SECTION.3400 - MECHANICAL: ELECTRICAL: PLUMBING



Similar documents
R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Mechanical, Plumbing, and Fire Protection Conditions

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Mike Holt s Illustrated Guide to. Rule , Articles 445, 700, 701, and 702. Based on the 2011 NEC

FIRE ALARM SYSTEM RECORD OF COMPLETION

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

FIRE ALARM SYSTEM RECORD OF COMPLETION

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities

NEW YORK. Downloaded

Winnipeg Fire Department Fire Prevention Branch

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Element D Services Plumbing

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Bold items are particular to the City of Euless

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

2007 ICC FINAL ACTION AGENDA

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

Electrical. This section applies to the design and installation of building power distribution systems.

Single Family Residential Basement Finish

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

Ch. 205 PLANT & EQUIPMENT STANDARDS 28 CHAPTER 205. PHYSICAL PLANT AND EQUIPMENT STANDARDS FOR LONG-TERM CARE NURSING FACILITIES

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

MISSION CRITICAL FACILITIES DESIGN UPS BATTERY ROOM ENVIRONMENT CRITICAL DESIGN CONSIDERATIONS

Electrical Contractors. and the. New Jersey. Rehabilitation Code

Presentation to Senate Select Committee on Government Facilities: Deferred Maintenance for State Supported Living Centers and State Hospitals

ELECTRICAL EMERGENCY SYSTEM PLAN REVIEW OVERVIEW OF CODE REQUIREMENTS

City of Elk River BASEMENT Office Use Only

Top Commercial / Residential Electrical Requirements *

Building Permit Application

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

PROPERTY INSPECTION REPORT

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

Inspections must be conducted every three years in order to maintain an "approved" status on the City Of Bozeman Safe Rental Unit List.

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Section 10: Emergency and Standby Power Systems

Page 1 of 5 COMPLIANCE CHECKLIST. > Hospice Inpatient Facility Nursing Care Unit

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

TEXT (CO Detection Commercial Buildings Final) Part 1228 of Title 19 NYCRR is amended by adding a new section , to read as follows:

Module 4, Lesson 12 Fire Alarm Systems

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

SECTION FIRE ALARM AND DETECTION SYSTEM

CBD-233. Fire Alarm and Detection Systems

Housing Quality Standards Inspection Checklist

Fire Pump Plan Review March 2010

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

EXHIBIT A SCOPE OF WORK

Tech Report 2: Electrical System Existing Conditions

Effective June 27, TEXT (CO Detection Commercial Buildings)

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

HOUSING QUALITY STANDARDS (HQS)

RHODE ISLAND. Downloaded

ELECTRICAL REQUIREMENTS FOR HEALTH CARE FACILITIES

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

Name Of Occupancy Date. Yes No Describe

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Important Ontario Fire Code Information for Building Owners in the City of Windsor

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

Vari Inspection Services

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

Finance and Administration Department 907 Billy Mitchell Blvd. P: (210) Fire Alarm Permit Application

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Mobile Fire Rescue Department Bureau of Fire Prevention

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

FIRE DETECTION AND ALARM SYSTEMS

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

Element D Services Plumbing

Inspecton Report. Property Address:

Element D Services Electrical

Prime Power Services, Inc. Georgia, Carolinas NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010

How To Build A Basement House

SUBJECT CAN: Temporary Systems, Utilities and Equipment. Effective: 4/09/2013. CODE SECTION 2010 California Building Code (CBC)

Operating Room Manual

Health Care Plan Review Unit

Module 5. Fire and Emergency Alarm System Part I- Basics

In an effort to improve the city s building permit and inspection processes the building permit fee schedule has been revised and updated.

Print Shop/Mail Room

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

Planned, Limited Notice and Emergency Outage Guidelines

Energy Efficiency HOSPITALITY.

Questions and Answers for Heating and A/C Contractors

Minimum Housing and Health Standards

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

City of Bettendorf Fire Alarm System Requirements

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

HERNANDO COUNTY FIRE ALARM GUIDELINES

Transcription:

SECTION.3400 - MECHANICAL: ELECTRICAL: PLUMBING 10A NCAC 13D.3401 HEATING AND AIR CONDITIONING Heating and cooling systems shall meet the American Society of Heating, Refrigerating, and Air Conditioning Engineers Inc. Guide [which is incorporated by reference, including all subsequent amendments; copies of this document may be obtained from the American Society of Heating, Refrigerating & Air Conditioning Engineers Inc. at 1791 Tullie Circle NE, Atlanta, GA 30329 at a cost of one hundred nineteen dollars ($119.00.)]; and the National Fire Protection Association Code 90A, [current addition with all subsequent amendments which is adopted by reference; copies of this code may be obtained from the National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy,MA 02269-9101 at a cost of nineteen dollars and fifty cents ($19.50)] with the following modifications: (1) Drug rooms must have positive pressure with relationship to adjacent areas. (2) Environmental temperature control systems shall be capable of maintaining temperatures in the facility at 72 degrees F. minimum in the heating season and a maximum of 81 degrees F. during the non-heating season. (3) Rooms designated for isolation shall have negative or positive pressure with relationship to adjacent areas depending upon the type of patient to be isolated. Exhaust for isolation rooms shall be ducted to the outdoors with exhaust fans located at the discharge end of the duct. History Note: 10A NCAC 13D.3402 EMERGENCY ELECTRICAL SERVICE Emergency electrical service shall be provided for use in the event of failure of the normal electrical service. This emergency service shall consist of the following: (1) In any existing facility, the following shall be provided: (a) (b) (c) type 1 or 2 emergency lights as required by the North Carolina State Building Code, Electrical Code; additional emergency lights for all nursing stations, drug preparation and storage areas, and for the telephone switchboard, if applicable; one or more portable battery-powered lamps at each nursing station; and

(d) a suitable source of emergency power for life-sustaining equipment, if the facility admits or cares for occupants needing such equipment, to ensure continuous operation for a minimum of 72 hours. (2) Any new addition to an existing facility shall meet the same requirements as new construction. (3) Any conversion of an existing building (hotel, motel, abandoned hospital, abandoned school, or other building) shall meet the same requirements for emergency electrical services as required for new construction. (4) An emergency generating set, including the prime mover and generator, shall be located on the premises and shall be reserved exclusively for supplying the emergency electrical system. (5) Emergency electrical services shall be provided as required by Rule.3101(b) of this Subchapter with the following modifications: (a) (b) (c) Section (B)(2) contained in Section 517-10 of the North Carolina State Building Code, Electrical Code shall not apply to new facilities. Egress lighting shall be connected to the essential electrical system at exterior of exits. Task illumination in the switchgear and boiler rooms shall be connected to the essential electrical system. (6) The following equipment, devices, and systems which are essential to life safety, and the protection of important equipment or vital materials shall be connected to the emergency electrical system as follows: (a) (b) (c) (d) (e) nurses' calling system; fire pump if installed; sewerage lift or sump pumps if installed; one elevator, where elevators are used for vertical transportation of patients; equipment such as burners and pumps necessary for operation of one or more boilers and their necessary auxiliaries and controls, required for heating and sterilization, if installed;

(f) equipment necessary for maintaining telephone service. (7) A minimum of one dedicated emergency branch circuit per bed for ventilator dependent patients is required in addition to the normal system receptacle at each bed location required by the North Carolina State Building Code, Electrical Code. This emergency circuit shall be provided with a minimum of two duplex receptacles identified for emergency use. Additional emergency branch circuits/receptacles shall be provided where the electrical life support needs of the patient exceed the minimum requirements stated in this Paragraph. Each emergency circuit serving ventilator dependent patients shall be fed from the automatically transferred critical branch of the essential electrical system. This Paragraph shall apply to both new and existing facilities. (8) Heating equipment provided for ventilator dependent patient bedrooms shall be connected to the critical branch of the essential electrical system and arranged for delayed automatic or manual connection to the emergency power source if the heating equipment depends upon electricity for proper operation. This Paragraph shall apply to both new and existing facilities. (9) Task lighting connected to the automatically transferred critical branch of the essential electrical system shall be provided for each ventilator dependent patient bedroom. This Paragraph shall apply to both new and existing facilities. (10) Where electricity is the only source of power normally used for space heating, the emergency service shall provide for heating of patient rooms. Emergency heating of patient rooms will not be required in areas where the facility is supplied by at least two separate generating sources, or a network distribution system with the facility feeders so routed, connected, and protected that a fault any place between the generators and the facility will not likely cause an interruption. (11) The emergency electrical system shall be so controlled that after interruption of the normal electric power supply, the generator is brought to full voltage and frequency and connected with 10 seconds through one or more primary automatic transfer switches to all emergency lighting, alarms, nurses' call, and equipment necessary for maintaining telephone service. All other lighting and equipment required to be connected to the emergency system shall either be connected through the 10 second primary automatic transfer switching or shall be subsequently connected through other automatic or manual transfer switching. Receptacles connected to the emergency system shall be distinctively marked for identification.

(12) Sufficient fuel shall be stored for the operation of the emergency generator for a period not less than 72 hours, on a 24-hour per day operational basis. The generator system shall be tested and maintained per National Fire Protection Association (NFPA) code 99, current addition with all subsequent amendments, which is adopted by reference. Copies of this code may be obtained from the National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy, MA 02269-9101 at a cost of thirty one dollars ($31.00). Records of running time shall be maintained and kept available for reference. (13) Existing facilities shall have electrical systems that comply with licensure standards in effect at the time a license is first issued. Any remodeling that results in changes in service delivery shall comply with current licensure requirements to support the delivery of those services. History Note: 10A NCAC 13D.3403 GENERAL ELECTRICAL (a) All main water supply shut off valves in the sprinkler system shall be electronically supervised so that if any valve is closed an alarm will sound at a continuously manned central station. (b) No two adjacent emergency lighting fixtures shall be on the same circuit. (c) Receptacles in bathrooms shall have ground fault protection. (d) Each patient bed location shall be provided with a minimum of four single or two duplex receptacles. Two single receptacles or one duplex receptacle shall be connected to the critical branch of the emergency power system at each bed location. Each patient bed location shall also be provided with a minimum of two single receptacles or one duplex receptacle connected to the normal electrical system. (e) Each patient bed location shall be supplied by at least two branch circuits. (f) The fire alarm system shall be installed to transmit an alarm automatically to the fire department that is legally committed to serve the area in which the facility is located, by the most direct and reliable method approved by local ordinances. (g) In patient areas, fire alarms shall be gongs or chimes rather than horns or bells. (h) All receptacles in patient use areas must be grounded by an insulated conductor sized in accordance with Table 250-95 of the North Carolina State Building Code, Electrical Code.

History Note: 10A NCAC 13D.3404 OTHER (a) In general patient areas, each room shall be served by at least one calling station and each bed shall be provided with a call button. Two call buttons serving adjacent beds may be served by one calling station. Calls shall register with the floor staff and shall activate a visible signal in the corridor at the patient's or resident's door. In multi-corridor nursing units, additional visible signals shall be installed at corridor intersections. In rooms containing two or more calling stations, indicating lights shall be provided at each station. Nurses' calling systems which provide two-way voice communication shall be equipped with an indicating light at each calling station which lights and remains lighted as long as the voice circuit is operating. A nurses' call emergency button shall be provided for patients' and residents' use at each patient and resident toilet, bath, and shower. (b) At least one telephone shall be available in each area to which patients are admitted and additional telephones or extensions as are necessary to ensure availability in case of need. (c) General outdoor lighting shall be provided adequate to illuminate walkways and drive. (d) A flow of hot water shall be within safety ranges specified as follows: Patient Areas - 6 1/2 gallons per hour per bed and at a temperature of 100-116 degrees F; and Dietary Services - 4 gallons per hour per bed and at a minimum temperature of 140 degrees F; and Laundry Area - 4 1/2 gallons per hour per bed and at a minimum temperature of 140 degrees F. (e) Plumbing systems shall meet the requirements of the North Carolina State Building Code, Plumbing Code. (f) Medical gas and vacuum systems shall be installed, tested, and maintained in accordance with the National Fire Protection Code 99 current addition with all subsequent amendments, which is adopted by reference. Copies of this code may be obtained from the National Fire Protection Association, 1 Batterymarch Park, P.O. Box 9101, Quincy,MA 02269-9101 at a cost of thirty one dollars ($31.00). (g) The Administrator shall assure that isolation facilities are available and used for any patient admitted or retained with a communicable disease.

(h) Each facility shall have a control system or procedure to aid staff in the supervision of patients who wander or are disoriented. This requirement shall apply to new and existing facilities. History Note: