APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS



Similar documents
Container Management for Hazardous Waste Generators Technical Guidance Document HW-2005-G1

Regulated Waste Storage

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

Satellite Accumulation Areas Large Quantity Generators June 2009

General Fire Code Requirements Within Commercial Tenant Spaces

Name Of Occupancy Date. Yes No Describe

Monthly Warehouse Inspection Checklist

How To Check If A Building Is Safe For A Disabled Person

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Title: Aircraft Parking

Hazardous Waste Determination and Management Plan

Spill Control Prevention Plan (SCPP)

EXHIBIT A SCOPE OF WORK

Contingency Plan. Community College of Denver - Auraria Campus Facility Name

SAFETY SELF-INSPECTION PROGRAM

Six Monthly Servicing of Fire Extinguisher on Commercial Vessels.

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

North Carolina State University Emergency Facilities Closure Checklist- Part I

ADMINISTRATIVE SERVICES MANUAL

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

External Visual Inspection Form

Sample Written Program. For. Flammable Liquids

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

Contingency Plan. Facility Name

Inspection Item COMMENTS

Laboratory Safety and Environmental Health Assessment Program

RISK MANAGEMENT QUARTERLY BUILDING REPORT Fire Safety Self -Inspection Checklist

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

Hazardous Waste Accumulation, Storage, & Labeling

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

ENGINEERING RELEASE MODEL: LEARJET MODEL 20 AND 35/36 SERIES DRAWING. NO.: SHEET: 1 OF 1

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

PROCESS DESCRIPTION ATTACHMENT

Home Warranty Inspection Report

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

Contingency Plan Template. Hazardous Materials and Waste Management Division (303)

PCB STORAGE. 1) 2-drum unit (4 x 2 x 4 ) 2) 4-drum unit (4 x 4 x 4 ) 3) 8-drum unit (8 x 4 x 4 ) 4) 16-drum unit (8 x 8 x 10 )

HEAD HARNESS & BUCKELS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

Suffolk County Department of Health Services. Division of Environmental Quality

Notes. Material 1. Appropriate Flammable Liquids

Inspecting to a higher standard.

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

Disaster Prevention and Protection Checklist

Radioactive Waste Storage Facility and Tank System Design Criteria Standards

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

Evaluate, Clean, and Tune Guidance

ATTACHMENT 1-9 CHWSF CONTAINER MANAGEMENT

Working Copy WP 05-WH1401. Revision 4. 6-Ton Electric Forklifts 74-H-010B. Technical Procedure EFFECTIVE DATE: 01/04/06. John Guy APPROVED FOR USE

Rutgers Environmental Health and Safety

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

BP WIND ENERGY POLICIES AND PROCEDURES

Minnesota State Department of Public Safety

Waste Management Log Book

To: All Shipowners, Ship Managers, Ship Masters and Classification Societies

HVAC Design Requirements

Injury & Illness Prevention Program (IIPP)

Level I Inspection Guidance Document 2014

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Boiler and Burner Cleaning and Servicing Specifications

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

Commercial Roof Management

healthy homes assessment

4-Point Inspection Personal Lines (Edition 9/2012)

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Walking and Working Surface Checklist:

WARNING! Failure to follow these inspection procedures can cause personal injury and property damage.

Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Waste Management

Commercial Fire Inspections

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

This page left intentionally blank

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

PRE-PURCHASE INSPECTION REPORT

Office of the Fire Marshal MAINTENANCE OF SMOKE ALARMS OFM-TG July 1998 GUIDELINE

SECURITY VULNERABILITY CHECKLIST FOR ACADEMIC AND SMALL CHEMICAL LABORATORY FACILITIES

Forklifts, Battery Charging and Material Handling

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Self-Home Inspection Checklist

Monthly Inspection Checklists

Environmental Standard Operating Procedure Originating Office: MCAS Miramar Environmental Management Department

OREGON FIRE CODE Interpretations and Technical Advisories

A Self-Audit of Your Current Campus Security Systems

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Safety Inspection Checklist

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

LABORATORY SAFETY INSPECTION CHECKLIST

OSHA Remove impacted systems and components. Inspect systems prior to use.

EAST STROUDSBURG BOROUGH RESIDENTIAL RENTAL INSPECTION CHECK LIST

ATTACHMENT 12 CONTAINERS

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Winnipeg Fire Department Fire Prevention Branch

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Petroleum Storage Tank Compliance 101

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Transcription:

APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS Pueblo Chemical Depot

Pueblo Chemical Depot (This page intentionally left blank.)

PCAPP EDS Daily (When in Use) Operational Inspection Checklist EXAMPLE Inspected By: Signature: Environmental Enclosure 1 or 3 Date: Time: No. Activity EDS Containment Vessel (Interior and Exterior) 1 Are there any spills, leaks, or liquids in the area? 2 Does the exterior tubing and valves show any signs of corrosion, leakage, or other physical damage, such as tears, stresses, gouges, rips, cracks, loose screws, etc.? [Subpart CC] 3 Does the interior show any signs of physical damage that would impair treatment capability? 4 Are the Waste Transfer Subsystem hoses/connections from the vessel door to liquid waste containers in good condition? Are the sealing surfaces of the vessel clean and in good condition? [Subpart CC] EDS Waste Transfer Subsystem 5 Are containers in good condition, i.e., no signs of deterioration, rust, corrosion, or leaking? [Subpart CC] 6 Is there adequate aisle spacing between containers and walls of the Environmental Enclosure? 7 Does the secondary containment for waste containers show signs of cracks, flaking, chips, gouges, or obvious wear or deterioration? [Subpart CC] 8 Does the secondary containment for waste containers have signs of drips, spills, or leaks or any accumulated liquids? EDS Trailer/Skid Secondary Containment Pan 9 Does secondary containment pan show liquids, leakage, or signs of corrosion, or other physical damage, such as cracks, gaps, or holes? Yes, No, or Not Applicable (NA)? Corrective Action Required? If Yes, provide detail below. Enclosure Floor Area Secondary Containment Systems 10 Does the enclosure floor area secondary containment berm show signs of cracks, flaking, chips, gouges, or obvious wear or deterioration? Are there signs of drips, spills, or leaks or any accumulated liquids? EDS Lift Assist IF THE LIFT ASSIST IS NOT BEING USED, DO NOT COMPLETE THIS SECTION. 11 Has the lift assist unit been visually inspected to confirm that the unit is marked with load rating and the date of next inspection? Environmental Enclosures 12 Is the structural integrity of each environmental enclosure showing signs of rips, tears, holes, gaps, or other deterioration? Presence of leaks? Pueblo Chemical Depot Appendix 2-3-1 March 5, 2015

Comments/Discrepancies/Remedial Work Required: Date Corrective Action Completed: Verified by: Pueblo Chemical Depot Appendix 2-3-2

PCAPP EDS Daily Inspection (When in Use) EXAMPLE Inspected By: Signature: Date: Time: No. Activity Yes, No, or Not Applicable (NA)? Corrective Action Required? If Yes, provide detail below. Communication Equipment 1 Are landline telephones, cellular telephones, hand-held radios or other communication equipment present and operable? 2 Is closed-circuit television operable and are visual clarity/tilt, pan, and zoom functions acceptable? 3 Has the integrity of audible/visual alarm been checked? Personnel Decontamination Station 4 Is appropriate and adequate decontamination solution present? Is PDS easily accessible? Is PDS equipment present and operable? Spill Kits and Emergency Response Equipment 5 Do Spill Kits contain sufficient inventory? Are items in good condition and within expiration dates (as applicable)? 6 Is emergency response equipment such as shovels, brooms, overpacks, present onsite, in sufficient quantities and in good condition to support response actions? Monitoring (MINICAMS and DAAMS) 7 Are monitors in good physical condition? Operating properly? Are diagnostic indicators operating? 8 Are sample lines and connections in good condition? Is heat trace functional? Proper ventilation for exhaust? 9 Was chemical agent challenge test and calibration conducted? Boiler/Chiller Container Subsystem 10 Perform visual inspection of components. Is steam generator in good physical condition? Is any damage present? 11 Are the flowmeters and the controls mounted on the small skid functioning and operable? Pueblo Chemical Depot Appendix 2-3-3 March 5, 2015

Comments/Discrepancies/Remedial Work Required: Date Corrective Action Completed: Verified by: Pueblo Chemical Depot Appendix 2-3-4

PCAPP EDS Site Monthly Inspection EXAMPLE Inspected By: Signature: Date: Time: No. Activity Yes, No, or Not Applicable (NA)? Corrective Action Required? If Yes, provide detail below. Fire Extinguisher 1 Are fire extinguishers present and operable? Is there adequate gauge pressure? Is the equipment within the service date? Emergency Generators 2 Start generators; check voltage current and frequency output regularity and filter differential pressure. Are units operable? Security 3 Is fencing of good integrity; any intrusion, or obstruction by vegetation or other damage? 4 Are warning signs present and legible? Comments/Discrepancies/Remedial Work Required: Date Corrective Action Completed: Verified by: Pueblo Chemical Depot Appendix 2-3-5 March 5, 2015

PCAPP EDS Site CSU H1102 EXAMPLE ANNUAL INSPECTION Name of Inspector: Date and Time of Inspection: CSU H1102 Carbon Filtration System Inspection Items Has the validation been conducted in accordance with PCD SOP PU-0000-R-491? Results Yes or No Corrective Action Required? Yes or No [If Yes, Provide Details Below] FOR CORRECTIVE ACTIONS: PROVIDE DESCRIPTION OF CORRECTIVE ACTION(S) AND DATE(S) COMPLETED BELOW. Pueblo Chemical Depot Appendix 2-3-6

PCAPP EDS Site CSU H1102 and H1103 EXAMPLE WEEKLY INSPECTION Name of Inspector: CSU: Date and Time of Inspection: Containers Inspection Items Are munition pallets or containers or signs in area labeled with the words Hazardous Waste, description of contents, applicable waste codes and/or DOT label or wording indicating primary hazard, and accumulation start date? Are waste containers stacked ONLY 1 high on containment pan? (Must not be more than 1 high) Are containers in good condition (i.e., show no signs of deterioration, rust, corrosion, or signs of leaks)? [Subpart CC] Are there any visible cracks, holes, gaps, or open spaces in the interior of the container when cover and closure devices are secured in the closed position? [Subpart CC] Are containers securely closed (except when adding or removing wastes)? [Subpart CC] Does any container require repairs? If yes, defect must be repaired or container replaced within 5 days of finding. [Subpart CC] Are storage area warning signs present and visible? Is adequate aisle space maintained in area to allow unobstructed movement of personal and safety/response equipment? Has inventory been verified to be within the permitted capacity for permitted storage? Results Yes or No Corrective Action Required? Yes or No [If Yes, Provide Details Below] Pueblo Chemical Depot Appendix 2-3-7

Secondary Containment (Pallets) Inspection Items Does portable secondary containment pan show signs of cracks, holes, gouges, tears, excessive wear, or other physical damage? Does portable secondary containment pan show signs of drips, leaks, or spills? Are any accumulated liquids present? CSU Floor Area Is CSU floor in good condition without visible cracks or accumulated liquids? Have general areas been inspected for signs of leakage? Is communication system available and functioning? (e.g., radio) Are emergency response/spill kit items present and in sufficient supply? Are fire extinguisher and eyewash present and operable? Are igloo entry/exit doors functioning properly (free of damage, closes and locks)? Roll-Off Containers (CSU H1103 only) Are containers in good condition, i.e., no signs of deterioration, corrosion, rust, or leaks? Is container properly labeled? Is container covered and kept closed except when adding waste? [Subpart CC] Are all components (i.e., door hinge, latch, shaft, rollers, safety chain, ladder) present and functioning properly? Is a liner present? Is the container locked when not in use? Results Yes or No Corrective Action Required? Yes or No [If Yes, Provide Details Below] Pueblo Chemical Depot Appendix 2-3-8

FOR CORRECTIVE ACTIONS: PROVIDE DESCRIPTION OF CORRECTIVE ACTION(S) AND DATE(S) COMPLETED BELOW. Pueblo Chemical Depot Appendix 2-3-9

PCAPP EDS Site CSU H1102 and H1103 EXAMPLE MONTHLY INSPECTION Name of Inspector: CSU: Date and Time of Inspection: Inspection Items CSU Carbon Filtration System (CSU H1102 ONLY) Is the carbon filtration system adequately clean and in good condition, and free of visible damage or deterioration that may affect performance? Are vents clean and free of visible damage or significant deterioration? Are exterior and interior screens intact and dampers properly positioned? CSU (Exterior) Are security, warning signs, doors, locks, fire extinguisher, door vent, rear vent properly placed and operational? Is area clear of debris and vegetation? Results Yes or No Corrective Action Required? Yes or No [If Yes, Provide Details Below] FOR CORRECTIVE ACTIONS: PROVIDE DESCRIPTION OF CORRECTIVE ACTION(S) AND DATE(S) COMPLETED BELOW. Pueblo Chemical Depot Appendix 2-3-10

PCAPP EDS SITE SEMI-ANNUAL Lightning Protection System (LPS) Inspection Sheet- Visual Inspection Facility Inspector: Date: Identify Area: (ex. Environmental Enclosure, Personnel Decontamination Station, or Mobile Analytical Platform) **Corrective Action Inspect LPS components for the following: Y/N [If Yes, Provide Details Below] Comments 1. Components broken or in need of repair? 2. Are there any loose connections? 3. Components free of corrosion? (Discoloration not considered corrosion) 4. Components free of breaks, cuts, and damage that will affect equipment integrity? 5. Bonding straps have more than 50% of wire strands broken? 6. Components weakened by vibration (e.g., wind)? 7. Are all components securely fastened to their mounting surfaces, including down conductors? 8. Are all ground conductors and terminals (visible portions) intact (e.g., not severed)? 9. Are there visual indications of damage to surge suppression (overvoltage) devices, if present? 10. Is there evidence of lightning strike damage that has degraded the integrity of the system? 11. Components protected against accidental mechanical displacement? 12. Have there been additions or alterations to the protected facility that would require additional protection or testing? References: PCD RCRA Renewal Permit, August 2013; DA Pam 385-64, Lightning Protection. LPS must be visually inspected semi-annually, including surge protection devices (SPDs). ** If the deficiency cannot be corrected immediately, the LPS inspection personnel shall record the deficiency and notify the installation safety office. If the LPS protects an ammunition or explosive storage structure, the custodian of the contents shall be notified (DA Pam 385-64). Pueblo Chemical Depot Appendix 2-3-11 March 5, 2015

Additional Comments/Discrepancies/Remedial Work Required: Date Corrective Action Completed: Verified by: Pueblo Chemical Depot Appendix 2-3-12

PCAPP EDS SITE Lighting Protection System (LPS) Inspection Sheet Electrical Inspection Inspector (Print): Signature: Ohmmeter S/N: Date: Time: Date: Equipment: 1. PANEL (IDS BOX) 2. CONDUIT ENTERING IGLOO 3. PANEL (ELECTRIC S/W BOX) 4. PANEL (SERVICE BOX) 5. PANEL (SERVICE BOX)* 6. UPPER HINGE 7. LOWER HINGE 8. UPPER ARM 9. LOWER ARM 10. SECURITY PLATE 11. DOOR 12. DOOR VENT 13. LIGHT BRACKET 14. AERIAL #1 15. AERIAL #2 16. AERIAL #3 17. AERIAL #4 18. AERIAL #5 (VENT) Ohmmeter Readings (ohms): CSU H1102 CSU H1103 EE1 EE2 ESM1 ESM2 Pass/Fail: Pueblo Chemical Depot Appendix 2-3-13

Ohmmeter Readings (ohms): Equipment: CSU H1102 CSU H1103 EE1 EE2 ESM1 ESM2 19. REAR VENT 20. REAR VENT ARM 21 ARM OPERATION (pass/fail) All values include the line resistance subtracted from the reading. *Test if Service Box is 400 square inches or greater IAW DA Pam 385-64. Pass/Fail Resistance: ohms Line Resistance: ohms Comments: Pass/Fail: References: PCD, December 2013; DA Pam 385-64. NOTE: LPS must be electrically tested for the electrical continuity of bonds every 24 months. LPS grounding rods subsystem must be tested every 24 months. CSU = Container Storage Unit EE = Environmental Enclosure ESM = Explosive Storage Magazine Pueblo Chemical Depot Appendix 2-3-14