MegaRAID LSIiBBU09 Intelligent Battery Backup Unit



Similar documents
MegaRAID LSIiBBU08 Intelligent Battery Backup Unit. Quick Installation Guide

MegaRAID SAS i and SAS i RAID Controllers

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module

MegaRAID Advanced Software Options Electronic License Activation. User Guide

HP UPS R1500 Generation 3

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Small form factor bay converter and hard drive installation

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

StorTrends 3400 Hardware Guide for Onsite Support

Intel NUC Kit DC3217IYE User Guide. Intel NUC Kit DC3217IYE

Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S

Upgrading and Servicing Guide

SCSI Card 2930CU. Installation Guide

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Processor Cage Fans, Front and Rear Replacement Instructions

PA500II Enterprise Mobile Computer

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

3-Port FireWire 800/400 PCI Host Card

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

HP ProLiant DL165 G7 Server. Installation Instructions

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Wall-Mounting your HP computer. User Guide

Inspiron 15. Service Manual Series

Power Supply Guide Version 1.0 for D-Show

Front Panel Board Cable Replacement Instructions

MSM Software Feature Difference Between the MR Controller and the IR Controller

Chapter 2 Installation

Set Up Your MXI -Express x1 System

Intel RAID Controllers

Memory Modules User Guide

AUPS-C20. User Manual MODEL: VESA Mount Intelligent UPS Module, 9 V ~ 28 V DC Input, 100 W Power Output, Network Remote Management Support

Serial ATA PCI Quick Installation Guide

FUSION R400 RAID USB 3.0

Identity Theft. Credit Card Fraud. Hackers. Terrorists. It s scary out there.

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

AUPS Series. User Manual MODEL: VESA Mount Intelligent UPS Module 12 V DC Input or 9 V ~ 36 V DC Input Network Remote Management Support

DataCenter Gb/s SATA Host Adapter User Manual

Set Up Your MXI -Express x4 System

TS500-E5. Configuration Guide

CalDigit SuperSpeed PCI Express Card

UPGRADING AND SERVICING GUIDE

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

T7 PCI-EPP Conversion

RAID EzAssist Configuration Utility Quick Configuration Guide

The Revival of Direct Attached Storage for Oracle Databases

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

2013 VTech Printed in China US

BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)

i-ram (GC-RAMDISK) User's Manual Copyright Notice Rev MD-RAMDISK-102R

USB Port PCI Express Card

SATA II-150 PCI Quick Installation Guide

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

WIRELESS STATUS MONITOR

Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

HP SATA/SAS hard drive and Solid State Drive installation

TESLA C2050/2070 COMPUTING PROCESSOR INSTALLATION GUIDE

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

Replacing a Dual Fan Unit on the GQAM Modulator

Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures

DP Hi-Speed USB 4-Port PCIe Quick Installation Guide

PAR Tablet 10 Quick Start Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

SMART Board 8070i-SMP and 8070i

Changing the SIM in a BANDIT Product s GSM Card

How To Install A Power Supply (Uplast) With A Battery Pack

Optimized dual-use server and high-end workstation performance

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

Serial ATA RAID PCI Card

6Gb/s MegaRAID SAS RAID Controllers

Table Of Contents

USB Port PCI Express Card

PCI/PXI ETHERNET ADAPTERS

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

430 Power/Electronics Replacement

NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)

Dell Inspiron 660s Owner s Manual

HP ProLiant Moonshot Cartridge User and Maintenance Guide

PCI-to-SATA RAID Adapter AEC-6890M. User s Manual Version:1.0

Replacing the Gateway M320 Keyboard

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Cooktop Low-Profile Ventilation Hoods

2 Bay FireWire 800/400/USB RAID Solution RAID 0, RAID 1, & JBOD. User Manual

Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card

DD160 and DD620 Hardware Overview

Old Company Name in Catalogs and Other Documents

Service Guide. Gateway M275

SMART Board 8055i and 8055i-SMP

Hard Disk Drive (HDD)

aseries A13B Mini Bullet Camera User Manual

Installing Your 960 or 980 Server into a Rackmount Cabinet

MegaRAID 6Gb/s SAS RAID Controllers

Installing EDS III or EDS IV Network Support for Microsoft Windows 95 or 98 Part Number Rev. D

Wash Select II to WashPay Integration Field Retrofit Installation Guide

FASTA-2e 2 Port PCI-Express SATA 3G Card. User Manual

Transcription:

MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide 49760-00, Revision A January 2011 49760-00A

Revision History Version and Date 49760-00 Rev. A, January 2011 Initial release of the document. Description of Changes LSI, the LSI Design, and the MegaRAID logo are trademarks or registered trademarks of LSI Corporation or its subsidiaries. All other brand and product names may be trademarks of their respective companies. LSI Corporation reserves the right to make changes to the product(s) or information disclosed herein at any time without notice. LSI Corporation does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by LSI Corporation; nor does the purchase, lease, or use of a product or service from LSI Corporation convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Corporation or of third parties. This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of LSI Corporation. Corporate Headquarters Milpitas, CA 800-372-2447 Document Number: 49760-00, Rev. A Copyright 2011 LSI Corporation All Rights Reserved Website www.lsi.com

Product Overview Quick Installation Guide MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Thank you for purchasing the LSI MegaRAID LSIiBBU09 intelligent battery backup unit (ibbu). Before you install and connect the LSIiBBU09 unit, please take a few minutes to read this quick installation guide. This guide explains how to connect the LSIiBBU09 unit remotely to your MegaRAID SAS RAID controller. If you need more information about any topic covered in this guide, refer to the related documents on your MegaRAID Universal Software Suite CD. Product Overview LSI provides a family of MegaRAID ibbus for use with its high-performance MegaRAID RAID controllers. The LSI MegaRAID ibbus provide an inexpensive alternative to using an uninterruptible power supply (UPS) and a second level of fault tolerance when used with a UPS. The LSI MegaRAID LSIiBBU09 product is an ibbu based on Lithium ion (LiON) battery cell technology. The LSIiBBU09 unit protects the integrity of the cached data on a MegaRAID RAID controller for up to 48 hours (depending on the derated retention time selected) in case of a complete AC power failure or a brief power outage. The LSIiBBU09 unit connects remotely to the TMM02 transportable memory module on the following SAS RAID controllers: MegaRAID SAS 9265-8i RAID controller MegaRAID SAS 9285-8e RAID controller You have two ways to connect the remote LSIiBBU09 unit by cable to a TMM02 transportable memory module: Connect the LSIiBBU09 unit by cable to the TMM02 module on the RAID controller and then mount the LSIiBBU09 unit on the system chassis (see Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a RAID for the procedures). Connect the LSIiBBU09 unit on a remote mounting board to the TMM02 module on the RAID controller (see Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID for the procedures). CAUTION: The battery used in this device might present a fire or chemical burn hazard if mistreated. Do not disassemble, heat above 100 C (212 F) or incinerate. Dispose of used battery properly. Keep away from children. January 2011 Page 3

Top View and Bottom View of the LSIiBBU09 Unit Top View and Bottom View of the LSIiBBU09 Unit The following figure shows the top view and the bottom view of the LSIiBBU09 unit. The top view is the side that you can see after you install the LSIiBBU09 unit on the system chassis or when the unit is installed on a remote mounting board. LSI CORP. 2010 ALL RIGHTS RESERVED Pb e1 ASSEMBLED RoHS AsRPCB IN CHINA E248037 94V0! Model: BAT1S1P-A BBU P/N: L4-25407-00 L3-25407-00A BBU S/N: SAYWWSSSSSss Contains: Sony US454261A8T Cell Rechargeable Li-Polymer Battery Pack Rating: 3.7V; 1.59 Ah; 5.9Wh Finished in China WARNING: The battery used in this device may present a risk of fire or chemical burn if mistreated. DO NOT disassemble, heat above 60C, crush or puncture, short circuit external contacts, or dispose of in fire or water. MH29577 Li-ion Li Ion Top View 85083-00 1 2 Bottom View Figure 1: Top View and Bottom View of the LSIiBBU09 Unit 1. Remote Cable Connector 2. Board-to-Board Connector NOTE: Record your controller serial number in a safe location in case you need to contact LSI. Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a RAID The procedures in this section show how to connect a remote LSIiBBU09 unit on the system chassis to the MegaRAID SAS 9265-8i RAID controller. You can connect the LSIiBBU09 unit in the same way to the MegaRAID SAS 9285-8e RAID controller. To connect a remote LSIiBBU09 unit to your RAID controller, perform the following tasks in order: 1. Removing the RAID from the Computer 2. Connecting the Cable Between the TMM02 Module on the RAID and the Remote LSIiBBU09 Unit 3. Reinstalling the RAID in the Computer Page 4 January 2011

Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a RAID NOTE: Because server and workstation chassis vary from vendor to vendor, no standard mounting option exists that is compatible with the various system configurations. The LSIiBBU09 battery kit, in combination with the Remote Battery Kit, includes the battery, daughtercard, cable, and standoff. This combination enables authorized resellers and chassis manufacturers to customize the location of the remote battery to provide the most flexibility within various environments. Removing the RAID from the Computer Connecting the Cable Between the TMM02 Module on the RAID and the Remote LSIiBBU09 Unit Follow these steps to remove the RAID controller from the computer. 1. Turn off the power, and unplug the power cords. 2. Ground yourself, and make sure that the system is grounded. 3. Remove the cover from the computer, according to the instructions in the system user s manual, to allow access to the controller. 4. Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and carefully remove the controller from the slot. 5. Place the controller on a flat, clean, static-free surface, and continue with the next procedure. Follow these steps to connect the cable between the TMM02 module on the RAID controller and the LSIiBBU09 unit. 1. Mount the LSIiBBU09 unit to the chassis of your computer based on the location and the type of mounting option. 2. With the controller on a flat, clean, static-free surface, ground yourself, and make sure that the system is grounded. 3. Remove the cable included in the Remote Battery Kit (sold separately). 4. Insert one end of the cable into the 20-pin cable connector on the LSIiBBU09 unit and the other end into the 20-pin J1L1 cable connector on the TMM02 module, as shown in Figure 2. Align the black triangles on the connectors to make sure that the connectors are connected properly. NOTE: The cable connectors are polarized and can be inserted into the cable connectors on the TMM02 module and the LSIiBBU09 unit only if the rails on the cable connectors align with the slots on the other connectors. Do not force the cable into the 20-pin connectors. The cable end inserts into the connector with minimal resistance. January 2011 Page 5

Contains:! Li-ion Connecting a Remote LSIiBBU09 Unit on the System Chassis to a TMM02 Module on a RAID LSI CORP. 2010 ALL RIGHTS RESERVED Pb e1 ASSEMBLED RoHS AsRPCB IN CHINA E248037 94V0 Model: BAT1S1P-A BBU P/N: L4-25407-00 L3-25407-00A BBU S/N: SAYWWSSSSSss WARNING: The battery used in this device may present a risk of fire or chemical burn if mistreated. DO NOT disassemble, heat above 60C, crush or puncture, short circuit external contacts, or dispose of in fire or water. Sony US454261A8T Ce l Rechargeable Li-Polymer Battery Pack Rating: 3.7V; 1.59 Ah; 5.9Wh Finished in China MH29577 Li Ion 85083-01 Figure 2: Connecting the LSIiBBU09 Unit on the System Chassis to the TMM02 Module on the RAID Reinstalling the RAID in the Computer Follow these steps to reinstall the RAID controller in the computer. 1. With the power to the chassis still turned off and the power cords unplugged, make sure that the chassis is grounded and has no AC power. 2. Insert the RAID controller in a PCI Express slot on the motherboard, as shown in Figure 3. NOTE: Some PCI Express slots support only PCI Express graphics cards; if a RAID controller is installed in one of these slots, the controller does not function. Refer to your computer documentation for information about the PCI Express slot. 3. Press down gently, but firmly, to seat the controller correctly in the slot. Page 6 January 2011

Contains:! Li-ion Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID Screw Press Here LSI CORP. 2010 ALL RIGHTS RESERVED Pb e1 ASSEMBLED RoHS AsRPCB IN CHINA E248037 94V0 Model: BAT1S1P-A BBU P/N: L4-25407-00 L3-25407-00A BBU S/N: SAYWWSSSSSss WARNING: The battery used in this device may present a risk of fire or chemical burn if mistreated. DO NOT disassemble, heat above 60C, crush or puncture, short circuit external contacts, or dispose of in fire or water. Sony US454261A8T Ce l Rechargeable Li-Polymer Battery Pack Rating: 3.7V; 1.59 Ah; 5.9Wh Finished in China MH29577 Li Ion Press Here 85083-02 PCI Socket Edge of Motherboard Figure 3: Reinstalling the RAID 4. Secure the controller to the computer chassis with the bracket screw. 5. Reinstall the computer cover, and reattach the power cords. 6. Turn on the power to the computer. Refer to the MegaRAID SAS Software User Guide for information about running the RAID configuration utility and installing the software drivers. Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID This section describes how to connect the LSIiBBU09 unit on the remote mounting board to your MegaRAID SAS RAID controller. A cable connects the remote LSIiBBU09 unit on the remote mounting board to the TMM02 module on the RAID controller. The procedures in this section show how to connect the LSIiBBU09 unit on the remote mounting board to the MegaRAID SAS 9265-8i RAID controller. You can connect the LSIiBBU09 unit on the remote mounting board to the MegaRAID SAS 9285-8e RAID controller in the same way. To connect a LSIiBBU09 unit on a remote mounting board to your RAID controller, perform the following tasks in order: January 2011 Page 7

Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID 1. Removing the RAID from the Computer 2. Connecting the Cable Between the TMM02 Module on the RAID and the LSIiBBU09 Unit on the Remote Mounting Board 3. Reinstalling the RAID in the Computer 4. Installing the Remote Mounting Board in the Computer Removing the RAID from the Computer Connecting the Cable Between the TMM02 Module on the RAID and the LSIiBBU09 Unit on the Remote Mounting Board Follow these steps to remove the RAID controller from the computer. 1. Turn off the power, and unplug the power cords. 2. Ground yourself, and make sure that the system is grounded. 3. Remove the cover from the computer, according to the instructions in the system user s manual, to allow access to the controller. 4. Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and carefully remove the controller from the slot. 5. Place the controller on a flat, clean, static-free surface, and continue with the next procedure. Follow these steps to connect the cable between the TMM02 module on the RAID controller and the LSIiBBU09 unit on the remote mounting board. 1. With the controller on a flat, clean, static-free surface, ground yourself, and make sure that the system is grounded. 1. Remove the cable included in the Remote Battery Kit (sold separately). 2. Insert one end of the cable into the 20-pin cable connector on the LSIiBBU09 unit on the remote mounting board and the other end into the 20-pin J1L1 cable connector on the TMM02 module, as shown in Figure 4. Align the black triangles on the connectors to make sure that the connectors are connected properly. NOTE: The cable connectors are polarized and can be inserted into the cable connectors on the TMM02 module and the LSIiBBU09 unit only if the rails on the cable connectors align with the slots on the other connectors. Do not force the cable into the 20-pin connectors. The cable end inserts into the connector with minimal resistance. Page 8 January 2011

Contains:! Li-ion Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID Li Ion MH29577 WARNING: The battery used in this device may present a risk of fire or chemical burn if mistreated. DO NOT disassemble, heat above 60C, crush or puncture, short circuit external contacts, or dispose of in fire or water. Sony US454261A8T Ce l Rechargeable Li-Polymer Battery Pack Rating: 3.7V; 1.59 Ah; 5.9Wh Finished in China BBU S/N: SAYWWSSSSSss Model: BAT1S1P-A BBU P/N: L4-25407-00 L3-25407-00A LSI CORP. 2010 ALL RIGHTS RESERVED Pb e1 ASSEMBLED IN CHINA RoHS AsRPCB E248037 94V0 85083-04 Figure 4: Connecting the LSIiBBU09 Unit on the Remote Mounting Board to the TMM02 Module on the RAID Reinstalling the RAID in the Computer Follow these steps to install the RAID controller in the computer. 1. With the power to the chassis still turned off and the power cords unplugged, make sure that the chassis is grounded and has no AC power. 2. Insert the RAID controller in a PCI Express slot on the motherboard, as shown in Figure 5. NOTE: Some PCI Express slots support only PCI Express graphics cards; if a RAID controller is installed in one of these slots, the controller does not function. Refer to your computer documentation for information about the PCI Express slot. 3. Press down gently, but firmly, to seat the controller correctly in the slot. January 2011 Page 9

Contains:! Connecting a LSIiBBU09 Unit on a Remote Mounting Board to a TMM02 Module on a RAID Screw Press Here Li Ion Li-ion MH29577 disassemble, heat above 60C, crush or puncture, short circuit external contacts, or dispose of in fire or water. Rechargeable Li-Polymer Battery Pack Rating: 3.7V; 1.59 Ah; 5.9Wh Finished in China Sony US454261A8T Ce l WARNING: The battery used in this device may present a risk of fire or chemical burn if mistreated. DO NOT Press Here BBU S/N: SAYWWSSSSSss L3-25407-00A BBU P/N: L4-25407-00 Model: BAT1S1P-A Pb e1 ASSEMBLED IN CHINA RoHS AsRPCB E248037 94V0 LSI CORP. 2010 ALL RIGHTS RESERVED 85083-04 85083-05 PCI Socket Edge of Motherboard Figure 5: Reinstalling the RAID 4. Secure the controller to the computer chassis with the bracket screw. Installing the Remote Mounting Board in the Computer Follow these steps to install the remote mounting board in the computer. 1. With the power to the chassis still turned off, and the power cords unplugged, make sure that the chassis is grounded and has no AC power. 2. Insert the remote mounting board in a PCI Express slot on the motherboard, as shown in Figure 6. NOTE: Some PCI Express slots support only PCI Express graphics cards; if the remote mounting board is installed in one of these slots, the board does not function. Refer to your computer documentation for information about the PCI Express slot. 3. Press down gently, but firmly, to seat the board correctly in the slot. Page 10 January 2011

! Li-ion Technical Support Screw Press Here Li Ion MH29577 WARNING: The battery used in this device may present a risk of fire or chemical burn if mistreated. DO NOT disassemble, heat above 60C, crush or puncture, short circuit external contacts, or dispose of in fire or water. Contains: Sony US454261A8T Ce l Rechargeable Li-Polymer Battery Pack Rating: 3.7V; 1.59 Ah; 5.9Wh Finished in China Press Here BBU S/N: SAYWWSSSSSss Model: BAT1S1P-A BBU P/N: L4-25407-00 L3-25407-00A LSI CORP. 2010 ALL RIGHTS RESERVED Pb e1 ASSEMBLED IN CHINA RoHS AsRPCB E248037 94V0 85083-06 Figure 6: Installing the Remote Mounting Board 4. Secure the remote mounting board to the computer chassis with the bracket screw. 5. Reinstall the computer cover and reattach the power cords. 6. Turn on the power to the computer. See the MegaRAID SAS Software User Guide for information about running the RAID configuration utility and installing the software drivers. Technical Support For assistance in installing, configuring, or running the LSIiBBU09 unit, contact your LSI Technical Support representative. NOTE: Record your controller serial number in a safe location in case you need to contact LSI about your RAID controller. Click the following link to access the LSI Technical Support page for storage and board support: http://www.lsi.com/support/storage/tech_support/index.html From this page, you can send an email or call Technical Support, or submit a new support request and view its status. Support Request: http://www.lsi.com/support/support_form.html January 2011 Page 11

Technical Support Telephone Support: http://www.lsi.com/support/storage/phone_tech_support/index.html NOTE: The international toll-free number does not require country-specific access codes. Page 12 January 2011