CANNON T4 MODULAR DATA CENTRE HALLS

Similar documents
Enterprise Data Centres

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

The Pros and Cons of Modular Systems

Case Study Nottingham Trent University

Data Centre Solutions energy efficient by design

Containment Solutions

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Data Center Solutions - The Containerized Evolution

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Scalable. Affordable. Flexible. Fast.

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Colocation Selection Guide. Workspace Technology Ltd

Portable Energy Efficient Data Centre Solution

EXAMPLE OF A DATA CENTRE BUILD

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

How to Build a Data Centre Cooling Budget. Ian Cathcart

IBM Portable Modular Data Center Overview for Critical Facilities Round Table

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

AIRAH Presentation April 30 th 2014

IPSIP M series-m Modular Data Center

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

SMART SHELTER CONTAINER

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Managing Data Centre Heat Issues

Blade Server & Data Room Cooling Specialists

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

GREEN DATA CENTER DESIGN

University of St Andrews. Energy Efficient Data Centre Cooling

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

POD S in Data Centres. The Frame Group Pty Ltd

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

Direct Fresh Air Free Cooling of Data Centres

Analysis of data centre cooling energy efficiency

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

A Blueprint for a Smarter Data Center Data Center Services helps you respond to change

High-density modular data center making cloud easier. Frank Zheng Huawei

APC APPLICATION NOTE #112

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Cabcon. Data Centre Solutions. an acal group company UK +44 (0) IRE (00353)

How To Build A T7 Rack For Information Technology

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Types of Prefabricated Modular Data Centers

Defining Quality. Building Comfort. Precision. Air Conditioning

Data Center Cabling Design Trends

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Capgemini UK Infrastructure Outsourcing

Introducing UNSW s R1 Data Centre

Data Center Components Overview

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

Title: Design of a Shared Tier III+ Data Center: A Case Study with Design Alternatives and Selection Criteria

APC by Schneider Electric

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

T:

National Grid Your Partner in Energy Solutions

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Digital Chicago. 600 south FeDeraL - chicago grand ave - FranKLin ParK 350 east cermak - chicago

In Row Cooling Options for High Density IT Applications

NetApp Data Center Design

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

RiMatrix S Make easy.

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Innovent LASER Packaged Fresh Air Conditioning Units

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Standardised Data centres. Sales presentation

Raised Floor Data Centers Prepared for the Future

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

BELLE VUE MANCHESTER DATA CENTRE

Thermal Storage System Provides Emergency Data Center Cooling

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Electrical. This section applies to the design and installation of building power distribution systems.

Benefits of. Air Flow Management. Data Center

Re Engineering to a "Green" Data Center, with Measurable ROI

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Technical Systems. Helen Bedford

Data Centre Testing and Commissioning

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

How To Power And Cool A Data Center

Datacentre South London Data sheet

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

La modularidad a nivel de Data Centers integrales. Arturo Maqueo Business Development Manager Mexico y Centro America

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

Data Center Energy Profiler Questions Checklist

Simplifying Data Center Design/Build

Cody Park One of Ark s high integrity data centre campus sites

Transcription:

CANNON T4 MODULAR DATA CENTRE HALLS Halve up-front investment, use a Modular fit out approach Highly efficient, Low PUE, Scalable system with reduced Capex and Opex Turnkey solutions available complete, commissioned and online.

Modular Data Centre Halls: Dramatically reduce upfront investment when fitting out shell buildings as new, resilient high performance Data Centres. A unique solution developed by Cannon T4 Data Centre Solutions enables true pay as you grow phased fit out. By using an indoor variant of the Cannon Pre-Engineered system, a Granular Modular Data Centre may be quickly built within a new or suitable pre-existing building. Quick, Flexible system: The Cannon system provides pre-fabricated Modular Data Centre halls, which can be of any size and various heights, they are rapidly erected and equipped as a customer s business grows. Commissioned ready for fit out of IT Equipment by clients or integrators within eight to twelve weeks. The White Space, Aisles, Racks, Power, Cooling, Fire protection, DCiM, Security, CCTV, Cable containment and other needs are included for IT integration readiness. This cutting edge solution has won multiple international awards worldwide. It provides high levels of physical security as well as leading levels of efficiency and operational resilience. Rating level 1, 2, 3 or 4 (TIA 942) available as required.

Modular Data Centre Halls: Construction All components are pre made, High Quality, precision, man portable parts. This simplifies the whole process of fitting out within the shell building, as access through small or difficult access points poses no problem. The components are flat packed. Transport to sites with difficult access is easy even at altitude. No cranes or heavy construction equipment whatsoever is required for the build. The Cannon MDC Halls weigh only 280kg per square meter, (58lb per square foot). Cabinets can be loaded to 1000kg (2200lb). Overall average floor loading of a populated MDC hall is <1 ton per square meter (48 x 1 ton loaded cabinets plus MDC frame = 69 metric tons in 75 sq meters). Non-Intrusive Deployment: Only hand, battery operated tools are used during the assembly process, there are no wet trades, cutting or dust, there is no disturbance to occupiers of other facilities within the building, or in the vicinity. Rapid availability: Most of the mechanical and electrical infrastructure is also based on premade modular systems and hence a complete, commissioned & tested data centre can be available in a few months rather than years. IT Ready: Racks / Cabinets, Power Distribution, UPS, Battery systems, Fire Protection, Cooling units all are quickly installed Inside the white space of a Cannon MDC Hall when the white space is fitted out. The Cannon cable and fibre raceway system is built in allowing for simple installation of pre-terminated copper and fibre cabling.

Modular Data Centre Halls: Flexible Layout; The unique Cannon solution can encompass any floor layout. The Halls can be deployed in any size to suit the specific requirements of the occupying client be it single or double cabinet rows, cold and hot aisles or open freeform spaces Any size or shape: Typically a thirty to fifty Rack hall is popular but uniquely Cannons MDC solution may encompass thousands of cabinets if desired. The Cannon MDC halls can also be expanded in any direction on day 2 / 3. Flexible geometry: The halls can even be built around existing beams and structures including column supports, pipework, risers, lift shafts and services. Building columns may be hidden within the MDC with suitable fire rating protection incorporated. Diverse Equipment: May be configured to suit any size rack cabinets including 3 rd party cabinets and equipment, (Tape Stores, SAN, Large Switches, Server systems etc).

Power systems: Power systems can be incorporated into the white space or deployed into separate rooms and spaces with controlled access. Diverse Power A and B provision:- 200kva Modular UPS and Battery cabinets combined with 250kva switchboards fitted at the end of each row of rack cabinets. Whips are then run from the switchboard cabinet to IEC sockets under the floor. By using A and B circuit s dual power is provided to the racks to meet TIA 942 rating 3. Bypass and maintenance: The UPS bypass and isolation switchgear may be within the switchboard cabinet. Power metering for both three phase and single phase circuits may be incorporated in the switchgear as well as finger safe isolation of circuits to make them safe for live working. Cabinet / Rack Power Distribution: Two 32A Single phase PDU strips are generally fitted in every rack space, 20 x C13 and C19 off two 16a branch circuits being most common. Two PDU s one fed off the RED A UPS and one fed off the BLUE B Ups provides diverse power to the rackspace. DCiM: Cannon Data Centre Manager monitors and reports on the critical systems and efficiency of the system 24/7. Reporting that meets the requirements of Ashrae, Green Grid and the EU Data centre code of conduct may be implemented. The data collected can be ported to 3 rd party monitoring services if required. Lighting: LED Lighting with optional occupancy sensors provides efficient overall lighting of the space to TIA guidelines. Emergency lighting luminaries are also provided over the entry and exits.

Cooling systems: Cannon s industry leading, ultra-compact and highly efficient Within Row Cooling solution complements the MDC Hall system perfectly. Easily scaled to suit the cooling required both on day one and suitable for quick future expansion. Automatic speed control varies the amount of cold air the units expel as they deal with the hot air on the rear of the units while keeping the cold aisle stable. With 30kw of cooling in only 200mm of width they deliver up to 3000 cfm of close coupled cooling air. Quiet, High Volume: Six large, hot swappable radial blowers are quiet and efficient, only consuming 600w at 100% and <100w at 25% load. 30kw max provides 25kw of sensible cooling when used with chilled water at 12 C. Efficient Water based Free cooling mode: Coupled with modern, high efficiency Chilled water plant, compatible ambient conditions and free cooling coils a cooling PUE of under 1.06 is possible. (#1) DX: If a Direct Exchange DX Gas system is desired rather than water then multiple 25kw units can provide 18kw of sensible cooling coupled to suitable external heat exchangers (#2) (No Free Cooling). Air Side Economisers / Flood cooling / Fresh air: Optionally the Cannon MDC hall may be built to encompass large scale air handling systems with diverse free cooling. Air may be delivered both under and over floor into the cold aisles. The hot exhaust air being removed by overhead ductwork, chimneys and low energy fans. These systems can deliver outstanding efficiencies at large sizes. (#1) 8 x WIRC units @ 500w = 4kw, 3kw of water pumps and 5kw of free cooler fan energy = 212kw total for 200kw of sensible cooling (free cooling metric based on Southampton UK Winter period). (#2) External DX heat exchanger must be within 70m of the WIRC DX air handler and <15M above or below.

Incremental Fit out: The Cannon MDC halls system is easily built in stages as your IT requirement grows. The halls can even be part built without the cabinet internal infrastructure, power and cooling systems. When the business demand increases the required capacity, Power and cooling modules are quickly installed, cabinets fitted out and the white space bought on line in just a short time. Shared occupancy friendly: Adjoining halls are assembled without impeding the use of other occupied halls. By using suitable incremental sizes of power and cooling modules the total Capex may be evenly spread over many years. High Density Options: If extreme power density within the building envelope is required the Cannon MDC system can be built on multiple floors using a suitable mezzanine floor system. The halls can also be assembled on suitable load bearing floors of traditional buildings if required. Rooms and spaces: As well as the Data Hall white space the system can provide special purpose rooms for Power, Cooling, Fire, Network Control Centres, Secure entry vestibules and People traps, Offices, Cloakrooms etc. Disassembly: Returning a rented building to its original status is easy, quick and inexpensive as the Cannon MDC is quickly disassembled when necessary. Redeployed the system may be reused in a new format if desired, and if not it is nearly 100% recyclable.

Hybrid Layout: Where a combination of a shell building, MDC, Container and other format buildings are required to best utilise a site the solutions may be easily mixed and matched as required. Front of shop portals may be built with modular buildings behind. A hallway built using interconnecting corridors of MDC modules provides a seamless interior space. Infrastructure: The operational infrastructure within the MDC is state of the art, and is identical to the systems underpinning some of the world s most advanced data centre operations. Features and Options: All the features of a traditional data centre can be incorporated into an MDC Halls solution from Cannon:- Large switch and SAN racks. 3 rd Party cabinets and freeform space. Within row, over floor or underfloor cooling. UPS and Integrated switchgear. Separate power, Cooling, M&E plant rooms. Fire protection using gas (FM / Novec) or water based systems. Secure mantraps. Diverse cabling with Multi level & colour cable & fibre raceways. Wide aisles both Hot and Cold. Space saving sliding doors. Environmental and power monitoring. DCiM, Dashboards. Remote monitoring. CCTV. Access control. Security. Free cooling water chillers. Standby and Prime generators. Rotary UPS. Rating to resilience levels 1,2,3 or 4 (TIA 942-A).

The Cannon T4 Modular Data Centre is the result of almost forty years of continuous experience. The solution has steadily evolved and developed, keeping abreast of emerging technologies to arrive today at the pinnacle of the Data Centre world. This solution, available from Cannon and our worldwide partner network, enables clients to avoid high up front expenditure by pacing their investment in line with the occupied space being used within their Data Centres. This removes the over investment caused by the underutilised and expensively equipped traditional Data Centre space. As every Data Centre requirement is different, The Cannon T4 Data Centre Solutions team would be pleased to offer any assistance in specifying, designing and quoting a solution tailored to your needs, from a single cabinet to a multi megawatt DC our team of Engineers, Support staff and local integration partners are available to aid customers worldwide. See cannontech.co.uk for contact details of a partner close to you. A selection of Cannon Technologies Multi-International Awards