PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet



Similar documents
Power Meter Series 700

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power Meter Series 800

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power quality monitoring and analysis with reliability

Energy Management Energy Meter Type EM23 DIN

Quick Connect. quick - simple - efficient.

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Panel Meters and Controllers Modular Panel Meter Type EDM 35

38 Series - Relay interface modules A

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

38 Series - Relay interface modules A

Applications. diris_826_a_1_gb_cat

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Telephone- and leased line modem for industrial applications TD-36

Communicate and view data from meters with one simple device

M2M The measure of efficiency

Rack mounted telephone- and leased line modem for industrial applications

PowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet

Uninterruptible Power Supply

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Application/Connection Examples

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Electrical Measuring Instruments

T200, PTP/IEEE 1588 Grandmaster Clock and

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

T Substation Maintenance and Commissioning Test Equipment

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MasterINTERFACE 39 Series - Relay interface modules

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Indoor / Outdoor Antenna

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Energy Management Power Analyzer Type WM14-96 Basic Version

Three-phase monitoring relay CM-PFE

HI/ICMI UVR-1 Universal Voltage Regulator Control

Arc Terminator Active Arc-Resistant Switchgear

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Metering Devices IQ Analyzer 6400/6600 Series

Eaton s E-Series protective relay family

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

PLA 44. Power quality analyzer. User and service manual. BMR trading

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Bulletin 150 SMC Flex Smart Motor Controller Specifications

STRATO LED Drivers 70W, Single output

A project to optimise quality and energy efficiency must include metering

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

MasterINTERFACE 39 Series - Relay interface modules

GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

EARTH LEAKAGE PROTECTION: CONTENTS

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Low Voltage Products

Electronic Control Devices The European Product Catalogue 2007

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Modbus Communications System for Micrologic A, P, and H Trip Units

Simple Electrical Utility Cost Allocation Solutions

80 Series - Modular timers 16 A. Features

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

1.44 kw Programmable DC Power Supplies XLN Series

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Safety technique. Emergency stop module BO 5988 safemaster

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

SURGE PROTECTIVE DEVICES

RM4TG20 three-phase network control relay RM4-T - range V

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Maximum Demand Control

PCS0100en Persy Control Services B.V. Netherlands

Voltage Regulator SPAU 341 C. Product Guide

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

PowerGem Pro Uninterruptible Power Supply

RY2 miniature industrial relays

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Multifunction devices

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Power Supplies 3. SDN-P DIN Rail Series

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Technical Data. back-up time in minutes 100% load % load

FX07 Field Controller

High Power Programmable DC Power Supplies PVS Series

Transcription:

PowerLogic power-monitoring units PM5350 power meter Technical data sheet

Mid-range metering PM5350 Functions and characteristics PE86278 The PowerLogic PM5350 power meter offers all the measurement capailities required to monitor an electrical installation in a single 96 x 96 mm unit extending only 44 mm ehind the mounting surface. With its large display, all three phases and neutral can e monitored simultaneously. The right, anti-glare display features large characters and powerful acklighting for easy reading even in extreme lighting conditions and viewing angles. The meter menus are understood y all, with the availaility of two languages (English/Chinese) included standard in the PM5350. Its compact size and high performance make the PowerLogic PM5350 suitale for many applications. Applications Panel instrumentation. Cost allocation or energy management. Electrical installation remote monitoring. Alarming with under/over, digital status, control power failure, meter reset, self diagnostic issue. Circuit Breaker monitoring and control with relay outputs and whetted digital inputs. Main characteristics Easy to install Mounts using two clips, no tools required. Ultra compact meter with 44mm depth connectale up to 480 VL-L without voltage transformers for installations compliant with category III, as per IEC 61010-1. See specification tale for UL voltage limits. PowerLogic PM5350. Easy to operate Intuitive navigation with self-guided, language selectale menus, six lines, four concurrent values. Two LEDs on the meter face help the user confirm normal operation (hearteat/communications indicator LED: green and other LED orange, customizale either for alarms or energy pulse outputs). Easy circuit reaker monitoring and control The PM5350 provides two relay outputs (high performance) with capaility to command most of the circuit reaker coils directly. In addition, monitored switches can e wired directly to the meter without external power supply. System status at a glance Bright, anti-glare, acklit display plus two LEDs; orange for energy pulse or alarm and green for hearteat/communications indication. IEC 62053-22 class 0.5S accuracy for active energy Accurate energy measurement for cost allocation. Power Quality analysis The PM5350 offers THD and TDD measurements as standard. Total Demand Distortion is ased on a point of common coupling (PCC), which is a common point that each user receives power from the power source. The TDD compares the contriution of harmonics versus the maximum demand load. Load management Peak demands with time stamping are provided. Predicted demand values can e used in asic load shedding applications. Alarming with time stampingover 30 alarm conditions, such as under/over conditions, digital input changes, and phase unalance inform you of events. A timestamped log maintains a record of the last 40 alarm events. Load timer Load timer setpoint adjustale to monitor and advise maintenance requirements. Performance Standard Meets IEC 61557-12 PMD/S/K70/0.5. 2

Mid-range metering PM5350 Functions and characteristics (cont.) PE86323 General Use on LV and MV systems Basic metering with THD and min/max readings Instantaneous rms values Current Total, Phases and neutral Voltage Total, Ph-Ph and Ph-N Frequency Real, reactive, and apparent power Total and per phase Signed True Power Factor Total and per phase Signed, Four Quadrant Displacement PF Total and per phase Signed, Four Quadrant Unalanced I, VL-N, VL-L PE86324 PM5350 meter parts A Retainer clips. B Control power supply connector. C Voltage inputs. D Digital outputs. E Rs485 port (COM1). F Digital outputs. G Optical revenue switch. H Current inputs. Energy values Accumulated Active, Reactive and Apparent Energy Demand values Current average Active power Received/Delivered; Net and asolute; Present, Last, Predicted, Peak, & Peak Date Time Present, Last, Predicted, Peak, & Peak Date Time Reactive power Present, Last, Predicted, Peak, & Peak Date Time Apparent power Present, Last, Predicted, Peak, & Peak Date Time Peak demand with timestamping D/T for current & powers Demand calculation Sliding, fixed and rolling lock, thermal Synchronization of the measurement window Other measurements I/O timer Operating timer Active load timer Alarm counters Power quality measurements THD, thd (Total Harmonic Distortion) I,VLN, VLL TDD, thd (Total Demand Distortion) Data recording Min/max of instantaneous values, plus phase identification Alarms with 1s timestamping Standard 29; Unary 4; Digital 4 Alarms stored in non-volatile memory 40 events Inputs/Outputs Digital inputs 4 (DI1, DI2, DI3, DI4) Digital outputs 2 relay outputs (DO1, DO2) Display White acklit LCD display, 6 lines, 4 concurrent values IEC or IEEE visualization mode Communication Modus RTU, Modus ASCII, Jus Protocol Firmware update via RS485 serial port (DLF3000 via the Schneider Electric wesite: www.schneider-electric.com) Stored in non-volatile memory 3

Mid-range metering PM5350 Functions and characteristics (cont.) PE86292 Electrical characteristics Type of measurement Measurement accuracy True rms up to the 15th harmonic on three-phase (3P, 3P + N) 32 samples per cycle, zero lind Current, Phase (1) ±0.30% Voltage, L-N (1) ±0.30% Power Factor (1) ±0.005 Power, Phase IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A nominal CT when I > 0.15A) ±0.5% from 0.25 A to 9.0 A at COS φ = 1 ±0.6% from 0.50 A to 9.0 A at COS φ = 0.5 (ind or cap) Frequency (1) ±0.05% Real Energy IEC 62053-22 Class 0.5S; IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A nominal CT when I > 0.15A) ±0.5% from 0.25 A to 9.0 A at COS φ = 1 ±0.6% from 0.50 A to 9.0 A at COS φ = 0.5 (ind or cap) IEC 61557-12 Class 0.5 Reactive Energy IEC 62053-23 Class 3, IEC 61557-12 Class 2 For 5 A nominal CT (for 1 A nominal CT when I > 0.15A) ±2.0% from 0.25 A to 9.0 A at SIN φ = 1 ±2.5% from 0.50 A to 9.0 A at SIN φ = 0.5 (ind or cap) 1 second nominal (50/60 cycles) Data update rate Input-voltage VT primary 1.0 MV AC max, starting voltage depends on VT ratio. U nom 277 V L-N Measured voltage with IEC: 20 to 690 V AC L-L; 20 to 400 V AC L-N overrange & Crest Factor UL: 20 to 300 V AC L-L Permanent overload 700 Vac L-L, 404 Vac L-N Impedance 10 M W Front screen view of PM5350. Frequency range 45 to 70 Hz Input-current CT ratings Primary Adjustale 1 A to 32767 A Secondary 1A, 5 A nominal Measured voltage with 5 ma to 9 A overrange & Crest Factor Withstand Continuous 20 A,10 sec/hr 50 A,1 sec/hr 500 A Impedance < 0.3 mw Frequency range 45 to 70 Hz Burden < 0.024 VA at 9 A AC control Operating range 85-265 V AC power Burden 4.1 VA / 1.5 W typical, 6.7 VA / 2.7 W max at 120 V AC 6.3 VA / 2.0 W typical, 8.6 VA / 2.9 W max at 230 V AC 9.6 VA / 3.5 W maximum at 265 V AC Frequency 45 to 65 Hz Ride-through time 100 ms typical at 120 V AC and maximum urden 400 ms typical at 230 V AC and maximum urden DC control Operating range 100 to 300 V DC power Burden 1.4 W typical, 2.6 W maximum at 125 V DC 1.8 W typical, 2.7 W maximum at 250 V DC 3.2 W maximum at 300 V DC Ride-through time 50 ms typical at 125 V DC and maximum urden Real time clock Ride-through time 30 seconds Digital output Numer/Type 2 - Mechanical Relays Output frequency 0.5 Hz maximum (1 second ON / 1 second OFF - minimum times) Switching Current 250 V AC at 2.0 Amps, 200 k cycles, resistive 250 V AC at 8.0 Amps, 25 k cycles, resistive 250 V AC at 2.0 Amps, 100 k cycles, COSΦ=0.4 250 V AC at 6.0 Amps, 25 k cycles, COSΦ=0.4 30 V DC at 2.0 Amps, 75 k cycles, resistive 30 V DC at 5.0 Amps, 12.5 k cycles, resistive Isolation 2.5 kvrms Status Digital Voltage ratings ON 18.5 to 36 V DC, OFF 0 to 4 V DC Inputs Input Resistance 110 k W Maximum Frequency 2 Hz (T ON min = T OFF min = 250 ms) Response Time 10 ms Isolation 2.5 kvrms Whetting output Nominal voltage 24 V DC Allowale load 4 ma Isolation 2.5 kvrms (1) Measurements taken from 45 Hz to 65 Hz, 0.5 A to 9 A, 57 V to 347 V & 0.5 ind to 0.5 cap power factor with a sinusoidal wave. 4

Mid-range metering PM5350 Functions and characteristics (cont.) Mechanical characteristics Weight 250 g IP degree of protection (IEC 60529) IP51 front display, IP30 meter ody Dimensions W x H x D 96 x 96 x 44 mm (depth of meter from housing mounting flange) 96 x 96 x 13 mm (protrusion of meter from housing flange) Mounting position Vertical Panel thickness 6.35 mm maximum Environmental characteristics Operating Meter -25 C to 70 C temperature Display -20 C to +70 C (Display functions to -25 C with reduced performance) Storage temp. Meter + display -40 C to +85 C Humidity rating 5 to 95 % RH at 50 C (non-condensing) Pollution degree 2 Altitude 3000 m max. Electromagnetic compatiility Electrostatic discharge IEC 61000-4-2 (2) Immunity to radiated fields IEC 61000-4-3 (2) Immunity to fast transients IEC 61000-4-4 (2) Immunity to impulse waves IEC 61000-4-5 (2) Conducted immunity IEC 61000-4-6 (2) Immunity to magnetic fields IEC 61000-4-8 (2) Immunity to voltage dips IEC 61000-4-11 (2) Radiated emissions FCC part 15 class A, EN 55011 Class A Conducted emissions FCC part 15 class A, EN 55011 Class A Harmonics IEC 61000-3-2 (2) Flicker emissions IEC 61000-3-3 (2) Safety Europe e, as per IEC 61010-1 U.S. and Canada culus as per UL61010-1, IEC 61010-1 (2nd Edition) Measurement category (Voltage and current inputs) Per IEC 61010-1: CAT III, 277 V L-N / 480 V L-L (1) nominal; CAT II 400 V L-N / 690 V L-L (1) nominal Per UL 61010-1 and CSA C22.2 No. 61010-1: CAT III, 300 V L-L Overvoltage Category (Control power) CAT III Dielectric As per IEC 61010-1 Doule insulated front panel display Protective Class II Communication RS 485 port 2-Wire, 9600,19200 or 38400 aud, Parity - Even, Odd, None, 1 stop it if parity Odd or Even, 2 stop its if None; Modus RTU, Modus ASCII (7 or 8 it), JBUS Firmware and language file update Isolation Human machine interface Display type Resolution 128 x 128 Backlight Viewale area (W x H) Keypad Indicator Hearteat / Comm activity Update via comunication port using DLF3000 software 2.5 kvrms, doule insulated Monochrome Graphics LCD White LED 67 x 62.5 mm 4-utton Green LED Energy pulse output / Active alarm indication (configurale) Type Optical, amer LED Wavelength Maximum pulse rate (1) V L-L is limited to 700 V AC (2) As per IEC 61557-12 590 to 635 nm 2.5 khz 5

Power-monitoring units PM5350 Power Meter Installation and connection Rear of meter - open PE86279 Rear view retainers - installation PE86274 For detailed installation instructions see the product's Installation guide. 6

Power-monitoring units PM5350 Power Meter Installation and connection (cont.) Rear view retainers - users PE86275 For detailed installation instructions see the product's Installation guide. RS485 daisy-chain connection PE86276 18 19 20 (-) D0 (+) D1 If the power meter is the first device on the daisy chain, connect it to the host device using a RS232 to RS422/RS485 converter. If the power meter is the last device on the daisy chain, terminate it with the terminator provided. The terminal s voltage and current ratings are compliant with the requirements of the EIA RS485 communications standard. For detailed installation instructions see the product's Installation and reference guides. 7

Power-monitoring units PM5350 Power Meter Installation and connection (cont.) NOTE: This is a small sample of wiring diagrams - many more system types are supported. Single Phase L-L 2 Wire 1 CT wiring diagram PE86253 PM5350 input/output capailities The PM5350 has four (4) digital inputs and two (2) mechanical relay outputs. The digital inputs have two (2) operating Modes: Normal and Demand Sync. The relay outputs have three (3) operating modes: External Control (default), Alarm, and Demand Sync. When configured in Alarm mode, the digital output can e controlled y the meter in response to an alarm condition. PE86277 PM5350 DO1 13 14 DO2 15 16 18 D0 19 D1 20 + 21 -/C DI1 DI2 DI3 DI4 22 23 24 25 26 + - LOAD LOAD (1) Digital inputs and outputs are not SELV rated. (2) Overcurrent protective device must e rated for the short-circuit currents at connection point. 8

Power-monitoring units PM5350 Power Meter Installation and connection (cont.) NOTE: This is a small sample of wiring diagrams - many more system types are supported. 3 Phase 3 Wire 2 VT 1 CT wiring diagram PE86254 3 Phase 4 Wire WYE 3 VT 1 CT wiring diagram PE86255 9