Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800



Similar documents
Power Meter Series 700

Power Meter Series 800

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Power quality monitoring and analysis with reliability

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Applications. diris_826_a_1_gb_cat

Simple Electrical Utility Cost Allocation Solutions

Quick Connect. quick - simple - efficient.

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Metering Devices IQ Analyzer 6400/6600 Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

A project to optimise quality and energy efficiency must include metering

M2M The measure of efficiency

Energy Management Energy Meter Type EM23 DIN

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

T Substation Maintenance and Commissioning Test Equipment

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Indoor / Outdoor Antenna

How To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Communicate and view data from meters with one simple device

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Electrical Network Management System

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Telephone- and leased line modem for industrial applications TD-36

T200, PTP/IEEE 1588 Grandmaster Clock and

Eaton s E-Series protective relay family

Three-phase monitoring relay CM-PFE

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic Control Devices The European Product Catalogue 2007

Low Voltage Products

Rack mounted telephone- and leased line modem for industrial applications

38 Series - Relay interface modules A

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Electrical Measuring Instruments

38 Series - Relay interface modules A

Electronic Control Devices The European Product Catalogue 2007

Analog signal converters CC-E I/I Current / current isolators

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fluke 3000 FC Series Test Tools Technical Data

TORKEL 820 Battery Load Unit

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Uninterruptible Power Supply

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Application/Connection Examples

Technical note NT588 NT604 NT695 NT782

RM4TG20 three-phase network control relay RM4-T - range V

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

scalable data centre energy management solution

Voltage Regulator SPAU 341 C. Product Guide

Power management. PowerLogic System. Catalogue 2004

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Digital input modules

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Digital multimeters DMG

1.44 kw Programmable DC Power Supplies XLN Series

15 Series - Electronic step relay and dimmer. Features SERIE

3500/62 Process Variable Monitor

Energy Management Power Analyzer Type WM14-96 Basic Version

Transient Recorder and Power Meter With Advanced Power Quality and Communication

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

EARTH LEAKAGE PROTECTION: CONTENTS

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Remote Monitoring and REC 501 Control Unit Product Guide

PCS0100en Persy Control Services B.V. Netherlands

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Arc Terminator Active Arc-Resistant Switchgear

STRATO LED Drivers 70W, Single output

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

MasterINTERFACE 39 Series - Relay interface modules

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

High Power Programmable DC Power Supplies PVS Series

Thyristor-controlled power supplies and battery chargers

Advanced power quality analysis coupled with revenue accuracy in a web compatible meter. PowerLogic ION7550/ION7650 power and energy meters

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

ATC-300 Automatic Transfer Switch Controller

HI/ICMI UVR-1 Universal Voltage Regulator Control

Bulletin 150 SMC Flex Smart Motor Controller Specifications

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

OZW30. Central Unit SYNERGYR

Panorama Electricity meters For reliable values of energy consumption

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Transcription:

Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800

Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit. With its large easy-to-read display, you can monitor all three phases and neutral at the same time. The anti-glare and scratch resistant display features an intuitive interface with context-sensitive menus. A unique white back-light and large digits make it easy to read even in extreme lighting conditions and viewing angles. The PM800 series features as standard an RS 485 communication port, digital input, digital output, THD metering and alarming in the base unit. In addition, the PM820 and PM850 offer custom on-board logging and individual harmonic current and voltage readings. The PM850 is the first meter in this range to offer waveform capture. Applications Panel instrumentation. Sub-billing / cost allocation / bill checking. Remote monitoring of an electrical installation. Basic power quality monitoring. Contract optimisation and load curves. Characteristics Large, easy-to-read display Multiple values displayed at the same time on an anti-glare display featuring a white back-light. Easy to operate Intuitive navigation with context-sensitive menus for easy use. Maximum functionality and minimum size Modbus communications and I/Os integrated in a compact unit (96 x 96 x 70 mm). Harmonics analysis Monitoring of individual harmonic magnitudes and angles to help you troubleshoot your system. On-board memory Critical information stored in non-volatile memory for billing and troubleshooting. IEC 60687 class 0.5S or IEC 61036 class 1 for energy Submetering and cost allocation in 4 quadrants. Modular and upgradable Downloadable firmware and optional modules let you increase the meter capability. Trend curves and short-term forecasting Rapid trending and forecasting of upcoming values for better decision making. Part numbers Power Meter PM810 Power Meter with THD, alarming, I/O PM810MG PM820 Power Meter with harmonics, alarming, I/O, 80 kb logging PM820MG PM850 Power Meter with harmonics, alarming, I/O, 800 kb logging, waveform PM850MG capture Options and accessories 2 relay outputs, 2 digital inputs PM8M22 2 relay outputs, 6 digital inputs PM8M26 2 relay outputs, 2 digital inputs, 2 analog outputs, 2 analog inputs PM8M2222 2

Function and characteristics DB100712 5 1 4 2 3 6 PM800 Series. 1 Control power supply connector. 2 Voltage inputs. 3 Digital input/output. 4 RS485 port. 5 Option module connector. 6 Current inputs. Selection guide PM810 PM820 PM850 General Use on LV and HV systems b b b Current and voltage accuracy 0.1 % 0.1 % 0.1 % Energy and power accuracy 1 % 0.5 % 0.5 % Number of samples per cycle 128 128 128 Instantaneous rms values Current, voltage, frequency b b b Active, reactive, apparent power Total and per phase b b b Power factor Total and per phase b b b Energy values Active, reactive, apparent energy b b b Settable accumulation mode b b b Demand values Current Active, reactive, apparent power Present and max. values Present and max. values b b b b b b Predicted active, reactive, apparent power b b b Synchronization of the measurement window b b b Setting of calculation mode Block, sliding b b b Power-quality measurements Harmonic distortion Current and voltage b b b Individual harmonics - 31 63 Waveform capture - - b Data recording Min/max of instantaneous values b b b Data logs - 2 4 Event logs - b b Trending / forecasting - - b Alarms b b b Time stamping b b b Display and I/O White backlit LCD Display b b b Multilingual: English, French, Spanish b b b Digital input 1 1 1 Digital output or pulse output 1 1 1 Communication RS 485 port 2-wire 2-wire 2-wire Modbus protocol b b b 3

Function and characteristics PB100315 PM800 Series Back View. Electrical characteristics Type of measurement Measurement accuracy Data update rate Input-voltage characteristics Input-current characteristics True rms up to the 63rd harmonic On three-phase AC system (3P, 3P + N) 128 samples per cycle ± 0.075 % of reading + ± 0.025 % of full scale Current and voltage Power PM810 ± 0.5 % of reading + ± 0.025 % of full scale PM820 and ± 0.15 % of reading + ± 0.025 % of full scale PM850 Frequency ± 0.01 Hz from 45 to 67 Hz ± 0.01 Hz from 350 to 450 Hz Energy PM810 IEC 61036 Class 1 PM820 and PM850 IEC 60687 and ANSI C12.20 Class 0.5S 1 s Measured voltage 0 to 600 V AC (direct L-L) 0 to 347 V AC (direct L-N) 0 to 3.2 MV AC (with external VT) Metering over-range 1.5 Un Impedance 2 MΩ (L-L) / 1 MΩ (L-N) Frequency measurement 45 to 67 Hz and 350 to 450 Hz range CT ratings Primary Adjustable from 5A to 327 ka Secondary 1A or 5 A Measurement input range 0 to 10 A Permissible overload 15 A continuous 50 A for 10 seconds per hour 500 A for 1 second per hour Impedance < 0.1 Ω Load < 0.15 VA Control Power AC 110 to 415 ±10 % V AC, 11 VA DC 125 to 250 ±20 % V DC, 6 W Ride-through time 45 ms at 120 V AC Input/outputs Pulse output Static output (6 to 220 ±10 % V AC or 3 to 250 ± 10 % V DC, 100 ma max. à 25 C) 1350 V rms isolation Status Input 1 digital input (24 to125 ±10 % V AC/DC), 5 ma max. burden Mechanical characteristics Weight 0.6 kg IP degree of protection (IEC 60529) IP52 front display, IP30 meter body Dimensions 96 x 96 x 88 mm (meter with display) 96 x 96 x 70 mm (behind mounting surface) Environmental conditions Operating temperature Storage temperature Humidity rating Meter -25 C to +70 C (1) Display -10 C to +50 C Meter + display -40 C to +85 C 5 to 95 % RH at 40 C (non-condensing) Pollution degree 2 Metering category III, for distribution systems up to 347 V L-N / 600 V AC L-L Dielectric withstand As per EN61010, UL508 Electromagnetic compatibility Electrostatic discharge Level III (IEC 61000-4-2) Immunity to radiated fields Level III (IEC 61000-4-3) Immunity to fast transients Level III (IEC 61000-4-4) Immunity to impulse waves Level III (IEC 61000-4-5) Conducted immunity Level III (IEC 61000-4-6) Immunity to magnetic fields Level III (IEC 61000-4-8) Immunity to voltage dips Level III (IEC 61000-4-11) Conducted and radiated emissions CE industrial environment/fcc part 15 class A EN55011 Harmonics emissions IEC 61000-3-2 Flicker emissions IEC 61000-3-3 (1) 65 C if control power is above 305 V AC. 4

Function and characteristics DB100713 Safety Europe CE, as per IEC 61010 U.S. and Canada UL508 Communication RS 485 port 2- wire, up to 38400 bauds, Modbus Firmware characteristics Data Logs Min./max. PM820 and PM850: - 1 billing log - 1 customizable log PM850 only: 2 additional custom logs Worst min. and max. with phase indication for Voltages, Currents, Voltage unbalance, and THD. Min. and max. values for power factor (True and Displacement), power (P, Q, S) and frequency PM800 Series with I/O module. One event log Time stamping to 1 second Trend curves (PM850 only) Four trend curves: 1 minute, 1 hour, 1 day and 1 month: - every second for one minute for the 1-minute curve - every minute for one hour for the 1-hour curve - every hour for one day for the 1-day curve - every day for one month for the 1-month curve Forecasting (PM850 only) Forecasting of the values for the trended parameters for the next four hours and next four days Waveform capture Triggered manually or by alarm, 3-cycle, 128 samples/cycle on 6 user configurable channels Alarms Adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm Four priority levels Response time: 1 second Boolean combination of four alarms is possible using the operators NAND, OR, NOR and XOR on PM850 Digital alarms, e.g. status change of digital inputs Memory available for logging and waveform capture Firmware update Display characteristics Dimensions 73 x 69 mm Languages 80 kbytes in PM820 800 kbytes in PM850 Update via the communication ports Back-lit white LCD (6 lines total, 4 concurrent values) English, French, Spanish 5

Installation and connection Series 800 dimensions DB100564 DB100562 DB100563 Front-panel mounting DB100565 Clearances for multiple Power meters DB100568 DB100569 6

Installation and connection 4-wire connection with 3 CTs and no PT DB100576 3-wire connection with 2 CTs and 2 PTs DB100577 7

Schneider Electric Industries SAS Postal address: Electrical Distribution Communication 38050 Grenoble cedex 9 - France Tel : +33 (0)4 76 57 60 60 As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. PLSED303023EN 2003 Schneider Electric - All rights reserved http://www.schneider-electric.com http://www.schneider-electric.co Design: Ameg Publication: Schneider Electric 07-2003