ControlNet Standard and High-flex Coax Cable



Similar documents
Hard Disk Drive (HDD)

Fiber Optic Cable Installation

Universal Serial Bus (USB) to DH-485 Interface Converter

Stratix 5700 Network Address Translation. Quick Start

CompactLogix Power Supplies Specifications

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

USB-to-Data Highway Plus Cable

MicroLogix 1100 Embedded Web Server

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

User Manual. DeviceNet Network Configuration

Logix5000 Controllers Nonvolatile Memory Card

Reference Manual. Pressure/Temperature Compensated Flow (P_PTComp) Version 3.1

RSLogix Guard PLUS! Programming Software

PowerFlex Dynamic Braking Resistor Calculator

ControlNet Fiber Media Planning and Installation Guide

Logix5000 Controllers Security

Stratix 5700 Switch Configuration

Installation Instructions. Before Installation. Read these installation instructions carefully before commissioning the pressure transmitter.

Product Compatibility and Download Center

1756 ControlLogix Chassis Specifications

Compact I/O End Caps/Terminators

Logix5000 Controllers Import/Export Project Components

Time Recorder Extension Module for the Dynamix 2500 Data Collector

BroadBand PowerShield. User Manual

Application Technique. Safety Function: Magnetic Door Switch Monitoring

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

Cloning Utility for VersaView Industrial Computers

Logix5000 Controllers Function Block Diagram

TECHNICAL NOTE 7-1. ARCNET Cable Length vs. Number of Nodes for the HYC9088 in Coaxial Bus Topology By: Daniel Kilcourse May 1991.

MicroLogix 1400 Embedded Web Server

1788 Linking Device Specifications

Logix5000 Controllers Nonvolatile Memory Card

Logix5000 Controllers Import/Export Project Components Programming Manual. Programming Manual

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Micro800 Programmable Controllers: Getting Started with CIP Client Messaging

Programming Manual Catalog Numbers 1756 ControlLogix, 1769 CompactLogix, 1789 SoftLogix, 1794 FlexLogix, PowerFlex 700S with DriveLogix

Legacy PanelView to PanelView Plus 6 Catalog Number Conversions

ControlNet Coax Media Planning and Installation Guide. Catalog Number 1786-series Installation Instructions

ET plus Antenna Amplifier 03/20/06

1756 ControlLogix Integrated Motion Modules Specifications

Encompass Program. The Benefits of Partnering with Rockwell Automation. Encompass Program Participation Levels

Logix5000 Controllers Security

Cloning Utility for Rockwell Automation Industrial Computers

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Backup Scanner Module

Digital Link Cross Connect (DLx ) System User Manual

ControlLogix Remote I/O Communication Module

User Guide. HDMI Active Cable Extender. DVI-7370c

Installation Guide. FactoryTalk Batch Material Manager Installation Guide

FactoryTalk ViewPoint Quick Start Guide

Architect/Contractor Information Package

L5354 ControlNet Communications Interface

How To Size A Stenner Pump

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Installation Guide Smart-UPS X External Battery Pack SMX120BP

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

FriendlyNet PC Card for PowerBook computers

DISCRETE SEMICONDUCTORS DATA SHEET M3D848. CGD MHz, 20 db gain power doubler amplifier. Product specification 2002 Oct 08

TRANSLATOR INSTALLATION AND OPERATIONS MANUAL KEYBOARD AND MOUSE CONVERTER Stancliff Road Phone: (281)

Allen-Bradley/Rockwell

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Safety Function: Door Monitoring

How To Install A Power Supply (Uplast) With A Battery Pack

USER MANUAL VS92A / VS94A / VS98A

HP 8970B Option 020. Service Manual Supplement

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

Drive Software Wizards Version 3.4

Current Probes. User Manual

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Allen-Bradley/Rockwell

Bimetallic Overload Relay Specifications

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

INSTRUCTION MANUAL MODEL PCD-88

YSmart Technology Co.,Ltd

User Manual. ControlNet Network Configuration

1701/22 FieldMonitor Management Interface Module

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

User Manual. Motion Analyzer Software Version 7.00

1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S

Installation. Basic Rack Power Distribution Unit AP9559

TTL to RS232 Adapter User Guide

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SKY LF: GHz Two-Way, 0 Degrees Power Divider

DeltaV SISnet Repeater

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

DDP-3 Engineering Guide

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

Laptop Power Adapter for home/office User Manual

WIRELESS STATUS MONITOR

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Usage, Installation, Warranty and Service Information

Allen-Bradley. User Manual. PanelView 1200/1400e Transfer Utility. (Cat. No. 2711E ND7)

Transcription:

Installation Instructions ControlNet Standard and High-flex Coax Cable Catalog Number 1786-RG6/A and 1786-RG6F/B About This Document This document contains application information you need to consider when you install standard RG-6 (1786-RG6/A) and high-flex RG-6 (1786-RG6F/A) coax cable in your ControlNet network. for information about this topic: see page: Determining Trunk-cable Section Lengths 3 About Cable Attenuation 4 Installing ControlNet Cable 7 Cable Specifications 7

2 ControlNet Standard and High-flex Coax Cable ControlNet is a trademark of ControlNet International. Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.ab.com/manuals/gi) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc. is prohibited. Throughout this manual we use notes to make you aware of safety considerations. WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. IMPORTANT ATTENTION SHOCK HAZARD Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you: identify a hazard avoid a hazard recognize the consequence Labels may be located on or inside the drive to alert people that dangerous voltage may be present. BURN HAZARD Labels may be located on or inside the drive to alert people that surfaces may be dangerous temperatures.

ControlNet Standard and High-flex Coax Cable 3 Determining Trunk-cable Section Lengths A ControlNet segment is comprised of one or more sections of trunk cable separated by s and terminated at both ends. The total cable length of a segment is equal to the sum of all the trunk-cable sections. trunk-cable section trunk-cable section 20162-M IMPORTANT When determining the cable length of trunk-cable sections, make sure you measure the actual cable path as it is routed in your network. Consider vertical dimensions as well as horizontal dimensions. You should always calculate the three-dimensional routing path distance when determining cable lengths. TIP Because high-flex RG-6 cable (1786-RG6F) has higher attenuation than standard RG-6 cable, a segment s total distance is reduced when you use high-flex RG-6F cable. Since the amount of high-flex RG-6F cable you can use in a system is less than the amount of standard RG-6 cable, you should keep high-flex cable use to a minimum. Use TNC or BNC bullet connectors to isolate areas that require high-flex RG-6F cable from areas that require standard RG-6 cable; this lets you replace the high-flex RG-6 section before flexure life is exceeded.

4 ControlNet Standard and High-flex Coax Cable The following tables and examples are provided to help you determine the lengths of cable you can use in your system. if you are using standard RG-6 cable (1786-RG6/A with attenuation of 5.99 db) The total allowable length of a segment depends on the number of s in your segment (there is no minimum trunk-cable section length requirement). The maximum allowable total length of a segment is 1,000 m (3,280 ft) with two s connected. Each additional decreases the maximum length of the segment by 16.3 m (53 ft). The maximum number of s allowed on a segment is 48 with a maximum length of 250 m (820 ft). maximum allowable segment length = 1000 m (3280 ft) - [16.3 m (53.4 ft) x [number of s - 2]] any RG-6 or RG-6F cable (1786-RG6F/A) a combination of RG-6 and RG-6F cable number of s in your segment and length of any RG-6 cable. maximum allowable segment length = (20.29 db - total s in segment X.32 db) X 1000 ft (304 m) cable attenuation 1 @ 10 MHz per 1000 ft (304 m) number of s in your segment and length of any RG-6 cable. (Attenuation 1786-R6F per 1000 ft @ 10 MHz/Attenuation 1786-RG6 per 1000 ft @ 10MHz) * length of 1786RG6F = equivalent length in 1786-RG6 cable. 1 Cable attenuation is defined as the signal loss as measured at 10MHz per 1000 ft (304.8 m) of cable. See Table 1 for cable attenuation for RG-6 and RG-6F cables. About Cable Attenuation See Table 1 for attenuation for RG-6 and RG-6F cables. Table 1 Attenuation for RG-6 and RG-6F cables cable type attenuation at 10 MHz per 1000 ft (304 m) 1786-RG6/A 1786-RG6F/A 5.99 db 13.5 db

ControlNet Standard and High-flex Coax Cable 5 You can increase the total trunk-cable length or number of s by installing repeaters on the segment. This creates another segment. The following examples explain how you can calculate allowable lengths of segments for standard RG-6 (1786-RG6/A), and high flex RG-6 (1786-RG6F/A) cable, as well as for a system that combines the two types of cables. EXAMPLE Example 1: Using only standard RG-6 cable in your system In this example, the segment: has 3 nodes (requires 3 s) uses standard 1786-RG6 cable To calculate the allowable cable length of standard 1786-RG6/A cable: 3280 ft - (53.4 ft * [3-2]) = maximum length 3280 ft - 53.4 ft = 3226.6 ft (983.4 m) 1786-RG6 cable 2570.4 ft (783.4 m) 656.2 ft (200 m) 20162-M EXAMPLE Example 2: Using only RG-6F cable in your system In this example, the segment: has 16 nodes (requires 16 s) uses high-flex 1786-RG6F cable To calculate the maximum allowable cable length of high-flex RG-6 cable (1786-RG6F): ([20.29 db - 16 *.32 db] / 13.5 db) * 1000 = 1123 ft (342.3 m) 1786-RG6F cable 1123 ft (342.3 m) 20162-M

6 ControlNet Standard and High-flex Coax Cable EXAMPLE Example 3: Determining the maximum allowable length of standard cable when mixing standard RG-6 and high-flex RG-6F cable in the same system In this example, the segment: has 7 nodes (requires 7 s) requires 656.2 ft (200 m) high-flex 1786-RG6F cable 1. Calculate the amount of standard 1786-RG6 cable that is equivalent to 656.2 ft (200 m) of 1786-RG6F cable by multiplying the ratio between the two attenuations by the length of RG-6F cable. (13.5 db / 5.99 db) * 656.2 ft (200 m)= equivalent length of standard RG-6 Equivalent length of standard 1786-RG6 = 1478.9 ft (450.8 m) 2. Calculate the remaining allowable maximum length of standard 1786-RG6 cable. 3280 ft (1000m) - 1478.9 ft (450.8 m) = 1801.1 ft (549.2 m) 3. Calculate the remaining allowable length on a segment with 7 s. 1801.1 ft - (53.4 ft * [7-2]) = 1534.1 ft (467.6 m) 1786-RG6 cable 1786-RG6F cable 1534.1 ft (467.6 m) 656.2 ft (200 m) 20162-M

ControlNet Standard and High-flex Coax Cable 7 Installing ControlNet Cable Use these components to help you install your ControlNet cable. component: ControlNet Cable System Planning and Installation Manual ControlNet Coax Toolkit publication or catalog number: CNET-IN002 1786-CTK Cable Specifications cable life (1786-RG6F only) operating temperature storage temperature relative humidity 3-in. radius = 1.5M flextures (calculated using a rolling C track test with a 3-in. radius) 0-60 C (32-140 F) -40-85 C (-40-185 F) 5-95% non-condensing

Rockwell Automation Support Rockwell Automation provides technical information on the web to assist you in using our products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com. Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your module up and running: United States 1.440.646.3223 Monday Friday, 8am 5pm EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues. New Product Satisfaction Return Rockwell tests all of our products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned: United States Outside United States Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process. Please contact your local Rockwell Automation representative for return procedure. PN 957859-70 Supersedes Publication 1786-5.9 - September 1997 Copyright 2003 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.