DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS



Similar documents
Quick wins for energy savings in buildings

DATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

Camfil Farr Technical Services Bulletin

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

1/15/2013. HVAC Maintenance Repair or Replace & Planned Replace Initiative. Reduce Operating Costs. Improve Comfort / Process Conditions

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

HVAC Air Systems. Recirculation Air System Types

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Green Data Centre Design

Laminar Flow Cabinets

HVAC Design Requirements

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Ultra-Web High Efficiency Nanofiber Filters

Element D Services Heating, Ventilating, and Air Conditioning

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

Extend the Life of Your Data Center By Ian Seaton Global Technology Manager

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT. READ ONLY

Data Centre Energy Efficiency Operating for Optimisation Robert M Pe / Sept. 20, 2012 National Energy Efficiency Conference Singapore

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Glossary of Heating, Ventilation and Air Conditioning Terms

PRESENTATION BY: MIKE BURT AIR FILTER SOLUTIONS INC. DENVER, COLORADO

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

Dehumidification Frequently Asked Questions

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Rack Hygiene. Data Center White Paper. Executive Summary

White Paper: Free Cooling and the Efficiency of your Data Centre

Greening Commercial Data Centres

Datacenter Efficiency

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

Drives and motors. A guide to using variable-speed drives and motors in data centres

SAM HOUSTON STATE UNIVERSITY

Mechanical Rooftop Custom Capabilities

Power and Cooling for Ultra-High Density Racks and Blade Servers

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Basics of HVAC Cleaning

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Advanced Filtration Media.

Screw Compressors ESM Fixed Speed & VS Variable Speed

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Gas-Phase Filtration. Advanced Solutions for the Removal of Airborne Particulate and Gaseous Contaminants. Better Air is Our Business

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Air Conditioners. A cool, comfortable solution to take you to a higher standard of comfort. READ ONLY

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.

ENHANCED LABORATORY HVAC SYSTEM

Ultra-Filter. Compressed Air Filter. DF Series

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

APC APPLICATION NOTE #112

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Specialty Environment Design Mission Critical Facilities

How To Improve Energy Efficiency In A Data Center

1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

What to Know When Considering a Cleanroom. by Simplex Technical Staff

Leveraging the Power of Intelligent Motor Control to Maximize HVAC System Efficiency

HVAC Checklist - Long Form

Medical Air Systems: Scroll

Cooling Strategies for IT Wiring Closets and Small Rooms

MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS

1.2 Refrigerant Equipment. General

Clean air solutions FOOD & BEVERAGE INDUSTRY

NetApp Data Center Design

Benefits of. Air Flow Management. Data Center

DOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers

Air Conditioners A COOL, COMFORTABLE SOLUTION TO TAKE YOU TO A HIGHER STANDARD OF COMFORT.

Using Portable Spot Air Conditioners in Industrial Applications

Analysis of data centre cooling energy efficiency

Cooling Strategies for IT Wiring Closets and Small Rooms

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

National Grid Your Partner in Energy Solutions

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Energy Management Services

Demand Based Static Pressure Reset Control for Laboratories

Residential Duct Systems for New and Retrofit Homes

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Transcription:

DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric tool that measures and tracks where and how improvements can be made in efficiency performance of the electrical and mechanical infrastructure the lower the ratio, the better the efficiency. A PUE ratio can be dramatically lowered by the reduction of electrical energy draw, or fan energy in the data center s cooling system. The efficiency and energy curves of fans used in the cooling systems is far from constant. There can be a difference of 30% or more between peak and low efficiency in fan working range. Filter pressure drop is the driving force behind fan energy expenditures. If low cost filters are installed, pressure drop will cause the system to lose efficiency, sending fan energy costs soaring, which in turn will show a rise in the PUE ratio. Regardless of the type of cooling or AHU system installed in a facility, to manage pressure drop and maintain as close to peak fan efficiency as possible, it s imperative to evaluate the choice of filters used. When you consider the number of filters needed annually in a system, the guaranteed efficiency and Total Cost of Ownership (TCO) should be the key drivers for determining which filter selection is the best solution. The majority of the energy consuption in your facility is the data center. This chart represents the energy survey of a 21-story office building. It s a fact Data Centers consume an exorbitant amount of energy. With Camfil, data centers have documented six figure savings in total cost of ownership. Camfil s Farr 30/30, Durafil ES 2 and Hi-Flo ES filters have Energy Cost Index (ECI) ratings of five stars the highest performance rating available. Camfil uses a proprietary blend of fine fibers that uses a mechanical particle capture principle which does not require an electret charge. This offers the longest life and lowest average pressure drop while in service over the life of the filter...guaranteed! Low cost, coarse fiber filters, which incorporate an electret charge to operate, can drop in efficiency and increase in pressure drop in a short period of time resulting in increased fan energy consumption and shorter filter life. Although the upfront cost for these filters may be lower, the Total Cost of Ownership (TCO) is higher because they are on the negative side of Life Cycle Cost (LCC) values when compared to the fine fiber media used in Camfil products. Camfil s low average pressure drop filters allow AHUs and fans to be downsized, saving operating costs and capital costs on initial installation. Conversely, if a system isn t optimized at design, Camfil filters can replace substandard filters, or can be retrofitted with FastFrames or Multi-Track hardware for short term payback. These are just some of the factors that are considered in Camfil s LCC Software (see page 3). Camfil offers a free LCC analysis which is performed by our exclusive distributor in your area. Camfil s longer lasting, fine fiber filters extend equipment life and reduce maintenance. Data firms consume energy Camfil has documented significant energy savings for our data center customers, in some cases, by as much as six figures annually. According to DOE statistics, the data center electricity usage of 30 billion kilowatt hours, in 2001, soared to 100 billion kilowatt hours by 2013. Analysts project this figure will quadruple over the next three years. Business enablement platforms bear increasing demands for cloud access this drive will push mega data center production to jump eight times from the standards of today by the year 2018. FARR 30/30 With its industry leading 5-Star ECI Rating, the Camfil Farr 30/30 sets the standard for medium efficiency air filtration. When used as a prefilter, a stand-alone HVAC filter, or as the main filter in custom data room air conditioning units, the Farr 30/30 will remove nuisance dusts and staining particles, and increase the life of downstream final filters by removing contaminants that shorten the life of final filters. Using a mechanical efficiency to provide MERV 8 and MERV 8-A performance levels, the Farr 30/30 will maintain its efficiency throughout the life of the filter. LCC SOFTWARE The selection of air filters for data processing facilities is a critical decision when considering filter effectiveness in providing a clean environment. An almost equally critical factor is what a filter will cost over its lifetime in the system, or its Total Cost of Ownership (TCO). There are hidden costs to air filters, with energy usage at the top of the scale. This is followed by associated labor to service the filters, disposal costs and carbon footprint. Camfil can predict your TCO using our proprietary Life Cycle Costing (LCC) software. It can also predict the optimum filter change-out point to optimize energy usage and filter life based upon the actual operating parameters of your facility. DURAFIL ES 2 The Durafil ES 2 offers high efficiency particle removal down into the sub-micron particle range to protect the most sensitive semiconductor and electromechanical equipment from contamination. Its glass mat media maintains efficiency throughout the life of the filter and its increased media area ensures maintained low pressure drop and longer filter life. The Durafil ES 2 can save 40% or more in energy expenditures when compared to competitive products. Inputs include operating velocities, filter performance data pulled from a comprehensive information database of competitive filters, energy cost per kwh, number of hours of operation, labor cost projections, disposal costs and information related to total carbon footprint. Your local Camfil representative can run a data center specific LCC analysis at your convenience to see how you can save thousands, even tens of thousands of dollars a year. HI-FLO ES Life Cycle Costing software is a proprietary modeling tool developed by Camfil that allows users to evaluate and optimize air filter selection and change out points to reduce total cost of ownership. The Hi-Flo ES uses a Camfil-exclusive high loft micro fine glass media to capture particles down into the sub-micron particle range to protect data center equipment from contamination. The Hi-Flo ES may be used as the only filter in a single-stage system eliminating pressure drop and service requirements associated with two-stage filtration systems that require a prefilter. Available in MERV 11, MERV 13, MERV 14 and MERV 15, its MERV and relative MERV-A testing values are equivalent ensuring that performance is maintained throughout filter life. 2 Camfil Clean Air Solutions Camfil Clean Air Solutions 3

OPTIMIZATION ENERGY SAVINGS Outside Air Intake Plenum Mixing Area Farr 30/30 Fine Fiber And Durafil ES2 Filters Cooling Coils Condensing Coils Fan Arrays Exhaust Air Plenum Supply Air Plenum Misting Coils Supply Air Shaft Misting Eliminator Exhaust Fans & Louvers In most data center applications, Camfil recommends MERV 13 filters for the best balance of particle removal efficiency, low energy expenditures and a long filter life. Depending upon individual facility considerations, common configurations may include the Hi-Flo ES as the only filter stage or a Camfil Farr 30/30 with a Durafil ES 2 for two-stage designs. Data centers have critical cleanliness requirements, which is why Camfil recommended filters also have a MERV-A equivalent to their published MERV this ensures sustained filter performance over the entire life of the filters. Coarse fiber, or synthetic media products, lose efficiency over time often sacrificing filter efficiency resulting in a dirtier environment. Outside Air Louvers & Dampers Return Air Dampers Exhaust Air Ceiling Plenum Server Racks Hot Aisle Containment Panels 5-Star ECI Rating Camfil s filters are rated as 5-Star filters through the Energy Cost Index (ECI) program. Based upon a five-star scale, the Energy Cost Index is an indicator of what a filter will cost over its lifetime. The best rating five stars indicates that the filter is the most energy-efficient, longest lasting filter available. Farr 30/30 Durafil ES 2 Hi-Flo ES No PreFilter Necessary FASTFRAME The Camfil FastFrame for built-up air filter banks does not require cumbersome fasteners or clips to install filters into the frame. It accepts any headered air filter, including pads, pleats, bags, boxes and v-bank filters. It can also be used for two-stage filtration applications. Air bypass is eliminated as the air filters snap into place against a replaceable frame-to-filter seal ensuring less than ½ of 1% leakage across the filter and frame combination all of the air seen by the system will be treated by the system. The FastFrame is available in 24-inch by 24-inch, 12-inch by 24-inch, 20-inch by 24-inch and 20-inch by 20-inch sizes to accommodate a variety of airflow requirements. Existing systems can be retrofitted with Fast Frame or Multi-Track hardware. 4 Camfil Clean Air Solutions Camfil Clean Air Solutions 5

ON-SITE TESTING CAMFIL CAMCLEANER The Camfil CamCleaner provides clean air to data center areas that may require a higher level of cleanliness than the rest of the facility. It is also used to supplement HVAC systems that lack clean air performance required to maintain the data center s integrity. CamCleaner is available as a free-standing portable unit, or in a horizontal configuration that suspends within a room or connects to a ducted air distribution system above a ceiling. Available in 2000 or 4000 cfm airflow capacities, the CamCleaner accepts a variety of air filter efficiencies from MERV 8 prefiltration, various configurations and high efficiency final filtration, to HEPA level filtration for removing ISO cleanroom level contaminants. The freestanding portable unit includes carbon filtration capabilities for facilities that may have corrosive gas or odor problem concerns. LEADING THE WAY IN CLEAN AIR TECHNOLOGY The solution is clear protect your best in class technology with ours. Camfil is the global leader in clean air technology and air filtration products. We are the world s largest designer and manufacturer of air filters and related products, with over twenty six manufacturing facilities, six research and development sites, and over sixty five sales offices worldwide. Camfil employs over 60 global engineers and PhDs focused on product development more than all of our competitors combined. This ensures our products deliver performance and cost savings unachievable by other brands. Camfil is the only company with multiple air filter testing labs set to perform ASHRAE guideline air filter tests, and we are the only company with the equipment to perform ASHRAE 52.2 2007 Appendix J tests. We use this foundation to develop our products with the focus on premium performance. Servicing and supporting a broad spectrum of industries and administrations, Camfil takes pride in the fact that our products are of the highest quality, with the longest life, as well as the lowest operating and maintenance costs. We strive to develop and create products that well exceed industry standards and requirements. Strict monitoring, ISO certified quality control manufacturing processes and frequent product sample testing in our world-class testing facilities ensure that our customers receive industry leading product performance. Camfil is the world s largest designer and manufacturer of air filters with 26 manufacturing facilities around the globe. CAMFIELD LAB CAMTESTER II CamTester II, Camfil s mobile energy auditor with integrated fan, flow controller, and pressure transducer is used to measure filter performance on all styles of HVAC air filters. The remote display measures and shows the set air flow rate, the cubic feet per minute, the air filter s static pressure, and the energy consumption of the integrated fan in watts. 6 Camfil Clean Air Solutions Camfil s CamField Lab sets a higher standard for users to evaluate one air filtration product versus another, at the user s site, under their unique conditions by testing individual air filters either Camfil filters or competitors filters. Air quality managers can evaluate filters for particle size versus efficiency, using instruments that provide particle counts in individual bands that includes micron sizes from 0.3 to 0.5, 0.5 to 0.7, 0.7 to 1.0, 1.0 to 2.0 and 2.0 to 5.0., and can also provide cumulative totals from one selected particle size and larger. Detailed reports help you to attain data that may be critical to analyze factors such as temperature, humidity and airflow histories. Camfil Clean Air Solutions 7

CAMFIL is the world s largest and leading manufacturer of filters and clean air solutions. For over 50 years Camfil has been the global leader for air purification solutions. Our mission is clear. We are dedicated to providing exceptionally high quality air filtration for the benefit of human health, commercial processes, and environmental protection. There s a science behind clean air. Our CamField Mobile Lab, In-situ testing and Life Cycle Cost analysis software will help you determine the best performance outcome and the best value for your data center facility. Call your Camfil representative today. www.camfil.us For further information please contact your nearest Camfil office.