De beste prosjektene fra Tyskland Renovation using Passive House Components



Similar documents
Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Innovative Buildings in Germany and all over the world...

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

The first apartment house renovation with Passive House components in Norway

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

Norwegian Tax Authority - Oslo Norway

Energy Concept and Technology in the Rosenheim Solar Decathlon House

How To Get A Passive House

Case study on residential building renovation and its impact on the energy use and thermal comfort

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Passive house rehabilitation of post war residential building in Zug, Switzerland

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Combi Unit Genius. The energy efficient Building Service Centre

School in Schwanenstadt, Austria

Economic Passive House buildings

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

Heating and Ventilation

Energy savings in the residential area are essential in

Nordic Built Active Roofs and Facades ELLEBO RENOVATION

Sustainable construction criteria to evaluate the thermal indoor climate - further development of the BNB assessment tool and practical implementation

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Energy audit in Finland

Twinning «Improvement of the Energy Efficiency in Turkey»

Improving thermal insulation of concrete sandwich panel buildings

Assessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon

SAP 2012 IN A NUTSHELL

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Case Study Family Room Renovation 3br family home, Melbourne

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Directorate for the Built Environment Building Standards Division

Buildings and Districts as Renewable Energy Source

Achieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008

Solar Thermal Systems

- Smart buildings for smart grids - Univ. Prof. Dr. Ing. M. Norbert Fisch IGS, TU Braunschweig / EGSplan Stuttgart

Project Build with CaRe - WP 2 Education and Training

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Energy efficiency of windows in historic buildings

Comparison between Decentralised and Centralised Air Conditioning Systems

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

BER Assessors Dwellings Technical Bulletin

Integrated Solar Radiant Systems

Building Energy Labels: The Swiss MINERGIE Label

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

Klosterenga, Oslo, Norway, page - 1

Energy-Plus Primary School, Hohen Neuendorf, Germany

Heating and cooling. Insulation. Quick facts on insulation:

Adaptive strategies for office spaces in the UK climate

New technical solutions for energy efficient buildings

The Solar Ice storage system

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Advanced office buildings with efficient technologies in Frankfurt am Main

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

Energy Efficiency HOSPITALITY.

RESSÒ: energy efficiency urban rehabilitation

Energy efficiency of buildings - holistic approach in calculation methods and evaluation

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)

Ecofys VII U-Values for Better Energy Performance of Buildings

Franciscan Monastery, Graz, Austria

9 Energy management. 9:1 General. BFS 2011:26 BBR Oct. 9:11 Scope of application

BER Assessors Dwellings Technical Bulletin

Smart Cities. Integrated approach for innovative technologies. 2nd Annual Conference of the ETP on. Budapest, 6th May 2011

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Low energy class 1 typehouses according to the Danish building regulations

Challenging the possibilities

Passive homes GUIDELINES FOR THE DESIGN AND CONSTRUCTION OF PASSIVE HOUSE DWELLINGS IN IRELAND

How To Make Your House Breathe

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Germany's path towards a nearly climate-neutral residential building stock 2050: Comparison of greenhouse gas mitigation strategies

Clean Energy Solutions Center IEA Technology Roadmap: Energy Efficient Building Envelopes Launch

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Prefabricated Systems for Low Energy / High Comfort Building Renewal

U.S. Department of Housing and Urban Development Office of Public and Indian Housing. A Good Place to Live!

Efficient Buildings Plus Solar

Multi-layer Insulation Blanket for Roofs

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Transcription:

De beste prosjektene fra Tyskland Renovation using Passive House Components Berthold Kaufmann, Passive House Institute, Darmstadt, Germany building stock rehabilitation a general task project(s) from Germany basic passive house conception functional requirements (...we need that!)

Who can help you to start first projects? Passivhaus Institut Dr. Wolfgang Feist www.passiv.de Consulting (design and construction phase) Thermal bridge calculations Thermal simulation (if necessary) Quality assurance Research and Developement Consulting Passivhaus Dienstleistung GmbH workshops and seminars (PHPP etc.) Quality assurance www.passivhaus-info.de www.ig-passivhaus.de www.passivhausplaner.eu Information network for architects, planers and user Databases about projects and players Public relations (press, TV, internet) International Day of the Passive House Planer seminars soon available in english and other languages further education for experts in the field englisch International Congress Center Dresden 2010 May 28 th / 29 th with exhibition and guided tours to Passive Houses in the Dresden area. www.passivhaustagung.de www.passivehouseconference.org

basics: procedure to get a resonable ph building envelope analyse climatic conditions carefully check the energy balance in detail (PHPP) setup a 'passive' building conception take care on costs so that anybody will be able to afford it airtight w/o thermal bridges ventilated required qualities for PH (new built) thermal insulation: U 0,15 W/(m²K) U w 0,8 W/(m²K) mech. ventilation system with heat recovery η 75% outside air waste air avoid thermal bridge effects ψ a 0.01 W/(mK) air tight envelope: n 50 0,6 /h exhaust air supply air heat energy demand 15 kwh/(m²a) maximum heating load 10 W/m² frequency of overheating in summer 10 % 3-pane glazings: U g 0,8 W/(m²K) g-value 50-55 %

airtight w/o thermal bridges ventilated required qualities for PH (old house rehabilitation) Lüftung mit 75% Außenluft WRG Fortluft 1 use thermal insulation Abluft Zuluft 2 get it airtight! 3 use mech. vantilation (with heat recovery) heat energy demand 25 kwh/(m²a) 4 thermal bridges... cellar perimeter balconies...wrap it as good as possible building stock Passive House... with small heating system small (post-air) heater is enough: 1 kw air 21 C surface 9 C Vergleich Bestand-PH outside Temp: -12 C air 21 C surface > 17 C radiator to compensate cold temperatures heating load > 100 W/m² no extra radiator needed max. heat load only 10 W/m²

old house renovation Tevesstraße FF/M Architects: faktor10, Darmstadt client: ABG Frankfurt Holding Scientific monitoring & consultancy: Passivhaus Institut under contract of Hessia ministery of economics traffic and development, Wiesbaden Apartment building Tevesstraße in Frankfurt am Main, DE PROJECT SUMMARY Renovation of two apartment buildings, built in the postwar period. Reduction of annual heat energy demand: 91 %. Almost complied with Passive House Standard SPECIAL FEATURES Ventilation appliance with heat recovery (efficiency >85%) in each apartment. Solar collectors ARCHITECT faktor 10, Gesellschaft für Siedlungsund Hochbauplanung mbh OWNER ABG Frankfurt Holding, Wohnungsbauund Beteiligungsgesellschaft mbh IEA SHC Task 37 Advanced Housing Renovation with Solar & Conservation download of brochures: http://www.iea-shc.org/task37/

site map Tevesstraße: two blocks erected 1930 destroyed 1944 reconstructed 1947-1954 renovation since 1990ies old house renovation Tevesstrasse Frankfurt before... Bauherr: ABG Frankfurt Holding Heating energy demand (PHPP): 290 kwh/m²a Primary energy demand (EnEV): 250 kwh/m²a for heating, domestic hot water, technical electricity Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden

old house renovation Tevesstrasse...afterwards renovation using PH-components client: Architects : ABG Frankfurt Holding P. Grenz, F. Rasch, faktor10, Darmstadt renovation using PH-components WRG WRG WRG WRG thermal insulation good windows thermal bridges wrapped air tight envelope ventilation with heat recovery Bauherr: ABG Frankfurt Holding heating energy demand: primary energy demand: for heating, hot water and technical electricity 17 kwh/m²a 37 kwh/m²a Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden

... well insulated...afterwards Bauherr: ABG Frankfurt Holding before... Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden check the energy balance in detail (PHPP) specific energy flow kwh/m²a losses gains standard building losses gains passive building

old cellar ceiling NOT airtight...first tests to fill cracks... cellar ceiling made airtight low viscosity fluid used as...... connected to inside plaster...levelling material fills all cracks and gaps airtight...

Tevesstrasse renovation outside wall (insulation: 26 cm PS) U AW = 0.122 W/(m²K) Ψ a = 0,062 W/(mK) cellar wall insulated as well cellar deiling (insulation: 8 cm PU) U KD = 0.177 W/(m²K) Gefördert durch das Hessische Ministerium für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden Tevesstrasse renovation outside wall U AW = 0.122 W/(m²K) 13 C Ψ a = 0,062 W/(mK) cellar wall insulated as well cellar ceiling U KD = 0.177 W/(m²K) Gefördert durch das Hessische Ministerium für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden

pedestal of building: cellar wall insulated view inside view from outside Gefördert durch das Hessische Ministerium für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden cellar ceiling and wall from inside (staircase to cellar) Gefördert durch das Hessische Ministerium für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden

thermally insulated window frame... optimized positioning in wall (insulation layer) Ψ o = 0,014 W/(mK) 15,3 C U w = 0,79 W/(m²K) U w,eingebaut = 0,85 W/(m²K) 13,5 C 15,1 C Ψ u = 0,050 W/(mK) Einbau02 Bauherr: ABG Frankfurt Holding Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden Bauherr: ABG Frankfurt Holding Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden new windows pushed out...

new windows pushed out...... gives additional space inside Bauherr: ABG Frankfurt Holding Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden new windows pushed out... the outside aspect ratio: window opening / depth of reveal remains unchanged compared to the situation before Bauherr: ABG Frankfurt Holding Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden

renovation using PH-components thermal bridges optimized Heating energy demand:17 kwh/m²a Primary energy demand:37 kwh/m²a heating, hot water, technical electricity Monitoring of energy consumtion and temperatures over two years showed very good match to theory Gefördert durch das Hessische Ministerium für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden well insulated... heating with supply-air is possible Gefördert aus Mitteln des Hessischen Ministeriums für Wirtschaft, Verkehr und Landesentwicklung, Wiesbaden

We need better air quality! permanent ventilation especially in old houses! The renovated old house with new windows will be much better air tight than before, but inhabitants are not used to cross ventilation. Old house renovation will have (few)more thermal bridges left We need mechanical ventilation for dehumidification! Recommendation: ventilation system only with heat recovery

CO 2 -concentration with only ventilation by windows Friday Saturday 'Shock' ventilation Part 2 Afternoon nap of child EN 13779 (400+1000) ppm Absence Existing old building with window ventilation E-C.1.1 17 10/09 Source: [PHI Pfluger] Author: HK / PHI / PHD CO 2 -concentration with mechanical ventilation Tuesday Wednesday EN 13779 allowed CO 2 -concentration over fresh air concentration: IDA 4 > 1000 ppm IDA 3 600-1000 ppm IDA 2 400 600 ppm Part 2 IDA4 IDA3 IDA2 Measurement values Passive House CO 2 - concentration in a Passive House (Bedroom, measurement Kassel Marbachshöhe winter 2001/2002)

Monitoring of building performance by PHI monitoring for 2 years: temperatures air quality air exchange rates energy consumption space heating hot water Monitoring Tevesstrasse: balance heating distribution losses energy consumption for space heating [kwh/m²a] distribution losses (usable) Heating energy consumption (sum of meters in flats) Heat flow meter total heat production period of balance: May/1/2007 to April/30/2008 T i = 21,8 C total heat space heating separation to various effects download of detailed project documentation (german language) at www.passiv.de

Monitoring Tevesstrasse: balance hot water energy consumption for hot water preparation [kwh/m²a] storage input storage output storage losses hot water distribution losses hot water meters (all flats) circulation solar input hot water input calculated value total uncertainity period of balance: May/1/2007 to April/30/2008 download of detailed project documentation (german language) at www.passiv.de Apartment building Hoheloogstraße in Ludwigshafen, DE PROJECT SUMMARY Renovation of an apartment building, built in 1960. Reduction of annual heat energy demand: 94 %. Almost complied with Passive House Standard SPECIAL FEATURES decentral ventilation appliances with heat recovery, PV ARCHITECT GAG Ludwigshafen am Rhein OWNER GAG Ludwigshafen am Rhein IEA SHC Task 37 Advanced Housing Renovation with Solar & Conservation download of brochures: http://www.iea-shc.org/task37/

and what about costs? passive house & sustainable design will give long term return why emphasize on building envelope? the economic approach: lifetime of envelope components is high 30... 50... 100 years renovation intervalls are therefore long and so innovation cycles are long conclusion: the investor will be fixed to any desicion made now for many years do the best you can afford now

total costs of thermal insulation (wall) extra effort for building envelope renovation...... gives noticable extra benefit for the customer... provides locally added value (no fuel importation)... makes renewables a realistic possibility WRG WRG WRG WRG... is not 'easy' to realize but reasonable Passive Houses building today for a sustainable future

remember Fridtjof Nansens FRAM (1893) the challenge: very cold climate, small ship Fritjof Nansen: "In Nacht und Eis. Die norwegische Polarexpedition", Leipzig 1898 Fridtjof Nansens FRAM Del 1 side 41: Tak, gulv og vegger bestod av mange lag, så det ble tykke og varmeisolerende. Innerst inne mot det varme rommer ble det overalt lagt linoleum, som skulle hindre den fuktige kahyttluften fra å komme ut i siden og der avsette vann, som i tilfelle snart ville fryse til is. Skipssidene ble dekket med tjæret filt, deretter korkfyll, granpanel, et tykkt filtlag, lufttett linoleum og tilslutt enda et panel. Taket (under dekk over salong og kahytter) hadde følgende lag: luft, filt, granpanel, linoleum, (renhårsfyll, granpanel, linoleum, luft, granpanel. Når vi regner med dekksplankene,) var tykkelsen alt i alt omtrent 40 cm. (På gulvet i salongen ble det ovenpå dekksplankene lagt et tykt lag med korkfyll, der over et tykt tregulv og så øverst linoleum.) for å motvirke kulden ble også skylightet bl.a. beskyttet ved tre ruter innenfor hverandre. Del 1 side 129 Det er et varmt hus, "Fram", riktig et koselig hus. Enten det er 30 grader kulde eller 6 grader, har vi ikke noe i ovnen. Og ventilasjonen er førsterangs; (især siden vi rigget opp luftseilet står en hel vinter inn gjennom ventilhullet. Men like fullt sitter vi lunt og godt her med en lampe brennende.) Jeg tenker på å ha ut hele ovnen; den står bare i veien. (Hva beskyttelse mot vinterkulden angår, har da iallfall mine beregninger slått godt til. Vi plages heller ikke stort av fuktighet.) thanks for the norwegian text and some explanations to Trond Haavik, Segel AS, Nordfjordeid (www.segel.no) a passive house described in 1893

Fridtjof Nansens FRAM... besides this, ceilings, floors and walls were made [air] tight and thermal insulating by numerous layers. [nearest to the warm room] on all surfaces there was placed air tight linoleum to prevent from condensation of warm humide air: the humidity would freeze otherwise very soon. The walls are covered with tared felt, followed by cork, then a layer of wood, a layer of felt, then linoleum and again wood. The ceilings [...] have an overall thickness of about 40 cm. The window where the cold could come in very easily was protected by triple panes and other means. This is a warm and comfortable location. Whether the temperature outside is 5 C or 30 C below zero, we don't have any fire in the stove. The ventilation is excellent, for it drives fresh winter air through the fan downwards. I conceive to bring the stove outside, it just stands in the way. " the solution: good insulation & triple pane glazings airtightness & ventilation In night and ice a passive house described in 1893 Fritjof Nansen: "In Nacht und Eis. Die norwegische Polarexpedition", Leipzig 1898 thank you very much for your attention berthold.kaufmann@passiv.de for more information see: www.passiv.de www.ig-passivhaus.de www.passivhaustagung.de Copyright by. This collection of slides (printout) is only for personal use for persons attending the presentation. All other publication only by explicit allowance of PHI.