NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION
|
|
|
- Marjory Cain
- 9 years ago
- Views:
Transcription
1 NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION Fire and Life-Safety Group (FLS) I. EMERGENCY PROCEDURES The emergency procedures for natural gas emergencies are similar to that for fire emergencies. All incidents will use the Incident Command System. The University of Colorado Police Department (UCPD) officer at the scene will be in charge until the arrival of the Boulder Fire Department (BFD). Upon their arrival, the BFD commanding officer will be in charge of the emergency and the building. II. NATURAL GAS LEAK/SMELL INSIDE BUILDINGS GENERAL GUIDELINES If you smell natural gas: Do not turn electrical switches on or off. Do not use a phone or a cellular phone inside the building. Do not use any potential ignition sources or open flames. Use common sense and never take risks that may endanger you or others, do not return to the building unless advised to do so by the BFD or UCPD. If it is possible, open the doors and windows, to ventilate the building. However, do not spend additional time opening doors or windows if there is an imminent danger of explosion or fire that would jeopardize your safety. Always leave the building quickly by the fastest possible route. Follow the emergency procedures listed below. EMERGENCY PROCEDURES
2 When you suspect or detect a natural gas leak or observe a flammable material spill, follow the emergency procedures listed below regardless of intensity of odor or size of spill. IF YOU DETECT OR SUSPECT A NATURAL GAS LEAK 1. Leave the area. 2. Sound the fire alarm. (NOTE: Because of its low odor threshold, natural gas is sensed far in advance of high concentrations and pulling the fire alarm will not add to the fire risk already present by static electricity and electrical and mechanical equipment in the building.) 3. Immediately evacuate the building via the shortest and safest exit route. If possible to accomplish within seconds, leave windows and exterior doors open to ventilate the area. 4. Do not use elevators; always use stairs. 5. Go to a safe area or to a pre-assigned exterior assembly area for your building. 6. Call from the nearest phone in safe area. 7. Await emergency response personnel at safe location. 8. If you know or suspect that someone is missing or trapped, contact the emergency personnel outside the building. 9. If you are trapped during a gas release/emergency, close all doors between you and the gas leak. Stuff the cracks around the doors. Open windows or other exterior openings for fresh air and ventilation. Wait at a safe window and signal/call for help. If there is a phone in the room, call and tell them exactly where you are. SERVICE CENTER RESPONSIBILITIES If there is a possible life safety issue, e.g., gas odor, Service Center is to promptly transfer the call to or have the caller hang up and immediately call if the transfer cannot be completed normally. Interviewing the caller to determine more in-depth information would only delay the emergency response. It is appropriate for the Service Center dispatcher to verify with UCPD
3 dispatch that they received the transferred call. UCPD dispatchers are trained to interview individuals to determine the relative threat to life safety, and to initiate a notification to appropriate agencies who will then proceed promptly to the scene to assess the situation. Also, Service Center is to notify all personnel in all tunnels and in the mechanical rooms of the building where the gas smell has been reported. Service Center is to contact FM plumbers as soon as possible to avoid delays. Upon coordination with UCPD dispatchers, the Service Center is to notify all Facilities Management (FM) based on the call-out list. OTHER AGENCIES' RESPONSIBILITIES UCPD and BFD will set up an incident command post, and determine what actions are necessary to protect the life safety of responders, building occupants, and all other personnel adjacent to the facility. UCPD dispatchers will notify the responders including FM Service Center, BFD, Xcel Energy, and Housing & Dining Services (HDS) personnel that are on the call-out list and all other emergency responders based on the call-out list. UCPD will direct the Service Center to notify FM responders as soon as the life safety responder protocols are initiated. FM, HDS and/or BFD personnel should close the main gas valve to the building when so directed by the incident commander on the scene. (Note: Xcel Energy has a relatively timely response during week days from approximately 7:00 am to 7:00 pm. However, outside these hours, the Xcel Energy response time may be 1-2 hours.) III. NATURAL GAS LEAK/SMELL OUTSIDE BUILDINGS If gas odor is sensed in any building, then the procedures summarized under section II, above, apply. If gas odor is strictly limited to areas outside buildings, Service Center is still required to transfer the caller to and notify all personnel in tunnels. UCPD dispatchers will notify the responders including FM Service Center, BFD, Xcel Energy, and HDS personnel that are on the call-out list and all other emergency responders based on the call-out list. UCPD will direct the Service Center to notify FM responders as soon as the life safety responder protocols are initiated. GENERAL GUIDELINES
4 If gas odor is sensed in any building, then the procedures summarized under section II, above, apply. Otherwise, move to an area outside of the natural gas odor area, call and notify them of the situation. Do not use any potential ignition sources or open flames, use common sense and never take risks that may endanger you or others. EMERGENCY PROCEDURES Move away from the area suspected of gas leak and follow the directions given by the UCPD and BFD. If you are the person who discovered the gas smell, call and follow the directions given by the operator. SERVICE CENTER RESPONSIBILITIES If there is a possible life safety issue, e.g., gas odor, Service Center is to promptly transfer the call to or have the caller hang up and immediately call if the transfer cannot be completed normally. Interviewing the caller to determine more in-depth information would only delay the emergency response. It is appropriate for the Service Center dispatcher to verify with UCPD dispatch that they received the transferred call. UCPD dispatchers are trained to interview individuals to determine the relative threat to life safety, and to initiate a notification to appropriate agencies who will then proceed promptly to the scene to assess the situation. Also, Service Center is to notify all personnel in all tunnels and in the mechanical rooms of the building where the gas smell has been reported. Service Center is to contact FM plumbers as soon as possible to avoid delays. Upon coordination with UCPD dispatchers, the Service Center is to notify all Facilities Management (FM) based on the call-out list. OTHER AGENCIES' RESPONSIBILITIES UCPD and BFD will set up an incident command post, and determine what actions are necessary to protect the life safety of responders, building occupants, and all other personnel adjacent to the facility. UCPD dispatchers will notify the responders including FM Service Center, BFD, Xcel Energy, and HDS personnel that are on the call-out list and all other emergency responders based on the call-out list. UCPD will direct the Service Center to notify FM responders as soon as the life safety responder protocols are initiated.
5 FM, HDS and/or BFD personnel should close the main gas valve to the building when so directed by the incident commander on the scene. (Note: Xcel Energy has a relatively timely response during week days from approximately 7:00 am to 7:00 pm. However, outside these hours, the Xcel Energy response time may be 1-2 hours.) IV. NATURAL GAS ACCIDENT PREVENTION The following safety guidelines are to be considered. Safety Guidelines for Occupants A major part of any prevention program is good housekeeping practices. Keep all combustible materials away from the flame of your gas appliances. Follow manufacturer's instructions in the care and operation of gas-fired appliances. Don't block furnace room air vents. Gas appliances require air to burn fuel completely and operate efficiently. A yellowish flame can signal improper operation. If the pilot flame on a gas appliance goes out, shut off the gas supply at the appliance's valve and allow time for accumulated gas to escape before attempting to re-light pilot flame. Have qualified personnel handle natural gas-related repair and installation jobs. See CU Standards for Licenses and procedures required. Safety Rules for FM, Contractor and Others Conducting Natural Gas Related Work Contact the Utility Notification Center of Colorado (UNCC) at prior to any digging. During gas leak/smell inside buildings, if possible, cut off all electric circuits at a remote source to eliminate operation of automatic switches in the dangerous area. Safety flashlights designed for use in hazardous atmospheres are recommended for use in such emergencies.
6 Investigate other buildings in the immediate area to determine the presence of escaping gas therein. Follow manufacturer's instructions in the care and operation of gas-fired appliances. Have qualified personnel handle natural gas-related repair and installation jobs. See CU standards for Licenses and procedures required. Make sure the flues of automatically controlled appliances are corrosion-free, securely attached, and correctly vented. If the pilot flame on a gas appliance goes out, shut off the gas supply at the appliance's valve and allow time for accumulated gas to escape. When the gas supply is to be turned off, it is the duty of the qualified agency to notify all affected users. Before the gas is turned off to the premises or section of piping to be serviced, all equipment shutoff valves are to be turned off. Exception: In cases of emergency, this requirement does not apply. A leak test is to be performed to determine that all equipment is turned off in the piping section affected. Exception: In cases of emergency, this requirement does not apply. Shut off the supply of gas to the areas involved. Lock-out/tag-out any closed valves where necessary. All gas piping installations, equipment installations, and modifications to existing systems are to be performed with the gas turned off and the piping purged in accordance with the National Fuel Gas Code (NFGC), NFPA-54 and the International Fuel Gas Code (IFGC). Hot taps are not allowed on campus. This practice is acceptable when approved by plumbing code official and only for large gas mains in large open fields; it is not allowed for any gas piping inside a building. When interruptions in work occur while repairs or alterations are being made to an existing piping system, the system is to be left in a safe condition. Where work is being performed on piping that contains or has contained gas, the following is to apply: 1. Provisions for electrical continuity are to be made before alterations are made in a metallic piping system.
7 2. Smoking, open flames, lanterns, welding, or other sources of ignition are not to be permitted. 3. A metallic electrical bond is to be installed around the location of cuts in metallic gas pipes made by other than cutting torches. If cutting torches, welding, or other sources of ignition are unavoidable, it must be determined that all sources of gas or gas-air mixtures have been secured and that all flammable gas or liquids have been cleared from the area. Piping is to be purged as required in NFGC/IFGC before welding or cutting with a torch is attempted. 4. Artificial illumination is to be restricted to listed safety-type flashlights and safety lamps. Electric switches are not to be operated, on or off. The piping system is to withstand the test pressure specified without showing any evidence of leak or other defects. Any reduction of test pressures as indicated by pressure gauges is to be deemed to indicate the presence of a leak unless such reduction can be readily attributed to some other cause. The leak is to be located by means of an approved gas detector, a non-corrosive leak detection fluid, or other approved leak detection methods. Matches, candles, open flames, or other methods that provide a source of ignition are not to be used. Where leak or other defects are located, the affected portion of the piping system is to be repaired or replaced and re-tested; see NFGC/IFGC. Leak testing of new installations and remodels are to be in strict accordance with the requirements of the NFGC/IFGC. When gas piping is to be opened for servicing, addition, or modification, the section to be worked on is to be turned off from the gas supply at the nearest convenient point and the line pressure vented to the outdoors or to ventilated areas of sufficient size to prevent accumulation of flammable mixtures. If the pipe section exceeds the lengths shown in NFGC/IFGC, the remaining gas is to be displaced with an inert gas. When piping full of air is placed in operation, the air in the piping is to be displaced with fuel gas, provided the piping does not exceed the length shown in NFGC/IFGC. The air can be safely displaced with fuel gas provided that a moderately rapid and continuous flow of fuel gas is introduced at one end of the line and air is vented out at the other end. The fuel gas flow shall be continued without interruption until the vented gas is free of air. The point of discharge is not to be left unattended during purging. The vent is then to be closed. If the piping exceeds the lengths shown in NFGC/IFGC, the air in the piping is to be displaced with an inert gas, and the inert gas is then to be displaced with fuel gas.
8 The open end of piping systems being purged are not to discharge into confined spaces or areas where there are sources of ignition unless precautions are taken to perform this operation in a safe manner by ventilation of the space, control of purging rate, and elimination of all hazardous conditions.
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES
CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.
Workplace Fire Safety
Teaching Guide Workplace Fire Safety for staff Seattle Fire Department Fire Prevention Division Workplace Fire Safety Instructor Outline Introduction Goals: To ensure that employees are knowledgeable in
Emergency Plan. This emergency plan provides a format of data essential in an emergency situation.
Emergency Plan A. Introduction This emergency plan provides a format of data essential in an emergency situation. B. Definition of Emergency Incident An emergency condition exists when we determine that
How To Handle An Emergency At A Strata Corporation
24 HOUR ANSWERING SERVICE The regular office hours at our firm are 9:00 am to 5:00 pm Monday to Friday. After these regular hours, the same telephone number is answered by a Telephone Answering Service,
Hotel Fire Safety for staff
Teaching Guide Hotel Fire Safety for staff Seattle Fire Department Fire Prevention Division Hotel Fire Safety Instructor Outline Introduction Goals: To ensure that hotel employees are knowledgeable in
Fire Safety PROCEDURES January 2011
Fire Safety PROCEDURES January 2011 [email protected] Campus Phones EMERGENCY Dial 911 Fire Safety Service is the focal point for the coordinated administration of the University Fire Safety program and
emergency action guide
emergency action guide IN THE EVENT OF LIFE-THREATENING OR EXTREME EMERGENCY CALL 911 FIRST. Central Campus Public Safety Dial 6666 from campus phone or call 215.641.6666 West Campus Public Safety Dial
natural gas Control control of of Natural Gas in Emergency Situations
control of Control of Natural Gas natural gas in Emergency Situations 800 North Third Street Suite 301 Harrisburg, PA 17102 717.901.0600 www.energypa.org G as company representatives are available around
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
FIRE SAFETY ONLINE TRAINING
INTRODUCTION This Fire Safety Training module is designed to teach you preventive measures that will eliminate or minimize causes of fire or fire hazards in the workplace, and to teach you proper emergency
OREGON FIRE CODE Interpretations and Technical Advisories
OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application
FIRE SAFETY FOR OFFICE WORKERS
FIRE SAFETY FOR OFFICE WORKERS This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the program and the subject
Fire Safety Log Book
Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton
Natural Gas Safety. What You Need to Know
Natural Gas Safety What You Need to Know Knowledge is Safety Approximately 52% of all U.S. households use natural gas for Home heating Cooking Water heaters Gas logs Outdoor gas grills Our Local History
EMERGENCY INFORMATION GUIDE
EMERGENCY INFORMATION GUIDE DECLARING STATE OF EMERGENCY/INFORMING THE PUBLIC The authority to declare a campus state of emergency rests with the College President or designee. During the period of any
FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes
FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,
Winnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances
Service Bulletin DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances SA-008 Due to the unfortunate flooding experienced by many areas in the Midwest in recent months,
EMERGENCY PROCEDURES
EMERGENCY PROCEDURES Introduction Being prepared is the first step towards preventing and/or handling emergency situations. Because your safety is of utmost importance, SOLEX College has created this document
Natural Gas Emergencies
Natural Gas Emergencies Purpose To protect the personnel within the department, and citizens from the hazards involved in a natural gas emergency. The Incident Commander is to use his/her best judgment
Sam Houston State University
Sam Houston State University Lowman Student Center EMERGENCY PROCEDURES July 2007 Emergency Procedures Found in this Document General Information for any Emergency Situation in the LSC...... 2 Vandalism,
St. John s University
St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
Factors to Consider When Developing an Evacuation Plan
The following should be viewed only as suggestions: Factors to Consider When Developing an Evacuation Plan 1. You must identify your document with a specific title and explanation. Example: Evacuation
WORKPLACE WRITTEN PROCEDURES OH&S Regulation, Section 3
WORKPLACE WRITTEN PROCEDURES OH&S Regulation, Section 3 BASIC REQUIREMENTS Every worker must be made aware of the location of First Aid for the workplace and how to call the First Aid attendant, if one
REACT. Rapid Emergency Action Checklist. The University of Toledo Health Science Campus. Emergency Contact Information for Department or Lab
Emergency Contact Information for Department or Lab Main contact: Phone number: Back-up contact: Phone number: The University of Toledo Health Science Campus Rapid Emergency Action Checklist REACT This
EMERGENCY PROCEDURES
EMERGENCY PROCEDURES In an Emergency Call 911 Using County Telephone System Call 9-911 Fresno County Sheriff 600-3111 Fresno County Security 600-6785 TABLE OF CONTENTS Introduction 3 Accidents 4 Serious
NATURAL GAS SAFETY. Your safety. Our priority. 2013 Update
NATURAL GAS SAFETY Your safety. Our priority. 2013 Update IMPORTANT CONTACT INFORMATION Emergencies: If you suspect a natural gas leak, from a safe place, call 911 and Southwest Gas immediately at 1-877-860-6020,
Preventing Overheated Boiler Incidents
Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What
Material Safety Data Sheet
1 IDENTIFICATION OF THE SUBSTANCE AND COMPANY a) SUBSTANCE: Natural Gas b) COMPANY: Bord Gáis Éireann PO Box 51 Gasworks Road Cork Telephone: (021) 453 4000 Emergency Telephone: 1850 20 50 50 2 COMPOSITION/INFORMATION
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
EMERGENCY PREPAREDNESS PLAN FOR
EMERGENCY PREPAREDNESS PLAN FOR Name of Child Care Center Provided by: 2014 Emergency Preparedness Plan Page 1 TABLE OF CONTENTS Page I: Introduction... 3 II: Emergency Response Organization... 3 III:
WORKING IN CONFINED SPACES GUIDELINES
WORKING IN CONFINED SPACES GUIDELINES Contents 1 Introduction... 2 2 Scope... 2 3 Definitions... 2 4 Responsibilities... 3 4.1 Permit Authoriser... 3 4.2 Permit Receiver... 3 4.3 Responsible UOW Officer...
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Fire Safety Report 2014-2015. Fire Statistics 2013-2014-2015
Fire Safety Report 2014-2015 Fire Statistics 2013-2014-2015 Fire Log 2013-2014-2015 The New York Conservatory for Dramatic Arts Annual Fire Safety Report for Campus Housing 2014-2015 In August 2008, the
Safe Operating Procedure
Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the
HOT WORK PERMIT PROCEDURES
COLUMBIA UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY MEDICAL CENTER February 2010 1 TABLE OF CONTENTS A. PURPOSE 3 B. SCOPE 3 C. POLICIES AND PROCEDURES 3-4
SHELTER-IN-PLACE OR EVACUATE
SHELTER-IN-PLACE OR EVACUATE WOULD YOU KNOW WHAT TO DO? A PREPAREDNESS GUIDE FOR THE HOME No matter where you live, your community may experience a natural or man-made disaster a tornado, floor, winter
A. OCCUPANT FIRE PROCEDURES... 3 B. THE TENANT FIRE SAFETY TEAM... 6 C. SENIOR FIRE WARDEN... 7 D. DEPUTY FIRE WARDEN... 8
Brookfield Place BROOKFIELD PLACE Page 2 of 12 OCTOBER 2006 TABLE OF CONTENTS A. OCCUPANT FIRE PROCEDURES... 3 B. THE TENANT FIRE SAFETY TEAM... 6 C. SENIOR FIRE WARDEN... 7 D. DEPUTY FIRE WARDEN... 8
FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE
Page 1 of 10 FIRE ALARM /FIRE PROTECTION OUTAGE/IMPAIRMENT RESPONSE GUIDELINE SYSTEM TESTING 1. Testing of the Fire Alarm and Fire Protection Systems 1.1. The Building Engineer, Electrician, Plumber (or
The University of Texas at San Antonio Environmental Health, Safety and Risk Management
The University of Texas at San Antonio Environmental Health, Safety and Risk Management TO: FROM: UTSA Campus Community John DeLaHunt, MBA, ARM Risk & Life Safety Manager University Fire Marshal J. Brian
Emergency Procedures IF YOU DISCOVER A FIRE. Upon discovering a fire: the following steps are to be taken:
IF YOU DISCOVER A FIRE Upon discovering a fire: the following steps are to be taken: 1. Leave the fire area immediately removing any person in immediate danger. Make sure that doors to the affected area
(Sample) Building Emergency Plan
(Sample) Building Emergency Plan for XXXXXX 2815 Commons Way Cincinnati, OH 45221 August 2016 University of Cincinnati Department of Public Safety Department a 2 Table of Contents A. Introduction B. Components
How To Evacuate The University Of California Building
University of California Washington Center Emergency Evacuation Plan UC Washington Center 1608 Rhode Island Ave., NW Washington, DC 20036 Revised February 16, 2012 I. Purpose of the Plan II. Building Description
PROCEDURES PREVENTION OF ACCIDENTAL IGNITION
Page No: 1 of 7 6.0 PURPOSE (192.751) All possible precautions shall be exercised to prevent the accidental escape and ignition of gas. Whenever possible, potential sources of ignition should be eliminated
East Mississippi Community College. Scooba Campus * Mayhew Campus Department of Public Safety. Campus Emergency Action Plan.
1 East Mississippi Community College Scooba Campus * Mayhew Campus Department of Public Safety Campus Emergency Action Plan Revised 2013 TABLE OF CONTENTS 2 Foreword & Emergency Numbers Page 3 Active Shooter
Fire Response Plan - Code Red
Fire Response Plan - Code Red SUMMARY & PURPOSE The purpose of the Fire Response Plan Code Red is to provide guidelines for hospital personnel to follow during a Code Red. As more fully described below,
Fire Alarm and Protection Impairment Policy and Procedures
1.0 Policy Statement The University of New Haven has developed a Fire Alarm and Protection Impairment Plan in accordance with the National Fire Protection Associations (NFPA) codes. Specific codes referenced
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS
ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for
Emergency WARDEN HANDBOOK. Lets Keep Fire Safety Proactive not Reactive
INTRODUCTION The purpose of this handbook is to provide wardens with their own guide of the procedures to follow during an emergency. This information together with other training and resources can help
POINT UNIVERSITY CAMPUS SECURITY Emergency Response Plan
POINT UNIVERSITY CAMPUS SECURITY Emergency Response Plan Introduction The Point University Emergency Response Plan establishes guidelines for campus-wide communication, service coordination and safety
Implementation Date: May 5, 2009. Table of Contents. Section Description Page. 1.0 Description 1. 2.0 Initial Response 2
Recommended by Emergency Preparedness Committee: April 21, 2009 Recommended by President s Council: May 1, 2009 Approved by Executive Committee: May 5, 2009 NAIT Procedures CS1.2.6 Flood Implementation
Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.
Hazardous Materials Response Clear Creek Fire Authority This plan provides a basic philosophy and strategic plan for hazardous materials situations. All Clear Creek Fire policies and procedures, unless
The Johns Hopkins Hospital and The Johns Hopkins University Health, Safety and Environment Manual Fire Safety:
Page 1 of 10 Keywords: Emergency Room, Evacuation, Evacuation Plans, Fire, Fire Incident Responsibilities, Fire Safety, Gas Shutoff, Inpatient Area, Intensive Care, JHH Fire Incident Responsibilities,
Presented by: Rich Perry Marsh Risk Consulting
Flammable and Combustible Liquids Presented by: Rich Perry Marsh Risk Consulting What s the Big Deal? Flammable and combustible liquids are easily ignited Ignite with explosive force Burn readily and give
EMERGENCY RESPONSE PROCEDURES
EMERGENCY RESPONSE PROCEDURES TO REPORT AN EMERGENCY, CALL: Madonna Public Safety 734-432-5442 from a campus phone 911 or 5442 Livonia Police Department from a campus phone 9-911 from a cell phone 911
CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN
CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN DATE PROPERTY MANAGER ADDRESS Houston, TX _(Zip Code)_ PHONE NUMBER LIFE SAFETY IS THE GOAL OF THIS PLAN. ALL DUTIES CALLED FOR HEREIN SHOULD
SURVIVE INSIDE: Employee Safety in Confined Spaces
SURVIVE INSIDE: Employee Safety in Confined Spaces This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the
Notes. Material 1. Personal Protective Equipment 2.
29CFR 1926.20(b)-Accident Reduction, 29CFR 1926.21- Safety Training & Education 29CFR 1926.20(a)-Unsafe Working Conditions 29 CFR 1910.132-138, the "Personal Protection Equipment" standard. & 20 CFR 1910.134
IN CASE OF EMERGENCY. Emergency Telephone Number 112
IN CASE OF EMERGENCY Emergency Telephone Number 112 Police, Fire, Ambulance Dial 112 in case of fire, medical emergency, serious or life threatening traffic or other accident. Tell the operator: What has
EMERGENCY PROCEDURES
EMERGENCY PROCEDURES IMPORTANT: This document contains procedures to assist you in responding to an on-campus emergency. A variety of scenarios are included, but this document does not purport to cover
SECURITY VULNERABILITY CHECKLIST FOR ACADEMIC AND SMALL CHEMICAL LABORATORY FACILITIES
SECURITY VULNERABILITY CHECKLIST FOR ACADEMIC AND SMALL CHEMICAL LABORATORY FACILITIES by the American Chemical Society, Committee on Chemical Safety, Safe Practices Subcommittee Introduction Terrorism
Spray Booth Guideline
Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Columbia University Department of Public Safety
Columbia University Department of Public Safety Emergency Response Protocols for Faculty & Staff Medical Center Campus 2 EMERGENCY RESPONSE PROTOCOLS FOR FACULTY & STAFF I. Introduction COLUMBIA UNIVERSITY
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
EMERGENCY PREPAREDNESS PLAN
EMERGENCY PREPAREDNESS PLAN Promontory Charter School ----------------Emergency 911--------------------- INTRODUCTION The purpose of this Emergency Preparedness Plan for Promontory Charter School is to
Inspection, Testing and Maintenance
Page 18 ABOUT CODE CORNER CCFS would like to remind you to check with your local Authority Having Jurisdiction (AHJ) for questions and opinions concerning your local Fire and Building Codes. The information
General Confined Space Awareness
Confined Spaces General Confined Space Awareness Confined spaces can be found in many industrial settings, from steel mills to paper mills, from shipyards to farms, and from public utilities to the construction
exit routes and fire protection
exit routes and fire protection OSHA 11 Exit Routes and Fire Protection Osha 11 Exit Routes and Fire Protection Exit routes and fire protection Learning Objectives By the end of this lesson, students will
Tabletop Exercises. Scenario 2 Gas Leak PHASE 1
Scenario 2 Gas Leak PHASE 1 You are the manager of a small newsagent which employs 4 people, including yourself. One Tuesday, at approximately 10am, you are at work when one of your employees mentions
FLA S FIRE SAFETY INITIATIVE
Improving Workers Lives Worldwide FLA S FIRE SAFETY INITIATIVE Preventing fires and saving lives by empowering workers and factory managers SCENARIO 1 OCCURS AT FACTORY ABC, WHICH HAS NOT IMPLEMENTED NECESSARY
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
NORTH BIRMINGHAM ACADEMY
NORTH BIRMINGHAM ACADEMY FIRE AND EVACUATION PROCEDURES FIRE DRILLS: These are carried out once a term. Observations and details of each drill are recorded in the logbook, which is kept by the Assistant
1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;
Fire Action Plan FIRE ACTION PLAN SEStran aims to provide and maintain safe & healthy working conditions, equipment and systems of work for all our employees, and to provide such information, training
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
Residential Fire Safety Policies
Residential Fire Safety Policies Introduction University Housing and Campus Code Compliance and Fire Safety at the City University of New York at Queens College in compliance with the Higher Education
REHABILITATION OF MOBILE HOMES R4 34 606
REHABILITATION OF MOBILE HOMES R4 34 606 PURPOSE The purpose of this program is to provide minimum safety standards for homes manufactured before the implementation of the HUD Manufactured Home Construction
American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems
American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified
Emergency procedures instructions to farm staff
Emergency procedures instructions to farm staff The first priority in the event of an emergency is for the safety of all people present. Emergency phone numbers Dial 111 for Fire/Police/Ambulance 1. Tell
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation
Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation No. 2008-02-I-IA (September 2008) Key Lessons for Safe Handling and Storage of Flammables Ensure that equipment, such as fill
Union College Campus Safety Emergency Action Guide
Union College Campus Safety Emergency Action Guide Emergency Telephone Numbers At Union College, for all campus emergencies dial Campus Safety at ext. 911. (If the line is busy on a second try, dial "6911".)
UNIVERSITY OF TOLEDO
UNIVERSITY OF TOLEDO SUBJECT: INTERIM LIFE SAFETY MEASURES AND INFECTION Procedure No: LS-08-008 CONTROL PROCEDURE STATEMENT Interim life safety and infection control measures will be implemented to protect
Chippewa County Courthouse Security Emergency Procedures. Dial 9 9 1 1 FIRE POLICE AMBULANCE
Chippewa County Courthouse Security Emergency Procedures Dial 9 9 1 1 FIRE POLICE AMBULANCE Table of Contents Introduction... 2 Explosion... 3 Civil Disorder/Threat to Personal Safety... 4 Chemical Spill...
Administrative Policy Memo No. 9 Attachment C April 2010
Administrative Policy Memo No. 9 Attachment C April 2010 Emergency Procedures MEDICAL EMERGENCY 2. Assess the situation. 3. Get help. Call 911 from any office/campus phone or 911 from any pay phone (no
Abnormal Operating Conditions Emergency Plans and Public Awareness Plans for Natural Gas Systems
Abnormal Operating Conditions Emergency Plans and Public Awareness Plans for Natural Gas Systems Contact Information John West Transportation Specialist U.S. Department of Transportation PHMSA Office of
Fire Risk Assessment Safety Checklist
Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory
Reviewed: Revised: 12/09. Page: 1 of 9
Section: Emergency / Disaster Plan II Title/Subject: Clinic Evacuation Policy Number: Reviewed: Revised: 12/09 Page: 1 of 9 Purpose: The purpose of this Emergency Evacuation Plan is to ensure that the
Sample Written Program. For. Flammable Liquids
Sample Written Program For Flammable Liquids 1 Flammable Liquids. (YOUR COMPANY NAME) Purpose Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
EMERGENCY RESPONSE PROCEDURES
EMERGENCY RESPONSE PROCEDURES Emergency Telephone Numbers Life Threatening Emergency................................. 911 Local Police............................. Local Fire and Paramedics.................
FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589.
FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589 Bulletin 16-12 Fire Drills This guideline was developed to assist persons
HealthandSafetyOntario.ca. What is a work permit? Why use a work permit? Types of work permits. When is a work permit needed?
work permits What is a work permit? A work permit is a written form used to authorize jobs that expose workers to serious hazards. It identifies the work to be done, the hazards involved, and the necessary
Millersville University - Office Of Environmental Health & Safety Scope & Application
Confined Space Entry Millersville University - Office Of Environmental Health & Safety Scope & Application The Confined Space Entry (CSE) program applies to the safe working practices for entering and
Module 14 Handling Emergency Situations
Handling Emergency Situations The Shift Lead protects the team, customers and restaurant by monitoring safety. However, you cannot always prevent problems. Sometimes, things happen that you were not expecting