EC-fans. Energy efficient and environmentally friendly



Similar documents
TFSR & TFSK Roof Fans

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

RPV - RP - RA air handling units

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Energy Saving ECM Motors and Fans Ventilation Catalogue

The ventilation of the future.

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Transformer oil cooler ALFA A02

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

CADB and CADT-D / DI / DC Series

Air Comfort. Technical Catalogue > Roof Fan STOF

Ventilation Solutions Kitchens. fantech

squrboxbox heat recovery squrboxbox I technical information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

UDSA - UDSBD unit heater

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Electric Rotary Actuator - On/Off or programmable control actuator

ECOCIAT. Domestic hot water heat recovery unit

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

FULL DC INVERTER SYSTEMS

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Surface Technology. Centrifugal Fan GMD

EC medium pressure axial fans. The effi cient system solution.

Topvex SX/C, Topvex TX/C. Air Handling Unit

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

Data Center Cooling. The engineer s choice

Decree of the Ministry of the Environment on fire safety of ventilation systems

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

HERZ-Thermal Actuators

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Combi Unit Genius. The energy efficient Building Service Centre

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Digital inductive conductivity transmitter

ICQ Series - square centrifugal

How To Drive A Compact Serie 1

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

PLUG and PLAY VRV Connection

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard


HVAC air curtains. Type InduAir

Installation and maintenance instructions. Danfoss Vent

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

RRV934. Multi-controller. Synco living

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Analogue addressable devices

ebm-papst North America

KONRAD. Hybrid Fancoil Series

Innovent LASER Packaged Fresh Air Conditioning Units

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

IH E Sigma Island 90

TELESCOPE Motorized Lighting Suspension

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Incubator with mechanical convection

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Material test chamber with mechanical convection

Operation and Installation Manual. Max Series

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SECTION HEAT PUMPS

Heating, air-conditioning, cooling

New XUY roller sensors

Generators TEM. for small hydroelectric power stations. Electric Machines

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

SUNON SPECIFICATION FOR APPROVAL

ACTIV-8 PLUS Insulated Conductor Bar

USER S MANUAL HSC-24A

Photovoltaic Solar Energy Unit EESFB

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

Focus on Building Louvres. Sun shading & comfort ventilation.

DuroSite TM High Bay Lighting

TOP 10 NOISE CONTROL TECHNIQUES

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

How To Use A Ds340 (Dsp)

Under sill units. Type FSL-B-ZAS

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

Spetec Laminar Flow Systems. Operating Instructions

Transcription:

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans EC-fans Energy efficient and environmentally friendly

2 I EC-fans Energy efficient & environmentally friendly fans The products in this leaflet are equipped with EC-motors. ECtechnology is intelligent technology, using integral electronic control to ensure that the motor always runs at optimal load. What can EC achieve? EC-fans are favoured for their economical use of energy and simplification of control. EC-fans are driven by energy-saving motors with electronic control (commutation unit) ensuring optimal operating efficiency. According to their design principle, these are synchronous motors, which run without slip and therefore no slippage losses occur. An excellent solution for demand responsive ventilation systems. Another pro-environmental aspect relevant to air supply and air conditioning equipment in particular is noise level. Here too, the advantage is with EC-motors, which run silently in controlled operating conditions. EC-motors have longer service life due to lower winding tempe ratures resulting in lower wear and tare. EC-motors with integrated electronic control can easily be varied in speed to match airflow demand. For the same air volume, they consume distinctly less energy than AC motors. EC-motors have high energy-saving potential not only at full load, but especially at part-load, where the loss of efficiency is very much lower than with an asynchronous motor of equivalent output. Advantages with EC motors: Up to 9 % higher efficiency than conventional systems Long service life due to small heat losses in the motor Easy to control with -1V DC or PWM signal Low sound level throughout the entire fan performance All control and protection electronics are integrated in the motor, easy connection Ventilation on demand easy to adjust ventilation rate to actual need. The following is included when selecting an EC motor: Overheat protection Overload protection Protection against locked rotor Control electronics Softstart, starts slowly and gradually increases to full speed over a predefin ed time. EC-Vent control Energy efficient ventilation is about designing a system in a smart way, using a fan that has a high efficiency and adjusting the ventilation rate to the actual need, instead of always operating at full capacity, while maintaining good indoor air quality. Today Systemair probably has the widest range of EC fans on the ventilation market, and are happy to introduce a control system that will make it easy for the contractor, installer and end user to achieve Demand Control Ventilation (DCV). The system contains a central control and a room controller that are connected with SELV. (Safety Extra Low Voltage). Built in transformer EC-Vent room unit 24V supply to dampers Built in humidity and temperature sensor in the room controller Ability to connect CO 2 sensor, presence sensor, humidity sensor etc. Possibility to create a week schedule. By using energy efficient EC-fans with intelligent control, your system will meet the ventilation requirements of both new building and refurbishment projects.

EC-fans I 3 Comparison with conventional technology K EC/AC 2 MUB EC/AC 45E4 KVKE EC/AC 315 DVC 355-S/DVS 355E4 AC KBT EC/AC 2E4 TFSR EC/AC 16 Power consumption per year is based on an installation running continuously. The CO 2 impact based on as an average of the CO 2 emission to produce continuously electricity for the European countries. Source: Umwelt- Bundes-Amt Germany. Factor.6 kg CO 2 /kwh

4 I EC-fans K EC, circular duct fans High efficiency in all areas of the fan curve 1 % speed controllable by -1V or PMW signal Easy adjustment of ventilation rate by installed potentiometer Electronic motor protection Supplied with mounting bracket. Potentiometer -1V located in the electrical terminal box øb øa (F) C D E The K-EC series is designed for installation in ducts. All the K-fans have minimum 25 mm long spigot connections. The fans have backward-curved blades and external rotor motors (EC). The FK mounting clamp facilitates easy installation and removal, and prevents the transfer of vibration to the duct. The fans are delivered with a pre-wired potentiometer (-1V), set at 1V (factory default). This can easily be adjusted should the installation require at a lower duty. To protect the motor from overheating the fan has integral thermal contacts with electrical reset. Motor protection is integrated in the electronics of the motor. The casing is manufactured from galvanised sheet steel with the seams folded to give the fan a close to air tight casing. Outdoor mounting and wet room applications are possible due to the fans air tight casing and IP 55 rated terminal box with IP 68 rated M2 cable gland. 4 88 Accessories FK CB RSK LDC øa K EC A B C D E (F) 16 159 286 25 147 26 198 2 199 336 3 148 27 25 25 249 336 3.5 144.5 27 22 315 M 314 48 32.5 16.5 27 22 315 L 314 48 37.5 16.5 27 225 All dimension in mm. FFR VBC CWK MTP EC-Vent K EC 16 2 25 315 M 315 L Voltage/Frequency V/5 Hz 23 1~ 23 1~ 23 1~ 23 1~ 23 1~ Power W 74,4 78,6 119 166 34 Current A,63,63,92 1,14 2,8 Max air flow m 3 /h 544 774 133 1415 1732 R.p.m. 315 2468 2628 2113 2719 *) Sound pressure level, 3 m db(a) 47 51 46 5 57 Weight kg 3 3,8 3,5 7 7 Insulations class, motor B B B B B Enclosure class, motor IP 44 44 44 44 44 *) Sound pressure level at 2 m 2 Sabine, equivalent to 1 m free field.

EC-fans I 5

6 I EC-fans KD EC, circular duct fans High efficiency in all areas of the fan curve 1% speed controllable Integrated electronic motor protection Supplied with mounting bracket Easy adjustment of ventilation rate by installed potentiometer The KD-EC series have external rotor motors (EC) with mixed flow impellers which reduce the external dimensions of the fans. The casing is manufactured from galvanised steel. These fans produce high capacity in relation to their compact design. Brackets are supplied with the fans to simplify installation. The FK mounting clamp facilitates easy installation and removal, and prevents the transfer of vibration to the duct. The fans are delivered with a pre-wired potentiometer(-1v) set to 1V (factory default). This can easily be adjusted should the installation requires a lower duty. Motor protection is integrated in the electronics of the motor. KD EC 315E KD EC 355E/4D/4E/45D/5D Accessories ø315 49 øa B ø1(4x) FK RSK 484 ød C 33,5 2 ø32 ø315 ø355 ø455 54 25 2 69 E F øh øi øj K G CB FFR LDC CWK 11 11 L L VBC MTP 65 65 EC-Vent KD EC øa B C ød E F G øh øi øj K L 355E 355 4 516 1(4x) 38 59 38 355 4 53 59 11 4D/4E 4 44 62 12(4x) 33 61 37 4 45 56 662 18,5 45D 45 46 686 12(4x) 45 76 5 45 5 66 812 18,5 5D 5 46 643 12(4x) 45 76 5 45 5 66 812 18,5 All dimension in mm. KD EC 315E 355E 4D 4E 45D 5D Voltage/Frequency V/5 Hz 23 1~ 23 1~ 4 3~ 23 1~ 4 3~ 4 3~ Power W 428 355 1937 926 1872 1848 Current A 1.98 1.69 2.99 4.8 2.91 2.83 Max air flow m 3 /s.963 1.5 2.35 1.93 2.57 2.77 R.p.m. 1723 1295 196 1452 167 165 Soundpressure level at 3 m db(a) 71.8 53.4 73.9 62 69.3 68.1 Weight kg 14,2 18.6 24 26.5 32.5 32 Insulations class, motor F F F F F F Enclosure class, motor IP 54 54 54 54 54 54

EC-fans I 7 KD-EC 315E KD-EC 355E KD-EC 4E 92 83 91 58 58 73 73 82 1V 2,8V KD-EC 45D KD-EC 5D 1V 1V 5,3V 3,5V

8 I EC-fans KVKE EC, circular duct fans High efficiency in all areas of the fan curve 1% speed controllable Integrated electronic motor protection Easy adjustment of ventilation rate by installed potentiometer Low noise level Potentiometer -1V located in the lid The KVKE EC models have impellers with backward-curved blades and maintenance-free external rotor motor (EC). These fans develop relatively high static pressure and produce very high efficiency. The fans are delivered with a pre-wired potentiometer (-1V). The potentiometer is pre-set to 1V (factory default). This can be adjusted should the installation require a lower duty. The KVKE motor and impeller are mounted on the access cover for easy maintenance. The service cover can be easily removed by withdrawing the hinge pin. Motor protection is integrated in the electronics of the motor. The fans can be installed in any position and are easy to connect to spiral ducts using FK mounting clamps. The KVKE casings are manufactured from galvanised sheet steel and are thermally and acoustically insulated with a 5 mm layer of rockwool with a surface liner which prevents the migration of fibres into the airstream. The plug and socket contact between lid and casing ensures that when opening the fan casing the fan is separated from the mains supply. No need for on/off switches for maintenance. Accessories G H 5 C B *) FK RSK E CB LDC D F 47 * ) Handle on KVKE 315 EC 27 A FFR CWK KVKE EC A B C D E F G H 125 125 433 479 125 128.5 442 246 47 16 16 482 528 145.5 132.5 55 266 53 2 2 482 534 15.5 149 55 33 53 25 25 578 7 176 174 596 359 62 315 315 68 82 28.5 27.5 75.5 43 73 VBC MTP EC-Vent KVKE EC 125 16 2 25 315 Voltage/Frequency V/5 Hz 23~ 23~ 23~ 23~ 23~ Power W 68.7 67.8 156 265 395 Current A,54,53 1,1 1,64 2,38 Max air flow m 3 /h 374 544 864 1156 1865 R.p.m. 3339 2592 333 2821 238 *)Sound pressure level, 3 m db(a) 41 39 46 49 5 Weight kg 13 17,5 19 28,1 38,8 Insulation class, motor B B B B B Enclosure class, motor IP 44 44 44 44 44 *) Sound pressure level at 2 m 2 Sabine (equivalent to 1 m free field)

EC-fans I 9

1 I EC-fans KVO EC, insulated circular duct fans High efficiency in all areas of the fan curve 1% speed controllable Integrated electronic motor protection Easy adjustment of ventilation rate by installed potentiometer Low noise level The KVO-EC motor and impeller are mounted on the access cover for ease of maintenance. The service cover can be easily removed by withdrawing the hinge pin. Motor protection is integrated in the electronics of the motor. The fans can be installed in any position and are easy to connect to spiral ducts using FK mounting clamps. The KVO-EC models are manufactured from galvanised sheet steel and the lid is insulated with 4mm rockwool. The fans are delivered with a pre-wired potentiometer (-1V) that allows you to easily select the desired working point. E G H D F A C B KVO A B C D E F G H 1 1 329 367 69 76 3 15 15 125 125 329 367 84 72 3 15 15 16 16 329 367 99 9 3 185 185 2 2 419 466 123 19 435 22 22 25 25 527.5 568 151 133 558 27 27 315 315 535.5 58 186 166 58 34 55 355 355 572 661 29 231 64 425 6 4 4 572 653 221 29 64 425 6 KVO EC 1 125 16 2 25 315 Voltage/Frequency V/5 Hz 23 1~ 23 1~ 23 1~ 23 1~ 23 1~ 4 3~ Power W 6 111 116 123 312 331 Current A.48.86.89.96 1.91 2.4 Max air flow m 3 /s.9.13.15.24.47.53 R.p.m. 2499 2724 2411 2577 2799 2264 Sound pressure level at 3 m db(a) 43.2 47.6 48.4 5.7 57.4 55.4 Weight kg 5.6 5.6 6 1.3 2.4 25.6 Insulation class, motor B B F B F F Enclosure class, motor IP 44 44 44 44 44 44

] EC-fans I 11 4 3 1 2 3 KVO-EC 1 11327/11328 5 4 2 4 69 KVO-EC 125 1134/11341 62 3 65 2 56 2 63 7 1 56 58 64 1 53 64 66 57 43 47.3.6.9 1 54 48 55.4.8.12.16 12 9 1V [W 6 3 4,5V.3.6.9.4.8.12.16 8 6 2 4 KVO-EC 16 11317/11318 8 6 3 6 9 KVO-EC 2 11323/11324 4 72 4 72 72 2 63 65 54 56 49 48.4.8.12.16 2 65 75 58 69 61 47 47.1.2.3 12 9 6 16 12 8 3 4 1 75 4 8 12 16 2 KVO-EC 25 11338/11339 1 75 5 1 15 2 KVO-EC 315 11349/11351 5 79 5 81 25 71 79 25 76 83 62 73 63 53 5.2.4.6 66 52 7 55.2.4.6 79 4 4 3 3 2 2 1 1

12 I EC-fans MUB EC, square duct fans High efficiency in all areas of the fan curve 1 % speed controllable Integrated electronic motor protection Low noise level Flexible air flow direction due to removable panels Installation in any mounting position Safe and maintenance free operation Mini MUB 2 MUB-EC fans are driven by EC-external rotor motors. All motors are suitable for 5/6Hz. The input voltage for single phase units can vary between 2 and 277V, for three phase units between 38 and 48V. Speed control by a -1V signal (MTP/MTV controller or EC-Vent). All models are equipped with impellers with backward curved blades, manufactured from aluminium. The casing consists of an aluminium frame with fibreglass reinforced plastic corners of PA6; and are shockresistant. The double skin panels are manufactured from galvanized steel with 2 mm mineral wool insulation. The panels are removable, any outlet side can be used, allowing flexible ventilation solutions. Installation in any mounting position is possible. The Mini-MUB model has an insulated casing (2 mm Armaflex), manufactured from galvanised steel, and PA6 25GV impellers. Coming soon: MUB-EC with integrated potentiometer for easy adjustment of the ventilation rate. F A MUB EC A B C ød øe F 25 315 5 5 42 315 2 4 25 355 5 5 42 355 224 4 42 4 67 67 59 4 253 4 42 45 67 67 59 454 286 7 øe ød C B 42 45 K 67 67 59 45 286 7 42 5 67 67 59 54 321 7 62 56 8 8 72 56 36 7 62 63 8 8 72 63 47 7 MUB EC 25 315 A2 25 355 A2 42 4 A2 42 45 A2-K 42 45 A2 42 5 A2 62 56 A2 62 63 A2 Voltage/Frequency V/5 Hz 23~ 23~ 23~ 4 3~ 23~ 4 3~ 4 3~ 4 3~ Power W 18 43 378 117 58 11 2 256 Current A 1,4 2,7 2,26 1,95 2,4 2,18 3,1 3,9 Max air flow m 3 /h 2466 3 3881 63 51 744 1789 135 R.p.m. 187 166 1339 156 125 134 136 121 *) Sound pressure level, 3 m db(a) 44 48 48 56 52 56 57 67 Weight kg 3 37 58 62 62 7 135 13 Insulation class, motor B B B B B B F F Enclosure class, motor IP 44 44 44 54 54 54 54 54 *) Sound pressure level at 2 m 2 Sabine (equivalent to 1 m free field)

EC-fans I 13 Straight through air direction 9 air direction

14 I EC-fans DVC/DVCI, roof fans High efficiency in all areas of the fan curve 1 % speed controllable Integrated electronic motor protection Low noise level Safe and maintenance free operation Coming soon: DVC-S with integrated potentiometer for easy adjustment of ventilation rate. C A B ød E H F ød G The DVC roof fans are driven by EC-external rotor motors, energy saving motors with high efficiency. The input voltage for single phase units can vary between 2 and 277V, for three phase units between 38 and 48V. All motors are compatible with 5 and 6Hz supply. Motor protection is integrated in the electronics of the motor, no additional external motor protection device is required. Casing from seawater-resistant aluminum. Backward curved impellers manufactured from polyamide PA 6 for size 19 and 315. From 355 up to 63 impellers manufactured from seawater resistant aluminium. DVC-S suitable for speed control with potentiometer. DVC-P with integrated pressure sensor, the electronics in the motor are programmed for a contstant pressure operation. M2x1,5 G øi(4x) DVC/DVCI A B C ød E 19-225 37/497 295 17/179 213 335 315 56/69 47 33 285 435 355-4 72/874 618 39/439 438 595 45-5 9/968 73/748 465/479 438 665 56-63 (DVC) 115/1315 955/135 56/6 65 939 F G H øi 245 15 6xM6 1(4x) 33 146 6xM6 1(4x) 45 2 6xM8 12(4x) 535 237 6xM8 12(4x) 75 293 8XM8 14(4x) DVC/DVCI 225-P/225-S 315-P/315-S 355-P/355-S 4-P/4-S 45-PK/45-SK Voltage/Frequency V/5/6 Hz 23 1~ 23 1~ 23 1~ 23 1~ 23 1~ Power (P1) W 166 173 378 381 614 Current A 1.17 1.18 2.31 2.3 2.79 Max air flow m 3 /s.261.546.918 1. 1.43 R.p.m. min-1 3278 1867 1657 1348 13 Max temp. of transported air C 6 6 6 6 6 when speed controlled C 6 6 6 6 6 Sound pressure level, 4 m/1 m, DVC db(a) 58/51 47/39 5/42 49/41 53/45 Sound pressure level, 4 m/1 m, DVCI db(a) 53/45 41/33 46/38 43/35 4/32 Weight, DVC/DVCI kg 8/13 11/16 25/3 29/34 45/38 Insulation class, motor B B B B B Enclosure class, motor IP 44 44 44 44 54 DVC/DVCI 45-P/45-S 5-P/5-S 56-P/56-S 63-P/63-S Voltage/Frequency V/5/6 Hz 4 3~ 4 3~ 4 3~ 4 3~ Power W 148 984 1873 2444 Current A 1.79 1.66 2.88 3.72 Max air flow m 3 /s 1.7 1.84 2.99 3.59 R.p.m. min-1 1558 1339 1359 129 Max temp. of transported air C 6 6 6 6 when speed controlled C 6 6 6 6 Sound pressure level, 4 m/1 m, DVC db(a) 51/48 55/47 63/55 64/56 Sound pressure level, 4 m/1 m, DVCI db(a) 5/42 51/43 55/47 57/49 Weight, DVC/DVCI kg 45/43 49/57 DVC 6/6 DVCI 7/7 DVC 8/8 DVCI 9/9 Insulation class, motor B B F F Enclosure class, motor IP 54 54 54 54

EC-fans I 15

K 16 I EC-fans DVC POC + FTG, roof fan Integrated pressure sensor, no power supply required Temperature sensor for outdoor temperature compensation 1 % speed controllable Integrated motor protection Safe and maintenance free operation Sizes 315 up to 5 include a tilting device for service options The DVC-POC roof fans are driven by EC- external rotor motors, energy saving motors with high efficiency. The input voltage for single phase units can vary between 2 and 277V, for three phase units between 38 and 48V. All motors are compatible with 5 and 6Hz supply and from size 355 up to 63 are suspended on effective vibration mountings. Motor protection is integrated in the electronics of the motor, no additional external motor protection device is needed. The DVC-POC versions have integrated pressure sensors and temperature sensor for outdoor temperature compensation. The electronics can be programmed for pressure constant operation or pressure constant operation combined with outdoor temperature compensation. The factory setting is pressure constant operation with outdoor temperature compensation. Casing from seawater-resistant aluminum. Backward curved impellers manufactured from polyamide PA 6 for size 315. From 355 up to 63 impellers manufactured from seawater resistant aluminium. A B F G_ M2x1,5 H G L D C I E DVC POC A B C D E F G H øi øk L 315 56 47 33 393 435 33 146 6xM6 1(4x) 285 443 355 72 618 39 454 595 45 2 6xM6 12(4x) 438 54 4 72 618 39 475 595 45 2 6xM8 12(4x) 438 525 45K/45/5 9 73 465 53 665 535 237 6xM8 12(4x) 438 58 56/63 115 955 56 6 939 75 293 8xM8 14(4x) 65 - DVC POC+FTG 315 355 4 45-K 45 5 DVC POC 56 63 Voltage/Frequency V/5/6 Hz 23 1~ 23 1~ 23 1~ 23 1~ 4 3~ 4 3~ 4 3~ 4 3~ Power W 173 378 381 58 148 984 1873 2444 Current A 1,18 2,31 2,3 2,79 1,79 1,66 2,88 3,72 Max air flow m 3 /s,546,918 1 1,83 1,7 1,84 2,99 3,59 R.p.m. 1867 1657 1348 125 1558 1339 1359 129 Max temp. of transported air C 6 6 6 6 6 6 6 6 when speed controlled C 6 6 6 6 6 6 6 6 Sound pressure level, 4 m db(a) 47 52 49 53 56 55 63 64 Sound pressure level, 1 m db(a) 39 42 41 45 48 47 55 56 Weight kg 25 25 29 45 45 49 58 85 Insulation class, motor B B B B B B B F Enclosure class, motor IP 44 44 44 54 44 54 54 54

EC-fans I 17 5 4 5 1 15 2 DVC 315-POC + FTG 5835/5836 6 2 4 DVC 355-POC + FTG 5828/5829 6 2 4 DVC 4-POC + FTG 5837/5838 3 75 4 73 8 4 76 2 1.2.4.6 2 15 1 5 56 65 57 71 65 72 76 2.4.8 1.2 4 3 2 1 5 44 6 69 62 74 79 82 2.4.8 1.2 4 3 2 1 44 44 61 65 7 76 79 6 5 4 2 4 DVC 45-K-POC + FTG 7231 8 6 25 5 DVC 45-POC + FTG 82 83 5966/5967 8 6 25 5 DVC 5-POC + FTG 86 5969/597 3 4 75 4 78 87 2 86 87 74 8 1 2 65 7 82 2 71 62 78.5 1 1.5 75 5 25.5 1 1.5 2 12 8 4 5 53.5 1 1.5 2 12 8 4 47 46 8 6 4 8 DVC 56-POC 88 5977/5978 8 6 5 1 92 93 DVC 63-POC 5974/5975 85 4 92 4 98 96 2 2 15 1 5 65 5 51 73 7 77 1 2 3 92 2 2 4 3 2 1 57 54 74 76 85 9

18 I EC-fans DVG EC, roof fan Up to 4 C/12 min (F4/12, F4/9, F3, F2) Normal ventilation up to 12 C continuous operation Horizontal (DVG-H) exhaust or vertical exhaust (DVG-V) DVG-H DVG-V DVG smoke extract fans are used in case of fire to extract smoke gases from rooms, and also during normal working conditions for standard ventilation. Smoke-free escape ways increase the chances to rescue people in case of fire. The casing is manufactured from seawater resistant aluminium. The base frame consists of galvanised steel. The impeller with backwardcurved blades is manufactured from galvanised steel. Motor outside air stream. In the case of fire switch to fire mode where the bridging of motor protection devices is necessary. B ødf (n x M) ødf (nxm) Max 24 A F øe Max 24 H G B øe H1 A H A H1 A DVG A øb E F G ødf (nxm) H1 H 355 598 45 12 13 74 438 (6xM8) 3 567 45 668 535 12 1261 854 438 (6xM8) 3 637 56 943 75 14 154 178 65 (8xM8) 3 773 63 139 84 14 1573 172 674 (8xM8) 4 858 8 1255 15 14 224 128 872 (8xM8) 4 999 DVG EC H-355/ F4 H-45/ F4 H-56/ F4 H-63/ F4 H-8/ F4 V-355/ F4 V-45/ F4 V-56/ F4 V-63/ F4 V-8/ F4 Voltage V 23 1~ 23 1~ 4 3~ 4 3~ 4 3~ 23 1~ 23 1~ 4 3~ 4 3~ 4 3~ Power W 4 925 242 565 4865 4 925 249 555 479 Current A 1,8 4 3,7 8 7,7 1,8 4 3,8 8 7,7 Max air flow m 3 /s,94 1,724 3,642 5,338 7,673,862 1,612 3,419 5,59 6,978 R.p.m. [min -1] 15 145 14 1455 93 15 145 14 1465 93 Sound power level, 4/1 m db(a) 59/63 67/6 75/69 78/72 81/72 56/5 65/58 72/67 75/69 74/66 Weight kg 41 53 11 11 192 43 57 16 115 199 Insulation class, motor F F F F F F F F F F Enclosure class, motor IP 54 54 54 54 54 54 54 54 54 54

EC-fans I 19 5 1 2 3 8 2 4 6 1 4 8 12 4 DVG-H 355EC/F4 DVG-H 45EC/F4 DVG-H 56EC/F4 6 75 3 4 5 2 1 2 25.25.5.75 1.5 1 1.5 2 1 2 3 4 12 5 1 15 2 1 5 1 15 2 25 5 1 2 3 DVG-H 8EC/F4 9 DVG-H 63EC/F4 75 4 DVG-V 355EC/F4 3 6 5 2 25 3 1 2 4 6 2 4 6 8.25.5.75 1 8 2 4 6 1 4 8 12 12 5 1 15 2 6 DVG-V 45EC/F4 75 DVG-V 56EC/F4 9 DVG-V 63EC/F4 4 5 6 3 2 25.5 1 1.5 2 1 2 3 4 2 4 6 1 5 1 15 2 25 DVG-V 8EC/F4 75 5 25 2 4 6 8

2 I EC-fans TFSR/TFSK EC, roof fan High efficiency EC-motors 1 % speed controllable Potentiometer included Swing-out The TFSR-EC and TFSK-EC roof mounted fans are driven by EC motors and intended for use as extract fans in smaller premises such as self contained flats and apartments as well as storage areas, small workrooms etc. EC-technology is intelligent technology, using integral electronic control to ensure that the motor always runs at optimal load. The fans are delivered with a pre-wired potentiometer(-1v) that allows you to easily select the desired working point. The isolation switch is integrated and there are several alternative roof curbs available as accessories. The tilting mechanism simplifies cleaning and maintenance. Includes electronic motor protection. The horizontal discharge creates smaller internal pressure losses and prevents accumulation of ice on the roof. The protection guard prevents unintentional contact with the impeller. TFSR øc TFSK øc A B A B HC ød E c/c F 36 ø9(4x) TFSR EC A B C D HC 16 147 172 334 38 25 2 15 187 364 439 25 TFSK EC A B øc E c/cf 16 147 172 334 421 33 2 15 187 364 421 33 HC = Hole diameter for fixing, ø6x4 TFSR/TFSK EC 16 2 Voltage/Frequency V/5/6 Hz 23 1~ 23 1~ Power W 81.5 74.6 Current A.64.587 Max. air flow m 3 /s.161.216 R.p.m. min-1 3162 251 Max temp. of transported air C 45 45 when speed controlled C 45 45 Sound pressure level, 3m db(a) 43 43 Weight kg 4.2/4.6 5.4/6.2 Insulation class, motor B B Enclosure class, motor IP 44 IP 44

EC-fans I 21

22 I EC-fans KBR/KBT EC, thermo box 1 % speed controllable Integrated motor protection Low noise level Max temperature of transported air 12 C. KBR-EC fans have impellers manufactured from galvanized sheet steel with backward-curved blades. KBT-EC fans have impellers manufactured from galvanized sheet steel with forward-curved blades. The casing for KBR/KBT-EC are manufactured from double skinned galvanized steel and are insulated with 5 mm mineral wool. KBR/KBT-EC have a swing-out door for easy inspection and servicing. The direction of the door opening can be easily changed from left to right on site. The fan is resiliently mounted with anti vibration mountings which are incorporated in the base frame. A 13 J A J 78 F K C B E D ØG H C ØG B G E D 33 38 L 5 5 38 L 5 5 G 35 H KBR EC A B C D E øg H J L 28 171.5 537 295 36 625 28 234 291 6 315 187.5 6 339 398 69 315 249 37 8 355 26.7 655 372 451 77 355 273 331 77 M KBT EC A B C D E F øg H J K L M 2 142.7 445 249 292 51 13 2 174 232 78 45 35 25 16 5 285 333 576 13 25 213 272 78 6 35 KBR EC 28 315 315-L 355 355-K 355-L KBT EC 2 25 Voltage/Frequency V/5/6 Hz 23 1~ 23 1~ 23 1~ 23 1~ 23 1~ 4 3~ 23 1~ 4 3~ Fan power consumption (P1) W 17 173 1268 498 296 2567 535 1252 Current A.52.771 5.53 2.17 1.3 3.92 2.43 2.1 Max air flow m 3 /s.426.579 1.12.997.822 1.86.554.925 R.p.m. min-1 1512 1512 325 1495 1514 261 1498 137 Max temp. of transported air C 12 12 12 12 12 12 7 12 when speed controlled C 12 12 12 12 12 12 7 12 Sound power level, 4/1 m db(a) 31/23 34/26 49/41 39/31 39/31 52/44 36/28 37/29 Weight kg 47 75 75 81 81 83 35.6 52.5 Insulation class, motor F F F F F F F F Enclosure class, motor IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 IP 55

EC-fans I 23 KBR 28EC KBR 315EC KBR 315EC-L KBR 355EC KBR 355EC-K KBR 355EC-L KBT 2EC KBT 25EC

www.systemair.com Systemair AB May 212 Art no E876