2.4 Hardcopy submittals shall be provided at adequate size so that all notes are readable.



Similar documents
All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.

Schematic Design: Quality Management Phase Checklist Project Phase Checklist Series

BUILDING SAFETY UNIT

Design Development Quality Management Phase Checklist Project Phase Checklist Series

Lincoln Public Schools. 15 Attachments (separately bound) Schematic Design Schematic Design Project Manual

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Design and Construction Design Phase Deliverables

Building Permit Application

9770 CULVER BOULEVARD CULVER CITY, CA Incidental improvements: improvements that do not qualify as minor or

Electrical. This section applies to the design and installation of building power distribution systems.

Exhibit C: Scope of Work and Schedule of Deliverables

2012 BIM Guidelines and Standards (Rev. 00) University at Albany

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

Current as of 11/10/08 1 of 1

PARKVILLE HIGH SCHOOL LIMITED RENOVATION

City of La Vernia 102 E. Chihuahua Street, La Vernia, Texas Phone: (830) Fax: (830)

Code Requirements for Existing Buildings

PLAN SUBMITTAL INFORMATION

REQUEST FOR PROPOSAL FOR PROFESSIONAL SERVICES (PS-0748-A) Appendix 1 Project Information. PS-0748-A Page 1 5/4/2016 Appendix 1

Schematic Design Presentation S. Dallas Dance, Superintendent October 22, 2013 OVERLEA HIGH SCHOOL

CITY OF YORBA LINDA P.O. BOX CALIFORNIA

Revised Work Scope Dated April 23 rd, 2015

Element Z General Design Requirements Standards and Other Requirements

EXHIBIT "A" RESPONSIBILITIES AND SERVICES OF ARCHITECT TABLE OF CONTENTS

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW

Construction Technologies Career Field Pathways and Course Structure

Element D Services Plumbing

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

Preliminary Plan Application and Checklist

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

Schedule B to By-law

city of edmonds development information

Lot Number. City. Architect Name SUBCONTRACTORS - COMPLETE AND ATTACH LIST ON PAGE 4

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

SUBJECT CAN: Temporary Systems, Utilities and Equipment. Effective: 4/09/2013. CODE SECTION 2010 California Building Code (CBC)

Commercial Building Permit Application & Submittal Guidelines

Planned, Limited Notice and Emergency Outage Guidelines

Overview of Land Construction Courses at Kansas State University

City of Oviedo Commercial Shell Building Permit Application Guidelines

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

EXHIBIT "A" RESPONSIBILITIES AND SERVICES OF ARCHITECT TABLE OF CONTENTS

Accela Automation User Manual for Gwinnett County Automated Inspection Request System (IVR)

NORTHERN ARIZONA UNIVERSITY EXHIBIT A SCOPE OF SERVICES FOR DESIGN PROFESSIONAL TO STANDARD FROM AGREEMENT BETWEEN OWNER AND DESIGN PROFESSIONAL

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Post Occupancy Evaluation (POE) Technical Instructions

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

NECESSITY OF SCHOOL CONSTRUCTION STAGE III DESIGN REVIEWS

Civil Engineering and Architecture (CEA) Detailed Outline

VIRGINIASCAN OFFICE BUILDING DATA SHEET

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

PLUMBING PERMIT REQUIREMENTS AND CHECKLIST

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

APEC CAPABILITIES PROJECT MANAGEMENT / SUPPORT

BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General

SAMPLE. CONTRACT FOR PROFESSIONAL SERVICES: Lump Sum by Phase. Federal Identification (I.D.) Number

APPLICATION FOR NEW CONSTRUCTION

Data Center Due Diligence List

MEASURE G-2010 EXHIBIT B FULL TEXT BALLOT PROPOSITION OF THE SAN JOSE EVERGREEN COMMUNITY COLLEGE DISTRICT BOND MEASURE ELECTION NOVEMBER 2, 2010

City of Douglas Commercial Building Permit Site Application

City of Colleyville Community Development Department. Site/Landscape Plan Application Packet

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Certification: Building Plans Examiner. Exam ID: B3

Sample DEQ Plan Submitter s Checklist for Stormwater Management Plans

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Request for Qualifications

City of Riverside Building & Safety Division Phone: (951)

2014 Limited Plan Submittal Checklist

COOK PHYSICAL SCIENCE BUILDING RENOVATIONS. Engineering & Architectural Services CONCEPT DESIGN MAY 11, BVH Project No.

INTRODUCTION COST AND FEASIBILITY OF RENOVATING OR REPLACING AN OLD SCHOOL BUILDING

Building Condition Assessment Report

Note: All terms which are defined and which are used throughout this document appear in italicized text beginning with a CAPITAL letter.

T109 Architectural Technology MTCU Code Program Learning Outcomes

Element D Services Plumbing

REQUEST FOR ARCHITECTURAL SERVICES (RFS)

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

MECHANICAL PLAN REVIEW REQUIREMENTS

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED

Contents. 1.0 Introduction Project definition Project brief Accommodation guidelines Objective 4

Presentation to Senate Select Committee on Government Facilities: Deferred Maintenance for State Supported Living Centers and State Hospitals

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

University of Northern Iowa Facilities Services

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

DRAPER ELEMENTARY SCHOOL

KBC Chapter 34 : Applying the Kentucky Building Code to Existing and Historic Buildings

ARCHITECTURAL SERVICES AGREEMENT

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Transcription:

DESIGN EQUIEMENTS POJECT DELIVEABLES CHECKLISTS GENEAL INFOMATION 1.1 The following is a checklist to be used as a guide for the required deliverables for the Schematic Design phase. 1.2 Schematic Design deliverables shall consist of drawings, narrative, reports, analysis, models and renderings, etc. that are deemed appropriate and necessary to properly convey the scope of the proposed work along with existing conditions. Appropriate level of design and documentation will allow for the expeditious review and acceptance of the Schematic Design phase, by all project stakeholders. 1.3 Schematic Design Phase Work may be based on a Feasibility Study, or it may commence if determined by CUF that a Feasibility Study is/was not required. DESIGN EQUIEMENTS 2.1 All drawings shall have the appropriate title block that complies with CUF and the Department of Building guidelines and include the Columbia University Facilities Logo. Title block shall contain name of the project, name of the building, floor, date, scale, consultants and subconsultants at minimum. 2.2 Orient all plans with north to the top of the page. 2.3 Drawings shall be 24 x36 maximum as a standard document size. 11 x 17 and 8 ½ x 11 minimum size drawings shall be used if appropriate to the scale and scope of the work at the SD level. 2.4 Hardcopy submittals shall be provided at adequate size so that all notes are readable. 2.5 Scale of drawings shall be no less than 1/16 and preferable no less than 1/8 scale UON. 2.6 Drawing numbering shall be reviewed at start of the project. 2.7 Schematic Design Checklist The following checklist is a comprehensive list for the schematic design phase work. Certain requirements may be waived as is appropriate to the size and scale of project. This shall be determined by the Project Manager at the kickoff meeting. END OF SECTION 1

DESIGN EQUIEMENTS evision Approval: evision #: Joe Mannino Date Frank Martino Date 2

DESIGN EQUIEMENTS SCHEMATIC DESIGN CHECKLIST = required GENEAL Basis of Design eport (see Section 00 00 14). Preliminary equipment and furnishings lists Outline Specification following CSI format ACHITECTUAL Title Sheet a. Drawing list b. Columbia University Logo and Facilities information c. Project name, building name, and floor location with general notation of work type d. Provide with site location information for small projects not requiring full site plan, including Campus Plan. (refer to 1.2-1.5) e. Building Department notes including special inspections Projects impacting a building's size or footprint shall include a detailed site plan (1.2-1.5) Site Location Plan Showing site relative to city center, major landmarks, major parking facilities, major roads, mass transit links, etc. Existing Site Plan/Campus Plan (at least one block around site) describing: a. Site boundaries, approximate topography, existing buildings, setbacks and easements. b. Climatic conditions including path of sun. c. Location of on-site and off-site utilities. d. Natural landscape features. e. Utilities requirements (type, estimated load, proposed routing and connections. Electric (normal) Gas Electric (standby) Storm piping sanitary Electric (emergency) Chilled water Fire Protection Condensate Telecommunications Air Steam Fuel storage tanks Storm water detention Water storage tanks f. Pedestrian and vehicular circulation (include the direction of traffic on adjoining streets) 3

DESIGN EQUIEMENTS Proposed Site Plan Showing at minimum the following, and existing conditions as required per 1.3): a. Building location and massing. b. Building expansion/phasing, if applicable. c. General landscape design approach. d. Site circulation, parking, service areas and all pavements. (as available and when required) e. When filing for PELIMINAY SITE PLAN APPOVAL, conform to all additional local submission requirements. Floor Plans, demolition plans, and reflected ceiling plans, showing at minimum a. Entrances, lobbies, corridors, stairways, elevators, work areas, special spaces and service spaces (with the principal spaces labeled). b. Overall dimensions and dimensions for critical clearances. c. Proposed removals and scope of work d. eflected ceiling plans showing proposed removals, of all existing equipment and lighting, and proposed scope of work. e. Demolitions notes, General Construction Notes and Scope Notes f. Accessible path of travel diagram, including building entry, restrooms, drinking fountains and telephones. g. Egress plan h. oom numbering plan and proposed space use (follow FICM Guidelines). i. Equipment plan Elevations of major building façades, showing fenestration and major exterior materials. Building Sections (as necessary), showing floor-to-floor and other critical dimensions. Interior elevation sections showing existing construction, floor to floor, profile structural members, major utility services, fenestrations, etc. Photographs of existing conditions and context. Massing Model of the architectural design scheme on a common base, without fenestration, and/or renderings. Perspectives and other design aids to express clearly the design intent Marketing and communications materials to assist in the fundraising effort. oof plan and details(when required); minimum 1/16 scale Plans of special floors with related work SITE PLANNING AND ENGINEEING (as required) Site Layout Plan showing roads, walks, parking and other paved areas, handicapped access route from parking and from public street to main entrance. 4

DESIGN EQUIEMENTS Grading and Drainage Plan showing site grading and storm drainage inlets, including storm water detention features. Site Utilities Plan showing sizes and locations of all required utility connections. STUCTUAL (as required to show existing and proposed conditions) Preliminary Foundation Plan Preliminary Framing Plans for all floors and roof Description of potential framing systems, with recommendation supporting chosen scheme. Indicate any affect on existing structural components. In buildings with sensitive equipment incorporate vibration analysis. Description of seismic design requirements. (as required) Code Analysis (structural) including: a. List of applicable codes with code dates. b. Building classification. c. Identification of seismic zone, wind speed, etc. d. Identification of special requirements, such as high-rise. e. Identification of unusual local code requirements. MECHANICAL: HVAC Preliminary Plans a. Show mechanical room and equipment location, size and space requirements for all mechanical equipment and existing system tie-ins, including approximate sizes of fans, pumps, compressors, heat exchangers, etc. based on available information. b. Show shaft locations and approximate sizes with supply, return, fresh air, and exhaust ductwork and piping. c. Provide system single line diagram demonstrating design intent. PLUMBING Preliminary plans of toilet room / pantry / lab service locations and layouts including those closest to the area of work when work is a renovation (these may be a floor above or below area of work scope) FIE POTECTION Preliminary plans of fire protection (FP) sprinkler layout, sizes, riser, run and existing tie in locations. ELECTICAL Preliminary Plans showing 5

DESIGN EQUIEMENTS a. Location, size and space requirements for all electrical equipment. b. Main electrical feed(s) c. Panel and subpanel locations d. Lighting layout (CP) including type count and circuiting e. Fire alarm system components and connection point f. Proposed emergency and standby power loads, connection point and capacity analysis TELECOMMUNICATIONS AND DATA Existing and proposed plans of telecommunications devices, connection points and termination locations, including tele/data closets, and pathways, and wireless locations 6