been installed on all unused AC connectors. Unused AC connectors are live when the system is energized by the utility system. NOTE: : If you need to remove an IP67 sealing cap. You must use the Siemens disconnect tool or a #3 Phillips screwdriver. Sealing caps may not be reused. Page 14 Copyright 2011 Siemens Industry, Inc , Rev 01
15 Step 7 Terminate the unused end of the Trunk and Drop Cable You must terminate the far end of the Trunk and Drop cable. a. Remove 60mm (2.5 inches) of the outer jacket of the cable end. b. Take the screw-on gland portion of the cable terminator and run the cable end through it. c. Take the wire holder and run the cable end through it. d. Bend the individual wires back into the recesses in the wire holder so that they angle back toward the cable. e. Cut the individual wires so that no excess extends outside of the wire holder. The portion that angles back will need to extend enough to fit neatly into the 0.5 cm (0.2 in) slot in the wire holder and flush with the edge of the cap. f. Insert the wire holder into the cap, and screw the gland portion onto the cap. Ensure that the gland portion is rotating, not the cap. g. Hold the cap with an Siemens disconnect tool, or insert a #2 Phillips screwdriver. Hold the gland portion with a 24 mm (7/8 ) wrench. Tighten the gland portion until the ratcheting feature on the cap bottoms out. h. Attach the terminated cable end to the racking using a clip or tie wraps so that the Trunk and Drop Cable and terminator do not touch the roof. i. Ensure that all cabling is located underneath the PV module. Page 15 Copyright 2011 Siemens Industry, Inc , Rev 01
16 Step 8 Connect the Cable to Junction Box(es) a. Connect Trunk and Drop cable into the AC junction box using an appropriate gland or strain relief fitting. The trunk and drop cable requires a strain relief connector with an opening of 1.3 cm (0.5 inches) in diameter. b. Connect the TRUNK AND DROP cable into additional junction boxes as needed to transition to conduit between smaller sub-arrays. Refer to the wiring diagrams located in the Appendix of this manual for more information. NOTE: Wires are identified as follows: L1 is sheathed in Black, L2 is sheathed in red, L3 is sheathed in blue, Neutral is sheathed in white, and Ground is sheathed in green. The grounding wire is used to ground the microinverters. A WEEB or continuous ground is required in addition to this green grounding wire. 120/240 or 208Y/120 VAC SINGLE PHASE WIRING 208Y/120 VAC THREE PHASE WIRING Balanced 208 VAC three phase is accomplished by alternating phases between microinverters as shown: NOTE: : The green wire acts as equipment ground. A continuous Grounding Electrode Conductor (GEC) for system ground is also required as described in the next step. Page 16 Copyright 2011 Siemens Industry, Inc , Rev 01
17 Step 9 Ground the System If you are not using WEEB grounding washers to ground the microinverter chassis as described in step 4, follow the step below. Each Siemens Microinverter comes with a ground clip that can accommodate a 6-8 AWG conductor. NOTE: : The AC output neutral is not bonded to ground inside the microinverter. a. Route a continuous GEC through each of the microinverters to the NEC 2 -approved AC grounding electrode. b. You can ground the racking and module to this conductor using a crimp connection. An alternative method is to connect the microinverter to the grounded racking using a grounding washer approved for the racking. c. Torque the microinverter fasteners to the values below. 1/4 mounting hardware 45 lb-in minimum 5/16 mounting hardware 80 lb-in minimum NOTE: : Using a power screwdriver is not recommended due to risk of galling. 2 National Electrical Code is Registered Trademark of the National Fire Protection Association Page 17 Copyright 2011 Siemens Industry, Inc , Rev 01
18 Step 10 Complete the Installation Map The Siemens Installation Map is a diagrammatic representation of the physical location of each microinverter in your PV installation. The virtual array in Enlighten n is created from the map you create. Use the blank map in the Appendix to record microinverter placement for the system, or provide your own layout if a larger or more intricate installation map is required. Complete the Siemens Map a. Each Siemens Microinverter rter has a removable serial number label located on the mounting plate. Peel the removable serial number label from each Siemens Microinverter and affix it to the respective location on the Siemens installation map (see map in the Appendix). You can also download installation maps and examples from Remember to keep a copy of the installation map for your records. Alternative: Create Your Own Map a. Draw a top-down view of the array using the Array Map template (using either the grid on Side A or the freeform area on Side B). Make sure to leave enough room to place the serial number stickers. b. When installing the microinverters, remove the serial number labels located next to the DC input cables and place them in the correct order on your drawing of the system. Remember to keep a copy of the installation map for your records. Step 11 Connect the PV Modules NOTE: : Completely install all microinverters and all system inter-wiring connections prior to installing the PV modules. a. Mount the PV modules above the microinverters. Each microinverter comes with two sets of oppositely sexed multicontact connectors. b. Mate the microinverters and PV modules as required. Repeat for all remaining PV modules using one microinverter for each module. WARNING: The M215 should be paired only with a 60-cell PV module. Page 18 Copyright 2011 Siemens Industry, Inc , Rev 01
19 Step 12 Build the Virtual Array When the system is energized and all microinverters are detected by the Envoy Communications Gateway, you can create the virtual array in Enlighten from the Siemens map you created. Once the virtual array is built, Enlighten displays a graphic representation of the PV system. It also shows detailed current and historical performance information. Please go to for more information on the Enlighten web-based based monitoring and analysis. a. Scan the paper installation map and upload it to the Activation form online. b. Use Array Builder to create the virtual array in Enlighten. Use the Installation map created in step 10 as your reference. NOTE: Go to to view an Array Builder demo. c. If you do not already have an account, please go to and click Enlighten Login to register. Page 19 Copyright 2011 Siemens Industry, Inc , Rev 01
20 Commissioning and Operation WARNING: Be aware that only qualified personnel must connect the Siemens Microinverter to the electrical utility grid. WARNING: Ensure that all AC and DC wiring is correct. Ensure that none of the AC and DC wires are pinched or damaged. Ensure that all junction boxes are properly closed. WARNING: Connect the Siemens Microinverter to the electrical utility grid only after receiving prior approval from the utility company. NOTE: The Status LED of each microinverter will blink green six times to indicate normal start-up operation one minute after DC power is applied. Commissioning To commission the Siemens Microinverter PV system: 1. Turn ON the AC disconnect or circuit breaker on each microinverter AC branch circuit. 2. Turn ON the main utility-grid AC circuit breaker (if applicable). Your system will start producing power after a five-minute wait time. 3. The Siemens Microinverters will begin sending performance data over the power lines to the Envoy. The time required for all microinverters to report to the Envoy will vary with the number of microinverters in the system. The first units should be detected within 15 minutes but the entire system could take hours to detect. 4. The SMIINV215R60XX has field adjustable voltage and frequency trip points. If adjustments are required by your local utility, the installer can use the Envoy to Manage the Grid Profile after all microinverters have been detected. For more information on Envoy operation, refer to the Envoy Installation and Operation Manual at Operating Instructions The Siemens Microinverter is powered on when sufficient DC voltage from the module is applied. One minute after DC voltage is applied, the status LED blinks green six times indicating proper start up. You may need to use a mechanics mirror r to view indicator lights on the undersides of the microinverters. Page 20 Copyright 2011 Siemens Industry, Inc , Rev 01
21 Troubleshooting Adhere to all the safety measures described throughout this manual. Qualified personnel can use the following troubleshooting steps if the PV system does not operate correctly. WARNING: Do not attempt to repair the Siemens Microinverter; it contains no userserviceable parts. If it fails, please contact Siemens customer service to obtain an RMA number and start the replacement process. Status LED Indications and Error Reporting Startup LED Operation: One minute after DC power is first applied to the microinverter, six short green blinks indicate a successful microinverter startup sequence. Six short red blinks after DC power is first applied to the microinverter indicate a failure during microinverter startup. Post-Startup LED Indications: Use a mechanics mirror to view indicator lights on the undersides of the microinverters: Flashing Green Producing power and communicating with Envoy Flashing Orange Producing power and not communicating with Envoy Flashing Red Not producing power Solid Red GFDI Fault Ground Fault Detection Indicator (GFDI) Fault: A solid red status LED when DC power has been cycled indicates the microinverter has detected a ground fault error. The LED will remain red and the fault will continue to be reported by the Envoy until the error has been cleared. The condition should clear with operator intervention unless conditions causing the event have not been remedied or if the failure is permanent. Follow the instructions in the Envoy Communications Gateway Installation and Operation Manual to clear this condition. Or, for assistance, contact Siemens customer support at or at [email protected]. Other Faults: All other faults are reported to the Envoy. Refer to the Envoy Installation and Operation Manual for troubleshooting procedures. Page 21 Copyright 2011 Siemens Industry, Inc , Rev 01
22 Troubleshooting an Inoperable Microinverter WARNING: Be aware that only qualified personnel should troubleshoot the PV array or the Siemens Microinverter. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Always disconnect AC power before disconnecting the PV module wires from the Siemens Microinverter. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Never disconnect the DC wire connectors under load. Ensure that no current is flowing in the DC wires prior to disconnecting. An opaque covering may be used to cover the module prior to disconnecting the module. WARNING: The Siemens Microinverters are powered by DC power from the PV modules. Make sure you disconnect the DC connections and reconnect DC power to watch for the six short LED blinks one minute after DC is applied. To troubleshoot an inoperable microinverter, follow the steps in the order shown: 1. Check the connection to the utility grid and verify the utility voltage and frequency are within allowable ranges shown in the Technical Data section on page 25 of this manual. 2. Verify that AC line voltage at the service entrance conductors and at the junction box for each Siemens branch are within the ranges are shown in the following table: 120/240 VAC or 208Y/120 VAC Single Phase 208Y/120 VAC Three Phase L1 to L2 211 to 264 Vac L1 to L2 to L3 183 to 229 Vac L1 to neutral L2 to neutral 106 to 132 Vac L1 to neutral L2 to neutral L3 to neutral 106 to 132 Vac 3. Verify utility power is present at the inverter in question by removing AC, then DC power. Never disconnect the DC wires while the microinverter is producing power. Re-connect the DC module connectors. After one minute, watch for six short LED blinks. 4. Check the AC branch circuit interconnection harness between all the microinverters. Verify that each inverter is energized by the utility grid as described in the previous step. 5. Make sure that any upstream AC disconnects, as well as the dedicated circuitbreakers for each microinverter branch circuit, are functioning properly and are closed. 6. Verify the PV module DC voltage is within the allowable range shown in the Technical Data section on page 25 of this manual. 7. Check the DC connections between the microinverter and the PV module. 8. If the problem persists, please call Siemens customer support at or at Page 22 Copyright 2011 Siemens Industry, Inc , Rev 01
23 Disconnecting a Microinverter from the PV Module To ensure the microinverter is not disconnected from the PV modules under load, adhere to the following disconnection steps in the order shown: 1. Disconnect the AC by opening the branch circuit breaker. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Disconnect the Siemens Microinverter from the electrical utility grid prior to servicing. 2. Disconnect the first AC connector in the branch circuit. The Siemens Microinverter AC connectors are tool-removable only. To disconnect a microinverter from the Trunk and Drop Cable, insert the two large prongs of the disconnect tool (shown below) into the two holes in the drop connector. Rock the connector back and forth while pulling gently to disengage. If the disconnect tool is not available, insert a #3 Phillips screwdriver into one hole, and rock that side of the drop connector out. Then, insert the screwdriver into the other hole and pull the connector out entirely. 3. Cover the module with an opaque cover. 4. Using a DC current probe, verify there is no current flowing in the DC wires between the PV module and the microinverter. 5. Care should be taken when measuring DC currents due to the fact that most clampon meters must be zeroed first and tend to drift with time. 6. Disconnect the PV module DC wire connectors from the microinverter. 7. Remove the microinverter from the PV array racking. DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working on this equipment. Do not leave the drop connector uncovered for an extended period. If you do not plan to replace the microinverter immediately, you must cover any unused connector with a sealing cap. Listen for two clicks as the connectors engage. Ensure that both latching mechanisms have engaged. Note that the shipping cap does not provide an adequate environmental seal. IP67-rated sealing caps are required for the system to be UL compliant and to protect against moisture ingress. Page 23 Copyright 2011 Siemens Industry, Inc , Rev 01
24 Installing a Replacement Microinverter 1. With the silver side of the microinverter facing up and the black side facing down, attach the replacement microinverter to the PV module racking using hardware recommended by your module racking vendor. 2. If you are using grounding washers (e.g., WEEB) to ground the chassis of the microinverter, the old grounding washer should be discarded, and a new grounding washer must be used when installing the replacement microinverter. Torque the microinverter fasteners to the values below. 1/4 mounting hardware 45 lb-in minimum 5/16 mounting hardware 80 lb-in minimum NOTE: : Using a power screwdriver is not recommended due to risk of galling. 3. If you are using a grounding electrode conductor to ground the microinverter chassis, attach the grounding electrode conductor to the microinverter ground clamp. 4. Remove the sealing cap from the Trunk and Drop Cable and connect the inverter. There are two latching mechanisms within the connectors. Listen for two clicks as the connectors engage. Ensure that both latching mechanisms have engaged. 5. Mount the PV module above the microinverter. Each microinverter comes with two sets of oppositely sexed multi-contact connectors. 6. Mate the microinverters and PV modules as required. Repeat for all remaining PV modules using one microinverter for each module. 7. Energize the branch circuit breaker, and verify operation of the replacement microinverter by checking the indicator light on the underside of the microinverter. You may need a mechanics mirror to see the indicator light. 8. Initiate a device scan at the Envoy. To do this, press and hold the Menu button on Envoy for two seconds to bring up the Envoy menu on the LCD window. When the LCD window displays Enable Communication Check, release the Menu button. 9. Use Enlighten s Array Builder function to add the newly detected microinverter to the virtual array. Page 24 Copyright 2011 Siemens Industry, Inc , Rev 01
25 Technical Data Technical Considerations The Siemens SMIINV215R60XX Microinverters are designed to operate with most 60-cell PV modules. Be sure to verify the voltage and current specifications of your PV module match those of the microinverter. For more information, refer to the Siemens website ( for a list of compatible PV module racking systems and PV modules. WARNING: You must match the DC operating voltage range of the PV module with the allowable input voltage range of the Siemens Microinverter. WARNING: The maximum open circuit voltage of the PV module must not exceed the specified maximum input voltage of the Siemens Microinverter. The output voltage and current of the PV module depends on the quantity, size and temperature of the PV cells, as well as the solar insolation on each cell. The highest PV module output voltage occurs when the temperature of the cells is the lowest and the module is at open circuit (not operating). The maximum short circuit current rating of the module must be equal to or less than the maximum input DC short circuit current rating of the microinverter. A list of compatible PV modules is maintained on the Siemens website ( Page 25 Copyright 2011 Siemens Industry, Inc , Rev 01
26 Technical Specifications Siemens SMIINV215R60XX Microinverter Operating Parameters Topic Unit Min Typical Max DC Operating Parameters MPPT voltage range V Operating Range V Maximum DC input voltage V 45 Minimum / Maximum start voltage V Maximum DC input short circuit current A 15 Maximum DC input current A 10.5 Ground fault protection ma 1000 Maximum input source backfeed current to input source AC Operating Parameters Maximum AC output Power (-40 to 65 C) W 215 A 0 Output power factor Nominal AC output voltage range 240 Vac Vrms Vac Vrms Extended AC output voltage range 240 Vac Vrms Vac Vrms Maximum AC output current 240 Vac 208 Vac A A Nominal AC output frequency range Hz Extended AC output frequency range Hz Maximum AC output over current protection A 20 A Maximum AC output fault current & duration A peak, ms 25.2 A peak over 1.74 ms A RMS, Cycles High AC Voltage trip limit accuracy % ±2.5 Low AC Voltage Trip limit accuracy % ±4.0 Frequency trip limit accuracy Hz ±0.1 Trip time accuracy ms ± A RMS over 3 cycles 1.04 A RMS over 5 cycles Page 26 Copyright 2011 Siemens Industry, Inc , Rev 01
27 Siemens SMIINV215R60XX Microinverter Operating Parameters Topic Unit Min Typical Max Miscellaneous Operating Parameters Inverters per 20 amp AC branch circuit 240 Vac or 208 Vac Single Phase 208 Vac Three phase Peak inverter efficiency % 96.3 CEC weighted efficiency % 96.0 Static MPP tracking efficiency (weighted EN 50530) % 99.6 Total Harmonic Distortion % Ambient temperature range C Night Tare Loss mw 46 Storage temperature range C Dimensions not including mounting bracket (approximate) Features 17.3 cm x 16.4 cm x 2.5 cm (6.8 x 6.45 x 1.0 ) Weight 3.5 Lbs Enclosure environmental rating NEMA 6 Cooling Communication Standard warranty term Convective no fan Power line 25 years, limited Applicable Standards UL1741, IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, , and Integrated AC disconnect The AC connector has been evaluated and approved for use as the load-break disconnect required by the NEC 3. 3 National Electrical Code is Registered Trademark of the National Fire Protection Association Page 27 Copyright 2011 Siemens Industry, Inc , Rev 01
28 Appendix Limited Warranty Siemens Industry Inc. ("Siemens") has developed a highly reliable Microinverter that is designed to withstand normal operating conditions when used for its originally intended purpose in compliance with the Siemens User Manual supplied with the originally shipped system. The Siemens limited warranty ( Limited Warranty ) covers defects in workmanship and materials of the Siemens Microinverter ( Defective Product ) for a period of twenty-five (25) years from the date of original purchase of such Microinverter at point of sale to the originally-installed end user location (the "Warranty Period"). During the Warranty Period, the warranty is transferable to a different owner as long as the Microinverter remains installed at the originally-installed end user location. During the Warranty Period, Siemens will, at its option, repair or replace the Defective Product free of charge, provided that Siemens through inspection establishes the existence of a defect that is covered by the Limited Warranty. Siemens will, at its option, use new and/or reconditioned parts in repairing or replacing the Defective Product. Siemens reserves the right to use parts or products of original or improved design in the repair or replacement of Defective Product. If Siemens repairs or replaces a Defective Product, the Limited Warranty continues on the repaired or replacement product for the remainder of the original Warranty Period or ninety (90) days from the date of Siemens s return shipment of the repaired or replacement product, whichever is later. The Limited Warranty covers both parts and labor necessary to repair the Defective Product, but does not include labor costs related to un-installing the Defective Product or re-installing the repaired or replacement product. The Limited Warranty also covers the costs of shipping repaired or replacement product from Siemens, via a non-expedited freight carrier selected by Siemens, to locations within the United States (including Alaska and Hawaii) and Canada, but not to other locations outside the United States or Canada. The Limited Warranty does not cover, and Siemens will not be responsible for, shipping damage or damage caused by mishandling by the freight carrier and any such damage is the responsibility of the freight carrier. To obtain repair or replacement service under this Limited Warranty, the customer must comply with the following policy and procedure: All Defective Product must be returned with a Return Merchandise Authorization Number (RMA) which customer must request from Siemens. Before requesting the RMA, however, the customer should contact a Siemens technical support ( ) representative to evaluate and troubleshoot the problem while the Siemens Microinverter is in the field, since many problems can be solved in the field. If in-field troubleshooting does not solve the problem, Customer may request the RMA number, which request must include the following information: - Proof-of-purchase of the Defective Product in the form of (1) the dated purchase receipt from the original purchase of the product at point of sale to the end user, or (2) the dated dealer invoice or purchase receipt showing original equipment manufacturer (OEM) status, or (3) the dated invoice or purchase receipt showing the product exchanged under warranty. - Model number of the Defective Product - Serial number of the Defective Product - Detailed description of the defect - Shipping address for return of the repaired or replacement product All Defective Product authorized for return must be returned in the original shipping container or other packaging that is equally protective of the product Page 28 Copyright 2011 Siemens Industry, Inc , Rev 01
29 The returned Defective Product must not have been disassembled or modified without the prior written authorization of Siemens Siemens Microinverters are designed to withstand normal operating conditions and typical wear and tear when used for their original intent and in compliance with the installation and operating instructions supplied with the original equipment. The Limited Warranty does not apply to, and Siemens will not be responsible for, any defect in or damage to any Siemens Microinverter: (1) that has been misused, neglected, tampered with, altered, or otherwise damaged, either internally or externally; (2) that has been improperly installed, operated, handled or used, including use under conditions for which the product was not designed, use in an unsuitable environment, or use in a manner contrary to the Siemens User Manual or applicable laws or regulations; (3) that has been subjected to fire, water, generalized corrosion, biological infestations, acts of God, or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the Siemens Microinverter specifications, including high input voltage from generators or lightning strikes; (4) that has been subjected to incidental or consequential damage caused by defects of other components of the solar system; or (5) if the original identification markings (including trademark or serial number) of such Microinverter have been defaced, altered, or removed. The Limited Warranty does not cover costs related to the removal, installation or troubleshooting of the customer's electrical systems. The Limited Warranty does not extend beyond the original cost of the Siemens Microinverter. THE LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY SIEMENS AND, WHERE PERMITTED BY LAW, IS MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF TITLE, QUALITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OR WARRANTIES AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION. IN NO EVENT WILL SIEMENS BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, COSTS OR EXPENSES HOWEVER ARISING, WHETHER IN CONTRACT OR TORT, INCLUDING WITHOUT LIMITATION ANY ECONOMIC LOSSES OF ANY KIND, ANY LOSS OR DAMAGE TO PROPERTY, OR ANY PERSONAL INJURY. To the extent any implied warranties are required under applicable law to apply to the Siemens Microinverter, such implied warranties shall be limited in duration to the Warranty Period, to the extent permitted by applicable law. Some states and provinces do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential damages, so the above limitation(s) or exclusion(s) may not apply. This Limited Warranty gives the customer specific legal rights, and the customer may have other rights that may vary from state to state or province to province. Page 29 Copyright 2011 Siemens Industry, Inc , Rev 01
30 Siemens Installation Map Page 30 Copyright 2011 Siemens Industry, Inc , Rev 01
31 Sample Wiring Diagram SMIINV215R60XX, 240 Vac or 208 Vac Single Phase Page 31 Copyright 2011 Siemens Industry, Inc , Rev 01
32 Sample Wiring Diagram SMIINV215R60XX, 208 Vac Page 32 Copyright 2011 Siemens Industry, Inc , Rev 01
33
34 Siemens Industry, Inc. Infrastructure & Cities Sector Low and Medium Voltage 5400 Triangle Parkway Norcross, GA
Enphase Microinverter Model M215
INSTALLATION AND OPERATION MANUAL Enphase Microinverter Model M215 (M215-60-230) 141-00017, Rev 02c Corporate Headquarters Contact Information Enphase Energy Inc. 1420 N. McDowell Blvd. Petaluma, CA 94954
Enphase M215 Microinverter
INSTALLATION AND OPERATION MANUAL Enphase M215 Microinverter 141-00012, Rev 06 Contact Information Enphase Energy Inc. 1420 N. McDowell Blvd. Petaluma, CA 94954 http://www.enphase.com [email protected]
Enphase M250 Microinverter
INSTALLATION AND OPERATION MANUAL Enphase M250 Microinverter with integrated ground no GEC required 141-00022, Rev 01 Contact Information Enphase Energy Inc. 1420 N. McDowell Blvd. Petaluma, CA 94954 http://www.enphase.com
Model Number Electrical Compatibility Module Connector Type. M250-60-2LL-S22 60 cell PV module MC-4 Type 2 Locking
TECHNICAL BRIEF M250 Microinverter System Installation Planning The M250 Microinverter The Enphase M250 Microinverter is a powerful and efficient grid-tied microinverter. It is compatible with most 60-cell
User Manual. Replus-250 Replus-250A Replus-250B. U.S.A Add: 301 Howard St, Suite 850, San Francisco, CA 94105. T: +1 415 852 7418
User Manual Replus-250 Replus-250A Replus-250B U.S.A Add: 301 Howard St, Suite 850, San Francisco, CA 94105. T: +1 415 852 7418 Australia Add: 18 Corporate Blvd. Bayswater, VIC 3153, Australia T: +61 481
Enphase Engage Cable and Accessories
INSTALLATION MANUAL Enphase Engage Cable and Accessories 141-00016, Rev 03 Corporate Headquarters Contact Information Enphase Energy Inc. 1420 N. McDowell Blvd. Petaluma, CA 94954 USA Phone: +1 707-763-4784
Installation Guide Content for P250xV-240 microinverters
A C M o d u l e Installation Guide Content for P250xV-240 microinverters May 15, 2012 2011-2012 SolarBridge Technologies, Inc. All Rights Reserved. No part of this publication may be reused in any manner
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
YSmart Technology Co.,Ltd
YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,
AC Module Installation Guide Content
AC Module Installation Guide Content for ET-P660250AC May 9, 2012 2011-2012 ET Solar Group All Rights Reserved. No part of this publication may be reused in any manner nor in any form or format without
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Mini Power Bank and Charger
Mini Power Bank and Charger Owner s Manual Please read before using this equipment. Your charger is ETL listed to UL standards and meets all applicable FCC standards. WARNING: To reduce the risk of fire
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
WARRANTY CERTIFICATE
Effective Date WARRANTY CERTIFICATE EXTENDED LIMITED WARRANTY APsystems YC250, YC500 & YC1000 Microinverter Extension to 25 Years All APsystems YC250, YC500 & YC1000 Microinverters are covered by a 10
Installation and Operations Manual. Siemens VersiCharge. 1 2014 Siemens Industry, Inc. 813776
Installation and Operations Manual Siemens VersiCharge 1 2014 Siemens Industry, Inc. 813776 Contact Information Siemens Industry, Inc. Infrastructure & Cities Sector Low and Medium Voltage 5400 Triangle
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
AGS. Owner's Manual. Xantrex Automatic Generator Start Control System
AGS Owner's Manual Xantrex Automatic Generator Start Control System TABLE OF CONTENTS INTRODUCTION...3 Main Features...3 Safety Summary...3 THINGS YOU SHOULD KNOW...4 THEORY OF OPERATION...5 System...5
AC Module Installation Guide Content
AC Module Installation Guide Content for ET-P660250AC May 9, 2012 2011-2012 ET Solar Group All Rights Reserved. No part of this publication may be reused in any manner nor in any form or format without
User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.
DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
7 High-Resolution Digital Photo Frame
TM 16-1003 User s Guide 7 High-Resolution Digital Photo Frame One demo photo included, as illustrated Please read this user s guide before using your new photo frame. Package contents Photo Frame AC Adapter
User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual RK-2d / RK-2t 1U Short Depth Keyboard Drawer Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October
ADSL Modem Installation Guide. Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000. ADSL Modem Installation Guide
ADSL Modem Installation Guide Model # 36R515 Part # 030-300108 Rev. D Revision Date 12/2000 ADSL Modem Installation Guide Installation Instructions Westell ADSL Modem 1. Package Inspection and Contents...2
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
Residential Gateway (RG) Battery Backup REV B
Residential Gateway (RG) Battery Backup REV B Save this user manual This manual contains important instructions regarding the installation and operation of this device. Read this manual thoroughly before
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
Laser Wireless Rechargeable Mouse. User s Manual
Laser Wireless Rechargeable Mouse Model #: LM8000WR User s Manual Rev. 060801 User s Record: To provide quality customer service and technical support, it is suggested that you keep the following information
2GB MP3 Player USER GUIDE
DO NOT FORMAT UNIT under FAT. 2GB MP3 Player USER GUIDE Jazwares, Inc. 2010 CONTENTS Please read the instructions along with the MP3 Player carefully before you use it, so that you can operate it conveniently.
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions
USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE AeroVironment EV Solutions 2013 AeroVironment, Inc. All rights reserved. AeroVironment, EV Solutions, and the AeroVironment logo are trademarks
Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers
9229 Waterford Centre Dr. Bldg C, Suite 110 Austin, Tx 78758 Application Bulletin 103 - NEC Reference Guide for SolarBridge-Enabled AC Module Installers Current Version: 13 AC Modules are a new product
LED Security Spotlight User Manual
MOT ION-TR ACKING LED Security Spotlight User Manual www.jascoproducts.com 1-800-654-8483 2 TABLE OF CONTENTS Parts List 3 Questions? Missing Parts? 4 Installation (Wall mount) 6-9 Installation (Eave mount)
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
USB 2.0 4-Port Hub with USB Power Cable. User s Manual
USB 2.0 4-Port Hub with USB Power Cable Model: UH2500 User s Manual 251104-109159 Rev. 061107 User s Record: To provide quality customer service and technical support, it is suggested that you keep the
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL
WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL CAUTION: This system is not for use with antenna in raised position while
XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free 1 866 295 6775. www.powerbright.com
WARNING: This Unit employs Components that tend to produce arcs or sparks To prevent fire or explosion, do not install in compartments containing batteries or flammable materials - SHOCK HAZARD. DO NOT
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
2013 VTech Printed in China 91-009656-000 US
Rechargeable Power Pack User s Manual 2013 VTech Printed in China 91-009656-000 US INTRODUCTION The Rechargeable Power Pack makes it easier than ever to keep the InnoTab 3 or InnoTab 3S charged and ready
InnoMedia ESBC 9580-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9580-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
Universal Laptop Charger
USER GUIDE Universal Laptop Charger NS-PWLC591/NS-PWLC591-C Before using your new product, please read these instructions to prevent any damage. NS-PWLC591/NS-PWLC591-C Insignia NS-PWLC591/ NS-PWLC591-C
user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4
user s manual model #: SPB3200 Charger for Samsung Galaxy S 4 What s Included Unpack the battery case and make sure all accessories are put aside so they will not be lost. hello. USB to Micro USB Cable
Alarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2012 CONTENTS Please read the instructions along with the Alarm Clock carefully before you use it, so that you can operate it conveniently. WELCOME & Warnings Page
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
Canopy Surge. User Manual
Canopy Surge Suppressor User Manual SS00-UM-en Issue 2 May 2003 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Notices Safety Precautions: Before beginning your installation, please read
Optical Wireless Mouse. User s Manual
Optical Wireless Mouse Model : OM4000W User s Manual 110935-109154 Rev. 061101 User s Record: To provide quality customer service and technical support, it is suggested that you keep the following information
ALPHA Meter Installation Information
October 006 IL4-400Q ALPHA Meter Installation Information General This instructional leaflet contains general installation instructions for the following single phase and polyphase watthour meters: socket-connected
Bubble King. User Manual
Bubble King User Manual TABLE OF CONTENTS 1. Before You Begin... 3 What Is Included... 3 Unpacking Instructions... 3 Claims... 3 Text Conventions... 3 Icons... 3 Document Information... 3 Product at a
READ FIRST! Universal Car/Air Adapter User Manual
AutoAir Manual 1/9/03 2:03 PM Page 1 READ FIRST! Universal Car/Air Adapter User Manual Congratulations! Your new Kensington Universal Car/Air Adapter is a highly efficient Universal Car/Air Adapter for
DELORME. Getting Started with. Earthmate GPS BT-20. Bluetooth
DELORME Getting Started with GPS BT-20 Bluetooth Earthmate Table of Contents Overview... 2 Hardware Features... 2 Using the Earthmate GPS BT-20... 3 Charging the Battery... 4 Troubleshooting... 4 Hardware
PCI Express USB 2.0 Adapter Card
PEXUSB400 Instruction Manual PCI Express USB 2.0 Adapter Card 4-Port (Independent) PCI Express to High Speed USB 2.0 Adapter Card FCC Compliance Statement This equipment has been tested and found to comply
Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL
Wolverine 35mm Film to Digital Converter Model F2D USER MANUAL Version 1.01 December 2008 TABLE OF CONTENTS DESCRIPTION PAGE Table of Contents 1 Before Using the F2D Converter 3 FCC Certifications 3 Warning
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT. Perfect for ANDROID TM
GET CONNECTED Installation & Operation Manual HANDS-FREE BLUETOOTH MEDIA INTEGRATION KIT TranzIt BLU HF ISFM2351 Perfect for ANDROID TM Note to Readers, The information contained within the following documentation
2.5/3.5 SATA HDD Docking Station
SATADOCKU2 SATADOCKU2E SATADOCK22UE 2.5/3.5 SATA HDD Docking Station FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions Table of Contents Before Installing 2 GPS Fundamentals 3 Checking the Contents of the
Zolt Laptop Charger Plus User Guide
Zolt Laptop Charger Plus User Guide 70W Universal Laptop and Mobile Device Charger 1 Meet your Zolt Laptop Charger Plus The Zolt Laptop Charger Plus is a compact, lightweight, multi-device charger that
Co-location Interconnect Power Panel (CIPP) Installation Guide
Co-location Interconnect Power Panel (CIPP) Installation Guide Document INS-97xxxxxxx This guide covers the following part numbers- Trimm 97xxxxxxx Series Table of Contents Section 1 - General Information...
Dual-Cool Notebook Cooler Pad. User s Manual
Dual-Cool Notebook Cooler Pad Model #: CF4500U User s Manual Rev. 060801 User s Record: To provide quality customer service and technical support, it is suggested that you keep the following information
PV System Disconnect PV System Discon-
PV System Disconnect PV System Discon- INSTALLATION & OPERATION MANUAL 97-600100-06-A02 Preface PV Powered PV Powered designs, manufactures, and markets the solar power industry s most reliable photovoltaic
QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000
QUICK INSTALLATION 8-Port Telephony Gateway Model: SPA8000 Table of Contents Connect................................................. 4 Regulatory Information....................................12 WEEE
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
AVerMedia AVerKey imicro User s Manual
FCC NOTICE This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
Model 70A00-1. GSM Cellular Communications Center
Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2
egate INVOLAR Grid-Connected Photovoltaic Power Interface Model Number PIU4KA-230-UK User Operating Manual (Version_eGate(UK)G83_PIU4KA_1.
INVOLAR Micro-Inverters egate INVOLAR Grid-Connected Photovoltaic Power Interface Model Number PIU4KA-230-UK User Operating Manual (Version_eGate(UK)G83_PIU4KA_1.5) This manual is an integral part of the
TRANSFORMER 1-855-HD-HAMPTON HAMPTONBAY.COM
Item #1001 509 794 Model DIY-300PS USE AND CARE GUIDE TRANSFORMER Questions, problems, missing parts? Before returning to the store, call HamptonBay Customer Service 8 a.m. - 7 p.m., EST, Monday Friday,
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
Alarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2010 1 CONTENTS Please read the instructions along with the alarm clock carefully before you use it, so that you can operate it conveniently. WELCOME, Safety Tips
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions
u-traq autopro GPS Vehicle Tracking System Product # 1020-PRO User s Guide Installation and Operating Instructions Before Installing Table of Contents Before Installing 2 GPS Fundamentals 3 Checking the
Weather Radio Alarm Clock
1200093 User s Guide Weather Radio Alarm Clock Thank you for purchasing your Weather Radio Alarm Clock from RadioShack. Please read this user s guide before installing, setting up, and using your new weather
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.
Sense Components Sense monitor Antenna assembly External mounting kit Current sensors Download the Sense app. Go to sense.com/app Power cable Technical Specifications Sense is a home energy monitoring
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P
Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P Distributed in the U.S.A. and Canada by CHENG USA, INC. Sales (574) 294-8997 Warranty Service (877) 294-8997
PCI Express USB 3.0 Controller Adapter Card
PEXUSB3S2 Instruction Manual PCI Express USB 3.0 Controller Adapter Card 2-Port PCI Express SuperSpeed USB 3.0 Controller Adapter Card FCC Compliance Statement This equipment has been tested and found
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
InnoMedia ESBC 9380-4B. Quick Install Guide. www.innomedia.com 1
InnoMedia ESBC 9380-4B Quick Install Guide www.innomedia.com 1 Table of Contents Introduction 2 Package Contents 2 CAUTION 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED
Verbatim PowerBay Single USB and esata External Hard Drive Version 1.00
Verbatim PowerBay Single USB and esata External Hard Drive Version 1.00 User Manual Table of Contents Introduction... 2 Controls, Connectors and Indicators... 2 About the Hard Drive... 2 Locating the Drive
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance
WHITE PAPER Enphase Microinverters and Ungrounded Renewable Energy Systems: Canadian Electrical Code Compliance Overview Enphase has developed a new microinverter family that includes the M250 and new
Installation & Operation Manual
GET CONNECTED Installation & Operation Manual DEVICE INTEGRATION AND CHARGING KIT TranzIt USB IS32 Note to Readers, The information contained within the following documentation is subject to change without
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
ExpressCard USB 3.0 Controller Adapter Card
ECUSB3S2 Instruction Manual ExpressCard USB 3.0 Controller Adapter Card 2-Port ExpressCard SuperSpeed USB 3.0 Controller Adapter Card FCC Compliance Statement This equipment has been tested and found to
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
PathMak. Owner's Manual. Xantrex. athmaker Automatic Battery Switch
PathMaker Owner's Manual Xantrex PathMak athmaker Automatic Battery Switch 2 The Easy-to-Install Automatic Battery Switch For Marine, RV, Alternative Energy and Car Audio use Pick the unit that s right
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual
Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual 255379 Rev. D0 1015 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification
User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply
User Manual English APC Smart-UPS SC 1000/1500 VA 110/120/230 Vac 2U Tower/Rack-Mount Uninterruptible Power Supply 990-1851C, 10/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed