Mini-2Bay RAID Subsystem, (RAID 0,1 selectable) w/ combo 1*USB 2.0 Connector and 1*eSATA (SATAII shielding) Connector User s Manual



Similar documents
How To Play Your Hard Disk Drive On A Mini Hard Disk (Ios) Or Usb (Miii) With A Hard Disk 2 (I2) Or Ios 2 (Mini Usb) With An External Hard Drive (Mini) Or Mini

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Version : 1.0. SR3620-2S-SB2 User Manual. SOHORAID Series

1. User Safety Instructions

ARAID 3500 / S3500 User s Manual

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

ACT-DASR101 Disk Array Series products

3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER

**Please read this manual carefully before you use the product**

xage-902 Series 2008 COMPUTEX Taipei BEST Choice Award Design & Innovation Award istarusa FOR 2.5 / 3.5 SATA HDD DOCKING STATION

USER S MANUAL.

Manual IB-3620 Series

USB to IDE SATA Standalone HDD Hard Drive Duplicator Dock. StarTech ID: UNIDUPDOCK

USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM

Dual/Quad 3.5 SATA to USB 3.0 & esata External Hard Drive RAID/Non-RAID Enclosure w/fan. User s Manual

XL-RAID-SATA Data Backup System. User s Guide

How To Set Up A Hard Drive With A Harddrive With A 2Gb Hard Drive (I386) And 2Gb Drive (Amd64) On A Hardrive (I219) (Iee) (Amd66) (Ai219

To simplify monitoring of drive activity, the enclosure features six front panel LED indicators that provide constant operation and status updates.

Hydra Super-S Combo. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 29, v1.3

USB to IDE SATA Standalone Hard Drive Duplicator Dock StarTech ID: UNIDUPDOCK

2» 10» 18» 26» PD »

USB to IDE SATA Standalone HDD Hard Drive Duplicator Dock. StarTech ID: UNIDUPDOCK

How To Set Up A Hard Disk Drive With A Rkd (Sr5650) And A Hard Drive (Srs5650-Wbs1/Sb2)

XL-RAID-SATA2-USB. User Manual. v.1.2 (January, 2010)

HARDWARE SUBRAID. SUBRAID MAX II STD rebuilds backup system

Mini-EPic System of RAID

is605 Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives FW400 + FW800 + USB2.0 Combo External RAID 0, 1 Subsystem User Manual

Version : 1.1. SR2760-2S-S2 User Manual. SOHORAID Series

Tyan Computer. Transport PX22. Service Engineer s Manual

How To Use A Sata Dsa Hard Disk Storage System

User s Manual. Home CR-H BAY RAID Storage Enclosure

Installation Manual (AZ-SBC98) SATA SUBRAID V3

5-BAY RAID STATION. Manual

Standalone 1:3 SATA 2.5 / 3.5 Hard Drive Duplicator and Eraser w/ Daisy Chaining. StarTech ID: SATDUP13

Taurus - RAID. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. User Manual

ST 2350 RES SATA RAID User Manual

- 1 - Model: (SATA to USB+Hub+1394a) Code Description: S---SATA Harddisk. ES---ESATA Interface. U---USB2.0 Interface. F---IEEE1394 Interface

ATA TO IDE INTERFACE PC CARD DRIVES

CHENBRO. RM Port 6Gb/s Mini-SAS Backplane 80H A0. User s Manual. Sep / 30 / 2010

2 Bay USB 3.0 RAID 3.5in HDD Enclosure

for 3.5 Serial ATA Hard Drive with One-touch Backup G-S350SU

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure for four 3.5-inch Serial ATA Hard Drives. User Manual August 18, v1.0

USB 3.0 Standalone Eraser Dock for 2.5 & 3.5 SATA Drives. StarTech ID: SDOCK1EU3P

FUSION R400 RAID USB 3.0

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

Hydra esata. 4-Bay RAID Storage Enclosure. User Manual January 16, v1.0

Mini-EPICa SATA II-to-SATA II RAID SUBSYSTEM

Dismantling or replacement by the user. Connection to an alternate power source. Malfunction due to natural disasters (fire, flood, tsunami, etc.

BounceBack Server Solution Reference Guide

Dynamode External USB3.0 Dual RAID Encloure. User Manual.

GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4

FANTEC MR-35DU3-6G USER MANUAL

DTX 2100S SCSI RAID-1 Dual HDDs

esata External Storage

Serial ATA to Serial ATA

USB3.0 Docking Station. User Manual (DA-70546)

EC2-2 Port esata Card Quickstart

FANTEC MR-35HDC HARD DISK COPYSTATION

DX513 User s Guide. Syno_UsersGuide_DX513_

easyraid Q12 Hardware User Manual

ToughTech Duo Users Manual

G-SPEED es Mac Installation Guide

2 Bay FireWire 800/400/USB RAID Solution RAID 0, RAID 1, & JBOD. User Manual

How To Use An Esata External Hard Drive Enclosure (I386) With A Usb 2.0 And Usb 2/1.1 Hard Drive (I219) On A 2.5\" Hard Drive On A Mini Hard Drive Or An Ip

G-SPEED es PRO Mac Installation Guide (with G-Tech PCIe RAID controller)

4-Drive-Bay Advanced Gigabit Network RAID Storage System Chassis

2big Quadra ENTERPRISE CLASS. Professional 2-Disk RAID DESIGN BY NEIL POULTON. esata 3Gb/s FireWire 800 & 400 USB 2.0

RTX. RTX 430-3QR User Manual. Quadruple Connectivity RTX430-3QR is compatible with four different interfaces; USB3, USB2, esata, and FireWire 800.

(4-Port esata/usb2.0 to SATA RAID Box)

3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering

PCIe SATA 6G Raid Card

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

StudioRAID mini. Production-Quality Portable RAID USB 3.0, FireWire 800, esata host connectivity

Product Specifications. Dual bay NAS KD20. OMNINAS - Your Personal Cloud. Feature Highlights. Shuttle Order No: NAS-KD20001

SuperWiper Quick Connect (SWP-0001)

PL2775 JBOD / BIG / RAID0 / RAID1 Mode Application

SATA/eSATA II PCI & PCI-E Card & CardBus

VIA / JMicron RAID Installation Guide

MCR1900 Media Converter 19-Slot Chassis

ReadyNAS OS 6 Desktop Storage Systems

VTrak SATA RAID Storage System

4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card

Cisco Small Business NSS2000 Series Network Storage System

=============================== WARNING

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

SPC-530. Rackmount Server PC. User's Manual

Cserver 1180 / Basic Operating Manual

Portable esata USB to SATA Standalone HDD Hard Drive Duplicator Dock. StarTech ID: SATDUPUEGB

SanDisk Solid State Drive

Recovering from a Hard Drive Failure

ACS RAID controller User Manual

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0

The Introduction of ORICO 3549RUS3

DF to-2 SATA II RAID Box

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

G-RAID 2 - Award Winning RAID 0 Storage System

G-RAID 2 - Award Winning RAID 0 Storage System

Transcription:

- 0 - Mini-2Bay RAID Subsystem, (RAID 0,1 selectable) w/ combo 1*USB 2.0 Connector and 1*eSATA (SATAII shielding) Connector User s Manual

- 1-1. Product Overview Features: * Aluminum housing, anodized surface, benefits for cooling and durability * Small, compact, and light weight * Backplane design for two removable SATA drive trays * Built-in thermo speed control fan for self-contained ventilation * Individual key lock of each HDD tray for physical security * LED indicators on each HDD tray, support HDD activity, HDD fail, RAID Level, FAN/TEMP (environmental monitoring) * Built-in microprocessor for hardware RAID 0, 1 (selectable) * Built-in buzzer alarm * Support RAID 1 mode capability of Hot-Swap, AUTO rebuilding Descriptions: External Dual 3.5 HDD Enclosure support Hardware RAID, Host Interface support USB 2.0 and Serial ATA. Specifications: Host Interface HDD Interface Data Transfer Rate RAID Level USB2.0 and SATAII SATA I, II USB 2.0 480Mbps ( 60MB/sec ) SATA 1.5/3.0 Gbps Hardware RAID 0, 1 (selectable) Hot-Swap Both on Host and Device (RAID 1 only ) 1. LED for RAID RAID 0-->orange RAID 1-->green LED Display 2.LED for FAN/TEMP detect Normal-->green Fan failure-->red Over temperature-->orange 3.LED for each HDD Access-->blue Fail-->red Rebuilding-->pink/blue flashing

- 2 - Alarm Buzzer beeping when any event occur Temperature too high (over 50 C), Fan fail and HDD Fail Thermo Detect.- threshold temperature is 50 Environment Management Power Supply Cooling O.S. support Dimension Material Fan Detect Fan speed too low or fan stop Fan speed control according to detected temperature HDD status detect External Power Adapter (AC input:100-240v~1.0a 50-60Hz / DC output:+5v/2a,+12v/2a) 4.0 x 4.0 x 1.0 mm cooling Fan with FAN speed control (If temperature goes up, fan will turn faster for better self-ventilation.) OS independent Enclosure only: (L):23.5cm (W):6.5cm (H):12cm Including Stand: (L):26.9cm (W):8.7cm (H):14.1cm Plastic and Aluminum alloy Package Content: - Enclosure x 1 - Stand x 1 - HDD Tray x 2 - USB2.0 Cable x 1 - SATAII Shielding x Cable x 1 - Power Adapter w/ Power Cord x 1 - Hard Disk Drive mounting screw x 8 - Key for HDD tray x 2

- 3-2. Quick Installation Guide a. Connect USB cable from host to USB port; or, connect SATA cable from host to esata port. b. Connect power cord from power adapter to DC power receptacle. c. Select RAID level, RAID 0(striping) or RAID1(mirroring). d. Turn on power switch, then you can start playing this unit. RS-232 Port RAID Switch USB Port Power Switch esata Port DC Power Receptacle

- 4-3. RAID Level Re-configuration For re-configuring the RAID microprocessor, please 1. Change RAID level 2. Turn off power 3. Turn on power CAUTION: After changing the RAID level, HDDs will be reconfigured on restarting the device. 4. AUTO-Rebuilding / Hard-Copy RAID 1 support only Auto rebuilding can be applied for data security, which ensures the data recover with AUTO rebuilding function, Hot-Copy features HDD duplicating with or without host connection. For hot-swapping, 1. Remove one HDD from any of equipped subsystem without shutting down the Operating System. 2. Keep accessing with the HDD left, you d hear the buzzer beeping due to the missing HDD. 3. Re-plug the removed HDD, then buzzer will stop beeping and you ll see the LED for HDD flashing while AUTO rebuilding. For duplicating data to another disk, 1. Ensure the subsystem is under RAID 1 mode. 2. Ensure which HDD contains complete data and plug the HDD into any bay of it first, before or after powering on. 3. Ensure the firstly installed HDD has been recognized by subsystem the firstly installed HDD will be regarded as SOURCE. Meanwhile, you d hear the buzzer beeping due to the missing HDD. 4. Plug another HDD into another drive bay - the newly installed HDD will be regarded as DESTINATION Then buzzer will stop beeping and you ll see the LED for HDD flashing while data duplicating.

- 5-5. Frequently Asked Questions Q: Why RAID 0 works well, but RAID 1 seems not work? A: Please reconfigure the RAID chip just refer to RAID Level Reconfiguration. Q: Why RAID 1 works well, but RAID 0 seems not work? A: Please reconfigure the RAID chip just refer to RAID Level Reconfiguration. Q: Why does the Buzzer keep beeping? A: Please refer to LED Display of Product Overview to check: 1) if the fan/tempt error, the environment might be too hot, or you ve run the subsystem too long. please try to make your environment cooler or let your subsystem take a short rest higher rpm (i.e. Western Digital Raptor 10K rpm) or various brand HDDs may create more heat inside enclosure according to our internal test, Seagate HDDs are less hot 2) if HDD fail, under RAID 1 mode you may just swap one HDD, please plug another HDD ASAP Caution: only RAID1 mode can support hotswap, the subsystem will start AUTO rebuilding after re-plugging the removed HDD Or, one HDD may fail, please replace your HDD Caution: only RAID1 mode can support hotswap, the subsystem will start AUTO rebuilding after re-placing HDD 3) if HDD fail, under RAID 0 mode you may just swap one HDD, or one HDD may fail, unfortunately, we have to inform you the RAID volume just crashed, just kiss your data goodbye. Caution: RAID0 mode can t support hotswap, HDD fail or swap the HDD may cause data destroyed Q: If powering off during AUTO rebuilding will it start from beginning or continue from the last track? A: Continue from the last track.