FDA Guidelines for Magnetic Resonance Equipment Safety



Similar documents
Basic Principles of Magnetic Resonance

MRI SAFETY JEOPARDY (Technologist Edition) Questions

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

Human Exposure Limits

REVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual

Electromagnetic Field Safety

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Physics of MRI Safety

Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use

RICHARD T ELL ASSOCIATES,INC.

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager

A Primer on Medical Device Interactions with Magnetic Resonance Imaging Systems

ELECTRICITE ET MAGNETISME.

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

ELECTRON SPIN RESONANCE Last Revised: July 2007

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Magnetic Resonance Imaging

Current Probes. User Manual

Current and Temperature Ratings

MRI SAFETY JEOPARDY (NON Technologist Edition) Questions

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

X-ray Imaging Systems

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

Prepublication Requirements

Problem 1 (25 points)

Lecture 14. Introduction to the Sun

Magnetic Resonance Imaging Environment Safety in Ontario

Subject: Magnetic Resonance Imaging (MRI) Information on Sorin Group Heart Valve Prostheses and Annuloplasty Devices

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Physical Quantities, Symbols and Units

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Pulsed Power Engineering Diagnostics

Numerical Modelling of E-M Occupational Exposures associated with MRI

Advanced Measurements of Microwave Oven Leakage

Selected Radio Frequency Exposure Limits

Non-Ionizing Electromagnetic Radiation

Theory of Heating by Induction

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D Kamp-Lintfort

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

LONI De-Identification Policy

UC Davis Imaging Research Center. MRI Online Safety

Effect of Metallic Materials on SAR

BS D American Board of Magnetic Resonance Safety MRMD,MRSO, MRSE Examination Content Syllabus Version 1.5 Friday, February 06, 2015

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Forms of Energy. Freshman Seminar

Magnetic Resonance Imaging

Human exposure to RF

Breast MRI Quality Control

Series 6000 Torque measured metal bellow coupling

ETSI TR V1.1.1 ( )

MRI Department Goals. Effective Ways to Improve Patient Cooperation and Safety in MRI Exam. Lecture Topics

Magnetic susceptibility. Basic principles and features on the PPMS.

Temperature Rise Measurements

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

GUIDE TO SETTING UP AN MRI RESEARCH PROJECT

Wireless Broadband: Health & Safety Information

GE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R

SITE IMAGING MANUAL ACRIN 6698

Pulsed Fourier Transform NMR The rotating frame of reference. The NMR Experiment. The Rotating Frame of Reference.

DEGREE: Bachelor's Degree in Industrial Electronics and Automation COURSE: 1º TERM: 2º WEEKLY PLANNING

510(k) Summary. This summary of 510(k) safety and effectiveness is being submitted in accordance with the requirements of 21 CFR 807.

Application Information

Invited. Pre-MRI Procedure Screening: Recommendations and Safety Considerations for Biomedical Implants and Devices

Chapter 22: Electric motors and electromagnetic induction

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

Environment-Laboratory Ambient Conditions

Fundamentals of Power

ACR WHITE PAPER ON MAGNETIC RESONANCE (MR) SAFETY Combined Papers of 2002 and 2004

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

MRI Physics for Radiologists

Environmental Health and Safety

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC

PHY114 S11 Term Exam 3

Conductive and Radiative Heat Transfer in Insulators

5. Measurement of a magnetic field

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Faraday s Law of Induction

Logging of RF Power Measurements

RADIOFREQUENCY RADIATION, (RFR): (RFR Information - Technology Newsletter, Full Version)

5SDD 92Z0401. Housingless Welding Diode. I FAVm = A I FSM = A V TO = V Applications r T = m. Types.

Magnetism Basics. Magnetic Domains: atomic regions of aligned magnetic poles Random Alignment Ferromagnetic Alignment. Net Effect = Zero!

DIRECT CURRENT GENERATORS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Application Notes. Magnetics. Determining L min for Buck/Boost Converters

Series 7500 Torque Sensor

Medical Imaging. MRI Instrumentation, Data Acquisition, Image Reconstruction. Assistant Professor Department of Radiology, NYU School of Medicine

ACL 395 Resistivity Meter

Vibration Isolation in Data Centers

Millennium Product Inc. Model: Cell Shield / Zorb

Effects of Cell Phone Radiation on the Head. BEE 4530 Computer-Aided Engineering: Applications to Biomedical Processes

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

University of Minnesota Center for Magnetic Resonance Research Standard Operating Procedure Human System Magnet Operator Training

Transcription:

FDA Guidelines for Magnetic Resonance Equipment Safety Loren A. Zaremba, Ph.D. Center for Devices and Radiological Health Food and Drug Administration Outline I. Introduction II. Static Magnetic Field III. Radio Frequency (RF) Magnetic Field IV. Gradient Magnetic Fields V. Implanted Medical Devices I. Introduction 1. Magnetic fields in MRI 2. Safety concerns 3. Safety organizations 4. Safety standards 5. IEC/FDA operating modes for MRI diagnostic equipment Magnetic Fields in MRI Main static field aligns spins Radio frequency field (fm band) flips spins) Gradient field used for spatial encoding the image

Safety Concerns in MRI Force and torque on magnetic materials cause static magnetic field Heating cause RF magnetic field used to flip spins Nerve stimulation cause gradient magnetic fields used for spatial encoding Implanted medical devices - all of the above MRI Safety Organizations International Electrotechnical Commission (IEC) Food and Drug Administration (FDA) National Electrical Equipment Manufacturer s Association (NEMA) American Society for Testing and Materials (ASTM) American College of Radiology (ACR) MRI Safety Standards IEC 60601-2-33 Requirements for the Safety of MR Equipment for Medical Diagnosis FDA Guidelines for Premarket Notifications for MR Diagnostic Devices NEMA MS 1 through 9 Safety and Performance Standards ASTM Test Methods for MR Safety of Implanted Medical Devices ACR Site Safety Guidelines IEC/FDA Operating Modes for MRI Diagnostic Equipment Normal Mode Will not cause stress suitable for all patients First Level Controlled Mode may cause stress requires medical supervision and positive action by operator to enter Second Level Controlled Mode II. Static Magnetic Field 1. Magnetic force and torque on objects 2. Force vs. distance from magnet 3. Comparison of force on object in 1.5T and 3.0T scanners 4. IEC/FDA requirements for static magnetic fields 5. Status of high field MRI safety studies Force on Magnetic Dipole in Increasing Magnetic Field Field lines, B, compress at magnet opening Produce inward radial components, Br, of field Resultant attractive force into magnet

Torque on Magnetic Dipole in Magnetic Field Magnetized material acts like dipoles Magnetic field produces torque to align dipole with field No net force in uniform field Basic Force and Torque Relations T = mxb F = grad(m*b) Force on paramagnetic or unsaturated ferromagnetic object is maximum where product of B and grad B is maximum Force on saturated ferromagnetic object is maximum where grad B is maximum Force vs. Distance from Magnet Entrance Increases very rapidly as approach magnet Increases approximately as square of field strength Depends on type of magnet (open, self-shielded, etc.) Comparison of 1.5T and 3.0T Scanners Force on paramagnetic material (e.g. stainless scalpel) is 5 times greater on the 3T system Force on ferromagnetic object (e.g. steel wrench) is 2.5 times greater on 3T system IEC/FDA Requirements for Static Magnetic Fields Field maps must be supplied by manufacturer Regions over 5 gauss controlled access Normal mode (suitable for all patients) up to 2T First level controlled mode (medical supervision) up to 4T IEC over 4T requires IRB approval FDA over 4T requires investigational device exemption (IDE)

Status of High Field MRI Safety Studies Systems up to 8T in operation on human subjects Subjects monitored for ECG, heart rate, respiration, etc. Cognitive studies have been done on a limited number of subjects Safety studies indicate no serious adverse effects Only effects seen so far are temporary and not serious (vertigo, nausea, metallic taste, etc.) III. Radiofrequency (RF) Magnetic Field 1. RF heating in MRI theory 2. RF heating in clinical MRI 3. How a scanner estimates SAR 4. IEC/FDA limits for whole body and localized heating 5. Measuring SAR pulse energy and calorimetric methods RF Heating in MRI Theory Heating is inductive (Faraday Law) Power increases approximately as square of frequency and radius Power increases approximately as square of field strength and patient size Most heat is deposited on perimeter of body where it can be more easily dissipated Regions with high resistance can cause focal heating

RF Heating in Clinical MRI Concerns are core (whole body) and localized heating Not practical to routinely measure temperature of patients Use Specific Absorption Rate (SAR) to estimate temperature increase SAR = absorbed power/mass (e.g watts/kg) SAR of 1 W/kg would increase temperature of an insulated slab about 1 degree C/hour How a Scanner Estimates SAR Scanner runs a calibration routine Determines energy needed to get a 90 and 180 degree flip Adds up energy of all RF pulses in a sequence and divides by pulse repetition time (TR) to get power Divides by patient weight to get whole body SAR Peak local SAR is usually estimated as 2.5 times higher on most scanners IEC/FDA Limits for Whole Body Heating Normal mode limit (suitable for all patients) 0.5 degrees C or 2 W/kg First level controlled mode (medical supervision) 1.0 degrees C or 4 W/kg Second level controlled mode greater than 1 degree C or 4 W/kg (requires IRB approval) IEC/FDA Limits for Localized Heating Head normal mode limit 38 degrees C or 3.2 W/kg averaged over head mass Torso normal mode limit 39 degrees C or 10 W/kg over any 10 grams Extremities normal mode limit 40 degrees C or 10 W/kg over any 10 grams No first level for head, torso or extremities Methods for Measuring SAR Developed by National Electrical Manufacturers Association (NEMA) NEMA Standard MS-8 Characterization of SAR for MRI Systems Two basic methods pulse-energy method and calorimetric method Used by manufacturers to calculate SAR for their scanners Pulse-Energy Method for Measuring Whole Body SAR Equipment Directional coupler to measure forward and reflected power Oscilloscope to measure peak-to-peak voltages Non-loading phantom to measure coil losses Loading phantom to measure sample losses

Calorimetric Method for Measuring Whole Body SAR Use insulated loading phantom Measure temperature increase Calculate absorbed energy and SAR IV. Gradient Magnetic Fields 1. Gradient coils and current waveforms 2. Effects on patient (nerve stimulation) 3. Relationship between pulse duration and stimulation threshold 4. IEC/FDA limits MRI Gradient Coils and Current Waveforms Apply linear magnetic fields for spatial encoding Trapezoidal pulses pulse train for echo planar imaging Hyperbolic Relationship Between Pulse Length and Stimulation Threshold db/dt = b(1+c/d) b = rheobase c = chronaxie c = 3 msec for cardiac muscle c = 0.38 msec for nerves d = duration of stimulus Nerve stimulation begins as barely noticeable, but can be uncomfortable or painful Large variations in patient response to stimulation

New IEC/FDA Limits for Gradients Old limit was db/dt = 20 T/sec for normal mode Now three ways to satisfy requirements Direct determination (volunteer studies) Default db/dt limits for whole body gradients Default E field limits for all types of gradients Direct Determination of Gradient Limits Applies to whole body and special purpose gradients Observe stimulation threshold in at least 11 volunteers Check different pulse durations and axes Normal mode limit at 80% of observed mean threshold First level limit at 100% of observed threshold Default Limits for Whole Body Gradients in Terms of db/dt Normal mode db/dt = 0.8rb(1+0.36/tau) First level db/dt = 1.0rb(1+0.36/tau) Rb = rheobase = 20 T/sec Tau = stimulus duration (msec) Default Electric Field Limits for All Gradients Normal mode E = 0.8rb(1+0.36/tau) First level E = 1.0rb(1+0.36/tau) Rb = rheobase = 2.2 volts/m Tau = stimulus duration (msec) New IEC Limits for Combined Gradient Output Weighted quadratic addition rule or validated alternative Default or directly determined weight factors for the different gradient directions In 1995 standard db/dt was measured with all gradients pulsing simultaneously (more conservative) V. Implanted Medical Devices 1. Safety concerns 2. Theory 3. ASTM measurement methods 4. Example RF heating of neurostimulator

Safety Concerns for Implanted Medical Devices Force and torque on magnetic materials RF heating Induced voltages/currents on implant altered operation ASTM Force Measurement Method Suspend implant from string Position so that implant is at position of maximum attractive force Measure string angle At 45 degrees attractive force = gravity ASTM Torque Measurement Method Implant placed on holder suspended by calibrated torsional spring Apparatus placed at magnet center Torque determined from deflection angle RF Heating of Implant Theory Eddy currents are induced in human body by RF magnetic field A conductor, such as a wire, concentrates these currents and may produce intense localized heating at the tip of the wire

ASTM Implant Heating Measurement Method Phantom Phantom material should simulate human electrical and thermal properties Use saline solution to simulate conductivity Use gelling agent to prevent convective heat transfer ASTM Implant Heating Measurement Method Procedure Place implant in phantom to simulate actual position in human body Place fiber optic probes in reference position and positions where heating is expected to be the greatest Apply at least 1 W/kg Measure temperature rise over at least 15 minutes Should be less than 3 degrees C Example RF Heating of Neurostimulator