Temperature Rise Measurements

Size: px
Start display at page:

Download "Temperature Rise Measurements"

Transcription

1 Chapter 22 Temperature Rise Measurements 22.1 Background The SAR in tissue simulating liquid can be assessed by means of temperature rise or by measurements of induced electric field. SAR = c T dt (22.1) t=0 SAR = σ E 2 ρ (22.2) For SAR evaluation of low-power wireless devices, the required dynamic range of an E-field probe should range from 2.5 V/m to 400 V/m, which corresponds to a range in temperature rise from 3 µk/s to 40 mk/s. This requirement limits the usage of temperature probes for compliance testings of wireless devices. Besides the low sensitivity, temperature measurements have disadvantage of being extremely time consuming and tedious. However, temperature rise measurements are still widely used in bioelectromagnetic research because the sufficient spatial resolution ( < 1 mm 2 ) can be developed without any difficulties, as well as, for transfer probe calibrations. In this Chapter, basic guidelines for conducting SAR assessments using temperature-rise method are described Temperature Probe Design and Characterization Temperature probe is based on the NTC sensor. The probe tip and body are made of PEEK material with Silicon seals. The probe can be used in water, sugar-water solutions, nutrient solutions and glycol solutions. Maximum storage and usage temperature is from -20 C to 80 (Note: The DAE unit will produce a AD overflow at temperature below zero.) WARNING: The probe tip is very fragile so that the probe has to be handled with utmost care. Do not flex or bend the flexible sensor tip. Always leave the protection cover on the probe, except when making measurements. 22-1

2 The protective cover can be used as a position reference for accurate probe positioning, e.g., in a robot positioning system. The following protocol explains the usage and the role of the protective cover: 1. Make sure that the cover is correctly mounted. 2. Move to the surface with the cover in place. 3. Store the actual position. 4. Move the probe backwards and remove the cover. 5. Go back to the stored position. 6. Move the probe 10.0 mm forward. The probe tip is now just touching the surface. The active element is mm from the surface (for the exact distance see Mechanical page of the probe specifications). IMPORTANT: Always clean the probe with warm water after use in liquid. When the probe has been used in sugar solutions, remove the cover and clean it separately. The cover might become stuck if the sugar crystallizes in its thread DASY Software Settings In the General page the information on the probe type and serial number is stored. For temperature probes Surface Detection is disabled for both detection principles. Schmid & Partner Engineering AG, DASY5 Manual, January

3 Mechanical properties page In the Mechanical page the information on the probe dimensions is stored (probe protective cover is not included!). These are then used in the software to establish the transformation from the robot s tool flange to the probe tip and to align the probe in the light beam unit. These dimensions are specified by Manufacturer and can not be modified by the user. Schmid & Partner Engineering AG, DASY5 Manual, January

4 Sensitivity page The sensitivity factors (a, b, c and d) correspond to the data on the probe calibration sheet and cannot be modified in User or Administrator mode. The Temperature Range indicated the validity of the calibration parameters. The data acquisition electronics read the voltages over the NTC (Uy) and the shunt resistances (Ux, Uz). The temperature is evaluated as follows: ( ) x + d T [ C] = a log + c with x = 2 U y (22.3) 1 b x U x + U z a, b, c, d = DASY software parameters. Note: As with all other SPEAG probes, the probe parameters and specifications depend on the data acquisition (DAE) circuitry Applications The SAR in lossy media can be assessed by measuring the local temperature rise in the media during exposure: SAR[W/kg] c T t with c = heat capacity of the media in J/(kg K) (22.4) Make sure that the media is in thermal equilibrium before exposure, e.g., that there is no temperature gradient before exposure. The media should have ambient temperature. Otherwise convection processes might invalidate the measurement Expose only during the measurement periods. Keep the exposure time and temperature rise as small as possible in order to prevent errors due to heat equalizing processes during measurement periods. Schmid & Partner Engineering AG, DASY5 Manual, January

5 After each exposure restore the media to thermal equilibrium (e.g., through stirring, etc.). Check the results for disturbing heat equalizing processes by repeating the measurements with different power levels and/or different exposure times. Convection processes have a non-linear behavior. Note: The optimal exposure time depends on the viscosity of the media. For water-salt solutions or dibutylglycol-solutions the measurement time should not exceed 5 seconds. For water-sugar solutions the measurement time can be up to 20 seconds. In jelly-like media even higher exposure times are possible. The figure above shows a typical temperature-rise curve. The overall measurement time has been set to 30 s, whereby the RF exposure was turned ON in the 5th second and OFF in the 22nd second (non-linearities in the curve during ON and OFF of the RF power are clearly visible). For the post-measurement evaluation two intervals needs to be defined: time interval for the evaluation of temperature rise (Exposure ON rate) and the initial temperature gradient interval before exposure (Exposure OFF rate). The final result, Net rate is the difference between the two intervals. Note: It is important to verify that the temperature is constant before exposure for thermal equilibrium. The temperature rise during exposure should be a straight line. Any deviation is due to non-liner heat equalizing processes and may lead to the wrong measurement results. Schmid & Partner Engineering AG, DASY5 Manual, January

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI 358858043716587. Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH 92100 FRANCE

SAMSUNG GT-S5369 (mobile phone) Serial number: IMEI 358858043716587. Mr. Antoine SAMAKH and Mr. Mathieu SAMAKH 92100 FRANCE R052-DAS-12-104374-7/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-7/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

Thermal Flow Sensors. Anemometers. Calorimeters. Ensemble of both

Thermal Flow Sensors. Anemometers. Calorimeters. Ensemble of both Thermal Flow Sensors Anemometers Calorimeters Ensemble of both IST Presentation V4-2005 www.ist-ag.com 1 Constant Temperature Anemometer At the heart of a thermal anemometer are two sensors: an air velocity

More information

SAR Comparison Report

SAR Comparison Report Page: 1 of 12 SAR Comparison Report Reference Number: 3103519 Report Number: 3103519EMC01 Revision Level: 0 Client: Lifewave Equipment Under Test: Model Name: Matrix 2 Test Protocol: SAR Comparison Report

More information

EMR-300 Broadband RF Survey Meter

EMR-300 Broadband RF Survey Meter Electric d Magnetic Field Measurement EMR-300 Broadbd RF Survey Meter Available with Isotropic Probes to cover 3 khz to 60 GHz Easy-to-Use Design Lightweight d Rugged Cost Effective Fully Automatic Zeroing

More information

SAR TEST REPORT. According to the standard: EN 62209-1: 2006

SAR TEST REPORT. According to the standard: EN 62209-1: 2006 R052-DAS-12-104374-2/A Ed. 1 This report cancels and replaces the test report R052-DAS-12-104374-2/A Ed. 0 SAR TEST REPORT According to the standard: EN 62209-1: 2006 Equipment under test: Antenna patch

More information

Basic RTD Measurements. Basics of Resistance Temperature Detectors

Basic RTD Measurements. Basics of Resistance Temperature Detectors Basic RTD Measurements Basics of Resistance Temperature Detectors Platinum RTD resistances range from about 10 O for a birdcage configuration to 10k O for a film type, but the most common is 100 O at 0

More information

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort

September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort TTI-P-G 158 Report Dosimetric Assessment of the Mobile Ericsson T18z with an without the PAM System Technologies devices According to the American FCC Requirements September 26, 2000 IMST GmbH Carl-Friedrich-Gauß-Str.

More information

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises

More information

GOM Optical Measuring Techniques. Deformation Systems and Applications

GOM Optical Measuring Techniques. Deformation Systems and Applications GOM Optical Measuring Techniques Deformation Systems and Applications ARGUS Forming Analysis ARGUS Deformation analysis in sheet metal and forming industry Forming Characteristics of Sheet Metals Material

More information

III. Cell destruction by freezing and cryoprobe development

III. Cell destruction by freezing and cryoprobe development III. Cell destruction by freezing and cryoprobe development 1 WHAT IS CRYOSURGERY? Cryoprobe Surface iceball formation Ice-ball Cryoprobe Cryosurgery of liver (Angular insertion) Cryosurgery of liver (Vertical

More information

FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE Std 1528-2003 and 1528a-2005. (Class II Permissive Change) SAR EVALUATION REPORT. For.

FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE Std 1528-2003 and 1528a-2005. (Class II Permissive Change) SAR EVALUATION REPORT. For. FCC OET BULLETIN 65 SUPPLEMENT C 01-01 IEEE Std 1528-2003 and 1528a-2005 (Class II Permissive Change) SAR EVALUATION REPORT For Glass Model: XEB Report Number: 13U14955-5A Issue Date: 4/15/2013 Prepared

More information

The tradescantia micronucleus bioassay:

The tradescantia micronucleus bioassay: Investigation of the mutagenicity of electromagnetic fields using the tradescantia micronucleus bioassay H. Lehmann 1, C. Pickl 2, M. Urech 3 1 Environment & Electromagnetic Compatibility, Swisscom Innovations,

More information

site monitoring Kit Site Monitoring Kit User Manual we prove it.

site monitoring Kit Site Monitoring Kit User Manual we prove it. site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series. Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series. 1 To discuss the design challenges of LED systems we look at the individual system components. A basic

More information

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living 2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use

More information

Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments

Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments Assessment of Human Exposure to Electromagnetic Radiation from Wireless Devices in Home and Office Environments Sven Kühn, Urs Lott, Axel Kramer, Niels Kuster Foundation for Research on Information Technologies

More information

Application Note, V1.0, 2008 AN2008-03. Thermal equivalent circuit models. replaces AN2001-05. Industrial Power

Application Note, V1.0, 2008 AN2008-03. Thermal equivalent circuit models. replaces AN2001-05. Industrial Power Application Note, V1.0, 2008 AN2008-03 Thermal equivalent circuit models replaces AN2001-05 Industrial Power Edition 2008-06-16 Published by Infineon Technologies AG 59568 Warstein, Germany Infineon Technologies

More information

SAR Distribution in Test Animals Exposed to RF Radiation

SAR Distribution in Test Animals Exposed to RF Radiation German Mobile Telecommunication Research Programme, July 25th, 2006 SAR Distribution in Test Animals Exposed to RF Radiation Verónica Berdiñas Torres, Andreas Christ, Niels Kuster IT IS Foundation, ETH

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

OVERVIEW OF STANDARD 7E & STANDARD 20

OVERVIEW OF STANDARD 7E & STANDARD 20 Standard for Thermal Transport Packaging Used in Parcel Delivery System Shipment 7E 2 010 ISTA 7E Usage Modes VERSION DATE OCTOBER 2010 Initial Release ISTA, Distributing Confidence, Worldwide ISTA 7-Series

More information

O C M III. Open Channel Flow Monitor

O C M III. Open Channel Flow Monitor O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this

More information

Calibration of Dallas sensors

Calibration of Dallas sensors Calibration of Dallas sensors Mariusz Sapinski INFN Sezione di Roma1 Roma, Italy (April 2006) 1. Objectives The goal of this work is to perform a calibration of Dallas sensors. Nine Dallas sensors are

More information

How To Understand The Safety Of A Cell Phone (Cell Phone)

How To Understand The Safety Of A Cell Phone (Cell Phone) Compliance Testing of Mobile Phones Masao Taki Tokyo Metropolitan University JAPAN Outline Exposure Standards/Guidelines Product Standard of MTE and Standard Procedures of Compliance Testing Some remarks

More information

Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements

Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction

More information

CONVECTION CURRENTS AND ANOMALOUS BEHAVIOUR OF WATER

CONVECTION CURRENTS AND ANOMALOUS BEHAVIOUR OF WATER CONVECTION CURRENTS AND ANOMALOUS BEHAVIOUR OF WATER Objective: To compare the thermal behaviour of water with that of other liquids, specifically alcohol and edible oil. To point out the anomaly of water

More information

Quick start: Panic Watch EU

Quick start: Panic Watch EU Quick start: Panic Watch EU Technical specs Normal operating voltage Frequency range Wireless Range 1x CR2032 3V battery 868.42 MHz Min 150 meters in a mesh network Basic operations - The Panic Watch can

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003) (Part # S-LIB-M003) The smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Weather Station.

More information

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012

SAR Test Report: Type Number FAD-3022012-BV; FCC ID PY7FD022012; IC 4170B-FD022012 1 (34) Report issued by an Accredited Laboratory Rapport utfärdad av ett ackrediterat laboratorium This laboratory is accredited to SS-EN ISO/IEC 17025 (SWEDAC accreditation no. 1761). SAR Test Report:

More information

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank

More information

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming

More information

Microwave Meter. Instruction Manual

Microwave Meter. Instruction Manual Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

TIE-32: Thermal loads on optical glass

TIE-32: Thermal loads on optical glass PAGE 1/7 1 Introduction In some applications optical glasses have to endure thermal loads: Finishing procedures for optical elements like lenses, prisms, beam splitters and so on involve thermal processes

More information

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured

More information

Transducer Mounting and Test Setup Configurations. Rick Bono The Modal Shop

Transducer Mounting and Test Setup Configurations. Rick Bono The Modal Shop Transducer Mounting and Test Setup Configurations Rick Bono The Modal Shop 1 Transducer Mounting Mechanical connection method Stud mount Adhesive mount Magnetic mount Press-fit friction mount Test parameter

More information

Peltier Application Note

Peltier Application Note Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you

More information

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient Microbiological Incubators Safe, easy and efficient Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new laboratory microbiological incubators is designed with

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling

DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE. E. Günther, S. Hiebler, H. Mehling DETERMINATION OF THE HEAT STORAGE CAPACITY OF PCM AND PCM-OBJECTS AS A FUNCTION OF TEMPERATURE E. Günther, S. Hiebler, H. Mehling Bavarian Center for Applied Energy Research (ZAE Bayern) Walther-Meißner-Str.

More information

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a

More information

Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment

Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment (Jan 2005) (Corr.1 Nov 2005) (Rev.1 Oct 2006) (Corr.1 Oct 2007) (Rev.2 Feb 2015) Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment 1. Scope 1.1 To specify the tests required to

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC 42.25 37 11 5.75 3.5 5.15 37.89 39.

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC 42.25 37 11 5.75 3.5 5.15 37.89 39. Product description Spotlights Downlights High-flux LED module Narrow colour temperature tolerance band Compact design Excellent thermal management 1 NTC for temperature control High-power LED in chip-on-board

More information

Certificate: 0000038506_01 / 29 April 2014

Certificate: 0000038506_01 / 29 April 2014 Test report: 936/21219899/C of 30 August 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 1.1 Approved application The tested AMS

More information

Using NTC Temperature Sensors Integrated into Power Modules

Using NTC Temperature Sensors Integrated into Power Modules Using NTC Temperature Sensors Integrated into Power Modules Pierre-Laurent Doumergue R&D Engineer Advanced Power Technology Europe Chemin de Magret 33700 Mérignac, France Introduction Most APTE (Advanced

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields

Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Federal Communications Commission Office of Engineering & Technology Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Additional Information for Evaluating

More information

Body SAR and EU. B. Derat

Body SAR and EU. B. Derat Body SAR and EU B. Derat Overview / Outline New Approach: Directive / Standards Current applicable standard IEC/EN 62209-2:2010 Tablet case study Future of EU body SAR testing Maintenance of IEC 62209-2

More information

FDA Guidelines for Magnetic Resonance Equipment Safety

FDA Guidelines for Magnetic Resonance Equipment Safety FDA Guidelines for Magnetic Resonance Equipment Safety Loren A. Zaremba, Ph.D. Center for Devices and Radiological Health Food and Drug Administration Outline I. Introduction II. Static Magnetic Field

More information

WSD130 SOLDERING STATION

WSD130 SOLDERING STATION NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch

More information

Lecture 9, Thermal Notes, 3.054

Lecture 9, Thermal Notes, 3.054 Lecture 9, Thermal Notes, 3.054 Thermal Properties of Foams Closed cell foams widely used for thermal insulation Only materials with lower conductivity are aerogels (tend to be brittle and weak) and vacuum

More information

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H) STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H) by Joseph F. Greenbeck, Jr. And Courtney W. Taylor INTRODUCTION The following procedure is to be used for the maintenance and calibration

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

PTU Series Ultrahigh-Purity Pressure Transducers

PTU Series Ultrahigh-Purity Pressure Transducers PTU Series UltrahighPurity Pressure Transducers User s Manual The Swagelok PTU series pressure transducer provides electronic monitoring of system pressure for ultrahighpurity applications. The PTU series

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

Assembly of LPCC Packages AN-0001

Assembly of LPCC Packages AN-0001 Assembly of LPCC Packages AN-0001 Surface Mount Assembly and Handling of ANADIGICS LPCC Packages 1.0 Overview ANADIGICS power amplifiers are typically packaged in a Leadless Plastic Chip Carrier (LPCC)

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

3mm Photodiode,T-1 PD204-6C/L3

3mm Photodiode,T-1 PD204-6C/L3 3mm Photodiode,T-1 Features Fast response time High photo sensitivity Small junction capacitance Pb free This product itself will remain within RoHS compliant version. Description is a high speed and high

More information

Sanitary and CIP Toroidal Sensor

Sanitary and CIP Toroidal Sensor Instruction Sheet PN 51A-225/rev.I December 2010 Model 225 Sanitary and CIP Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Selected Radio Frequency Exposure Limits

Selected Radio Frequency Exposure Limits ENVIRONMENT, SAFETY & HEALTH DIVISION Chapter 50: Non-ionizing Radiation Selected Radio Frequency Exposure Limits Product ID: 94 Revision ID: 1736 Date published: 30 June 2015 Date effective: 30 June 2015

More information

Optical Power Meter. Specification & User Manual

Optical Power Meter. Specification & User Manual Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

Domain decomposition techniques for interfacial discontinuities

Domain decomposition techniques for interfacial discontinuities Domain decomposition techniques for interfacial discontinuities Geordie McBain Institut Jean le Rond d Alembert December 5, 2012 Connexion and substructuring Two ways to look at domain decomposition Decomposing

More information

Throttle Body Fuel Injection

Throttle Body Fuel Injection Throttle Body Fuel Injection Initial Calibration of the TBI Disclaimer The author of this presentation assumes NO responsibility for information provided causing the owner to modify or alter their motorhome

More information

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz J. Klima, R. Ščehovič Department of Physics, Faculty of Natural Sciences, University of Mathias Bel, Tajovského

More information

Determination of the heat storage capacity of PCM and PCM objects as a function of temperature

Determination of the heat storage capacity of PCM and PCM objects as a function of temperature Determination of the heat storage capacity of PCM and PCM objects as a function of temperature E. Günther, S. Hiebler, H. Mehling ZAE Bayern, Walther-Meißner-Str. 6, 85748 Garching, Germany Outline Introduction

More information

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching) INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight

More information

Thermal Effects of Mobile Phones

Thermal Effects of Mobile Phones Thermal Effects of Mobile Phones S. Kassimi 1, A. ELfadl, S. Bri 3, A. Nakheli 4, M. Habibi 5, M. Ben Ahmed 6 Systems and Telecommunications Engineering Decision Laboratory,Ibn Tofail University, Faculty

More information

SOLAR I-V Rel. 1.01 20/07/10

SOLAR I-V Rel. 1.01 20/07/10 PV single phase certifier and I-V curve checker Pag 1 of 5 1. SOLAR I-V MAIN FEATURES SOLAR I-V: use as PV certifier SOLAR I-V performs all tests on Single phase PV plants by using of SOLAR-02 remote unit

More information

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction Module 1 : Conduction Lecture 5 : 1D conduction example problems. 2D conduction Objectives In this class: An example of optimization for insulation thickness is solved. The 1D conduction is considered

More information

How to measure absolute pressure using piezoresistive sensing elements

How to measure absolute pressure using piezoresistive sensing elements In sensor technology several different methods are used to measure pressure. It is usually differentiated between the measurement of relative, differential, and absolute pressure. The following article

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

Machine Tool Inspection & Analyzer solutions

Machine Tool Inspection & Analyzer solutions Machine Tool Inspection & Analyzer solutions Introduction IBS Precision Engineering machine tool inspection series offers a range of products to provide peace of mind and control to machine operators by

More information

Chlorophyll Content Meter. CCM-200 plus

Chlorophyll Content Meter. CCM-200 plus Chlorophyll Content Meter CCM-200 plus www.apogeeinstruments.com techsupport@apogeeinstruments.com 435.792.4700 Fax: 435.787.8268 Table of Contents Unit Overview...2 About the Instrument... 4 How It Works...

More information

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria

EUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria EUROPEAN STANDARDS FOR FLAME RESISTANT PERSONAL PROTECTIVE CLOTHING Alexander Gstettner, Lenzing AG Austria W a t e r How are the standards organized? A 1 Testing Methods Standards specifiying performance

More information

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS HIGHLIGHTS 3D Real Time Tracking Quality Control & Inspection Reverse Engineering ID 2D 3D Scanning PRODUCTS PRECI 3D TRACK PRECI 3D SCAN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRECI

More information

Certificate: 0000038506 / 20 August 2013

Certificate: 0000038506 / 20 August 2013 Test report: 936/21219899/B of 28 March 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 1.1 Approved application The tested AMS

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

Hand Gestures Remote Controlled Robotic Arm

Hand Gestures Remote Controlled Robotic Arm Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 3, Number 5 (2013), pp. 601-606 Research India Publications http://www.ripublication.com/aeee.htm Hand Gestures Remote Controlled

More information

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,

More information

6 H2O + 6 CO 2 (g) + energy

6 H2O + 6 CO 2 (g) + energy AEROBIC RESPIRATION LAB DO 2.CALC From Biology with Calculators, Vernier Software & Technology, 2000. INTRODUCTION Aerobic cellular respiration is the process of converting the chemical energy of organic

More information

Everline Module Application Note: Round LED Module Thermal Management

Everline Module Application Note: Round LED Module Thermal Management Everline Module Application Note: Round LED Module Thermal Management PURPOSE: Use of proper thermal management is a critical element of Light Emitting Diode (LED) system design. The LED temperature directly

More information

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources PROVISIONAL The Source for Calibration Professionals Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources The NEW Advanced Range of Portable Temperature Calibrators Advanced Range Isotech

More information

Figure 1 - Unsteady-State Heat Conduction in a One-dimensional Slab

Figure 1 - Unsteady-State Heat Conduction in a One-dimensional Slab The Numerical Method of Lines for Partial Differential Equations by Michael B. Cutlip, University of Connecticut and Mordechai Shacham, Ben-Gurion University of the Negev The method of lines is a general

More information

22.302 Experiment 5. Strain Gage Measurements

22.302 Experiment 5. Strain Gage Measurements 22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

Zero Width Glass Cutting with CO 2 Laser

Zero Width Glass Cutting with CO 2 Laser Zero Width Glass Cutting with CO 2 Laser Mohammed Naeem GSI Group, Laser Division Cosford Lane, Swift Valley Rugby mnaeem@gsig.com Introduction Laser cutting of glass in not a novel technique, excellent

More information

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

Determination of Thermal Conductivity of Coarse and Fine Sand Soils Proceedings World Geothermal Congress Bali, Indonesia, - April Determination of Thermal Conductivity of Coarse and Fine Sand Soils Indra Noer Hamdhan 1 and Barry G. Clarke 2 1 Bandung National of Institute

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application.

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application. Diode rectifiers are ideal solutions for automotive electronic power line protection and have several important parameters for these applications, including: Forward current, repetitive reverse voltage,

More information

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510

User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510 User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget ACE Automated Soil CO 2 Exchange System Automated operation Automatically exposes soil area between measurements CO 2 analyser in chamber Highly accurate CO 2 IRGA housed directly inside soil chamber assembly

More information

Trace Dissolved Oxygen Sensor

Trace Dissolved Oxygen Sensor Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION

More information

DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL

DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL BRAZILIAN INDUSTRY NATIONAL PRODUCT Web Table of content: 1- Product description 2- Technical specifications of the product 3- Product parts 4-

More information

LP02 Solar Radiation sensor Compliant with ISO and WMO standards

LP02 Solar Radiation sensor Compliant with ISO and WMO standards LP02 Solar Radiation sensor Compliant with ISO and WMO standards LP02 manual version 0609 Edited & Copyright by: Hukseflux Thermal Sensors http://www.hukseflux.com e-mail: info@hukseflux.com Warning: Warnings

More information

Inventory Control. Inventory Control Tank & Silo Weighing

Inventory Control. Inventory Control Tank & Silo Weighing Inventory Control Tank & Silo Weighing Gravimetric level control is one of the most accurate inventory control methods available. Its high degree of accuracy makes it particularly helpful when measuring

More information

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184 EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49

More information