1 A P P L I C A T I O N S G U I D E Low Frequency Notification Appliances
2 APPLICATIONS GUIDE: LOW FREQUENCY NOTIFICATION APPLIANCES Low Frequency Notification Appliances Contents Introduction...3 Waking Effectiveness and the Development of Low Frequency Requirements...3 Awakening of Sleeping People a Decade of Research...3 NFPA-Funded Research on Waking Effectiveness...3 Low Frequency Requirements in NFPA Chapter Chapter Chapter Impact on NFPA Chapter Chapter Voice Evacuation Requirements...5 Impact on the International Building (IBC) and Fire Code (IFC)...5 Impact on Occupancies...5 Group-R1/R2...5 Group-R3...6 Group-R4...6 Power Supply Considerations...6 System Applications...7 Local vs. General Notification...7 Household Fire and Carbon Monoxide Systems...7 References...7 Impact on UL Standards...4 2
3 S Y S T E M S E N S O R Introduction NFPA-Funded Research on Waking Effectiveness The purpose of this guide is to provide information about low frequency 520 Hz notification appliance requirements used in fire alarm and carbon monoxide systems. It outlines the development of the NFPA 72, NFPA 720 and UL standard requirements. It also provides an overview and guidance for placement and usage of low frequency notification appliances within fire alarm and carbon monoxide systems. Though this information is based on industry expertise, it is intended to be used only as a guide. The requirements of applicable codes and standards, as well as directives of the Authorities Having Jurisdiction (AHJ) should be followed. In particular, following the most current versions of NFPA 72 and NFPA 720 for installation and testing of systems is key to the effectiveness of low frequency notification appliances. Section 1 Waking Effectiveness and the Development of Low Frequency Requirements While fire alarm systems and smoke alarms provide life-saving value for people when they are awake, their greatest potential benefit may be when occupants are asleep. This is illustrated in a 2010 U.S. Fire Administration study 1 that reports 50 percent of fire fatalities in residential buildings occur between the hours of 10 p.m. and 6 a.m. the time when most people are sleeping. Further, fatal fires peak between 4 a.m. and 5 a.m. 1 Many NFPA 72 Technical Committee members were concerned about the waking effectiveness of the standard 3 KHz alarm signal for people with hearing loss, the elderly, school-aged children, and the alcohol impaired. In 2006, NFPA petitioned the Fire Protection Research Foundation (FPRF) to carry out research studies to focus on the effectiveness of the standard fire alarm signal for certain high-risk groups. Working with Dr. Bruck, they funded two studies: Waking Effectiveness of Alarms for Adults Who Are Hard of Hearing and Waking Effectiveness of Alarms for the Alcohol Impaired. The goal of these studies was to optimize the performance requirements to meet the needs of these high-risk groups. Study participants were exposed to a range of signals across two non-consecutive nights while they were asleep. The six signals tested were: Hz square wave signal Hz square wave signal 3. Pure tone 3 KHz signal 4. Bed shaker 5. Pillow shaker Most unimpaired adults wake up quickly to the standard audible 3 KHz fire alarm signal, even at levels well below 75 dba. 2 But according to the U.S. Fire Administration study, 13 percent of fire fatalities in residential buildings are occupants less than 10 years old. It is also suspected that over 27 percent of civilian fire fatalities in residential building fires are linked to alcohol (a sedative that can increase arousal thresholds), drug, or chemical influence. After testing these signals, the FPRF studies concluded: The low frequency 520 Hz square wave signal is the most effective by waking up 92 percent of hearing-impaired participants when presented at or below 75 dba for 30 seconds. The standard 3 KHz signal woke up 56 percent at or below 75 dba. If we know most adults wake up quickly to the standard audible fire alarm signal, the U.S. Fire Administration study results beg the following question: How effective is the standard signal at waking high-risk segments of the population, such as school age children, occupants experiencing some form of chemical or alcohol impairment, or people who are hard-of-hearing? 3 Awakening of Sleeping People a Decade of Research In 2008, Dr. Dorothy Bruck released a compilation of a decade s worth of research at Victoria University on the effectiveness of various alarm signals for awakening people. During this study, Dr. Bruck ran numerous experiments using different types of signals to determine their waking effectiveness for healthy adults and high-risk groups. Of all the signals tested, the low frequency signal with a fundamental frequency of 520 Hz was most effective at waking the majority of participants. Specifically, the low frequency signal was found to be 6 to 10 times more effective at waking people than the standard alarm signal. In adults with hearing loss, it was more than 6 times as effective as the standard signal and more effective than bed and pillow shakers. The low frequency 520 Hz signal is superior to bed shakers and pillow shakers at waking hearing impaired participants. Section 2 Low Frequency Requirements in NFPA 72 The low frequency 520 Hz requirements were fully adopted into the 2010 edition of NFPA 72 and subsequent editions. The compliance date for the new requirement was set for January 1, 2014, which provided a five-year window for Nationally Recognized Test Laboratories (NRTLs), such as UL, FM, and ETL to develop test requirements for product standards. This time frame also gave manufacturers time to develop products to comply with the product standards. The new NFPA 72 low frequency 520 Hz requirements are found in Chapters 18, 24, and 29. The following provides an overview for the low frequency requirements in each of these chapters. Chapter 18 Chapter 18 covers the audible alarm signal requirements that are part of a protected premises fire alarm system. The requirements in Chapter 18 do not cover the audible alarm signal produced by a smoke alarm or a household fire alarm system. Section under Sleeping Area Requirements, took effect on January 1, This section establishes that the audible fire alarm signal in sleeping spaces must be low frequency. 3
4 APPLICATIONS GUIDE: LOW FREQUENCY NOTIFICATION APPLIANCES In the 2013 edition of NFPA 72, the text was slightly modified to clarify that the low frequency 520 Hz requirement is only for sleeping spaces and for the purpose of awakening occupants. Some examples of spaces covered by this requirement are hotel guest rooms and college and university dormitory sleeping rooms. The Chapter 18 Committee chose to apply the requirement to all sleeping areas, not just those where occupants have self identified as having a hearing impairment. This was done for the following reasons: Many people are not aware they have a hearing impairment. The low frequency signal has also proven to be very effective at waking people impaired by alcohol third bullet The low frequency signal is effective at waking up school age children. Chapter 24 Chapter 24 covers Emergency Communications Systems (ECSs), such as in-building fire emergency alarm communication (EVAC) systems and mass notification systems (MNSs). Chapter 24 requirements cover occupancies that use a voice system for occupant notification instead of horns as part of an ECS. NFPA 72:2010 Section under Voice Evacuation Messages establishes that sleeping spaces must include a low frequency (520 Hz square wave) pre-alert tone to accommodate hearing impaired individuals. In NFPA 72: 2013, the section was changed to Section and the text was modified to the following: * Except as specified in , in occupancies where sleeping accommodations are provided and the voice message is intended to communicate information to those who could be asleep, a low-frequency tone that complies with shall be used. This section states that if you are using speakers in sleeping spaces as part of your ECS, the low frequency 520 Hz signal is required to play first to wake people who could be asleep, followed by a voice message, except in occupancies listed in The reason for this provision is to comply with the NFPA 72 and UL 864 requirement for the voice evacuation message to be preceded by two cycles of the temp 3 audible alarm signal. Section does not require a low frequency 520 Hz signal in occupancies where the voice system is used to communicate to occupants who are awake. For example, in a hospital, the voice message is used to notify staff members who are already awake. The staff will then respond to the appropriate location in the hospital to carry out their duties, which could include waking and relocating patients who could be in danger. Chapter 29 Chapter 29 covers all occupancies that are required to install smoke alarms or household fire alarm systems. Low frequency 520 Hz requirements have been added for household fire alarm systems and single and multiple-station smoke alarms. Section of NFPA 72: 2010 establishes that in these applications, notification appliances provided for hearing impaired individuals must produce a low frequency alarm signal where required by governing laws, codes, or standards and where provided voluntarily for those with hearing loss. It mirrors the Chapter 18 square wave and 520 Hz frequency requirements and also establishes a minimum 75 dba at the pillow, 15 db above average ambient, or 5 db above maximum sound level (whichever is greater). Duration of the signal must be at least 60 seconds. The NFPA 72: 2013 was modified to clarify that low frequency alarm signals are only required in the sleeping spaces. The Chapter 29 committee took a different position than Chapter 18 and decided to only require the low frequency signal in sleeping spaces for those that are classified to have mild-to-severe hearing loss. Section 3 Impact on NFPA 720 NFPA 720 is the Standard for the installation of Carbon Monoxide (CO) Detection and Warning Equipment. The 2012 and 2015 editions of NFPA 720 has also incorporated low frequency 520 Hz requirements in Chapters 6 and 9. Compliance for NFPA 720 was set for January 1, Chapter 6 Chapter 6 covers audible alarm signal requirements that are part of a protected premise carbon monoxide or fire alarm detection system. The requirements in Chapter 6 do not cover audible alarm signals produced by a carbon monoxide alarm or a household carbon monoxide system. Like Section of NFPA 72: 2010/2013, NFPA 720 Section under the sleeping area requirements establishes low frequency alarm signal requirements centered around a 520 Hz square wave. The new low frequency requirements become effective January 1, Chapter 9 Chapter 9 covers all occupancies that are required to install carbon monoxide alarms or household carbon monoxide detection systems. Low frequency 520 Hz requirements have been added for household carbon monoxide detection systems and single- and multiple-station carbon monoxide alarms. Section establishes requirements for notification appliances provided for the hearing impaired and mirrors those requirements established in NFPA 72: 2010/2013 Chapter 29, Section Section 4 Impact on UL Standards In 2012, UL incorporated performance requirements into two product standards. The first standard of significance to low frequency requirements is ANSI/UL 464, Standard for Audible Signal Appliances, which is primarily used for horns and sounders. The second is ANSI/UL 217, Standard for Single and Multiple Station Smoke Alarms, to which residential smoke alarms are listed. The determination of the low frequency signal format is the same within ANSI/UL 464 and ANSI/UL 217. Per ANSI/UL 464, Section 24.3 describes the signal format requirements. These consist of analyzing the odd harmonics (F1,F3,F5,F7) using a spectral analysis to ensure that the signal is of a square wave format. While evaluating the odd harmonic profile, UL is looking to ensure that the first harmonic is within 520 Hz 10% at its highest db output. Each subsequent harmonic must follow a sequence of 5 db less than the highest peak but no less than 20 db at its third harmonic, no less than 30 db at its fifth harmonic, and no less than 50 db at its seventh harmonic. (See FFT Response of Low Frequency (520 Hz) Notification Appliances). 4
5 S Y S T E M S E N S O R Common spaces are the corridors, lobbies, or meeting rooms. Tenant spaces are dwelling units within apartment buildings, guest rooms of hotels, or dormitory sleeping rooms. The NFPA 72: 2010 is referenced in Chapter 80 of the IFC and Chapter 35 of the IBC. The requirements in NFPA 72 and section of the IFC do not apply retroactively to existing systems. However, there are situations when an AHJ may require an existing system to be brought up to current criteria even though the system still meets the minimum requirements of the version of the code in effect at the time of the original installation. FFT Response of Low Frequency (520 Hz) Notification Appliances The evaluations of these new product requirements are very similar to the profile of speakers for fire alarm systems but with a very specific focus within the 520 Hz frequency range. Products that are evaluated and listed to the low frequency requirements shall be permanently marked on the housing as a low frequency sounder for ANSI/UL 464 compliance or a low frequency alarm for ANSI/UL 217 compliance. The marking requirements were added to distinguish the low frequency notification appliance from traditional devices that do not use a 520 Hz frequency. Section 7 Impact on Occupancies The low frequency requirement applies to new sleeping spaces across several residential Group R occupancies, including lodging or rooming houses, hotels and motels, and dormitories, apartment buildings, and residential board and care facilities. Group R Description Examples 1 Occupancies that are transient in nature Hotels and Motels Section 5 Voice Evacuation Requirements The use of speakers and amplifiers with fire alarm systems is another way to meet the new low frequency 520 Hz requirements. For a voice system to be listed for low frequency applications, the low frequency alert tone needs to be tested as compatible with the voice system and evaluated per the low frequency requirements defined in UL 464, Section This means that the Fire Alarm Control Panel (FACP) manufacturer must list in its literature the compatible manufacturers of speaker(s), amplifier(s), as well as a specific low frequency sound file that has been approved and listed as compatible with the low frequency 520 Hz requirement. This has caused some confusion because many speakers and amplifiers are approved within a frequency range of 400-4,000 Hz and some manufacturers market products with wider frequency ranges. The reason for the compatibility requirement is that historically speakers listed to ANSI/UL 1480 and amplifiers listed to ANSI/UL 1711 can only be listed within a frequency range of 400-4,000 Hz. Nationally Recognized Testing Laboratories (NRTLs) such as UL, will perform their test requirements across these manufacturers listed frequency ranges and they will take an average response across the range. They will not focus on any one specific frequency during their evaluation, which is very different from the requirements defined in 24.3 of ANSI/UL 464 and ANSI/UL 217, which have specific testing requirements on the 520 Hz ± 10% frequency range. Section 6 Impact on the International Building (IBC) and Fire Code (IFC) Section in the 2012 and 2015 edition of the IBC/IFC requires a fire alarm system to be installed in new buildings in accordance with NFPA 72 and to provide occupant notification in accordance with Section The basic purpose of a fire alarm system is to alert all occupants in the building. Section requires the activation of a fire alarm system to send a signal to the control unit and then provide occupant notification throughout all occupied areas of building, including both common and tenant spaces Group-R1/R2 Occupancies containing sleeping units or more than two dwelling units where occupants are more permanent in nature Congregate living facilities with 16 or fewer occupants that provide accommodation for five or fewer persons of any age for less than 24 hours Intended for occupancy as residential care/assisted living facilities including more than five but not more than sixteen occupants, excluding staff College and University Dormitories, Boarding Rooms Daycare Facilities Assisted Living Facilities The low frequency 520 Hz signal is required to be installed in sleeping units of motels and hotels where there is a protected premises fire alarm system to activate the occupant notification system. The purpose of the protected premises fire alarm system is to alert all occupants in the building, including those in sleeping units. However, exception 1 of exempts a protected premises fire alarm system in buildings not more than two stories where all individual sleeping units have an exit directly to a public way. The low frequency 520 Hz signal is also required to be installed in sleeping units of college and university dormitories where there is a protected premises fire alarm system to activate the occupant notification system. The protected premises fire alarm system is required to produce the low frequency 520 Hz signal in the sleeping unit. The smoke alarm is required to produce the low frequency signal as well, either by activating the protected premises fire alarm system or by activating the integral low frequency notification appliance.
6 APPLICATIONS GUIDE: LOW FREQUENCY NOTIFICATION APPLIANCES Group-R3 This occupancy is only required to install smoke alarms in sleeping units. A protected premises fire alarm system is not required. The low frequency 520 Hz signal is not required if there is trained staff to wake up people who are sleeping. The low frequency 520 Hz signal is required if there is not trained staff to wake up people sleeping. Group-R4 This occupancy is intended for residential care/assisted living facilities including more than 5 but not more than 16 occupants, excluding staff. If there is no trained staff, see the requirements for Group-R1/R2 for the low frequency 520 Hz requirements. The low frequency 520 Hz signal is not required if there is trained staff to wake up people sleeping. Section 8 Power Supply Considerations Because of the comparatively high current draw of low frequency 520 Hz devices, the selection of the power supply and accurate voltage drop calculations are critical to ensuring adequate current to the loop. Manufacturers cannot meet the low frequency 520 Hz requirements using the traditional electro-mechanical piezo element because it cannot effectively produce the harmonics needed to comply with the 520 Hz requirements as defined per UL 464, Section Instead, a speaker element, which inherently draws more current than a traditional piezo element, is used to acoustically meet the 520 Hz requirements. As a result, current draw for low frequency devices when compared to devices with a standard alarm tone can be higher. The low frequency 520 Hz signal is only required for the sleeping spaces, not hallways or corridors. The code does not preclude the use of low frequency devices throughout a building, including non-sleeping spaces, but the high current draw of the devices can make this a higher cost approach. Correspondingly, some designers and installers may be concerned that using traditional devices in non-sleeping spaces like hallways with low frequency devices in the sleeping spaces will create different tones between the sleeping room and the hallway. However, the code does not require that tones throughout a building sound the same. What it does require is that the tones synchronize within the same notification zone. Section 9 System Applications Given that in a hotel guest room you may encounter smoke alarms or combination alarms in conjunction with horns or speakers, there is confusion on how systems need to be designed to comply with the requirement. As with any new standard, time is needed for every product in a sleeping space to comply with the new requirement. Below are some recommendations for low frequency applications based on what is available in the market. Local vs. General Notification Using a low frequency notification appliance in each room that is connected to the fire alarm panel s notification appliance circuit is required to give general evacuation notice. In most sleeping spaces, especially in R-1/R-2 occupancies, installers and designers should provide local notification before general notification, in case someone burns popcorn or smokes in the space, for example. Given that many smoke alarm manufacturers in the industry have not released products that comply with the low frequency requirement that can give local notification, installers and designers can utilize a control module to tie a number of rooms together to provide general evacuation. In sleeping spaces, it is recommended to use a smoke detector or a combination detector with no audible sounder base with the low frequency notification appliance, providing general notification only. The current required by the low frequency devices being used will determine how many rooms you can connect to the control module. The use of low frequency sounder base with a system-connected smoke detector or combination detector can provide both local and general notification without the use of additional modules. Household Fire and Carbon Monoxide Systems If you are using a low frequency notification appliance in conjunction with a household fire alarm or carbon monoxide system with a smoke or CO alarm, then the traditional 3 KHz tone may go off for local notification. If the situation requires general evacuation, then the low frequency tone may go off from the notification appliance in addition to the 3 KHz tone of the smoke or CO alarm. Note: System Sensor does not approve, inspect, or certify any installations, procedure, equipment, or materials. In determining the acceptability of installations or procedures, equipment, or materials, the authority having jurisdiction may base acceptance on compliance with NFPA or other appropriate standards. The authority having jurisdiction may also refer to the listings or labeling practices of an organization concerned with product evaluations that is in a position to determine compliance with appropriate standards for current production of listed items. The information in this guide has been provided in an attempt to assist in making this decision and should in no way be constructed as a formal approval or certification. 6
7 S Y S T E M S E N S O R References 1 Topical Fire Report Series- Volume 13, Issue 1/February Civilian Fire Fatalities in Residential Buildings ( ). 2 In a 2008 study (Comparison of the Effectiveness of Different Fire Notification Signals in Sleeping Older Adults - Fire Technology 2008) conducted by Dr. Dorothy Bruck of Victoria University, the standard audible fire alarm signal was classified as a 3 KHz signal. The majority of fire alarm horns in the industry produce an alarm signal with a frequency range between 2 KHz and 4 KHz. Also, the integral sounders in nearly all residential smoke alarms produce a signal with a frequency of 3 KHz. 3 According to Cruickshanks et al, 1998, there were more than 34.5 million people in the U.S. who were classified as hard of hearing in 2007, and 12 percent of people aged 45 years or more are unaware of their hearing problem. This number was expected to increase as the population ages. 4 Awakening of Sleeping People a Decade of Research, Ian Thomas and Dorothy Bruck July The System Sensor Voltage Drop Calculator application for SpectrAlert Advance notification appliances can be accessed at: 7
8 APPLICATIONS GUIDE: LOW FREQUENCY NOTIFICATION APPLIANCES 2014 System Sensor. The company reserves the right to change specifications at any time. AVAG /14
Technological Advances in Smoke Alarms
Technological Advances in Smoke Alarms Introduction Smoke alarms are designed to detect a fire in its early stages and alert people so they have time to safely escape the dwelling unit or building. The
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
How To Install A Carbon Monoxide Detector
NASSAU COUNTY FIRE COMMISSION OFFICE OF THE FIRE MARSHAL Nassau County Public Safety Center 1194 Prospect Avenue Westbury, New York 11590 (516) 573-9900 / nassaucountyny.gov Chief Fire Marshal Scott D.
Module 4, Lesson 12 Fire Alarm Systems
Student Manual Module 4, Lesson 12 Fire Alarm Systems Performance Objectives At the conclusion of this lesson, you will be able to: Identify the components and functions of a fire alarm system and determine
OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety
OHIO BOARD OF BUILDING STANDARDS Smoke Alarms and Fire Safety Updated January 2016 2 UNDERSTANDING THE TERMINOLOGY Detector. An initiation device suitable for connection to a circuit that has a sensor
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:
FIRE CODE INTERPRETATION
FIRE CODE INTERPRETATION March 2008 ISSUE: Existing Fire Alarm Systems FCI-08-06 Page 1 of 9 The purpose of this bulletin is to identify conditions where a building fire alarm system may be subject to
908.7 (New) [IBC [F] 908.7 (New)], 4606.1 (New), Chapter 47 (IBC Chapter 35)
Page 20 ABOUT CODE CORNER CCFS would like to remind you to check with your local Authority Having Jurisdiction (AHJ) for questions and opinions concerning your local Fire and Building Codes. The information
City of Bettendorf Fire Alarm System Requirements
City of Bettendorf Fire Alarm System Requirements Section 907 of the 2009 Edition of the International Fire Code (IFC) and Section 10-7-3 of the Municipal Code provide fire alarm requirements. IFC Section
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL Smoke Alarm and Carbon Monoxide Brochure JOHN E. CHARTIER STATE FIRE MARSHAL 118 PARADE STREET PROVIDENCE, RI 02909 DAYS 401-462-4200 24 Hr. 401-222-2331 FAX#
Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors
Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable
ICC CODE CORNER 2012 IFC Code & Commentary
SECTION 908 EMERGENCY ALARM SYSTEMS 908.1 Group H occupancies. Emergency alarms for the detection and notification of an emergency condition in Group H occupancies shall be provided as required in Chapter
FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION
PERMITS AND INSPECTIONS FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION 911 Assigned PROJECT LOCATION Subdivision: Lot: Blk: Sec: PROJECT New Construction Addition/Remodel Demolition Other: Number
The Mission Critical Fire Protection Experts
The Mission Critical Fire Protection Experts Protection Systems Protection Systems HFC-227ea / FM200 / FE-227 FE-25 / ECARO-25 Novec 1230 Inergen / Argonite Halon Drop-in Systems High and Low Pressure
CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002
CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE 1999 2002 Three new chapters were added. What was chapter 1 in 1999 was reorganized into chapters 1 (Fundamentals), 2 (Referenced Publications), and 3 (Definitions).
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,
Lifetone Technology HLAC150-series Bedside Fire Alarm and Clock Specifications and Features
Lifetone Technology HLAC150-series Bedside Fire Alarm and Clock Specifications and Features 1. INTRODUCTION AND DEVICE CLASSIFICATION 2. PRODUCT SAFETY LISTINGS 3. STANDARDS AND REGULATORY COMPLIANCE 4.
Effective June 27, 2015. TEXT (CO Detection Commercial Buildings)
TEXT (CO Detection Commercial Buildings) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows: Section 1228.4. Carbon Monoxide Detection in Commercial Buildings (a)
How To Make A Fire Alarm System More Effective
$20.00 The Fire Alarm Requirements NFPA 72 & 101 ANSI 117.1 ADAAG Gentex Corporation Fire Protection Products Group 10985 Chicago Dr. Zeeland, MI 49464 1-800-436-8391 1-800-436-8392 (fax) As one of Gentex
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 24.00: FIRE WARNING SYSTEMS INSTALLED IN BUILDINGS WITHIN THE COMMONWEALTH OF MASSACHUSETTS Section 24.01: Purpose 24.02: Scope 24.03: Definitions 24.04: Approval of Design 24.05: Power Supply
Life Safety Code Enabling References
SUPPLEMENT 4 Life Safety Code Enabling References Editor s Note: Supplement 4 provides users of NFPA 72, National Fire Alarm and Signaling Code, with a summary of requirements from NFPA 101, Life Safety
TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows:
TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section 1228.4, to read as follows: Section 1228.4. Carbon Monoxide Detection in Commercial Buildings
DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION
Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier
University Design Standard. Fire Alarm Systems
University Design Standard Fire Alarm Systems 1.0 Overview This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit
Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems
Sam Docknevich, PSP, Security Service Portfolio Manager Are You Prepared? The impending impact of Code on Servicing Security Systems usa.siemens.com/infrastructure-cities Share current and upcoming standards
Overview of Standards for CO Detection Products
Overview of Standards for CO Detection Products Rev 1.1 INTEC Controls 12700 Stowe Dr., Suite 100 Poway, CA 92064 The Right Choice [email protected] www.inteccontrols.com Phone: (858) 578-7887 Fax:
Carbon Monoxide Detection in Commercial Buildings (
1 Technical Guideline for School Districts and BOCES to comply with regulations for Carbon Monoxide Detection in Commercial Buildings (Section 1228.4 of Part 1228 of Title 19 NYCRR). General: This document
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
2007 ICC FINAL ACTION AGENDA
907.2.1.1 System initiation in Group A occupancies with an occupant load of 1,000 or more. Activation of the fire alarm in Group A occupancies with an occupant load of 1,000 or more shall initiate a signal
Carbon Monoxide Alarms
Carbon Monoxide Alarms At its meeting held on December 16, 2009, the State Fire Prevention and Building Code Council determined that adopting this rule on an emergency basis was required in order to comply
NY Fire Safety Institute
NY Fire Safety Institute Presents the FDNY Coordinator of Fire Safety and Alarm Systems Homeless Shelters (Premise Related) Certificate of Fitness F-80 Definitions and Terminology Established 1995 Preparing
IR F-1 EMERGENCY VOICE/ALARM COMMUNICATION SYSTEMS
IR F-1 Disciplines: Fire/Life Safety History: Revised 10-01-15 Issued 06-23-15 PURPOSE: This Interpretation of Regulations (IR) is being issued by the Division of the State Architect (DSA) to clarify when
Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems
Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Appendix A Proposed amended Acceptable Solution for Warning Systems s in the grey boxes form part of the proposed
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM To be completed by the system inspector or tester at the time of the inspection or test. It shall be permitted to modify this form
Fire Alarm Systems Requirements by Occupancy Type
WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Fire Alarm Systems Requirements by Occupancy Type 2013 California Building
Module 5. Fire and Emergency Alarm System Part I- Basics
Module 5 Fire and Emergency Alarm System Part I- Basics 1 This module will describe: 1. Components and the arrangements of components in fire and emergency alarm systems. 2. How these systems work. 3.
NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.
NFPA 72 3.3.7.2 3.3.7.2 False Alarm. Activation or reporting of an alarm for which no such alarm condition, fire or emergency actually exists. Additionally, False Alarm is the willful and knowing initiating
FIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
ACOUSTICAL CONSIDERATIONS FOR EFFECTIVE EMERGENCY ALARM SYSTEMS IN AN INDUSTRIAL SETTING
ACOUSTICAL CONSIDERATIONS FOR EFFECTIVE EMERGENCY ALARM SYSTEMS IN AN INDUSTRIAL SETTING Dennis P. Driscoll, P.E. and David C. Byrne, CCC-A Associates in Acoustics, Inc. Evergreen, Colorado Telephone (303)
PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM
PARTICIPATION HOUSE 9 BUTTERNUT LANE, MARKHAM B 3 CASE STUDY RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO PARTICIPATION
MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES
MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES September 13, 2012 MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES WELCOME Exits Restrooms
AETNA FIRE ALARM SERVICE CO., INC.
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM To be completed by the system inspector or tester at the inspection or test. It shall be permitted to modify this form as needed
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
Bold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted
ONYX EXITPOINT TM THE SOUND OF SAFETY
ONYX EXITPOINT TM THE SOUND OF SAFETY In an emergency evacuation, people often rely on their senses - especially eyesight - and memory. But in a crisis, confusion can set in. Smoke, dust, debris or visual
USER INSTRUCTIONS CONTENTS
CONTENTS Full Set [1]...2 Part Set [2]...2 Night Set [3]...3 Unsetting...3 Unsetting after or during an alarm...3 Testing the system [5]...3 Isolating zones [6]...4 Reprogramming codes [8]...4 Chime facility
Fire Alarm Systems Permit Packet. City of Greer Fire Department
Fire Alarm Systems Permit Packet City of Greer Fire Department Updated July 2004 If you have any questions or comments regarding the information contained within; or of you need assistance interpreting
REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING APPLICATION PACKET
REGULATIONS for INSTALLATION, MAINTENANCE, and TESTING FIRE ALARM SYSTEMS APPLICATION PACKET CITY OF NAPERVILLE 400 S EAGLE STREET NAPERVILLE, Il 60540 PHONE: 630.420.6070 FAX: 630.420.6657 Fire Alarm
FIRE DETECTION AND ALARM
Scope Provide a fire alarm system, or expand the existing system, as required by Code, the requirements in the Special Instructions to Designers (SID) of the Design Guidelines, and/or as noted in the Program
Fire Alarm system Installation Guide
Fire Alarm system Installation Guide Fire Alarm System Categories Systems designed for Protection of Property only, fall into two classifications P1 or P2. but a manual system is also needed, then this
System-Connected Carbon Monoxide Detectors
A P P L I C A T I O N S G U I D E System-Connected Carbon Monoxide Detectors S Y S T E M S E N S O R System-Connected Carbon Monoxide Detectors Contents Introduction...2 Section 1: Standards That Apply...2
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
FIRE ALARM SYSTEM RECORD OF COMPLETION
FUNDAMENTALS OF FIRE ALARM SYSTEMS 72 33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat
SECTION 16721 FIRE ALARM AND DETECTION SYSTEM
1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions
Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007
Telluride Fire Protection District Fire Alarm Systems Policy Version 03/2007 FIRE ALARM SYSTEMS POLICY TELLURIDE FIRE PROTECTION DISTRICT TABLE OF CONTENTS FIRE ALARM PROTECTION POLICY PLAN REVIEW SUBMITTAL
Waking effectiveness of alarms (auditory, visual and tactile) for adults who are hard of hearing. D. Bruck 1 and I. Thomas 2
Waking effectiveness of alarms (auditory, visual and tactile) for adults who are hard of hearing D. Bruck 1 and I. Thomas 2 1 School of Psychology 2 Centre for Environmental Safety and Risk Engineering
FIRE ALARM SYSTEM RECORD OF COMPLETION
FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. 1. Protected Property Information Name of property: Description
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION
FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this
Smoke Alarms in U.S. Home Fires
Smoke Alarms in U.S. Home Fires September 2015 Marty Ahrens September 2015 National Fire Protection Association Abstract Smoke alarms provide a critical early warning of fire, allowing additional time
Guide to Massachusetts Smoke & Carbon Monoxide Requirements
Guide to Massachusetts Smoke & Carbon Monoxide Requirements When Selling a One- or Two-Family Residence DEPARTMENT OF FIRE SERVICES Stephen D. Coan State Fire Marshal M.G.L. c 148 s. 26F - The Law Massachusetts
Inspections must be conducted every three years in order to maintain an "approved" status on the City Of Bozeman Safe Rental Unit List.
The purpose of the program is to ensure the health, safety, and welfare of those living in or near rental housing through the participation of owners, tenants, the city, and the community. This program
Smoke Alarms. New smoke alarm requirements for existing buildings from 1 May 2006. Introduction. Advisory note March 2006
New smoke alarm requirements for existing buildings from 1 May 2006 Advisory note March 2006 Introduction To enhance safety and minimise loss-of-life in building fires, the NSW Parliament, in July last
FIRE ALARM SYSTEMS INFORMATION PACKET
FIRE ALARM SYSTEMS INFORMATION PACKET Exeter Township Fire Department Office of the Fire Official 2010 1 TABLE OF CONTENTS PURPOSE, SCOPE, DEFINITIONS...3 GUIDELINES...3 I. INTRODUCTION...3 A. APPLICABLE
Agenda. Agenda (continued) Fundamentals of Fire Alarm Systems
Fundamentals of Fire Alarm Systems Sponsored by UL SFPE Austin/San Antonio Chapter San Marcos, Texas 7 January 2015 Agenda Introduction and Administration Historical Context of Today s NFPA 72 Fire Alarm
www.firesafety.vermont.gov
VERMONT DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE SAFETY OFFICE OF THE STATE FIRE MARSHAL, STATE FIRE ACADEMY and THE STATE HAZ-MAT TEAM www.firesafety.vermont.gov EFFECTIVE DATE ~ November 5, 2012
SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS
CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL
BS5839 Part 1:2002 Overview
BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire
Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.
Page 1 of 17 Page 2 of 17 Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology. CODE PARAGRAPH WITH SUGGESTED CHANGES: 6.4.6.1.2 Residents should be rated as response probable
Practice Note 2006-27
Practice Note Self-Contained smoke alarms to existing buildings This updates the previous Practice Note 2005-27 issued May 2005. Reference to the BCA in this Practice Note means Volume One and Volume Two
Danville, IN Code of Ordinances CHAPTER 90: ALARM SYSTEMS, SMOKE DETECTORS AND THE LIKE. Alarm Systems. Smoke Detectors. Key and Data Storage Boxes
Danville, IN Code of Ordinances CHAPTER 90: ALARM SYSTEMS, SMOKE DETECTORS AND THE LIKE Section Alarm Systems 90.01 Purpose 90.02 Definitions 90.03 Exemptions 90.04 Registration 90.05 Violations; fines
I.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL 1951 Smith Street, North Providence, RI 02911 Telephone: (401) 383-7717 Fax: (401) 383-8879 John E. Chartier, EFO, CFI State Fire Marshal Rhode Island State
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us
Faraday Intelligent Fire Detection Systems
Faraday Intelligent Fire Detection Systems Faster detection means better protection for buildings and the people in them. Greater safety and value for new and retrofit applications The right fit Fire safety
Fire Alarm System Plans Review Checklist Property location Date of Review
Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include
NFPA 101 2012 SELECT SIGNIFICANT CHANGES
NFPA 101 2012 SELECT SIGNIFICANT CHANGES William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com [email protected] Expertly Engineering Safety From Fire INTRODUCTION NFPA 101 is
1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.
GENERAL: 1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri. 2. Fire alarm systems are Life Safety Systems
NATIONAL FIRE ALARM AND SIGNALING CODE
GAP.11.1.1.0 A Publication of Global Asset Protection Services LLC NATIONAL FIRE ALARM AND SIGNALING CODE INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection
GEORGIA DEPARTMENT OF COMMUNITY AFFAIRS (DCA) STATE CODES ADVISORY COMMITTEE (SCAC) CARBON MONOXIDE DETECTORS FOR SCHOOLS TASK FORCE
Important Discussion Points about Carbon Monoxide and Schools 1. What happened to make carbon monoxide in schools an important issue for the State? On December 3, 2012, approximately 40 students and staff
TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS
TESTING, INSPECTION, AND MAINTENANCE FREQUENCIES FOR FIRE DETECTION AND ALARM SYSTEMS The following information regarding testing frequencies for fire detection and alarm systems. All of the following
What you need to know about. Smoke alarms for residential buildings
What you need to know about Smoke alarms for residential buildings Are s compulsory? Smoke alarms are compulsory and must be installed in residential buildings on or near the ceiling of every storey. What
FIRE ALARM PLAN REVIEW. Office of the State Fire Marshal Massachusetts Department of Fire Services December 2009
FIRE ALARM PLAN REVIEW Office of the State Fire Marshal Massachusetts December 2009 SURPRISE QUIZ 1. A fire alarm system is required to be installed by the MSBC, what edition of NFPA 72 do you use? 2.
SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS
SUBCHAPTER F. SMOKE ALARMS AND FIRE EXTINGUISHERS Sec. 92.251. DEFINITIONS. In this subchapter: (1) "Bedroom" means a room designed with the intent that it be used for sleeping purposes. (2) "Dwelling
Smoke & Carbon Monoxide
A Guide to the Massachusetts Smoke & Carbon Monoxide Requirements when Selling a Oneor Two-Family Residence FIRE SERVICES Department of Fire Services www.mass.gov/dfs M.G.L. C 148 S. 26F - THE LAW Massachusetts
CHAPTER 9 FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL 901.1 Scope. Provisions of this chapter shall govern the application, design, installation, testing and maintenance of automatic sprinklers, standpipes
I.S. 3218 :2013 Fire Detection & Alarm Systems
I.S. 3218 :2013 Fire Detection & Alarm Systems Overview of significant changes 26 th March 2014 FPS Ltd Today s Programme Commencement Transition Competence & Qualifications System Certification System
USER S MANUAL. SMDC-16 Digital Control Communicator and SMPC-32 Personal Control
SMDC-16 USER S MANUAL SMDC-16 Digital Control Communicator and SMPC-32 Personal Control Table of Contents General Descriptions Page Description of Your Alarm System 3 Description of Keypads 3 Keypad Maintenance