APPLICATION GUIDE MINI PRODUCT GUIDE



Similar documents
LIGHTING CONTROL SYSTEM

High Bay Occupancy Sensor Selection Guide

Code Compliance Commercial Application Guide

Sensor Product Guide. Smart Sensing Control Solutions

Lighting Management solutions

ENERGY SAVING SOLUTIONS:

Dual Technology Ceiling Mount Sensor

GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

Reference Design. conference rooms

RETROFIT LIGHTING & CONTROLS SOLUTIONS. Automotive Dealerships

Catalog Number. Notes

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Lighting Controls for Energy Efficient Government Buildings

DuroSite TM High Bay Lighting

Energy Efficiency for Businesses: An Overview of Best Practices to Help Reduce Energy Costs

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:

Installation Instructions

General Lighting Recommendations

C-Bus Solutions. Complete commercial control. Make the most of your energy SM

in a new light. Occupancy sensors and sensor lights. Sleek new styling and more features than ever before.

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Industrial Linergy LED

Product Catalogue August Energy management Switches and controls

Lighting Control in the Office Space

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System

SMART SENSOR COLLECTION

Trinchero Family Estates Building: Operation User s Guide

TABLE Lighting Power Densities Using the Space-by-Space Method(continued) TABLE Lighting Power Densities Using the Space-by-Space Method

OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

On/Off Relay Switch and 3-Way Switch Kit

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Building Technologies

A1.5 Classroom Standards

LOS 2500 SUPER CEILING SENSOR. Installation Manual

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Wireless Alarm system s manual

Solid State Timers Type F

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

SECTION LOW VOLTAGE LIGHTING CONTROLS

WHAT S NEW IN THE 2013 CODE?

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

Lutron High Bay Fixture Solutions

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

T7560A,B,C Digital Wall Module

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

Product Specifications Dialog System

LED DIMMING A HELPFUL GUIDE...

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

16551 EMERGENCY LIGHTING SYSTEMS. C. Refer to Cornell Design & Construction Standard for Emergency Power Systems.

Lighting Incentives. Application and Instructions. Questions

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Product and Application Description

GTEC transfer switch open transition

Equipment Specifications Rebate/Unit Rules

EQUIPMENT SPECIFICATIONS

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

SECTION DETECTION AND ALARM

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

GSM ALARM SYSTEM USER MANUAL

Wireless Lighting Control. On/Off/Dim. Dimmer Switch.

LED MOTION ACTIVATED FLOOD LIGHT

LIGHTING and LIGHTING SYSTEMS

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

INSTALLATION INSTRUCTIONS

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

Fire detection equipment

Office of Integrated Security Systems Longwood University Camera System Standards

How To Make A Commercial Detector

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Basics of Dimming. ISC Learning Centre

Guide to new, energy-efficient lighting technologies for your business

New XUY roller sensors

STRATO LED Drivers 70W, Single output

EBDSPIR-PRM, EBDSPIR-PRM-IP

How To Use A Lutron Power Supply

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

CA Title Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014

Evolve LED Garage Light

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Electromagnetic Locking

Surveillance, Security & CCTV: A Buyer s Guide

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Connecting the Channel A

Evolve LED Area Light

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

Transcription:

MINI PRODUCT GUIDE

BETTER PERFORMANCE THROUGH ADVANCED TECHNOLOGY 100% Digital Passive Infrared (PIR) Detection Dual Technology Detection utilizing Microphonics Contractor Friendly Wiring Features MICROPHONICS TECHNOLOGY Sets The New Standard For Occupancy Detection In Rooms With Obstructions PASSIVE DUAL TECHNOLOGY [ PIR/MICROPHONICS ] Sensors both see occupant motion and hear the sounds they make More effective than sensors using two technologies that only detect motion (e.g., Ultrasonic/PIR) Immune from conditions that typically cause false ons (e.g., persons walking by a space or nonoccupant motion within a space) 100% acoustically passive - no high frequency transmissions, no potential for interference, & none of the headaches common with other technologies

KEY ENERGY CODE REQUIREMENTS ASHRAE/IES 90.1-2010 applies to any new construction projects and retrofit projects involving alteration of 10% of connected lighting load. All lighting systems must be turned OFF when not in use*. Occupancy sensors are the easiest way to comply. Spaces must also have a lighting control device that is either: Manual-On or Auto- On to 50% (via either Bi-Level Switching or Dimming*). Both of these methods necessitate a manual control. The following spaces require the installation of an occupancy sensor (or a timer switch) that turns lighting off within 30 minutes after the last occupant leaves the space: All offices 250 ft 2 or less Restrooms Classrooms Lecture halls Conference and meeting rooms Training rooms Employee lunch & break rooms All storage & supply rooms between 50-1000 ft 2 Rooms used for document copying & printing Dressing, locker, and fitting rooms Many enclosed spaces must have controls that reduce the power level by 30-70% in addition to turning off all lighting (this generally requires either control for Bi-Level Switching or Dimming)*. MADE IN USA FROM IMPORTED PARTS *Note: exceptions apply, refer to code for all applicable details

WALL SWITCH SENSORS Quick & Easy Energy Savings PIR - Private Restrooms, Copy Rooms, Closets DUAL TECH - Private Offi ce, Restroom with Stalls, Small Meeting Rooms Device accommodates powering over ground or neutral connection (patent pending); converts in seconds 100% digital PIR detection & photocell standard Small motion detection to 20 ft & large motion >36 ft Ruggedized assembly, vandal resistant lens standard Compatible w/ LEDs, Fluorescents, CFLs, & Incandescents Fully meets NEC 2011 Section 404.2C neutral requirements CONVERSION FROM GROUND ONLY (NO NEUTRAL) TO NEUTRAL WIRING: STEP 1: Remove yellow label. STEP 2: Loosen Screws & Remove Metal Link. STEP 3: Connect Ground to Green Screw & Neutral to Silver Screw. SCAN QRCODE TO ACCESS DATASHEET WITH ADDITIONAL OPTIONS (E.G. COLOR, NIGHT LIGHT) WSX WH WSX VA WSX PDT WH WSX PDT VA WSX 2P WH WSX PDT 2P WH PIR, Auto On (default) or Manual On PIR, Manual On (Vacancy) Only Dual Tech, Auto On (default) or Manual On Dual Tech, Manual On (Vacancy) Only PIR, Dual Relay (Pole 1: Auto On; Pole 2: Manual On) Dual Tech, Dual Relay (Pole 1: Auto On; Pole 2: Manual On)

LOW VOLTAGE SENSORS Ideal for Spaces Requiring Multiple Sensors Open Offi ce, Classroom, Conference Room, Large Offi ce, Corridor, Large Storage Area, Lobby Small motion sensors best for areas where people are stationary Large motion sensors best for areas with walking traffi c Dual Tech detection required for areas with obstructions No sensitivity adjustments required - install and forget Simple push-button time delay adjustment - no tools required Utilizes power pack (PP20) to switch entire circuit Convenient mounting without junction boxes: - 360 ceiling enclosure (pictured above, left) surface mounts directly to ceiling tiles - 120 wide view enclosure (pictured above, right) directly mounts in a corner or to a wall OPTIONS Low Voltage Auxiliary Relay Photocell Override 0-10 VDC Dimming Low Temp / High Humidity SCAN QRCODE TO ACCESS DATASHEET WITH ADDITIONAL INFORMATION COVERAGE AREA* CM 9 360 Small Motion, PIR, Ceiling Mount CM PDT 9 360 Small Motion, Dual Tech, Ceiling Mount ~12 ft (3.66 m) radius (~500 ft 2 ) CM 10 360 Large Motion, PIR, Ceiling Mount CM PDT 10 360 Large Motion, Dual Tech, Ceiling Mount ~24 ft (7.32 m) radius (~2000 ft 2 ) WV 16 120 Small Motion, PIR, Corner Mount Small motion ~40 ft (12.19 m) WV PDT 16 120 Small Motion, Dual Tech, Corner Mount Large motion ~70 ft (21.34 m) HW 13 Hallway, Large Motion, PIR, Wall Mount ~70 ft (21.34 m) when mounted at 7 ft (2.13m) *AT 9 FT MOUNTING HEIGHT POWER/RELAY PACKS Provides Low Voltage Power & Switches Lighting Powers up to 14 low voltage sensors & wall stations Rated for 20A lighting or receptacle loads SCAN QRCODE TO ACCESS DATASHEET WITH ALL ORDERING INFORMATION PP20 Power/Relay Pack (120/277 VAC)

DAYLIGHT CONTROLLERS Maximize Energy Savings Through Daylight Harvesting Meets daylight control code requirements for spaces with signifi cant daylight contribution from windows or skylights Interfaces with low voltage sensors & wall controls Available in on/off or auto-dimming (0-10 VDC) versions Self-Calibrating - capable of fi nding optimum set-point Easy to Apply - deploy standalone or combine with occupancy sensors SCAN QRCODE TO ACCESS DATASHEET WITH ALL ORDERING INFORMATION CM ADC CMRB ADC CM PC CMR PC Dimming Photocell, Low Voltage, 0-10 VDC, Ceiling Mount Dimming Photocell, Line Voltage, 0-10 VDC, Fixture Mount On/Off Photocell, Low Voltage, Ceiling Mount On/Off Photocell, Line Voltage, Ceiling Mount LOW VOLTAGE SWITCH Interfaces with Sensors to Enable Full Code Compliance Provides code-compliant manual control when applied with low voltage occupancy sensors and relay packs Alternative usage as override switch for auto-on applications Single gang enclosure with 1 or 2 on/off switches Soft-touch tactile control Optional dual manual-on operation 3X option enables unit for multi-way confi gurations (i.e., 3-way, 4-way, etc.) Optional 0-10 VDC dimming control SCAN QRCODE TO ACCESS DATASHEET WITH ADDITIONAL OPTIONS (E.G. COLOR) SPODM SA WH SPODM 2P WH SPODM SA D WH SPODM WH Sensor Interface Switch Manual On (default) Dual Sensor Interface Switch Switch 1 Manual On / Switch 2 Auto On Sensor Interface Switch & 0-10 VDC Dimming Control - Manual On Sensor Interface Switch Auto On (default)

FIXTURE MOUNT SENSORS Interchangeable Lenses for Maximum Versatility Warehouses, Distribution Centers, Gymnasiums, Industrial Spaces Integrated mounting bracket drops lens down 3 from chase nipple - no bracket accessory required Single or dual relay versions Power options for MVOLT/HVOLT & single/two-phase Photocell and 0-10 VDC dimming options Highly confi gurable ordering options FOUR INTERCHANGEABLE LENSES #6 LENS High Mount #10 LENS Low Mount #50 LENS Aisleway #9 LENS Small Motion 15 to 45 ft (4.57 to 13.72 m) mounting height 7 to 15 ft (2.13 to 4.57 m) mounting height bidirectional range of ~1.2 x mounting height 8 to 15 ft (2.44 to 4.57 m) mounting height EASY LENS CHANGE SCAN QRCODE TO ACCESS DATASHEET WITH ALL ORDERING INFORMATION LSXR 610 LSXR 610 HL LSXR 610 P LSXR 610 ADC LSXR 610 2P High Mount 360 Sensor with Accessory Low Bay Lens High/Low Mount 360 Sensor with High/Low Dimming Control Option High/Low Mount 360 Sensor with On/Off Photocell Option High/Low Mount 360 Sensor with Auto Dimming Photocell Option High/Low Mount 360 Sensor with Dual Relay Control

APPLICATION GUIDE The below table lists recommended sensor solutions for common spaces. Information on the full line of Sensor Switch products is available in the full product catalog or online at sensorswitch.com. SOLUTION OPTIONS SMALL OFFICE/MEETING/BREAK ROOM WALL SWITCH SENSOR - MANUAL ON WALL SWITCH SENSOR W/ DUAL RELAYS (POLE 1 AUTO ON, POLE 2 MANUAL ON) CEILING 360 SENSOR w/ TWO RELAY PACKS AND SWITCH OPEN OFFICE CEILING 360 SENSOR w/ TWO RELAY PACKS & SWITCH CORRIDOR/HALLWAY SHORT STRAIGHT HALLWAYS - DUAL HALLWAY SENSORS LONGER CORRIDORS WITH ALCOVES/VESTIBULES - CEILING 360 SENSOR L-SHAPED - HALLWAY SENSOR & CEILING 360 SENSOR WSX PDT VA WH WSX PDT 2P WH CM PDT 9, PP20 (QTY 2) & SPODM 2P WH CM PDT 9 (~1 PER 30 X 30 FT AREA), PP20 (QTY 2) & SPODM 2P WH HW 13 (QTY 2) & PP20 (QTY 1) (OPTIONAL WV BR CEILING MOUNT BRACKET) CM 10 (1 PER ~50 FT) & PP20 (1 PER CIRCUIT OR SWITCH LEG) HW 13, CM 10, & PP20 PRIVATE RESTROOM/CLOSET WALL SWITCH SENSOR CEILING 360 SENSOR WSX WH CM 9 & PP20 PUBLIC RESTROOM WALL SWITCH SENSOR WALL SWITCH SENSOR w/ DUAL RELAYS FOR LIGHT & FAN CEILING 360 SENSOR WSX PDT WH WSX PDT 2P WH CM PDT 9 & PP20 CLASSROOM WIDE VIEW SENSOR CEILING 360 SENSOR WV PDT 16, PP20 (QTY 2), & SPODM 2P WH CM PDT 10, PP20 (QTY 2), & SPODM 2P WH Form 1412.007 1.800.PASSIVE www.sensorswitch.com 2014 Acuity Brands, Inc. All Rights Reserved.