ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec www.startwithunitec.com



Similar documents
Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Wash Select II to WashPay Integration Field Retrofit Installation Guide

Networkfleet 3500 Product Line Installation Guide

PCS300 Universal IP Reporting Module V1.0

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

HP UPS R1500 Generation 3

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

How To Wire Wireline Cable To A Cell Phone (New Zealand)

Replacing a Vantage Vue Transmitter

2M IR Mini Dome Quick Installation Guide

Control Box Wiring For PRSstandard Tool

CRYPTOPAY QUICK START GUIDE

Auto Sentry-eXP Maintenance

TS93 EMR T/PT/TDE. Surface applied door closer

2003/2004/2005 TOYOTA COROLLA

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SmartCard On-Board Reader (# 8105) SmartCard Desktop Reader (# 8108) SmartCards, Pack of 10 (# 8112) Starter Interrupter Kit (# 8116)

UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Installation Instructions

Remote Access System Installation

GENUINE PARTS INSTALLATION INSTRUCTIONS

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

PRO 5000 CPE 1D Quick Installation Guide

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

EZ-Steer Assisted Steering System

Post Mount Light Installation*

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Installing Your 960 or 980 Server into a Rackmount Cabinet

Anthro Tablet Charging Cabinets

DC Series Digital Conversion Alarm Operator s Manual

Before installation it is important to know what parts you have and what the capabilities of these parts are.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

430 Power/Electronics Replacement

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

LIEBERT VNSA Installation Sheet

ELECTRONICS G H I J K L M

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

Installation Instructions

INSTRUCTIONS: LocknCharge Laptop Carts

Installing RNS-E SAT NAV for Audi A4

Rack installation instructions

MGB Chrome Bumper Conversion

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

All-Season Sunroom Sliding Glass Door Installation Instructions

To Purchase This Item, Visit BMI Gaming

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

GSM-EXT Cable Assembly Installation Guide

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

Home Signal Distribution Kit for Satellite TV Plus SIRIUS

4.3-inch Back-Up Camera

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Installation Instructions

USER MANUAL V5.0 ST100

AMS 120. EFT Guest Card Terminal & Refund unit

GPS AutoSteer System Installation Manual

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

Home Signal Distribution Kit for Cable TV Plus SIRIUS

Cooktop Low-Profile Ventilation Hoods

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

Wiper Motor Marinco 2.5. Installation Instructions

Building A Computer: A Beginners Guide

Installation Instructions

AZEK Rail Install Guide

ATS Overhead Table Shelf System INSTRUCTION MANUAL

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

ELECTRONIC LOGGING DEVICE. User Manual

FTC DIY Mountain Build Guide

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

MODELS 7007 Gorilla Cycle Alarm 7017 Gorilla Cycle Alarm with 2-way pager system way pager system

Installation Instructions For Slider Casement Air Conditioners

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

AR-721U/721K/661U User s Guide

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

INSTALLATION MANUAL. Installation Instructions

PROXIMITY CARD READERS C-10, C-20, C60, C70

WARNING CANADIAN D.O.C. WARNING

ALARM SYSTEM INSTALLATION GUIDE

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE

Accessories: 6-pin to 9-pin adapter cable.

Traditional Sonar and DSI Sonar Installation

Transcription:

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start Unitec www.startwithunitec.com

Proprietary Information and Materials of Unitec, Inc. Such proprietary information and materials may not be disclosed to third parties without the prior written consent of Unitec Inc. 2015 Unitec, Inc. All rights reserved. Document Number: RFID1001 ii

Table of Contents Introduction... 1 Software Requirements... 1 Site Planning... 1 Parts Checklist... 1 Installation Procedures... 2 Install the Mounting Pole (Optional)... 2 Install the Reader... 4 Site Installation... 6 Connector Wiring... 8 Mount RFID Board and Connect Cables... 9 Portal TI Installation... 9 Sentinel and C-Start Installation... 12 RFID Tags... 14 Program the Unitec Entry Unit... 14 Troubleshooting... 15 Document Number: RFID1001 iii

Table of Figures Figure 1. RFID Mounting Post... 2 Figure 2. RFID Post Flange... 3 Figure 3. AWID Reader Dimensions... 4 Figure 4. Reader... 4 Figure 5. Pole Mounting Bracket... 5 Figure 6. RFID Reader Installation - Front View... 6 Figure 7. RFID Reader Installation - Top View... 7 Figure 8. Wired Connector... 8 Figure 9. RFID Board Location in Portal with Coin/Bill Dispensing... 9 Figure 10. RFID Board Location in Cashless Portal... 9 Figure 11. RFID Board Connections for Portal... 11 Figure 12. RFID Board Location in Sentinel... 12 Figure 13. RFID Board Connections for Sentinel and C-Start... 13 Figure 14. Sample RFID Tag... 14 Figure 15. RFID Troubleshooting Screen... 15 Figure 16. RFID Settings Screen... 16 Document Number: RFID1001 iv

Introduction The ReachFree ID product is a house account application designed to build car wash volume and increase throughput with secure, subscription-based wash accounts. The RFID reader reads the RFID tag that is adhered to the account holder s windshield. If the account is valid, the Unitec entry unit will approve the transaction without any interaction from the account holder and will allow the vehicle to proceed past the entry system and into the tunnel or in-bay automatic. Software Requirements In order for the ReachFree ID system to function properly, the Unitec entry unit must be updated to the most recent version of software. Site Planning If this is a new installation, a conduit will need to be run from the Unitec entry unit to the mounting surface for the reader. The reader may be mounted on any material including metal, but there must be open space in front of the reader and to its sides. There must be no material interfering with the reader s surveillance zone between the reader and the tags location. If using the optional mounting pole, the reader should be mounted beside the far side of the Unitec entry unit (with the flange flush against the base, as shown in Figure 5) because the proximity sensor on the unit door can be setup to activate the reader. The reader should be mounted on a pole 7 feet above the vehicle lane. Parts Checklist Prior to retrofitting an existing Unitec entry unit, verify that you have all parts required: AWID RFID Reader with cable (SA2135) Reader pole-mounting bracket (OM1683) Power Supply (PS2018) 30 ft data cable (CA2179) RFID Board (OM1528) mounted on bracket (MF1583) with 2 6-32 nuts I2C Cable 50 RFID tags (OM1672) (Please note: tag refills come in groups of 50) 8ft Mounting Pole (MF1589) (Optional) 3/8 concrete bolts (Optional) Drill with concrete bit (not included) Document Number: RFID1001 1

Installation Procedures Install the Mounting Pole (Optional) The RFID kit comes with an 8 foot mounting post with a mounting flange at the base, as an option. It s designed to accommodate both surface-mounted above ground conduit for existing installations and underground conduit for new construction. For surface run conduit, there s a threaded boss welded to the post on the bottom flange. It accommodates a ½ conduit fitting to run liquid-tight conduit to the post. The conduit is then secured by screwing the conduit fitting into the boss. For underground conduit, the installer should run the conduit up the center of the post. There is a hole near the top of the post where the cable will exit to connect with the RF reader. Figure 1. RFID Mounting Post Document Number: RFID1001 2

To mount the post, the installer will need to drill (4) holes and use concrete anchor bolts to secure the flange to the concrete, as shown below. The flange should be flush to the side of the entry unit, as shown in Figure 5. Figure 2. RFID Post Flange Document Number: RFID1001 3

Install the Reader Note: Keep the reader assembled. Do not remove the aluminum plate behind the reader. Do not remove the plastic cover of the reader. Do not tighten or loosen the screws through the cover. Figure 3. AWID Reader Dimensions Figure 4. Reader Document Number: RFID1001 4

Figure 5. Pole Mounting Bracket 1. Attach the mounting assembly to the reader s metal plate using 1/4-20 screws, if needed for your installation. 2. If you are mounting the reader to a pole, leave the mounting assembly fully assembled and use the supplied bracket clamp to secure the reader to the pole approximately 7 feet above the lane. Note: If you are mounting the reader on to something other than a pole, you will need to order another style of mount. Document Number: RFID1001 5

Site Installation Figure 6. RFID Reader Installation - Front View 3. Aim the reader so that center front face of the reader points toward a spot on the vehicle lane approximately 18 from the middle front of the entry unit. This usually requires that the reader be adjustable downward about 45 to 90 degrees ( tilt ), and slightly toward the approaching vehicles ( pan ). Document Number: RFID1001 6

Figure 7. RFID Reader Installation - Top View Document Number: RFID1001 7

Connector Wiring Figure 8. Wired Connector Document Number: RFID1001 8

Mount RFID Board and Connect Cables Portal TI Installation If installing the board inside a Portal with coin or bill dispensing, the RFID board mounts to the side of the bill dispenser/coin hopper cage inside the entry unit. Figure 9. RFID Board Location in Portal with Coin/Bill Dispensing If installing the board inside a cashless Portal, the RFID board mounts to the top back wall of the unit to the left of the power supply tower. Figure 10. RFID Board Location in Cashless Portal Document Number: RFID1001 9

1. Run the data cable down thru the unit s conduit and up to the mounted reader. 2. Plug the female end of the in-line connector on the 30 data cable into the male end of the in-line connector on the reader. To ensure a tight, water-proof connection, fit the two ends together, press firmly and turn the ends to lock them together. 3. Connect the other end of the data cable with the 6-pin Phoenix connector to the J2 connector on the RFID board 4. Plug the power supply into the J1 power connector on the RFID board and the power supply cord into an outlet on the power supply panel at the back of the unit. 5. Connect the 4-pin I2C cable to the J3 4-pin connector on the RFID board. Connect the other 4-pin connector to the CN3 connector at the bottom of the carrier board on the right wall of the unit. Document Number: RFID1001 10

Figure 11. RFID Board Connections for Portal Document Number: RFID1001 11

Sentinel and C-Start Installation If installing the board inside a Sentinel or C-Start unit, the RFID board mounts to the right inside wall of the electronics side of the unit. Note: The RFID board should be mounted upside down on the mounting plate so that the diagnostic LEDs are facing the door of the unit. Figure 12. RFID Board Location in Sentinel 1. Run the data cable down thru the unit s conduit and up to the mounted reader. 2. Plug the female end of the in-line connector on the 30 data cable into the male end of the in-line connector on the reader. To ensure a tight, water-proof connection, fit the two ends together, press firmly and turn the ends to lock them together. 3. Connect the other end of the data cable with the 6-pin Phoenix connector to the J2 connector on the RFID board 4. Plug the power supply into the J1 power connector on the RFID board and the power supply cord into an outlet on the power supply panel at the back of the unit. 5. Connect the 4-pin I2C cable to the J3 4-pin connector on the RFID board. Connect the other 5-pin end to a 5-pin connector on the CPU module on the left side of the case. Document Number: RFID1001 12

Figure 13. RFID Board Connections for Sentinel and C-Start Document Number: RFID1001 13

RFID Tags Figure 14. Sample RFID Tag The ReachFree ID vehicle tag should be applied to the INSIDE bottom or top corner of the windshield on the driver s side, depending on the height of the vehicle, so that the tag is in approximately the same place on every vehicle. For example, if the vehicle is a taller SVU, apply the tag to the bottom of the windshield. If the vehicle is a smaller sports car, apply the tag to the top corner of the windshield. Make sure the windshield is clean before adhering the tag to the glass. Program the Unitec Entry Unit The ReachFree ID system is based off a subscription-based house account. You will need to set up a house account program and account for each vehicle tag. For more information, see the Sierra Management Application Programming Manual, which is available on our website at http://www.startwithunitec.com/. The RFID reader s default setting is set to Always On. If you wish to change it so that the reader is triggered to turn on by the proximity sensor in the entry unit, you must configure the RFID reader in the Device Profiles tab. Document Number: RFID1001 14

Troubleshooting Figure 15. RFID Troubleshooting Screen Login to Maintenance Mode>Test Hardware>RFID Reader to make sure the ReachFree ID system is reading the tags properly. Once the vehicle tag is detected by the reader, the 8-digit code will be displayed in the text box on the screen. As long as the RF tag remains in range of the reader, the entry unit will beep once per second. You can determine the area the RF Reader can read tags by moving the tag around and listening for the beeps. As long as the unit is beeping once per second, the RF tag is in-range. Document Number: RFID1001 15

To adjust the power or threshold (read rate) of the reader, press Adjust Antenna. Figure 16. RFID Settings Screen The power level and threshold may be adjusted from 1-7 with 7 being the highest. The threshold (or read rate) reads at a multiple of 6 per second. For example, if the threshold is set to 4, the read rate is 24 tag reads per second. These settings are also available on the pots on the RFID board. NOTE: The software settings override the pot setting on the board. The top pot on the Portal RFID board (bottom pot on Sentinel) controls the power output on the reader.. If you need to adjust the power for the reader on the board, insert a small flat head screwdriver in top pot in the slot facing out toward the door of the unit and turn it counter-clockwise to reduce the power output. The power levels range from 1 to 7, with 7 being the highest. Since the pot and power level numbers are very small, the top 3 LEDS will also light up in the corresponding sequence listed in the following table: Document Number: RFID1001 16

LEDs Power Level No LEDs lit 0 1 Green LED middle LED) 1 1 Yellow LED 2 1 Green LED + 1 Yellow LED 3 1 Red LED 4 1 Green LED + 1 Red LED 5 1 Yellow LED + 1 Red LED 6 1 Green LED + 1 Yellow LED + 1 Red LED 7 The bottom pot on the Portal RFID board (top pot on the Sentinel) controls the threshold (rate of tag reads per second). If you need to adjust the threshold for the reader, insert a small flat head screwdriver in pot in the slot facing out toward the door of the unit and turn it to adjust the threshold. The levels range from 1 to 7, with 7 being the highest. Since the pot and power level numbers are very small, the top 3 LEDS will also light up in the corresponding sequence listed in the table below: LEDs Read Rate per Second (x6) No LEDs lit 0 1 Green LED middle LED) 1 1 Yellow LED 2 1 Green LED + 1 Yellow LED 3 1 Red LED 4 1 Green LED + 1 Red LED 5 1 Yellow LED + 1 Red LED 6 1 Green LED + 1 Yellow LED + 1 Red LED 7 Document Number: RFID1001 17

LEDS The RFID board has 5 LEDs that indicate whether or not the RFID system is working. The table below defines each LED and its function. LED Label Color Light Status Description LED 1 Serial Red LED 2 I2C Yellow Blinks during data transfer Blinks during data transfer LED 3 Ant On Green Solid LED 4 Status Green Blinking Indicates when the RF Reader sends data to the RFID board. Most of the time this will be when the RF Reader senses a RF tag. Indicates when the RFID board sends and receives data to and from the entry unit Indicates when the reader is enabled. If the reader is enabled by the proximity sensor, then this LED will be OFF most of the time. If the reader is always enabled then this LED will be constantly lit. Blinks once per second to show that the RFID board is alive LED 5 Power Green Solid Indicates power to the board Tips and Suggestions The ReachFree ID reader uses the 900 MHz frequency which can cause interference with other electronic devices that use the 900 MHz frequency range. Unitec strongly suggests you observe the following warnings: Stay away from UHF communications devices. Avoid arc lighting fixtures by 3 or 4 feet. Keep neighboring long-range readers on parallel lanes at least 12 feet apart, with their surveillance zones parallel to each other. Do not have identical readers facing each other (but back-to-back is OK). Document Number: RFID1001 18