3. Three phase winding technology



Similar documents
COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Single Layer Winding Of Three Phase Induction Motor

Principles and Working of DC and AC machines

DIRECT CURRENT GENERATORS

Basics of Electricity

Prof. Krishna Vasudevan, Prof. G. Sridhara Rao, Prof. P. Sasidhara Rao. x x. x x. Figure 10: Cross sectional view

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

Motor Fundamentals. DC Motor

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

8 Speed control of Induction Machines

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Principles of Adjustable Frequency Drives

Development Of High Efficiency Brushless DC Motor With New Manufacturing Method Of Stator For Compressors

Power Plant Electrical Distribution Systems

Unit 33 Three-Phase Motors

Raising the waters. Lift irrigation is getting a boost from ABB s synchronous motors

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts

Understanding the Alternator

AC Induction Motor Slip What It Is And How To Minimize It

Large Generators and High Power Drives

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

8022-0E Motor Winding Kit

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Chapter 22: Electric motors and electromagnetic induction

Introduction. Upon completion of Basics of AC Motors you should be able to:

Basic Concepts of A Machine

Generators TEM. for small hydroelectric power stations. Electric Machines

Data Sheet. AC Industrial Electric Motors

Chen. Vibration Motor. Application note

Lab 37: Magnetic Field ; Magnets - Drawing magnetic fields - Magnetic poles - Forces between magnets

Enhancing the Design of Electric Machines through the Interaction of Software Tools. Markus Anders Electric machine sector manager CD-adpaco

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

The half cell of the storage ring SESAME looks like: Magnetic length =

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Induction Motor Theory

Preview of Period 16: Motors and Generators

THIS paper reports some results of a research, which aims to investigate the

Turbo generators Best quality for thermal power plants

Traditional Design of Cage Rotor Induction Motors. Ronald G. Harley and Yao Duan Georgia Institute of Technology November, 2009

NATIONAL CERTIFICATE (VOCATIONAL)

CONTINUOUS AUTOMATED FLUX MONITORING FOR TURBINE GENERATOR ROTOR CONDITION ASSESSMENT

13 ELECTRIC MOTORS Basic Relations

1. The diagram below represents magnetic lines of force within a region of space.

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

How the efficiency of induction motor is measured?

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Vehicle Design Summit Electric Hub Motor (V2) Eric Conner Harvey Tang Matthew Peddie

Three-phase AC circuits

HIGH SPEED PERMANENT MAGNET SYNCHRONOUS MOTOR / GENERATOR DESIGN FOR FLYWHEEL APPLICATIONS

Introduction. Three-phase induction motors are the most common and frequently encountered machines in industry

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

S Y N C H R O N O U S G E N E R A T O R S

L.I. Chubraeva. Corr. Member of RAS

IV. Three-Phase Induction Machines. Induction Machines

Powerformer chosen for Swedish combined heat and power plant

BCI184E - Technical Data Sheet

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Linear DC Motors Magnetic Flux Permanent Bar Magnets

Objectives. Capacitors 262 CHAPTER 5 ENERGY

Lab 14: 3-phase alternator.

Eðlisfræði 2, vor 2007

1150 hp motor design, electromagnetic and thermal analysis

!! #! # %! & () +,+. + / ! 34 & ) ( 3,( , ( 338

How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

SYNCHRONOUS MACHINES

WIND TURBINE TECHNOLOGY

TARIFF CODE and updates standard

Welcome to Linear Controls Quarterly Training

COIL PAC. Subec AB, Sprängarvägen 16, Saltsjö-Boo, Sweden, Tel.: , Fax: , info@subec.se

PM734F - Technical Data Sheet Winding 28

Chapter 4.5: Electric Motors, Variable Speed Drives

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

INSTRUMENTATION AND CONTROL TUTORIAL 2 ELECTRIC ACTUATORS

PMDD WIND TURBINE 1.5MW

Lab 8: DC generators: shunt, series, and compounded.

Motors and Generators

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

Service Life of Stator Winding Insulation as an Important Quality Feature of Large Hydro Generators

Outline. Turbine Generators. Generator History 3/25/2014

Modeling and Simulation of a Large Chipper Drive

PI734D - Technical Data Sheet

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

PI734B - Technical Data Sheet

ELECTRODYNAMICS 05 AUGUST 2014

Torque motors. direct drive technology

Synchronous generators are built in large units, their rating ranging from tens to hundreds of megawatts.

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Synchronous motor. Type. Non-excited motors

The electrical energy produced at the gen


UCI274C - Technical Data Sheet

Power Transformers 10 to 100 MVA

Transcription:

3. Three phase winding technology VATech Hydro, Austria Prof. A. Binder 3/1

Single layer winding Per slot only one coil side is placed. Coils manufactured as: a) Coils with identical coil span: W = τ p b) Concentric coils Example: Three-phase, 12-pole machine with q = 3 coils per pole and phase: Total slot number: Q = m. 2p. q = 3. 12. 3 = 108 North- and south pole are generated by ONE coil group per phase. Problem with single layer windings: Crossing of coils in winding overhang part, as all coils are lying in the same plane. Thus some coils must be bent upward in winding overhang region ( 2 nd plane ). Prof. A. Binder 3/2

Example: Single layer winding with short and long coils Unrolled winding system gives winding scheme : her four-pole machine: 2p = 4, m = 3, q =2, Q = 24 Winding manufactured with concentric coils. Long coils : Winding overhang part of coils is longer; so these coils may be bent upwards! Each phase has one pole pair with short and one pole pair with long coils! So resistance per phase is equal, but minimum of 4 poles required! Prof. A. Binder 3/3

Stator three phase single-layer winding of induction machine Round wire coils ELIN EBG Motors, Austria Prof. A. Binder 3/4

Two-layer winding Coils with equal span Two-layer winding: Per slot TWO coil sides are placed one above the other. North- and south pole are generated by two coil groups. Direction of current flow in N- and S-pole coils opposite! Changing of current flow direction by reversal connector. Bigger machine ratings typically above 500 kw: Profiled coil conductors (rectangular cross section), round wire with smaller machines! Example: For 4-pole machine we need four coil groups per phase! Prof. A. Binder 3/5

Winding overhang of two-layer winding a) Two form wound coils before being put into the stator slots: Due to S-shape in winding overhang part of coils there are NO crossing points of the coils. b) Form wound coil with profiled conductor, placed in stator slot, with left coil side in lower and right coil side in upper layer. Manufacturing much more expensive than with round wire single-layer winding, therefore used usually only in bigger machines: e.g.high voltage machines up to 30 kv ( High voltage : U > 1000 V (rms)!). a) b) Coil side Winding overhang slot Prof. A. Binder 3/6

High voltage form wound stator coil with several turns N c for two-layer winding Winding overhang coil side, inserted in slot coil terminals VATech Hydro, Austria Prof. A. Binder 3/7

Pitching (chording) of coils W < τ p With Two-layer windings: pitching of coils is possible! Pitching = Shortening of coil span W, counted in number S of slot pitches W m q S = τ p = τ m q p YQ S : integer number m q Benefit of pitching: Shape of field curve fits better to ideal sinusoidal shape. Example: Four-pole machine: Data: m = 3, Q = 24, q = 2: Pitching is pöossible for S < mq = 3. 2 = 6: S = 1, 2, 3, 4, 5. e. g.: S = 1, hence pitching is W/τ p = 5/6. Prof. A. Binder 3/8

Example: Pitched Two-layer winding Four pole machine, m = 3, Q = 24, q = 2: Pitching W/τ p = 5/6. Prof. A. Binder 3/9

Inserting form-wound two-layer winding in induction generator stator Winding overhang Stator iron stack coil ends Winergy Germany Prof. A. Binder 3/10

Inserting form-wound two-layer winding in stator slots Winding overhang Stator iron stack slots ABB, Switzerland Prof. A. Binder 3/11

Stator three phase two-layer winding of induction generator Winergy Germany Prof. A. Binder 3/12

Rotor three phase two-layer winding of slip ring induction generator Winergy Germany Prof. A. Binder 3/13

Inserting of impregnated form wound coils in the stator slots of a synchronous hydro generator with high pole count Ventilation duct Tooth Slot Massive iron clamping finger Pressing plate 1 st layer 2 nd layer winding overhang VATech Hydro, Austria Prof. A. Binder 3/14

Series and parallel connection of coil groups Series and parallel connection of coil groups to get one winding phase Example : Eight-pole machine: Two-layer winding: 8 coil groups, which may be connected as follows: a = 1: Series connection of all 8 coil groups a = 2: 4 coil groups in series, then paralleling the two series sections a = 4: 2 coil groups in series,then paralleling the four series sections a = 8: All 8 coil groups are connected in parallel Single-layer winding: 4 coil groups, which may be connected as follows: a = 1: Series connection of all 4 coil groups a = 2: 2 coil groups in series, then paralleling the two series sections a = 4: All 4 coil groups are connected in parallel Resulting number of turns per phase N: pqnc 2 pqnc N = Single-layer winding N = Two-layer winding a a Example: 2p = 4, q = 2, eleven turns per coil (N c = 11), series connection of all coil groups: a = 1: number of turns per phase: N = 4. 2. 11/1 = 88 Prof. A. Binder 3/15

Variants of cooling of winding and iron stack Heat flow density (W/cm 2 ) Indirect aircooled stator winding Stator iron stack packets Directly air-cooled rotor pole winding Air/hydrogen water Prof. A. Binder 3/16 Directly cooled hollow conductors For comparison: Heat transfer of flat -iron

Rated voltage U n of stator winding increases with increasing apparent power S n to limit rated current I n Prof. A. Binder 3/17

Welded stator housing of synchronous hydro generator VATech Hydro, Austria Prof. A. Binder 3/18

Stacking of stator iron sheets of synchronous hydro generator VATech Hydro, Austria Prof. A. Binder 3/19

Pressing of laminated stator iron core with hydraulic cylinders VATech Hydro, Austria Prof. A. Binder 3/20

Insulation of high voltage stator winding (one turn = stator bar) with insulation robot Big generators: Only one turn per coil. Coil is split into 2 halves = 2 bars. Here visible: Insulating one bar for a 2-pole turbine generator with glass-fibre band with mica layer for high voltage insulation. VATech Hydro, Austria Prof. A. Binder 3/21

Insulation of high voltage stator winding (one turn = stator bar) with insulation robot VATech Hydro, Austria Prof. A. Binder 3/22

Resin impregnated coils are heated in the oven to dry and harden the insulation VATech Hydro, Austria Prof. A. Binder 3/23

High voltage stator winding of synchronous hydro generator - Pressing of winding bars in the slots VATech Hydro, Austria Prof. A. Binder 3/24