Certificate of Compliance



Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

How can a charging station for electric vehicles be set up simply and safely?

Electronic overload relay EF19 and EF45

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

CUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH _0_000

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Technicaldata General

Catalog January. Heavy industrial power applications Motor contactors and starters

Products and solutions for lifting systems

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Electronic overload relay EF65, EF96 and EF146

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

3RV Motor Starter Protectors up to 100 A

Products and solutions for pumping, irrigation and piping

8146/5 Series Breaker Panelboards

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

Circuit Breakers. NRC Series. NRC Series

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

RY2 miniature industrial relays

Tmax MCCBs. Molded case circuit breakers. Tmax

D-Line Contactors, Overload Relays and Accessories

CQM1-SF200/CS1W-SF200

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

VL circuit breakers. Information guide.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Protection Equipment

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

PSR The compact range Description

Circuit Breakers. Next Generation of Protection Capabilities

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Bulletin 1489 Circuit Breakers. Selection Guide

Relés e Contatores de Estado Sólido SIRIUS

Data Sheet. Electro-mechanical counters Hengstler 800 series

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

HERZ-Thermal Actuators

Rotary Disconnect Switch Specifications

ABB Inc. April 19, 2011 Slide 1

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Bolted contact switches. Pringle switches

Motor circuit-breakers

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

The power distribution board that sets new standards

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Arc Terminator Active Arc-Resistant Switchgear

Safety Relays ESM/ESM-F

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Manual Motor Starter MS 116 up to 16 A Technical Data

leader in voltage regulators since 1946

Unified requirements for systems with voltages above 1 kv up to 15 kv

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Section 5. IEC Power Devices. Control Catalog 5-1

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Actuator-Sensor-Interface

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Vanguard DC /DC-Technology - worldwide -

BETA Protecting SITOR Semiconductor Fuses

Secondary Unit Substations

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Safety automation solutions

Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors

Sentron Series Circuit Breakers

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

4 Posiflow Proportional Solenoid Valves

The Interaction of Contactors with PLCs

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

How To Select A Solid State Relay For A Three Phase Resistive Load

Alternate Methods to Short Circuit Breaker Coordination

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

3K Load-Break Switches The Program for Safety and Performance. sentric

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

INTEGRAL Self-Protected Combination Motor Controllers

The following components are common to most cubicles; this example is an ABB HK cubicle.

Products and solutions for machine builders (OEM) 100% electricity

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Schneps, Leila; Colmez, Coralie. Math on Trial : How Numbers Get Used and Abused in the Courtroom. New York, NY, USA: Basic Books, p i.

UMEC International Corporation

SURGE PROTECTIVE DEVICES

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

SMS 4 / SMS 5 safety mat Product information

ESB and EN installation contactors Application handbook

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Transcription:

Certificate of Compliance Certificate: 2494434 (012730_C_000) Issued to: Siemens AG DF CP R&D V 3 Werner-von-Siemens-Strasse 48 Amberg, 92224 GERMANY Attention: Michael Schroeck The products listed below are eligible to bear the CSA Mark shown Issued by: J.-C. Chow J.-C. Chow PRODUCTS CLASS - C321104 - INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Magnetic CLASS - C321124 - INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers-Magnetic- CLASS - C321137 - INDUSTRIAL CONTROL EQUIPMENT - Sub-Assemblies-Components Part-A (Class 3211-04, Class 3211-24) Magnetic motor controllers, direct-on-line or reversing, Types 3RA2, open type assemblies including Certified manual motor controllers and magnetic contactors, with following ratings: Main contacts, lesser rating of Certified contactor (3RT2) and manual motor controller (3RV2) assemblies: Type 3RA2.1: lesser rating of Types 3RT201 and 3RV2.1 Type 3RA2.2: lesser rating of Types 3RT202 and 3RV2.2 Type 3RA2.3: lesser rating of Types 3RT203 and 3RV2.31; Type 3RA213.-4K rated 65 A max Type 3RA2.5: lesser rating of Types 3RT203 and 3RV2.32; Type 3RA215.-4K rated 65 A max Short-circuit ratings (RMS symmetrical amperes): Type Contactor or Reversing MMC 3RV2 Short circuit 3RA2.1 3RT201 or 3RA231, size S00 Max 16 A, 3RV2.1 (Note 1) 65 ka, 480 V 3RA2.1 3RT201 or 3RA231, size S00 Max 12.5 A, 3RV2.1 (Notes 1, 2, 3) 30 ka, 600 V 3RA2.2 3RT2024 or 3RA2324, size S0 Max 12.5 A, 3RV2.2 (Note 1) 65 ka, 480 V 3RA2.2 3RT2025 or 3RA2325, size S0 Max 16 A, 3RV2.2 (Notes 1, 4) 65 ka, 480 V DQD 507 Rev. 2012-05-22 Page 1

3RA2.2 3RT2026 or 3RA2326, size S0 Max 25 A, 3RV2.2 (Notes 1, 4) 65 ka, 480 V 3RA2.2 3RT2027 or 3RA2327, size S0 Max 32 A, 3RV2.2 (Notes 1, 4) 50 ka, 480 V 3RA2.2 3RT202 or 3RA232, size S0 Max 12.5 A, 3RV2.2 (Notes 1, 2, 3) 30 ka, 600 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2.31 (Note 5) 65 ka, 240 V 3RA2.3 3RT203, size S2 Max 52 A, 3RV2.31 (Note 5) 65 ka, 480 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2.31 (Notes 5, 7) 65 ka, 480 V 3RA2.3 3RT203, size S2 Max 65 A, 3RV2.31 (Note 5) 30 ka, 480 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2.31 (Note 5) 20 ka, 480 V 3RA2.3 3RT203, size S2 Max 36 A, 3RV2.31 (Note 5) 25 ka, 600 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2.31 (Notes 5, 6) 25 ka, 600 V 3RA2.3 3RT203, size S2 Max 52 A, 3RV2.31 (Note 5) 22 ka, 600 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2.31 (Note 5) 10 ka, 600 V 3RA2.5 3RT203, size S2 Max 52 A, 3RV2.32 (Note 5) 100 ka, 480 V 3RA2.5 3RT203, size S2 Max 73 A, 3RV2.32 (Notes 5, 7) 100 ka, 480 V 3RA2.5 3RT203, size S2 Max 65 A, 3RV2.32 (Note 5) 42 ka, 480 V 3RA2.5 3RT203, size S2 Max 73 A, 3RV2.32 (Note 5) 30 ka, 480 V 3RA2.5 3RT203, size S2 Max 36 A, 3RV2.32 (Note 5) 25 ka, 600 V 3RA2.5 3RT203, size S2 Max 73 A, 3RV2.32 (Notes 5, 6) 25 ka, 600 V 3RA2.5 3RT203, size S2 Max 65 A, 3RV2.32 (Notes 5, 8) 25 ka, 600 V 3RA2.5 3RT203, size S2 Max 52 A, 3RV2.32 (Note 5) 22 ka, 600 V 3RA2.5 3RT203, size S2 Max 73 A, 3RV2.32 (Note 5) 10 ka, 600 V Coil Ratings: 24 through 600 Vac; or 12 through 250 Vdc Notes: 1) For Types 3RA211 and 3RA221 (size S00), 3RA212 and 3RA222 (size S0), these open type assemblies are rated for use in an ambient temperature of 40 C max, except for assemblies provided with 32 A MMC 3RV2.2 are rated for use in a surrounding air temperature of 40 C max. 2) For Types 3RA2.1 and 3RA2.2 (size S00 or S0) at 30kA, 600V short-circuit rating, these assemblies with MMC 3RV2 are to be installed with Branch Circuit Protective Device Max Fuse 50 A Class J. 3) For Types 3RA2.1 and 3RA2.2 (size S00 or S0) at 30kA, 600V short-circuit rating, these screw-mounting assemblies are to be installed with an isolation between the assembly and enclosure, according to test conducted with mounting adapter Type 3RA2922-1A; the isolation may be achieved by mounting adapter, Type 8US1. For device assembly mounted on Din rail, no isolation is necessary. 4) For Type 3RA2.2 (size S0) at specified 480V short-circuit rating, these screw-mounting assemblies are to be installed with an isolation between the assembly and enclosure, according to test conducted with mounting adapter Type 3RA2922-1A; the isolation may be achieved by mounting adapter, Type 8US1. For device assembly mounted on Din rail with minimum 15 mm spacing to enclosure, no isolation is necessary. 5) For Types 3RA213 and 3RA215 (size S2), these open type assemblies are rated for use in a surrounding air temperature of 40 C max. 6) For 3RA2.3 and 3RA2.5 at 25kA, 600V short-circuit rating, these assemblies with MMC 3RV2.3 rated up to 73 Amax are to be installed with Branch Circuit Protective Device Max Fuse 225 A Class J. 7) For Types 3RA2.3 (size S2) at 65kA, 480V and 3RA2.5 (size S2) at 100kA, 480V short-circuit rating, these assemblies with MMC 3RV2.31 and 3RV2.32 (respectively) rated up to 73 Amax are to be installed with Branch Circuit Protective Device Max Fuse 300 A Class J. DQD 507 Rev. 2012-05-22 Page 2

8) For Types 3RA2.3 at 20kA, 600V and 3RA2.5 at 25kA, 600V short-circuit rating, these assemblies with MMC 3RV2.31 and 3RV2.32 (respectively) rated up to 65 Amax are to be installed with Branch Circuit Protective Device Max Circuit Breaker 200 A Type 3VL31 (frame FG by Siemens). 9) These devices may be provided with accessories of Type 8US1 Fastbus system. Part-B (Class 3211-04, Class 3211-24) Type F combination motor controllers, direct-on-line or reversing, Types 3RA2, open type assemblies including Certified Type E self-protected combination motor controllers and magnetic contactors, with following ratings: Main Contacts, lesser rating of Certified contactor (3RT2) and Type E self-protected combination motor controller (3RV2) assemblies: Type 3RA2.1: lesser rating of Types 3RT201 and 3RV2.1 Type 3RA2.2: lesser rating of Types 3RT202 and 3RV2.2 Type 3RA2.3: lesser rating of Types 3RT203 and 3RV2.31 Type 3RA2.5: lesser rating of Types 3RT203 and 3RV2.32 Short-circuit ratings (RMS symmetrical amperes): Type Contactor or Reversing Type E CMC 3RV2 Short circuit 3RA2.1 3RT201 or 3RA231, size S00 Max 16 A, 3RV2.1 (Note 1) 65 ka, 480Y/277 V, 240 V 3RA2.1 3RT201 or 3RA231, size S00 Max 10 A, 3RV2.1 (Notes 1, 2) 30 ka, 600Y/347 V 3RA2.1 3RT201 or 3RA231, size S00 Max 12.5 A, 3RV2.1 (Notes 1, 3, 5) 30 ka, 600Y/347 V 3RA2.2 3RT2024 or 3RA2324, size S0 Max 12.5 A, 3RV2.2 (Note 1) 65 ka, 480Y/277 V, 240 V 3RA2.2 3RT2025 or 3RA2325, size S0 Max 16 A, 3RV2.2 (Notes 1, 4) 65 ka, 480Y/277 V, 240 V 3RA2.2 3RT2026 or 3RA2326, size S0 Max 25 A, 3RV2.2 (Notes 1, 4) 65 ka, 480Y/277 V, 240 V 3RA2.2 3RT2027 or 3RA2327, size S0 Max 32 A, 3RV2.2 (Notes 1, 4) 50 ka, 480Y/277 V, 240 V 3RA2.2 3RT202 or 3RA232, size S0 Max 10 A, 3RV2.2 (Notes 1, 2) 30 ka, 600Y/347 V 3RA2.2 3RT202 or 3RA232, size S0 Max 12.5 A, 3RV2.2 (Notes 1, 3, 5) 30 ka, 600Y/347 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2031 (Note 6) 65 ka, 240 V 3RA2.3 3RT203, size S2 Max 52 A, 3RV2031 (Note 6) 65 ka, 480Y/277 V 3RA2.3 3RT203, size S2 Max 73 A, 3RV2031 (Note 6) 20 ka, 480Y/277 V 3RA2.3 3RT203, size S2 Max 36 A, 3RV2031 (Note 6) 25 ka, 600Y/347 V 3RA2.3 3RT203, size S2 Max 52 A, 3RV2031 (Note 6) 22 ka, 600Y/347 V 3RA2.5 3RT203, size S2 Max 73 A, 3RV2032 (Note 6) 100 ka, 240 V 3RA2.5 3RT203, size S2 Max 52 A, 3RV2032 (Note 6) 100 ka, 480Y/277 V 3RA2.5 3RT203, size S2 Max 73 A, 3RV2032 (Note 6) 30 ka, 480Y/277 V 3RA2.5 3RT203, size S2 Max 36 A, 3RV2032 (Note 6) 25 ka, 600Y/347 V 3RA2.5 3RT203, size S2 Max 52 A, 3RV2032 (Note 6) 22 ka, 600Y/347 V Coil Ratings: 24 through 600 Vac; or 12 through 250 Vdc Notes: 1) For Types 3RA211 and 3RA221 (size S00), 3RA212 and 3RA222 (size S0), these open type assemblies are rated for use in an ambient temperature of 40 C max, except for assemblies provided with 32 A CMC 3RV2.2 is rated for use in a surrounding air temperature of 40 C max. 2) For Types 3RA2.1 and 3RA2.2 (size S00 or S0) at 30kA, 600V short-circuit rating, these assemblies installed on Fastbus system are to be mounted with terminal adapter Type 3RV2928-1K for CMC 3RV2. DQD 507 Rev. 2012-05-22 Page 3

3) For Types 3RA2.1 and 3RA2.2 (size S00 or S0) at 30kA, 600V short-circuit rating, thesescrew-mounting assemblies are to be installed with an isolation provided between the assembly and enclosure, according to test conducted with mounting adapter Type 3RA2922-1A; the isolation may be achieved by mounting adapter, Type 8US1. For device assembly mounted on Din rail with minimum 15 mm spacing to enclosure, no isolation is necessary. 4) For Type 3RA2.2 (size S0) at specified 480V short-circuit rating, these screw-mounting assemblies are to be installed with an isolation between the assembly and enclosure, according to test conducted with mounting adapter Type 3RA2922-1A; the isolation may be achieved by mounting adapter, Type 8US1. For device assembly mounted on Din rail, no isolation is necessary. 5) For Types 3RA2.1 and 3RA2.2 (size S00 or S0) at 30kA, 600V short-circuit rating, these assemblies installed without Fastbus system are to be mounted with terminal adapter Type 3RV2928-1K for CMC 3RV2, or with terminal adapter kit Type 3RV2928-1H for CMC 3RV2. 6) For Types 3RA213 and 3RA215 (size S2), these open type assemblies are rated for use in a surrounding air temperature of 40 C max. 7) These devices may be provided with accessories of Type 8US1 Fastbus system. Part-C (Class 3211-37) Accessories: Link modules to connect manual/combination motor controller 3RV20 to contactor 3RT2: Types 3RA1921-1D, 3RA2911-2A, 3RA2911-2F, 3RA2921-1A, 3RA2921-2A, 3RA2921-2F; Type 3RA2931-1A rated 65 A max Link module to connect manual/combination motor controller 3RV20 to contactor 3RT2; or to solid-state motor controllers 3RW301, 3RW302, 3RW402, 3RF24, 3RF34: Type 3RA2921-1B Mounting adapter for standard Din rail: Type 3RA2922-1A, 3RA2932-1A, may be followed by additional numbers and/or letters Spacer module for AC-contactors with spring terminals: Type 3RA2911-1C, may be followed by additional numbers and/or letters General Notes: 1. The type designation may be completed with suffixes indicating shape of contacts, terminal design, mounting, etc. 2. Open-type assemblies are Certified only for use in complete assemblies where the suitability of the combination is subject to further investigation. 3. The auxiliary contacts are available as contact blocks Type 3RH29 (side or top mounted to contactor 3RT2, integrated auxiliary contacts (contactor 3RT2), and/or contact blocks Type 3RV29. Nomenclature Breakdown 3RA2 1 1 0-0B A 15 0 - I II III IV V VI VII VIII IX I II Controller designation 3RA2 Basic device Controller type 1 Direct-on-line contactor 2 Reversing contactor DQD 507 Rev. 2012-05-22 Page 4

III IV V Size of controller, contactor Type and 3RV20 1 Size S00, contactor Type 3RT2.1 and 3RV2.1 2 Size S0, contactor Type 3RT2.2 and 3RV2.1 3 Size S2, contactor Type 3RT2.3 and 3RV2.31 (standard short circuit breaking capacity) 5 Size S2, contactor Type 3RT2.3 and 3RV2.32 (higher short circuit breaking capacity) Auxiliary contact arrangements of the 3RV20 0 None provided 1 1 normally open and 1 normally closed, side mounted 2 2 normally open, side mounted 3 2 normally closed, side mounted 4 1 changeover contact, top mounted 5 1 normally open and 1 normally closed, top mounted 6 1 normally open and 1 normally closed with spring terminals, top mounted (only for versions A, B and D according VI of the Nomenclature Breakdown) Current setting range of 3RV20 Suffix Setting range Size 0A 0.11-0.16 A S00, S0 0B 0.14-0.2 A S00, S0 0C 0.18-0.25 A S00, S0 0D 0.22-0.32 A S00, S0 0E 0.28-0.4 A S00, S0 0F 0.35-0.5 A S00, S0 0G 0.45-0.63 A S00, S0 0H 0.55-0.8 A S00, S0 0J 0.7-1.0 A S00, S0 0K 0.9-1.25 A S00, S0 1A 1.1-1.6 A S00, S0 1B 1.4-2 A S00, S0 1C 1.8-2.5 A S00, S0 1D 2.2-3.2 A S00, S0 1E 2.8-4 A S00, S0 1F 3.5-5 A S00, S0 1G 4.5-6.3 A S00, S0 1H 5.5-8 A S00, S0 1J 7-10 A S00, S0 1K 9-12.5 A S00, S0 4S 9.5-14 A S2 4A 10-16 A S00, S0 4T 12-17 A S2 4B 13-20 A S0, S2 4C 16-22 A S0 4D 18-25 A S0, S2 4N 23-28 A S0 4E 27-32 A S0 4E 22-32 A S2 DQD 507 Rev. 2012-05-22 Page 5

VI VII VIII IX X 4P 28-36 A S2 4U 32-40 A S2 4F 28-40 A S2 4V 35-45 A S2 4G 36-45 A S2 4H 40-50 A S2 4W 42-52 A S2 4X 49-59 A S2 4J 54-65 A S2 4K 62-73 A S2 Mounting and type of terminals A Without Mounting rail adapter, screw terminals B With Mounting rail adapter (only for reversing size S0), screw terminals D With Fastbus adapter, screw terminals (only for size S00 or S0) E Without Mounting rail adapter, spring terminals F With Mounting rail adapter (only for reversing size S0), spring terminals (not for Part-B ) H With Fastbus adapter (size S00 and S0), spring terminals (not for Part-B ) S With Fastbus adapter (size S00), spring terminals (not for Part-B ) Type of contactor or reversing contactor 15 Type 3RT2015 contactor or 3RA2315 reversing contactor 16 Type 3RT2016 contactor or 3RA2316 reversing contactor 17 Type 3RT2017 contactor or 3RA2317 reversing contactor 18 Type 3RT2018 contactor or 3RA2318 reversing contactor 24 Type 3RT2024 contactor or 3RA2324 reversing contactor 25 Type 3RT2025 contactor or 3RA2325 reversing contactor 26 Type 3RT2026 contactor or 3RA2326 reversing contactor 27 Type 3RT2027 contactor or 3RA2327 reversing contactor 34 Type 3RT2034 contactor 35 Type 3RT2035 contactor 36 Type 3RT2036 contactor 37 Type 3RT2037 contactor 38 Type 3RT2038 contactor Auxiliary contact arrangement 0 With 1 NO + 1 NC for size S0 or S2 1 With 1 NO for size S00 only 2 With 1 NC for size S00 only Indicates coil voltage and optional external overvoltage protection Manufacturers Identification APPLICABLE REQUIREMENTS CSA-C22.2 No. 14-13 - Industrial Control Equipment CAN/CSA-C22.2 No 60947-1-13 - Low-Voltage Switchgear and Controlgear - Part 1: General rules DQD 507 Rev. 2012-05-22 Page 6

CAN/CSA-C22.2 No 60947-4-1-14 - Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters DQD 507 Rev. 2012-05-22 Page 7