MegaRAID 6Gb/s SAS RAID Controllers
|
|
|
- Ambrose Miller
- 10 years ago
- Views:
Transcription
1 MegaRAID 6Gb/s SAS RAID Controllers User Guide , Revision D, June D
2 Revision History Version and Date Description of Changes Rev. D, June 2010 Added the SAS i, SAS i4e, and SAS i4e RAID controllers Rev. C, April 2010 Put this guide in the new template Rev. B, November 2009 Added the SAS i, SAS i, SAS i, and SAS i4e RAID controller Rev. A, July 2009 Added the SAS i, SAS 9260DE-8i, SAS e, and SAS 9280DE-8e RAID controllers Rev. A, June 2009 Documented the SAS i RAID controller Rev. A, March 2009 Initial release of this document. LSI and the LSI logo are trademarks or registered trademarks of LSI Corporation or its subsidiaries. All other brand and product names may be trademarks of their respective companies. LSI products are not intended for use in life-support appliances, devices, or systems. Use of any LSI product in such applications without written consent of the appropriate LSI officer is prohibited. Purchase of I 2 C components of LSI Corporation, or one of its sublicensed Associated Companies, conveys a license under the Philips I 2 C Patent Rights to use these components in an I 2 C system, provided that the system conforms to the I 2 C standard Specification as defined by Philips. Document Rev. D, June This document describes the current versions of the LSI Corporation MegaRAID SAS RAID controllers and will remain the official reference source for all revisions/releases of these products until rescinded by an update. LSI Corporation reserves the right to make changes to any products herein at any time without notice. LSI does not assume any responsibility or liability arising out of the application or use of any product described herein, except as expressly agreed to in writing by LSI; nor does the purchase or use of a product from LSI convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI or third parties. Copyright by LSI Corporation. All rights reserved. LSI, the LSI logo design, Fusion-MPT, and MegaRAID are trademarks or registered trademarks of LSI Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation. SUSE is a trademark and NetWare is a registered trademark of Novell, Inc. Red Hat is a registered trademark of Red Hat, Inc. UnixWare is a registered trademark of The Open Group. OpenServer is a trademark of Caldera International, Inc. Linux is a registered trademark of Linus Torvalds. All other brand and product names may be trademarks of their respective companies. Corporate Headquarters Website Milpitas, CA [email protected]
3 MegaRAID 6Gb/s SAS RAID Controllers User Guide Table of Contents Table of Contents Chapter 1: Overview Products Described in this Document Overview SAS Controller Descriptions General Description Configuration Scenarios Benefits of the SAS Interface PCI Express Architecture Operating System Support Summary of SAS RAID Controller Characteristics SAS Features SAS Array Limitations SATA II Features PCI Express Performance Usability Features Flexibility Features Drive Roaming Drive Migration Hardware Specifications Technical Support Chapter 2: MegaRAID SAS Hardware Installation Requirements Quick Installation Detailed Installation After Installing the RAID Controller SAS Device Cables and Connectors Connecting a SAS RAID Controller with Internal Connectors to Drives Connecting a SAS RAID Controller with External Connectors to a Drive Enclosure Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID SAS 9240 RAID Controllers MegaRAID SAS 9260 RAID Controllers MegaRAID SAS 9261 RAID Controller MegaRAID SAS 9280 RAID Controllers MegaRAID SAS 6Gb/s RAID Controller Characteristics Technical Specifications RAID Controller Specifications Array Performance Features Fault Tolerance Electrical Characteristics Safety Characteristics LSI Corporation Confidential. Advance Copy Not for General Distribution June 2010 Page 3
4 Table of Contents MegaRAID 6Gb/s SAS RAID Controllers User Guide Appendix A: Glossary of Terms and Abbreviations Appendix B: Customer Feedback B.1 Reader s Comments Page 4 June 2010
5 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview Products Described in this Document Chapter 1 Overview This chapter provides an overview of the MegaRAID 6Gb/s Serial Attached SCSI/Serial ATA II controllers with RAID control capability. Section 1.1, Products Described in this Document Section 1.2, Overview Section 1.3, SAS Controller Descriptions Section 1.4, General Description Section 1.5, Configuration Scenarios Section 1.6, Benefits of the SAS Interface Section 1.7, Summary of SAS RAID Controller Characteristics Section 1.8, Hardware Specifications Section 1.9, Technical Support 1.1 Products Described in this Document This document is the primary reference and user s guide for the LSI MegaRAID Serial Attached SCSI/SATA II RAID controllers based on the 6Gb/s SAS/SATA RAID On-a-Chip devices. This document contains complete installation instructions for these RAID controllers and includes specifications for them. The MegaRAID 6Gb/s Serial Attached SCSI (SAS) RAID controller family consists of the following controllers: MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with an Internal Connector MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with an Internal Connector MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors MegaRAID SAS 9260DE-8i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors MegaRAID SAS i PCI Express 2.0 Standard-Height Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors MegaRAID SAS i4e PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with an Internal Connector and an External Connector LSI Corporation Confidential. Advance Copy Not for General Distribution June 2010 Page 5
6 Chapter 1: Overview Overview MegaRAID 6Gb/s SAS RAID Controllers User Guide MegaRAID SAS e PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with External Connectors MegaRAID SAS 9280DE-8e PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller with External Connectors MegaRAID SAS i4e PCI Express 2.0 Standard-Height Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors and an External Connector MegaRAID SAS i4e PCI Express 2.0 Standard-Height Serial-Attached SCSI/SATA II Disk Array Controller with Internal Connectors and an External Connector 1.2 Overview The MegaRAID 6Gb/s SAS RAID controllers are high-performance intelligent PCI Express-to-SCSI/Serial ATA II adapters with RAID control capability. MegaRAID 6Gb/s SAS RAID controllers provide reliability, high performance, and fault-tolerant drive subsystem management. They are an ideal RAID solution for the internal storage of workgroup, departmental, and enterprise systems. MegaRAID 6Gb/s SAS RAID controllers offer a cost-effective way to implement RAID in a server. SAS technology brings a wealth of options and flexibility with the use of SAS and Serial ATA (SATA) II devices within the same storage infrastructure. However, SAS and SATA devices bring individual characteristics that make each one a more suitable choice depending on your storage needs. MegaRAID gives you the flexibility to combine these two similar technologies on the same controller, within the same enclosure, and in the same virtual drive. NOTE: LSI recommends that you carefully assess any decision to mix SAS drives and SATA drives within the same virtual drives. Although you can mix drives, LSI strongly discourages the practice. LSI offers a family of MegaRAID SAS RAID controllers that address the needs for both internal and external solutions. The MegaRAID 6Gb/s SAS RAID controllers are based on the LSI first-to-market SAS IC technology and proven MegaRAID technology. As second-generation PCI Express RAID controllers, these controllers address the growing demand for increased data throughput and scalability requirements across midrange and enterprise-class server platforms. These controllers provide: 6.0 Gb/s Serial Attached SCSI performance 3.0 Gb/s SATA II performance Eight-lane, 5-Gb/s PCI Express host interface The SAS 9260DE-8i RAID controller and the SAS 9280DE-8i RAID controller offer data security using disk encryption. This feature offers the ability to encrypt data on drives and use disk-based key management to provide data security. This solution provides data protection in the event of theft or loss of physical drives. With self-encrypting drives, if you remove a drive from its storage system or the server in which it is housed, the data on that drive is encrypted and useless to anyone who attempts to access without the appropriate security authorization. Page 6 June 2010
7 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview SAS Controller Descriptions For more information about self-encrypting drives, refer to the MegaRAID SAS Software User s Guide. The SAS 9260 RAID controllers, the SAS 9261 RAID controllers, and the SAS 9280 RAID controllers use the LSI intelligent Battery Backup Unit 07 (LSIiBBU-07) to provide cached data protection and allow system builders to protect cached data even during the most catastrophic system failures. In addition,the SAS i, SAS i4e, and SAS i4e RAID controllers use the LSI intelligent Battery Backup Unit 08 (LSIiBBU-08). Refer to the battery backup documentation on the MegaRAID Universal Software Suite CD for more information about this battery backup unit. The SAS controllers support the ANSI Serial Attached SCSI standard, version 2.0. In addition, the controller supports the SATA II protocol defined by the Serial ATA specification, version 1.0a. Supporting both the SAS interface and the SATA II interface, the SAS controller is a versatile controller that provides the backbone of both server and high-end workstation environments. Each port on the SAS RAID controller supports SAS devices, SATA II devices, or both, using the following protocols: SAS Serial SCSI Protocol (SSP), which enables communication with other SAS devices SATA II, which enables communication with other SATA II devices Serial Management Protocol (SMP), which communicates topology management information directly with an attached SAS expander device Serial Tunneling Protocol (STP), which enables communication with a SATA II device through an attached expander 1.3 SAS Controller Descriptions The 6Gb/s SAS RAID controllers are described as follows: The MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller is a PCI-Express 2.0, half-size, full-height RAID controller based on the LSISAS2008 PCI Express-SAS/SATA I/O Processor chip. The MegaRAID SAS i controls four internal 6-Gb/s SAS/SATA ports through one SFF-8087 x4 internal mini SAS connector. The MegaRAID SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller is a PCI-Express 2.0, half-size, full-height RAID controller based on the LSISAS2008 PCI Express-SAS/SATA I/O Processor chip. The MegaRAID SAS i controls eight internal 6-Gb/s SAS/SATA ports through two SFF-8087 x4 internal mini SAS connectors. The MegaRAID 6Gb/s SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls four internal SAS/SATA ports through one SFF-8087 x4 internal mini SAS connector. The MegaRAID 6Gb/s SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls eight internal SAS/SATA ports through two SFF-8087 x4 internal mini SAS connectors. June 2010 Page 7
8 Chapter 1: Overview General Description MegaRAID 6Gb/s SAS RAID Controllers User Guide The MegaRAID 6Gb/s SAS 9260DE-8i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls eight internal SAS/SATA ports through two SFF-8087 x4 internal mini SAS connectors and offers data security using disk encryption. The MegaRAID 6Gb/s SAS i PCI Express 2.0 Standard-Height Serial-Attached SCSI/SATA II Disk Array Controller controls 16 internal SAS/SATA ports through four SFF-8087 x4 internal mini SAS connectors. The MegaRAID 6Gb/s SAS i PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls eight internal SAS/SATA ports through two SFF-8087 mini-sas 4i connectors. The MegaRAID 6Gb/s SAS i4e PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls four internal SAS/SATA ports through one SFF-8087 x4 internal mini SAS connector and four external SAS/SATA ports through one SFF-8088 x4 external mini SAS connector. The MegaRAID 6Gb/s SAS e PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls eight external SAS/SATA ports through two SFF-8088 x4 external mini SAS connectors. The MegaRAID 6Gb/s SAS 9280DE-8e PCI Express 2.0 Low-Profile Serial-Attached SCSI/SATA II Disk Array Controller controls eight external SAS/SATA ports through two SFF-8088 x4 external mini SAS connectors and offers data security using disk encryption. The MegaRAID 6Gb/s SAS i4e PCI Express 2.0 Standard-Height Serial-Attached SCSI/SATA II Disk Array Controller controls 16 internal SAS/SATA ports through four SFF-8087 x4 internal mini SAS connector and four external SAS/SATA ports through one SFF-8088 x4 external mini SAS connector. The MegaRAID 6Gb/s SAS i4e PCI Express 2.0 Standard-Height Serial-Attached SCSI/SATA II Disk Array Controller controls 24 internal SAS/SATA ports through six SFF-8087 x4 internal mini SAS connector and four external SAS/SATA ports through one SFF-8088 x4 external mini SAS connector. 1.4 General Description The MegaRAID 6Gb/s SAS RAID controllers bring 6.0 Gb/s Serial Attached SCSI and 3.0 Gb/s SATA II performance to host adapter, workstation, and server designs. The controllers support internal storage devices and external storage devices, which allow you to use a system that supports enterprise-class SAS drives and desktop-class SATA II drives. Each MegaRAID 6Gb/s SAS RAID controller can connect to drives directly and can use expanders to connect to additional drives. Simplified cabling between devices is an additional benefit. These SAS controllers are based on the LSISAS2108 RAID On-a-Chip (ROC) device or the LSISAS2008 PCI Express-SAS/SATA I/O Processor chip. These devices are compliant with the Fusion-MPT architecture and provides a PCI Express x8 interface. NOTE: All of these RAID controllers provide an x8 PCI Express 2.0 interface. Page 8 June 2010
9 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview Configuration Scenarios The LSISAS2108 ROC device provides an eight-lane, 5-Gb/s PCI Express host interface, eight 6.0 Gb/s SAS ports or eight 3.0 Gb/s SATA ports, and a full-featured, hardware-based RAID implementation. In addition, it integrates a high-speed DDR/DDR2 800 MHz SDRAM interface with a hardware RAID assist engine for parity calculations. The LSISAS2108 ROC device provides the maximum benefits of a RAID system and enables you to configure the system to satisfy your system requirements. The LSISAS2108 ROC device increases system performance and provides fault-tolerant data storage. The LSISAS2108 supports data striping across multiple drives, which reduces drive access time because multiple drives simultaneously read or write data. The LSISAS2108 ROC device backs up data with either data mirroring or a parity block. Either backup method enables you to recover lost data in the event of a drive failure. You can select the data backup method that best suits your needs. A hardware RAID assist exclusive-or (XOR) engine speeds parity generation and checking and reduces system-access times. The SAS RAID controllers integrate eight high-performance SAS/SATA II PHYs and a PCI Express bus master DMA core. Each of the eight PHYs is capable of 6.0 Gb/s SAS link rates and 3.0 Gb/s SATA II link rates. These devices adhere to the PCI Express Specification, Revision 2.0. The PCI Express software is backward compatible with previous revisions of the PCI bus and PCI-X bus. The SAS RAID controllers support the SAS protocol as described in the Serial Attached SCSI Standard, version 2.0. The controllers also support the Serial ATA II (SATA II) protocol defined by the Serial ATA Specification, Version 1.0a and the Serial ATAII; Extension to the Serial ATA Specification, Version 1.1. SATA II is an extension to SATA 1.0a. In addition, the SAS RAID controllers support the following SATA II features: 3Gb/s SATA II Staggered spin-up Hot plug Native command queuing Activity and fault indicators for each PHY Port selector (for dual-port drives) Each port on the SAS controllers supports SAS devices, SATA II devices, or both using SSP, SMP, STP, and SATA II. SSP enables communication with other SAS devices. SATA II enables the SAS controllers to communicate with other SATA II devices. 1.5 Configuration Scenarios You can use the SAS RAID controllers in three main scenarios: Low-end, internal SATA II configuration: In this configuration, use the RAID controller as a high-end SATA II compatible controller that connects up to eight drives either directly or through a port expander. This configuration is mostly for low-end or entry servers. Enclosure management is provided through an out-of-band I 2 C bus. Side bands of both types of internal SAS connectors support the SFF-8485 (SGPIO) interface. Midrange internal SAS configuration: This configuration is like the internal SATA II configurations, but with high-end SAS drives. This configuration is more suitable for low-range to midrange servers. June 2010 Page 9
10 Chapter 1: Overview Benefits of the SAS Interface MegaRAID 6Gb/s SAS RAID Controllers User Guide High-end external SAS/SATA II configuration: This configuration is for external connectivity using SATA II drives, SAS drives, or both. External enclosure management is supported through in-band, SCSI-enclosed storage. The configuration must support STP and SMP. Figure 1 shows a direct-connect configuration. The Inter-IC (I 2 C) interface communicates with peripherals. The external memory bus provides a 32-bit memory bus, parity checking, and chip select signals for pipelined synchronous burst static random access memory (PSBRAM), nonvolatile static random access memory (NVSRAM), and Flash ROM. Figure 1: Example of an LSI SAS Direct-Connect Application SAS/SATA II Device SAS/SATA II Device SAS/SATA II Device SAS PCI Express RAID Controller 32-Bit Memory Address/Data Bus I 2 C Interface Flash ROM/ PSBRAM/ NVSRAM I 2 C SAS/SATA II Device Figure 2 shows an example of a SAS RAID controller configured with an LSISASx12 expander that is connected to SAS drives, SATA II drives, or both. Figure 2: PCI Express Interface Example of an LSI SAS RAID Controller Configured with an LSISASx12 Expander PCI Express Interface SAS RAID Controller LSISAS2108 PCI Express to SAS ROC 8 Peripheral Bus 72-bit DDR/DDR2 with ECC Interface Flash ROM/ NVSRAM/ I 2 C/UART SRAM SDRAM SRAM LSISASx12 Expander LSISASx12 Expander 1.6 Benefits of the SAS Interface SAS is a serial, point-to-point, enterprise-level device interface that leverages the proven SCSI protocol set. SAS is a convergence of the advantages of SATA II, SCSI, and Fibre Channel, and is the future mainstay of the enterprise and high-end workstation storage markets. SAS offers a higher bandwidth per pin than parallel SCSI, and it improves signal and data integrity. Page 10 June 2010
11 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview Summary of SAS RAID Controller Characteristics The SAS interface uses the proven SCSI command set to ensure reliable data transfers, while providing the connectivity and flexibility of point-to-point serial data transfers. The serial transmission of SCSI commands eliminates clock-skew challenges. The SAS interface provides improved performance, simplified cabling, smaller connectors, lower pin count, and lower power requirements when compared to parallel SCSI. SAS controllers leverage a common electrical and physical connection interface that is compatible with Serial ATA technology. The SAS and SATA II protocols use a thin, 7-wire connector instead of the 68-wire SCSI cable or 26-wire ATA cable. The SAS/SATA II connector and cable are easier to manipulate, allow connections to smaller devices, and do not inhibit airflow. The point-to-point SATA II architecture eliminates inherent difficulties created by the legacy ATA master-slave architecture, while maintaining compatibility with existing ATA firmware PCI Express Architecture PCI Express is a local bus system designed to increase data transfers without slowing down the central processing unit (CPU). You can install MegaRAID PCI Express RAID controllers in PCI Express computer systems with a standard bracket type. With these controllers in your system, you can connect SAS devices and SATA II devices over the bus. NOTE: Some PCI-E slots support PCI-E graphics cards only; if a RAID controller is installed on those PCI-E slots, it will not function. PCI Express goes beyond the PCI specification in that it is intended as a unifying I/O architecture for various systems: desktops, workstations, mobile devices, servers, communications, and embedded devices Operating System Support The MegaRAID 6Gb/s SAS RAID controllers supports the following operating systems: Windows Vista, Windows Server 2003, and Windows Server 2008 Red Hat Linux SUSE Linux Novell NetWare SCO OpenServer SCO UnixWare Solaris FreeBSD To download the latest operating system drivers, go to: The MegaRAID 6Gb/s SAS RAID controllers use Fusion-MPT architecture for all major operating systems, thinner drivers, and better performance. 1.7 Summary of SAS RAID Controller Characteristics This section summarizes the features and benefits of the MegaRAID 6Gb/s SAS RAID controllers. It contains information on SAS features, SATA II features, PCI performance, integration, usability, and flexibility. The MegaRAID 6Gb/s SAS RAID controllers have the following features: June 2010 Page 11
12 Chapter 1: Overview Summary of SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controllers User Guide PCI Express x8 lane width (with support for x16 connections) PCI Express performance up to 5Gb/s per lane Support for 512-Mbyte DDR2 800 MHz on-board SDRAM intelligent battery-backed module One internal connector for the SAS i, SAS i, and SAS i4e RAID controllers Two internal connectors for the SAS i, SAS i, SAS i, and SAS 9260DE-8i RAID controllers Four internal connectors for the SAS i RAID controller and the SAS i4e RAID controller Six internal connectors for the SAS i4e RAID controller One external connector for the SAS i4e, SAS i4e, and SAS i4e RAID controllers Two external connectors for the SAS e RAID controller and the SAS 9280DE-8e RAID controller Support for RAID levels 0, 1, 5, 6, 00, 10, 50, and 60 Advanced array configuration and management utilities Support for global hot spares and dedicated hot spares Support for user-defined stripe sizes: 8, 16, 32, 64, 128, 256, 512, or 1024 KB Advanced array configuration and management utilities offer: Online capacity expansion to add space to an existing drive or new drive Online RAID level migration Drive migration Drive roaming No reboot necessary after expansion Load balancing Media scan User-specified rebuild rate (specifying the percentage of system resources to use from 0 percent to 100 percent) 32-Kbyte nonvolatile random access memory (NVRAM) for storing RAID system configuration information; the MegaRAID SAS firmware is stored in flash ROM for easy upgrade SAS Features The following list describes the SAS features of the RAID controllers: Provides four fully independent PHYs or eight fully independent PHYs, depending on the controller Supports 6Gb/s and 3Gb/s SAS data transfers per PHY Supports SMP to communicate topology management information Supports SSP to enable communication with other SAS devices Supports STP to enable communication with a SATA II device through an attached expander Provides a serial, point-to-point, enterprise-level storage interface Simplifies cabling between devices Page 12 June 2010
13 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview Summary of SAS RAID Controller Characteristics Provides a scalable interface that supports up to 240 devices through the use of expanders NOTE: The number of devices varies depending on the MegaRAID product. Check the LSI website ( for specific details about your product. Supports wide ports consisting of 2, 3, or 4 PHYs within a single quad port Supports narrow ports consisting of a single PHY Transfers data using SCSI information units SAS Array Limitations This section describes the array limitations of the MegaRAID 6Gb/s SAS RAID controllers. These limitations include the number of drives supported per controller, the maximum number of drives per controller, and the maximum number of virtual drives allowed per controller. Table 1 lists the array limitations for the 6Gb/s SAS RAID controllers. Table 1: SAS RAID Controller Array Limitations Specification SAS i SAS i SAS i Maximum virtual drives per controller Maximum drive groups per controller Maximum virtual drives per drive group Maximum drives per drive group Maximum drives per controller 16* 16* Maximum hot spares per controller Maximum spans per virtual drive Maximum enclosures per port** Number of ports * Can support up to 64 devices, but only 16 can be used in a RAID configuration. ** Assumes one Storage Enclosure Processor (SEP) per enclosure. SAS i SAS i SAS i SAS i/4e SAS e SAS i4e SAS i4e The maximum numbers in Table 1 depend on how many physical devices you have connected to the RAID controller. For example, the maximum number of drive groups is equal to the number of drives that are supported by the controller. Thus, for the SAS i RAID controller, the maximum number of drive groups per controller is eight, which is based on the maximum number of physical devices that you can connected. In addition, the maximum number of hot spares per controller is equal to the maximum number of drives per controller. June 2010 Page 13
14 Chapter 1: Overview Summary of SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controllers User Guide Although you can have up to 16 virtual drives per drive group and up to 16 drive groups per controller (depending on the controller), there is a limit of 64 virtual drives per controller. These RAID controllers support 64-bit logical block addressing (LBA), which makes it possible to connect a large number of drives to the RAID controller, directly and through expanders. However, the actual number of drives that you can attach depends on the limits listed in Table 1 rather than by actual RAID volume capacity SATA II Features The following list describes the SATA II features of the RAID controllers: Supports SATA II data transfers of 3Gb/s Supports STP data transfers of 3Gb/s Provides a serial, point-to-point storage interface Simplifies cabling between devices Eliminates the master-slave construction used in parallel ATA Allows addressing of multiple SATA II targets through an expander Allows multiple initiators to address a single target (in a failover configuration) through an expander PCI Express Performance The following list describes the PCI Express performance features of the RAID controllers: Provides a PCI Express interface that does the following: Supports a dedicated PCI Express bus Supports x8 lane configuration Supports transfer rates of up to 5Gb/s per lane Complies with the PCI Express Specification, Revision 2.0 Provides unequaled performance through the Fusion-MPT architecture Provides high throughput and low CPU utilization to offload the host processor Usability Features The following list describes the usability features of the RAID controllers: Simplifies cabling with point-to-point, serial architecture Supports smaller, thinner cables that do not restrict airflow Provides drive spin-up sequencing control Provides one LED signal for each PHY to indicate link activity (this is a fault LED only for controllers with internal port connectors) NOTE: The SAS e RAID controller and the SAS 9280DE-8e RAID controller do not have any LEDs to indicate link activity. Provides an I 2 C interface for enclosure management Supports the internal SAS Sideband signal SFF-8485 (SGPIO) interface Flexibility Features These features increase the flexibility of the RAID controllers: Supports a Flash ROM interface, a nonvolatile static RAM (NVSRAM) interface, and a pipelined synchronous burst SRAM (PSBRAM) interface Page 14 June 2010
15 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview Summary of SAS RAID Controller Characteristics Offers a flexible programming interface to tune I/O performance Allows mixed connections to SAS targets or SATA II targets Leverages compatible connectors for SAS connections and SATA II connections Allows grouping of up to four PHYs in a single quad port to form a wide port Allows programming of the World Wide Name Drive Roaming Drive roaming occurs when the drives are changed to different ports on the same controller. When the drives are placed on different channels, the controller detects the RAID configuration from the configuration data on the drives. Configuration data is saved in both the NVRAM on the RAID controller and on the drives attached to the controller. This action maintains the integrity of the data on each drive, even if the drives have changed their physical device ID. NOTE: If you move a drive that is being rebuilt, the rebuild operation will restart, not resume. Follow these steps to use drive roaming: 1. Turn off power to the server and all drives, enclosures, and system components. Disconnect the power cords from the system. 2. Open the host system by following the instructions in the host system technical documentation. 3. Move the drives to different positions on the backplane to change the targets. 4. Determine the SAS target requirements. 5. Perform a safety check. a. Make sure that the drives are inserted correctly. b. Close the cabinet of the host system. 6. Reconnect the power cords to the system. 7. Turn on the power to the system. The controller then detects the RAID configuration from the configuration data on the drives Drive Migration Drive migration is the transfer of a set of drives in an existing configuration from one controller to another. The drives must remain on the same channel and must be reinstalled in the same order as in the original configuration. The controller to which you migrate the drives cannot have an existing configuration. NOTE: Partial configurations, including individual virtual drives, can be migrated. NOTE: Drive roaming and drive migration cannot be supported at the same time. Follow these steps to migrate drives: June 2010 Page 15
16 Chapter 1: Overview Hardware Specifications MegaRAID 6Gb/s SAS RAID Controllers User Guide 1. Make sure that you clear the configuration on the system to which you migrate the drives, to prevent a configuration data mismatch between the drives and the NVRAM. NOTE: When you migrate drives, move only the drives that make up the virtual drive (not all of the drives in an array), so you do not see an NVRAM mismatch error (providing a configuration is on the destination controller). The NVRAM mismatch error appears only if you move all of the drives to the other controller. 2. Turn off power to the server and all drives, enclosures, and system components. Disconnect the power cords from the systems. 3. Open the host system by following the instructions in the host system technical documentation. 4. Either remove the SAS cable connectors from the internal drives, or remove the shielded cables from the external drives that you want to migrate. a. Make sure that pin 1 on the cable matches pin 1 on the connector. b. Make sure that the SAS cables conform to all SAS specifications. 5. Remove the drives from the first system, and insert them into drive bays on the second system. 6. Connect the SAS cables to the drives in the second system. 7. Determine the SAS target requirements. 8. Perform a safety check. a. Make sure that all of the cables are attached correctly. b. Make sure that the RAID controller is installed correctly. c. Close the cabinet of the host system. 9. Reconnect the power cords to the system. 10. Turn on the power to the system. The controller detects the RAID configuration from the configuration data on the drives. 1.8 Hardware Specifications You can install the MegaRAID 6Gb/s SAS RAID controllers in a computer with a motherboard that has a PCI Express slot. Table 2 describes the hardware configuration features for the MegaRAID 6Gb/s SAS RAID controllers. Page 16 June 2010
17 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 1: Overview Hardware Specifications Table 2: MegaRAID 6Gb/s SAS RAID Controller Features Specification MegaRAID SAS 9240, SAS 9260, SAS 9261, and SAS 9280 RAID Controllers RAID levels 0, 1, 5, 6, 00, 10, 50, 60 Devices supported per port Up to 15 SAS devices or SATA II devices (such as drives and expanders) Number of ports MegaRAID SAS i RAID controller Four ports through one SFF-8087 x4 internal mini SAS connector MegaRAID SAS i RAID controller Eight ports through two SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i RAID controller Four ports through one SFF-8087 x4 internal mini SAS connector MegaRAID SAS i RAID controller Eight ports through two SFF-8087 x4 internal mini SAS connectors MegaRAID SAS 9260DE-8i RAID controller Eight ports through two SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i RAID controller 16 ports through four SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i RAID controller Eight ports through two SFF-8087 mini-sas 4i connectors MegaRAID SAS i4e RAID controller Four ports through one SFF-8087 x4 internal mini SAS connector and four ports through one SFF-8088 x4 external mini SAS connector MegaRAID SAS e RAID controller Eight ports through two SFF-8088 x4 external mini SAS connectors MegaRAID SAS 9280DE-8e RAID controller Eight ports through two SFF-8088 x4 external mini SAS connectors MegaRAID SAS i4e RAID controller 16 ports through four SFF-8087 x4 internal mini SAS connectors and four ports through one SFF-8088 x4 external mini SAS connector MegaRAID SAS i4e RAID controller 24 ports through six SFF-8087 x4 internal mini SAS connectors and four ports through one SFF-8088 x4 external mini SAS connector Data transfer rate Up to 6Gb/s per PHY Bus PCI Express 2.0 Cache function Write-back, write-through, adaptive read ahead, non-read ahead, read ahead, cache I/O, direct I/O Multiple virtual drives per controller Up to 64 (this value is dependent on the firmware) Online capacity expansion Yes Dedicated and global hot spares Yes Hot-swap devices supported Yes Non-drive devices supported Yes Mixed capacity drives supported Yes Number of external connectors MegaRAID SAS i4e RAID controller One SFF-8088 x4 external mini SAS connector MegaRAID SAS e RAID controller Two SFF-8088 x4 external mini SAS connectors MegaRAID SAS 9280DE-8e RAID controller Two SFF-8088 x4 external mini SAS connectors MegaRAID SAS i4e RAID controller One SFF-8088 x4 external mini SAS connector MegaRAID SAS i4e RAID controller One SFF-8088 x4 external mini SAS connector June 2010 Page 17
18 Chapter 1: Overview Technical Support MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 2: MegaRAID 6Gb/s SAS RAID Controller Features (Continued) Specification Number of internal connectors Hardware exclusive OR (XOR) assistance Direct I/O Architecture MegaRAID SAS 9240, SAS 9260, SAS 9261, and SAS 9280 RAID Controllers MegaRAID SAS i RAID controller One SFF-8087 x4 internal mini SAS connector MegaRAID SAS i RAID controller Two SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i RAID controller One SFF-8087 x4 internal mini SAS connector MegaRAID SAS i RAID controller Two SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i RAID controller Four SFF-8087 x4 internal mini SAS connectors MegaRAID SAS 9260DE-8i RAID controller Two SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i RAID controller Two SFF-8087 mini-sas 4i connectors MegaRAID SAS i4e RAID controller One SFF-8087 x4 internal mini SAS connector MegaRAID SAS i4e RAID controller Four SFF-8087 x4 internal mini SAS connectors MegaRAID SAS i4e RAID controller Six SFF-8087 x4 internal mini SAS connectors Yes Yes Fusion-MPT 1.9 Technical Support For assistance installing, configuring, or running your MegaRAID 6Gb/s SAS RAID controller, contact LSI Technical Support. Click the following link to access the LSI Technical Support page for storage and board support: From this page, you can send an or call Technical Support, or submit a new service request and view its status. NOTE: Record your controller serial number in a safe location in case you need to contact LSI about your RAID controller. Phone Support: NOTE: The international toll-free number does not require country-specific access codes. Page 18 June 2010
19 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 2: MegaRAID SAS Hardware Installation Requirements Chapter 2 MegaRAID SAS Hardware Installation This chapter describes the procedures you can follow to install the MegaRAID 6Gb/s Serial Attached SCSI/Serial ATA II controllers with internal and external connectors. Section 2.1, Requirements Section 2.2, Quick Installation Section 2.3, Detailed Installation Section 2.4, After Installing the RAID Controller Section 2.5, SAS Device Cables and Connectors 2.1 Requirements The following items are required to install a MegaRAID 6Gb/s SAS RAID controller: A MegaRAID SAS 92xx RAID controller A host system with an available x8 PCI Express 2.0 slot NOTE: These controllers also work in PCI Express first generation slots. The PCI Express software is backward compatible with previous revisions of the PCI bus and the PCI-X bus. The MegaRAID Universal Software Suite CD, which contains the drivers and documentation The necessary internal cables, external cables, or both SAS drives or SATA II drives NOTE: LSI strongly recommends using an uninterruptible power supply. 2.2 Quick Installation The following steps are for quick installation of your MegaRAID 6Gb/s SAS RAID controller. These steps are for experienced computer users or installers. Section 2.3, Detailed Installation contains the steps for all others to follow. 1. Turn off the power to the system, all drives, enclosures, and system components, and disconnect the PC power cord. 2. Open the cabinet of the host system by following the instructions in the host system technical documentation. 3. Check the jumper settings to make sure that they are in the desired position. The jumpers are set at the factory and you usually do not need to change them. June 2010 Page 19
20 Chapter 2: MegaRAID SAS Hardware Installation Detailed Installation MegaRAID 6Gb/s SAS RAID Controllers User Guide NOTE: See Chapter 3, MegaRAID SAS RAID Controller Characteristics for detailed information about the jumpers and the connectors. 4. Install the MegaRAID 6Gb/s SAS RAID controller in the server, and connect SAS devices or SATA II devices to it. Make sure that the cables you use conform to all specifications. 5. Perform a safety check. a. Make sure that all cables are attached correctly. b. Make sure that the RAID controller is installed correctly. c. Close the cabinet of the host system. 6. Reconnect the power cords to the system. 7. Turn on the power to the system. Make sure that the power is turned on to any external drives, before the power is turned on to the host computer. If the computer is powered up before these devices, the devices might not be recognized. 2.3 Detailed Installation This section provides detailed instructions for installing your MegaRAID 6Gb/s SAS RAID controller. 1. Unpack the MegaRAID 6Gb/s SAS RAID controller. Unpack and remove your RAID controller. Inspect it for damage. If it appears damaged, or if any of the following items are missing, contact your LSI Customer and Technical Support representative. The RAID controller is shipped with the following items: A CD containing MegaRAID drivers for supported operating systems, an electronic version of this user s guide, and other related documentation A license agreement Warranty information 2. Turn off the power to the system. Turn off the power to the computer, and disconnect the AC power cord. Remove the computer cover. Refer to the system documentation for instructions. Before you install the controller, make sure that the computer is disconnected from the power and from any networks. 3. Review the RAID controller jumpers and connectors. The jumpers are set at the factory, and you usually do not need to change them. See Chapter 3, MegaRAID SAS RAID Controller Characteristics for diagrams of the MegaRAID 6Gb/s SAS RAID controllers with their jumpers and connectors. 4. Install the RAID controller. Select a PCI Express slot, and align the controller s PCI Express bus connector to the slot. Press down gently, but firmly, to make sure that the card is seated correctly in the slot. Secure the bracket to the computer chassis with the bracket screw. Figure 3 shows the installation of the MegaRAID SAS i RAID controller in a PCI Express slot. Page 20 June 2010
21 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 2: MegaRAID SAS Hardware Installation Detailed Installation NOTE: Some PCI-E slots support PCI-E graphics cards only; if a RAID controller is installed on those PCI-E slots, it will not function. Figure 3: Example of the MegaRAID SAS i Board Installation in a PCI Express Slot Bracket Screw Press here Press here Edge of Motherboard PCI-e slot 64-bit slots (3.3 V) 32-bit slots (3.3 V) 5. Configure and install the SAS devices, SATA II devices, or both in the host computer case. Refer to the documentation for the devices for any preinstallation configuration requirements. 6. Connect the RAID controller to the devices. Use SAS cables to connect SAS devices, SATA II devices, or both to the MegaRAID 6Gb/s SAS RAID controller. See Section 2.5, SAS Device Cables and Connectors for SAS cable and connector information. See Section 2.5.1, Connecting a SAS RAID Controller with Internal Connectors to Drives for information about connecting the controller to drives. The maximum cable length is 10 meters ( in.). You can connect one device per SAS PHY unless you use an expander. System throughput problems can occur if the SAS cables are not the correct type. To minimize the potential for problems, use the following guidelines: a. Use cables no longer than 10 meters ( in.). (LSI recommends using shorter cables, if possible.) b. Use cables that meet the SAS specification. c. Route the SAS cables carefully. June 2010 Page 21
22 Chapter 2: MegaRAID SAS Hardware Installation After Installing the RAID Controller MegaRAID 6Gb/s SAS RAID Controllers User Guide 7. Turn on the power to the system. Reinstall the computer cover, and reconnect the AC power cords. Turn power on to the host computer. Make sure that the power is turned on to the SAS devices, SATA II devices, or both before or at the same time that the power is turned on to the host computer. If the computer is powered up before these devices, the devices might not be recognized. During boot, a BIOS message appears. The firmware takes several seconds to initialize. The configuration utility prompt times out after several seconds. The second portion of the BIOS message shows the MegaRAID 6Gb/s SAS RAID controller number, firmware version, and cache SDRAM size. The numbering of the controllers follows the PCI slot scanning order used by the host motherboard. 8. Run the WebBIOS Configuration Utility. Run the WebBIOS Configuration Utility to configure the drive groups and the virtual drives. When the message Press CTRL+H for WebBIOS appears on the screen, immediately press CTRL+H to run the utility. 9. Install the operating system driver. The SAS RAID controllers can operate under various operating systems. To operate under these operating systems, you must install the software drivers. The MegaRAID Universal Software Suite CD includes software drivers for the supported operating systems, along with documentation. You can view the supported operating systems and download the latest drivers for RAID controllers on the LSI website at: For information about installing the driver, refer to the MegaRAID SAS Device Driver Installation User s Guide on the MegaRAID Universal Software Suite CD. Be sure to use the latest service packs provided by the operating system manufacturer and to review the readme file that accompanies the driver. 2.4 After Installing the RAID Controller After you install the MegaRAID 6Gb/s SAS RAID controller, you must configure the controller and install the operating system driver. The MegaRAID SAS Software User s Guide instructs you on the configuration options and how to set them on your MegaRAID 6Gb/s SAS RAID controller. The MegaRAID SAS Device Driver Installation User s Guide provides detailed installation instructions for operating system drivers. 2.5 SAS Device Cables and Connectors This section describes the cables and the connectors used on the SAS controllers and provides step-by-step instructions for connecting SAS drives, SATA II drives, or both to the SAS RAID controller. The SAS and SATA II protocols use a thin, 7-wire connector instead of the 68-wire SCSI cable or 40-wire ATA cable. NOTE: Use only straight SAS cables, not crossover SAS cables. Page 22 June 2010
23 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 2: MegaRAID SAS Hardware Installation SAS Device Cables and Connectors Figure 4 shows the SAS cable that connects the internal connectors on a SAS RAID controller to SAS drives, SATA II drives, or both. Figure 4: Internal SAS Cable for Connection to SAS Drives, SATA II Drives, or Both HDD Connector Power Connector Figure 5 shows the SATA II device plug connector that connects a SAS RAID controller with internal connectors to the host receptacle connector on a backplane. A SATA II connector consists of a signal connector and a power connector. Figure 5: Serial ATA Signal Connector (pin 1) SATA II Connectors Device Plug Connector Serial ATA Power Connector (pin 1) Host Receptacle Connector Figure 6 shows SAS connectors and SATA II connectors on SAS drives and SATA II drives, respectively. Cables connect internal connectors on the RAID controllers to connectors on SAS drives, SATA II drives, or both. Both SAS drives and SATA II drives can connect to SAS backplane receptacle connectors. The difference between the SAS connector and the SATA II connector is the bridge between the SAS primary physical link and the power connector on the SAS controller, which the SATA II connector does not have. June 2010 Page 23
24 Chapter 2: MegaRAID SAS Hardware Installation SAS Device Cables and Connectors MegaRAID 6Gb/s SAS RAID Controllers User Guide NOTE: SAS backplane connectors accept SAS drives or SATA II drives, but SATA II backplane connectors cannot accept SAS drives. Figure 6: SAS Primary Physical Link SAS Plugs and SATA II Plugs and SAS Backplane Receptacle Connector Serial Attached SCSI SAS Secondary Physical Link Power SAS Backplane Receptacle Connector SATA II Physical Link Power Serial ATA Power SAS Secondary Physical Link SATA II/SAS Primary Physical Link Note: SATA II backplane connectors do not accept SAS drives. The following subsections provide step-by-step instructions for connecting the SAS RAID controllers to SAS drives and SATA II drives, either directly or through an expander Connecting a SAS RAID Controller with Internal Connectors to Drives This section provides step-by-step instructions for connecting the SAS cable from the internal connectors on the RAID controller to SAS drives and SATA II drives. Follow these steps to connect your RAID controller with internal SAS port connectors directly to SAS drives, SATA II drives, or both. NOTE: The SAS i RAID controller is shown as an example. You can connect other SAS controllers with internal SAS port connectors in the same way. 1. Insert the SFF-8087 x4 internal mini SAS connector on the cable into a SFF-8087 x4 internal mini SAS connector on the SAS i RAID controller, as shown in Figure Plug the HDD connector on the other end of the internal cable into the connector on the SAS drive or the SATA II drive. 3. If you have another drive, connect it to another plug on the internal cable. You can connect other devices if the cable has more connectors. Page 24 June 2010
25 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 2: MegaRAID SAS Hardware Installation SAS Device Cables and Connectors Figure 7: Connecting the SAS i RAID Controller to a Drive HDD Connector Power Connector Connecting a SAS RAID Controller with External Connectors to a Drive Enclosure This section provides step-by-step instructions for connecting a SAS RAID controller with external SAS port connectors to a drive enclosure containing SAS drives, SATA II drives, or a combination of both drive types. Follow these steps to connect the cable from your controller to a drive enclosure. NOTE: The SAS e RAID controller is shown as an example. You can connect other SAS controllers with external SAS port connectors in the same way. 1. Connect the connector on one end of the cable to external port J1A4 or J1B1 on the SAS e RAID controller, as shown in Figure Connect the other end of the cable to the external port on the drive enclosure. June 2010 Page 25
26 Chapter 2: MegaRAID SAS Hardware Installation SAS Device Cables and Connectors MegaRAID 6Gb/s SAS RAID Controllers User Guide Figure 8: Connecting the SAS e RAID Controller to a Drive Enclosure To Drive Enclosure Mini SAS x4 Cable Plug Connector ibbu (Top View) LSI Rev. B Caution: Danger of explosion if battery is incorrectly replaced. Replace with same or equivalent type recommended by manufacturer. Dispose of used batteries according to manufacturer's instructions. WWYYN0000 ASSEMBLED IN USA e1 Pb Page 26 June 2010
27 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Chapter 3 MegaRAID SAS RAID Controller Characteristics This chapter describes the characteristics of the LSI MegaRAID Serial Attached SCSI/Serial ATA II 6Gb/s RAID controllers. Section 3.1, MegaRAID 6Gb/s SAS RAID Controller Family Section 3.2, MegaRAID SAS 6Gb/s RAID Controller Characteristics Section 3.3, Technical Specifications 3.1 MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID SAS 9240 RAID Controllers MegaRAID SAS 9240 RAID Controllers - Board Layout and Jumper/Connector Information The MegaRAID 6Gb/s SAS RAID controllers are dual PHY, SAS PCI Express RAID controllers and are used in a system with a PCI Express slot. PCI Express goes beyond the PCI specification in that it is intended as a unifying I/O architecture for various systems: desktops, workstations, mobile devices, servers, communications, and embedded devices. The following subsection provides graphics and connector information for the 6Gb/s SAS RAID controllers. The MegaRAID SAS i low-profile SAS/SATA II RAID controller controls four internal SAS/SATA ports through one SFF-8087 x4 internal mini SAS connector. The MegaRAID SAS i low-profile SAS/SATA II RAID controller controls eight internal SAS/SATA ports through two SFF-8087 x4 internal mini SAS connectors. This subsection provides the board layout, and the connector and jumper information for the SAS 9240 RAID controllers. Figure 9 shows the jumpers and the connectors on the SAS i RAID controller. NOTE: The SAS i RAID controller is like the SAS i RAID controller except that the SAS i does not contain the J5 connector, which supports ports 4 7. June 2010 Page 27
28 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide J2 J3 J4 J5 J Figure 9: Card Layout for the MegaRAID SAS i RAID Controller Table 3 describes the jumpers and the connectors on the SAS i and i RAID controllers. Table 3: SAS i and SAS i RAID Controllers Jumpers and Connectors Jumper Type Description J1 RISCwatch header 16-pin header Reserved for LSI use. J2 CPLD header 10-pin header Reserved for LSI use. J3 External LED drive activity/fault header 4-pin connector Connects to external, green or red LEDs that indicate drive activity or faults. J4 x4 SAS Ports 0 3 SFF-8087 x4 internal mini SAS connector Connects the cables from the controller to SAS drives or SATA II drives, or a SAS expander. J5 x4 SAS Ports 4 7 SFF-8087 x4 internal mini SAS connector Connects the cables from the controller to SAS drives or SATA II drives, or a SAS expander. NOTE: The SAS i RAID controller does not have the J5 connector. J6 TP1 U2 PCI Express x8 board edge connector Universal Asynchronous Receiver/Transmitter (UART) debugging MegaRAID RAID Key connector x8 interface that provides connections on both the top and the bottom of the board. 4-pin connector Reserved for LSI use. 2-pin connector To create a RAID 5 configuration, you have to plug a 1-wire key into this connector. Page 28 June 2010
29 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID SAS 9260 RAID Controllers MegaRAID SAS i, SAS i, and SAS 9260DE-8i RAID Controllers - Board Layout and Jumper/Connector Information The MegaRAID SAS i low-profile SAS/SATA II RAID controller controls four internal SAS/SATA ports through one SFF-8087 x4 internal mini SAS connector. The MegaRAID SAS i low-profile SAS/SATA II RAID controller controls eight internal SAS/SATA ports through two SFF-8087 x4 internal mini SAS connectors. The MegaRAID SAS 9260DE-8i low-profile SAS/SATA II RAID controller controls eight internal SAS/SATA ports through two SFF-8087 x4 internal mini SAS connectors and offers data security using disk encryption. The MegaRAID SAS i standard-height SAS/SATA II RAID controller controls 16 internal SAS/SATA ports through four SFF-8087 x4 internal mini SAS connectors. This subsection provides the board layout, and the connector and jumper information for the MegaRAID SAS i, SAS i, and SAS 9260DE-8i RAID controllers. Figure 10 shows the jumpers and the connectors on the SAS i RAID controller. NOTE: The SAS i RAID controller has the same connectors as the SAS i except for the JT7 connector, which supports ports 4 7. The SAS 9260DE-8i has the same connectors as the SAS i. JT2 JT12 JT13 JT10 JT7 Port JT9 7-4 JT11 JT8 JT6 Port 3-0 JT4 JT3 JT Figure 10: Card Layout for the MegaRAID SAS i RAID Controller NOTE: JT1, JT2, and JT4 are behind the LSIiBBU07 when the ibbu is installed, but they are still accessible. June 2010 Page 29
30 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 4 describes the jumpers and connectors on the SAS i, SAS i, and SAS 9260DE-8i RAID controllers. Table 4: SAS i, SAS i, and SAS 9260DE-8i RAID Controllers Jumpers and Connectors Jumper Type Description JT1 Write-pending Indicator (dirty cache) LED connector 2-pin connector Connects to an LED that indicates when the data in the cache has yet to be written to the storage devices. Used when the write-back feature is enabled. JT2 SAS Activity LED header 2-pin connector Connects to an LED that indicates drive activity. JT3 JT4 Battery Backup Unit connector Global Drive Fault LED header 20-pin connector Connects the intelligent Battery Backup Unit LSIiBBU07 to the RAID controller remotely. 2-pin connector Connects to a single LED to indicate whether any drive is in a fault condition. JT6 x4 SAS Ports 3 0 SFF-8087 x4 internal mini SAS connector Connects the cables from the RAID controller to SAS drives, SATA II drives, or a SAS expander. JT7 x4 SAS Ports 7 4 NOTE: The SAS i RAID controller does not have this connector. JT8 Modular RAID Key header 2-pin connector Reserved for LSI use. JT9 Set Factory Defaults connector SFF-8087 x4 internal mini SAS connector Connects the cables from the RAID controller to SAS drives, SATA II drives, or a SAS expander. 2-pin connector Reserved for LSI use. JT10 LSI Test header 2-pin connector Reserved for LSI use. Page 30 June 2010
31 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Table 4: SAS i, SAS i, and SAS 9260DE-8i RAID Controllers Jumpers and Connectors (Continued) Jumper Type Description JT11 JT12 IPMI-style SMBus (System Management)/I 2 C header Individual Drive Fault LED header for Eight Phys (0-7) 3-pin shielded header Provides enclosure management support. 16-pin connector Indicates drive faults. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the Unconfigured-Bad state. Refer to the MegaRAID SAS Software User s Guide for more information about drive states. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. JT13 Universal Asynchronous Receiver/Transmitter (UART) debugging NOTE: This header is used for RAID controllers with internal SAS ports only. 4-pin connector Reserved for LSI use MegaRAID SAS i RAID Controller - Board Layout and Jumper/Connector Information This subsection provides the board layout, and the connector and jumper information for the MegaRAID SAS i RAID controller. Figure 11 shows the jumpers and connectors on the SAS i controller. J1A2 J1B1 J2B1 Ports 0-3 J2B2 Ports 4-7 J3B1 Ports 8-11 J4B2 Ports J4A1 J4A3 J4A2 J5A2 J4A4 J5B3 J1L1 on back J1B3 J1C1 J2D Figure 11: Card Layout for the MegaRAID SAS i RAID Controller June 2010 Page 31
32 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide NOTE: Pin 1 on the headers and connectors is highlighted in black and red in Figure 11. Table 5 describes the jumpers and the connectors on the SAS i RAID controller. It includes diagrams showing Pin1 and their orientation for several of the connectors. Table 5: SAS i RAID Controller Connectors Jumper/ Connector J1A2 J1B1 Type Universal Asynchronous Receiver/ Transmitter (UART) for the Expander LED Locate and Fault Indication header Ports 0-3 Ports 4-7 PORT 0 +ve a -ve k Description 4-pin connector Reserved for LSI use. 2x8-pin connector Connects to an LED that indicates whether a drive is in a fault condition. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the unconfigured-bad state. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. NOTE: This header is used for RAID controllers with internal SAS ports only. PORT 7 J1B3 Premium Features Hardware Key header 2-pin header Enables support for selected premium features, which include recovery, CacheCade, FastPath, and SafeStore disk encryption. J1C1 IPMI-style I 2 C connector 3-pin connector Supports SES (SCSI enclosure services) over I 2 C through an internal I 2 C backplane cable. J1L1 J1B1 Remote Battery Backup connector (on the backside of the controller) 20-pin connector Connects the LSIiBBU07 intelligent Battery Backup Unit or the LSIiBBU08 intelligent Battery Backup Unit to the RAID controller remotely. Page 32 June 2010
33 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Table 5: SAS i RAID Controller Connectors (Continued) (Continued) Jumper/ Connector Type Description J2B1 x4 SAS Ports 0-3 internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J2B2 x4 SAS Ports 4-7 internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J2D1 Standard edge card connector The RAID controller interfaces with the host system though a standard edge card. This interface provides power to the board and an I 2 C interface connected to the I 2 C bus for IPMI. J3B1 x4 SAS Ports 8-11 internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J4A1 Module CPLD 1x8-pin connector Reserved for LSI use. J4A2 Activity LED header 2-pin connector Connects to an LED that indicates activity +ve a -ve k on the drives connected to the controller. J4A2 J4A3 Global drive fault LED header 2-pin connector Connects to an LED that indicates whether +ve -ve a drive is in a fault condition. a k J4A3 June 2010 Page 33
34 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 5: SAS i RAID Controller Connectors (Continued) (Continued) Jumper/ Connector J4A4 LED Locate and Fault Indication header Ports 8-11 Ports PORT 8 Type -ve k +ve a Description 2x8-pin header Connects to an LED that indicates whether a drive is in a fault condition. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the Unconfigured-Bad state. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. NOTE: This header is used for RAID controllers with internal SAS ports only. PORT 15 J4A4 J4B2 x4 SAS Ports internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J5A2 Write pending LED header 2-pin connector Connects to an LED that indicates when +ve a -ve k the data in the cache has yet to be written to the storage devices. Used when the write-back feature is enabled. J5B3 J5A2 Universal Asynchronous Receiver/Transmitter (UART) debugging 4-pin connector Reserved for LSI use MegaRAID SAS 9261 RAID Controller MegaRAID SAS i RAID Controller - Board Layout and Jumper/Connector Information The MegaRAID SAS i low-profile SAS/SATA II RAID controller controls eight internal SAS/SATA ports through two SFF-8087 mini-sas 4i connectors. This subsection provides the board layout, and the connector and jumper information for the SAS i RAID controller. Figure 12 shows the jumpers and connectors on the SAS i RAID controller. Page 34 June 2010
35 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Figure 12: Card Layout for the MegaRAID SAS i RAID Controller Table 6 describes the jumpers and connectors on the SAS i RAID controller. Table 6: SAS i RAID Controller Jumpers and Connectors Jumper Type Description J4L1 JT3B1 Remote Battery Backup Unit connector (on the rear of the controller) Battery Backup Unit connector JT5A1 x4 SAS Ports 0 3 Mini-SAS 4i connector JT5B1 x4 SAS Ports 4 7 Mini-SAS 4i connector JT5B2 Universal Asynchronous Receiver/Transmitter (UART) debugging JT5B3 Set Factory Defaults connector 20-pin connector Connects the LSIiBBU07 intelligent Battery Backup Unit to the RAID controller remotely. 20-pin connector Connects the LSIiBBU07 intelligent Battery Backup Unit directly to the RAID controller. Connects the cables from the RAID controller to SAS drives or SATA II drives, or a SAS expander. Connects the cables from the RAID controller to SAS drives or SATA II drives, or a SAS expander. 4-pin connector Reserved for LSI use. 2-pin connector Reserved for LSI use. JT6B1 Test header 2-pin connector Reserved for LSI use. JT6B2 Global Drive Fault LED header 2-pin connector Connects to an LED that indicates whether a drive is in a fault condition. JT6B3 SAS Activity LED header 2-pin connector Connects to an LED that indicates drive activity MegaRAID SAS 9280 RAID Controllers The MegaRAID SAS i4e low-profile SAS/SATA II RAID controller controls four internal SAS/SATA ports through one SFF-8087 x4 internal mini SAS connector and four external SAS/SATA ports through one SFF-8087 x4 external mini SAS connector. June 2010 Page 35
36 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide The MegaRAID SAS e low-profile SAS/SATA II RAID controller controls eight external SAS/SATA ports through two SFF-8088 x4 external mini SAS connectors. The MegaRAID SAS 9280DE-8e low-profile SAS/SATA II RAID controller controls eight external SAS/SATA ports through two SFF-8088 x4 external mini SAS connectors and offers data security using disk encryption. The MegaRAID SAS i4e standard-height SAS/SATA II RAID controller controls 16 internal SAS/SATA ports through four SFF-8087 x4 internal mini SAS connectors and four external SAS/SATA ports through one SFF-8087 x4 external mini SAS connector. The MegaRAID SAS i4e standard-height SAS/SATA II RAID controller controls 24 internal SAS/SATA ports through six SFF-8087 x4 internal mini SAS connectors and four external SAS/SATA ports through one SFF-8087 x4 external mini SAS connector MegaRAID SAS e and SAS 9280DE-8e RAID Controllers - Board Layout and Jumper/Connector Information This subsection provides the board layout and the connector information for the SAS 9280DE-8e and SAS e RAID controllers. Figure 13 shows the jumpers and the connectors on the SAS 9280DE-8e and SAS e RAID controllers. NOTE: The SAS 9280DE-8e has the same connectors as the SAS e. J1A4 Port 4-7 J1B1 Port 0-3 J1A2 J1A1 J1A3 J6A2 J6A1 J6A3 J6B1 J6B Figure 13: Card Layout for the MegaRAID SAS e RAID Controller NOTE: Connectors J6A1, J6A2, and J6A3 are behind the LSIiBBU07 when the ibbu is installed, but they are still accessible. Table 7 describes the jumpers and connectors on the SAS e RAID controller and the SAS 9280DE-8e RAID controller. Page 36 June 2010
37 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Table 7: SAS e and SAS 9280DE-8e RAID Controllers Connectors Connector Description Comments J1A1 Universal Asynchronous Receiver/Transmitter (UART) debugging 4-pin connector Reserved for LSI use. J1A2 Test header 2-pin connector Reserved for LSI use. J1A3 Set Factory Defaults connector 2-pin connector Reserved for LSI use. J1A4 x4 SAS Ports 4 7 SFF-8088 x4 external mini SAS connector Connects the cables from the controller to SAS drives or SATA II drives, or a SAS expander. J1B1 x4 SAS Ports 0 3 SFF-8088 x4 external mini SAS connector Connects the cables from the controller to SAS drives or SATA II drives, or a SAS expander. J6A1 Global Drive Fault LED header 2-pin connector Connects to an LED that indicates whether a drive is in a fault condition. J6A2 SAS Activity LED header 2-pin connector Connects to an LED that indicates drive activity. J6A3 J6B1 J6B2 Write-pending Indicator (dirty cache) LED connector Remote Battery Backup Unit connector Battery Backup Unit connector 2-pin connector Connects to an LED that indicates when the data in the cache has yet to be written to the storage devices. Used when the write-back feature is enabled. 20-pin connector Connects the intelligent Battery Backup Unit, LSIiBBU07, to the RAID controller remotely. 20-pin connector Connects the intelligent Battery Backup Unit, LSIiBBU07, directly to the RAID controller MegaRAID SAS i4e RAID Controller - Board Layout and Jumper/Connector Information This subsection provides the board layout and the connector information for the SAS i4e RAID controller. Figure 14 shows the jumpers and the connectors on the SAS i4e controller. June 2010 Page 37
38 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide J6A1 J6A2 J6A3 J1A4 J1A2 J1A3 J1A5 J1A1 J1B1 Port 7-4 J2B2 Port 3-0 J6B2 J6B Figure 14: Card Layout for the MegaRAID SAS i4e RAID Controller NOTE: Connectors J6A1, J6A2, and J6A3 are behind the LSIiBBU07 when the ibbu is installed, but they are still accessible. Table 8 describes the jumpers and the connectors on the SAS i4e RAID controller. Table 8: SAS i4e RAID Controller Connectors Connector Description Comments J1A1 Universal Asynchronous Receiver/Transmitter (UART) debugging 4-pin connector Reserved for LSI use. J1A2 LSI Test header 2-pin connector Reserved for LSI use. J1A3 J1A4 Set Factory Defaults connector IPMI-style I2C connector 2-pin connector Reserved for LSI use. 3-pin connector. Supports SES (SCSI Enclosure Services) over I 2 C over internal I 2 C backplane cable. J1A5 Modular RAID Key header 2-pin shielded header Enables support for RAID 5 configurations and self-encrypting disks (SED). J1B1 x4 SAS Ports 7 4 SFF-8088 x4 external mini SAS connector Connects the controller by cable to SAS drives or SATA II drives, or a SAS expander. J2B1 Standard edge card connector The RAID controller interfaces with the host system though a standard edge card x8 PCI-Express 2.0 bus connection as defined in the PCI-Express specification. This interface provides power to the board and to an I 2 C interface connected to I 2 C bus one for IPMI. J2B2 x4 SAS Ports 3-0 SFF-8087 x4 internal mini SAS connector Connects to an LED that indicates whether a drive is in a fault condition. Page 38 June 2010
39 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Table 8: SAS i4e RAID Controller Connectors (Continued) Connector Description Comments J6A1 J6A2 J6A3 J6B1 J6B2 Global Drive Fault LED header SAS Activity LED header Write-pending Indicator (dirty cache) LED connector Remote Battery Backup Unit connector Battery Backup Unit connector 2-pin connector Connects to an LED that indicates whether a drive is in a fault condition. 2-pin connector Connects to an LED that indicates drive activity. 2-pin connector Connects to an LED that indicates when the data in the cache has yet to be written to the storage devices. Used when the write-back feature is enabled. 20-pin connector Connects the LSIiBBU07 intelligent Battery Backup Unit to the RAID controller remotely. 20-pin connector Connects the LSIiBBU07 intelligent Battery Backup Unit to the RAID controller remotely. NOTE: Connectors J6A1, J6A2, and J6A3 are behind the LSIiBBU07 when the ibbu is installed, but they are still accessible MegaRAID SAS i4e and SAS i4e RAID Controllers - Board Layout and Jumper/Connector Information This subsection provides the board layout and the connector information for the SAS i4e RAID controller and the SAS i4e RAID controller. Figure 15 shows the jumpers and the connectors on the SAS i4e controller. June 2010 Page 39
40 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide J1A2 J1B1 J2B1 Ports 0-3 J2B2 Ports 4-7 J3B1 Ports 8-11 J4B2 Ports J4A1 J4A3 J4A2 J5A2 J4A5 J4A4 J5B3 J5A1 Ports J5B2 Ports J1L1 on back J1B3 J1B2 Ports J1C1 J2D Figure 15: Card Layout for the MegaRAID SAS i4e RAID Controller NOTE: Pin 1 on the headers and connectors is highlighted in black and red in Figure 15. NOTE: The SAS i4e RAID controller is like the SAS i4e RAID controller except that the SAS i4e does not contain the J4A5, J5A1, or J5B2 connectors. Page 40 June 2010
41 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Table 9 describes the jumpers and the connectors on the SAS i4e RAID controller. It includes diagrams showing Pin1 and their orientation for several of the connectors. Table 9: SAS i4e RAID Controller Connectors Jumper/ Connector J1A2 J1B1 Type Universal Asynchronous Receiver/ Transmitter (UART) for the Expander LED Locate and Fault Indication header Ports 0-3 Ports 4-7 PORT 0 +ve a -ve k Description 4-pin connector Reserved for LSI use. 2x8-pin connector Connects to an LED that indicates whether a drive is in a fault condition. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the unconfigured-bad state. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. NOTE: This header is used for RAID controllers with internal SAS ports only. PORT 7 J1B2 J1B3 x4 SAS Ports external connector Premium Features Hardware Key header SFF-8088 x4 external mini SAS connector Connects the controller by cable to a SAS/ SATA backplane or an expander. 2-pin header Enables support for selected premium features, which include recovery, CacheCade, FastPath, and SafeStore disk encryption. J1C1 IPMI-style I 2 C connector 3-pin connector Supports SES (SCSI enclosure services) over I 2 C through an internal I 2 C backplane cable. J1L1 J1B1 Remote Battery Backup connector (on the backside of the controller) 20-pin connector Connects the LSIiBBU07 intelligent Battery Backup Unit or the LSIiBBU08 intelligent Battery Backup Unit to the RAID controller remotely. June 2010 Page 41
42 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 9: SAS i4e RAID Controller Connectors (Continued) (Continued) Jumper/ Connector Type Description J2B1 x4 SAS Ports 0-3 internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J2B2 x4 SAS Ports 4-7 internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J2D1 Standard edge card connector The RAID controller interfaces with the host system though a standard edge card. This interface provides power to the board and an I 2 C interface connected to the I 2 C bus for IPMI. J3B1 x4 SAS Ports 8-11 internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J4A1 Module CPLD 1x8-pin connector Reserved for LSI use. J4A2 Activity LED header 2-pin connector Connects to an LED that indicates activity +ve a -ve k on the drives connected to the controller. J4A2 J4A3 Global drive fault LED header 2-pin connector Connects to an LED that indicates whether +ve -ve a drive is in a fault condition. a k J4A3 Page 42 June 2010
43 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controller Family Table 9: SAS i4e RAID Controller Connectors (Continued) (Continued) Jumper/ Connector J4A4 LED Locate and Fault Indication header Ports 8-11 Ports PORT 8 Type -ve k +ve a Description 2x8-pin header Connects to an LED that indicates whether a drive is in a fault condition. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the Unconfigured-Bad state. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. NOTE: This header is used for RAID controllers with internal SAS ports only. J4A5 PORT 15 J4A4 LED Locate and Fault Indication header Ports Ports PORT 16 -ve k +ve a 2x8-pin header Connects to an LED that indicates whether a drive is in a fault condition. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the unconfigured-bad state. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port. NOTE: This header is used for RAID controllers with internal SAS ports only. PORT 23 J4A5 June 2010 Page 43
44 Chapter 3: MegaRAID SAS RAID Controller Characteristics MegaRAID SAS 6Gb/s RAID Controller Characteristics MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 9: SAS i4e RAID Controller Connectors (Continued) (Continued) Jumper/ Connector Type Description J4B2 x4 SAS Ports internal connector J5A1 x4 SAS Ports internal connector SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. J5A2 Write pending LED header 2-pin connector Connects to an LED that indicates when +ve a -ve k the data in the cache has yet to be written to the storage devices. Used when the write-back feature is enabled. J5B2 x4 SAS Ports internal connector J5B3 J5A2 Universal Asynchronous Receiver/Transmitter (UART) debugging SFF-8087 x4 internal mini SAS connector Connects the controller by cable to SAS drives or SATA 2 drives. 4-pin connector Reserved for LSI use. 3.2 MegaRAID SAS 6Gb/s RAID Controller Characteristics Table 10 shows the general characteristics for all MegaRAID 6Gb/s SAS RAID controllers. Table 10: MegaRAID 6Gb/s SAS RAID Controller Characteristics Flash ROM a Serial EEPROM b a.for boot code and firmware. b.for BIOS configuration storage. Data Transfer Rates Yes Yes Up to 6Gb/s per port for SAS and up to 3Gb/s per port for SATA II SCSI Features Plug and Play Scatter/Gather Activity LED SCSI Termination Active Each MegaRAID 6Gb/s SAS RAID controller ensures data integrity by intelligently validating the compatibility of the SAS domain. The MegaRAID 6Gb/s SAS RAID controllers use Fusion-MPT architecture, which allows for thinner drivers and better performance. 3.3 Technical Specifications The design and implementation of the MegaRAID 6Gb/s SAS RAID controllers minimize electromagnetic emissions, susceptibility to radio frequency energy, and the effects of electrostatic discharge. The MegaRAID 6Gb/s SAS RAID controllers show the following marks and certifications: Page 44 June 2010
45 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications CE mark C-Tick mark FCC Self-Certification logo Canadian Compliance Statement Korean MIC Taiwan BSMI Japan VCCI CISPR Class B The following hardware is compliant with CSA C22.2 No , UL First Edition-listed accessory, UL file number E257743: MegaRAID SAS i RAID controller (model 25083) MegaRAID SAS i RAID controller (model 25091) MegaRAID SAS i RAID controller (model A) MegaRAID SAS i RAID controller (model ) MegaRAID SAS 9260DE-8i RAID controller (model 25121) MegaRAID SAS i RAID controller (model L ) MegaRAID SAS i RAID controller (model 25239) MegaRAID SAS i4e RAID controller (model 25305) MegaRAID SAS e RAID controller (model 25152) MegaRAID SAS 9280DE-8e RAID controller (model 25152) MegaRAID SAS i4e RAID controller (model L ) MegaRAID SAS i4e RAID controller (model L ) LSI intelligent battery backup unit 07 (model 25034) LSI intelligent battery backup unit 08 (model 25343) RAID Controller Specifications Table 11 lists the specifications for the MegaRAID 6Gb/s SAS RAID controllers. June 2010 Page 45
46 Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 11: RAID Controller Specifications Specification Processor (PCI Express host controller to PCI secondary I/O controller) MegaRAID SAS 9240, SAS 9260, SAS 9261, and SAS 9280 RAID Controllers SAS LSISAS2008 PCI Express-SAS/SATA I/O Processor chip SAS 9260, SAS 9261, and SAS LSISAS2108 ROC device with Integrated PowerPC processor Part number SAS i RAID controller: SAS i RAID controller: SAS i RAID controller: SAS i RAID controller: SAS 9260DE-8i RAID controller: SAS i RAID controller: L SAS i RAID controller (model 25239) SAS i4e RAID controller: SAS e RAID controller: SAS 9280DE-8e RAID controller: SAS i4e RAID controller: L SAS i4e RAID controller: L LSIiBBU07 intelligent Battery Backup Unit: LSIiBBU08 intelligent Battery Backup Unit: Operating voltage +3.3 V, +12 V Card size SAS i RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS i RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS i RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS i RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS 9260DE-8i RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS i RAID controller: Standard-height PCI Express adapter card size ( mm x mm) SAS i RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS i4e RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS e RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS 9280DE-8e RAID controller: Low-profile PCI Express adapter card size ( mm x mm) SAS i4e RAID controller: Standard-height PCI Express adapter card size ( mm x mm) SAS i4e RAID controller: Standard-height PCI Express adapter card size ( mm x mm) Array interface to the host PCI Express Rev. 2.0 Page 46 June 2010
47 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications Table 11: RAID Controller Specifications (Continued) PCI Express bus data transfer rate Serial port SAS controller Specification SAS bus speed SAS ports Cache configuration Size of flash ROM for firmware Nonvolatile random access memory (NVRAM) MegaRAID SAS 9240, SAS 9260, SAS 9261, and SAS 9280 RAID Controllers Up to 5 Gb/s per lane x8 lane width 4-pin RS232-compatible connector (for manufacturing use only) LSISAS2108 Single SAS controller LSISAS2008 PCI Express-SAS/SATA I/O Processor chip 6Gb/s SAS connectors with four SAS ports each The RAID controllers support the following battery-backed cache configuration: 512 MB 72b arrangement (5) 64Mx16, Double Data Rate II 800 MHz battery-backed module 8 MB 32 KB for storing RAID configurations Array Performance Features Table 12 shows the array performance features for the MegaRAID 6Gb/s SAS RAID controllers. Table 12: Array Performance Features Specification MegaRAID SAS 9240, SAS 9260, SAS 9261, and SAS 9280 RAID Controllers PCI Express host data transfer rate 5Gb/s per lane Drive data transfer rate 6Gb/s per lane Maximum scatter/gather I/O 80 elements Maximum size of I/O requests 6.4 MB in 64-KB stripes Maximum queue tags per drive As many as the drive can accept Stripe sizes 8 KB, 16 KB, 32 KB, 64 KB, 128 KB, 256 KB, 512 KB, or 1 MB Maximum number of concurrent commands Fault Tolerance Table 13 lists the fault tolerance features for the MegaRAID 6Gb/s SAS RAID controllers. June 2010 Page 47
48 Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications MegaRAID 6Gb/s SAS RAID Controllers User Guide Table 13: Fault Tolerance Features Specification Support for SMART a Drive failure detection Drive rebuild using hot spares Parity generation and checking Yes MegaRAID SAS 9240, SAS 9260, SAS 9261, and SAS 9280 RAID Controllers Automatic Automatic Yes a. The Self Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all predictable drive failures. In addition, SMART monitors the internal performance of all motors, heads, and drive electronics Electrical Characteristics This subsection provides the power supply requirements for the MegaRAID 6Gb/s SAS RAID controllers Power Supply Requirements for SAS 9240 RAID Controllers All power is supplied to the SAS 9240 RAID controllers through the PCI Express 3.3V rails and the 12V rail. Onboard switching regulator circuitry operating from the 3.3V rails and the 12V rail provide the necessary voltages. The following states determine the typical current consumption of the controller: State 1: During a hard reset State 2: During a drive stress test State 3: While sitting idle at the DOS prompt The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 14 lists the power supply for the RAID controllers for each of the three states at the different voltages. Table 14: Power Supply for SAS 9240 RAID Controllers PCI Edge Connector State 1 State 2 State 3 3.3V supply 330mA 330mA 330mA +12V supply 1.00A 1.81A 1.53A 3.3V auxiliary supply 30mA 30mA 30mA Operating and Non-operating Conditions for the SAS 9240 RAID Controllers For the SAS 9240 RAID controllers, the operating (thermal and atmospheric) conditions are: Relative humidity range is 20 percent to 80 percent noncondensing. Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2008 processor above the maximum ambient temperature. Temperature range: +10 C to +60 C. The parameters for the non-operating (such as storage and transit) environment for these controllers are: Relative humidity range is 5 percent to 90 percent noncondensing. Page 48 June 2010
49 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications Temperature range: 30 C to +80 C Power Supply Requirements for MegaRAID SAS i, SAS i, and SAS 9260DE-8i RAID Controllers All power is supplied to the MegaRAID SAS i, SAS i, and SAS 9260DE-8i RAID controllers through the PCI Express 3.3V rails and the 12V rail. Onboard switching regulator circuitry operating from the 3.3V rails and the 12V rail provide the necessary voltages. The following states determine the typical current consumption of the controller: State 1: During a hard reset State 2: During a drive stress test State 3: While sitting idle at the DOS prompt The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 15 lists the power supply for the RAID controllers for each of the three states at the different voltages. Table 15: Power Supply for SAS 9260 RAID Controllers PCI Edge Connector State 1 State 2 State 3 3.3V supply 330mA 330mA 330mA +12V supply 1.00A 1.81A 1.53A 3.3V auxiliary supply 30mA 30mA 30mA NOTE: +12V is used in the charging circuitry for the battery pack on the optional ibbu battery-backed daughter card. If the BBU daughter card is mounted, the following power consumption figures apply: During trickle charging of the battery pack: N/A (no trickle charge for Li-ION). During fast charging of the battery pack: 230mA in +12V current Operating and Non-operating Conditions for MegaRAID SAS i, SAS i, and SAS 9260DE-8i RAID Controllers For the MegaRAID SAS i, SAS i, and SAS 9260DE-8i RAID controllers, the operating (thermal and atmospheric) conditions are: Relative humidity range is 5 percent to 90 percent noncondensing (20 percent to 80 percent noncondensing for the RAID controllers) Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2108 processor above the maximum ambient temperature Temperature range: +10 C to +60 C without battery backup unit Temperature range: +10 C to C with ibbu battery backup The parameters for the non-operating (such as storage and transit) environment for these controllers are: Temperature range: 30 C to +80 C without the battery backup unit Temperature range: 0 C to +45 C with the battery backup unit June 2010 Page 49
50 Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications MegaRAID 6Gb/s SAS RAID Controllers User Guide Power Supply Requirements for the SAS i RAID Controller All power is supplied to the SAS i RAID controller through the PCI Express 3.3V rails and the 12V rail. Onboard switching regulator circuitry operating from the 3.3V rails and the 12V rail provide the necessary voltages. The following states determine the typical current consumption of the controller: State 1: During a consistency checks of all RAID 5 virtual drives at one time State 2: While sitting idle at the DOS prompt State 3: During a RAID 5 stress test State 4: During a drive stress test while the BBU is under fast charging The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 16 lists the power supply for the controller for each of the three states at the different voltages. Table 16: Power Supply for the SAS i RAID Controller PCI Edge Connector State 1 State 2 State 3 State 4 3.3V supply 1.339A 1.174A 1.225A 1.356A +12V supply 1.466A 1.426A 1.487A 1.773A 3.3V auxiliary supply 0.048A 0.026A 0.214A 0.168A Total Power W W W W NOTE: +12V is used in the charging circuitry for the battery pack on the optional ibbu battery-backed daughter card. If the ibbu daughter card is mounted, refer to State 4 in Table 16 for typical current consumption values Operating and Non-operating Conditions for the SAS i RAID Controller The operating (thermal and atmospheric) conditions for the SAS i RAID controller are: Relative humidity range is 20 percent to 80 percent noncondensing. Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2108 processor above the maximum ambient temperature. Operating ambient temperature: +55 C (The ibbu is not included in the limit as it is present remotely in the system. You need to make sure that maximum operating ambient temperature around the ibbu07 is 45 C and 55 C for the ibbu08). NOTE: The operating ambient temperature of these RAID controllers can be raised to +60 C, provided the airflow over the controller is at least 300 LFPM. The parameter for the non-operating (such as storage and transit) environment for the controller is: Temperature range: 30 C to +80 C without the battery backup unit Temperature range: 0 C to +45 C with the ibbu07 battery backup unit and 0 C to +55 C with the ibbu08 battery backup unit Page 50 June 2010
51 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications Power Supply Requirements for the SAS 9261 RAID Controller All power is supplied to the SAS 9261 RAID controller through the PCI Express 3.3V rails and the 12V rail. Onboard switching regulator circuitry operating from the 3.3V rails and the 12V rail provide the necessary voltages. The following states determine the typical current consumption of the controller: State 1: During a hard reset State 2: During a drive stress test State 3: While sitting idle at the DOS prompt The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 17 lists the power supply for the RAID controller for each of the three states at the different voltages. Table 17: Power Supply for SAS 9261 RAID Controllers PCI Edge Connector State 1 State 2 State 3 3.3V supply 330mA 330mA 330mA +12V supply 1.00A 1.81A 1.53A 3.3V auxiliary supply 30mA 30mA 30mA NOTE: +12V is used in the charging circuitry for the battery pack on the optional ibbu battery-backed daughter card. If the BBU daughter card is mounted, the following power consumption figures apply: During trickle charging of the battery pack: N/A (no trickle charge for Li-ION). During fast charging of the battery pack: 230mA in +12V current Operating and Non-operating Conditions for the SAS 9261 RAID Controller For the SAS 9261 RAID controllers, the operating (thermal and atmospheric) conditions are: Relative humidity range is 5 percent to 90 percent noncondensing (20 percent to 80 percent noncondensing for the RAID controllers) Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2108 processor above the maximum ambient temperature Temperature range: +10 C to +60 C without battery backup unit Temperature range: +10 C to C with ibbu battery backup The parameters for the non-operating (such as storage and transit) environment for these controllers are: Temperature range: 30 C to +80 C without the battery backup unit Temperature range: 0 C to +45 C with the battery backup unit Power Supply Requirements for SAS i4e, SAS e, and SAS 9280DE-8e RAID Controllers All power is supplied to the SAS i4e, SAS e, and SAS 9280DE-8e RAID controllers through the PCI Express 3.3V rails and the 12V rail. Onboard switching regulator circuitry operating from the 3.3V rails and the 12V rail provide the necessary voltages. The following states determine the typical current consumption of the controller: State 1: During a hard reset June 2010 Page 51
52 Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications MegaRAID 6Gb/s SAS RAID Controllers User Guide State 2: During a disk stress test State 3: While sitting idle at the DOS prompt The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 18 lists the power supply for the controller for each of the three states at the different voltages. Table 18: Power Supply for SAS i4e, SAS e, and SAS 9280DE-8e RAID Controllers PCI Edge Connector State 1 State 2 State 3 3.3V supply 330mA 330mA 330mA +12V supply 1.00A 1.81A 1.53A 3.3V auxiliary supply 30mA 30mA 30mA NOTE: +12V is used in the charging circuitry for the battery pack on the optional ibbu battery-backed daughter card. If the ibbu daughter card is mounted, the following power consumption figures apply: During fast charging of the battery pack: 230mA in +12V current Operating and Non-operating Conditions for SAS i4e, SAS e, and SAS 9280DE-8e RAID Controllers The operating (thermal and atmospheric) conditions for the SAS i4e, SAS e, and SAS 9280DE-8e RAID controllers are: Relative humidity range is 5% to 90% noncondensing. Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2108 processor above the maximum ambient temperature. Temperature range: +10 C to +60 C without battery backup unit. Temperature range: +10 C to C with ibbu battery backup. The parameters for the non-operating (such as storage and transit) environment for the controller are: Temperature range: 30 C to +80 C without battery backup unit. Temperature range: 0 C to +45 C with ibbu battery backup Power Supply Requirements for the SAS i4e and SAS i4e RAID Controllers All power is supplied to the SAS i4e RAID controller and the SAS i4e RAID controller through the PCI Express 3.3V rails and the 12V rail. Onboard switching regulator circuitry operating from the 3.3V rails and the 12V rail provide the necessary voltages. The following states determine the typical current consumption of the controller: State 1: During a consistency checks of all RAID 5 virtual drives at one time State 2: While sitting idle at the DOS prompt State 3: During a RAID 5 stress test State 4: During a drive stress test while the BBU is under fast charging Page 52 June 2010
53 MegaRAID 6Gb/s SAS RAID Controllers User Guide Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9 percent (from PCI edge connector only). Table 19 lists the power supply for the controller for each of the three states at the different voltages. Table 19: Power Supply for the SAS i4e RAID Controller and the SAS i4e RAID Controller PCI Edge Connector State 1 State 2 State 3 State 4 3.3V supply 1.339A 1.174A 1.225A 1.356A +12V supply 1.466A 1.426A 1.487A 1.773A 3.3V auxiliary supply 0.048A 0.026A 0.214A 0.168A Total Power W W W W NOTE: +12V is used in the charging circuitry for the battery pack on the optional ibbu battery-backed daughter card. If the ibbu daughter card is mounted, refer to State 4 in Table 19 for typical current consumption values Operating and Non-operating Conditions for the SAS i4e RAID Controller and the SAS i4e RAID Controllers The operating (thermal and atmospheric) conditions for the SAS i4e RAID controller and the SAS i4e RAID controller are: Relative humidity range is 20% to 80% noncondensing. Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the LSISAS2108 processor above the maximum ambient temperature. Operating ambient temperature: +55 C (The ibbu is not included in the limit as it is present remotely in the system. You need to make sure that maximum operating ambient temperature around the ibbu07 is 45 C and 55 C for the ibbu08). NOTE: The operating ambient temperature of these RAID controllers can be raised to +60 C, provided the airflow over the controller is at least 300 LFPM. The parameter for the non-operating (such as storage and transit) environment for the controller is: Temperature range: 30 C to +80 C without the battery backup unit Temperature range: 0 C to +45 C with the ibbu07 battery backup unit and 0 C to +55 C with the ibbu08 battery backup unit Safety Characteristics All MegaRAID 6Gb/s SAS RAID controllers meet or exceed the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier name or trademark, type, and UL flammability rating. For the boards installed in a PCI Express bus slot, all voltages are lower than the SELV 42.4V limit. June 2010 Page 53
54 Chapter 3: MegaRAID SAS RAID Controller Characteristics Technical Specifications MegaRAID 6Gb/s SAS RAID Controllers User Guide Page 54 June 2010
55 MegaRAID 6Gb/s SAS RAID Controllers User Guide Appendix A: Glossary of Terms and Abbreviations Appendix A Glossary of Terms and Abbreviations This appendix lists terms and abbreviations that are used in this user guide. BIOS. Acronym for Basic Input/Output System. Software that provides basic read/write capability. Usually kept as firmware (ROM-based). The system BIOS on the motherboard of a computer boots and controls the system. The BIOS on your host adapter acts as an extension of the system BIOS. configuration. Refers to the way a computer is set up, the combined hardware components (computer, monitor, keyboard, and peripheral devices) that make up a computer system, or the software settings that allow the hardware components to communicate with each other. device driver. A program that allows a microprocessor (through the operating system) to direct the operation of a peripheral device. domain validation. A software procedure in which a host queries a device to determine its ability to communicate at the negotiated data rate. drive group. A group of physical drives that combines the storage space on the drives into a single segment of storage space. A hot spare drive does not actively participate in a drive group. EEPROM. Acronym for Electronically Erasable Programmable Read-Only Memory. It is a memory chip that typically stores configuration information, as it provides stable storage for long periods without electricity and can be reprogrammed. See NVRAM. external SAS device. A SAS device installed outside the computer cabinet. These devices are connected using specific types of shielded cables. Fusion-MPT architecture. An acronym for Fusion-Message Passing Technology architecture. Fusion-MPT consists of several main elements: Fusion-MPT firmware, the Fibre Channel and SCSI hardware, and the operating system level drivers that support these architectures. Fusion-MPT architecture offers a single binary, operating system driver that supports both Fibre Channel and SCSI devices. host. The computer system in which a RAID controller is installed. It uses the RAID controller to transfer information to and from devices attached to the SCSI bus. host adapter board. A circuit board or integrated circuit that provides a device connection to the computer system. June 2010 Page 55
56 Appendix A: Glossary of Terms and Abbreviations MegaRAID 6Gb/s SAS RAID Controllers User Guide hot spare. An idle, powered on, standby drive that is ready for immediate use in case of drive failure. A hot spare does not contain any user data. A hot spare can be dedicated to a single redundant array or it can be part of the global hot-spare pool for all arrays managed by the controller. When a drive fails, the controller firmware automatically replaces and rebuilds the data from the failed drive to the hot spare. Data can be rebuilt only from virtual drives with redundancy (RAID levels 1, 5, 6, 10, 50, and 60; not RAID level 0), and the hot spare must have sufficient capacity. internal SAS device. A SAS device installed inside the computer cabinet. These devices are connected by using a shielded cable. main memory. The part of computer memory that is directly accessible by the CPU (usually synonymous with RAM). NVRAM. Acronym for nonvolatile random access memory. An EEPROM (electronically erasable read-only memory) chip that stores configuration information. See EEPROM. PCI. Acronym for peripheral component interconnect. A high-performance, local bus specification that allows the connection of devices directly to computer memory. The PCI Local Bus allows transparent upgrades from 32-bit data path at 33 MHz to 64-bit data path at 33 MHz, and from 32-bit data path at 66 MHz to 64-bit data path at 66 MHz. PCI Express. Acronym for peripheral component interconnect Express. A highperformance, local bus specification that allows the connection of devices directly to computer memory. PCI Express is a two-way, serial connection that transfers data on two pairs of point-to-point data lines. PCI Express goes beyond the PCI specification in that it is intended as a unifying I/O architecture for various systems: desktops, workstations, mobile, server, communications, and embedded devices. peripheral devices. A piece of hardware (such as a video monitor, drive, printer, or CD-ROM) used with a computer and under the control of the computer. SCSI peripherals are controlled through a SAS MegaRAID SAS RAID controller (host adapter). PHY. The interface required to transmit and receive data packets transferred across the serial bus. Each PHY can form one side of the physical link in a connection with a PHY on a different SATA device. The physical link contains four wires that form two differential signal pairs. One differential pair transmits signals, while the other differential pair receives signals. Both differential pairs operate simultaneously and allow concurrent data transmission in both the receive and the transmit directions. RAID. Acronym for Redundant Array of Independent Disks (originally Redundant Array of Inexpensive Disks). An array (group) of multiple independent drives managed together to yield higher reliability, performance, or both exceeding that of a single drive. The RAID array appears to the controller as a single storage unit. I/O is expedited because several drives can be accessed simultaneously. Redundant RAID levels (RAID levels 1, 5, 6, 10, 50, and 60) provide data protection. Page 56 June 2010
57 MegaRAID 6Gb/s SAS RAID Controllers User Guide Appendix A: Glossary of Terms and Abbreviations RAID levels. A set of techniques applied to drive groups to deliver higher data availability, performance characteristics, or both to host environments. Each virtual drive must have a RAID level assigned to it. SAS. Acronym for Serial Attached SCSI. A serial, point-to-point, enterprise-level device interface that leverages the proven SCSI protocol set. The SAS interface provides improved performance, simplified cabling, smaller connections, lower pin count, and lower power requirements when compared to parallel SCSI. SAS controllers leverage a common electrical and physical connection interface that is compatible with Serial ATA. The SAS controllers support the ANSI Serial Attached SCSI Standard, Version 2.0. In addition, the controller supports the Serial ATA II (SATA II) protocol defined by the Serial ATA Specification, Version 1.0a. Supporting both the SAS interface and the SATA II interface, the SAS controller is a versatile controller that provides the backbone of both server and high-end workstation environments. Each port on the SAS RAID controller supports SAS devices, SATA II devices, or both. SAS device. Any device that conforms to the SAS standard and is attached to the SAS bus by a SAS cable. This includes SAS RAID controllers (host adapters) and SAS peripherals. SATA. Acronym for Serial Advanced Technology Attachment. A physical storage interface standard, SATA is a serial link that provides point-to-point connections between devices. The thinner serial cables allow for better airflow within the system and permit smaller chassis designs. SMP. Acronym for Serial Management Protocol. SMP communicates topology management information directly with an attached SAS expander device. Each PHY on the controller can function as an SMP initiator. SSP. Acronym for Serial SCSI Protocol. SSP enables communication with other SAS devices. Each PHY on the SAS controller can function as an SSP initiator or SSP target. STP. Acronym for Serial Tunneling Protocol. STP enables communication with a SATA II device through an attached expander. Each PHY on the SAS controller can function as an STP initiator. strip. The portion of a stripe that resides on a single drive. stripe size. The total drive space consumed by a stripe not including a parity drive. For example, consider a stripe that contains 64 KB of drive space and has 16 KB of data residing on each drive in the stripe. In this case, the stripe size is 64 KB and the strip is 16 KB. The stripe depth is four (four drives in the stripe). You can specify stripe sizes of 8 KB, 16 KB, 32 KB, 64 KB, 128 KB, 256 KB, 512 KB, or 1 MB for each virtual drive. A larger stripe size produces improved read performance, especially if most of the reads are sequential. For mostly random reads, select a smaller stripe size. June 2010 Page 57
58 Appendix A: Glossary of Terms and Abbreviations MegaRAID 6Gb/s SAS RAID Controllers User Guide striping. Drive striping writes data across two or more drives. Each stripe spans two or more drives but consumes only a portion of each drive. Each drive, therefore, may have several stripes. The amount of space consumed by a stripe is the same on each drive that is included in the stripe. The portion of a stripe that resides on a single drive is a stripe element. Striping by itself does not provide data redundancy; striping in combination with parity provides data redundancy. Page 58 June 2010
59 MegaRAID 6Gb/s SAS RAID Controllers User Guide Appendix B: Customer Feedback Reader s Comments Appendix B Customer Feedback This appendix provides a form you can fill out to help us improve our documentation. We would appreciate your feedback on this document. Please copy the following page, add your comments, and fax it to us at the number shown. If appropriate, please also fax copies of any marked-up pages from this document. NOTE: Please include your name, phone number, fax number, and company address so that we can contact you directly for clarification or additional information. Thank you for your help in improving the quality of our documents. B.1 Reader s Comments Fax your comments to: LSI Corporation Technical Publications M/S E-198 Fax: Please tell us how you rate this document: MegaRAID 6Gb/s SAS RAID Controllers User Guide. Place a check mark in the appropriate blank for each category. Excellent Good Average Fair Poor Completeness of information Clarity of information Ease of finding information Technical content Usefulness of examples and illustrations Overall manual What could we do to improve this document? June 2010 Page 59
60 Appendix B: Customer Feedback Reader s Comments MegaRAID 6Gb/s SAS RAID Controllers User Guide If you found errors in this document, please specify the error and page number. If appropriate, please fax a marked-up copy of the page(s). Please complete the information below so that we may contact you directly for clarification or additional information Name Date Telephone Fax Title Department Mail Stop Company Name Street City, State, Zip Page 60 June 2010
61
62
6Gb/s MegaRAID SAS RAID Controllers
6Gb/s MegaRAID SAS RAID Controllers User Guide 41450-04, Rev. B 41450-04B Revision History Version and Date Description of Changes 41450-04, Rev. B, Updated the environmental conditions for the RAID controllers.
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
12Gb/s Intel RAID Controllers User Guide. Intel Order Number: H21668-003
12Gb/s Intel RAID Controllers User Guide Intel Order Number: H21668-003 DISCLAIMER IINFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL
USER S GUIDE. MegaRAID SAS Software. March 2009. 80-00156-01 Rev. F
USER S GUIDE MegaRAID SAS Software March 2009 80-00156-01 Rev. F This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or disclosed to
Intel RAID Controller SASMF8I Hardware User s Guide. Intel Order Number: E33625-003
Intel RAID Controller SASMF8I Hardware User s Guide Intel Order Number: E33625-003 DISCLAIMER INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R) PROD- UCTS. NO LICENSE, EXPRESS OR IMPLIED,
MegaRaid SAS Software
MegaRaid SAS Software User Guide 80-00156-01 Rev. I June 2010 80-00156- 01I Revision History Version and Date Description of Changes 80-00156-01 Rev. I, June 2010 Updated the document with changes to the
ServeRAID-MR Software
USER S GUIDE ServeRAID-MR Software February 2009 IBM P/N: 46M1381 Third Edition (February 2009) Copyright International Business Machines Corporation 2008. All rights reserved. US Government Users Restricted
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide
PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters User Guide September 2010 Revision History Version and Date September 2010 April 2010 March 2010 October 2009 July 2009 Description of
HARDWARE GUIDE. MegaRAID SCSI 320-2 RAID Controller
HARDWARE GUIDE MegaRAID SCSI 320-2 RAID Controller November 2002 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed
HARDWARE GUIDE. MegaRAID SCSI 320-0 Zero-Channel RAID Controller
HARDWARE GUIDE MegaRAID SCSI 320-0 Zero-Channel RAID Controller September 2002 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used
HARDWARE GUIDE. MegaRAID SCSI 320-1 RAID Controller
HARDWARE GUIDE MegaRAID SCSI 320-1 RAID Controller September 2002 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed
Intel Order Number: E33256-001. Intel RAID Controller SRCSASPH16I Hardware Guide
Intel RAID Controller SRCSASPH16I Hardware Guide Intel Order Number: E33256-001 Intel RAID Controller SRCSASPH16I Hardware Guide i INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R) PROD-
MegaRAID Configuration Software
USER S GUIDE MegaRAID Configuration Software March 2006 DB15-000269-01 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card User Manual Model: UGT-ST644R All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction...
QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview
Overview The HP Smart Array E200 is HP's first entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The full size card has 8 ports and utilizes DDR1-266 memory. The E200 is ideal
PCIe SATA 6G Raid Card
PCIe SATA 6G Raid Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...
Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00
Education Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller Study guide XW5078 Release 1.00 May 2006 Servicing the IBM ServeRAID-8k Serial- Attached SCSI (SAS) Controller Overview The ServeRAID
MegaRAID SAS Device Driver Installation
MegaRAID SAS Device Driver Installation User Guide 80-00163-01, Rev. G Revision History Version and Date Description of Changes 80-00163-01 Rev. G, Added the Microsoft Windows 8 operating system (OS),
User Guide - English. Embedded MegaRAID Software
User Guide - English Embedded MegaRAID Software April 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering
DELL RAID PRIMER DELL PERC RAID CONTROLLERS Joe H. Trickey III Dell Storage RAID Product Marketing John Seward Dell Storage RAID Engineering http://www.dell.com/content/topics/topic.aspx/global/products/pvaul/top
ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide
ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for IBM System x are the next-generation 6 Gbps SAS
As enterprise data requirements continue
Storage Introducing the Dell PERC 6 Family of SAS RAID ControlLers By Bhanu Prakash Dixit Sanjay Tiwari Kedar Vaze Joe H. Trickey III The Dell PowerEdge Expandable RAID Controller (PERC) 6 family of enterprise-class
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit
MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide 49760-00, Revision A January 2011 49760-00A Revision History Version and Date 49760-00 Rev. A, January 2011 Initial release of
Dell PowerEdge RAID Controller Cards H700 and H800 Technical Guide
PowerEdge RAID Controller Cards H700 and H800 Technical Guide Enterprise-class controllers designed for performance, reliability, and fault tolerance. This document is for informational purposes only.
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to
MegaRAID LSIiBBU08 Intelligent Battery Backup Unit. Quick Installation Guide
MegaRAID LSIiBBU08 Intelligent Battery Backup Unit Quick Installation Guide 46307-00, Revision A, August 2010 Revision History Version and Date 46307-00, August 2010 Initial release of document. Description
Serial Attached SCSI RAID Controllers Installation and User s Guide
Serial Attached SCSI RAID Controllers Installation and User s Guide 2 Copyright 2008 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
USER S GUIDE. MegaRAID SAS Software. June 2007 Version 2.0. 80-00156-01, Rev. B
USER S GUIDE MegaRAID SAS Software June 2007 Version 2.0 80-00156-01, Rev. B This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or
This chapter explains how to update device drivers and apply hotfix.
MegaRAID SAS User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an overview
DataCenter 7280 3Gb/s SATA Host Adapter User Manual
DataCenter 7280 3Gb/s SATA Host Adapter User Manual Revision: 1.1 Date: May 2011 HighPoint Technologies, Inc. Copyright... 3 Trademarks... 3 HighPoint Technologies, Inc.... 4 Highpoint DataCenter 7280
WebBIOS Configuration Utility Guide
Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC WebBIOS Configuration Utility Guide www.dell.com support.dell.com Information in this document is subject to change without notice.
The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.
SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled
RAID EzAssist Configuration Utility Quick Configuration Guide
RAID EzAssist Configuration Utility Quick Configuration Guide DB15-000277-00 First Edition 08P5520 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The
Intel RAID Software User s Guide:
Intel RAID Software User s Guide: Intel Embedded Server RAID Technology II Intel Integrated Server RAID Intel RAID Controllers using the Intel RAID Software Stack 3 Revision 9.0 December, 2008 Intel Order
Intel RAID Controllers
Intel RAID Controllers Best Practices White Paper April, 2008 Enterprise Platforms and Services Division - Marketing Revision History Date Revision Number April, 2008 1.0 Initial release. Modifications
USER S GUIDE. MegaRAID SAS Software. April 2008. 80-00156-01, Rev. D
USER S GUIDE MegaRAID SAS Software April 2008 80-00156-01, Rev. D This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by or disclosed to
TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS
TECHNOLOGY BRIEF August 1999 Compaq Computer Corporation Prepared by ISSD Technology Communications CONTENTS Executive Summary 1 Introduction 3 Subsystem Technology 3 Processor 3 SCSI Chip4 PCI Bridge
Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers
Overview The SA6400A is a high-performance Ultra320, PCI-X array controller. It provides maximum performance, flexibility, and reliable data protection for HP OpenVMS AlphaServers through its unique modular
QuickSpecs. HP Smart Array 5312 Controller. Overview
Overview Models 238633-B21 238633-291 (Japan) Feature List: High Performance PCI-X Architecture High Capacity Two Ultra 3 SCSI channels support up to 28 drives Modular battery-backed cache design 128 MB
SAS, SATA, and SCSI RAID Controllers Installation and User s Guide
SAS, SATA, and SCSI RAID Controllers Installation and User s Guide 2 Copyright 2006 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
USER S GUIDE. MegaRAID SAS Device Driver Installation. June 2009. 80-00163-01 Rev.D
USER S GUIDE MegaRAID SAS Device Driver Installation June 2009 80-00163-01 Rev.D This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by
Hardware RAID vs. Software RAID: Which Implementation is Best for my Application?
STORAGE SOLUTIONS WHITE PAPER Hardware vs. Software : Which Implementation is Best for my Application? Contents Introduction...1 What is?...1 Software...1 Software Implementations...1 Hardware...2 Hardware
IBM ^ xseries ServeRAID Technology
IBM ^ xseries ServeRAID Technology Reliability through RAID technology Executive Summary: t long ago, business-critical computing on industry-standard platforms was unheard of. Proprietary systems were
USER S GUIDE. MegaRAID Configuration Software. February 2003 Version 1.0 DB15-000269-00
USER S GUIDE MegaRAID Configuration Software February 2003 DB15-000269-00 This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
Intel RAID Software User s Guide:
Intel RAID Software User s Guide: Intel Embedded Server RAID Technology II Intel Integrated Server RAID Intel RAID Controllers using the Intel RAID Software Stack 3 Revision 8.0 August, 2008 Intel Order
SATA II 4 Port PCI RAID Card RC217 User Manual
SATA II 4 Port PCI RAID Card RC217 SATA II 4 Port PCI RAID Card This Manual is for many Models of SATAII RAID5 HBA that uses Silicon Image SATA II SiI3124 chipset: 1) 32bit PCI bus host card 2) 64bit PCI-X
How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S
Overview The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The low profile, half height card has 8 ports and utilizes DDR2-800 memory. The P212
MegaRAID SAS Device Driver Installation
MegaRAID SAS Device Driver Installation User Guide 80-00163-01, Rev. K 80-00163-01K Revision History Version and Date Description of Changes 80-00163-01 Rev. K, Updated the supported operating system versions.
Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)
PRIMERGY RX300 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Overview/Note) This chapter explains the overview of the disk array and features of the SCSI array controller. Chapter
PCI ATA 133 RAID Controller Card. User Manual
PCI ATA 133 RAID Controller Card User Manual Features and Benefits Silicon Image SiI 0680 Compliant with UltraDMA6 ATA/133 specifications Compliant with PCI v2.2 Plug-n-Play Provides two independent Ultra
SAS, SATA, and SCSI RAID Controllers Installation and User s Guide
SAS, SATA, and SCSI RAID Controllers Installation and User s Guide 2 Copyright 2005-2006 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide
ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide The ServeRAID H1110 SAS/SATA Controller for IBM System x offers a low-cost enterprise-grade RAID solution for internal
Rocket 750. 40-Channel SATA 6Gb/s PCI-Express 2.0 x8 HBA
Rocket 750 40-Channel SATA 6Gb/s PCI-Express 2.0 x8 HBA Quick Installation Guide v1.0 Dec. 17, 2012 1 Table of Contents HighPoint Rocket 750 HBA... 3 Kit Contents... 3 Board Layout... 4 Hardware Installation...
Intel RAID Software User s Guide:
Intel RAID Software User s Guide: Intel Embedded Server RAID Technology II Intel Integrated Server RAID Intel RAID Controllers using the Intel RAID Software Stack 3 Revision 11.0 July, 2009 Intel Order
Redundancy in enterprise storage networks using dual-domain SAS configurations
Redundancy in enterprise storage networks using dual-domain SAS configurations technology brief Abstract... 2 Introduction... 2 Why dual-domain SAS is important... 2 Single SAS domain... 3 Dual-domain
SATA 150 RAID. user. Model 176767 MAN-176767-UM-1007-01
SATA 150 RAID Controller PCI Card user manual Model 176767 MAN-176767-UM-1007-01 introduction Thank you for purchasing this MANHATTAN SATA 150 RAID Controller PCI Card, Model 176767. The easy-to-follow
ServeRAID M5210 and M5210e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide
ServeRAID M5210 and M5210e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5210 and M5210e SAS/SATA controllers for IBM System x are part of the IBM ServeRAID M Series family
HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler
Overview HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler Models Smart Array 5i Plus Controller and BBWC Enabler bundled Option Kit (for ProLiant DL380 G2, ProLiant DL380
Encore SATA2 RAID PCIe Card
Encore SATA2 RAID PCIe Card User Manual Ver. 2.00 All brand names and trademarks are properties of their Respective owners. 1 Features and Benefits Compliant with PCI Express Base Specification 1.0a Compliant
QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview
DA - 12587 Worldwide Version 5 2.16.2007 Page 1 Overview The HP StorageWorks SB40c is a half-height c-class storage blade supporting up to six hot-plug Small Form Factor (SFF) Serial Attached SCSI (SAS)
MegaRAID SAS 9271-4i and SAS 9271-8i RAID Controllers
MegaRAID SAS 9271-4i and SAS 9271-8i RAID Controllers Quick Installation Guide 53822-00, Rev. A 53822-00A Revision History Version and Date 53822-00, Rev. A, June, 2012. Initial release of the document.
High Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + Rocket EJ220 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-
SATA 6G PCIe Card User Manual Model: UGT-ST622
SATA 6G PCIe Card User Manual Model: UGT-ST622 All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction... 3 1.1 Product Introduction...
MSM Software Feature Difference Between the MR Controller and the IR Controller
MSM Software Feature Difference Between the MR Controller and the IR Controller Systems Engineering Note S11252, Version 1.0 DB05-000341-00 For a comprehensive list of changes to this document, see the
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
How To Use The Serveraid M1115 Sata Controller On An Ipa 4.5 (Powerpc) Or Ipa 5.5.2 (Powerpci) Server
ServeRAID M1115 SAS/SATA Controller for IBM System x IBM Redbooks Product Guide The ServeRAID M1115 SAS/SATA Controller for IBM System x is a part of the IBM ServeRAID M Series family that offers a complete
Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.
Filename: SAS - PCI Express Bandwidth - Infostor v5.doc Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI Article for InfoStor November 2003 Paul Griffith Adaptec, Inc. Server
QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller
Overview The HP Smart Array P411 is HP's external connect only, PCI Express (PCIe) 2.0 Serial Attached SCSI (SAS) RAID controller for Integrity rack optimized servers. The low profile, half height card
SATA II-150 PCI Quick Installation Guide
SATA II-150 PCI Quick Installation Guide Introducing the SATA II-150 PCI The SATA II-150 PCI is an ultra high-speed dual channel Serial ATA Generation 2 controller for use in PCI enabled systems. Features
Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC. PERC 3 User s Guide. www.dell.com support.dell.com
Dell PowerEdge Expandable RAID Controller 3/QC, 3/DC, 3/DCL and 3/SC PERC 3 User s Guide www.dell.com support.dell.com Information in this document is subject to change without notice. 2002 Dell Computer
Serial ATA RAID PCI Card
Serial ATA RAID PCI Card User Manual 1 Features Silicon Image SiI3512 SATA controller chip Compliant with PCI Specification, Rev. 2.3 Compliant with Serial ATA 1.0 specification Provides two independent
readme.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-2045/ASR-2405 Unified Serial Controllers Adaptec ASR-5405Z/ASR-5445Z/ASR-5805Z
SATA II-150 PCI RAID
SATA II-150 PCI RAID Quick Installation Guide Introducing the SATA II-150 PCI RAID The SATA II-150 PCI RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI enabled
3ware SATA+SAS RAID Controller Card Software User Guide
3ware SATA+SAS RAID Controller Card Software User Guide User Guide Supports the 9750 RAID Controller Card Family Models 9750-4i, 9750-8i, 9750-4i4e, 9750-8e, 9750-16i4e, and 9750-24i4e PN: 45414-01, Rev.
SATA II PCIe RAID Quick Installation Guide
SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled
5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX
Intel Server Board S5520 5520UR Intel Server System SR600 00UR Intel Server System SR600 00UR URHS Intel Server System SR625UR Intel Server System SR625UR 625URSAS Intel Server System SR2600 00UR URBRP
Benefits of Intel Matrix Storage Technology
Benefits of Intel Matrix Storage Technology White Paper December 2005 Document Number: 310855-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3
Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3 Author: Conor Malone, VP Engineering, Hyve Solutions 1 Scope This document discusses the requirements and specifications
Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide
Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide The Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter enables high-performance connection
LSI SAS inside 60% of servers. 21 million LSI SAS & MegaRAID solutions shipped over last 3 years. 9 out of 10 top server vendors use MegaRAID
The vast majority of the world s servers count on LSI SAS & MegaRAID Trust us, build the LSI credibility in storage, SAS, RAID Server installed base = 36M LSI SAS inside 60% of servers 21 million LSI SAS
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering StarTech ID: PEXMSATA343 The PEXMSATA343 3-Port PCI Express 2.0 SATA Card with HyperDuo adds an internal
3-Port FireWire 800/400 PCI Host Card
3-Port FireWire 800/400 PCI Host Card 400 FireWire Low Included FireWire Upgrade to FireWire800! U S E R S M A N U A L Low FireWire 400 Included Package Contents : 1 3-Port FireWire 800/400 PCI Host Card
QuickSpecs. Models. Overview
Overview The HP Smart Array P812 is HP's 24 port Serial Attached SCSI (SAS) RAID controller with PCI Express (PCIe). This high performance SAS RAID controller provides high levels of reliability for HP
-------------------------------------------------------------------- README.TXT
README.TXT ICP ICP9085LI/ICP5085BR SAS RAID Controller ICP ICP9047MA/ICP9087MA SATA RAID Controller ICP ICP9014RO/ICP9024RO SCSI RAID Controller ICP ICP5805BL/ICP5045BL/ICP5085BL/ICP5125BR/ICP5165BR Unified
USB 3.0 4-Port PCI Express Card
USB 3.0 4-Port PCI Express Card User Manual Model: UGT-PC341 All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction... 3 1.1 Product
High Availability Server Clustering Solutions
White Paper High vailability Server Clustering Solutions Extending the benefits of technology into the server arena Intel in Communications Contents Executive Summary 3 Extending Protection to Storage
SATA+Ultra ATA RAID CONTROLLER RC212. User Manual
SATA+Ultra ATA RAID CONTROLLER RC212 Contents Feature and benefits Package contents System requirement Magic Switch introduction and jumper setting Hardware installation Important message for user RAID
Serial ATA 4-Channel RAID Quick Installation Guide
Serial ATA 4-Channel RAID Quick Installation Guide Introducing the Serial ATA 4-Channel RAID The Serial ATA 4-Channel RAID is an ultra high-speed four channel Serial ATA controller for use in Pentium class
RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2
RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2 HP-UX 11i v3 HP Part Number: 5991-0448_ed2 Published: August 2010 Edition: 2 Copyright 2010 Hewlett-Packard Development Company,
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express 2.0 SATA Controller Card enables 4 AHCI SATA III
MegaRAID RAID Controller Configuration Software Guide
MegaRAID RAID Controller Configuration Software Guide MAN-MR-GENSW 7/20/00 Copyright 2001 LSI Logic Corporation All rights reserved. LSI Logic Corporation 6145-D Northbelt Parkway Norcross, GA 30071 This
SATA II PCIe RAID Quick Installation Guide
SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled
N8103-149/150/151/160 RAID Controller. N8103-156 MegaRAID CacheCade. Feature Overview
N8103-149/150/151/160 RAID Controller N8103-156 MegaRAID CacheCade Feature Overview April 2012 Rev.1.0 NEC Corporation Contents 1 Introduction... 3 2 Types of RAID Controllers... 3 3 New Features of RAID