Power. When and where you need it.

Similar documents
How To Power A Power Supply On A Powerline From A Power Source To A Power Box

POWER DISTRIBUTION. Power and Undercarpet Products POWER AND UNDERCARPET PRODUCTS. Chapter Summary

Tate s Wire & Cable Solution

TecCrete. Data Center Flooring

CommScope Intelligent Building Infrastructure Solutions (IBIS)

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Scope: Communications and Electronic Systems addressed in this section include:

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Movable Wall 8-Wire Base Electrical System - Product Notes

1 & 2 CIRCUIT. Architectural grade ISO 9001 quality JIT availability Open architecture ready for your fixtures now!

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Qualitative Analysis of Power Distribution Configurations for Data Centers

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Comparing Data Center Power Distribution Architectures

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

Excel Pre-terminated Copper and Fibre Optic Systems

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

Essential Power System Requirements for Next Generation Data Centers

Faraday Intelligent Fire Detection Systems

electrics P OW E R E N T RY B A S I C S P OW E R & C O M M U N I C AT I O N S B A S I C S P OW E R D I S T R I B U T I O N B A S I C S

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER

Electrical/ Communications. Panel Based Systems

Zone Distribution in the Data Center

InstaPATCH ZERO Solution Guide

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Faster Method for Connecting Customers in the Colocation Data Center

Open Office Cabling Architecture SYSTIMAX. Structured Cabling System Opens Office Cabling to New Possibilities

Understanding Electrical Terms

Advancements in Modularization

STABILOY BRAND FeeDeR SOLuTIONS

STABILOY BRAND FeeDeR SOLuTIONS

Wireless Networks and Power Quality

Cable Assemblies. Features and Benefits

Network Design. Yiannos Mylonas

Panduit Unified Operations Center

CYRUSONE COMPANY OVERVIEW BUILT FOR TOMORROW. READY TODAY.

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Data Center Cabling Design Trends

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

InstaPATCH Cu Cabling Solutions for Data Centers

IBM Enterprise Linux Server

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Cable Installation Project

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ADC Structured Cabling Solutions

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

TCTC Cabling Specifications

Errata NFPA 70. Proposed 2014 Edition

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

Office of Integrated Security Systems Longwood University Camera System Standards

APC APPLICATION NOTE #112

VIDEO CONFERENCING ROOM DESCRIPTION AND REQUIREMENTS INDIANA UNIVERSITY, BLOOMINGTON Indiana University DEFINITION

GRAFIK 5000TM/6000 /7000TM System Onsite Startup

PowerPlus. Integrated Power Distribution Cabinets. Most effective space-saving. integrated system on the market. Engineered to be shipped as a

Government. Network and Communications Infrastructure for Federal Government

Public Overview of the EMerge Alliance Data/Telecom Center Standard Version 1.0

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

AirBlock Data Center Doors

DEPARTMENTAL REGULATION

Gigabit to the edge. HP ProCurve Networking Solutions

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

INTELLIGENT WORKSPACE & STORAGE SOLUTIONS MEDIA STORAGE

Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper

The Shorten AutoCAD the road solution for mechanical, electrical, to done. and plumbing engineering. AutoCAD AutoCAD.

AirBlock Data Center Doors

Request for Proposal (RFP) IP Cameras/Door Access Control

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

DATA CENTRES POWERED BY EXCEL

SEAGATE SOFTWARE. About Seagate Software. IBDN Success Stories Technology. Currently, Seagate Software has customers in more than 75 countries

Data Center Solutions - The Containerized Evolution

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Smart Data Center Solutions

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

No Phone Line II-48 System

Ralls County Emergency Services Request for Proposal & Qualifications Emergency Communications Dispatch Consoles

21 st Century Campus Network Responsibility Matrix 5/26/10

Electrical Wiring Technical Bulletin

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

THE RTOS AS THE ENGINE POWERING THE INTERNET OF THINGS

Transcription:

Power Base

Power. When and where you need it. Power Base is the only modular electrical system that delivers seamless plug-and-play power from the closet to the desktop. It s also the only system backed by a solid history of innovation and reliability. After all, it was Haworth that pioneered the first modular power solutions for use in systems furniture more than 30 years ago. Today, this industry-leading product line has evolved into an integrated power delivery platform that provides both three- and four-circuit solutions for every workspace application, including freestanding and systems furniture, moveable walls, access floors, and ceilings. 1 2

Power Base AI Part of the Power Base family of solutions, Power Base AI is designed specifically for architectural applications. Unlike other electrical systems rated for underfloor or ceiling use, Power Base AI uses just four components, making even large and complex applications easier to plan, install, and maintain. And every component is reusable, so there s virtually no waste, and the system can be changed or expanded at any time. 1 Zone Distribution 2 Jumpers connect 3 Splitters are small 4 Service Modules Boxes provide the transition from a building s electrical system to Power Base AI s modular power distribution system. Available in three configurations with one 8-wire port, two 8-wire ports, or three 8-wire ports to easily accommodate a range of power densities. Zone Distribution Boxes, Service Modules, Splitters, and Infeeds for Haworth furniture and walls. Available in lengths from 5 to 50 feet, Jumpers provide plug-and-play connection between all of the system components. connector blocks that connect up to four Jumpers and allow the branching of power anywhere in the system. Splitters also enable lean and agile layouts that keep first costs low while maintaining flexibility. provide in-floor power and voice/data access and are available in quad and dual receptacle configurations. All Power Base AI Service Modules offer Haworth s patented snap-in receptacles, which allow quick change of circuit assignments and minimize the number of components in inventory. Power Base Voice & Data Power Base Voice & Data solutions include zone box housings and service outlets compatible with all brands of premise cabling products, allowing Haworth to integrate with any existing IT standard. 5 Power Base Voice & Data Zone Distribution Box Haworth can also provide a Haworth cabling solution using the Power Base Voice & Data Pre-Terminated Zone system, which offers a range of multi-port zone boxes and pre-terminated, pre-tested cabling, as well as data closet components. It s a zone-based, plug-and-play cabling system that installs fast and reconfigures even faster. Here are a few more Pre-Terminated Zone advantages: Arrives factory pre-tested and pre-terminated, limiting on-site labor and accelerating installation. Offers 100% reusability and virtually no waste. Exceeds TIA/EIA and ISO standards. Manufactured for Haworth by ADC, a world leader in structured cabling solutions. 3 4

Power Base The original Power Base system is used in Haworth s furniture and moveable walls. Power Base is an unsurpassed solution when you need quick circuit access, flexibility, durability, ease of management, and dedicated circuitry. Unlike other off-the-shelf systems, Power Base is designed and manufactured by Haworth, for Haworth. That s why, as part of Haworth s overall commitment to sustainability, Power Base is PVC free. 1 Power Distribution 2 Flexible Connectors 3 Receptacles with 4 Infeeds can deliver Assemblies (PDAs) are the heart of Power Base. Built into Haworth walls, panels, and tables, or quickly retrofitted in the field, these proven electrical components have a 25-year track record. And, all Haworth PDAs are nonhanded for unrestricted component placement. tie PDAs together. They are included with all powered panels. These plug-and-play connectors are keyed and color coded to distinguish the various circuit options and prevent wiring errors. programmable circuit assignments are a Haworth innovation. They are designed for maximum flexibility, and they minimize the investment in spare parts inventory. power via a floor box, underfloor or ceiling system, or power tap in a wall or column. Haworth s systems can be connected to building power through traditional fixed wire and conduit, but are most adaptable when connected through flooror ceiling-based Power Base AI. 5 6

Choosing a 3- or 4-Circuit Design Haworth s Power Base is available in both 3- or 4-circuit configurations, making it easier to adapt to specific user needs and building electrical systems. To assure safety, Power Base connectors are color coded, labeled, and keyed to prevent connection between incompatible circuit configurations. It s important to understand the advantages and disadvantages of each circuit configuration before choosing either 3-circuit or 4-circuit. The guide on the facing page is meant to help you make an informed decision based on your application. Hot 1 Neutral 1 Hot 2 Neutral 2 Hot 3 Neutral 3 Ground Isolated Ground Hot 1 Hot 2 Neutral 1 Ground Isolated Ground Hot 3 Hot 4 Neutral 2 Hot 1 Hot 2 Hot 3 Neutral 1 Ground Isolated Ground Hot 4 Neutral 2 3-Circuit/Separate Neutrals This option provides 3 circuits, each with its own neutral. Here s what to consider: Aligns with the 3 phase national power grid and most North American buildings. Is compatible with the following building power configurations: 3 phase (208Y/120V) Three wire single phase (120/240V) Single phase (120V) Offers the most adaptability to special power needs such as: multiple power sources facility energy control isolation of high harmonic loading Features receptacles with patented on-site circuit access programmability (available only on Power Base for furniture). Offers receptacles in common ground or isolated ground configurations. 4-Circuit/2+2 This option provides 4 circuits, two circuits share neutral #1, two circuits share neutral #2. Here s what to consider: Provides more circuits (4 vs. 3) for each homerun from the electrical closet, which can reduce the installed cost per circuit. Is compatible with the following building power configurations: 3 phase (208Y/120V) Three wire single phase (120/240V) Is sometimes less adaptable to special power needs such as multiple power source or facility energy control. Special power needs are typically planned in sets of two circuits In some cases, 10 gauge shared neutral may not fully isolate circuits Modular receptacles have fixed circuit access. Offers receptacles in common ground or isolated ground configurations. 4-Circuit/3+1 This option provides 4 circuits, three circuits share neutral #1, circuit #4 has a separate neutral. Here s what to consider: Provides more circuits (4 vs. 3) for each homerun from the electrical closet, which can reduce the installed cost per circuit. Is compatible with the following building power configurations: 3 phase (208Y/120V) Is sometimes less adaptable to special power needs such as multiple power source or facility energy control. Special power needs are typically planned only using circuit #4 In some cases, 10 gauge shared neutral may not fully isolate circuits Modular receptacles have fixed circuit access. Offers receptacles in common ground or isolated ground configurations. 7 8

Haworth and Power Base Make It Easy Haworth and Haworth dealers provide layout and planning services for Power Base products. As part of the planning process, we work with you to determine the combination of Power Base components that deliver the most function per dollar. And if the solution includes Power Base AI, we provide a future-proof, zone-based layout flexible enough to adapt to any space plan. We also make sure the electrical plan is aligned with the voice/data plan to avoid any interference issues. In addition, the detailed layout drawing helps to minimize construction schedules and reduce costs by ensuring that installation contractors know exactly what to do when they arrive on site. When the project is finished, the Haworth plan becomes an as built drawing for your facilities team that shows how all components are laid out and interconnected. Extract from a Typical Haworth Drawing Haworth Power Base Advantages More sustainable The Power Base system s inherent reconfigurability maximizes lifecycle and minimizes waste. Universal application All Power Base products are available in 3-circuit/separate neutral (3-3-2) or 4-circuit/ shared neutral (2+2, 3+1) configurations. Oversized shared neutral On all Power Base 4-circuit systems, a 10 gauge shared neutral provides protection from high currents due to non-linear loads. Foolproof connection All Power Base connectors are color coded and polarity keyed to prevent connection of electrically incompatible components. Flexible circuit assignment Power Base for furniture offers Haworth s exclusive programmable receptacles on 3-circuit systems and patented snap-in receptacles on 4-circuit systems for quick, easy change of circuit assignments. Power Base AI floor-mounted Service Modules also offer snap-in receptacles, offering an advantage over competitive systems in which circuit assignments can only be changed by replacing the entire floor module. Easier to expand and reconfigure Unlike competitive systems, every Power Base cable and connector contains all eight wires, allowing for easy reconfiguration or expansion at any point in the system. Ready to install Power Base components arrive prewired and pre-tested. No field wiring required, except for connection to building wiring. Furniture/architectural integration Power Base for furniture seamlessly connects with Power Base AI in the floor or ceiling. Large capacity in a streamlined package The Power Base AI 3-port Zone Distribution Box is only 11 x 11 x 2 1 /8, but can deliver 4800 VA in a 4-circuit configuration or 3600 VA in a 3-circuit configuration. Floor Modules built for heavy traffic Power Base AI low profile and standard height Service Modules are equipped with steel covers that can withstand a 1000 lb point load and significantly exceed UL strength requirements. Built-in daisy chain capability Power Base AI Service Modules include multiple modular connectors, allowing power to pass through and be routed to subsequent Service Modules. Underfloor air compatible Power Base AI components are UL 183 listed for use in air handling spaces other than plenums per NEC Article 604. Such spaces include air handling spaces under access floors and above dropped ceilings. Connects to non-haworth systems While Power Base AI offers the most value when used with Haworth furniture and wall systems, Haworth offers Jumpers that allow field-wired transitions to non-haworth systems. 9 10

For more information call 800.344.2600 or 616.393.3000. Download additional copies at haworth.com. This brochure is printed on FSC certified U2 :XG, manufactured with electricity in the form of renewable energy (wind, hydro, biogas) and contains a minimum of 30% post-consumer recovered fiber. FSC is the global benchmark for responsible forest management. 30% Haworth is a registered trademark of Haworth, Inc. Printed in USA Haworth, Inc. 2009 03.09 Item #0291 haworth.com haworth-europe.com haworth-asia.com