High Volume PM10/TSP Calibration/Verification/Audit Guidance. Issued: 12/15/14 - FINAL

Size: px
Start display at page:

Download "High Volume PM10/TSP Calibration/Verification/Audit Guidance. Issued: 12/15/14 - FINAL"

Transcription

1 High Volume PM10/TSP Calibration/Verification/Audit Guidance Issued: 12/15/14 - FINAL Purpose: The purpose of this guidance is to assist operators of industrial particulate samplers for particulate matter less than 10 microns in diameter (PM10) or total suspended particulate (TSP) in performing calibrations, verifications and provide better understanding of audits to ensure greater operational consistency throughout the network. Disclaimer: This document is intended solely as guidance and does not contain any mandatory requirements except where requirements found in statute or administrative rule are referenced. This guidance does not establish or affect legal rights or obligations and is not finally determinative of any of the issues addressed. This guidance does not create any rights enforceable by any party in litigation with the State of Wisconsin or the Department of Natural Resources. Any regulatory decisions made by the Department of Natural Resources in any matter addressed by this guidance will be made by applying the governing statutes and administrative rules to the relevant facts. Issue: In recent years there has been a large increase in the number of facilities and consultants operating high volume PM10 or TSP samplers. These samplers have several methods of flow controls and facilities/consultants may have their own individual procedures for flow calibration and determination. Additionally the Wisconsin Department of Natural Resources (WDNR) upgraded its network to volumetrically controlled samplers in 2012 and has updated its internal calibration, verification and audit procedures as well. The increased number of operators and the variety of methods has resulted in some inconsistency across the industrial monitoring network and confusion about the audit procedures used to assure the data. Use of PM10 monitors has become typical in recent years because the secondary 24-hour ambient air quality standard for TSP was suspended in Wisconsin on 12/1/2011 to become consistent with the national ambient air quality standards. However, TSP samples are still collected at some sites for secondary analysis for lead or as a surrogate for PM10. Proposal: WDNR acknowledges that there are several accepted methods for the calibration of high volume samplers that yield similar results. WDNR recommends that all calibrations be done in terms of actual conditions. Some flexibility in calibration method is acceptable, and methods will be evaluated during annual audits that are performed with a standard method. Additionally WDNR is providing guidance for calibrations and flow calculations for common types of samplers. This guidance will include spreadsheet templates for calibrations and QC checks that can be used by facilities and consultants. Use of these templates is not a requirement; they are provided as a guide.

2 Temperature/Pressure Most calibrations and flow measurements are pressure and temperature dependent. As a result, it is strongly recommended that any calibration/verification activity includes temperature and pressure measurements using annually certified standards. Per 40 CFR Part 50 Appendix J, PM10 flow rates must be maintained within 10% of 1.13 m 3 /minute in local conditions for samples to be valid. Therefore most flow controls should be adjusted to meet actual conditions. However, PM10 and TSP measurements should be reported in standard conditions µg/std m 3 (760 mm Hg, 25 C/298 K). The conversion from measured flow rates in actual conditions to standard conditions is done by the equation: Qstd = Qa * (Pa/760) * (298/Ta) Where: Qstd = flow rate in standard conditions Qa = flow rate in actual conditions Pa = ambient sampling pressure (mm Hg) Ta = ambient sampling temperature (K) Ambient pressure and temperature can be measured on site, can be taken from a nearby weather station, or can be estimated using seasonal temperatures. On site Temperature and Pressure: On-site temperature and pressure should be calibrated or verified with a certified standard. Barometric pressure should measure ambient pressure, not corrected to sea level. Weather Station: The weather stations used for determining temperature and pressure should be identified in the cover letter of the report. CAUTION: Weather stations normally report barometric pressure corrected to sea level. If this is the case, the site operator will need to correct barometric pressure back to station pressure by correcting it for the elevation of the sampler. WDNR suggests this equation: BPstation = BPsea-level 1.08*(elevation in feet/1000) Seasonal Temperature and Pressure: WDNR uses the following seasonal temperatures and pressures. This is subject to be updated in the future.

3 Wisconsin Average Temp and Pressure: Seasonal Average Temp South of US Hwy 8 ( C) Seasonal Average Temp North of US Hwy 8 ( C) Seasonal Average Barometric Pressure Dec/Jan/Feb March/Apr/May Jun/Jul/Aug/Sept Oct/Nov -8.3 C +6.8 C C +6.8 C -8.3 C +3.1 C C +6.8 C mm Hg mm Hg mm Hg mm Hg Flow Calibration Standard In all cases WDNR recommends using an orifice calibrated with a slope and intercept in actual conditions. If a flow standard with a different principle (calibrated in terms of standard or theoretical conditions) is used, it should be clearly documented and explained in the monitoring plan and should be indicated in any calibration report. Sampler Types Currently, there are three main types of monitors being used that differ primarily in the mechanism used for flow control and calculation: Volumetric Controlled (choked flow venturi), Mass Flow Controlled (automated MFC or rheostat) and Computer Controlled. These flow controls can be used for either PM10 or TSP samplers. Each type is described below along with WDNR recommendations for calibration methods, monthly verifications and the audit procedures that will be used by WDNR.

4 Suggested Action Levels WDNR recommends the following action levels when doing checks of high volume samplers and associated equipment. These recommendations are based on criteria found in 40 CFR Part 50 Appendix J and DNR standard operating procedures. Orifice measured flow rate versus Instrument flow rate (may be looked up, calculated from a Dickson, or displayed depending on instrument type) o >5% - should result in corrective maintenance or recalibration o >7% - the data bracketed by the check should be considered for invalidation Orifice measured flow rate or Instrument flow rate versus design flow rate 1.13 m 3 /min (PM10 only) o >5% - consider corrective maintenance or recalibration o >10% - the data bracketed by the check should be considered for invalidation Temperature agreement between certified standard and sensor reading o > 4 C consider recalibrating the temperature sensor Barometric Pressure o > 10 mm Hg consider recalibrating the pressure sensor

5 Volumetric Controlled High Volume Samplers Principle: Volumetric controlled high volume samplers are controlled by a choked flow venturi. This venturi approximately limits the flow to a design value so long as there is a sufficient vacuum being drawn. The flow rate is slightly dependent on temperature and the pressure ratio before and after the venturi. A lookup table is provided specific to each venturi device or a temperature/pressure dependent equation may be used in some cases to determine the actual flow rate of the sampler. It is the opinion of WDNR that this method of flow determination is more accurate than a Dickson chart calibration and reading. Calibration: Since the venturi is a fixed device, there is no calibration of the sampler flow rate. Instead, the user performs a flow check to verify the sampler is operating properly. It is recommended that at startup and annually a multipoint check should be done with no filter in place and a variety of stagnation pressures bracketing the normal operating stagnation pressure by approximately 5 inches of pressure (if normal stagnation pressure is 19 inches check five points from inches of pressure). If the results of the check are poor (>5%), it is an indication of a problem with sampler such as a leak, or a weak motor not pulling enough vacuum. Monthly: A one point flow check should be conducted monthly by the site operator. This check should be done with a filter in place, or no filter and an orifice adjusted to produce a similar stagnation pressure typically seen pre and post sampling. This check should be done using an orifice calibrated in actual conditions and taking measurements with a certified temperature and pressure standard. The flow measured using the orifice should be compared to the flow that would be determined using the venturi lookup table or equation using the same temperature and pressure. Audit: An annual audit will be conducted by WDNR personnel with an independent flow standard in an identical fashion to the suggested monthly check. An audit will pass if the 7% and 10% flow rate invalidation criteria are not exceeded. If either of these conditions is exceeded, work will be done to try to determine the cause of the problem including cross checking the flow rate with the facility orifice, if available.

6 Mass Flow Controlled High Volume Samplers Principle: Mass flow controlled high volume samplers are typically controlled by an automated mass flow controller (MFC). The MFC automatically varies the motor voltage and consequently the standard flow rate of the sampler. Some TSP units use a rheostat which is manually set to deliver a specific voltage to the motor. The sampling flow rate is measured and recorded by a calibrated Dickson chart recorder. Calibration: A multipoint calibration should be done at startup and after any maintenance that may affect flow rate. WDNR recommends that operators utilize the calibration procedure provided in EPA Method IO-2.1I at or the method recommended by the equipment manufacturer. This method typically uses an orifice calibrated in actual conditions and compares the measured flow rates to Dickson readings and developing a linear relationship between the two. A certified temperature and pressure standard should be used during this procedure. After the calibration is completed, a one point check at the operational flow rate is recommended to confirm the calibration and instrument setting is acceptable. Monthly: A one point flow check should be conducted monthly by the site operator. This check should be done with a filter in place and the mass flow controller or rheostat inline. This check should be done using an orifice calibrated in actual conditions fully open or with no restrictor plate and taking measurements with a certified temperature and pressure standard. The flow measured using the orifice is compared to the flow that would be calculated from the Dickson chart reading using the same temperature and pressure. PM10 Audit: An annual audit will be conducted by WDNR personnel with an independent flow standard in an identical fashion to the suggested monthly check. An audit will pass if the 7% and 10% flow rate invalidation criteria are not exceeded. If either of these conditions is exceeded, work will be done to try to determine the cause of the problem including cross checking the flow rate with the facility orifice, if available. TSP Audit: An annual audit will be conducted by WDNR personnel with an independent flow standard. This audit will consist of taking the mass flow controller or rheostat out of line. No filter is used for this audit. Five points are run with either a variable orifice or fixed orifice and plates. Flow rates should bracket the operational range (approximately 1.1 to 1.7 m 3 /min). For each point the flow measured using the orifice is compared to the flow that would be calculated from the Dickson chart reading using the same temperature and pressure. An audit will pass as long as the overall percent difference is within 7%.

7 Computer Controlled High Volume Samplers Principle: Computer controlled high volume samplers have integrated pressure and temperature sensors as well as a computer that acts as a timer control and directly provides flow and volume measurements in both actual and standard conditions to the user as well as other sampling event information. The flow control can either utilize a mass flow controller or choked flow venturi which may be transparent to the operator. This type of sampler is capable of automatically performing checks and calibrations. Currently, WDNR has limited direct experience with computer controlled high volume samplers. For this reason, WDNR recommends performing occasional manual checks to verify all components of the sampler are functioning correctly. The sampler should be set up to control the flow in actual conditions but standard sample volumes should be used for determining reporting ambient particulate concentrations. Calibration: WDNR recommends that users follow the method recommended by the equipment manufacturer. This method typically uses an orifice calibrated in actual conditions with the pressure tap plugged into a pressure sensor. The computer runs a calibration sequence and calculates slope and intercept flow settings. It is recommended that the barometric pressure and temperature sensors be checked and calibrated as needed using certified standards. Calibrations should be done after any major maintenance including motor changes. Monthly: A manual one point flow check should be conducted monthly by the site operator. This check should be done with a filter in place. This check should be done using an orifice calibrated in actual conditions fully open or with no restrictor plate and taking measurements with a certified temperature and pressure standard. The orifice pressure should be read by a manometer or certified pressure standard instead of the computer. The flow measured using the orifice should be compared to the actual flow displayed by the computer. Additionally the orifice flow should be converted to standard conditions and compared to the standard flow measured by the computer or converted from the actual flow using the sampler s temperature and pressure readings and checked to see if it meets the 7% criteria. It is suggested that temperature and pressure sensors are also checked against certified standards. Audit: An annual audit will be conducted by WDNR personnel with an independent flow standard in an identical fashion to the suggested monthly check. An audit will pass if the 7% and 10% flow rate invalidation criteria are not exceeded. If either of these conditions is exceeded, work will be done to try to determine the cause of the problem including cross checking the flow rate with the facility orifice, if available.

APPENDIX E. Fourth Quarter 2009 EFR Ambient Air Systems Calibration Report

APPENDIX E. Fourth Quarter 2009 EFR Ambient Air Systems Calibration Report APPENDIX E Fourth Quarter 2009 EFR Ambient Air Systems Calibration Report AMBIENT AIR SYSTEMS CALIBRATION REPORT - FOURTH QUARTER 2009 ENERGY FUELS RESOURCES CORPORATION URANIUM MILL LICENSING SUPPORT

More information

Air Pollution Control Division. Technical Services Program

Air Pollution Control Division. Technical Services Program Page 1 of 10 Air Pollution Control Division Technical Services Program APPENDIX PM4 STANDARD OPERATING PROCEDURE FOR THE DETERMINATION OF PM 10 AND PM 2.5 IN AMBIENT AIR USING A GRIMM EDM 180 Page 2 of

More information

Iowa Fine Particulate Monitoring Network Design Values 2011-2013. Iowa DNR Ambient Air Monitoring Group

Iowa Fine Particulate Monitoring Network Design Values 2011-2013. Iowa DNR Ambient Air Monitoring Group Iowa Fine Particulate Monitoring Network Design Values 2011-2013 Iowa DNR Ambient Air Monitoring Group What is Fine Particulate Matter (PM 2.5 )? The term particulate matter (PM) includes both solid particles

More information

DIVISION OF ENVIRONMENT QUALITY MANAGEMENT PLAN PART III: AMBIENT AIR MONITORING STANDARD OPERATING PROCEDURES. Revision 3.

DIVISION OF ENVIRONMENT QUALITY MANAGEMENT PLAN PART III: AMBIENT AIR MONITORING STANDARD OPERATING PROCEDURES. Revision 3. DIVISION OF ENVIRONMENT QUALITY MANAGEMENT PLAN PART III: AMBIENT AIR MONITORING STANDARD OPERATING PROCEDURES Revision 3 February 8, 2011 Kansas Department of Health and Environment Division of Environment

More information

August 31, 2010 Revision: 1. Energy Fuels Resources Corporation Prepared By: 44 Union Boulevard, Suite 600 Lakewood, Colorado 80228

August 31, 2010 Revision: 1. Energy Fuels Resources Corporation Prepared By: 44 Union Boulevard, Suite 600 Lakewood, Colorado 80228 SECOND QUARTER 2009 DATA REPORT FOR AMBIENT AIR MONITORING ENERGY FUELS RESOURCES CORPORATION URANIUM MILL LICENSING SUPPORT PIÑON RIDGE MILL MONTROSE COUNTY, COLORADO August 31, 2010 Revision: 1 Energy

More information

RITTER Multiple Sonic Nozzle Calibration System

RITTER Multiple Sonic Nozzle Calibration System RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases

More information

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002 First Edition MONITORING AND LABORATORY DIVISION August

More information

11.0 Instrument Equipment Testing, Inspection and Maintenance

11.0 Instrument Equipment Testing, Inspection and Maintenance Page 1 of 6 11.0 Instrument Equipment Testing, Inspection and Maintenance Implementing an ambient air monitoring network, with the various types of equipment needed, is no easy task. Through appropriate

More information

6 H2O + 6 CO 2 (g) + energy

6 H2O + 6 CO 2 (g) + energy AEROBIC RESPIRATION LAB DO 2.CALC From Biology with Calculators, Vernier Software & Technology, 2000. INTRODUCTION Aerobic cellular respiration is the process of converting the chemical energy of organic

More information

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques Introduction The amount of dissolved oxygen in process water is continually gaining importance in many industries as a critical parameter

More information

Spreadsheet Program for EPA Method 202 Condensible Particulate Matter Emission Rate and Concentration Calculations

Spreadsheet Program for EPA Method 202 Condensible Particulate Matter Emission Rate and Concentration Calculations Spreadsheet Program for EPA Method 202 Condensible Particulate Matter Emission Rate and Concentration Calculations This spreadsheet calculates flue gas concentrations of condensible particulate matter(cpm)

More information

Quality Assurance Program Quality Assurance Plan Periodic Audits Standard Operating Procedures Preventive Maintenance Outline Quality Assurance Plan (QAP) What is a QAP Why is a QAP required? What does

More information

Life & Times of a PM2.5 Filter: Quality Control in the Laboratory and Beyond

Life & Times of a PM2.5 Filter: Quality Control in the Laboratory and Beyond Life & Times of a PM2.5 Filter: Quality Control in the Laboratory and Beyond Brenda Saldana, Manager Inorganic Laboratory Section Monitoring and Laboratory Division Air Resources Board 1 Field Sampling

More information

How To Order A Direct Flow Air Cleaner

How To Order A Direct Flow Air Cleaner Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

User s Manual Laminar Flow Elements

User s Manual Laminar Flow Elements 501:440-13 User s Manual Laminar Flow Elements 10920 Madison Avenue Cleveland, Ohio 44102 Tel: 216.281.1100 email:meriam@meriam.com Web:www.meriam.com 1 TABLE OF CONTENTS Subject Page Introduction... 3

More information

1.0 What Are the Purpose and Applicability of Performance Specification 11?

1.0 What Are the Purpose and Applicability of Performance Specification 11? While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the

More information

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER FLOW MEASUREMENT 200 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER Dr D G Stewart, NEL Dr M Reader-Harris, NEL Dr R J W Peters, McCrometer Inc INTRODUCTION The V-Cone

More information

TR 07-03 SUPPLEMENTARY REQUIREMENTS FOR THE ACCREDITATION OF CONTINUOUS AMBIENT AIR QUALITY MONITORING STATIONS

TR 07-03 SUPPLEMENTARY REQUIREMENTS FOR THE ACCREDITATION OF CONTINUOUS AMBIENT AIR QUALITY MONITORING STATIONS SUPPLEMENTARY REQUIREMENTS FOR THE ACCREDITATION OF CONTINUOUS AMBIENT AIR QUALITY MONITORING STATIONS Approved By: Chief Executive Officer: Ron Josias Senior Manager: Christinah Leballo Reviewed By: Testing

More information

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering

More information

AQS Site and Monitor Configuration

AQS Site and Monitor Configuration AQS Site and Monitor Configuration AQS How-To Clinic Site & Monitor Configuration National Ambient Air Monitoring Conference August 2014 1 Site and Monitor Metadata Site Basic Site Info (AA) Site Street

More information

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration

More information

Sentinel I28 and Blackbelt Mass Flow Calibration and Verification

Sentinel I28 and Blackbelt Mass Flow Calibration and Verification Service Bulletin: #001 Date: August 2012 Sentinel I28 and Blackbelt Mass Flow Calibration and Verification Summary This Application Bulletin will give a short synopsis of the purpose of a calibration and

More information

S-SERIES COMBINE CALIBRATION GUIDE CLICK THE ARROW TO GET STARTED

S-SERIES COMBINE CALIBRATION GUIDE CLICK THE ARROW TO GET STARTED S-SERIES COMBINE CALIBRATION GUIDE CLICK THE ARROW TO GET STARTED 1. TEMPERATURE CALIBRATION Temperature calibration should be performed when the sensor has not been in direct sunlight or filled with grain,

More information

QA Transactions and Reports

QA Transactions and Reports QA Transactions and Reports Monitoring Quality Assurance QA Transactions & Reports National Ambient Air Monitoring Conference August 2014 1 Background The QA requirements for ambient air quality monitoring

More information

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural

More information

DISSOLVED OXYGEN PROBE

DISSOLVED OXYGEN PROBE 51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe

More information

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08 Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.

More information

National Environment Protection (Ambient Air Quality) Measure

National Environment Protection (Ambient Air Quality) Measure National Environment Protection (Ambient Air Quality) as amended made under section 20 of the National Environment Protection Council Act 1994 (Cwlth), National Environment Protection Council (New South

More information

Custody Transfer Measurement. with the V-Cone Flowmeter

Custody Transfer Measurement. with the V-Cone Flowmeter Custody Transfer Measurement with the V-Cone Flowmeter Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the approval of the McCrometer V-Cone flowmeter for custody

More information

PM Fine Database and Associated Visualization Tool

PM Fine Database and Associated Visualization Tool PM Fine Database and Associated Visualization Tool Steven Boone Director of Information Technology E. H. Pechan and Associates, Inc. 3622 Lyckan Parkway, Suite 2002; Durham, North Carolina 27707; 919-493-3144

More information

ATTACHMENT 8: Quality Assurance Hydrogeologic Characterization of the Eastern Turlock Subbasin

ATTACHMENT 8: Quality Assurance Hydrogeologic Characterization of the Eastern Turlock Subbasin ATTACHMENT 8: Quality Assurance Hydrogeologic Characterization of the Eastern Turlock Subbasin Quality assurance and quality control (QA/QC) policies and procedures will ensure that the technical services

More information

Precision Mass Flow Metering For CVD Applications.

Precision Mass Flow Metering For CVD Applications. Precision Mass Flow Metering For CVD Applications. Ir. H.J. Boer Research Department of Bronkhorst High-Tech B.V. Nijverheidsstraat 1A, 7261 AK Ruurlo The Netherlands. Tel: +31 (0)573 458800 Fax: +31 (0)573

More information

CONTINUOUS MONITORING MANUAL. DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION 811 SW SIXTH AVENUE Portland, Oregon 97204

CONTINUOUS MONITORING MANUAL. DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION 811 SW SIXTH AVENUE Portland, Oregon 97204 CONTINUOUS MONITORING MANUAL DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION 811 SW SIXTH AVENUE Portland, Oregon 97204 January 23, 1992 Table of Contents 1.0 INTRODUCTION... 1 2.0 DEFINITIONS...

More information

Technical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements

Technical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements Technical & Sizing Bulletin for Meriam LFEs Laminar Flow Elements What they are... Meriam Laminar Flow Elements are gas volume rate of flow differential producers operating on capillary flow principles.

More information

Quality System Training Module 4 Data Validation and Usability

Quality System Training Module 4 Data Validation and Usability Quality System Training Module 4 Data Validation and Usability Dennis Mikel EPA - Office of Air Quality Planning and Standards 2008 Conference on Managing Environmental Quality Systems Some Definitions

More information

Standard Operating Procedure for Database Operations

Standard Operating Procedure for Database Operations PM 2.5 Diltabase Operations Date: May 8 2008 Page I of 18 Standard Operating Procedure for Database Operations Environmental Health and Safety Division RTl lnternational* Research Triangle Park, North

More information

Particle Size Distribution Analysis of Cotton Gin Dust and Its Impact on PM 10 Concentration Measurements

Particle Size Distribution Analysis of Cotton Gin Dust and Its Impact on PM 10 Concentration Measurements Particle Size Distribution Analysis of Cotton Gin Dust and Its Impact on PM 1 Concentration Measurements Sergio C. Capareda 1, Michael D. Buser 2, Derek Whitelock 3, J. Kelley Green 4, Calvin B. Parnell,

More information

Effects of Atmospheric Pressure on Gas Measurement

Effects of Atmospheric Pressure on Gas Measurement Effects of Atmospheric Pressure on Gas Measurement Class # 1390.1 March 2012 / White paper by Denis Rutherford Regional Sales Manager Central US Schneider Electric Telemetry & Remote SCADA Solutions 6650

More information

DATA VALIDATION, PROCESSING, AND REPORTING

DATA VALIDATION, PROCESSING, AND REPORTING DATA VALIDATION, PROCESSING, AND REPORTING After the field data are collected and transferred to your office computing environment, the next steps are to validate and process data, and generate reports.

More information

Quality Assurance Guidance Document 2.12

Quality Assurance Guidance Document 2.12 United States Human Exposure and Atmospheric Sciences Division Environmental Protection National Exposure Research Laboratory Agency Research Triangle Park NC 27711 Research and Development November 1998

More information

Micro Motion Net Oil Computer Software and NOC System

Micro Motion Net Oil Computer Software and NOC System Instruction Manual P/N 20006444, Rev. A May 2007 Micro Motion Net Oil Computer Software and NOC System Configuration and Use Manual 2007, Micro Motion, Inc. All rights reserved. ELITE and ProLink are registered

More information

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS

A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS Presented 2006 May 16-18 2006 ISFFM Queretaro, Mexico A PRIMARY CALIBRATION SYSTEM FOR THE SUPPORT OF HIGH PERFORMANCE GAS FLOW TRANSFER STANDARDS P. Delajoud, M. Bair, C. Rombouts, M. Girard DH Instruments,

More information

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter 2 Table of Contents Abstract... 3 Pressure Fundamentals... 3 Applications...

More information

OVERVIEW OF STANDARD 7E & STANDARD 20

OVERVIEW OF STANDARD 7E & STANDARD 20 Standard for Thermal Transport Packaging Used in Parcel Delivery System Shipment 7E 2 010 ISTA 7E Usage Modes VERSION DATE OCTOBER 2010 Initial Release ISTA, Distributing Confidence, Worldwide ISTA 7-Series

More information

Healthcare Solutions Room Pressure Monitors and Controls

Healthcare Solutions Room Pressure Monitors and Controls Healthcare Solutions s and Controls TOUCHSCREEN ROOM PRESSURE MONITOR The Touchscreen Room Pressure Monitor (PMT) provides precise room pressure monitoring for critical spaces such as isolation rooms,

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

EQUIPMENT CALIBRATION/MAINTENANCE

EQUIPMENT CALIBRATION/MAINTENANCE EQUIPMENT CALIBRATION/MAINTENANCE The following chart provides a guide for calibration of standard equipment used in the Fish Health Laboratory. All Intervals suggested are subject to individual manufacturer

More information

Flow Measurement Options for Pipeline and Open Channel Flow

Flow Measurement Options for Pipeline and Open Channel Flow Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center

More information

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation Ohio Medical Corporation 1111 Lakeside Drive Gurnee, IL 60031 Phone: (800) 448-0770 Fax: (847) 855-6304 info@ohiomedical.com

More information

TransCity Legacy Way Air Monitoring Network

TransCity Legacy Way Air Monitoring Network Accredited for compliance with ISO/IEC 17025. Accreditation No. 14184. TransCity Legacy Way Air Monitoring Network Ambient Air Quality Monitoring Validated Report 1 st June 2015 30 th June 2015 Report

More information

Straight Talk On Tanks Leak Detection Methods For Petroleum Underground Storage Tanks And Piping

Straight Talk On Tanks Leak Detection Methods For Petroleum Underground Storage Tanks And Piping Straight Talk On Tanks Leak Detection Methods For Petroleum Underground Storage Tanks And Piping Printed on Recycled Paper Contents Do You Have Questions About Leak Detection?...1 An Overview Of Leak Detection

More information

Thermal Dispersion Mass Flow

Thermal Dispersion Mass Flow Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6

More information

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM ETV JOINT VERIFICATION STATEMENT TECHNOLOGY TYPE: APPLICATION: TECHNOLOGY NAME: COMPANY: BAGHOUSE FILTRATION PRODUCTS CONTROL OF PM 2.5 EMISSIONS BY BAGHOUSE

More information

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB

More information

TSA of TCEQ Air Monitoring Program Austin, Texas September 7-28, 2010

TSA of TCEQ Air Monitoring Program Austin, Texas September 7-28, 2010 TSA of TCEQ Air Monitoring Program Austin, Texas September 7-28, 2010 An on-site evaluation of the TCEQ Air Monitoring Program was conducted on September 7 th through September 28 th, 2010. The previous

More information

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction

More information

VISIBLE EMISSIONS TRAINING AND CERTIFICATION PROGRAM EVALUATION FORM

VISIBLE EMISSIONS TRAINING AND CERTIFICATION PROGRAM EVALUATION FORM VISIBLE EMISSIONS TRAINING AND CERTIFICATION PROGRAM EVALUATION FORM Good management practice requires that every visible emission training (VETC) program activity be periodically reviewed and evaluated

More information

Meter Technician Certification Exam

Meter Technician Certification Exam Meter Technician Certification Exam Revised September 2012 Version 12.0 This exam is designed to test the knowledge of meter technicians in order to attain certification to check the calibration of portable

More information

Technical Bulletin 144. Air Volume Conversions. by:

Technical Bulletin 144. Air Volume Conversions. by: Technical Bulletin 144 Air Volume Conversions by: Environmental Dynamics International Published: 4/2007 DISCLAIMER Technical Bulletins are presented as a service by Environmental Dynamics International

More information

The Ambient Air Monitoring System

The Ambient Air Monitoring System The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters

More information

Best Practices for Reducing Transmitter Life Cycle Costs

Best Practices for Reducing Transmitter Life Cycle Costs Best Practices for Reducing Transmitter Life Cycle Costs RESULTS Eliminate on-site calibration and lower total installed costs by purchasing calibrated transmitters Eliminate unnecessary calibration and

More information

Flow System Calibration in Medical and Bio-medical Production Processes.

Flow System Calibration in Medical and Bio-medical Production Processes. Flow System Calibration in Medical and Bio-medical Production Processes. Speaker / Author: Mark Finch Fluke Calibration Norfolk, Norwich, NR6 6JB, UK e-mail: mark.finch@fluke.com Phone: + 44 (0)1908 678

More information

Data Quality Assurance and Control Methods for Weather Observing Networks. Cindy Luttrell University of Oklahoma Oklahoma Mesonet

Data Quality Assurance and Control Methods for Weather Observing Networks. Cindy Luttrell University of Oklahoma Oklahoma Mesonet Data Quality Assurance and Control Methods for Weather Observing Networks Cindy Luttrell University of Oklahoma Oklahoma Mesonet Quality data are Trustworthy Reliable Accurate Precise Accessible Data life

More information

System Diagnosis. Proper vehicle diagnosis requires a plan before you start

System Diagnosis. Proper vehicle diagnosis requires a plan before you start System Diagnosis Proper vehicle diagnosis requires a plan before you start Following a set procedure to base your troubleshooting on will help you find the root cause of a problem and prevent unnecessary

More information

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India Establishment of the Gas Flow Calibration Facility at CSIR-PL, India Speaker: Shiv Kumar Jaiswal Fluid Flow Measurement Standards CSIR-ational Physical Laboratory (PLI) Dr. K.S. Krishnan Road ew Delhi

More information

Montana Ambient Air Monitoring Program Quality Management Plan

Montana Ambient Air Monitoring Program Quality Management Plan Montana Ambient Air Monitoring Program Quality Management Plan September 15, 2015 State of Montana Ambient Air Monitoring Program Montana Department of Environmental Quality Air Quality Bureau 1520 E.

More information

Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program

Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program Data Quality Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program Why do we care? Program goals are key what do you want to do with the data? Data utility increases directly

More information

Certificate: 0000040216 / 29 April 2014

Certificate: 0000040216 / 29 April 2014 Test report: 936/21209885/G of 20 September 2013 Initial certification: 01 April 2014 Date of expiry: 31 March 2019 Publication: BAnz AT 01 April 2014 B12, chapter IV, No. 7.3 Approved application The

More information

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL

TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL Project No. 148 TEST REPORT for the ARID TECHNOLOGIES VAPOR RECOVERY UNIT installed in LANTANA, FL Prepared for: Mr. Ted Tiberi Arid Technologies, Inc. 130 North LaGrange Rd. LaGrange, IL 60525 Prepared

More information

NSW Air Quality Monitoring Network: Quality Assurance Procedures

NSW Air Quality Monitoring Network: Quality Assurance Procedures NSW Air Quality Monitoring Network: Quality Assurance Procedures Copyright State of NSW and Office of Environment and Heritage With the exception of photographs, the State of NSW and Office of Environment

More information

Technical Note- Use of Electronic Logbooks for Ambient Air Monitoring 04/20/2016

Technical Note- Use of Electronic Logbooks for Ambient Air Monitoring 04/20/2016 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY RESEARCH TRIANGLE PARK, NC 27711 OFFICE OF AIR QUALITY PLANNING AND STANDARDS Technical Note- Use of Electronic Logbooks for Ambient Air Monitoring 04/20/2016

More information

Throttle Body Fuel Injection

Throttle Body Fuel Injection Throttle Body Fuel Injection Initial Calibration of the TBI Disclaimer The author of this presentation assumes NO responsibility for information provided causing the owner to modify or alter their motorhome

More information

Fiscal Measurement Natural Gas

Fiscal Measurement Natural Gas White Paper FSG-WP-0012 February 2014 Fiscal Measurement Natural Gas Fiscal Measurement How much? Fiscal Measurement must not be confused with Custody Transfer; in fact, fiscal measurement is a more general

More information

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as

More information

APPENDIX AVAILABLE ON REQUEST. Research Report 154

APPENDIX AVAILABLE ON REQUEST. Research Report 154 APPENDIX AVAILABLE ON REQUEST Research Report 154 Part 2. Association of Daily Mortality with Ambient Air Pollution, and Effect Modification by Extremely High Temperature in Wuhan, China Zhengmin Qian

More information

119536-P1 Rev A, 4/97. MKS Type 1153A Low Vapor Pressure Source Mass Flow Controller

119536-P1 Rev A, 4/97. MKS Type 1153A Low Vapor Pressure Source Mass Flow Controller 119536-P1 Rev A, 4/97 MKS Type 1153A Low Vapor Pressure Source Mass Flow Controller Copyright 1997 by MKS Instruments, Inc. All rights reserved. No part of this work may be reproduced or transmitted in

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

ENERGY AUDITS AND RETRO- COMMISSIONING Local Law 87

ENERGY AUDITS AND RETRO- COMMISSIONING Local Law 87 ENERGY AUDITS AND RETRO- COMMISSIONING Local Law 87 Overview Although energy-efficiency retrofits generally result in major cost and energy savings, many buildings are not participating in the audits that

More information

Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1

Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1 Designation: D 4820 99 Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1 This standard is issued under the fixed designation D 4820; the number immediately

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Ambient Pressure = and Pressure, collectively

Ambient Pressure = and Pressure, collectively Three in One Pressure: Ambient, Barometric, Atmospheric 1 Ambient Pressure Overhead Transparency Ambient Pressure = and Pressure, collectively When surrounded by air, pressure =? pressure =? pressure The

More information

Calibrating Differential Pressure Sensors

Calibrating Differential Pressure Sensors Calibrating Differential Pressure Sensors Additel Corporation 22865 Savi Ranch Parkway, Ste F Yorba Linda, CA 92887 Introduction Differential pressure sensors are common in the process industry and cover

More information

Designing Gain and Offset in Thirty Seconds

Designing Gain and Offset in Thirty Seconds Application Report SLOA097 February 2002 Designing Gain and Offset in Thirty Seconds Bruce Carter High Performance Linear ABSTRACT This document discusses how to design an operational amplifier (op amp)

More information

Emission monitoring, reporting, and verification (MRV) for U.S. cap and trade programs. Jeremy Schreifels US EPA

Emission monitoring, reporting, and verification (MRV) for U.S. cap and trade programs. Jeremy Schreifels US EPA Emission monitoring, reporting, and verification (MRV) for U.S. cap and trade programs Jeremy Schreifels US EPA Principles of MRV for cap and trade programs Cap & trade requires a complete record of total

More information

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200

More information

Validation of process gas systems

Validation of process gas systems Validation of Process Gas Systems By Jeff Hargroves Alza Corporation Validation of process gas systems involve documenting the expected system behavior, and verifying that the system performs as expected.

More information

Chapter 2 Compliance Branch CEMS Guidance Manual Table of Contents. Applicability... 1.0

Chapter 2 Compliance Branch CEMS Guidance Manual Table of Contents. Applicability... 1.0 Chapter 2 Compliance Branch CEMS Guidance Manual Table of Contents Page No. Applicability... 1.0 1.0 Continuous Emissions Monitor Operating Principles... 3.0 1.1 Introduction... 3.0 1.2 Definitions...

More information

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi, Lecture 14 Flow Measurement in Pipes I. Elbow Meters An elbow in a pipe can be used as a flow measuring device much in the same way as a venturi or orifice plate The head differential across the elbow

More information

Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of

More information

Metrological features of a beta absorption particulate air monitor operating with wireless communication system

Metrological features of a beta absorption particulate air monitor operating with wireless communication system NUKLEONIKA 2008;53(Supplement 2):S37 S42 ORIGINAL PAPER Metrological features of a beta absorption particulate air monitor operating with wireless communication system Adrian Jakowiuk, Piotr Urbański,

More information

1. Standard conditions are 29.92 in. Hg (760 mm Hg, 14.696 psia) and 68 F (20 C).

1. Standard conditions are 29.92 in. Hg (760 mm Hg, 14.696 psia) and 68 F (20 C). INTRODUCTION Emission Monitoring Inc. DETERMINING F-FACTORS FROM GAS CHROMATOGRAPHIC ANALYSES Roger T. Shigehara Emission Monitoring Incorporated Howard F. Schiff TRC Environmental Corporation EPA Method

More information

Learning Objectives. History of Vacuum Testing for Precast. Vacuum Testing. Terminology and purpose

Learning Objectives. History of Vacuum Testing for Precast. Vacuum Testing. Terminology and purpose : It Just Sucks! Presented by: Darryl Cloud Concrete Sealants, Inc. Learning Objectives In this course, you will learn: Terminology for Watertightness Equipment Tips, Tricks, and FAQ s History of Vacuum

More information

POLE MOUNT SYSTEM-3 INSTALLATION

POLE MOUNT SYSTEM-3 INSTALLATION 1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only

More information

MILLIKEN CLEAN COAL TECHNOLOGY DEMONSTRATION PROJECT UNIT 2 ELECTROSTATIC PRECIPITATOR PERFORMANCE TEST RESULTS BEFORE AND AFTER MODIFICATION

MILLIKEN CLEAN COAL TECHNOLOGY DEMONSTRATION PROJECT UNIT 2 ELECTROSTATIC PRECIPITATOR PERFORMANCE TEST RESULTS BEFORE AND AFTER MODIFICATION MILLIKEN CLEAN COAL TECHNOLOGY DEMONSTRATION PROJECT UNIT 2 ELECTROSTATIC PRECIPITATOR PERFORMANCE TEST RESULTS BEFORE AND AFTER MODIFICATION Prepared by: CONSOL Inc. Research & Development 4000 Brownsville

More information

THE LABORATORY NOTEBOOK

THE LABORATORY NOTEBOOK THE LABORATORY NOTEBOOK In scientific work keeping a permanent record of all raw data, observations, calculations, et cetera obtained during an experiment is important. Therefore, a student must become

More information

Source Sampling Manual Volume II

Source Sampling Manual Volume II Source Sampling Manual Volume II December, 1980 Revisions: May, 1981 January, 1992 April, 2015 Operations Division 811 SW 6 th Avenue Portland, OR 97204 Phone: 503-229-5696 800-452-4011 Fax: 503-229-5850

More information

Appendix A Contractor Quality Control Plan The Contractor Quality Control Plan is the Contractor s management plan for executing the contract.

Appendix A Contractor Quality Control Plan The Contractor Quality Control Plan is the Contractor s management plan for executing the contract. Appendix A Contractor Quality Control Plan The Contractor Quality Control Plan is the Contractor s management plan for executing the contract. The Contractor QCP describes the way in which the Contractor

More information

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

TÜV RHEINLAND ENERGIE UND UMWELT GMBH TÜV RHEINLAND ENERGIE UND UMWELT GMBH Report on performance testing of the Air Pollution Monitor 2 (APM-2) measuring system manufactured by Comde-Derenda GmbH for the components suspended particulate matter

More information