FIRE CODE INTERPRETATION



Similar documents
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

City of Bettendorf Fire Alarm System Requirements

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

CFAA NCR CHAPTER ANNUAL SENINAR. Commonly Overlooked Fire Alarm Requirements

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

HERNANDO COUNTY FIRE ALARM GUIDELINES

MUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number

Bold items are particular to the City of Euless

How To Install A Carbon Monoxide Detector

Life Safety Code Enabling References

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

2007 ICC FINAL ACTION AGENDA

Low Frequency Notification Appliances

Module 4, Lesson 12 Fire Alarm Systems

BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS

February 2014 Alberta Fire Code Page 1 of 5. Fire Safety and Hand Hygiene in Healthcare Facilities

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

CBD-233. Fire Alarm and Detection Systems

BUILDING DESIGN STANDARDS UNIVERSITY SERVICES ELECTRONIC SAFETY AND SECURITY - DIVISION 28 Fire Alarm Systems

Fire Alarm Systems Requirements by Occupancy Type

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

FIRE ALARM SYSTEM RECORD OF COMPLETION

Fire Alarm System Monitoring - CAN/ULC-S561-03

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

How To Build A Two Hour Firewall In Calgary

Fire Alarm System Plans Review Checklist Property location Date of Review

FIRE CODE INTERPRETATION

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

RHODE ISLAND DIVISION OF STATE FIRE MARSHAL

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

BS5839 Part 1:2002 Overview

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems

CHAPTER 9 FIRE PROTECTION SYSTEMS

PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

PLAN REVIEW GUIDE FOR FIRE ALARM

ACOUSTICAL CONSIDERATIONS FOR EFFECTIVE EMERGENCY ALARM SYSTEMS IN AN INDUSTRIAL SETTING

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.

Commercial Fire Alarm Standards July 1, 2010 Edition Page 1 of 14

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Module 5. Fire and Emergency Alarm System Part I- Basics

DTW Works Master Specification Version 2006

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

Carbon Monoxide Detection in Commercial Buildings (

Standard the the Raising

PLBG/GAS SAFETY Information Bulletin

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

SECTION FIRE ALARM AND DETECTION SYSTEM

Preventative Maintenance For Fire Systems

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

The Mission Critical Fire Protection Experts

946 CMR: MASSACHUSETTS DEVELOPMENT FINANCE AGENCY 946 CMR 7.00: DEVENS REGIONAL ENTERPRISE ZONE FIRE AND POLICE RULES

Carbon Monoxide Alarms

FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

EXHIBIT A SCOPE OF WORK

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Fire. The Fire Installers Mate. A guide to fire alarm systems design

FIRE-FIGHTING DESIGN BRIEF REPORT

Executive Summary Inclusion of Current Firewall Requirements in NBCC

Comparison of the Structural Provisions in the International Existing Building Code 2012 versus the Rhode Island State Rehabilitation Code

Lifetone Technology HLAC150-series Bedside Fire Alarm and Clock Specifications and Features

Sprinkler and Fire Alarm Systems for the Building Official

Mobile Fire Rescue Department Bureau of Fire Prevention

University Design Standard. Fire Alarm Systems

CHAPTER 8. Village of Caledonia Alarm Systems Ordinance ( /01/13)

Noise at the Work Site

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

A. OCCUPANT FIRE PROCEDURES... 3 B. THE TENANT FIRE SAFETY TEAM... 6 C. SENIOR FIRE WARDEN... 7 D. DEPUTY FIRE WARDEN... 8

Overview of Hotel Fire Safety Requirements

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

1.0 General. Inspection, Testing, and Maintenance 1 of 8

SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS

Design Standards Fire Alarm Systems Division (1995 CMS); (2004 CMS) Amended Feb 2015

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM

FIRE DETECTION AND ALARM SYSTEMS

Transcription:

FIRE CODE INTERPRETATION March 2008 ISSUE: Existing Fire Alarm Systems FCI-08-06 Page 1 of 9 The purpose of this bulletin is to identify conditions where a building fire alarm system may be subject to modifications in order to provide or maintain an expected level of protection for occupants. This bulletin applies to fire alarm systems installed in buildings constructed prior to Alberta Building Code (ABC) 1997. Fire alarm systems in buildings constructed under ABC 1997 or subsequent Codes are to meet the Codes in effect. There are 4 factors that influence the degree of changes that may be necessary to a building fire alarm system in order for it to provide the expected level of protection. The factors take into consideration the need for changing systems that were installed to good engineering practice prior to established Codes and standards. The factors also reflect how fire alarm systems installed under established Codes should be regarded when changes are contemplated and to what degree the requirements of the most current Code and standards apply in renovations and changes to the systems. 1. MAINTENANCE Minimum Level of Servicing for a Fire Alarm System Applies to all fire alarm systems Keeps the system functioning to the original design and installation standards and provides for the most part, fault-free operation All parts and devices are tested annually and defective parts are replaced with listed compatible components. This generally applies to field devices such as heat detectors, smoke detectors, audible devices, manual pull stations and end-of-line devices, etc. Defective control panels may be replaced as part of a maintenance procedure ONLY IF THE EXACT REPLACEMENT PANEL IS AVAILABLE TO ENSURE THE ULC LISTING IS NOT COMPROMISED Note: Professional engineering involvement for the replacement of control panels and field devices is not required for normal maintenance of the alarm system. Note: Control Panel Replacement for other reasons such as: old models are no longer available from the manufacturer new panels are needed to accommodate newer field device technology different manufacturer s panel is selected for the system This is no longer considered normal fire alarm system maintenance and now is considered to be a repair of the system. Issue of this Interpretation is authorized under the Alberta Fire Code, Division C, Article 2.2.2.1. by the Chief Fire Administrator [Original Signed] Raymond Ligenza Alberta Municipal Affairs and Housing Safety Services, 16th Floor, 10155-102 Street, Edmonton, Alberta, Canada, T5J 4L4 Safety Codes Council, Suite 800, 10707-100 Avenue, Edmonton, Alberta, Canada, T5J 3M1

2. REPAIR Level of Work Needed to have a Functioning System Applies to fire alarm systems in buildings constructed prior to ABC 1997 Significant repair involving the replacement of the control panel is necessary in order to have the alarm system operate and function as intended It is intended that ABC 1997 or the most current Code requirements not be applied when repairing an existing system, but rather, a piece-for-piece replacement of existing defective devices is necessary to obtain a functioning alarm system, for example: Heat detectors are replaced with new heat detectors Bells are replaced with new audible devices Smoke detectors are replaced with new smoke detectors Control panel is replaced with a newer control panel, etc. New panels and new field devices may incorporate newer technological features such as being addressable and must be compatible for maintaining the ULC listing for example: A 110 volt, 3-wire non-supervised control panel and system is repaired with equipment that operates on 24 volts and is supervised The principle of a repair is to have the system meet and function to the original requirements of the Code and standards applicable at the date of construction. The exception to this rule applies to building constructed prior to ABC 1978, which references the first fire alarm system standard being, CSA-B222.0, Installation Code for Local Fire Alarm Systems. Fire alarm systems installed in building prior to ABC 1978, were designed under good engineering practice and may not be subject to any standard installation methods. Therefore, fire alarm systems installed prior to ABC 1978, should be repaired to meet the minimum requirements prescribed by ABC 1981 which references ULC-S524-M1980, Standard for the Installation of Fire Alarm Systems, or if necessary for apartments, be upgraded to conform to the apartment upgrading guideline. Note: Professional engineering involvement is necessary when repairing existing fire alarm systems where the size and occupancy of the building under ABC 1981 determines professional involvement. Professional engineering involvement may include as little as preparing a scope of work for the building alarm system and a final verification after installation. 3. UPGRADING First Degree of Modification to the Original Fire Alarm System Design Applies to fire alarm systems in buildings constructed prior to ABC 1997. Involves changes to the design of the original system. Upgrading may be initiated voluntarily by the owner as a proactive measure in keeping older buildings safe for occupants, or by upgrading provisions established under the Alberta Fire Code (AFC). Page 2 of 9

Involves the addition of new devices, components, panels, zones, etc., and is intended to incorporate some of the specific barrier free requirements of ABC 1990 such as visual appliances. May be applied to building floors and spaces being renovated for new tenants or occupancies. Upgrading usually involves the integration of new improved devices for better operation and easy trouble shooting of the system. When necessary, fire alarm systems being upgraded should meet the minimum requirements prescribed by ABC 1990, which references ULC-S524-M1986, Standard for the Installation of Fire Alarm Systems. Note: Specific fire alarm system upgrading requirements must be reviewed and accepted by the authority having jurisdiction (AHJ). Note: Professional engineering involvement is necessary for the upgrading of existing fire alarm systems where the size and occupancy of the building under ABC 1990 determines professional involvement. Professional engineering involvement may include as little as preparing a scope of work for the building alarm system and a final verification after installation. 4. REPLACEMENT Second Degree of Modernization to the Original Building Fire Alarm System Design Applies to buildings that undergo complete or extensive modernization involving the gutting out of basic building services and equipment. It is intended to make an old building into a new building. May be initiated by the owner usually as a result of changing the occupancy or use of the building. Note: Where a fire alarm system is completely replaced due to modernization of the building, the new fire alarm system must be a complete new design and is required to meet the intent and application of the most current Building Code in force. OPINION OF RETROACTIVE REGULATIONS Alberta introduced two retroactive regulations for upgrading fire alarm systems: (1) Smoke Detector Regulations A.R. 129/77 (2) Controlled Buildings & Residential Occupancy Buildings Regulation A.R. 317/79 The following is an opinion on the application of Alberta s retroactive regulations: Alberta Regulations 129/77 and 317/79, even though they have been repealed, remain in force and are deemed to have been made under the new enactment (the Fire Code) provided the requirements are not inconsistent with the new Fire Code. Interpreted from Section 32(1)(e) of the Interpretation Act. Page 3 of 9

Although the new Code is more stringent, it should not be interpreted as being inconsistent with the previous regulations. The current Fire Code provides for acceptance of an existing building or fire protection measure which brings A.R. 129/77 and A.R. 317/79 within the parameters of Sentences 1.1.2.3.(1) or (2) of the AFC 1997. This means, that where a building was upgraded or accepted as complying with A.R. 129/77 and/or A.R. 137/79, the provisions of the ABC 1997 is deemed to have been complied with. If anything does not fall within the scope of Sentence 1.1.2.3.(1) of the Fire Code, then Sentence 1.1.2.3.(2) provides that existing building or fire protection measures constructed may be permitted so long as there is a degree of life safety acceptable to the authority having jurisdiction or measures are taken to provide a degree of fire safety that is acceptable to the authority having jurisdiction. Sentence 1.1.2.3.(1) can be interpreted as restricting the retroactive application of the AFC as this would be prejudicial to owners of residential occupancies to upgrade fire alarm systems to meet the requirements of each new Building Code. APPLICATION OF NEW CODE REQUIREMENTS TO FIRE ALARM SYSTEMS THAT ARE BEING UPGRADED OR REPLACED Owners, designers and the authority having jurisdiction (AHJ) should determine the original design parameters and standards for an existing fire alarm system as outlined in Appendix A of this bulletin. When dealing with existing conditions, the AHJ may determine if other measures are needed to provide an acceptable degree of fire alarm system audibility and reliability. In cases where fire alarm systems are being replaced due to the modernization of a building, all provisions of ABC 1997 would apply. ANALYSIS PROCEDURE: Several factors need to be considered when determining the existing safety level of an alarm system and the degree of any proposed changes. 1. Is the alarm system in safe and operable working condition? 2. What year was the building constructed? 3. What Regulations or Code originally applied to the building? 4. Are upgrading guidelines being applied to the building? 5. Have changes to the building affected the design or safety of the original system? 6. Determining the extent of new Code requirements applicable in providing an acceptable degree of safety. APPLICATION OF AUDIBILITY REQUIREMENTS TO FIRE ALARM SYSTEMS THAT ARE BEING RENOVATED OR UPGRADED Designers and the authority having jurisdiction (AHJ) should determine the original design parameters and standards for an existing fire alarm system. Appendix A of this bulletin details the Code requirements in place for a specific time period. When dealing with existing conditions, the AHJ may determine if the degree of audibility and life safety is acceptable or that other measures are needed to provide an acceptable degree of fire alarm system audibility. Page 4 of 9

AUDIBILITY LEVELS The ABC 1997 introduced a requirement affecting the audibility levels of fire alarm systems in residential occupancies. The new Code prescribes 75 dba as the specific sound pressure level to be achieved in the sleeping room of a residential occupancy. The National Research Council (NRC) Appendix note explains that an additional audible device in a suite would be necessary when the sound pressure level of corridor devices exceed 110 dba in order to be heard within the suite. The standard established by the new Code is necessary as a result of increased sound barrier levels now required between residential suites and public corridors. Many owners, designers, building and fire safety authorities are questioning the 75 dba audibility level as it is applied to existing apartment buildings and especially for those that are upgrading a fire alarm system. Fire alarm system audibility has been a requirement of the National Building Code (NBC) prior to the first edition of the ABC in 1974. Audibility requirements were originally prescriptive applying a specific size of device for a specific coverage of floor area. Appendix A describes in detail the specific audibility requirements for fire alarm system installed in pre-1974 buildings and for those buildings constructed under the ABC between the period of 1974 up to 1997. Page 5 of 9

APPENDIX A Code Summary of Fire Alarm System Audibility Requirements National Building Code 1970 established the following audibility standards. These standards applied to buildings constructed prior to and under the Alberta Building Code 1974. Fire alarm signals shall be distinctive in quality and pitch, and sufficiently loud to be heard above the normal noise level within the area served by the alarm Alarm gongs used as alarm sounding devices shall be located so as to provide at least a) one 4-in. diameter (102 mm) gong for each 1,000 sq ft (93 m² ) of floor area, b) one 6-in. diameter (152 mm) gong for each 5,500 sq ft (511.5 m² ) of floor area, or c) one 10-in. diameter (254 mm) gong for each 12,000 sq ft (1116 m² ) of floor area. The standards established under Alberta Building Code 1978 are: Audible signal appliances shall be installed in each corridor and in such other locations as may be required and be sufficiently loud to be heard above the normal noise level within the area served by the appliance. The standards established under Alberta Building Codes 1981, 1985 and 1990 are: Audible signal appliances forming part of a required fire alarm system shall be installed in a building so that alert signals, alarm signals and voice messages can be heard intelligibly throughout the floor area in which they are installed. Audible signal appliances shall be installed in each corridor and in such other locations as may be required and be sufficiently loud to be intelligibly heard by all occupants within the area served by the appliance. Each of the referenced ULC Standards S524 Installation of Fire Alarm Systems contained information on suggested sound pressure levels. The information was intended to provide design guidance and is as follows: a) For alarm or alert signals at least 15 dba above the equivalent sound level or 5 dba above the maximum sound level having a duration of at least 60 seconds whichever is greater, measured 1 500 mm above the floor, but not less than 90 dba. b) For voice communication at least 9 dba (ABC 81 and 85) or 15dBA (ABC 90) above the equivalent sound level or 3 dba above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 1 500 mm above the floor, but not less than 85 dba. c) For the purpose of this clause, the equivalent sound level is the averaged, A-weighted sound pressure level measured over a 24 hour period under normal occupancy conditions. Page 6 of 9

Alberta Building Code 1997, Article 3.2.4.19., establishes a decibel measurement for the audibility of alarm systems. Audible signal devices forming part of a fire alarm system shall be installed in a building so that alert signals and alarm signals are clearly audible throughout the floor area in which they are installed. The temporal pattern of an alarm signal shall conform to the temporal pattern defined in Clause 4.2 of International Standard ISO 8201, "Acoustics - Audible emergency evacuation signal." The signals from smoke alarms and the patterns of alert signals shall be sufficiently different from the signals or patterns of alarm signals to ensure that there is no possibility of confusion. The fire alarm signal sound pressure level shall be not more than 110 dba in any normally occupied area. The sound pressure level in a sleeping room from a fire alarm audible signal device shall be not less than 75 dba in a building of residential occupancy when any intervening doors between the device and the sleeping room are closed. The sound pressure level from a fire alarm audible signal device in a floor area used for occupancies other than residential occupancies shall be not less than 10 dba above the ambient noise level, but with a minimum value not less than 65 dba. Fire alarm audible signal devices shall be supplemented by visual signal devices in any floor area in which a) the ambient noise level is more than 87 dba, or b) the occupants of the floor area i) use ear protective devices, ii) are located within an audiometric booth, or iii) are located within sound insulating enclosures. The above shall also apply in an assembly occupancy in which music and other sounds associated with performances could exceed 100 dba An audible signal device located within a dwelling unit shall incorporate a means that enables the device to be silenced for a period of not more than 10 min, after which the device shall restore to normal operation. An audible signal device located within a dwelling unit or a suite of residential occupancy shall be connected to the fire alarm system in a manner that disconnection of, or damage to, that device will not interfere with the ability of devices in other dwelling units, public corridors, or suites to sound an alarm. Audible signal devices referred to in the above sentence are not required to have individual electrical supervision. Audible signal devices shall be installed in a service space referred to in Sentence 3.2.1.1.(7) of the ABC 1997 and shall be connected to the fire alarm system. Page 7 of 9

06-FCI-006 REPLACEMENT Owner decides to replace entire system as a single building component or through building modernization Owner must comply with ABC 1997 Pre ABC 1978 Fire Alarm Systems Installed to CSA Standards Smoke Detector Regulation, and Controlled Building Regulation System is Not Working Safely System unreliable Fire or shock hazard Will not detect or alert building occupants REPAIR Piece for piece replacement of components and panels OR UPGRADE Compliance to ABC 1990 or Compliance to Apartment Upgrading Guideline Maintenance System is maintained in safe working order Replacement of devices and components to ensure safe reliable operation No Further Action Required Page 8 of 9

06-FCI-006 REPLACEMENT Owner decides to replace entire system as a single building component or through building modernization Owner must comply with ABC 1997 Fire Alarm Systems Installed in Accordance with ABC 1978 ABC 1981 ABC 1985 ABC 1990 System is Not Working Safely System unreliable Fire or shock hazard Will not detect or alert building occupants REPAIR As a minimum the owner shall comply with the requirements established under the original Code of construction Piece for piece replacement of components and panels OR UPGRADE Compliance to ABC 1990 or Compliance to Apartment Upgrading Guideline Maintenance System is maintained in safe working order Replacement of devices and components to ensure safe reliable operation No Further Action Required Page 9 of 9