Routefinder Testing and reporting for emergency lighting systems



Similar documents
LED & Maintenance Factors

The intelligent DALI Emergency Lighting Monitoring System with One Click Commissioning

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

POWERED BY BLUE EARTH

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

Functional Specification Document

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Energy Communication Unit (ECU)

VTO6xxx. IP door stations. User manual

USB-500 Series Stand-Alone, Low-Cost Data Loggers

SNMP Web Management. User s Manual For SNMP Web Card/Box

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Energy Communication Unit (ECU)

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

NGSS Data Consolidator (DC)

HOW-TO-GUIDE. Installer Service Tool: Downloading Data and Event Logs for the Eltek Theia

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

YM.SW.105.UM.EN.D00REV FH11 Fri Jul 25 16:00: Page 1

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise.

Advanced Central Monitoring. User Guide

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

UniOP epad33 and epad33t

FIREDEX Conventional Fire Panels

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

EnvisionManager. Lighting Control System Software Suite Increase lighting performance and reduce operating costs

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

User Manual. EtherUSB

Configuring the WT-4 for Upload to a Computer (Infrastructure Mode)

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

KX-NTV150 IP communication camera KX-NTV160 IP video door phone. Where voice meets vision

IntesisBox KNX Mitsubishi Heavy Industries AC

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

MONITORING ELECTRICITY, WATER, SOLAR AND GAS

3.5 EXTERNAL NETWORK HDD. User s Manual

Configuring the WT-4 for ftp (Ad-hoc Mode)

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Disclaimers. Important Notice

L-1 Fingerprint Reader Solutions. V-Flex 4G

sat-nms SMU Signal Management Unit

interoperability flexibility scalability Helvar Router Systems P e o p l e I n n o v a t i o n s S o l u t i o n s

VEGA Analogue Addressable Control Panels

HyperAccess Access Control System

CMP-102U. Quick Installation Guide

Emerson Smart Firewall

Exploring the world of Canon EOS photography. EOSmagazineQ. from July-September Wireless world Communication without cables

UPS Network Interface. Quick InstallationGuide

PCS300 Universal IP Reporting Module V1.0

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Using MagicQ with the Capture visualiser

High voltage tester HA 1800 Table-top device

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

USB-500 Series Low-Cost Data Loggers and Accessories

Electric Vehicle Charging Solutions

Configuring the WT-4 for ftp (Infrastructure Mode)

USB-500/600 Series Low-Cost Data Loggers and Accessories

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

NTP Receiver/Software Installation Guide

Process Alarm Solutions

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Uninterruptible Power Supply

Data Loggers for Real Time Temperature Monitoring - WiFi

A C C E S S C O N T R O L S Y S T E M

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

Standalone recorder instruction

NETWORK ENABLED EQUIPMENT MONITOR

Network Video Recorder. Operation Manual

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Quick Start Turning on the Tablet PC for the First Time

Quick Installation Card

1. Introduction Fixture exterior view Connecting the Robe Universal Interface Software update of the fixture...

Fleet Tracking Capability. FX 500 / FX 250 FleetBroadband Satellite Terminal

FXM Communication Manual

HCR3.2/.. Chipcard reader HOTEL SOLUTION

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

PXM20-E. Operator unit DESIGO PX

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

TMS TANK MANAGEMENT SYSTEM

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

Cisco TelePresence VCR MSE 8220

Chapter7 Setting the Receiving PC for Direct Upload. Setting the Receiving PC for Direct Upload For Windows For Macintosh...

ShareLink 200 Setup Guide

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Solid as a Rock etop 300/400

Fire. The Fire Installers Mate. A guide to fire alarm systems design

INS580. Apps for Android. Android is a trademark of Google Inc.

R-Win. Smart Wireless Communication Management System

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

3500/22M Transient Data Interface

Transcription:

Routefinder Testing and reporting for emergency lighting systems

Routefinder brings simplicity in both operation and installation to the testing and monitoring of an emergency lighting system. Controlled from a touchscreen, Routefinder can monitor and report on any DALI addressable emergency lighting, without the need for complex infrastructure. The simple and intuitive Graphical User Interface provides real time access to emergency testing and reporting as well as clear visual notification of faults.

Routefinder Routefinder is a standalone, testing, monitoring and reporting DALI emergency system. Simple to install, intuitive and user-friendly, Routefinder works around an innovative touchscreen panel that s fitted to the wall. This touchscreen has an integral Graphical User Interface that automatically communicates the status of the system to the user through colour coded graphics. All OK A green tick indicates the emergency devices on the system are functioning correctly. Thus the lighting in place will work if an emergency arises. Fault(s) found A red cross indicates that one or a number of emergency devices on the system are not functioning correctly. Thus the lighting in place may not work if an emergency arises. In Action Completely scalable, Routefinder is suitable for small to medium one floor applications right up to large networked multi-floor applications. One panel can be linked to up to 128 DALI emergency devices over 2 DALI subnets. These devices could be LED or fluorescent luminaires, exit signs or enclosed emergency units. As well as being addressed individually or altogether, every device on the system can belong to up to 16 group assignments. Group assignments can be used to apply emergency tests to predefined areas of a building, and can be reconfigured at any time, for example to accommodate changes in building usage without the need for re-wiring. Typical small to medium site configuration Routefinder Specification One Routefinder panel, linked to 27 DALI EM inverters; - 15 x Recessed 600sq luminaires with integral COMEPS in open office - 7 x Surface luminaires with integral COMEPS in corridors - 3 x Standalone COMEPS emergency units in cellular offices - 2 x COMEPS Exit Signs at exits Reporting software is included with touchscreen to enable downloading of reports through a Windows computer s USB port Any COMEPS enabled emergency luminaire Any COMEPS enabled luminaire

Typical large networked site configuration Routefinder Ethernet Switch Desktop PC Specifications One Routefinder touchscreen on each floor of the building; each panel linked to 27 DALI EM inverters on each floor Three touchscreens are linked to each other and connected to a LAN via an Ethernet switch Touchscreens can be accessed remotely via Windows computer with software licence (supplied separately) Ensuring compliance Routefinder has been designed to conform with the international standard for DALI protocol, IEC 62386. The system conducts function and duration testing at times defined by the user. The automatic testing is in accordance with IEC 62034 / BS5266 / EN50172. Test logs and reports are stored for up to 4 years. Any COMEPS enabled exit sign For compliance with other standards, please consult Whitecroft Controls Department.

routefinder Testing and reporting for emergency lighting systems Information Routefinder is a DALI emergency test and monitoring system, suitable for simple emergency installations or for large networked systems. Compatible with all approved Whitecroft DALI emergency (COMEPS) enabled products.* Via the intuitive touchscreen and integrated software, the Routefinder system provides a comprehensive picture of the historical and real-time status of the emergency lighting installation. Automatic status notifications are logged by the system whenever a fault or test failure is detected that could compromise the safety of the system. A full record of system status is available at any time. Routefinder can be utilised in one or multiple areas, depending on the needs of the application. Multiple Routefinder touchscreens can be networked together to remotely monitor larger systems using an Ethernet switch and additional software (supplied separately). *The presence of COMEPS emergency is denoted in the product part code by suffix /EP. To check compatibility of a product with the Routefinder system, please contact Whitecroft Technical Desk. Specification Touchscreen user interface Intuitive colour-coded display of system status Integrated network and power connections Recessed and surface-mount housings supplied, outer bezel finished white (minimum void depth of 47mm for recessed) Ethernet port for programming and networking Password-protected engineering mode View and print reports via the USB connection on the front of the panel using reporter software included Compatible with all approved COMEPS products Auto power save mode IP20 System commissioning is required Order Codes Version LCD touchscreen panel Central monitoring software licence (For networking multiple panels together) Dimensions H 1 L 1 H RFDLCDW RFDMON L Electrical Input voltage 230V AC +/- 10% Ambient 0 to +50 C Up to 128 devices per panel across 2 subnets (64 devices per DALI subnet) Output voltage 24V DC Replaceable CR1200 3V lithium battery (3 year life) Data transfer via Ethernet TCP/IP USB programming port 250mA limit per subnet W 1 W L W H L 1 W 1 H 1 KG 156 11 92 146 48 86 0.3 Cut Aperture: 133 x 75 To Specify DALI emergency LCD touchscreen based test and monitoring system. Fully addressable LED emergency lighting points. Touchscreen with programmable interface compatible with all approved COMEPS products as Whitecroft Lighting Routefinder

Lighting, design, controls: Total Project Solutions UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX T +44 (0)8705 087 087 F +44 (0)8705 084 210 email@whitecroftlight.com Online whitecroftlighting.com Rep. Ireland Office Fagerhult Ltd F1 Calmount Park Ballymount, Dublin 12 Ireland T +353 (0)1 426 0200 F +353 (0)1 429 9606 info@fagerhult.ie www.fagerhult.ie Middle East Office Fagerhult Middle East P.O. Box 126287 Dubai United Arab Emirates T +971 (0)4 3297120 F +971 (0)4 3297130 info@fagerhult.ae www.fagerhult.ae London Customer Centre Whitecroft Lighting Ltd 102-108 Clerkenwell Road London EC1M 5SA T +44 (0)8705 087 087 F +44 (0)8705 084 210 Glasgow Customer Centre Whitecroft Lighting Ltd First Floor, Pavilion 6 321 Springhill Parkway Glasgow Business Park Glasgow, G69 6GA T +44 (0)8705 087 087 F +44 (0)8705 084 210