The Harold J. Becker Company, Inc.



Similar documents
Roofing Systems. New Applications / Re-Roofing / Maintenance

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Site Inspection Report

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

COMMERCIAL BUILDING APPLICATIONS

CHAPTER 7: Building Systems ROOFING SYSTEMS

COMPARATIVE PERFORMANCE OF EPDM RUBBER ROOFING MEMBRANE AS PROTECTION AGAINST HAIL DAMAGE

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Building Owners Guide to a Duro-Last System!

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Durapax Coal Tar BUR Application Guide

Avoiding the Landfill: The Recycling of Vinyl Roof Membranes

ROOFS - Guidance for Repair, Maintenance and Replacement

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

Springlok Flashing System

Residential Roofing Guide

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

Roof Inspection Report 3840 Greenway Circle, Lawrence Kansas, Sauer-Danfoss Building

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

The Perfect Fit For Metal Retrofit

SECTION STANDING SEAM METAL ROOFING

Ver. 2. Guide to. Inspecting Residential Brick Veneer

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

Nominal Life Expectancy for Building Components

TARRANT COUNTY DETAIL STANDARDS

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

1.0 Introduction. 2.0 Importance of Integrity Testing. 3.0 How Does EFVM Work? 6.0 Conclusion

ROOF INSPECTION & MAINTENANCE

Construction Coatings

THERMAL AND MOISTURE PROTECTION WATERPROOFING

Roof Repair Project Report. Fairbank Complex 40 Fairbank Road Sudbury, Massachusetts. February 14, RBA Project No

Peel & Seal Self-Stick Roofing Solutions

Cost Comparisons for Common Commercial Wall Systems

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2

CREEK Technical Services, LLC

Roof Systems Overview

GUIDELINE SPECIFICATIONS

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

HEB 38 BLANCO AND WEST AVENUE FLUID APPLIED EPDM RUBBER ROOF RECOVERY SYSTEM APPLICATION

ABSeam Panel Overview and Installation Instructions

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

Roofing & Waterproofing Forensics for the 21 st Century. Peter Brooks, President

REQUEST FOR PROPOSALS

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

Asphalt Shingle Application Requirements

Sun Windows General Information Sun New Construction Window Installation Instructions

Maintaining Your Roof

Roof Inspection. Summary Report

SECTION PLAYGROUND SURFACING TILES

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

Williamson and Associates, Inc. Report of Building Exterior Condition Evaluation, dated January 2 nd, (68 pages)

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

Commercial Roof Management

Waterproofing Problems: A Simple Explanation, A Simple Solution

How To Build A Roof Tile Deck

WATER LEAKAGE IN GLAZED CURTAIN WALL SYSTEMS:

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The existing roof angle change terminations and flashings when sound and intact can be reused.

How To Compare Roofing Material

How To Replace A Roofing System In Florida

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

metal Duil~ing manufacturers Association

HOT ASPHALT BUILT-UP ROOFING SYSTEMS MORE LAYERS MEANS MORE PROTECTION

The minimum reinforcement for the stem wall is the placement of:

Metropolitan Builders Association Masonry & Concrete Standard

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

Work Experience Form Roofer

SECTION STORM DRAINAGE SYSTEM

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

EPDM System Repair and Cleaning

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Installation Manual for STANDING SEAM ROOFING

Maintenance & repair Solutions

Please read the entire document before purchasing and installing any of these products

City of San Diego, CWP Guidelines

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

COMMERCIAL ROOFING. Learning Objectives. Commercial Roofing Fundamentals May 2, 2012

Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money

Quality Building Products for over 50 Years

Preformed Metal Roofing and Siding

Transcription:

The Harold J. Becker Company, Inc.

It is the mission of The Harold J. Becker Company, Inc. to deliver the absolute best possible quality product at the most efficient cost to our clients, while providing for our employees an environment which gives them an opportunity to achieve a standard of living consistent with their choice of lifestyle for their families. Our customers and employees have the right to ask and expect positive answers to the following three questions: 1. Can I trust you? 2. Do you care about my project and/or concerns? 3. Are you committed to providing the absolute best quality product?

The Harold J. Becker Company - Providing Quality Service Since 1949, The Harold J. Becker Company has provided quality moisture protection services to commercial and industrial customers in the private sector, as well as municipalities, counties, state and federal agencies. We offer a complete line of services, such as: roofing and sheet metal, waterproofing and dampproofing, roof maintenance programs, caulking and masonry restoration. The Harold J. Becker Company serves customers in Ohio, Indiana, Kentucky, Illinois, Michigan, West Virginia, Pennsylvania and Tennessee. Because we are not directly affiliated with any single manufacturer, we have the flexibility to work with our customers to find the best and most cost-effective system for their particular needs and applications.

Roofing and Sheet Metal The Harold J. Becker Company uses the latest in roofing materials. This allows our customers the choice of roofing systems to address the expansion and contraction problems of today s light-weight construction technology. In addition to conventional built-up of roofing systems, we provide new elasto-plastic systems which encompass; elastomers (rubber), plastomers, thermo set, reinforced modified asphalt, and inverted roof membrane assembly systems. Our sheet metal fabrication facilities and skilled and knowledgeable craftsmen use a broad range of state-of-the art equipment. This combination of technology and experience insures that our clients receive the best sheet metal applications possible. The Harold J. Becker Company maintains licensed applicator agreements with the major manufactures of roofing systems, offering 10, 15 and 20 year labor and material warranties. In addition to the manufacturers, The Harold J. Becker Company has an established reputation for standing behind its workmanship. American Electric Power Building, Columbus, Ohio Terrace waterproofing and parking garage roof utilizing conventional 5 ply coal tar pitch with glass and organic felt reinforcement along with a ballasted EPDM system. American Electric Power Building, Columbus, Ohio Illustrates graphic pattern of aggregate ballast by use of aluminum rails and 2 colors of local aggregate.

Huntington National Bank Building, Columbus, Ohio. Inverted roof membrane assembly using reinforced modified asphalt membrane and 2 inch extruded polystyrene insulation. Huntington National Bank Building, Columbus, Ohio. Footprint of building outlined with red granite pavers inlaid with standard concrete pavers over roofing system. Huntington National Bank Building, Columbus, Ohio. Method of elevating precast concrete units by use of EPDM rubber pedestal. Upper Valley Medical Center, Piqua, Ohio Standing seam metal roof system with kynar color coating. Greater Columbus Convention Center, Columbus, Ohio Custom color reinforced batten bar PVC system. Grizzel Middle School, Dublin, Ohio Modified asphalt granual surface roof system.

Caulking and Restoration Caulking and sealant materials available today are more resilient and provide better weatherability than conventional mortar. The Harold J. Becker Company keeps abreast of the latest materials and techniques in this rapidly expanding industry and uses only those which will achieve the best seal for each application. The Harold J. Becker Company provides you, your architects and general contractors complete consultation service on sealant needs and problems and experienced craftsmen to perform the actual sealant work on the job site. A full line of masonry restoration services is available to renew the beauty of your building and increase its lifespan. We remove hydrocarbons and other damaging chemicals, tuckpoint loose and deteriorating mortar joints, caulk perimeter of building openings, and completely check and re-caulk wall flashings and flashing reglets to restore buildings to a like-new condition. County Court House, Xenia, Ohio Twelve year old masonry restoration project involving cleaning, tuckpointing, and sealing of building following extensive tornado damage.

Special Sheet Metal It takes skill, experience, and proper equipment to turn out high quality precision specially sheet metal work. At The Harold J. Becker Company, we pride ourselves on our craftsmen and their talents. Specially sheet metal jobs often require as much attention to appearance as they do to function. The beautiful lines of fine architecture or interior design require skilled hands of experienced sheet metal professionals to achieve the desired results. Let our knowledge, skill and experience help to enhance or maintain the integrity of your new or existing design. Norwick Hotel, Columbus, Ohio Flat seam Terne coated stainless steel roof system. Summit Health Care, Cincinnati, Ohio Stainless steel flat seam metal roof and trim. Summit Health Care, Cincinnati, Ohio Epdm low slope roof and aluminum flat seam wall panels.

Miami Valley Medical Center, Centerville,Ohio Our crews installing a prefabricated aluminum cupola. Miami Valley Medical Center, Centerville,Ohio The finished installation of cupola. Miami Valley Medical Center, Centerville,Ohio Adhered reinforced P.V.C. system with PVC extruded ribs to simulate a standing seam metal roof. Grizzel Middle School, Dublin, Ohio Modified asphalt granular surface roof system.

Waterproofing and Dampproofing Because of escalating building costs, every square foot of space in your building including underground areas must be usable. The Harold J. Becker Company is on the leading edge of the dramatic advances in the waterproofing and dampproofing industry. We offer expert advice and the best quality products to insure dry, serviceable buildings and maximum usage per square foot. Fairmont Church, Kettering, Ohio Hot applied rubberized asphalt water proofing system. Summit Health Care, Cincinnati, Ohio Butyl rubber membrane water proofing system.

Sycamore Glen Retirement, Miamisburg, Ohio New standing seam metal roof system after existing metal roof was removed. Olentangy High School, Powell, Ohio New standing seam metal roof system. Marathon Oil Headquarters, Enon, Ohio Standing seam metal roof system.

The Harold J. Becker Company, Inc. The Harold J. Becker Company, Inc. 3946 Indian Ripple Road P.O. Box 340970 Dayton, Ohio 45434 Phone: 937/426-4951 Fax: 937/429-4521 Toll Free: 800-258-0019 www.hjbecker.com