Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D



Similar documents
Quick Connect. quick - simple - efficient.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power Meter Series 700

Applications. diris_826_a_1_gb_cat

Energy Management Energy Meter Type EM23 DIN

A project to optimise quality and energy efficiency must include metering

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Installation manual. Generator Paralleling Controller GPC multi-line C

Application/Connection Examples

Energy Management Power Analyzer Type WM14-96 Basic Version

E-STOP relays, safety gate monitors

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

M2M The measure of efficiency

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Rack mounted telephone- and leased line modem for industrial applications

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Multifunction devices

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

One Meter Works for Both Energy Saving and Power Quality Surveillance

Telephone- and leased line modem for industrial applications TD-36

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

Voltage Regulator SPAU 341 C. Product Guide

38 Series - Relay interface modules A

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Uninterruptible Power Supply

Metering Devices IQ Analyzer 6400/6600 Series

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PNOZsigma - Base units

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

MasterINTERFACE 39 Series - Relay interface modules

Power Meter Series 800

MasterINTERFACE 39 Series - Relay interface modules

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

38 Series - Relay interface modules A

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

EM-PQ 1500 Power Quality Monitor. Operating Manual

MAJORSINE Power Inverter

How To Use A Ds340 (Dsp)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Technical Data. back-up time in minutes 100% load % load

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Bimetallic Overload Relay Specifications

FIREDEX Conventional Fire Panels

Energy Management Energy Analyzer Type EM24 DIN

Electrical Measuring Instruments

TX2123 RS485 TO ETHERNET ADAPTOR

Polyphase kwh Electricity Meter

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

NC-12 Modbus Application

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

PSR The compact range Description

Measuring and monitoring units VAMP 96 VAMP 260 WIMO 6CP10

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Safety technique. Emergency stop module BO 5988 safemaster

Electrical measurement and control M.5. CVM Power analyzers

48 SERIES Relay interface modules 10 A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

B21 User Manual Document ID: 2CMC485004M0201 Revision: A

3-phase, bidirectional energy meter

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Indoor / Outdoor Antenna

Panorama Electricity meters For reliable values of energy consumption

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Remote Monitoring and REC 501 Control Unit Product Guide

Preset Counter signo 721

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

E-STOP relays, safety gate monitors

80 Series - Modular timers 16 A. Features

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Three-phase monitoring relay CM-PFE

1. INTRODUCTION FEATURES 2. PROGRAMMING

Energy Division

Paralleling and Protection Unit Type PPU multi-line E

E-STOP relays, safety gate monitors

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Maximum Demand Control

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Contact expansion modules

Eaton s E-Series protective relay family

Electronic overload relay EF65, EF96 and EF146

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Transcription:

7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values class 1.0 Display 4 display rows 58 x 66mm White backlight Intelligent Suitable for all 3-phase network topologies Replaces transducers DEIF A/S Installation Compact dimensions Simple wiring Models 7000: Basic 7000C: Basic + RS485 Modbus communication 7020: Basic + 2 digital outputs DEIF A/S

Application The multi-instrument is a microprocessor-based measuring unit providing measurement of most electrical quantities on a 3-phase electric energy distribution network. The measurements are shown on the built-in display. The product family includes three versions: 7000 (basic) 7000C (basic + RS485 Modbus communication) 7020 (basic + 2 digital outputs) True RMS values on all 3-phase network topologies are measured with/without neutral and with both balanced and unbalanced load. A large number of standard analogue instruments can be replaced by the in all electrical measuring applications. The contains all necessary measuring circuits and presents all values on a display with white backlight. The display has 4 digits resolution for all measurements. The backlight on-time is selectable. Operating the is very easy. It is a flexible and logical measuring unit that enables the user to easily adapt the instrument to the individual application. Counter reset and change of settings can be password protected. Measured and calculated values Voltage True RMS each phase and line-to-line voltage. Current Each phase, average and neutral. Active power (P) Active, total and demand power. Reactive power (Q) Reactive, total and demand reactive power. Apparent power (S) Apparent and total apparent power. Power factor Power factor and total power factor. Actual frequency of L1. Load nature L/C/R. Digital output (DO) For alarm output or energy pulse output. Min./max. Min./max. of voltage max. of current and demand. Energy pulse output Two ports of pulse output (assign to any energy and reactive energy). THD (up to 15th harmonics) Voltage THD of each phase and total, current THD of each phase and total. Demand Demand of each phase current, power and reactive power. Energy Import and export of energy, inductive and capacitive of reactive energy. Alarm Alarm can be related to any metering parameters. Running hour Meters the duration of the operation. Unbalance factor Voltage and current. Connection The can be used in almost all 3-phase network topologies with/without neutral and with both balanced and unbalanced load. The voltage and current input wiring modes are set separately in the parameter setting process. The voltage wiring mode can be: 3LN 2LN 1LN 2LL 3LL 3-phase 4-line Y 3-phase 4-line Y with 2 VT 1-phase 2-line 3-phase 3-line open delta 3-phase 3-line direct connection The current input wiring mode can be: 3CT 2CT 1CT Unbalance system Unbalance system without N Balance system Any voltage mode can be grouped with any of the current modes. The is supplied configured in 3-phase 4-wire unbalanced mode, i.e. voltage wiring mode 3LN and current input mode 3CT (3W4). Communication (optional) Suitable for SCADA systems RS485 serial output Modbus RTU protocol DEIF A/S Page 2 of 5

Digital output 7020 7020 has two digital outputs that can be used either as pulse outputs for active/reactive energy or as over/under limit alarm signals. The digital outputs are suitable for driving tariff devices or AC/DC relays. Digital output circuit (pulse) DEIF A/S Page 3 of 5

Technical specifications Voltage inputs Nominal voltage U N Overload capacity VT primary VT secondary Fuse Current inputs Nominal current I N Overload capacity CT primary Nominal frequency f N Measuring point Accuracy Voltage Current Power Power factor Energy Harmonic L-N 400V AC L-L 690V AC 0 to 1.2 x U N 2 x U N continuously 2500V for 1s 50V 1000kV 50V 400V 1A/230V 1 or 5A AC 0 to 1.2 x I N 10A continuously 100A for 1s 5A 50kA 50/60Hz 45Hz to 65Hz V1 phase voltage 1.0% of reading 1.0% of range 1.0% of range 2.0% of range Auxiliary power supply Universal AC/DC power supply Supply voltage AC: 100 415V AC +/-10% 50/60Hz/ Consumption 2VA Fuse 1A/250V AC Power consumption 3VA@230V AC Digital output (optional) Output form Digital output NE (normally energised) NC (normally closed) circuit form is Photo-MOS Communication (optional) Signal levels Connection type Devices per link Cable type Maximum cable length Transmission mode Message format Data rate RS485 Multi-drop Max. 32 units Belden 3105A or equivalent (twisted pair) up to 1000m Asynchronous Modbus RTU 1 200 to 38 400 bits/s Environmental conditions Working temperature, display -10 55 C Storage temperature -40 85 C Humidity, relative 0-95% non-condensing Temperature drifts <100ppm/ C Standard EN 60068-2/-1,-2 Connections Measuring inputs Wire max. Screw torque Other Wire max. Screw torque Mounting Panel mounted Panel cutout Firm terminal block 5mm²/AWG10 0.5Nm/5.5 lb-inch Pluggable block 1.5mm²/AWG16 0.25Nm/2.5 lb-inch Max. 6mm thick 92 x 92mm +0.8mm (3.62 x 3.62 ) or 4 round Protection Front IP52 (EN 60529) Rear IP30 (EN 60529) Weight 350g (0.8 lbs.) Material Environmental IEC 60068-2 EMC EN 61000-6-1/2/3/4 Optical isolation Voltage max. Current max. Pulse rate Pulse duration 4kV AC rms 250V AC/300V DC 50mA 0.1 600kWh/pulse 0.1 600kVArh/pulse 20ms 1s Safety Test voltage EN 61010-1/UL 61010-1 Cat. III, pollution degree 2 2.2kV according to EN 61010-1 DEIF A/S Page 4 of 5

Unit dimensions in mm (inches) Panel cutout H x W = 92.00 x 92.00 + 0.5 (3.62 x 3.62) Order specifications 7000 7000C 7020 No digital output No digital output RS485 Modbus communication 2 digital outputs DEIF no. 1211020007 EAN no. 5703727106882 DEIF no. 1211020011 EAN no. 5703727108564 DEIF no. 1211020008 EAN no. 5703727106899 Due to our continuous development we reserve the right to supply equipment which may vary from the described. DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Tel.: 9614 9614, Fax: 9614 9615 E-mail: deif@deif.com, URL: www.deif.com