Loop Start or Ground Start?



Similar documents
The Evolution of Requirements for Supervising Station Alarm Systems

UL s Perspective on IP Signaling Larry Shudak Principal Engineer Signaling and Security Control Equipment Underwriters Laboratories Inc.

Alarm Systems Using Wireless or Other Transmission Technology as a Single Path of Communication. Purpose. References. Description of Code Reference

Phone Company or Phony Company? Part 2 by Dean K. Wilson, P.E.

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM RECORD OF COMPLETION

Module 4, Lesson 12 Fire Alarm Systems

Fire Prevention Coffee Break Training. November 2015

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS

How Call Forwarding Works

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

SECTION 6 SUPPLEMENTAL SERVICES

Lumos Networks of West Virginia Inc. d/b/a Lumos Networks Telephone - PA PUC Tariff No. 1 Section 2 Original Page No. 1

White Paper. Why Cellular as a Single Transmission Path meets the Requirements of NFPA 72. The Gradual Demise of POTS

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

Overview of the Telecommunications Network

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

ANALOG TELEPHONE SET USER GUIDE

Telephony Features and Instructions

How To Understand The Concept Of Circuit Switching

Traditional Telephony

Fire Alarm System Monitoring - CAN/ULC-S561-03

Three Network Technologies

NAPCS Product List for NAICS 517: Telecom Products

SOLUTION BRIEF. Motorola FSA4000. How to Achieve Near 100% Fire Station Alerting Reliability

An ADTRAN White Paper. Integrating LAN Fax Servers over T1 and PRI Services

Supplement No Telephone PA P.U.C. - No. 5

EC500 User Guide. Michigan State University Avaya Campus PBX

Reject calls from callers who block their Caller ID information so their calls don't even ring on your line.

Station-User Guide For Meridian Multi-Line Telephones

Glossary of Telco Terms

APPENDIX A GENERAL DEFINITIONS & SERVICE FUNCTIONS

VALLEY TELEPHONE COOPERATIVE, INC. SECTION 17 MEMBER SERVICES TARIFF DIGITAL CENTREX SERVICE. Table of Contents

Trunk Signaling. Figure 1 Subscriber Loop Signaling and Trunk Signaling

RESIDENTIAL PHONE FEATURES

Internet Telephony Terminology

Monthly Charge For each 1/4 mile or fraction thereof:... $1.00

CAN/ULC-S Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

._-_. Appendix 1 Page 22. CFDA To DID Intraswitch (8022)

Title: Telecommunications Internetworking Author: P.J. Louis Publisher: McGraw-Hill ISBN:

Supplement No Telephone Pa. P.U.C. No. 5 Palmerton Telephone Section 4 Company Sixth Revised Sheet 1 Canceling Fifth Revised Sheet 1

PART 7 - Central Office Optional Features 1st Revised Sheet 1 SECTION 3 - Complementary Network Services (CNS)

Wireless Mesh Networks and Applications in the Alarm Industry. A Technology Overview. Presented by

Section 314: TELECOMMUNICATION AND RELATED SERVICES SOURCING RULE A. Except for the defined telecommunication services in subsection (C), the sale of

Technical Note. TN: Technical note for phone access of HMS system. Rev. a

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

To activate Anonymous Call Rejection: 1. Lift the receiver and listen for dial tone. 2. Dial * Listen for confirmation tone, hang up.

This service allows you to talk to the 3rd party before transferring the original called party to them. To use Attended Call transfer:

RIT Extension to Cellular User Guide

Illinois Department of Revenue Regulations. Title 86 Part 100 Section Sales Factor for Telecommunications Services TITLE 86: REVENUE

Before the FEDERAL COMMUNICATIONS COMMISSION Washington, DC 20554

Line Rental (WLR) A to Z Glossary

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

SECTION 5 NETWORK SERVICES

CALLING FEATURE USER GUIDE

Telephony Fundamentals

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

Alti-Mobile Extensions

Voice and Delivery Data Networks

Configuring the 930A for Common PBX Metallic Signaling Interfaces

INSPECTION AND TESTING FORM

Chapter 4. Regulation of Alarm Systems

Telecommunications systems (Part 1)

Definitions. "All Ireland Landline Numbers" means fixed telephone exchange line numbers in the State (including Northern Ireland).

NORTH STATE TELEPHONE Section 13 COMPANY Original Sheet 1 High Point, North Carolina Effective: December 31, 2008 GENERAL EXCHANGE PRICE LIST

Analog User Guide HUMBOLDT STATE UNIVERSITY. Telecommunications & Network Services

Vanguard Managed Solutions. Understanding Voice Technology - Vanguard Technical Reference

Calling Feature Instructions Digital Phone By Telephone

Course 1. General view on the fixed telephone network. Digital networks. General aspects. Definitions.

Agenda. Agenda (continued) Fundamentals of Fire Alarm Systems

Digital Phone Features Guide

Configuring the ADTRAN ATLAS for a Rabbit-Hole Application

ACCESS CHARGE A fee charged subscribers or other telephone companies by a local exchange carrier for the use of its local exchange networks.

With 360 Cloud VoIP, your company will benefit from more advanced features:

Chapter 67 ALARM SYSTEMS

Definitions for KRS , , , and As used in KRS , , , and : (1) "Ancillary services"

Recommendation T/SF 42 (Odense 1986) SERVICES AND FACILITIES ASPECTS OF 2ND GENERATION CORDLESS TELEPHONES

Advanced Calling Features Guide

YOUR HOME PHONE. Horry Telephone Cooperative, Inc.

COCHRANE TELECOM SERICES CRTC TELEPHONE SYSTEM PAGE 1 REVISION 8 GENERAL TARIFF SECTION 210 CENTREX SERVICE 1. GENERAL

SECTION DETECTION AND ALARM

PATTON TECH NOTES What are FXS and FXO?

AT&T Price List. Voice Communications Network Services Contract Contract Number 85016

TalkBroadband TM Quick Feature Guide

Customer Interface Publication: KCH CIP002. Public Switched Telephone Network (PSTN)

Network Neutrality Statement

Transcription:

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 1 Loop Start or Ground Start? by Dean K. Wilson, P.E. Question: The new telephone system installed in our office building has telephone voice mail. To signal a user that he or she has a message waiting in his or her telephone voice mail box, the system produces an interrupted dial tone. We plan to install a new fire alarm system throughout the building. We also plan to connect this new system to a remote supervising station using a Digital Alarm Communicator System. If we connect a Digital Alarm Communicator Transmitter to one of these lines, how will the DACT be able to recognize dial tone when telephone voice mail causes an interrupted dial tone? Answer: The telephone system you describe appears to be one of the modern, digital private branch exchange (PBX) systems, manufactured by such highly-respected telecommunications companies as Northern Telecom or Lucent Technologies. This system consists of a digital private branch exchange electronic telecommunications switch located in one of the equipment rooms in your building. The telephone lines that serve all the telephones throughout your building terminate in that equipment room. The PBX switch controls those lines and provides the many features associated with your state-of-the-art telephone system. In addition to the large number of internal telephone lines running throughout your building, the telephone company utility that provides service to your building has connected a certain number

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 2 of incoming telephone trunk lines. These circuits extend to your building from the nearest telephone company wire center. The telephone company utility has also connected a certain number of outgoing telephone trunk lines. These circuits also extend to your building from the nearest telephone company wire center. When someone dials your telephone number, a main telecommunications switch in a telephone company wire center directs the call to the PBX switch in your building. The PBX switch, in turn, directs the call to your telephone extension. If you do not answer within a designated number of rings, or if another call already has you on the line, the PBX switch will transfer the new caller to your telephone voice mail. When the caller leaves you a message, the PBX switch creates the interrupted dial tone to let you know a message waits in your telephone voice mailbox. NFPA 72-1996, National Fire Alarm Code, does not permit Digital Alarm Communicator Transmitters or Digital Alarm Communicator Receivers to connect to the type of telephone trunk lines that providing incoming and outgoing telephone service to your building. Subsection 4-5.3.2.1.1 requires: 4-5.3.2.1.1 A DACT shall be connected to the public switched telephone network upstream of any private telephone system at the protected premises. In addition, the connections to the public switched telephone network shall be under the control of the subscriber for whom service is being provided by the supervising station fire alarm system, and special attention shall be required to ensure that this connection is made only to a loop start telephone circuit and not to a ground start telephone circuit. Notice that this subsection requires that the fire alarm system installer must connect the DACT directly to the public switched telephone network, and particularly to a loop start

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 3 telephone line. This requirement prohibits the connection to a line downstream PBX because such a line does not serve as a direct path to the public switched telephone network. Further, quite typically the incoming and outgoing trunk lines that serve the PBX are ground start lines. A loop start telephone line has voltage present on the line at all times (nominally 48 VDC). The telephone company calls this voltage central office battery. By monitoring the presence of this voltage, the DACT complies with the requirement of subsection 4-5.3.2.1.6.2(a). In effect, the DACT monitors the integrity of each of its telephone line connections between the protected premises and the first telephone company wire center. When a caller lifts a telephone handset to make a call, the change in loop resistance signals the telephone company wire center to supply dial tone. A ground start telephone line does not have voltage present on the line at all times. Thus, the DACT cannot monitor the integrity of such a ground start line. In actual practice, when a caller uses the PBX to dial an outside telephone call, the PBX switch signals the telephone company wire center to supply dial tone by momentarily grounding one side of the telephone circuit. This action gives the type of line the name ground start. Today, system designers do not have to limit designs only to systems that use telephone lines. Modern technology presents a variety of options for transmission of signals from a Digital Alarm Communicator Transmitter. The National Fire Alarm Code includes these technologies: 4-5.3.2.1.6.1 A DACT shall employ one of the following combinations of transmission channels: (a) Two telephone lines (numbers); (b) One telephone line (number) and one cellular telephone connection; (c) One telephone line (number) and a one-way radio system;

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 4 (d) One telephone line (number) equipped with a derived local channel; (e) One telephone line (number) and a one-way private radio alarm system; (f) One telephone line (number) and a private microwave radio system; (g) One telephone line (number) and a two-way RF multiplex system. 4-5.3.2.1.6.2 The following requirements shall apply to all combinations in 4-5.3.2.1.6.1: (a) Both channels shall be supervised in a manner appropriate for the means of transmission employed. (b) Both channels shall be tested at intervals not exceeding 24 hours. Exception No. 1: For public cellular telephone service, a verification (test) signal shall be transmitted at least monthly. Exception No. 2: Where two telephone lines (numbers) are used, it shall be permitted, until June 1, 1998, to test the primary telephone line (number) at 24-hour intervals without testing the secondary line (number). After June 1, 1998, where two telephone lines (numbers) are used, it shall be permitted to test each telephone line (number) at alternating 24-hour intervals. (c) The failure of either channel shall send a trouble signal on the other channel within 4 minutes. (d) When one transmission channel has failed, all status change signals shall be sent over the other channel. Exception: Where used in combination with a DACT, a derived local channel shall not be required to send status change signals other than those indicating that adverse conditions exist on the telephone line (number). (e) The primary channel shall be capable of delivering an indication to the DACT that the message has been received by the supervising station. (f) The first attempt to send a status change signal shall utilize the primary channel. Exception: Where the primary channel is known to have failed. (g) Simultaneous transmission over both channels shall be permitted. (h) Failure of telephone lines (numbers) or cellular service shall be annunciated locally. These varied technologies open opportunities to apply clever and creative solutions in solving specific fire protection problems at various facilities. With this increase in the tools

Fire Alarm Notebook by Dean K. Wilson. P.E. Page 5 available to the designer of fire alarm systems, the designer and the installer must make certain they carefully observe the subtleties of the requirements contained in these subsections of the National Fire Alarm Code. If they fail to do this, problems with the transmission technologies could render a Digital Alarm Communicator System inoperable. Such a failure might not signal its out of service condition to the remote supervising station. Even worse, fire alarm signals might not reach the remote supervising station. Without a properly communicated signal, the operators at the remote supervising station would not know to dispatch the emergency responders. Once again, the requirements of NFPA 72, 1996, National Fire Alarm Code, serve as a benchmark of quality. By comparing the performance of a proposed fire alarm system to the requirements of the Code, designers and installers can make certain the system will function as the building owner or occupant intends. This will allow the fire alarm system to provide genuine protection, and not simply give a false sense of security. IMSA member Dean K. Wilson, a licensed professional fire protection engineer with an office in Windsor, CT, serves as a Senior Engineer with the fire protection engineering consulting firm, Hughes Associates, Inc. (www.haifire.com). The opinions expressed in this article are strictly his own. You can reach him by phone at (860) 687-1009; by FAX at (860) 687-1308; or by e-mail at dwilson@haifire.com.