1 TankJet Tank Cleaning Products Experts in Technology s Control Analysis Fabrication

2 Optimizing Tank Cleaning Operations Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you can do to maximize the performance of your tank cleaning equipment. We ve included optimization tips and guidelines in this bulletin to help you achieve optimal cleaning efficiency. Getting Started If you are cleaning your tanks manually Changing to an automated method will yield many benefits: More consistent, thorough cleaning Improved worker safety by removing contact with hazardous chemicals Faster cleaning downtime is minimized and tanks are returned to service more quickly Reduced use of water, chemicals and lower wastewater disposal costs Workers can be deployed to other tasks If you are currently using tank cleaning nozzles or a tank cleaning machine You may be able to improve cleaning efficiency by making some simple changes or using different equipment. Technology advancements have made it easier to remove stubborn residues, shorten cleaning cycle times and achieve higher levels of automation. The first step to optimizing tank cleaning is to audit your operations. How many tanks require cleaning and what is the diameter, length and height of each? Are there obstructions in your tanks such as agitators or mixers? Are there certain areas that need more cleaning than others such as skim lines? What residue needs to be removed? Is it sticky? Or is it easily rinsed away? Are cleaning agents required or is water sufficient? Is it necessary to heat the cleaning liquid? What problems are you experiencing with your current cleaning method? Equipped with the answers to these questions, you should be ready to start evaluating your options.

3 Optimizing Tank Cleaning Operations Selecting the Right Equipment The chart below shows all of our tank cleaning products and the maximum tank diameter each unit can clean. The maximum tank diameter is defined as the total distance the spray can travel to tank walls assuming the unit is positioned in the center of the tank. The closer the nozzle is to the tank wall, the greater the impact. The chart also shows recommended minimum tank diameters. It is possible to use some tank cleaners in smaller tanks than recommended, but consider the size of the unit and the liquid volumes. Maximum Tank Diameter Feet Meters TankJet 360/363 TankJet 180 TankJet AA290 TankJet AA190-HP5 TankJet 80 TankJet 65 TankJet AA190 and AA190H TankJet 75 TankJet and 27500R TankJet TankJet D26984 TankJet D40159 TankJet and 28500R TankJet TankJet D41800E TankJet 6353 and 6353-MFP TankJet AA090 TankJet 18250A TankJet TankJet D41892 TankJet D41990 TankJet 21400A TankJet VSM TankJet TankJet 3150 TankJet TankJet up to 3 up to 3 up to 3 up to 2 up to 8 up to 8 up to 8 up to 6.5 up to 6.5 up to 5 up to 5 up to 18 up to 13 up to 12 up to 10 up to 50 up to 40 up to 34 up to 30 up to 25 up to 22 up to 20 up to 20 up to 80 High Impact Cleaning Medium Impact Cleaning Low Impact Cleaning Rinsing

4 Optimizing Tank Cleaning Operations Comparing the Options up to 100 up to 80 up to 80 Your final decision will be determined by tank size and level of cleaning required. However, here are a few more things to keep in mind as you work through the selection process: High impact cleaning is required to remove stubborn residues such as layers of a dried substance. Tank cleaners in this category generally use high pressure and/or high flow and spin at slow rotational speeds to maintain high impact. Solid stream nozzles are used to maximize impact. Medium impact cleaning is required when good impingement is needed to remove residues. Tank cleaners that provide medium impact generally use solid stream nozzles at medium flows and pressures. Rotational speed is slightly faster than high impact tank cleaners but much slower than free-spinning nozzles to ensure adequate impact on target areas. Low impact cleaning is used for light cleaning when some impact is required. Low flow/medium pressure and high flow/low pressure nozzles are used to achieve low impact cleaning. These nozzles include rotating flat spray nozzles or stationary full cone types. Rinsing is used when distributing cleaning solution throughout the tank without impact provides sufficient cleaning. Rinsing nozzles are typically free-spinning or stationary spray balls.

5 Optimizing Tank Cleaning Operations Six Key Specification Guidelines Once you ve determined which type of tank cleaner or nozzles may be suitable, there are a few other factors to evaluate to ensure you re going to get the cleaning performance you need. Here are a few guidelines to keep in mind as you start to select a specific unit. distance distance, sometimes referred to as throw, is the distance between the spray exiting the nozzle orifice to the spray hitting the target surface. The spray coming from the nozzle should reach the walls of the tank vessel. that reaches the tank surface may not clean heavily soiled areas. The spray loses impact the farther away it gets from the nozzle. Adequate pressure should be supplied to the nozzle to ensure the cleaning liquid is applied with enough impact to remove the residue. distance is usually expressed in terms of tank diameter. If your tank is 20 ft. (6 m) in diameter and 40 ft. (12 m) tall, understand that you will need two tank cleaners that can clean 20 ft. (6 m) or one that can clean up to 40 ft. (12 m). Impact The characteristics of the residue will determine how much impact is required to remove it. If you re not sure, ask for assistance. We have impact data available for many products and decades of experience. Keep in mind that you can increase impact by increasing flow rate or by increasing pressure. Increasing flow rate is far more effective. Doubling flow rate increases impact by as much as 100% while doubling pressure provides a 40% increase. However, the best approach is to select the tank cleaning product that has adequate impact to ensure optimal cleaning efficiency. Relative Impact Flow Rate Pressure Relative Impact 13 gpm (50 l/min) 13 gpm (50 l/min) 45 psi (3 bar) 90 psi (6 bar) gpm (100 l/min) 45 psi (3 bar) ft. (6 m) 20 ft. (6 m) Another consideration is the effect of rotational speed on impact. Faster rotational speeds can compromise impact and efficiency. The spray rotates so fast that energy dissipates and the spray pattern deteriorates before it hits the tank surface. In some operations, you may be able to eliminate using hot water by increasing impact. This is dependent on the residue to be removed. Increasing impact instead of heating your cleaning solution can save thousands of dollars annually by decreasing energy costs.

6 Optimizing Tank Cleaning Operations Flow rate Operating at the lowest possible flow rate will help keep operating costs down. Less liquid, effluent for disposal and energy will be consumed. A general guideline is to use between 0.2 gal/min/ft 2 (7 l/min/m 2 ) and 0.4 gal/min/ft 2 (15 l/min/m 2 ). This guideline generally applies to stationary nozzles where all the surfaces of the tank are sprayed at the same time. s that rotate usually contact part of the tank at one time and can operate at lower flows. Coverage coverage from tank cleaning nozzles range from 65 to 360. You may need to use more than one nozzle to reach all areas of the tank especially if there is equipment in the tank such as a mixer or agitator. pattern Solid stream sprays provide the greatest impact, followed by flat fan and full cone sprays. Solid Stream for High-Impact coverage Flat Fan for Medium-Impact Full Cone for Low-Impact Materials Most tank cleaning nozzles are constructed of stainless steel because of its durability and resistance to high temperatures. For operations where corrosion is a concern, choose nozzles made of PTFE or PVDF. Make sure units with seals and o-rings are made of materials compatible with the cleaning solution

7 Optimizing Tank Cleaning Operations Optimizing Performance Keep tank cleaning nozzles and fluid-driven machines free of debris by using strainers Particulates in the liquid can clog nozzles, stop rotation and cause inadequate cleaning. Filtering the liquid with line strainers can prevent clogging and extend the wear life of downstream equipment. For fine straining, woven wire mesh screens provide very small openings to strain particulates down to 200 mesh (74 microns) The mesh screen should be made of stainless steel for strength and corrosion resistance Be sure to keep an extra screen on hand for every strainer to ensure trouble-free operation See our bulletin on strainers for recommendations on selecting strainers and mesh. Ensure proper liquid flow by using lances If fluid isn t delivered efficiently and effectively to the tank cleaning device or the nozzle isn t precisely positioned in the tank, cleaning performance will be compromised. Evaluate your lance requirements when specifying your tank cleaner or nozzle. Determine if a standard lance or custom lance is required. Consider a custom lance if you need to position nozzles so the spray impacts directly on heavily soiled areas or skim lines or require special connections, lengths or materials Working with a single supplier will ensure compatibility and eliminate connection problems See our bulletin on lances for more information.

8 Optimizing Tank Cleaning Operations Improve cleaning by changing spray head position Use an adjustable ball fitting to clean vessels in sections. Clean the top half of the vessel; then lower the device and clean the bottom half of the vessel and/or change the angle to clean difficult locations. Reduce the number of cleaning cycles Simple adjustments to pressure and flow may enable a reduction in the number of cycles needed for thorough cleaning. Minimize striping Motor- and fluid-driven tank cleaners provide 360 coverage. However, the solid stream sprays do not overlap as they rotate so there is a small distance between the sprays. The greater the distance the nozzles are from the tank walls, the greater the distance between the sprays. This distance between the sprays causes a striping effect. The best way to minimize striping is to use a three- or four-nozzle hub rather than the standard two-nozzle hub. Striping will be minimized. Recirculate and save Consider recycling your cleaning solution if you aren t using hazardous materials and your water is free of debris. Activate cleaning with the flip of a switch Hard piping your tank cleaner in place can save time and reduce labor costs. Consider permanently installing the device as long as the material or temperature of the material won t damage the cleaning equipment. Striping effect with two-nozzle hub Striping effect with four-nozzle hub Free tank cleaning evaluation Once you ve reviewed this bulletin, you should consider taking advantage of our complimentary, on-site tank cleaning evaluation. One of our tank cleaning specialists will visit your plant and observe your operations. If tank cleaning nozzles are in use, we will inspect the nozzles and evaluate the type, placement and position We will document flow rates, operating pressures, cleaning fluids and residues being removed After the evaluation we will provide a written report summarizing your current operations and recommendations to improve cleaning efficiency Contact your local sales engineer for more information. Call SPRAY or

9 Optimizing Tank Cleaning Operations About ing Systems Co. ing Systems Co. is the world leader in spray technology. It offers the broadest product line in the industry including tank cleaning equipment, spray nozzles, spray controllers, spray injectors and lances and research and testing services. Founded in 1937 in Chicago, Illinois, the company now has 10 manufacturing locations and 90 sales offices around the world. ing Systems Co. recently formed a strategic alliance with Cloud-Sellers, a leader in tank cleaning equipment. The alliance enables ing Systems Co. to offer a wider range of products and Cloud-Sellers to benefit from increased distribution. The Cloud-Sellers products are now branded as part of ing Systems Co. s TankJet line Catalog 15 - Introduction

10 Quick Reference Guide Max Tank Diameter ft (m) Operating Principle Operating Pressure psi (bar) Flow Rate Range gpm (l/min) Coverage Min Tank Opening Size in (mm) Max Temperature F ( C) TankJet D41800E 12 (3.7) Fluid Driven Constant Speed (2-16) (12-128) (32) 300 (150) TankJet 6353 & 6353-MFP 10 (3.0) Fixed Stationary ( ) (35-301) (152) 212 (100) TankJet AA090 Motor Driven (7-35) (5.7-28) (59) 200 (93) TankJet 18250A 8 (2.4) Fluid Driven Reactionary Force (1-4) (48-205) (60) 350 (177) TankJet Fluid Driven Reactionary Force (0.7-4) (7.8-18) 180 up/down, ~360 1 (25) 200 (93) TankJet D41892 TankJet D (2.0) Fluid Driven Reactionary Force Fluid Driven Reactionary Force (1.4-5) (1-4) ( ) (9.5-28) up/down, (37) Thread: 1 (25); CIP version: 2 (50) 160 (70) 300 (149) TankJet 21400A 5 (1.5) Fluid Driven Reactionary Force (1-4) (23-82) (60) 350 (177) TankJet VSM Fixed Stationary (0.7-10) ( ) 240 down 2 (51) 200 (93) TankJet Fluid Driven Reactionary Force (1.5-12) (14-79) 360, Side 1.03 (26) 350 (177) TankJet (0.9) Fixed Stationary (1-10) (23-91) 210, (51) 212 (100) TankJet Fluid Driven Reactionary Force (1-4) ( ) Side 1.03 (26) 200 (93) TankJet (0.6) Fixed Stationary (5-10) (23-43) 210, (51) 212 (100) 0211 Catalog 15 - Quick Reference Guide

11 Quick Reference Guide Max Tank Diameter ft (m) Operating Principle Operating Pressure psi (bar) Flow Rate Range gpm (l/min) Coverage Min Tank Opening Size in (mm) Max Temperature F ( C) TankJet (30) Fluid Driven Turbine (2.8-24) ( ) (158.7) 250 (121) TankJet 180 Fluid Driven Turbine (2.8-24) ( ) (311) 250 (121) TankJet AA (24.4) Motor Driven (3.5-17) (85-757) (184) for 2 nozzle; 8.25 (210) for 4 nozzle 200 (93) TankJet AA190-HP5 Motor Driven (35-350) ( ) (95) for 2- or 4-nozzle hub 350 (177) TankJet (15.2) Fluid Driven Turbine ( ) ( ) (165) for 2 nozzle; 12.5 (318) for 3 nozzle 250 (121) TankJet (12.2) Fluid Driven Turbine ( ) ( ) (190) 250 (121); 500 (260) hightemperature version TankJet AA (10.4) Motor Driven (7-70) ( ) 180, (95) for 360 ; 4.5 (114.3) for (93) TankJet (9.1) Fluid Driven ( ) 8-33 (30-125) (76.2) for 2 nozzle; 3.75 (95.2) for 4 nozzle 350 (121) TankJet & 27500R 25 (7.6) Fluid Driven Reactionary Force ( ) ( ) 180 up/down, 270 up/down, (51-178) 200 (93) TankJet (6.7) Fixed Stationary ( ) ( ) 360 and custom spray angles 10 (254) 212 (100) TankJet D26984 & D (6.0) Fluid Driven Constant Speed (2-16) (12-128) 65 down, 120 down, 180 up/down, 260 up/down, (56) 160 (70) TankJet & 28500R 18 (5.5) Fluid Driven Reactionary Force ( ) 9-78 (34-295) 180 up/down, 270 up/down, (64-102) 200 (93) TankJet (4) Fixed Stationary (1-2.8) (83-192) (38-102) 400 (204)

12 100' Solutions for Tanks Up to 100' (30 m) in Dia. (30 m) s Control Analysis Fabrication

13 TankJet 360 Fluid Driven Tank Cleaner 100' (30 m) TankJet 360 Fluid Driven Tank Cleaner High-Impact, High-Efficiency Cleaning for Hard-to-Remove Residues Features and Benefits Outperforms other fluid driven tank cleaners with more consistent impact over the entire pressure range High-impact cleaning results in shorter cycle times so tanks are returned to service more quickly nozzles rotate 360 in horizontal and vertical planes creating a crisscrossing pattern to thoroughly clean tanks and remove the stickiest of residues Food-grade, oil-lubricated or flow-through gearbox designs Choice of dual- or triple-nozzle hubs No motors TankJet 360 tank cleaners are fluid-driven Sleek and compact fits in small tank openings Choice of standard clutch version or optional pin version. With clutch version, nozzle hub easily rotates by hand for insertion and removal from tank. Use pin version for permanent or CIP installations. Optional external, self-rinse nozzles available for both pin and clutch versions Lightweight for easy portability Customizable to your operation. TankJet 360 can be used for high-concentration chemical recirculation cleaning or low pressure, high-volume cleaning. All units are built-to-order Built-in strainer minimizes clogging and extends wear life User-serviceable for easy maintenance For flow rates below 30 gpm (113.5 l/min) use TankJet 363 tank cleaners with low flow patented technology to reduce wastewater costs. Contact your local sales engineer for more information Great value TankJet 360 is competitively priced, provides better performance and comes with the applications expertise and support of the world s leader in spray technology TankJet 360 tank cleaner for tanks up to 100 (30 m) in dia. Coverage 360 Ideal for Cleaning: Blenders Brewery tanks Food processing vats and tanks Petrochemical/chemical processing reactors Pulp storage chests Processing tanks Tanker trucks Wine vats Try Before You Buy: Ask About Our Free 15-Day Trial Program

14 100' (30 m) TankJet 360 Fluid Driven Tank Cleaner Specifications Max. tank dia.: 100 (30 m) Flow rate range: 30 to 300 gpm (113.5 to I/min) Dual Configuration 6.25" (158.7 mm) MIN. OPENING Pressure range: Wash cycle time: Max. operating temp.: Min. tank opening size: Inlet conn.: Materials of construction: Weight: 40 to 350 psi (2.8 to 24 bar) 10 to 30 min 250 F (121 C) Dual nozzle: 6.25 (15.9 cm) Triple nozzle: (26 cm) 2 NPT (F) with 2-1/2 quick-disconnect (M) 2 NPT (F) with 2-1/2 NST (NH) hose thread (M) 2 BSPT (F) with 2-1/2 quick-disconnect (M) Castings 316 stainless steel Gears 17-4ph stainless steel O-rings self-lubricating EPDM or Viton Seals high-performance spring-energized PTFE Gear shaft bearing system PTFE or oilite bearing All other metallurgy 316 stainless steel 25 lbs (11.3 kg) Triple Configuration 10.25" (260.3 mm) MIN. TANK OPENING 13.3" (338.1 mm) Viton is a registered trademark of DuPont Performance Elastomers. 13.3" (338.1 mm) 0211 Catalog 15 - TankJet 360

15 80' Solutions for Tanks Up to 80' (24.4 m) in Dia. (24.4 m) s Control Analysis Fabrication

16

17 TankJet 180 Fluid Driven Tank Cleaner 80' (24.4 m) TankJet 180 Fluid Driven Tank Cleaner Directional Unit Provides Concentrated, High-Impact Cleaning of Hard-to-Remove Residues Features and Benefits Outperforms other fluid driven tank cleaners more consistent impact over the entire pressure range High-impact cleaning results in shorter cycle times so tanks are returned to service more quickly Provides a concentrated cleaning stream that removes difficult residues and heavy sludges from the bottom and shadow areas of the tanks Ideal for open top tanks nozzles rotate on multiple axes to create a crisscrossing pattern to thoroughly clean tanks and remove the stickiest of residues Food-grade, oil-lubricated or flow-through gearbox designs No motors TankJet 180 tank cleaners are fluid-driven Lightweight for easy portability Customizable to your operation. TankJet 180 can be used for high-concentration chemical recirculation cleaning or low pressure, high-volume cleaning. All units are built-to-order TankJet 180 is designed with built-in strainer to minimize clogging and for long wear life Great value TankJet 180 is competitively priced, provides better performance and comes with the applications expertise and support of the world s leader in spray technology TankJet 180 tank cleaner for tanks up to 80 (24.4 m) in dia. Coverage 180 Down Ideal for Cleaning: Adhesive tanks Food processing vats and tanks Paint tanks Petrochemical/chemical processing reactors Processing tanks Sludge/wastewater tanks Try Before You Buy: Ask About Our Free 15-Day Trial Program

18 80' (24.4 m) TankJet 180 Fluid Driven Tank Cleaner Specifications Max. tank dia.: 80 (24.4 m) Flow rate range: Pressure range: Wash cycle time: Max. operating temp.: Min. tank opening size: Inlet connection: Materials of construction: Height: 30 to 300 gpm (113.5 to I/min) 40 to 350 psi (2.8 to 24 bar) 10 to 30 min 250 F (121 C) (31.1 cm) 2 NPT (F) with 2-1/2 quick-disconnect (M) 2 NPT (F) with 2-1/2 NST hose thread (M) 2 BSPT (F) with 2-1/2 quick-disconnect (M) Castings 316 stainless steel Gears 17-4ph stainless steel O-rings self-lubricating EPDM or Viton Seals high-performance spring-energized PTFE Gear shaft bearing system PTFE or oilite bearing All other metallurgy 316 stainless steel 12.2 (31 cm) TankJet 180 tank cleaner Width including nozzle housing: (30.8 cm) Weight: 29 lbs (13.17 kg) Viton is a registered trademark of DuPont Performance Elastomers Catalog 15 - TankJet 180

19 TanKJet AA290 Motor Driven Tank Cleaner 80' (24.4 m) TankJet AA290 Motor Driven Tank Cleaner Consistent High-Impact Cleaning Day-In and Day-Out Features and Benefits Explosion-proof electric motor Air motor Dependable, durable motor-driven units provide powerful cleaning and remove the most stubborn residues Customize to your cleaning operation. Choose: CE-rated air (AG) or explosion-proof (EP) electric motor Two- or four-nozzle hub 3, 4 or 6 (.9, 1.2 or 1.8 m) shaft length Plus, change flow rates through nozzle selection or adjustments to inlet pressure Motor positioned outside of tank for longer life and fewer failures due to exposure to harmful cleaning solutions TankJet AA290EP and AA290AG tank cleaners for tanks up to 80 (24.4 m) in dia. Long-life construction features corrosion-resistant 316 stainless steel and PTFE fluoropolymer resin seals Optimum impact provided by series solid stream nozzles: with stabilizer vanes that can be removed for maintenance purposes Specifications Max. tank dia.: 80 (24.4 m) Flow rate range: 22 to 200 gpm (85 to 757 l/min) Pressure range: 50 to 250 psi (3.5 to 17 bar) Max. operating temperature: 200 F (93 C) Min. tank opening size: 7.25 (184 mm) for two-nozzle hub 8.25 (210 mm) for four-nozzle hub coverage: 360 Inlet conn.: Flanges: Motor: 2 NPT or BSPT (F) 8 (203 mm) flange for two-nozzle hub 10 (254 mm) for four-nozzle hub Air, explosion-proof electric Shaft lengths: 3, 4 or 6 (.9, 1.2 or 1.8 m) Coverage 360 Ideal for Cleaning: Lubricator assembly is included with the air (AG) model only. Regular lubrication of the air supply line will significantly increase the life of the air motor. Fermentation and yeast tanks and vats Flour silos Mixing tanks Paint tanks

20 80' (24.4 m) TanKJet AA290 Motor Driven Tank Cleaner Performance Data No. Total Flow of Two s (Equal Capacity) gpm or l/min Liquid Inlet Pressure* Double flow rates when using four nozzles up to 200 gpm (752 l/min) 50 psi (3.5 bar) 100 psi (7 bar) 150 psi (10 bar) 200 psi (15 bar) 250 psi (17 bar) H3/4U (85) 32 (121) 39 (144) 45 (177) 50 (188) H3/4U (171) 63 (241) 77 (288) 89 (353) 100 (376) H3/4U (213) 79 (301) 97 (360) 112 (441) 125 (470) H3/4U (298) 111 (422) 136 (505) 157 (618) 175 (658) H3/4U (341) 126 (482) 155 (577) 179 (706) 200 (752) *Note: Liquid inlet pressure measured near inlet connection of tank cleaner. Cycle Time Data Air Motor (AG) Dimensions and Weights Air Motor (AG) Air Pressure psi (bar) Air Consumption scfm (l/sec) Approx. Speed (rpm) 50 psi (3.4 bar) 250 psi (17.2 bar) Approx. Time for One Complete Cycle (min.) 50 psi (3.4 bar) 250 psi (17.2 bar) Model No. AA290AG_F3 Extension Length 3' (0.9 m) Overall Length 60-7/8" (1.5 m) Weight with 8" Flange 56 lbs (25.5 kg) Weight with 10" Flange 63 lbs (28.7 kg) 12 (0.83) 4.7 (2.2) (0.97) 5.4 (2.5) AA290AG_F4 4' (1.2 m) 72-7/8" (1.8 m) 60 lbs (27.3 kg) 67 lbs (30.5 kg) 16 (1.10) 6.3 (3.0) (1.24) 7.1 (3.4) 9 7 AA290AG_F6 6' (1.8 m) 96-7/8" (2.5 m) 69 lbs (31.4 kg) 76 lbs (34.6 kg) Cycle Time Data Explosion-Proof Motor (EP) Dimensions and Weights Explosion-Proof Motor (EP) Approx. Speed (rpm) 4 Supply 120 VAC 60 Hz Approx. Time for One Complete Cycle (min.) 16 Model No. AA290E_F-EP3 Extension Length 3' (0.9 m) Overall Length 61-3/4" (1.6 m) Weight with 8" Flange 66 lbs (30.1 kg) Weight with 10" Flange 73 lbs (33.2 kg) AA290E_F-EP4 4' (1.2 m) 73-3/4" (1.8 m) 70 lbs (31.9 kg) 77 lbs (35.0 kg) AA290E_F-EP6 6' (1.8 m) 97-3/4" (2.5 m) 79 lbs (36.0 kg) 86 lbs (39.1 kg) Head Tank Diameter Opening with Two s Head Tank Diameter Opening with Four s 7.25" (184 mm) Opening 8.25" (210 mm) Opening 1.6" (40 mm) 1.96" (50 mm)

21 TanKJet AA290 Motor Driven Tank Cleaner 80' (24.4 m) Flange Specifications O.D. Bolt Hole Dia. O.D. Bolt Hole Dia. Bolt Circle Dia. Bolt Circle Dia. 8 flange 10 flange Flange Size Flange O.D. Bolt Circle Diameter No. of Flange Holes Bolt Hole Diameter Thickness 8 flange /8 10 flange /8 Ordering Information TankJet AA290AG Tank Cleaner Tank Cleaner No. AA290AG 8F H 3/4 U 316SS I I I I I I I I I Tank Cleaner 8" Flange Extension Length Hub (No. of s) Add B after AA in the tank cleaner type and prior to nozzle type prefix for BSPT connections. Prefix Inlet Conn. Material Code Capacity Size TankJet AA290E-EP Tank Cleaner Tank Cleaner No. AA290E 10F EP H 3/4 U 316SS I I I I I I I I I I Tank Cleaner 10" Flange Explosion-proof Motor Extension Length Hub (No. of s) Add B after AA in the tank cleaner type and prior to nozzle type prefix for BSPT connections. Prefix Inlet Conn. Material Code Capacity Size 0211 Catalog 15 - AA290

22 TankJet 80 Fluid Driven Tank Cleaner 50' (15.2 m) TankJet 80 Fluid Driven Tank Cleaner Powerful, Reliable Cleaning of Tanks up to 50 (15.2 m) in dia. Features and Benefits Units are available with two or three nozzles. Both versions can be equipped with optional clean-in place nozzle as shown on the right. Ideal for cleaning large tanks, tanker trucks and fermenters with minimal maintenance cost Solid stream nozzles rotate in multiple axes to provide complete 360 coverage of entire tank every 45 revolutions Fluid driven, turbine driven with external gears indexes the nozzles with each rotation. Slow, rotating speed provides excellent dwell time on tank surface and improves cleaning Simple design is easy to maintain Mount permanently or move from tank to tank TankJet 80 tank cleaners for tanks up to 50 (15.2 m) in dia. Available with two or three nozzle hub Lightweight weighs only 15 lbs. (6.8 kg) Self -cleaning, flow-through design Optional external CIP nozzle helps clean unit and drop pipe Coverage 360 Ideal for Cleaning: Brewery tanks Chemical vessels Fermenters Food and dairy tanks Tanker trucks Specifications Flow rate range: Pressure range: Max. operating temperature: Rotation speed: Min. tank opening size: coverage: 360 Inlet conn.: Weight: Materials: s: Two-nozzle version: 50 to 95 gpm (189 to 360 l/min) Three-nozzle version: 60 to 125 gpm (227 to 473 l/min) 60 to 150 psi (4.1 to 10.3 bar) 250 F (121 C) 3 to 20 RPM Two-nozzle version: 6.5 (165.1 mm) Three-nozzle version: 12.5 (317.5 mm) 1-1/2 NPT or BSPT (F) 15 lbs. (6.8 kg) 316SS, PTFE, UHMW-PE Two:.375 (9.5 mm) or.438 (11.1mm) orifice Three:.313 (7.8 mm) or.375 (9.5 mm) orifice

23 50' (15.2 m) TankJet 80 Fluid Driven Tank Cleaner Performance Data No. 60 psi (4.1 bar) 70 psi (4.8 bar) 80 psi (5.5 bar) 90 psi (6.2 bar) Capacity gpm (l/min) 100 psi (6.9 bar) 110 psi (7.6 bar) 120 psi (8.3 bar) 130 psi (9.0 bar) 140 psi (9.7 bar) 150 psi (10.3 bar) TJ TJ CIP 50 (189) 57 (216) 62 (235) 65 (246) 68 (257) 73 (276) 76 (288) 79 (299) 83 (314) 86 (326) TJ TJ CIP 63 (238) 67 (254) 72 (273) 75 (284) 79 (299) 83 (314) 85 (322) 88 (333) 92 (348) 95 (360) TJ SR TJ TJ CIP 60 (227) 63 (238) 65 (246) 68 (257) 73 (276) 76 (288) 78 (295) 82 (310) 85 (322) 88 (333) TJ TJ SR 94 (356) 97 (367) 100 (379) 103 (390) 107 (405) 111 (420) 114 (431) 118 (447) 121 (458) 125 (473) TJ SRCIP Dimensions 3.7 (94 mm) TankJet 80-2 TankJet (165.1 mm) 12.5 (317.5 mm) (323.9 mm) (323.9 mm) (298.5 mm) Ordering Information TankJet 80 Tank Cleaning TJ80 * SR CIP I I I I I I Model No. Inlet Model Orifice Size * Add B for BSPT connections. If NPT connection, leave blank. Slow Rotation Clean In Place Typically used in the brewery industry, clean-in place (CIP) nozzles clean unit and down pipe Catalog 15 - TankJet 80

24 40' Solutions for Tanks Up to 40' (12 m) in Dia. (12 m) s Control Analysis Fabrication

25 TankJet 65 FLUID DRIVEN TANK CLEANER 40' (12.2 m) TankJet 65 FLUID DRIVEN TANK CLEANER Thorough, Efficient, Dependable Cleaning Features and Benefits Solid stream nozzles rotate in multiple axes to provide complete 360 coverage of entire tank every 45 revolutions Four-nozzle hub provides tight cleaning pattern and fast cycle times High-temperature version made of all stainless steel can withstand temperatures up to 500 F (260 F) Fluid driven, turbine driven with external gears indexes the nozzles with each rotation. Slow, rotating speed provides excellent dwell time on tank surface Simple self-cleaning, flow-through design Easy to maintain no internal reduction gears Can be permanently mounted or moved from tank to tank Lightweight weighs only lbs. (5.3 kg) Ideal for cleaning: Brew kettles Chemical processing tanks Dairy vessels Food processing vats dryers Tanker trucks Coverage 360 TankJet 65 tank cleaners for tanks up to 40 (12.2m) in dia. Specifications Max. tank dia.: 40 (12.2 m) Standard version: 30 to 100 gpm (114 to 379 l/min) Flow rate range: High-temperature version: 65 to 150 gpm (246 to 568 l/min) Pressure range: 50 to 150 psi (3.4 to 10.3 bar) RPM range: Max. operating temperature: Min. tank opening size: coverage: 360 Inlet conn.: Materials: s: 5 to 40 RPM Standard version: 250 F (121 C) High-temperature version: 500 F (260 C) 7.5 (191 mm) 1-1/2 NPT or BSPT (F) Standard version: Stainless steel, PTFE, UHMW-PE, nylon High-temperature version: all stainless steel Four:.250 (6.4 mm) or.313 (7.9 mm) or.375 (9.5 mm)

26 40' (12.2 m) TankJet 65 FLUID DRIVEN TANK CLEANER Performance Data Model No. 50 psi (3.4 bar) 70 psi (4.8 bar) 90 psi (6.2 bar) Capacity gpm (l/min) 100 psi (6.9 bar) 110 psi (7.6 bar) 130 psi (9.0 bar) 150 psi (10.3 bar) TJ (114) 39 (148) 45 (170) 49 (185) 53 (201) 58 (220) 63 (238) TJ (193) 60 (227) 70 (265) 74 (280) 79 (299) 85 (322) 92 (348) TJ (220) 69 (261) 78 (295) 83 (314) 88 (333) 94 (356) 100 (379) TJ HT 65 (246) 78 (295) 90 (341) 96 (363) 100 (379) 109 (413) 116 (439) TJ HT 67 (254) 83 (314) 97 (367) 103 (390) 107 (405) 117 (443) 126 (477) TJ HT 86 (326) 105 (397) 119 (450) 125 (473) 130 (492) 143 (541) 150 (568) Dimensions 7.5 (190.5 mm) (260.4 mm) 6.63 (168.4 mm) Ordering Information TankJet 65 Tank Cleaner TJ65 * 375 HT I I I I Model No. Inlet Orifice Size * Add B for BSPT connections. If NPT connection, leave blank. High Temperature 0211 Catalog 15 - TankJet 65

27 TankJet AA190 Motor Driven Tank Cleaner 34' (10.4 m) TankJet AA190 Motor Driven Tank Cleaner Motorized Units Provide Thorough, Quick Cleaning and Trouble-Free Operation Features and Benefits Versatile high-impact tank cleaner provides efficient, consistent, reliable cleaning with virtually no maintenance Many options allow easy customization for your cleaning operation. Choose: Variable speed CE-approved air (AG), electric (E) or explosion-proof (EP) electric motor Standard versions that operate at pressures up to 500 psi (35 bar) High-pressure versions that operate at pressures up to 1000 psi (70 bar) for higher impact 360 or 180 coverage 3, 4 or 6 (.9, 1.2 or 1.8 m) shaft length Flange type standard, 150# raised face or sanitary tri-clamp flange Motor is positioned outside the tank away from harmful caustics Lightweight can be installed permanently or easily moved from tank to tank Long wear life materials of construction corrosion-resistant 316 stainless steel and PTFE fluoropolymer resin seals Ideal for Cleaning: Chemical reactors Food processing tanks and vats Paint tanks Pharmaceutical processing vessels Process tanks Tanker trucks Coverage Specifications Max. tank dia.: Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: 25 (7.6 m) for standard versions; 34' (10.4 m) for high-presure versions 3.1 to 44 gpm (11.8 to 170 l/min) for standard versions; 7 to 20 gpm (26 to 78 l/min) for high-pressure versions 100 to 500 psi (7 to 35 bar) for standard versions; high-pressure versions up to 1000 psi (70 bar) 200 F (93 C) coverage: 360 or 180 Inlet conn.: Motor: TankJet AA190DAG tank cleaners provide 180 coverage and are available in standard and high-pressure versions TankJet AA190 tank cleaners for tanks up to 34 (10.4 m) in dia. TankJet AA190EP tank cleaners feature an electric, explosion-proof motor and provide 360 coverage 3.75 (95 mm) for units providing 360 coverage; 4.5 (114.3 mm) for units providing 180 coverage 1 NPT or BSPT (F) TankJet AA190AG tank cleaners provide 360 coverage and are available in standard and high-pressure versions Lubricator assembly is included with the air (AG) model only. Regular lubrication of the air supply line will significantly increase the life of the air motor. Air, electric, explosion-proof electric Shaft lengths: 3, 4 or 6 (.9, 1.2 or 1.8 m)

28 34' (10.4 m) TankJet AA190 Motor Driven Tank Cleaner Performance Data AA190 Tank Cleaners No. Total Flow of Two s (Equal Capacity) gpm or l/min Liquid Inlet Pressure* 100 psi (7 bar) 200 psi (15 bar) 300 psi (20 bar) 400 psi (30 bar) 500 psi (35 bar) 700 psi (50 bar)** 1000 psi (70 bar)** 1/4MEG (11.8) 4.4 (17.3) 5.4 (20) 6.3 (24) 7.0 (26) 8.2 (32) 9.8 (38) 1/4MEG (17.9) 6.6 (26) 8.1 (30) 9.4 (37) 10.5 (40) 12.4 (48) 14.9 (57) 1/4MEG (24) 8.8 (35) 10.8 (40) 12.4 (49) 13.9 (53) 16.4 (63) 19.6 (75) 1/4MEG (29) 10.9 (43) 13.3 (50) 15.4 (61) 17.2 (66) 20 (78) 1/4MEG (35) 12.9 (51) 15.8 (59) 18.2 (72) 20 (78) 1/4MEG (40) 14.8 (59) 18.1 (68) 21 (83) 23 (90) 1/4MEG (45) 16.7 (66) 20 (76) 24 (93) 26 (101) 1/4MEG (54) 20 (79) 25 (92) 28 (112) 32 (121) 1/4MEG (63) 23 (92) 28 (102) 33 (129) 37 (140) 1/4MEG (70) 26 (102) 32 (118) 37 (144) 41 (156) 1/4MEG (76) 28 (111) 34 (128) 40 (157) 44 (170) *Note: Flow rates tabulated above include pressure drop through unit. ** High-pressure versions only. For additional performance data on high-pressure units, contact your local representative. Cycle Time Data Air Motor* (AG, DAG) Cycle Time Data Electric Motor (E and EP) Air Pressure psi (bar) Air Consumption scfm (l/min) Approx. Speed (rpm) 50 psi (3.45 bar) 500 psi (34.48 bar) Approx. Time for One Complete Cycle (min.) 50 psi (3.45 bar) 500 psi (34.48 bar) 6 (0.41) 3.74 (105.8) (0.55) 4.72 (133.6) (0.69) 5.84 (65.3) *For standard and high-pressure versions. Motor Electric Explosion- Proof AC Frequency Speed (rpm) Current (amps) Power (watts) Approx. Time for One Complete Cycle (min.) 50 Hz Hz Hz Hz AA190 Head Tank Diameter Opening with Two s 3.75" (95 mm) Opening AA190D Head Tank Diameter Opening with Two s 4.4" (112.5 mm) 3.4" (86.3 mm) 4.5" DIA (114.3 mm) 3.6" (85 mm) 2.6" (66 mm) 2.0" DIA (5.8 mm) 1.3" (33 mm) 3.0" (76 mm) 4.75" (114.3 mm) Opening AA090

29 TankJet AA190 Motor Driven Tank Cleaner 34' (10.4 m) Dimensions and Weights Model No. Extension Length Overall Length Weight Standard Three-Prong Mounting Flange AA190AG, AA190AGH* 3' (0.9 m) 54-1/4" (1.4 m) 14 lbs. (6.4 kg) 4' (1.2 m) 66-1/4" (1.7 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 90-1/4" (2.3 m) 18-1/2 lbs. (8.4 kg) AA190DAG, AA190DAGH* 3' (0.9 m) 55" (1.4 m) 14 lbs. (6.4 kg) 4' (1.2 m) 67 (1.7m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 91 (2.3 m) 18-1/2 lbs. (8.4 kg) Ordering Information AA190 With Standard Three-Prong Flange Tank Cleaner No. AA190DAGH 3 + 1/4 MEG 0010 I I I I I Tank Cleaner Extension Length Inlet Conn. Capacity Size AA190E AA190E-EP 3' (0.9 m) 48-7/8" (1.2 m) 14 lbs. (6.4 kg) 4' (1.2 m) 60-7/8" (1.5 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 84-7/8" (2.1 m) 18-1/2 lbs. (8.4 kg) 3' (0.9 m) 51-7/8" (1.3 m) 14 lbs. (6.4 kg) 4' (1.2 m) 63-7/8" (1.6 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 87-7/8" (2.2 m) 18-1/2 lbs. (8.4 kg) *H indicates high-pressure version. Dimensions and Weights 150# Raised Face Flange Available in 3" and 4". Model No. Extension Length Overall Length Weight 3' (0.9 m) 54-1/4" (1.4 m) 24-1/2 lbs. (11.1 kg) AA190AG3F 4' (1.2 m) 66-1/4" (1.7 m) 26 lbs. (11.8 kg) 6' (1.8 m) 90-1/4" (2.3 m) 29 lbs. (13.2 kg) 3' (0.9 m) 48-7/8" (1.2 m) 24-1/2 lbs. (11.1 kg) AA190E3F 4' (1.2 m) 60-7/8" (1.5 m) 26 lbs. (11.8 kg) Ordering Information AA190 With 150# Raised Face Flange Tank Cleaner No. AA190AG 3F 3 + 1/4 MEG 0010 I I I I I I Tank Cleaner 150# Raised Face Flange Extension Length Inlet Conn. Capacity Size AA190AG4F AA190AE4F 6' (1.8 m) 84-7/8" (2.1 m) 29 lbs. (13.2 kg) 3' (0.9 m) 51-7/8" (1.3 m) 29-1/2 lbs. (13.4 kg) 4' (1.2 m) 63-7/8" (1.6 m) 31 lbs. (14.1 kg) 6' (1.8 m) 87-7/8" (2.2 m) 34 lbs. (15.4 kg) 3' (0.9 m) 54-1/4" (1.4 m) 29-1/2 lbs. (13.4 kg) 4' (1.2 m) 66-1/4" (1.7 m) 31 lbs. (14.1 kg) 6' (1.8 m) 90-1/4" (2.3 m) 34 lbs. (15.4 kg) See Accessories Section for Information on Adjustable Flanges, Mounting Kits and Tank Cleaner Adapters.

30 34' (10.4 m) TankJet AA190 Motor Driven Tank Cleaner Dimensions and Weights Model No. Extension Length Overall Length Weight Sanitary Tri-Clamp Flange Available in 3", 4" and 6". AA190AG3SF 3' (0.9 m) 54-1/4" (1.4 m) 14 lbs. (6.4 kg) 4' (1.2 m) 66-1/4" (1.7 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 90-1/4" (2.3 m) 18-1/2 lbs. (8.4 kg) 3' (0.9 m) 48-7/8" (1.2 m) 14 lbs. (6.4 kg) AA190E3SF 4' (1.2 m) 60-7/8" (1.5 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 84-7/8" (2.1 m) 18-1/2 lbs. (8.4 kg) 3' (0.9 m) 54-1/4" (1.4 m) 14-1/4 lbs. (6.5 kg) AA190AG4SF 4' (1.2 m) 66-1/4" (1.7 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 90-1/4" (2.3 m) 18-3/4 lbs. (8.5 kg) 3' (0.9 m) 48-7/8" (1.2 m) 14-1/4 lbs. (6.5 kg) Ordering Information AA190 With Sanitary Tri-Clamp Flange Tank Cleaner No. AA190AG 3SF 3 + 1/4 MEG 0010 I I I I I I Tank Cleaner Sanitary Tri-Clamp Flange Extension Length Inlet Conn. Capacity Size Note: The 3" sanitary flange has a modified hub assembly that can fit through a 2.75" opening with nozzles orientated in vertical position. Add B after AA in the tank cleaner type and prior to nozzle type prefix for BSPT connections. AA190E4SF AA190AG6SF AA190E6SF 4' (1.2 m) 60-7/8" (1.5 m) 15-1/2 lbs. (7 kg) 6' (1.8 m) 84-7/8" (2.1 m) 18-3/4 lbs. (8.5 kg) 3' (0.9 m) 54-1/4" (1.4 m) 17 lbs. (7.7 kg) 4' (1.2 m) 66-1/4" (1.7 m) 18-1/2 lbs. (8.4 kg) 6' (1.8 m) 90-1/4" (2.3 m) 21-1/2 lbs. (9.8 kg) 3' (0.9 m) 48-7/8" (1.2 m) 17 lbs. (7.7 kg) 4' (1.2 m) 60-7/8" (1.5 m) 18-1/2 lbs. (8.4 kg) 6' (1.8 m) 84-7/8" (2.1 m) 21-1/2 lbs. (9.8 kg) See Accessories Section for Information on Adjustable Flanges, Mounting Kits and Tank Cleaner Adapters Catalog 15 - AA190

31 TankJet 75 FLUID DRIVEN TANK CLEANER 30' (9.1 m) TankJet 75 FLUID DRIVEN TANK CLEANER Thorough, Cost-Effective Cleaning of Tanks, Totes and IBCs up to 30 (9.1 m) in dia. Features and Benefits Ideal for medium impact cleaning and provides adequate impingement cleaning of small tanks without the expense of high impact tank cleaners Fluid driven with external gears to reduce speed of nozzles for better impact and cleaning efficiency 360 indexing pattern is completed every 45 revolutions Solid stream nozzles rotate in multiple axes to provide complete coverage of the entire tank Simple design is easy to maintain can be rebuilt quickly and easily in about 5 minutes Mount permanently or move from tank to tank Self-cleaning, flow-through design Long-wearing materials 316 stainless steel, PTFE and UHMWE-PE TankJet 75 tank cleaners for tanks up to 30 (9.1 m) in dia. Choose from two versions: TankJet : Two nozzle hub design Two nozzle size options Fits in a 3 (76. 2 mm) opening TankJet : Four nozzle design provides better coverage and faster cleaning Two nozzle size options Fits in a 3.75 (95.2 mm) opening Coverage 360 Ideal for Cleaning: Chemical containers Dairy tanks and totes Food and beverage tanks Pharmaceutical tanks Process tanks Specifications Model No Flow rate range: Pressure range: 11 to 27 gpm (42 to 102 lpm) 75 to 300 psi (5.2 to 20.7 bar) 8 to 33 gpm (30 to 125 lpm) 50 to 300 psi (3.5 to 20.7 bar) RPM ranges: 10 to 18 RPM 7 to 17 RPM Max. operating temperature: Min. tank opening size: coverage: 250 F (121 C) 3 (76.2 mm) 250 F (121 C) 3.75 (95.2 mm) Inlet conn.: 3/4" NPT, BSPT (F) 3/4" NPT, BSPT (F) s: Weight: Two: 0.234" (5.9 mm) or 0.172" (4.4 mm) orifice 2 lbs (0.9 kg) Four: 0.172" (4.4 mm) or 0.125" (3.2 mm) orifice 3 lbs (1.4 kg)

32 30' (9.1 m) TankJet 75 FLUID DRIVEN TANK CLEANER Performance Data Model No. 50 psi (3.4 bar) 75 psi (5.2 bar) 100 psi (6.9 bar) Capacity gpm (l/min) 150 psi (10.3 bar) 200 psi (13.8 bar) 250 psi (17.2 bar) 300 psi (21 bar) TJ (76) 23 (87) 25 (95) 27 (102) TJ LP 13 (49) 15 (57) 18 (68) TJ (57) 18 (68) 20 (76) 22 (83) TJ LP 11 (42) 13 (49) 15 (57) TJ (87) 29 (110) 31 (117) 33 (125) TJ LP 11 (42) 15 (57) 18 (68) 22 (83) TJ (57) 19 (72) 20 (76) 21 (80) TJ LP 8 (30) 11 (42) 12 (45) 15 (57) Dimensions TankJet TankJet (76 mm) 1.97 (50 mm) 3.75 (95 mm) 1.97 (50 mm) 6.13 (156 mm) 6.13 (156 mm) Ordering Information TankJet 75 Tank Cleaning Machine TJ75 * LP I I I I I Model No. Inlet Model Orifice Size * Add B for BSPT connections. If NPT connection, leave blank. Low Pressure 0211 Catalog 15 - TankJet 75

33 TankJet & 27500R Fluid Driven s 25' (7.6 m) TankJet Fluid Driven s & 27500R PTFE Rotating s Resist Harsh Chemicals and Provide Excellent Cleaning and Rinsing Features and Benefits Especially suited for CIP systems no motor source is needed due to the reactionary force of the cleaning liquid to rotate the spray head Provides more impact than static spray balls Long-life material of construction corrosion- and chemical-resistant PTFE fluoropolymer resin 27500R nozzles in 1/2 and 3/4 inlet connections are available in carbon-filled PTFE for improved thermal characteristics and higher mechanical strength over standard PTFE angles range from 180 to 360 ; can clean certain areas or entire tank interior 27500R has a rotating spray head that can be easily removed from the body for inspection and maintenance To optimize performance of the rotating spray head, use liquid free of debris TankJet 27500R tank cleaning nozzles for tanks up to 25 (7.6 m) in dia. Coverage TankJet tank cleaning nozzle Some TankJet 27500R nozzles available in carbon-filled PTFE 180 Up 270 Up 360 Specifications Max. tank dia.: 25 (7.6 m) Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet conn. TankJet 27500: Inlet conn. TankJet 27500R: 4 to 391 gpm (15.3 to 1490 l/min) 10 to 50 psi (.7 to 3.5 bar) 200 F (93 C) 2 to 7 (51 to 178 mm) depending on capacity size 180 spraying up or down, 270 spraying up or down and 360 1/2 to 3 NPT or BSPT (F) 1/2 to 1 NPT or BSPT (F) A C E 180 Down 270 Down B D Ideal for Cleaning: Broke chests Chemical tanks PCB washers Pharmaceutical tanks Process tanks

34 25' (7.6 m) TankJet & 27500R Fluid Driven s Performance Data No. Orifice Dia. (mm) 10 psi (0.7 bar) 20 psi (1.5 bar) Capacity gpm (l/min) 30 psi (2 bar) 40 psi (3 bar) 50 psi (3.5 bar) Max. Tank Dia. (m) l (A thru E)-R-1/2-8-TEF 3/32" (2.4) 4.0 (15.3) 5.7 (22) 6.9 (26) 8.0 (32) 8.9 (34) 10' (3.0) l (A thru E)-R-3/4-18-TEF 3/32" (2.4) 9.0 (34) 12.7 (50) 15.6 (58) 18 (71) 20 (77) 15' (4.3) (A thru E)-R-3/4-32-TEF 5/32" (4.0) 16 (61) 23 (89) 28 (103) 32 (126) 36 (136) 15' (4.3) (A thru E)-R-3/4-46-TEF 15/64" (6.0) 23 (88) 33 (130) 40 (148) 46 (182) 51 (196) 15' (4.3) (A thru E)-R-1-50-TEF 5/32" (4.0) 25 (95) 35 (140) 43 (161) 50 (197) 56 (215) 18' (5.5) (A thru E)-R-1-70-TEF 7/32" (5.6) 35 (133) 49 (195) 61 (225) 70 (275) 78 (300) 18' (5.5) (A thru E)-R-1-90-TEF 19/64" (7.5) 45 (172) 64 (250) 78 (290) 90 (355) 101 (385) 18' (5.5) (A thru E) TEF 15/64" (6.0) 50 (191) 71 (280) 87 (320) 100 (395) 112 (425) 20' (6.0) (A thru E) TEF 17/64" (6.7) 63 (240) 88 (350) 108 (400) 125 (495) 140 (530) 20' (6.0) (A thru E) TEF 5/16" (7.9) 75 (285) 106 (420) 130 (480) 150 (590) 168 (640) 20' (6.0) (A thru E) TEF 3/8" (9.5) 88 (335) 124 (490) 152 (560) 175 (690) 196 (745) 20' (6.0) (A thru E) TEF 27/64" (10.7) 100 (380) 141 (560) 173 (645) 200 (790) 224 (850) 20' (6.0) (A thru E) TEF 25/64" (9.9) 125 (475) 177 (700) 217 (805) 250 (985) 280 (1065) 25' (7.6) (A thru E) TEF 27/64" (10.7) 150 (570) 212 (840) 260 (965) 300 (1180) 335 (1280) 25' (7.6) (A thru E) TEF 31/64" (12.3) 175 (665) 247 (975) 303 (1130) 350 (1380) 391 (1490) 25' (7.6) l Models available in carbon-filled PTFE. Suggested optimum operating range: 20 to 40 psi (1.5 to 3 bar). Dimensions X Dia. Inlet Dia. X Dia. Y Z Flats 27500, 27500R 1/2" 1-15/16" (49.2 mm) 2-3/8" (60.3 mm) 1-1/8" (28.6 mm) 27500, 27500R 3/4" 2-1/4" (57.2 mm) 2-5/8" (66.6 mm) 1-5/16" (33.3 mm) Y 27500, 27500R 1" 2-3/4" (69.8 mm) 3" (76.2 mm) 1-5/8" (45.3 mm) Z " 4-7/8" (123.8 mm) 4-3/8" (111 mm) 2-3/4" (69.8 mm) " 6-7/8" (174.6 mm) 5-7/8" (149.2 mm) 3-7/8" (98.4 mm) Ordering Information TankJet Tank Cleaning E R 3/4 18 TEF* I I I I I I Coverage Inlet Capacity Conn. Size Removable Head *Indicate CTEF for carbon-filled PTFE. Material Code 0211 Catalog

35 TankJet 14 and 16 Fluid Driven Tank Cleaners 24' (7.2 m) TankJet 14 and 16 Fluid Driven Tank Cleaners Rotating Units Provide Better Cleaning than Static Balls Features and Benefits Similar design and appearance to static spray balls except the units rotate to ensure effective impingement of cleaning solution on tank walls Fluid driven, turbine driven units rotate at slow speeds 3 to 15 rpm for increased dwell time on tank surface compared to free spinning units Solid stream pattern provides full coverage Suitable for CIP or portable installation head is easily removed for inspection and maintenance Made of 316 stainless steel and PTFE materials TankJet 14 tank cleaner for tanks up to 12 (3.6 m) in dia. TankJet 16 tank cleaner for tanks up to 24 (7.2 m) in dia. Choose from two versions: TankJet 14: Fits easily into a 2 Schedule 40 pipe For tanks up to 12 (3.6 m) diameter TankJet 16: Fits easily into a 3 Schedule 40 pipe For tanks up to 24 (7.2 m) diameter Coverage 180 Up 270 Down 360 Specifications Model No. TJ14 TJ16 Flow rate range: Pressure range: 13 to 34 gpm (49 to 129 l/min) 50 to 200 psi (3.4 to 13.8 bar) 30 to 76 gpm (114 to 288 l/min) 50 to 200 psi (3.4 to 13.8 bar) Rotation speed: 3 to 15 RPM 3 to 15 RPM Max. operating temperature: Min. tank opening size: coverage: 250 F (121 C) 2" (51 mm) 360 ; 270 down, 180 up and down 250 F (121 C) 3" (76 mm) 360 ; 270 down, 180 up and down Inlet conn.: 3/4" NPT, BSPT (F) 1-1/2" NPT, BSPT (F) Weight: 2.25 lbs. (1 kg) 4.75 lbs. (2.1 kg) H D C 180 Down G Ideal for Cleaning: Brewery tanks Chemical mixers/blenders Food processing tanks Pharmaceutical tanks Totes/IBCs Wine tanks

36 24' (7.2 m) TankJet 14 and 16 Fluid Driven Tank Cleaners Performance Data Model No. Coverage 50 psi (3.4 bar) 70 psi (4.8 bar) 90 psi (6.2 bar) 100 psi (6.9 bar) Capacity gpm (l/min) 120 psi (8.3 bar) 140 psi (9.7 bar) 160 psi (11.0 bar) 180 psi (12.4 bar) 200 psi (13.8 bar) D 13 (49) 16 (61) 18 (68) 19.5 (74) 21 (79) 23 (87) 25 (93) 27 (100) 28 (106) TJ-14 G, H 16 (61) 18.5 (70) 21 (79) 23 (87) 24 (91) 26 (98) 28 (106) 30 (114) 32 (121) C 17 (64) 19.5 (74) 22 (83) 25 (93) 26 (98) 28 (104) 30 (112) 32 (121) 34 (129) TJ-16 H 36 (136) 43 (163) 49 (185) 52 (197) 57 (216) 61 (231) 65 (246) 69 (261) 73 (276) D, C, G 40 (151) 47 (178) 53 (201) 55 (208) 60 (227) 65 (246) 69 (261) 74 (280) 76 (288) Dimensions TankJet (50 mm) TankJet (77 mm) 8.98 (228 mm) 6.56 (167 mm) Ordering Information TankJet 14 and 16 Tank Cleaners TJ14 * B I I I Inlet Model No. *Add B for BSPT connections. If NPT connection, leave blank. Coverage 0311 Catalog 15 - TankJet 14 and 16

37 TankJet Fixed Tank Cleaning 22' (6.7 m) TankJet Fixed Tank Cleaning Stationary Cluster s Provide Robust and Reliable Cleaning of Deep Tanks Features and Benefits Features 13 FullJet nozzles to provide high-capacity cleaning Simple, reliable and does not contain any moving parts Can be specially designed for a wide range of coverages To rinse deeper tanks, use Model with a 1-1/2 bottom outlet connection for use with a pipe extension and a TankJet 6353 nozzle assembly TankJet tank cleaning nozzle for tanks up to 22 (6.7 m) in dia. Specifications Max. tank dia.: 22 (6.7 m) Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: Materials: coverage: 360 Inlet conn.: 72 to 385 gpm (280 to 1470 l/min) 20 to 50 psi (1.5 to 3.5 bar) 212 F (100 C) 10 (254 mm) Brass or 316 stainless steel 3 NPT or BSPT (F) Accepts 1/2, 3/4 or 1 FullJet full cone nozzles Coverage 360 Ideal for Cleaning: Chemical tanks Process tanks Pulp chests Tanker trucks TankJet and 6353 for cleaning deeper tanks

38 22' (6.7 m) TankJet Fixed Tank Cleaning Performance Data No. FullJet No. Max. Free Passage in. (mm) 20 psi (1.5 bar) 30 psi (2 bar) Capacity gpm (l/min) 40 psi (3 bar) 50 psi (3.5 bar) /2 1/2 HH (3.6) 72 (280) 86 (320) 99 (390) 109 (415) /4 3/4 HH (5.2) 148 (580) 180 (660) 205 (800) 225 (860) HH (6.4) 252 (1000) 306 (1130) 350 (1370) 385 (1470) Dimensions and Weights No. A B Dia. Weight A / /4 6-17/32" (166 mm) 6-27/32" (174 mm) 7-1/2" (191 mm) 8-1/4" (210 mm) 13.7 lbs. (6.2 kg) 15.3 lbs. (6.9 kg) /32" (183 mm) 9" (229 mm) 18.1 lbs. (8.2 kg) B Ordering Information TankJet Tank Cleaning Assembly /4 316SS + 3/4HH 316SS 7 I I I I I I No. Inlet Conn. Material Code Add B prior to No. and for BSPT connections. Material Code Capacity Size 0211 Catalog

39 20' Solutions for Tanks Up to 20' (6 m) in Dia. (6 m) s Control Analysis Fabrication

40 TankJet D40159 and D26984 Fluid Driven Tank Cleaning s 20' (6 m) TankJet D40159 and D26984 Fluid Driven Tank Cleaning s Constant-Speed s Provide Superior Cleaning and a Choice of Coverages Features and Benefits Features three flat sprays mounted in a rotating spray head driven by the flow of the cleaning liquid Rotates at nearly constant speed of 2 to 30 RPM over a wide range of fluid pressures for more thorough cleaning up to four times higher impact than a conventional rotating nozzle for improved cleaning efficiency Perfect for cleaning, sanitizing and foaming applications; slow controlled rotational speed provides more dwell time on tank surface PVDF nozzle body constructed of chemical and corrosion resistant Kynar with a PTFE washer and a polyethylene sleeve 303 or 316 stainless steel body available with a PTFE sleeve and washer Sanitary tubing and wall mounting options available upon request TankJet D40149 and D26984 tank cleaning nozzles for tanks up to 20 (6 m) in dia. TankJet D40159 and D26984 nozzles are available in stainless steel and PVDF; ATEX-certified explosion-proof models are available in stainless steel Specifications Max. tank dia.: 20 (6.0 m) Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet conn.: 3.2 to 31 gpm (12.0 to 128 l/min) 30 to 230 psi (2 to 16 bar) 160 F (70 C) 2.25 (56 mm) D , 120, 180 and 260 ; D Kynar is a registered trademark of Arkema, Inc. 1/2 NPT or BSPT for stainless steel versions; 3/8 and 1/2 NPT or BSPT for PVDF versions Ideal for Cleaning: Chemical processing tanks Dry powder tanks Food processing tanks Mixing tanks Pharmaceutical tanks

41 20' (6 m) TankJet D40159 and D26984 Fluid Driven Tank Cleaning s D40159 Coverage Angle 260 Down 260 Up** 180 Down 180 Up** 120 Down 65 Down Capacity Size 3.2 l l l 4.5 l l l l 9.9 l l l l l l 13.6 l l l l Note: D40159-SS, -316SS not available in 3.2 capacity. D26984 available in 360 only. Performance Data Inlet 3/8 1/2 PVDF SS, 316SS Capacity Size 30 psi (2 bar) 40 psi (3 bar) Capacity gpm (l/min) 100 psi (5 bar) 150 psi (10 bar) 230 psi (16 bar) l (12) 3.5 (14) 5.3 (17) 6.5 (24) 7.9 (30) l (14.5) 4.4 (17.0) 6.9 (22) 8.5 (32) 10.5 (40) l l (12) 3.5 (14) 5.3 (17) 6.5 (24) 7.9 (30) l l (14.5) 4.4 (17) 6.9 (22) 8.5 (32) 10.5 (40) l l (31.8) 9.7 (40) 15.5 (52) 19.1 (73) 24 (93) l l (42.9) 14.0 (55) 21 (71) 26 (101) 31 (128) Dimensions and Weights A A C B C B PVDF Models 303 and 316 Stainless Steel Models A B Dia. C Dia. Weight A B Dia. C Dia. Weight 5-3/4" (146 mm) 1-15/16" (49 mm) 1-59/64" (49 mm).43 lbs. (0.19 kg) 5-3/4" (146 mm) 2" (50 mm) 1-3/5" (41 mm) 1.62 lbs. (0.73 kg) Ordering Information TankJet D40159 Tank Cleaning D /8 PVDF* A** I I I I I I Inlet Material Capacity Conn. Code Size Angle Dir.. TankJet D26984 Tank Cleaning D /8 PVDF* 3.2 I I I I Inlet Material Conn. Code Capacity Size * Material: Specify PVDF for Chemical Resistant Kynar. Specify SS for Stainless Steel 303 (DIN ). Specify 316SS for Stainless Steel 316 (DIN ). **Add A to the D40159 part number for upward spray toward inlet. Add B prior to the inlet connection for BSPT connections Catalog 15 - D40159

42 TankJet & 28500R Fluid Driven Tank Cleaning s 18' (5.5 m) TankJet & 28500R Fluid Driven Tank Cleaning s Sanitary, Rotating s Resist Harsh Chemicals and Provide Excellent Cleaning Features and Benefits Threadless, tapered design promotes self-draining to prevent build-up on nozzle Well-suited for CIP systems no motor source is needed due to reactionary force of cleaning liquid to rotate spray head Provides more impact than static spray balls Secured to inlet connection with 316 stainless steel locking pin Conforms to 3A sanitary standard for spray cleaning devices to remain in place (does not apply to 180 spraying up coverage) Constructed of PTFE fluoropolymer resin ideal for harsh cleaning chemicals TankJet and 28500R tank cleaning nozzles for tanks up to 18 (5.5 m) in dia. Conforms to 3A standards for CIP 28500R has a rotating spray head that can be easily removed from the body for inspection and maintenance To optimize performance of the rotating spray head, use liquid free of debris Coverage 180 Up 270 Up 360 Specifications Max. tank dia.: 18 (5.5 m) Flow rate range: 9 to 78 gpm (34 to 295 l/min) A C E 180 Down 270 Down Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet conn.: 10 to 50 psi (0.7 to 3.5 bar) 200 F (93 C) 2.5 to 4 (64 to 102 mm) depending on capacity size 180 up or down, 270 up or down and 360 3/4, 1, 1-1/2, DN20, DN25 and DN40 sanitary tubing B D Ideal for Cleaning: Chemical tanks Dairy vats Food processing tanks Pharmaceutical vessels

43 18' (5.5 m) TankJet & 28500R Fluid Driven Tank Cleaning s Performance Data No. Orifice Dia. (mm) 10 psi (0.7 bar) 20 psi (1.5 bar) Capacity gpm (l/min) 30 psi (2 bar) 40 psi (3 bar) 50 psi (3.5 bar) (A thru E)-3/4-18-TEF 0.089" (2.3) 9 (34) 12.7 (50) 15.6 (58) 18 (71) 20.1 (77) (A thru E)-DN20-18-TEF 0.089" (2.3) 9 (34) 12.7 (50) 15.6 (58) 18 (71) 20.1 (77) (A thru E)-3/4-23-TEF 0.110" (2.8) 11.5 (44) 16.3 (64) 19.9 (74) 23 (91) 26 (99) (A thru E)-DN20-23-TEF 0.110" (2.8) 11.5 (44) 16.3 (64) 19.9 (74) 23 (91) 26 (99) (A thru E)-3/4-32-TEF 0.154" (3.9) 16 (61) 22.6 (89) 27.7 (103) 32 (126) 35.8 (136) (A thru E)-DN20-32-TEF 0.154" (3.9) 16 (61) 22.6 (89) 27.7 (103) 32 (126) 35.8 (136) (A thru E)-3/4-46-TEF 0.257" (6.5) 23 (88) 32.5 (128) 39.8 (148) 46 (181) 51.4 (196) (A thru E)-DN20-46-TEF 0.257" (6.5) 23 (88) 32.5 (128) 39.8 (148) 46 (181) 51.4 (196) (A thru E)-1-33-TEF 0.152" (3.9) 16.5 (63) 23 (92) 29 (106) 33 (131) 37 (141) (A thru E)-DN25-33-TEF 0.152" (3.9) 16.5 (63) 23 (92) 29 (106) 33 (131) 37 (141) (A thru E)-1-50-TEF 0.209" (5.3) 25 (95) 35.4 (140) 43.3 (161) 50 (197) 55.9 (213) (A thru E)-DN25-50-TEF 0.209" (5.3) 25 (95) 35.4 (140) 43.3 (161) 50 (197) 55.9 (213) (A thru E)-1-70-TEF 0.266" (6.8) 35 (133) 49.5 (195) 60.6 (226) 70 (276) 78.3 (298) (A thru E)-DN25-70-TEF 0.266" (6.8) 35 (133) 49.5 (195) 60.6 (226) 70 (276) 78.3 (298) (A thru E)-1-1/2-53-TEF 0.201" (5.1) 27 (101) 37 (148) 46 (171) 53 (209) 59 (226) (A thru E)-DN40-53-TEF 0.201" (5.1) 27 (101) 37 (148) 46 (171) 53 (209) 59 (226) (A thru E)-1-1/2-70-TEF 0.266" (6.8) 35 (132) 49 (185) 61 (231) 70 (265) 78 (295) (A thru E)-DN40-70-TEF 0.266" (6.8) 35 (132) 49 (185) 61 (231) 70 (265) 78 (295) Dimensions X Dia. Inlet ID Inlet Dia. X Dia. Y Z Z 3/4".76" 2-1/4" (57.2 mm) 2-5/8" (66.6 mm) 3/8" (9.5 mm) DN mm 2-1/4" (57.2 mm) 2-5/8" (66.6 mm) 3/8" (9.5 mm) Y 1" 1.02" 2-3/4" (69.8 mm) 2-7/8" (73 mm) 1/2" (12.7 mm) DN mm 2-3/4" (69.8 mm) 2-7/8" (73 mm) 1/2" (12.7 mm) 1-1/2" 1.52" 3-5/8" (92 mm) 3-5/8" (92 mm) 3/4" (19 mm) DN mm 3-5/8" (92 mm) 3-5/8" (92 mm) 3/4" (19 mm) Ordering Information Dimensions do not include connection pin length. TankJet Tank Cleaning E R 3/4 23 TEF I I I I I I Coverage Removable Head Inlet Conn. Capacity Size Material Code 0211 Catalog

44 TankJet 9 Fluid Driven Tank Cleaner 16' (4.9 m) TankJet 9 Fluid Driven Tank Cleaner Rotating s Effectively Rinse Tanks Features and Benefits Flat spray nozzles mounted in a rotating spray head driven by the flow of the cleaning liquid Simple and reliable no ball bearings Operates effectively in any position vertical or horizontal Suitable for CIP and sanitary applications Can be used for chemical distribution and passivation Made of 316 stainless steel with thermoplastic bearings Choose from three versions: TankJet 9-A Two flat sprays produce sides sprays 2 x 175 coverage Low flow rates up to 5 gpm (18.9 l/min) For tanks up to 6 (1.8 m) diameter TankJet 9-B Six flat sprays provide 360 coverage of entire tank Flow rates up to 17 gpm (64 l/min) For tanks up to 12 (3.6 m) diameter TankJet 9-C Six flat sprays provide 360 coverage of entire tank High flow rates up to 38 gpm (144 l/min) For tanks up to 16 (4.8 m) diameter Ideal for Cleaning: Brewery tanks Chemical containers Drums and kegs Food processing tanks Pharmaceutical tanks Wine barrels and vats Specifications Model No. TJ9-A TJ9-B TJ9-C Flow rate range: Pressure range: Max, operating temperature: Min. tank opening size: coverage: Inlet conn.: Weight: Coverage TankJet 9 tank cleaners for tanks up to 16 (4.9 m) in dia. 1.3 to 5 gpm (4.9 to 18.9 l/min) 10 to 120 psi (0.7 to 8.3 bar) 190 F (88 C) " (27 mm) 2 x to 17 gpm (18.9 to 64 l/min) 10 to 120 psi (0.7 to 8.3 bar) 190 F (88 C) 1.375" (35 mm) 12 to 38 gpm (45 to 144 l/min) 10 to 120 psi (0.7 to 8.3 bar) 190 F (88 C) 1.625" (42 mm) 2 x /8" NPT, BSPT (F).34 lbs. (.15 kg) 1/2" NPT, BSPT (F).58 lbs. (.26 kg) 3/4" NPT, BSPT (F).96 lbs. (.44 kg)

45 16' (4.9 m) TankJet 9 Fluid Driven Tank Cleaner Performance Data Model No. 10 psi (0.7 bar) 30 psi (2.1 bar) 50 psi (3.4 bar) Capacity gpm (l/min) 70 psi (4.8 bar) 90 psi (6.2 bar) 100 psi (6.9 bar) 110 psi (7.6 bar) 120 psi (8.3 bar) TJ9-A 1.3 (4.9) 2.5 (9.5) 3 (11.4) 4 (15.1) 4.5 (17) 4.7 (17.8) 4.9 (18.5) 5 (18.9) TJ9-B 5 (18.9) 8 (30) 11 (42) 13 (49) 14 (53) 15 (57) 16 (61) 17 (64) TJ9-C 12 (45) 20 (76) 25 (95) 30 (114) 33 (123) 35 (133) 37 (140) 38 (144) Dimensions TankJet 9-C TankJet 9-B TankJet 9-A (59 mm) 3.5 (88 mm) 4 (102 mm) (27 mm) (35 mm) (42 mm) Ordering Information TankJet 9 Tank Cleaner TJ9 * A I I I Model Inlet No. *Add B for BSPT connections. If NPT connection, leave blank Catalog 15 - TankJet 9

46 TankJet & A Fixed Balls 13' (4 m) TankJet & A Fixed Balls Stationary Balls Ideal for Sanitary Rinsing Features and Benefits Suitable for CIP no moving parts Low-cost way to rinse easy-to-remove residues Choice of 180 or 360 spray coverages Can be installed in any position 316L stainless steel construction permits use of a wide array of chemicals A sanitary spray balls: Polished 32Ra interior and exterior surface finish Threadless and self-draining design prevents build-up TankJet A spray balls for tanks up to 13 (4 m) in dia. Specifications Max. tank dia.: 13 (4 m) Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet tube size: 22 to 51 gpm (83 to 192 l/min) 15 to 40 psi (1.0 to 2.8 bar) 400 F (204 C) 3.4 to 4.6 (87 to 118 mm) TankJet TankJet up, 180 down, 360 Custom drilling upon request 3/4, 1 TankJet /4 1, 1-1/2 TankJet A Ideal for Cleaning: Chemical processing tanks Food processing vats and tanks Pharmaceutical vessels Coverage Angle 180 Up 180 Down 360 A B E l A l l l Note: Custom drilling available for A; contact your local sales engineer.

47 13' (4 m) TankJet & A Fixed Balls Performance Data /Size 15 psi (1.0 bar) Capacity gpm (l/min) 22 psi (1.52 bar) 30 psi (2.06 bar) Max. ft (m) 63225E-3/ L 22 (83) 27 (102) 31 (117) 10 (3.0) 63225E L 32 (121) 39 (148) 45 (170) 13 (4.0) /Size 15 psi (1.0 bar) Capacity gpm (l/min) 25 psi (1.7 bar) 40 psi (3 bar) Max. ft (m) 63225E A 31 (115) 40 (151) 51 (192) 10 (3.0) 63225E A 31 (115) 40 (151) 51 (192) 13 (4.0) 63225A A 31 (115) 40 (151) 51 (192) 13 (4.0) 63225E A 31 (115) 40 (151) 51 (192) 13 (4.0) 63225E A 31 (115) 40 (151) 51 (192) 13 (4.0) 63225E A 31 (115) 40 (151) 51 (192) 13 (4.0) Dimensions C F D A E /Size Inlet Tube Size A 63225E-3/ L 3/4" 63225E L 1" Ball Dia. B Length C Length D Length E Pin Dia. F 2" (51 mm) 2.5" (64 mm) 3.64" (93 mm) 4.40" (112 mm).51" (13 mm).51" (13 mm) 1.25 (31.8 mm) 1.56 (39.6 mm).13" (3.3 mm).13" (3.3 mm) B A F A B D E C /Size Inlet Tube Size A 63225E A 3/4" 63225E A 1" 63225A A 1-1/2" 63225E A 1-1/2" 63225E A 1-1/2" 63225E A 1-1/2" Ball Dia. B Length C Length D Length E Pin Dia. F 1-1/2" (38.1 mm) 2" (50.8 mm) 2-1/2" (63.5 mm) 2-1/2" (63.5 mm) 3" (76.2 mm) 4" (101.6 mm) 2-17/32" (64.3 mm) 3-5/16" (84.1 mm) 4-1/4" (108 mm) 4-1/4" (108 mm) 4-25/32" (121.4 mm) 5-3/4" (146 mm) 3/8" (9.5 mm) 3/8" (9.5 mm) 1/4" (6.4 mm) 1/4" (6.4 mm) 1/4" (6.4 mm) 1/4" (6.4 mm) 1/4" (6.4 mm) 3/8" (9.5 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 3/4" (19.1 mm) 9/64" (3.6 mm) 9/64" (3.6 mm) 13/64" (5.2 mm) 13/64" (5.2 mm) 13/64" (5.2 mm) 13/64" (5.2 mm) Ordering Information TankJet Tank Cleaning E 3/ L I I I I I Coverage Inlet Tube Capacity Size Size Material Code TankJet A Tank Cleaning E A I I I I I I Coverage Inlet Tube Ball Capacity Size Diameter Size 3A Designation 0211 Catalog

48 TankJet D41800E Fluid Driven Tank Cleaning s 12' (3.7 m) TankJet D41800E Fluid Driven Tank Cleaning s Compact, Constant-Speed s Provide Superior Cleaning Features and Benefits Features three flat sprays mounted in a rotating spray head driven by the flow of the cleaning liquid Rotates at nearly constant speed of 2 to 30 RPM over a wide range of fluid pressures up to four times higher impact than conventional rotating nozzles Perfect for cleaning, sanitizing and foaming applications; slow controlled rotational speed provides more dwell time on tank surface Compact fits in most tank openings as small as 1-1/4 (31 mm) Patented self-flushing water bearing design eliminates internal bearings or races All 316 stainless steel construction for maximum wear resistance; meets the European ATEX standard for use in explosive environments TankJet D41800E constant speed tank cleaning nozzles for tanks up to 12 (3.7 m) in dia. Sanitary pin connection conforms to 3A standards for CIP Sanitary pin version conforms to 3A sanitary standard for spray cleaning devices to remain in place Operates at high temperatures up to 300 F (150 C) Coverage 360 Specifications Max. tank dia.: 12 (3.7 m) Flow rate range: Pressure range: 2.7 to 33 gpm (12 to 128 l/min) 30 to 230 psi (2 to 16 bar) Ideal for Cleaning: Max. operating temperature: Min. tank opening size: coverage: 360 Inlet conn.: 300 F (150 C) 1-1/4 (31 mm) 3/8 NPT or BSPT, DN19 Chemical processing tanks Dry powder tanks Food processing tanks Mixing tanks Pharmaceutical tanks

49 12' (3.7 m) TankJet D41800E Fluid Driven Tank Cleaning s Performance Data Capacity Size 30 psi (2 bar) 40 psi (3 bar) Capacity gpm (l/min) 100 psi (5 bar) 150 psi (10 bar) 230 psi (16 bar) (10.8) 3.5 (14) 5.3 (17) 6.5 (24) 7.9 (30) (15.1) 4.8 (19) 7.5 (24) 9.1 (34) 11.3 (43) (33.2) 10.1 (40) 16.1 (52) 19.7 (73) 24 (93) (45.7) 14.0 (55) 22 (71) 27 (101) 34 (128) Dimensions and Weights D C Inlet Conn. A B Dia. C Dia. D Dia. Weight A D41800E 3/8" DN19 3" (78 mm) 3-7/32" (82 mm) 1-3/16" (30 mm) 1-3/16" (30 mm) 27/32" (21 mm) 27/32" (21 mm).094" (2.4 mm).28 lbs. (0.13 kg).29 lbs. (0.13 kg) Dimensions do not include connection pin length. B Ordering Information TankJet D41800E Tank Cleaning 3/8" Threaded Connection D41800E 3/8 316L* 9.9 I I I I Inlet Material Conn. Code Capacity Size TankJet D41800E Tank Cleaning DN19 Sanitary Connection D41800E L* 9.9 3A I I I I l Inlet Material Capacity Conn. Code Size 3A Version * Materials: Specify SS for Stainless Steel 303 (DIN1.4305). Specify 316L for Stainless Steel 316L (DIN1.4404). Add B prior to the inlet connection for BSPT connections Catalog 15 - D41800E

50 TankJet 19 Fluid Driven Tank Cleaner 12' (3.6 m) TankJet 19 Fluid Driven Tank Cleaner Slim and Sleek Design Ideal for Cleaning Tanks with Small Openings Features and Benefits Fits in tank openings as small as 2" (51 mm) with 7/8" (22 mm) probe for even smaller keg or drum bungholes Sleek design helps prevent residue buildup and simplifies maintenance Carefully drilled solid stream orifices are strategically placed to provide four different spray coverages Fluid driven unit rotates at a slow speed of 3 to 15 rpm for increased dwell time on tank surface compared to free spinning units Suitable for CIP or portable installations Mount vertically, horizontally or at any angle Made of 316 stainless steel and PTFE material TankJet 19 tank cleaner for tanks up to 12' (3.6 m) in dia. Specifications Coverage Flow rate range: 10 to 30 gpm (38 to 114 l/min) 180 Up 270 Down Pressure range: Rotation speed: 50 to 200 psi (3.4 to 13.8 bar) 3 to 15 RPM H D 180 Down 360 Max. operating temperature: Min. tank opening size: coverage: Inlet conn.: Weight: 250 F (121 C) 2.0" (51 mm) 360 ; 270 ; 180 up and down 3/4" NPT, BSPT (F) 2 lbs (0.9 kg) G C Ideal for Cleaning: Chemical mixers/blenders Drums and kegs Food processing tanks Pharmaceutical tanks Tablet coating machines

51 12' (3.6 m) TankJet 19 Fluid Driven Tank Cleaner Performance Data Model No. Coverage 50 psi (3.4 bar) 70 psi (4.8 bar) 90 psi (6.2 bar) 100 psi (6.9 bar) Capacity gpm (l/min) 120 psi (8.3 bar) 140 psi (9.7 bar) 160 psi (11 bar) 180 psi (12.4 bar) 200 psi (13.8 bar) H 10 (38) 13 (49) 15 (57) 16 (61) 18 (68) 19.5 (74) 21 (79) 22.5 (85) 24 (91) TJ-19 G 12 (45) 14 (53) 16.5 (62) 17.5 (66) 19 (72) 21 (79) 22.5 (85) 24 (91) 26 (98) D 16 (61) 18 (68) 20 (76) 21 (79) 22.5 (85) 24 (91) 26 (98) 27.5 (104) 28.5 (108) C 17 (64) 19 (72) 21 (79) 22 (83) 24 (91) 25.5 (97) 27.5 (104) 29 (110) 30 (114) Dimensions 1.97" (50 mm) 6.65" (169 mm) Ordering Information TankJet 19 Tank Cleaner TJ19 * C I I I Inlet Model No. *Add B for BSPT connections. If NPT connection, leave blank. Coverage 1112 Catalog 15 - TankJet 19

52 10' Solutions for Tanks Up to 10' (3 m) in Dia. (3 m) s Control Analysis Fabrication

53 TankJet 6353 & 6353-MFP Fixed Tank Cleaning s 10' (3 m) TankJet Fixed Tank Cleaning s 6353 & 6353-MFP Stationary Cluster s Provide Robust and Reliable Cleaning Features and Benefits Features 13 FullJet nozzles for high-capacity cleaning Simple, reliable and does not contain any moving parts TankJet 6353-MFP provides increased cleaning action by using 3/8 Maximum Free Passage (MFP) FullJet nozzles; MFP design helps reduce clogging Individual nozzles can be replaced with plugs to provide specific cleaning coverages s are easily removed for cleaning and inspection Can be installed in any position; special designs available for a wide range of coverages TankJet 6353 and 6353-MFP tank cleaning nozzles for tanks up to 10 (3 m) in dia. TankJet 6353 nozzle Uses 13 1/4 or 3/8 FullJet full cone nozzles Specifications Max. tank dia.: 10 (3 m) Flow rate range TankJet 6353: Flow rate range TankJet 6353-MFP: Pressure range: Max. operating temperature: Min. tank opening size: Materials TankJet 6353: Materials TankJet 6353-MFP: coverage: 360 Inlet conn.: 8.9 to 60 gpm (35 to 230 l/min) 25 to 80 gpm (93 to 301 l/min) 20 to 50 psi (1.5 to 3.5 bar) 212 F (100 C) 6 (152 mm) Brass, 303 or 316 stainless steel Brass or 316 stainless steel 1-1/2 NPT or BSPT (F) TankJet 6353-MFP nozzle Uses 13 3/8 FullJet full cone nozzles Coverage 360 Ideal for Cleaning: Chemical processing tanks Process tanks Pulp chests

54 10' (3 m) TankJet 6353 & 6353-MFP Fixed Tank Cleaning s Performance Data No. FullJet No. Max. Free Pass in. (mm) 20 psi (1.5 bar) 30 psi (2 bar) Capacity gpm (l/min) 40 psi (3 bar) 50 psi (3.5 bar) /4 GG (1.3) 8.9 (35) 10.8 (40) 12.3 (48) 13.6 (52) /4 GG (1.6) 17.9 (70) 22 (80) 25 (97) 27 (104) /8 GG (2.8) 39 (155) 48 (177) 55 (215) 60 (230) /8 HHMFP (3.2) 25 (93) 29 (108) 31 (118) 33 (123) /8 HHMFP (4.0) 38 (143) 44 (167) 49 (187) 54 (204) /8 HHMFP (4.8) 55 (206) 65 (246) 73 (276) 80 (301) Dimensions and Weights A A B B TankJet 6353 No. A B Dia. Weight TankJet 6353-MFP No. A B Dia. Weight /4GG5 4-1/2" (114 mm) 4-1/2" (114 mm) 3.7 lbs. (1.6 kg) /8HHMFP /2" (114 mm) 4-1/2" (114 mm) 3.7 lbs. (1.6 kg) /4GG10 4-1/2" (114 mm) 4-1/2" (114 mm) 3.7 lbs. (1.6 kg) /8HHMFP /2" (114 mm) 4-1/2" (114 mm) 3.7 lbs. (1.6 kg) /8GG22 4-3/4" (121 mm) 5" (127 mm) 4.5 lbs. (2.0 kg) /8HHMFP /2 (114 mm) 4-1/2" (114 mm) 3.7 lbs. (1.6 kg) Ordering Information TankJet 6353 Tank Cleaning /4GG 316SS 5 I I I I Material Code No. Capacity Size TankJet 6353-MFP Tank Cleaning /8HHMFP 316SS 14 I I I I Material Code No. Capacity Size Add B prior to the inlet connection for BSPT connections Catalog

55 TankJet AA090 Motor Driven Tank Cleaner 8' (2.4 m) TankJet AA090 Motor Driven Tank Cleaner Provides High-Impact Cleaning and Trouble-Free Installation Features and Benefits Versatile high-impact tank cleaner provides efficient, consistent, reliable cleaning with virtually no maintenance Customize for your cleaning operation. Choose: Air (AG), electric (E) or explosion-proof (EP) electric motor capacity size 1.5, 3, 4 or 6 (.5,.9, 1.2 or 1.8 m) shaft length Optional adjustable flange for precise positioning of turret in tank Solid stream spray nozzles rotate in multiple axes and provide thorough cleaning and complete coverage of the entire tank TankJet AA090AG tank cleaner for tanks up to 8 (2.4 m) in dia. Motor is positioned outside the tank away from harmful caustics Lightweight can be installed permanently or easily moved from tank to tank Long wear life materials of construction corrosion-resistant 316 stainless steel and PTFE fluoropolymer resin seals Specifications Max. tank dia.: 8 (2.4 m) Flow rate range: 1.5 to 7.3 gpm (5.7 to 28 l/min) Coverage Lubricator assembly is included with the air (AG) model only. Regular lubrication of the air supply line will significantly increase the life of the air motor. Pressure range: Max. operating temperature: Min. tank opening size: 100 to 500 psi (7 to 35 bar) 200 F (93 C) 2.3 (59 mm) 360 coverage: 360 Inlet conn.: 1 NPT or BSPT (F) Ideal for Cleaning: Drums Motor: Air, electric, explosion-proof electric Process tanks Shaft lengths: 1.5, 3, 4 or 6 (.5,.9, 1.2 or 1.8 m) Totes

56 8' (2.4 m) TankJet AA090 Motor Driven Tank Cleaner Performance Data No. Total Flow of Two s (Equal Capacity) gpm or l/min Liquid Inlet Pressure* 100 psi (7 bar) 200 psi (15 bar) 300 psi (20 bar) 400 psi (30 bar) 500 psi (35 bar) W (5.7) 2.0 (7.6) 2.4 (9.1) 2.8 (10.6) 3.2 (12.1) W (10.2) 3.7 (14.0) 4.5 (17.0) 5.1 (19.3) 5.8 (22.0) W (13.2) 4.7 (17.8) 5.8 (22.0) 6.6 (25.0) 7.3 (28.0) *Note: Flow rates tabulated above include pressure drop through unit. Cycle Time Data Air Motor (AG) Air Pressure psi (bar) Air Consumption scfm (l/min) Approx. Speed (rpm) Approx. Time for One Complete Cycle (min.) 5 (0.34) 1.4 (40) (0.48) 2.0 (57) (0.68) 3.1 (88) Dimensions and Weights Air Motor (AG) Model No. Extension Length Overall Length Weight AA090AG ' (0.5 m) 35" (0.8 m) 12-1/2 lbs. (5.7 kg) AA090AG-3 3' (0.9 m) 53" (1.3 m) 14 lbs. (6.4 kg) AA090AG-4 4' (1.2 m) 65" (1.6 m) 15-1/2 lbs. (7 kg) AA090AG-6 6' (1.8 m) 89" (2.2 m) 18-1/2 lbs. (8.4 kg) Cycle Time Data Electric Motor (E and EP) Motor Electric Explosion- Proof Model No. AC Frequency Speed (rpm) Current (amps) Power (watts) Approx. Time for One Complete Cycle (min.) 50 Hz Hz Hz Hz Dimensions and Weights Electric Motor (E) Extension Length Overall Length Weight AA090E ' (0.5 m) 29-5/8" (0.7 m) 12-1/2 lbs. (5.7 kg) AA090E-3 3' (0.9 m) 47-5/8" (1.2 m) 14 lbs. (6.4 kg) AA090E-4 4' (1.2 m) 59-5/8" (1.5 m) 15-1/2 lbs. (7 kg) AA090E-6 6' (1.8 m) 83-5/8" (2.1 m) 18-1/2 lbs. (8.4 kg) Dimensions and Weights Explosion-Proof Motor (EP) Model No. Extension Length Overall Length Weight AA090E-EP ' (0.5 m) 32-5/8" (0.8 m) 20 lbs. (9.1 kg) AA090E-EP-3 3' (0.9 m) 50-5/8" (1.3 m) 22 lbs. (10 kg) AA090E-EP-4 4' (1.2 m) 62-5/8" (1.6 m) 23 lbs. (10.5 kg) AA090E-EP-6 6' (1.8 m) 86-5/8" (2.2 m) 26 lbs. (11.8 kg) Head Tank Diameter Opening 2.3" (59 mm) Opening Ordering Information 1.1" (29 mm).84" (22 mm) TankJet AA090 Tank Cleaner Tank Cleaner No. AA090E 3 + W 0005 I I I I Tank Cleaner Extension Length Capacity Size Add B after AA in the tank cleaner type and prior to nozzle inlet connection for BSPT connections " (3 mm) 2.0" (51 mm).73" (18 mm) Catalog 15 - AA090

57 TankJet 18250A Fluid Driven Tank Cleaning 8' (2.4 m) TankJet 18250A Fluid Driven Tank Cleaning Rotating Provides Complete Orbital Coverage Features and Benefits Features three flat sprays mounted in a rotating spray head driven by the flow of the cleaning liquid Precisely positioned orifices provide complete coverage of all interior surfaces Can be installed horizontally or vertically Constructed for long wear life using corrosion-resistant materials 316 stainless steel with Ryton (polyphenylene sulfide and kolsterized stainless steel) bearing retainers and sleeves of 50% stainless steel PTFE Optimize cleaning performance by using single-pass or particulate-free cleaning liquid Can withstand temperatures up to 350 F (177 C) TankJet 18250A tank cleaning nozzle for tanks up to 8 (2.4 m) in dia. Specifications Max. tank dia. 8 (2.4 m) Coverage 360 Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: 10.5 to 55 gpm (48 to 205 l/min) 10 to 60 psi (1 to 4 bar) 350 F (177 C) 2-7/32 (60 mm) Ideal for Cleaning: coverage: 360 Inlet conn.: 3/4 NPT or BSPT (F) Ryton is a registered trademark of Chevron Phillips Chemical Company LLC. Barrels Chemical tanks Food vats Processing vessels

58 8' (2.4 m) TankJet 18250A Fluid Driven Tank Cleaning Performance Data No. 10 psi (1 bar) 20 psi (1.5 bar) Capacity gpm (l/min) 30 psi (2 bar) 40 psi (2.5 bar) 50 psi (3 bar) 60 psi (4 bar) 18250A-316SS21-316SS 10.5 (48) 14.8 (59) 18.2 (68) 21 (76) 23 (83) 26 (96) 18250A-316SS45-316SS 23 (103) 32 (126) 39 (145) 45 (162) 50 (178) 55 (205) Dimensions and Weights Hex. No. A B C Hex. Weight 18250A 5-29/64" (138.4 mm) 4-35/64" (115.5 mm) 2-6/13" (53.6 mm) 1-5/8" (34.9 mm) 1.6 lbs. (0.73 kg) B A C Ordering Information TankJet 18250A Tank Cleaning 18250A 316SS SS I I I I Bearings Capacity and Races Size Material Code Add B prior to the nozzle type connection for BSPT connections. Material Code 0211 Catalog A

59 TankJet Fluid Driven Tank Cleaning 8' (2.4 m) TankJet Fluid Driven Tank Cleaning Rotating Miniature PTFE s Rinse Small Containers Features and Benefits The reactionary force of cleaning liquid rotates the nozzle no motor required Features a rotating spray head that can be easily removed from the body for inspection and maintenance Long wear life PTFE resists aggressive cleaning liquids Fits into tank openings as small as 1 (25 mm) Lightweight weighs only 0.5 oz. (0.02 kg) Specifications Max. tank dia.: 8 (2.4 m) Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet conn.: Performance Data No. 10 psi (0.7 bar) 2.1 to 4.5 gpm (7.8 to 18 l/min) 10 to 50 psi (0.7 to 4 bar) 200 F (93 C) 1 (25 mm) Approx. 360, 180 up, 180 down 1/4 NPT or BSPT (M) 20 psi (1.5 bar) Capacity gpm (l/min) 30 psi (2 bar) 40 psi (3 bar) 50 psi (4 bar) /4-TEF 2.1 (7.8) 2.9 (11.3) 3.5 (13) 4.0 (15) 4.5 (18) Ideal for Cleaning: Chemical containers Cylinders Ducts Pipes Coverage A TankJet tank cleaning nozzle for tanks up to 8 (2.4 m) in dia. 180 Up 180 Down 360 Dimensions and Weights A B E Ordering Information TankJet Tank Cleaning E 1/4 TEF I I I I Coverage Inlet Conn. Add B prior to the inlet connection for BSPT connections Material Code No. A B Dia. Weight /4" (44.4 mm) B Dia. 7/8" (22.3 mm) 0.5 oz. (0.02 kg) Catalog

60 TankJet D41892 Fluid Driven Tank Cleaning 6.5' (2 m) TankJet D41892 Fluid Driven Tank Cleaning Lightweight Plastic s Provide Effective Rinsing Features and Benefits Features three flat sprays mounted in a rotating spray head driven by the flow of the cleaning liquid 360 spray coverage rinses entire tank nozzle and flat spray inserts constructed of POM and PVDF for durability and corrosion resistance Lightweight weighs just 1.4 oz. (0.04 kg) CIP connection and ATEX-certified versions available upon request Specifications Max. tank dia.: 6.5 (2.0 m) Flow rate range: Pressure range: 4.0 to 7.5 gpm (15.9 to 29 l/min) 20 to 70 psi (1.5 to 5 bar) Max. operating temperature: 160 F (70 C) Min. tank opening size: 1-1/2 (37 mm) coverage: 360 Inlet conn.: Performance Data No. D41892-POM-6 20 psi (1.5 bar) 4.0 (15.9) 3/8, 1/2 NPT or BSPT (F) 30 psi (2 bar) 4.9 (18.3) Capacity gpm (l/min) 40 psi (2.5 bar) 5.7 (20.5) 50 psi (3 bar) 6.4 (22.5) Note: Recommended operating pressure is 30 to 60 psi (2 to 4 bar). 60 psi (4 bar) 7.0 (26) 70 psi (5 bar) 7.5 (29) TankJet D41892 tank cleaning nozzle for tanks up to 6.5 (2 m) in dia. Coverage 360 Dimensions and Weights A B Ideal for Cleaning: Chemical containers Food containers Mixing tanks Ordering Information TankJet D41892 Tank Cleaning D /2 POM 6 I I I I Inlet Material Conn. Code Add B prior to the inlet connection for BSPT connections Capacity Size No. A B Weight D " (68 mm) 1.46" (37 mm) 1.4 oz. (0.04 kg) Catalog 15 - D41892

61 TankJet D41990 Micro Tank Cleaning 6.5' (2 m) TankJet D41990 Micro Tank Cleaning Rotating Provides Complete Coverage Features and Benefits Low pressure, low volume rinsing of small tanks and containers up to 6.5 (2 m) Fluid driven reactionary force nozzle no motor source needed to drive spray head Micro-size nozzle fits into very small tank openings as small as 1 (25 mm) All 316L stainless steel construction for long wear life and corrosion resistance Suitable for high temperature applications up to 300 F (149 C) Can be installed vertically or horizontally TankJet D41990 micro tank cleaning nozzle for tanks up to 6.5 (2 m) in dia. Specifications Max. tank dia. 6.5 ft (2.0 m) Coverage 180 Up 180 Down 360 Flow rate range: 2.5 to 7.3 gpm (9.5 to 28 l/min) Pressure range: 15 to 60 psi (1 to 4 bar) A B E Max. operating temperature: 300 F (149 C) Min. tank opening size: 1 (25 mm) thread 2 (50 mm) CIP version Ideal for Cleaning: coverage: 180 up, 180 down, 360 Inlet conn.: 3/8 NPT or BSPT, CIP 182 Weight: 1.9 oz. (54 g) Chemical tanks Beverage tanks Canisters Food tanks Keg/drum Tote/container

62 6.5' (2 m) TankJet D41990 Micro Tank Cleaning Performance Data Capacity Size 15 psi (1 bar) 20 psi (1.5 bar) Capacity gpm (l/min) 30 psi (2 bar) 40 psi (2.5 bar) 50 psi (3 bar) 60 psi (4 bar) (9.4) 2.7 (10.5) 3.1 (11.5) 3.4 (12.4) 3.6 (13.2) 3.9 (14.7) (12.7) 3.7 (14.4) 4.3 (15.9) 4.7 (17.3) 5.1 (18.5) 5.5 (20.7) (16.9) 4.9 (19.2) 5.7 (21) 6.3 (23) 6.8 (25) 7.3 (28) Dimensions C No. Inlet Connection A B C D /8 CIP (18 mm) 0.7 (18 mm) 2.4 (60 mm) 2.5 (63 mm) 0.79 (20 mm) 0.84 (21.2 mm) B A Ordering Information D41990 Tank Cleaning D41990 E 3/8 316L 3.2 I I I I I Coverage Connection Material Size Code Add B prior to inlet connection for BSPT connections. Capacity Size 0211 Catalog 15 - D41990

63 5' Solutions for Tanks Up to 5' (1.5 m) in Dia. (1.5 m) s Control Analysis Fabrication

64 TankJet 21400A Fluid Driven Tank Cleaning 5' (1.5 m) TankJet 21400A Fluid Driven Tank Cleaning Compact Rotating Provides Complete Coverage Features and Benefits Features three flat sprays mounted in a rotating spray head driven by the flow of the cleaning liquid Precisely positioned orifices provide complete orbital coverage of all interior surfaces Can be installed vertically or horizontally Constructed for long wear life using corrosion-resistant materials 316 stainless steel with Ryton (polyphenylene sulfide) and kolsterized 316 stainless steel bearing retainers; sleeves of 50% stainless steel PTFE Optimize cleaning performance by using single-pass or particulate-free cleaning liquid Can withstand temperatures up to 350 F (177 C) Specifications Max. tank dia. 5 (1.5 m) Coverage 360 TankJet 21400A tank cleaning nozzle for tanks up to 5 (1.5 m) in dia. Flow rate range: Pressure range: Max. operating temperature: 5.0 to 22 gpm (23 to 82 l/min) 10 to 60 psi (1 to 4 bar) 350 F (177 C) Min. tank opening size: coverage: 360 Inlet conn.: 2-1/4 (60 mm) 3/4 NPT or BSPT (F) Ryton is a registered trademark of Chevron Phillips Chemical Company LLC. Ideal for Cleaning: Barrels Chemical tanks Food vats Processing vessels

65 5' (1.5 m) TankJet 21400A Fluid Driven Tank Cleaning Performance Data No. 10 psi (1 bar) 20 psi (1.5 bar) Capacity gpm (l/min) 30 psi (2 bar) 40 psi (2.5 bar) 50 psi (3 bar) 60 psi (4 bar) 21400A-316SS10-316SS 5.0 (23) 7.1 (28) 8.7 (32) 10 (36) 11.2 (39) 12.2 (46) 21400A-316SS18-316SS 9.0 (41) 12.7 (50) 15.6 (58) 18 (65) 20 (71) 22 (82) Dimensions and Weights C Hex. No. A B C Hex. Weight 21400A 5-9/32" (134 mm) 4-25/64" (111.5 mm) 1-3/4" (44.5 mm) 1-5/8" (34.9 mm) 1.5 lbs. (0.68 kg) B A Ordering Information TankJet 21400A Tank Cleaning 21400A 316SS SS I I I I Bearings Capacity and Races Size Material Code Add B prior to the nozzle type for BSPT connections. Material Code 0211 Catalog A

66 TankJet VSM Fixed Tank Cleaning 5' (1.5 m) TankJet VSM Fixed Tank Cleaning Lightweight Balls Ideal for Low Pressure Rinsing Features and Benefits Stationary nozzles ideal for rinsing small vessels Suitable for CIP no moving parts 240 spray coverage via 40 spray orifices Can be installed in any position Economical, effective rinsing Nylon construction provides excellent chemical resistance TankJet VSM tank cleaning nozzle for tanks up to 5 (1.5 m) in dia. Specifications Max. tank dia.: 5' (1.5 m) Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: 2.7 to 72 gpm (10.4 to 269 l/min) 10 to 150 psi (.7 to 10 bar) 200 F (93 C) 2" (51 mm) Coverage 240 Down coverage: 240 Material: Nylon Inlet conn.: 1/2" or 3/4" NPT or BSPT (F) Ideal for Cleaning: Chemical containers Pharmaceutical vats

67 5' (1.5 m) TankJet VSM Fixed Tank Cleaning Performance Data No. Max. Free Pass in. (mm) 10 psi (0.7 bar) 20 psi (1.5 bar) 40 psi (3 bar) Capacity gpm (l/min) 60 psi (4 bar) 80 psi (5 bar) 100 psi (7 bar) 130 psi (9 bar) 150 psi (10 bar) VSM-1/ (0.8) 2.7 (10.4) 3.9 (15.3) 5.5 (22) 6.7 (25) 7.8 (28) 8.7 (33) 9.9 (38) 10.6 (40) VSM-1/ (1.0) 4.3 (16.3) 6.1 (24) 8.6 (34) 10.6 (39) 12.2 (44) 13.7 (52) 15.6 (59) 16.7 (62) VSM-1/ (1.5) 8.8 (33) 12.5 (49) 17.7 (70) 22 (81) 25 (90) 28 (107) 32 (121) 34 (127) VSM-3/ (1.5) 8.8 (33) 12.5 (49) 17.7 (70) 22 (81) 25 (90) 28 (107) 32 (121) 34 (127) VSM-1/ (1.95) 13.7 (52) 19.4 (77) 28 (108) 34 (125) 39 (140) 43 (166) 50 (188) 53 (198) VSM-3/ (1.95) 13.7 (52) 19.4 (77) 28 (108) 34 (125) 39 (140) 43 (166) 50 (188) 53 (198) VSM-1/ (2.3) 18.6 (71) 26 (104) 37 (147) 46 (170) 53 (190) 59 (225) 67 (254) 72 (269) VSM-3/ (2.3) 18.6 (71) 26 (104) 37 (147) 46 (170) 53 (190) 59 (225) 67 (254) 72 (269) Dimensions and Weights A No. Inlet Conn. NPT or BSPT A Dia. B C Weight B C VSM 1/2" F 3/4" F 1-1/4" (31.2 mm) 1-7/8" (47 mm) 1-11/16" (45 mm) 2-7/16" (62 mm) 1" (26 mm) 1-1/2" (40 mm) 3 oz. (0.08 kg) 8 oz. (0.225 kg) Ordering Information TankJet VSM Tank Cleaning VSM 3/4 140 I I I Inlet Conn. Add B prior to the nozzle type for BSPT connections. Capacity Size 0211 Catalog 15 - VSM

68 TANKJET M60 MOBILE TANK CLEANER 5' (1.5 m) TankJet M60 MOBILE TANK CLEANER Fast and Powerful Cleaning of Barrels, Drums and Other Vessels Features and Benefits Powerful cleaning using low flow rates Removes tough residues quickly and effectively; solid stream sprays rotate in multiple axes for complete and thorough coverage Mobile - can easily be moved from one barrel or drum to the next Fast cycle time; less than 5 minutes. One full cycle completed every 16 revolutions Compact fits in openings as small as 1-3/4" (44.5 mm) and easily inserted into standard bung hole openings Compatible with a variety of pumps including pressure washers Material construction in contact with fluid stainless steel, carbon graphite PTFE filled PEEK, EPDM, and PTFE Non-lubricated air motor driven for continuous and reliable operation Easy to operate and rebuild TankJet M60 tank cleaner for tanks up to 5 (1.5 m) in dia. Specifications Max. tank dia.: 5' (1.5 m) Coverage 360 Flow rate range: Cycle time: Max. operating liquid pressure: Max. liquid temp.: Min. tank opening: Weight: Liquid conn.: Air line conn.: 1.1 to 10 gpm (4.2 to 38 l/min) Under 5 min psi (69 bar) 180 F (82 C) 1.75" dia. (44.5 mm) 26 lbs. (11.8 kg) 3/8" NPT or BSPT (F) 1/4" NPT or BSPT (F) Ideal for Cleaning: Wine barrels Food and beverage barrels Chemical and storage barrels Drums and kegs Small tanks and containers

69 5' (1.5 m) TANKJET M60 MOBILE TANK CLEANER Performance Data Capacity gpm (l/min) Model No. 100 psi (7 bar) 200 psi (15 bar) 300 psi (20 bar) 400 psi (30 bar) 500 psi (35 bar) 700 psi (50 bar) 1000 psi (70 bar) TJM60AG (4.2) 1.6 (6.1) 1.9 (7.1) 2.2 (8.7) 2.5 (9.4) 2.9 (11.2) 3.5 (13.3) TJM60AG (6.0) 2.3 (8.8) 2.8 (10.2) 3.2 (12.5) 3.6 (13.4) 4.2 (16.1) 5.0 (19.0) TJM60AG (7.2) 2.7 (10.5) 3.3 (12.1) 3.8 (14.8) 4.2 (16.0) 5.0 (19.1) 6.0 (22.6) TJM60AG (8.7) 3.2 (12.7) 4.0 (14.6) 4.6 (17.9) 5.1 (19.4) 6.1 (23.1) 7.2 (27.4) TJM60AG (12.1) 4.5 (17.7) 5.5 (20.4) 6.4 (25.0) 7.2 (27.0) 8.5 (32.3) 10.1 (38.3) Cycle Time Data Non-Lubricated Air Motor Air Pressure psi (bar) Air Consumption scfm (l/min) Approx. Speed (rpm) 1000 psi/180 F (70 bar/82 C) Approx. Time for One Complete Cycle (min.) 10 (.7) 3.9 (108) (.85) 4.7 (136) (1) 5.9 (162) (1.4) 7.8 (224) *Cycle time refers to the time it takes to complete one full cycle. One full cycle is completed every 16 revolutions. Dimensions and Weights A Ordering Information TankJet M60 Tank Cleaner B TJM60AG 055 I Model No. I Orifice Size Add B for BSPT connections after the model no. C D F E G A B C D E F G Weight 35.0" (89.1 cm) 21.4" (54.3 cm) 29.0" (74.2 cm) 25.5" (64.7 cm) 7.0" (17.7 cm) 10.4" (26.5 cm) 9.25" (23.5 cm) 26 lbs. (11.8 kg) O615 Catalog 15 - TankJet M60

70 TankJet Fluid Driven Tank Cleaning 3' (0.9 m) TankJet Fluid Driven Tank Cleaning Compact, Rotating s Provide Efficient Rinsing of Barrels and Kegs Features and Benefits Choose from two designs: has two flat sprays that produce the self-rotating force and side sprays adds a third spray via a top orifice to provide nearly full spherical spray coverage Long wear life nozzle is constructed of 316 stainless steel with bearings and races made of specially-hardened 316 stainless steel Standard internal 50% stainless steel filled PTFE sleeve or optional PTFE sleeve Can withstand temperatures up to 350 F (177 C) TankJet tank cleaning nozzle for tanks up to 3 (0.9 m) in dia. Specifications Max. tank dia.: 3 (.9 m) Coverage 360 Side Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: spray coverage: spray coverage: Inlet conn.: 3.5 to 22 gpm (14 to 79 l/min) 20 to 200 psi (1.5 to 12 bar) 350 F (177 C) 1-1/32 (26 mm) side sprays 360 1/2 NPT or BSPT (F) Ideal for Cleaning: Barrels Cylinders Ducts Kegs Pipes Tubes

71 3' (0.9 m) TankJet Fluid Driven Tank Cleaning Performance Data No. 20 psi (1.5 bar) 40 psi (3 bar) 60 psi (4 bar) Capacity gpm (l/min) 80 psi (5 bar) 100 psi (6 bar) 120 psi (8 bar) 150 psi (10 bar) 200 psi (12 bar) SS-5-316SS 3.5 (14) 5.0 (19.7) 6.1 (23) 7.1 (25) 7.9 (28) 8.7 (32) 9.7 (36) 11.2 (39) SS-8-316SS 5.7 (22) 8.0 (32) 9.8 (36) 11.3 (41) 12.6 (45) 13.9 (52) 15.5 (58) 17.9 (63) SS SS 4.0 (15.9) 5.7 (22) 7.0 (26) 8.1 (29) 9.0 (32) 9.9 (37) 11.0 (41) 12.7 (45) SS-7-316SS 4.9 (19.5) 7.0 (28) 8.6 (32) 9.9 (36) 11.1 (39) 12.1 (45) 13.6 (50) 15.7 (55) SS SS 7.1 (28) 10.0 (39) 12.2 (46) 14.1 (51) 15.8 (56) 17.3 (64) 19.4 (72) 22 (79) Dimensions and Weights No. A B Dia. Weight /2" (89 mm) 1" (25.4 mm) 8 oz. (0.23 kg) A B Ordering Information TankJet Tank Cleaning SS 5 316SS I I I I I Coverage Capacity Size Bearings and Races Material Code Add B prior to the nozzle type for BSPT connections. Material Code 0211 Catalog

72 TankJet 3150 Fixed Tank Cleaning 3' (0.9 m) TankJet 3150 Fixed Tank Cleaning Stationary, Self-Draining Ideal for Barrel Rinsing Features and Benefits Stationary design no moving parts Choose 21 orifices for 360 coverage or 15 orifices for 210 coverage Can be installed in any position Durable, corrosion-resistant design 3/4 (19 mm) neck allows drainage during washing #3 full cone tips and vanes For (Qty. 20) For (Qty. 14) the bottom ring of full cone tips is eliminated 1/4 G10 cap and vane (Qty. 1) TankJet 3150 tank cleaning nozzle for tanks up to 3 (0.9 m) in dia. Specifications Max. tank dia.: 3 (0.9 m) Coverage Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Materials: Inlet conn.: 5.2 to 26 gpm (23 to 91 l/min) 10 to 150 psi (1 to 10 bar) 212 F (100 C) 2 (51 mm) 21 orifice version for 360 coverage 15 orifice version for 210 coverage Brass, 303 stainless steel, mild steel, 316 stainless steel 1 NPT or BSPT (M) Ideal for Cleaning: Barrels Containers Drums Kegs Tubes Vessels

73 3' (0.9 m) TankJet 3150 Fixed Tank Cleaning Performance Data No. Max. Free Passage in. (mm) 10 psi (1 bar) 20 psi (2 bar) 30 psi (3 bar) Capacity gpm (l/min) 40 psi (4 bar) 60 psi (5 bar) 80 psi (6 bar) 100 psi (7 bar) 150 psi (10 bar) (1.0) 5.2 (23) 7.2 (32) 8.7 (39) 9.9 (44) 12.1 (49) 13.8 (54) 15.3 (57) 19.0 (67) (1.0) 7.0 (31) 9.8 (43) 11.7 (52) 13.3 (59) 16.2 (66) 18.5 (73) 21 (77) 26 (91) Dimensions and Weights No A Dia. B C Dia. Weight 1-11/16" (43 mm) 6-9/16" (167 mm) 3/4" (19 mm) 1-1/2 lbs. (0.68 kg) C B A Ordering Information TankJet 3150 Tank Cleaning 3150 SS 15 I I I Material Code Add B prior to the nozzle type for BSPT connections. Number of Full Cone Tips 0211 Catalog

74 TankJet Fluid Driven Tank Cleaning 3' (0.9 m) TankJet Fluid Driven Tank Cleaning Compact, Rotating s Provide Cylindrical Coverage Features and Benefits Two flat sprays produce the self-rotating force to drive the nozzle and provide side sprays for cylindrical coverage Can be mounted in any position Long wear life nozzles are available in stainless steel and hardened stainless steel bearings and races Choice of brass, mild steel and 303 or 316 stainless steel TankJet tank cleaning nozzle for tanks up to 3 (0.9 m) in dia. Specifications Max. tank dia.: 3 (0.9 m) Coverage Side s Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet conn.:.8 to 2.2 gpm (3.4 to 7.9 l/min) 10 to 60 psi (1 to 4 bar) 200 F (93 C) 1-1/32 (26 mm) Side sprays 1/4 NPT or BSPT (F) Ideal for Cleaning: Cylinders Ducts Pipes

75 3' (0.9 m) TankJet Fluid Driven Tank Cleaning Performance Data No. 10 psi (1 bar) 20 psi (1.5 bar) 30 psi (2 bar) Capacity gpm (l/min) 40 psi (2.5 bar) 50 psi (3 bar) 60 psi (4 bar) SS 0.8 (3.4) 1.2 (4.9) 1.5 (5.3) 1.7 (6.1) 1.9 (6.8) 2.2 (7.9) Dimensions and Weights Hex. No. A B Dia. C Hex. Weight /8" (47.6 mm) 1" (25.4 mm) 1-9/16" (39.7 mm) 7/8" (22.2 mm) 3 oz. (0.09 kg) A C B Ordering Information TankJet Tank Cleaning SS I I I Capacity Size Add B prior to the nozzle type for BSPT connections. Material Code 0211 Catalog

76 TankJet Fixed Tank Cleaning 2' (0.6 m) TankJet Fixed Tank Cleaning Stationary, Self-Draining Ideal for Keg Rinsing Features and Benefits Stationary design no moving parts Choose 21 orifices for 360 coverage or 15 orifices for 210 coverage Reduced neck allows drainage during cleaning Can be installed in any position Durable, corrosion-resistant design; choice of 303 or 316 stainless steel #3-SS full cone tip and vane (Qty. 1) TankJet tank cleaning nozzle for tanks up to 2 (0.6 m) in dia. #1.5-SS full cone tips and #1-SS vanes For SS (Qty. 20) For SS (Qty. 14) the bottom ring of full cone tips is eliminated Specifications Max. tank dia.: 2 (.6 m) Coverage Flow rate range: Pressure range: Max. operating temperature: Min. tank opening size: coverage: Inlet conn.: 5.5 to 11.7 gpm (23 to 43 l/min) 60 to 150 psi (5 to 10 bar) 212 F (100 C) 2 (51 mm) 21 orifice version for 360 coverage 15 orifice version for 210 coverage 1 NPT or BSPT (M) Ideal for Cleaning: Containers Drums Kegs Pipes Tubes

77 2' (0.6 m) TankJet Fixed Tank Cleaning Performance Data No. Max. Free Passage in. (mm) 60 psi (5 bar) 80 psi (6 bar) Capacity gpm (l/min) 100 psi (7 bar) 150 psi (10 bar) SS (2.4) 5.5 (23) 6.3 (25) 7.0 (26) 8.5 (31) SS (2.4) 7.7 (31) 8.7 (34) 9.6 (36) 11.7 (43) Dimensions and Weights No A Dia. B C Dia. Weight 1-3/8" (35 mm) 6-1/8" (156 mm) 5/8" (16 mm) 1-1/8 lbs. (0.51 kg) C B A Ordering Information TankJet Tank Cleaning SS I I I Number of Full Cone Tips Add B prior to the nozzle type for BSPT connections. Material Code 0211 Catalog

78 Additional Products & Accessories Additional Products & Accessories s Control Analysis Fabrication

79 Strainers for TankJet Products Additional Products & Accessories Strainers for TankJet Products Ensure Trouble-Free Performance Features and Benefits Reduce clogging in tank cleaners and tank cleaning nozzles Remove contaminants from liquid to ensure continuous movement of rotating spray heads Extend wear life of nozzles, valves and pumps Wide range of options: heavy duty, heavy duty high pressure, self cleaning and a wide range of mesh sizes Model TW: Large open screen area for efficient liquid straining Designed for minimal maintenance Removable bottom cap or plug for complete withdrawal of entire screen assembly Bottom pipe plug can be replaced with a drain cock for quick-flush cleaning Model TWC same features as TW plus: Handles large flow rates with minimal pressure drop 1 plugged top outlet is provided for pressure gauge installation Model 8310A: Designed for high pressure operation Removable bottom pipe plug provides an easy method for flush cleaning Self-Cleaning Strainers for high flow applications: Allows use of poor quality water with minimal risk of nozzle clogging Choice of models and styles flow rates up to 1760 gpm (6662 l/min) Large filter area captures most debris extending time between flush cycles Minimal water used for flushing downstream water supply is not interrupted Easy to use and maintain Model TW Strainer Model TW Strainer Self-Cleaning Strainer

80 Additional Products & Accessories Strainers for TankJet Products Strainer Compatibility Chart Part No. Description 1/2TW Heavy Duty Strainer 1TW Heavy Duty Strainer 1-1/2TW Heavy Duty Strainer 2-1/2TW Heavy Duty Strainer 3TWC Heavy Duty Strainer 8310A-1/2 Heavy Duty Strainer TankJet 360 Tank Cleaner l TankJet 180 Tank Cleaner l TankJet AA290 Tank Cleaner l l TankJet 80 Tank Cleaner TankJet 65 Tank Cleaner l l TankJet AA190 Tank Cleaner l l TankJet 75 Tank Cleaner l TankJet 27500/28500 s l l l TankJet l l l l TankJet D26984/ D40159 s l l TankJet D41800E l l TankJet 6353 l l TankJet AA090 Tank Cleaner l l TankJet 18250A l l TankJet D41892 l l TankJet D41990 l TankJet 21400A l l TankJet 15498/3150 s l l TankJet l TankJet l l Installation Suction or Pressure Side of Pump up to 130 psi (9 bar) Pressure Side Max. flow rate with.035 bar pressure drop 11 gpm (42 l/min) 31.4 gpm (119 l/min) 71.6 gpm (271 l/min) gpm (517 l/min) 21.1 gpm (80 l/min) with 36.2 psi (2.5 bar) pressure Ask your local sales engineer for more information about our self-cleaning strainers. Mesh Recommendations Motor Driven Tank Cleaner Mesh Recommendation 100 min. Fluid Driven (Turbine) 30 to 50 Fluid Driven (Reactionary Force and Constant Speed) Fixed Stationary 200 min. Refer to Mesh to Micron Conversion Chart Mesh to Micron Conversion Chart Mesh Micron Inches (mm) (1.2) (.84) (.58) (.29) (.24) (.17) (.14) (.08) 0211 Catalog 15 - Strainers

81 Tank Cleaning Lances Additional Products & Accessories Tank Cleaning Lances Ensure Efficient Fluid Delivery to Tank Cleaning s Features and Benefits Specify to your requirements: type of tank cleaning nozzle, pipe length, flange type/connections, material Working with a single supplier ensures optimal performance and offers convenience Tank cleaning lance with unique constant speed TankJet D40159 for cleaning and rinsing Tank cleaning lance with TankJet 6353 nozzle for gentle rinsing Specifications TankJet tank cleaning nozzle: Select any TankJet nozzle or spray ball Connections: Select NPT or BSPT connections, cam lock connections, raised face flanges or tri-clamp fittings Pipe/tube size and length: Materials of construction: Specify Specify material for each component stainless steel, PTFE, PVDF, brass, polypropylene Tank cleaning lance with TankJet spray ball can be installed in any direction for 180 or 360 spray coverage in tanks up to 13 (4 m) dia Catalog 15 - Tank Cleaning Lances

82 Retractable Tank Washer (RTW) Additional Products & Accessories Retractable Tank Washer (RTW) Automates Tank Cleaner Insertion and Retraction from Tank Features and Benefits Pneumatic retraction mechanism lowers and raises the tank cleaner from the tank eliminating the need for manual labor Eliminates clogging resulting from residue build-up on nozzle hub when tank washers are permanently installed in the tank Variable stroke lengths for cleaning: 3', 4' and 6' (.9, 1.2 and 1.8 m) Easy-to-use, manual panel controls the insertion/retraction of the RTW and nozzle rotation. The panel can be upgraded to include isolation valve actuation Control box/panel can be located away from the tank for safety or convenience. Position indicators on the panel show when the tank washer is fully inserted or retracted Optional isolation valve ensures liquid cannot escape from the tanks when tank washer is retracted and maintains pressure inside the vessel. Indicators show when valve is open or closed The retractable tank washer, optional isolation valve and manual control panel are completely air operated Ideal for Cleaning: Cosmetic tanks Food vats Pharmaceutical vessels PTFE, latex, acrylic, polymer, paint and other chemical reactors Contact your local sales engineer for performance data. Controller Retractable Tank Washer for tanks up to 40 (12 m) in dia. Specifications Max. tank dia.: High-pressure version: 40 (12 m) Standard version: 34 (10 m) Max. flow rate: High-pressure version: 21 gpm (80 l/min) Standard version: 44 gpm (170 l/min) Max. pressure: High-pressure version: 4000 psi (275 bar) Standard version: 500 psi (35 bar) Max. operating temperature: 140 F (60 C) Cycle time: 2.1 to 11 min coverage: 360 Inlet conn.: High-pressure version: ½ NPT or BSPT (F) Standard version: 1 NPT or BSPT (F) Stroke lengths: 3, 4 and 6 (.9, 1.2 and 1.8 m) Wetted parts: 316 and 304 stainless steel, synthetic rubber hose, PTFE, Viton * Weight: 187 to 253 lbs. (85 to 115 kg) *High-pressure version only. Viton is a registered trademark of DuPont Performance Elastomers.

83 Additional Products & Accessories Retractable Tank Washer (RTW) Specifications Variable stroke lengths: 3, 4 and 6 (.9, 1.2 and 1.8 m) Flange: 4 150# ANSI Designed to operate in a vertical position ANSI is a registered trademark of American National Standards Institute. Standard RTW fully retracted Standard RTW fully extended Retractable Tank Washer Options: Retractable Tank Washer High Pressure THA-300 Manual Control Standard AA190 Stroke Length 3' (0.9 m) 4' (1.2 m) Capacity Size 6' (1.8 m) + NOZZLE UP DOWN NOZZLE UP DOWN NOZZLE UP DOWN High Pressure 06, 10, 15, 20 AIR MOTOR Standard 10, 15, 20, 25, 30, 35, 40, 50, 60, 70, 80 Isolation Valve Manual Control Panel No Isolation Valve Isolation Valve Manual Control Panel RTW Without Isolation Valve Actuation With Isolation Valve Actuation 1111 Catalog 15 - RTW

84 TankJet BX Injector TankJet BX Injector Additional Products & Accessories Efficient Transformation of Steam and Cold Water into High-Pressure, High-Temperature Liquid Feeds Features and Benefits Ideal feed device for tank cleaning machines and custom-designed nozzle manifolds Non-intrusive: suitable for use with cold, low-pressure city water and existing plant steam Produces a high-pressure, high-temperature liquid discharge stream Increased pressure provides higher impact for cleaning tough residues Higher temperature speeds cleaning by quickly breaking down soil Eliminates the need for expensive pumps and heat exchangers Built-in overflow valve ensures safe operation Provides chemical injection via a liquid control valve that siphons chemicals or detergents to maximize cleaning efficiency TankJet BX Injector For liquid discharge capacities up to 110 gpm (416 l/min) How It Works Steam enters chamber and mixes with the cold water. Overflow valve prevents dangerous accidents from occurring due to burst pipes or any blockage downstream. The hot water passes through the venturi and expands. The water loses speed but gains pressure as it discharges. Detergent (if required) is metered in and mixed into the hot water stream. The cold water instantly condenses the hot steam and creates a vacuum. The cold water absorbs the heat and velocity from the steam and a high-speed stream of hot water is produced. The hot water will discharge at higher pressure than the inlet cold water pressure. The temperature rise can be up to 110 F (43 C) above the inlet water temperature. This liquid feeds tank cleaning machines and nozzle manifolds.

85 Additional Products & Accessories TankJet BX Injector Typical Application TankJet BX Injector Use in Rail Car Cleaning TankJet BX Injector feeds hot liquid into a TankJet 360 Tank Cleaning Machine. TankJet 360 provides thorough, quick and efficient cleaning of the rail car. The use of hot water shortens cleaning time. Performance Data Inlet Steam Pressure psi (bar) TankJet Injector No. Steam Capacity lbs/hr (kg/hr) 50 (3.4) 120 (8.3) 75 (5.2) 100 (6.9) 125 (8.6) Maximum Liquid Discharge Pressure psi (bar) 170 (11.7) 220 (15.2) 280 (19.3) 150 (10.3) 340 (23.4) Liquid Discharge Capacity gpm (l/min) TJBX-30 TJBX-50 TJBX to 3000 (454 to 1361) 1700 to 4500 (771 to 2041) 2500 to 6000 (1134 to 2722) 30 (114) 35 (132) 45 (170) 50 (189) 55 (208) 50 (189) 60 (227) 70 (265) 75 (284) 80 (303) 70 (265) 80 (303) 90 (341) 100 (379) 110 (416)

86 TankJet BX Injector Additional Products & Accessories Dimensions 27.3 (693 mm) 4.41 (112 mm) 11 (279 mm) Specifications Inlet steam pressure range: Steam capacity range: Max. liquid discharge pressure range: Liquid discharge flow rate range: Max. liquid discharge temperature: Inlet conn.: Outlet conn.: Weight: Materials: 50 to 150 psi (3.4 to 10.3 bar) 1000 to 6000 lbs/hr (454 to 2722 kgs/hr) 120 to 340 psi (8.3 to 23.4 bar) 30 to 110 gpm (114 to 416 l/min) 180 F (82 C) Steam: 1-1/2" NPT or BSPT (M); Water: 1-1/2" NPT or BSPT (M); Detergent: 1/2" NPT or BSPT (M) Discharge: 1-1/2" NPT or BSPT (M); Overflow: 2" NPT (F) or BSPT (M) 48 lbs (22 kg) Brass with 303SS detergent tube and EP O-ring Ordering Information TankJet BX Injector TJBX 30 * I I I Injector Model Conn. No. *Add B for BSPT connections. If NPT connection, leave blank.

87 Additional Products & Accessories TankJet BX Injector Tank Cleaning s Commonly Used with TankJet BX Injector TankJet Tank Cleaning s TJ-16 TJ-65 TJ-65-HT TJ-80-2 TJ-80-3 TJ TJ /Size in (mm) C, D, G H 1/4 (6.4) 5/16 (7.9) 3/8 (9.5) Compatible Injector Injector Steam Inlet Pressure Range psi (bar) Tank Cleaning s Operating Pressure Range psi (bar) Tank Cleaning s Flow Rate Range gpm (l/min) TJBX to 150 (6.9 to 10.3) 60 to 100 (4.1 to 6.9) 45 to 55 (170 to 208) TJBX50 50 to 150 (3.4 to 10.3) 80 to 200 (5.5 to 13.8) 50 to 80 (189 to 303) TJBX30 75 to 150 (5.2 to 10.3) 50 to 110 (3.4 to 7.6) 35 to 55 (132 to 208) TJBX50 50 to 125 (3.4 to 8.6) 95 to 200 (6.6 to 13.8) 50 to 75 (3.4 to 5.2) TJBX30 50 to 150 (3.4 to 10.3) 50 to 120 (3.4 to 8.3) 30 to 55 (114 to 208) TJBX50 50 to 75 (3.4 to 5.2) 105 to 140 (7.2 to 9.7) 50 to 60 (189 to 227) TJBX50 75 to 150 (5.2 to 10.3) 70 to 115 (4.8 to 7.9) 60 to 80 (227 to 303) TJBX70 50 to 100 (3.4 to 6.9) 90 to 150 (6.2 to 10.3) 70 to 90 (265 to 341) TJBX50 75 to 150 (5.2 to 10.3) 55 to 95 (3.8 to 6.6) 60 to 80 (227 to 303) TJBX70 50 to 125 (3.4 to 8.6) 75 to 150 (5.2 to 10.3) 70 to 100 (265 to 379) 1/4 (6.4) TJBX70 50 to 150 (3.4 to 10.3) 58 to 135 (4.0 to 9.3) 70 to 110 (265 to 416) 5/16 (7.9) TJBX70 50 to 150 (3.4 to 10.3) 55 to 115 (3.8 to 7.9) 70 to 110 (265 to 416) 3/8 (9.5) TJBX to 150 (6.9 to 10.3) 55 to 75 (3.8 to 5.2) 90 to 110 (341 to 416) 3/8 (9.5) 7/16 (11.1) 5/16 (7.9) TJBX50 50 to 150 (3.4 to 10.3) 50 to 130 (3.4 to 9.0) 50 to 80 (189 to 303) TJBX70 50 to 90 (3.4 to 6.2) 102 to 150 (7.0 to 10.3) 70 to 85 (265 to 322) TJBX50 90 to 150 (6.2 to 10.3) 65 to 105 (4.5 to 7.2) 65 to 80 (246 to 303) TJBX70 50 to 115 (3.4 to 7.9) 80 to 150 (5.5 to 10.3) 70 to 95 (265 to 360) TJBX50 75 to 150 (5.2 to 10.3) 60 to 125 (4.1 to 8.6) 60 to 80 (227 to 303) TJBX70 50 to 100 (3.4 to 6.9) 95 to 150 (6.6 to 10.3) 70 to 90 (265 to 341) 3/8 (9.5) TJBX to 150 (7.9 to 10.3) 68 to 110 (4.7 to 7.6) 95 to 110 (360 to 416) 1/4 (6.4) 9/32 (7.1) 5/16 (7.9) 3/8 (9.5) TJBX30 50 to 150 (3.4 to 10.3) 40 to 150 (2.8 to 10.3) 30 to 55 (114 to 208) TJBX50 50 to 150 (3.4 to 10.3) 120 to 340 (8.3 to 23.4) 50 to 80 (189 to 303) TJBX30 75 to 150 (5.2 to 10.3) 40 to 110 (2.8 to 7.6) 35 to 55 (132 to 208) TJBX50 50 to 150 (3.4 to 10.3) 80 to 220 (5.5 to 15.2) 50 to 80 (189 to 303) TJBX70 50 to 125 (3.4 to 8.6) 170 to 350 (11.7 to 24.1) 70 to 100 (265 to 379) TJBX to 150 (7.9 to 10.3) 40 to 55 (2.8 to 3.8) 40 to 75 (151 to 284) TJBX50 50 to 150 (3.4 to 10.3) 60 to 155 (4.1 to 10.7) 50 to 80 (189 to 303) TJBX70 50 to 150 (3.4 to 10.3) 120 to 290 (8.3 to 20.0) 70 to 110 (265 to 416) TJBX50 60 to 150 (4.1 to 10.3) 40 to 90 (2.8 to 6.2) 55 to 80 (208 to 303) TJBX70 50 to 150 (3.4 to 10.3) 70 to 165 (4.8 to 11.4) 70 to 110 (265 to 416) 7/16 (11.1) TJBX70 50 to 150 (3.4 to 10.3) 45 to 105 (3.1 to 7.2) 70 to 110 (265 to 416) 1/2 (12.7) TJBX70 75 to 150 (5.2 to 10.3) 40 to 75 (2.8 to 5.2) 80 to 110 (303 to 416) 9/16 (14.3) TJBX70 90 to 150 (6.2 to 10.3) 40 to 55 (2.8 to 3.8) 90 to 110 (341 to 416) 1/4 (6.4) 9/32 (7.1) 5/16 (7.9) TJBX30 90 to 150 (6.2 to 10.3) 40 to 72 (2.8 to 5.0) 40 to 55 (151 to 208) TJBX50 50 to 150 (3.4 to 10.3) 60 to 155 (4.1 to 10.7) 50 to 80 (189 to 303) TJBX70 50 to 150 (3.4 to 10.3) 120 to 290 (8.3 to 20.0) 70 to 110 (265 to 416) TJBX50 50 to 150 (3.4 to 10.3) 40 to 110 (2.8 to 7.6) 50 to 80 (189 to 303) TJBX70 50 to 150 (3.4 to 10.3) 80 to 205 (5.5 to 14.1) 70 to 110 (265 to 416) TJBX50 65 to 150 (4.5 to 10.3) 40 to 80 (2.8 to 5.5) 55 to 80 (208 to 303) TJBX70 50 to 150 (3.4 to 10.3) 60 to 150 (4.1 to 10.3) 70 to 110 (265 to 416) 3/8 (9.5) TJBX70 50 to 150 (3.4 to 10.3) 40 to 90 (2.8 to 6.2) 70 to 110 (265 to 416) 7/16 (11.1) TJBX to 150 (6.9 to 10.3) 40 to 60 (2.8 to 4.1) 90 to 110 (341 to 416) Catalog 15 - TankJet BX Injector

88 TankJet B Injector TankJet B Injector Additional Products & Accessories Efficient Transformation of Steam and Cold Water into High-Pressure, High-Temperature Liquid Feeds Features and Benefits Ideal feed device for tank cleaning machines and custom-designed nozzle manifolds Non-intrusive: suitable for use with cold, low-pressure city water and existing plant steam Produces a high-pressure, high-temperature liquid discharge stream Increased pressure provides higher impact for cleaning tough residues Higher temperature speeds cleaning by quickly breaking down soil Eliminates the need for expensive pumps and heat exchangers Built-in overflow valve ensures safe operation Provides chemical injection via a liquid control valve that siphons chemicals or detergents to maximize cleaning efficiency TankJet B Injector For liquid discharge capacities up to 34 gpm (129 l/min) How It Works Steam enters chamber and mixes with the cold water. Overflow valve prevents dangerous accidents from occurring due to burst pipes or any blockage downstream. The hot water passes through the venturi and expands. The water loses speed but gains pressure as it discharges. Detergent (if required) is metered in and mixed into the hot water stream. The cold water instantly condenses the hot steam and creates a vacuum. The cold water absorbs the heat and velocity from the steam and a high-speed stream of hot water is produced. The hot water will discharge at higher pressure than the inlet cold water pressure. The temperature rise can be up to 110 F (43 C) above the inlet water temperature. This liquid feeds tank cleaning machines and nozzle manifolds.

89 Additional Products & Accessories TankJet B Injector Typical Application TankJet B Injector Use in Tote Cleaning TankJet B Injector feeds hot liquid into a TankJet Tank Cleaning Machine. TankJet provides thorough, quick and efficient cleaning of the tote. The use of hot water shortens cleaning time. Performance Data Inlet Steam Pressure psi (bar) TankJet Injector No. Steam Capacity lbs/hr (kg/hr) 50 (3.4) 120 (8.3) 75 (5.2) 100 (6.9) 125 (8.6) Maximum Liquid Discharge Pressure psi (bar) 170 (11.7) 220 (15.2) 280 (19.3) 150 (10.3) 340 (23.4) Liquid Discharge Capacity gpm (l/min) TJB-4 TJB-7 TJB-9 TJB-15 TJB to 400 (73 to 182) 280 to 700 (127 to 318) 360 to 900 (163 to 408) 700 to 1500 (318 to 680) 800 to 2000 (363 to 907) 4 (15.1) 4.5 (17.0) 5.5 (21) 6 (23) 6.5 (25) 7 (26) 8 (30) 9 (34) 10.5 (40) 12 (45) 9 (34) 12 (45) 13 (49) 15 (57) 16.5 (62) 15 (57) 20 (76) 24 (91) 27 (102) 29 (110) 20 (76) 25 (95) 29 (110) 32 (121) 34 (129)

90 TankJet B Injector Additional Products & Accessories Dimensions Max. (558 mm) 3.48 (88 mm) 9.24 (235 mm) Specifications Inlet steam pressure range: Steam capacity range: Max. liquid discharge pressure range: Liquid discharge flow rate range: Max. liquid discharge temperature: Inlet conn.: Outlet conn.: Weight: Materials: 50 to 150 psi (3.4 to 10.3 bar) 160 to 2000 lbs/hr (73 to 907 kgs/hr) 120 to 340 psi (8.3 to 23.4 bar) 4 to 34 gpm (15 to l/min) 180 F (82 C) Steam: 1-1/4" NPT or BSPT (M); Water: 1-1/4" NPT or BSPT (M); Detergent: 1/2" NPT or BSPT (M) Discharge: 3/4" NPT or BSPT (F); Overflow: 1" NPT (F) or BSPT (M) 24 lbs (11 kg) Brass with 303SS detergent tube and EP O-ring Ordering Information TankJet B Injector TJB 4 * I I I Injector Model Conn. No. *Add B for BSPT connections. If NPT connection, leave blank.

91 Additional Products & Accessories TankJet B Injector Tank Cleaning s Commonly Used with TankJet B Injector TankJet Tank Cleaning s /Size Compatible Injector Injector Steam Inlet Pressure Range psi (bar) Tank Cleaning s Operating Pressure Range psi (bar) Tank Cleaning s Flow Rate Range gpm (l/min) TJ-14 TJ-19 TJ C G, H D C D G H LP TJB to 150 (4.1 to 10.3) 50 to 150 (3.4 to 10.3) 17 to 29 (64 to 110) TJB to 150 (3.4 to 10.3) 70 to 200 (4.8 to 13.8) 20 to 34 (76 to 129) TJB to 150 (3.8 to 10.3) 50 to 170 (3.4 to 11.7) 16 to 29 (61 to 110) TJB to 125 (3.4 to 8.6) 80 to 200 (5.5 to 13.8) 20 to 32 (76 to 121) TJB to 140 (3.4 to 9.7) 60 to 200 (4.1 to 13.8) 15 to 28 (57 to 106) TJB to 90 (3.4 to 6.2) 110 to 200 (7.6 to 13.8) 20 to 28 (76 to 106) TJB to 150 (4.1 to 10.3) 50 to 190 (3.4 to 13.1) 17 to 29 (64 to 110) TJB to 110 (3.4 to 7.6) 80 to 200 (5.5 to 13.8) 20 to 30 (76 to 114) TJB to 150 (3.4 to 10.3) 50 to 200 (3.4 to 13.8) 15 to 29 (57 to 110) TJB to 100 (3.4 to 6.9) 90 to 200 (6.2 to 6.2) 20 to 29 (76 to 110) TJB-9 75 to 150 (5.2 to 10.3) 50 to 90 (3.4 to 6.2) 12 to 16.5 (45 to 62) TJB to 120 (3.4 to 8.3) 80 to 200 (5.5 to 13.8) 15 to 26 (57 to 98) TJB to 85 (3.4 to 5.9) 130 to 200 (9.0 to 13.8) 20 to 26 (76 to 98) TJB-9 60 to 150 (4.1 to 10.3) 50 to 100 (3.4 to 6.9) 10 to 16.5 (38 to 62) TJB to 100 (3.4 to 6.9) 90 to 200 (6.2 to 6.2) 15 to 24 (57 to 91) TJB to 70 (3.4 to 4.8) 150 to 200 (10.3 to 13.8) 20 to 24 (76 to 91) TJB to 125 (5.2 to 8.6) 150 to 300 (10.3 to 20.7) 20 to 27 (76 to 102) TJB to 90 (3.4 to 6.2) 150 to 300 (10.3 to 20.7) 20 to 27 (76 to 102) TJB to 150 (6.9 to 10.3) 50 to 120 (3.4 to 8.3) 13 to 16.5 (49 to 62) TJB to 70 (3.4 to 4.8) 100 to 150 (6.9 to 10.3) 15 to 19 (57 to 72) 172 TJB to 90 (3.4 to 6.2) 150 to 300 (10.3 to 20.7) 15 to 22 (57 to 83) 172LP TJB-9 60 to 125 (4.1 to 8.6) 70 to 150 (4.8 to 10.3) 10 to 15 (38 to 57) TJ LP TJB to 150 (7.6 to 10.3) 150 to 210 (10.3 to 14.5) 25 to 29 (95 to 110) TJB to 150 (5.2 to 10.3) 150 to 280 (10.3 to 19.3) 25 to 35 (95 to 132) TJB-9 75 to 150 (5.2 to 10.3) 50 to 90 (3.4 to 6.2) 12 to 16.5 (45 to 62) TJB to 85 (3.4 to 5.9) 80 to 150 (5.5 to 10.3) 15 to 21 (57 to 79) 125 TJB to 95 (3.8 to 6.6) 150 to 300 (10.3 to 20.7) 16 to 23 (61 to 87) 125LP TJB to 150 (6.9 to 10.3) 50 to 100 (3.4 to 6.9) 9 to 12 (34 to 45) TJB-9 50 to 125 (3.4 to 8.6) 50 to 140 (3.4 to 9.7) 9 to 15 (34 to 57) 0411 Catalog 15 - TankJet B Injector

92 TankJet Accessories Additional Products & Accessories TankJet Accessories Simplify Installation, Optimize Performance Adjustable Flange Choice of 2-1/2, 3, 4 or 6 tri-clamp fittings Adjustable Flanges for TankJet AA190 and AA090 tank cleaners Three-prong Adjustable Flange Can be used with TankJet AA090 and AA190 tank cleaners Features and Benefits Maximize cleaning effectiveness by positioning nozzle turret to clean around obstructions or targeting skim lines or other areas requiring extra impact Standard adjustable flanges allow positioning the nozzles at various depths along the length of the extension Adjustable ball swivel flanges allow adjustment of the spray head by as much as 60 Choice of connections: tri-clamp fitting, three-prong flange, 150# flange connection Ball Swivel Adjustable Flange Choose 4 or 6 150# adjustable ball swivel flanges. 4 sanitary version also available Raised Face Adjustable Flange Choice of 2, 3 or 4 150# raised face flanges Adapters and Mounting Kits Features and Benefits Manway Adapter Includes vent for vapor release, shield to prevent liquid from spraying into vent and removable plug that allows cone to be filled with liquid if additional weight is desired Tapered manway adapter enables drop-in-place installation of the TankJet 360 with tanker truck openings between 17 and 21 (432 and 533 mm); 304 stainless steel construction Chemically-resistant adapter enables any air or electric TankJet AA090 or AA190 tank cleaner to be used in tanks with inlet sizes ranging from 2 to 4 Simplify mounting the standard TankJet AA190 4 three-prong flange to a 4 150# flange. Kit includes a stainless steel raised face flange, stainless steel lock washers, bolts and PTFE gasket Adapter for TankJet AA090 and AA190 Tank Cleaners Has a 6.25 OD, Celcon construction with 304 stainless steel screws Mounting Kit Includes everything you need flange, lock washers, bolts and gasket Celcon is a registered trademark of Celanese Corporation.

93 Additional Products & Accessories TankJet Accessories Ordering Information Adjustable Flange SS Adapter I I I Flange Size Model No. Three-prong Adjustable Flange CE I Model No. Material Code SS I Model No. I Material Code I Material Code Raised Face Adjustable Flange SS I I I Flange Size Model No. Ball Swivel Adjustable Flange SS Model No. Mounting Kit SS Model No. Material Code I I I Flange Size Material Code I I I Flange Size Material Code Manway Adapter Dimensions and Weights Model No. Length Outside Diameter Weight Adjustable Flange for Tanks with Tri-Clamp Fitting /2 4-3/4" (121 mm) 3" (76 mm) 2 lbs. (.9 kg) /4 (121 mm) 3.6 (91 mm) 2.1 lbs. (.95 kg) /4 (121 mm) 4.7 (119 mm) 2.5 lbs. (1.1 kg) /4 (121 mm) 6.6 (168 mm) 5.3 lbs. (2.4 kg) Adjustable Three-Prong Flange /16" (103 mm) 5" (127 mm) 2.8 lbs. (1.3 kg) Adjustable Flange for Tanks with 150# Connections /16" (122 mm) 6" (152 mm) 12 lbs. (5.4 kg) /16" (125 mm) 7.5" (191 mm) 12.9 lbs. (5.9 kg) " (127 mm) 9" (229 mm) 17.7 lbs. (8.0 kg) Ball Swivel Adjustable Flange /4" (172 mm) 9" (229 mm) 20 lbs. (9.1 kg) /4" (172 mm) 11" (279 mm) 30 lbs. (13.6 kg) Tapered Manway with 1-1/2" NPT (M) Both Ends Adapter SS I Model No. Mounting Kit I Material Code " (1,168 mm) 22" (559 mm) 75 lbs. (34 kg) /16" 6.25" (159 mm) 1 lb. (.45 kg) /16" (24 mm) 9" (229 mm) 15 lbs. (6.8 kg) 0211 Catalog 15 - Accessories

94 Let Us Help Optimize Your Tank Cleaning Operations New TankJet 360 is available in low-flow and flow-through versions. Choose from two- or three-nozzle designs. Tell us about: The size of your tank The residue that needs to be cleaned The cleaning liquid used And we ll tell you which of our many automated tank cleaning products is right for the job. With a newly expanded product line, we have solutions for: Gentle rinsing to high-impact cleaning to remove stubborn residues Containers with diameters as small as 2 and tanks as large as 100 Portable or clean-in-place operation Plus, we offer: Unmatched service dedicated, local sales engineers ready to help optimize your operations Free on-site evaluations, trial programs on some products, lease programs and more Call SPRAY or visit for more information. North Avenue and Schmale Road, P.O. Box 7900, Wheaton, IL USA Tel: SPRAY Intl. Tel: Fax: SPRAY Intl. Fax: s Control Analysis Fabrication Bulletin No. 688 Printed in the U.S.A. ing Systems Co. 2011

Optimizing Tank Cleaning Operations

Optimizing Tank Cleaning Operations Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you

More information

Section I Tank Wash Products

Section I Tank Wash Products Section I Overview This section provides an overview of our automated tank cleaning systems, tank washers and tank wash nozzles. You ll find clean-in-place and portable solutions to help automate rinsing,

More information

HOW TO GET TANKS & TOTES CLEANER IN LESS TIME & LOWER COSTS

HOW TO GET TANKS & TOTES CLEANER IN LESS TIME & LOWER COSTS HOW TO GET TANKS & TOTES CLEANER IN LESS TIME & LOWER COSTS BY ANTHONY WOOD INTRODUCTION Most people understand and appreciate the benefits of automated tank cleaning cleaner tanks in less time, reduced

More information

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors s Control Analysis Fabrication A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors Eductors Ensure Thorough Mixing to Improve Product Quality and Reduce Maintenance Time Tank mixing eductors

More information

Cost Savings Gained through Rotary Impingement Tank Cleaning

Cost Savings Gained through Rotary Impingement Tank Cleaning Gamajet Cleaning Systems, Inc. Exton, Pennsylvania August 2012 Cost Savings Gained through Rotary Impingement Tank Cleaning Abstract: Specific case studies on the benefits of rotary impingement and CIP

More information

Increasing Productivity and Reducing Costs with CIP Optimization

Increasing Productivity and Reducing Costs with CIP Optimization Gamajet Cleaning Systems, Inc. Exton, Pennsylvania April 2012 Increasing Productivity and Reducing Costs with CIP Optimization Abstract: Case studies on the benefits of CIP optimization and rotary impingement

More information

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps P/N: DEF-0613A Diesel Exhaust Fluid (DEF) Pumps DEF Solutions Standard Pump has designed a range of unique, preconfigured DEF Pump Packages that are engineered to transfer AdBlue (AUS32) Diesel Exhaust

More information

How to Pre-empt a Significant Profit Drain: Nozzle Wear

How to Pre-empt a Significant Profit Drain: Nozzle Wear Experts in Technology Nozzles Control Analysis Fabrication How to Pre-empt a Significant Profit Drain: Nozzle Wear Causes, Detection and Corrective Action Strategies By Jon Barber, ing Systems Co. KEY

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2. May 3, 2013 Foam 138a 1. DESCRIPTION Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specific design area upon system activation. These are suitable for use

More information

Rotary Tank Cleaning and Cost Savings

Rotary Tank Cleaning and Cost Savings Rotary Tank Cleaning and Cost Savings Gamajet Cleaning Systems, Inc. Exton, Pennsylvania June 2011 Abstract: Specific case studies on the benefits of rotary impingement and CIP optimization vs. the standard

More information

CHEMICAL CLEANING UNIT Product number: 737189

CHEMICAL CLEANING UNIT Product number: 737189 CHEMICAL CLEANING UNIT Product number: 737189-1 - v.05/16 Content Page Intro 3 Specifications 4 Installation 5 Safety precautions 7 Maintenance 8 Spares and Accessories 8 Unitor Chemicals 9 Notes 10-2

More information

Industrial Electric Monitors. Industrial

Industrial Electric Monitors. Industrial Industrial Electric Monitors Corrosion resistant monitors with maximum travel for optimal coverage in industrial, mining and marine environments. Severe-Duty Monitor 750 GPM (2900 LPM) The Severe-Duty,

More information

ENGLISH FORK GUIDE 2013

ENGLISH FORK GUIDE 2013 FORK GUIDE 2013 ENGLISH 1 With a brand which is synonymous with specialists in forest products handling attachments, BOLZONI AURAMO offers its expertise and market leading attachments for all requirements,

More information

Pipe Cutting and Beveling Clamshells

Pipe Cutting and Beveling Clamshells Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international

More information

400B SERIES DIAPHRAGM PUMP

400B SERIES DIAPHRAGM PUMP 400B SERIES DIAPHRAGM PUMP In today s agricultural and industrial markets, isn t it good to know that you can rely on one name Sotera to fit your chemical transfer needs? The Sotera 400B Series offers

More information

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Parts and Equipment Washing, Rinsing and Drying Using Spray Technology

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Parts and Equipment Washing, Rinsing and Drying Using Spray Technology Spray Nozzles Spray Control Spray Analysis Spray Fabrication A Guide to Parts and Equipment Washing, Rinsing and Drying Using Spray Technology Table of Contents Application Nozzle Type Rinsing Washing

More information

Change the Way You Spray to Minimize Clogging

Change the Way You Spray to Minimize Clogging Nozzles Control Analysis Fabrication Change the Way You to Minimize Clogging By Jon Barber, ing Systems Co. nozzles appear to be simple devices, but in service they function as highly precise instruments.

More information

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

WANJET. Sprayers. Wanjet sprayers has been produced since 1978. Sprayers Wanjet sprayers has been produced since 1978. Already from beginning was our assortment mainly based on high pressure sprayers with a pressure up to 150 bar. The idea about the high pressure is

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Redefining Spray Technology

Redefining Spray Technology Redefining Spray Technology Macrospray Single-Point Nozzles Macrospray Spider Nozzles Macrospray nozzle technology Improved performance, lower cost Macrospray nozzle technology from Parker Hannifin s Gas

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

Guth Portable gitators R The long-term solution pplications Guth Portable gitators R are used for the mixing, stirring and the homogenization of water-like or medium viscosity products. They are most often

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

AIR OPERATED OIL PUMPS AND KITS

AIR OPERATED OIL PUMPS AND KITS PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water

More information

REVOLUTION TANK CLEANING IT S A. Tank Cleaning Machines and Systems

REVOLUTION TANK CLEANING IT S A. Tank Cleaning Machines and Systems IT S A TANK CLEANING REVOLUTION 80% Decrease in Water and Chemical Usage 85% Decrease in Time Spent Cleaning 100% Decrease in Manual Cleaning 100% Cleaning Effectiveness Tank Cleaning Machines and Systems

More information

Operating, Installation, and Maintenance Instructions

Operating, Installation, and Maintenance Instructions ELKHART BRASS MFG. CO., INC. 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 Operating, Installation, and Maintenance Instructions RAM Personal Portable Monitor

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

MONITOR SECTION INDEX

MONITOR SECTION INDEX MONITOR SECTION INDEX Daspit Tool... E2 Daspit Tool - Truck Mount... E3 Daspit Tool - Throw Down Model... E4 Alpha MA-HV4-4 Aluminum Tiller Bar Monitor... E5 Alpha-E Tiller Bar Montior - 3... E6 SharpShooter

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022

More information

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw.

Compact pumps from the wastewater experts. FLYGT 3045, 3057, 3068. Power range 0.75 2.4 kw. Compact pumps from the wastewater experts FLYGT 304, 307, 3068. Power range 0.7.4 kw. Wastewater is unpredictable, Flygt pumps are not If you want a wastewater pump that just works month after month, year

More information

History. between Consilium & Toftejorg. Toftejorg A/S. 1/1-2003 Acquired by Alfa Laval Group. www.alfalaval.com. Alfa Laval Slide 3

History. between Consilium & Toftejorg. Toftejorg A/S. 1/1-2003 Acquired by Alfa Laval Group. www.alfalaval.com. Alfa Laval Slide 3 History Toftejorg 1953 1 st dual nozzle machine developed by Mr Tofte and Mr Jörgensen (Superintendent of Maersk) 1957 Company Tofte & Jorgensen was formed 1986 Toftejorg was formed Gunclean 1965 Seatrial

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Cost-effective solutions for all applications.

Cost-effective solutions for all applications. Professional Pressure Washers Hard Surface Cleaners NEW Cost-effective solutions for all applications. Pressure washer performance for hard-surfaces. Pressure washer performance made easy. Kärcher hard-surface

More information

In-Line Air Separators

In-Line Air Separators Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI

More information

Automatic Self-Cleaning Strainers

Automatic Self-Cleaning Strainers Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning

More information

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted

More information

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION OPERATING INSTRUCTIONS Shortening Filter Model No. 99-A, 102-A, & 107-A Series TABLE OF CONTENTS PAGE Installation... 2 Operating... 3 Cleaning... 5 Parts List... 6 & 7 Troubleshooting... 8 LIMITED WARRANTY

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

LINEAR MOTION CONTROL

LINEAR MOTION CONTROL LINEAR MOTION CONTROL Technical Data Sheet Static Locks RLSS Series Nexen s new generation of linear holding/locking devices take rod locking technology to the next level. With superior performance, these

More information

Industrial Monitors. Weight lbs. (Kg) Style. 55* (24.9 kg) 14"** (356 mm) * Less nozzle ** Less handle. Weight lbs. (kg) Style. 21 3 / 16"** (538 mm)

Industrial Monitors. Weight lbs. (Kg) Style. 55* (24.9 kg) 14** (356 mm) * Less nozzle ** Less handle. Weight lbs. (kg) Style. 21 3 / 16** (538 mm) Industrial Monitors Omega XP Monitor The Omega XP brass monitor offers maximum travel for optimal coverage in industrial and marine environments. AKRON BRASS COMPANY PH. 800.228.1161 (330.264.5678) FAX

More information

HYDROSTATIC TEST PUMPS

HYDROSTATIC TEST PUMPS HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy

More information

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

NDP-50 Specifications

NDP-50 Specifications NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves Baumann TM Sanitary and Aseptic Process Valves The Company Fisher Controls International LLC, Baumann Control Valves, is an ISO 9001 certified, PED compliant manufacturer of general utility, precision

More information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24 Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

45 URAI DSL 816-741-0282. Roots. Quick Specs. Also Available in: Part Number T30353020

45 URAI DSL 816-741-0282. Roots. Quick Specs. Also Available in: Part Number T30353020 45 URAI DSL Part Number T30353020 Detachable steel mounting feet Rigid one piece cast iron casing Connections in standard pipe sizes Straight, precision machined two lobe impellers Splash oil lubricated

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

Product catalogue, pipe and sewer cleaning systems

Product catalogue, pipe and sewer cleaning systems Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

Removing Solids with Automatic Self-Cleaning Filters

Removing Solids with Automatic Self-Cleaning Filters THE 15 TH ANNUAL PRODUCED WATER SEMINAR Nassau Bay Hilton Hotel 3000 Nasa Road One Houston, Texas 77058 January 19-21, 2005 Marcus N. Allhands, Ph.D., P.E. Senior Application Engineer Amiad Filtration

More information

Machine needle shut-off nozzle type-a

Machine needle shut-off nozzle type-a Machine needle shut-off nozzle type-a spring operated Applications: Thermoplastics (not applicable for PVC) Shut-off mechanism: Operated with one axial high performance spring Index of contents Chapter

More information

Pump Ratio and Performance Charts

Pump Ratio and Performance Charts Pump Ratio and Performance Charts Concept and Theory Training Table of Contents Introduction... 1 Overview... 1 How to use this Module... 2 Learning Objectives...2 Text...2 Charts, Illustrations...2 Progress

More information

Autoclave Engineers. Laboratory Stirred Reactors. Stirred Reactors

Autoclave Engineers. Laboratory Stirred Reactors. Stirred Reactors Autoclave Engineers Laboratory Stirred Reactors Stirred Reactors Stirred Reactors Autoclave Engineers has been associated with excellence in pressurized reaction equipment for over 50 years. Autoclave

More information

Roller Chain Coupling

Roller Chain Coupling Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving

More information

UNITOR VACUUM cleaners

UNITOR VACUUM cleaners UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.

More information

Bringing good things ahead

Bringing good things ahead Bringing good things ahead Whatever your logistic needs, we can offer a conveyor solution. Our flexible systems primary and secondary packaging for single and multi packages, can transport your goods from

More information

Application Data Important Safety Information

Application Data Important Safety Information Application Data Important Safety Information Read this page before using any of the information in this catalog. This catalog is designed to be used as a guide in selecting the proper hose for the applications

More information

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING Flygt The Concept N-Pump series. Bringing NEW levels of efficiency to wastewater handling applications Reduced pumping efficiency,

More information

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,

More information

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a

More information

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps grundfos se & sl ranges Submersible and dry-installed wastewater pumps 0.9-30 kw 2, 4, 6 pole 50Hz No compromise Highest total efficiency wastewater pumping ULTIMATE WASTEWATER PUMPING TECHNOLOGY The renewed

More information

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling

Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life

More information

http://www.cieplowniasiemianowice.pl/filtry.html

http://www.cieplowniasiemianowice.pl/filtry.html Oil skimmer is a device which helps remove surface oil. Skimmer is mounted in the selection location. An oil is absorbed by the teflon tape and is removed for example from bath to another external container

More information

Shaft No. of Part No. Model No. Housing Rotation dia Rollers Seals

Shaft No. of Part No. Model No. Housing Rotation dia Rollers Seals Hypro Roller Pumps Ideal for Farm Sprayers, Pest Control and Chemical Application Usage. Housings available in Cast Iron, Ni-Resist or Silver Series Self priming operation; Roller pumps should not be run

More information

VAD. Variable Area Desuperheaters

VAD. Variable Area Desuperheaters Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated

More information

High Capacity Hot Air Dryer

High Capacity Hot Air Dryer High Capacity Hot Air Dryer MADE IN AUSTRIA autumn 2015 www.zimmer-austria.com page 1 Hot air dryer type: Compact HC The modular construction of the high efficiency and powerful hot air nozzle dryer is

More information

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE. www.sharpevalves.

Valves, Automation & Controls. series 84 /99 HIGH PERFORMANCE 3-PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE. www.sharpevalves. Valves, Automation & Controls series 8 /99 & FS8 /FS99 HIGH PERFORMANCE -PIECE BALL VALVE REDUCE & FULL PORT, STANDARD & FIRE SAFE www.sharpevalves.com Design & Features SHARPE VALVES - SERIES 8/99 Fire

More information

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited PRODUCT RELEASE CKMTA12 / 24 Copyright 2011 by ARB Corporation Limited ARB 4x4 ACCESSORIES 720 SW 34Th Street Tel: (425) 264-1391 Renton, Washington 98057 Fax: (425) 264-1392 USA North and South American

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems

Vision Engravers and Routers PRE-Installation Guide. 2015 Vision Engraving & Routing Systems Vision Engravers and Routers PRE-Installation Guide Revised: 8/19/2015 Vision Engravers and Routers PRE-Installation Guide All rights reserved. No parts of this work may be reproduced in any form or by

More information

ROUGHNECK II Pumpless Drain

ROUGHNECK II Pumpless Drain SERVICE BULLETIN SB4027 Rev. I 1/11 For Used Oil Only ROUGHNECK II Pumpless Drain Model #4110-022 FOR USED OIL ONLY (Black) For Antifreeze Only Model #4110-023 FOR USED ANTIFREEZE ONLY (Green) Patent #

More information

Handling Corrosive or Abrasive Liquids

Handling Corrosive or Abrasive Liquids Handling Corrosive or Abrasive Liquids Defining abrasion and corrosion An abrasive liquid is one that has particles in it. Some, like inks, have very fine particles, while others, like some paints, contain

More information

2013 WJTA-IMCA Conference and Expo September 9-11, 2013 Houston, Texas Paper REFRACTORY REMOVAL BY HIGH PRESSURE WATERJET

2013 WJTA-IMCA Conference and Expo September 9-11, 2013 Houston, Texas Paper REFRACTORY REMOVAL BY HIGH PRESSURE WATERJET 2013 WJTA-IMCA Conference and Expo September 9-11, 2013 Houston, Texas Paper REFRACTORY REMOVAL BY HIGH PRESSURE WATERJET D. Wright StoneAge, Inc. Durango, Colorado, U.S.A. ABSTRACT The removal of refractory

More information

Electronic faucets for every occasion, every application

Electronic faucets for every occasion, every application Electronic Faucets Electronic Faucets Electronic faucets for every occasion, every application With above-deck electronics and other exclusive features, Chicago Faucets electronic products are an ideal

More information

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY

More information

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To: Sewer Jetter GuideSM How to Unclog Drains with Your Pressure Washer Use this Guide To: Learn how a sewer jetter works Find out if a sewer jetter can help solve your plumbing problem Choose the right pressure

More information